TRUSCOPE ultra Q7/ Q5/ Q3


15”/ 12.1”/ 10.4” Modular Patient Monitors

Features:
 Q7: 15" / Q5: 12.1" / Q3: 10.4" touchscreen colour
TFT LCD display
 Upto 7 lead ECG display (12 lead display optional)
 Total 10 waveform display simultaneously
 8 different screen configurations
 ST & Arrhythmia analysis
 Drug dose, hemodynamic, renal profile (nephridium),
& oxygenation calculations
 OXY CRG software
 External video (VGA) output
 168 hours graphical and tabular trends
 SD card facility for data storage
 Non - Volatile memory
 Central Monitoring System : Wired
TRUSCOPE ® ultraQ7/Q5/Q3

TRUSCOPE ultra - Q7

Optional

Central Monitoring System : Wi-fi


Thermal Recorder

®
TRUSCOPE ultra - Q7
15” Modular Patient Monitor

Optional modular upgrades


TRUSCOPE ultra- Q5

ETCO2 ( Mainstream / Sidestream / Microstream )


Multigas monitoring
Cardiac Output - Thermodilution
12 lead ECG
Dual IBP
Nellcor or Masimo SpO2
Wi-fi module for wireless data transmission

®
TRUSCOPE ultra - Q5
12.1” Modular Patient Monitor

Preconfigured configuration available r - Q3


TRUSCOPE ulta

Five parameters: ECG, RR, SpO2 (Digital), 2Temp, NIBP


Optional: 2IBP, SpO2 (Nellcor / Masimo)

®
TRUSCOPE ultra - Q3
10.4” Modular Patient Monitor
Invasive Cardiac Output (Thermodilution)

Method : Invasive
Measurement range:
- CO range : 0.1 to 20 L/min
- CO resolution : 0.1 L/min
Injectate volume : 0 to 10 ml
Range Accuracy Injectate temperature : 1 to 27° C
0 to 15% + (0.3 kPa + 4% of reading) Accuracy : ± 2%
0 to 100% + (2 kPa + 2% of reading)
0 to 100% + (2 kPa + 5% of reading)
0 to 8% + (0.2 kPa + 10% of reading)
0 to 10% + (0.2 kPa + 10% of reading)
0 to 22% + (0.2 kPa + 10% of reading)
®
TRUSCOPEultraQ7/Q5/Q3
Technical Data
General Respiration
Size & Weight Method : Thoracic impedance
- Size : Q7: 335 mm X 366 mm X 172 mm Lead selected from : I(RA-LA) or II (RA-LL); Default : 11
Q5 / Q3: 318 mm X 264 mm X 152 mm Gain : x0.25, x1, x2, x4
- Weight : Q7: < 6 kg Bandwidth : 0.25 Hz to 2.0 Hz (-3db)
Q5 / Q3: < 4.5 kg Sweep Speed : 6.25 mm/s, 12.5 mm/s, 25 mm/s
- Standard module slot : Q7: 3 Measurement range : 0~150 rpm
Q5 / Q3: 2 Resolution : 1 rpm
- Power supply
Accuracy : ±2 rpm or 2% whichever is greater
- Power voltage : AC 100-240V 50/60 Hz
Delay Apnea Alarm : 10s, 15s, 20s, 25s, 30s,35s,
- Input current : Q7:1.7 A to 0.8 A
40s, 45s,50s, 55s, 60s
Q5 / Q3: 1.1 A to 0.5 A NIBP
- Safety class : Category I
Display Measurement method : Automatic Oscillometry
- Q7 : 15” / Q5: 12.1” / Q3: 10.4” Color TFT - LCD Range of measurement :
- Resolution : Q7: 768 X 1024 pixels Adult : SYS 30~270 mmHg
Q5 / Q3: 800 x 600 pixels DIA 10~220 mmHg
Battery MAP 20~235 mmHg
- Type : Rechargeable lithium-ion battery Child : SYS 30~235 mmHg
- Q5/Q3 : Operating time under the normal use and DIA 10~220 mmHg
full charge > 210 minutes  MAP 20~225 mmHg
- Q7: Operating time under the normal use and Neonate : SYS 30~135 mmHg
full charge > 120 minutes (2 batteries for 240 minutes) DIA 10~100 mmHg
Recorder (Optional) MAP 20~125 mmHg
- Method : Thermal dot array Cuff pressure range : 0~280 mmHg
- Paper width : 50 mm (1.97 in) Resolution : 1 mmHg
- Paper speed : 12.5 / 25 / 50 (mm/sec) Pressure accuracy : Static : ±2% or ±3 mmHg
- Traces : Maximum 3 tracks Clinical : ±5 mmHg (Average error)
Alarm Standard deviation: <8 mmHg
- Level : Low, medium and high Unit : mmHg, kPa
- Indication : Auditory and visual Measurement mode: Manual, Auto, STAT
- Patient physiological alarm light color : Yellow & Red Intervals for AUTO measurement time :
- Equipment technical alarm light color : Blue 1, 2, 3, 4, 5, 10, 15, 30, 60, 90 minutes; 2, 4, 8 12 hours
- Supports pitch tone and multi-level volume STAT mode cycle time: 5 minutes, at 5 seconds interval
- Supports custom arrthythmia tone Overpressure protection : Hardware and software double
Input device protection
- Touchscreen Pulse rate range : 40~240 bpm
- Knob (only in Q5 / Q3)
- Keyboard input: Support
Digital SpO2
System output & Extensible Inter faces
- Ethernet network : 1 Standard RJ45 socket Measurement range : 0~100%
- Defibrillation output : 1RJ11socket Resolution : 1%
- Nurse call : 1BNC socket Accuracy : At 70~100%, ±2%
- Video output : 1 VGA port At 0~69%, unspecified
- SD memory card : 2GB Pulse rate
- Analog output (ECG or IBP) : (Option) - Measurement range : 20 bpm to 250 bpm
Trend and Reviewing - Resolution : 1 bpm
- Trend data : 168 hours - Accuracy : ±1% or ±1 bpm
- NIBP measurement reviewing : 1000 groups
- ARR event : 128 groups of ARR event and the Nellcor / Masimo SpO2
associate waveform Measurement range : 0~100%
- Alarm events : 128 groups of parameter alarm events Resolution : 1%
and associated parameter Accuracy : 70% to 100 % ; ± 2% (adult)
Environment
- Operating temperature : 0º~40º C
70% to 100 % ; ± 3% (neonate)
- Storage temperature : -20º to +55º C
70% to 100 % ; ± 2% (low perfusion)
- Operating humidity : 15% to 85% (non condensing) Pulse rate 0% to 69 %, unspecified
- Storage humidity : 10% to 93% (non condensing) - Measurement range : 20~300 bpm
- Operating atmospheric pressure : 860 hPa to 1060 hPa - Resolution : 1 bpm
- Storage atmospheric pressure : 500 hPa to 1060 hPa - Accuracy : ± 3 bpm Non motion conditions
Safety ± 5 bpm motion conditions
- IEC60601-1 Approved, CE marking according to MDD93/42/EEC
Temperature
ECG
Channel : 2
Lead mode : 3, 5, 12 leads ECG input(Option) Measurement range : 0.0° C~50.0º C (32° F~122º F)
Lead selection : I, II, III Accuracy : ±0.1° C or ±1° F
I, II, III, aVR, aVL, aVF, V-, Resolution : 0.1º C or 1° F
I, II, III, aVR, aVL, aVF, V1~V6 (Option) Unit : Celsius (º C), Fahrenheit (º F)
Gain : 2.5 mm/mV, 5 mm/mV, 10 mm/mV, 20 mm/mV,
40 mm/mV, Auto Optional modular upgrades
CMRR : Monitor mode >105 dB
Surgery mode > 105 dB ETCO2 (Mainstream / Sidestream / Microstream)
Diagnostic mode > 90 dB Multigas monitoring
Frequency response (-3dB) : Monitor mode 0.5~ 40 Hz Cardiac Output - Thermodilution
Surgery mode 1~25 Hz 12 lead ECG
Diagnostic mode 0.05~150 Hz Dual IBP (Upgradable to 6 measurement channel)
10.100008 10.100008 Ver 2.0

