You are on page 1of 3

Analysis Certificate CALLE 15 No.

34-40, BARRIO PUENTE ARANDA


CODIGO POSTAL 111611, BOGOTA D.C., COLOMBIA
Desde 1985
Calidad controlada a través de análisis TEL: (+57) 1 745-6485
TEL: (+57) 5 671-0860
CEL: (350) 619 - 8084

PROJECT CLIENT: Dominion Global ID TOL - REPORT: 2413


CONTACT ADDRESS: PURCHASE ORDER NO: Pending
EMAIL german.arciniegas@dominion-global.com RECEPTION DATE: September 17, 2020
REQUESTED BY: Ing. Germán Arciniegas REPORT DATE: September 25, 2020

SAMPLE INFORMATION
Crudo – Muestra de Dominion
SAMPLING DATE: NA SAMPLE ID:
Global
TYPE OF CONTAINER: Plastic 1 Gal SAMPLE CODE: 01
GENERAL CONDITIONS: Intact QUANTITY: 0.5 Gal
OBSERVATIONS: NA

1. PLAN AND METHOD OF SAMPLING

The sampling was carried out by the client.

2. RECEIPT, INSPECTION AND STORAGE OF SAMPLE

Summary Photographic Report

The sample was received intact on September 17, 2020.

Dehydration Method
NA
Water and Sediment in Crude Oil by the Centrifuge
Method (Laboratory Procedure) ASTM D4007 – (Initial)
NA
Water in Crude Oils by Potentiometric Karl Fischer
Titration ASTM D4377 (after dehydration)
NA

Quality Management System Certified to ISO 9001:2015, ISO 14001:2015 and ISO 18001:2007
These analyses, opinions or interpretations are based on material supplied by the client to whom, and for whose exclusive and
1 confidential use this report is made. Results related only to the items tested. Texas OilTech Laboratories, L.P. and its officers assume
no responsibility and make no warranty for proper operations of any petroleum, oil, gas or any other material in connection with which this
report is used or relied on. This report may not be reproduced, except in full without prior written approval by Texas OilTech Laboratories,
L.P.
Analysis Certificate CALLE 15 No. 34-40, BARRIO PUENTE ARANDA
CODIGO POSTAL 111611, BOGOTA D.C., COLOMBIA
Desde 1985
Calidad controlada a través de análisis TEL: (+57) 1 745-6485
TEL: (+57) 5 671-0860
CEL: (350) 619 - 8084

PROJECT CLIENT: Dominion Global ID TOL - REPORT