Input impedance : > 5.0 MΩ Nellcor or Masimo SpO2


ECG signal range : ±10.0 mV Wi-fi module for wireless data transmission
Patient leakage current :<10 uA
Standardizing signal : 1mV ±5% Certication
Baseline recovery: <5 sec after defibrillation (Mon or Surg mode)
Indication of electrode separation : Every electrode (exclusive RL)
Protection : Breakdown Voltage 4000 VAC 50/60 Hz; defibrillator proof
Sweep speed :12.5 mm/s, 25 mm/s, 50 mm/s Standard accessories
Heart Rate - Power cord - 1 no.
- ECG cable (5 lead) - 1 no.
Range : Adult 10~300 bpm
- Disposable ECG electrodes - 10 nos.
Pediatric and Neonate 10~350 bpm
- Reusable SpO2 sensor (adult) with
Resolution : 1 bpm
extension cable - 1 no. each
Accuracy : ±1% or ±1 bpm
- Skin temperature probe - 1 no.
ST segment - Rectal temperature probe - 1 no.
- NIBP cuff (Adult & Pediatric) - 1 no. each
Measurement range : -2.0 mV~2.0 mV
- NIBP extension cable - 1 no.
Accuracy : -0.8 mV~0.8 mV, ±0.02 mV or ±10%
- SD memory card (2 GB) - 1 no.
whichever is greater
- Earth cable - 1 no.
Over±0.8 mV unspecified
- User manual - 1 no.
Resolution : 0.01 mV
- Warranty card - 1 no.

Headquarters: SCHILLER AG, Altgasse 68, CH-6341 Baar, Switzerland, Phone +41 41 766 42 42, Fax +41 41 761 08 80, sales@schiller.ch, www.schiller.ch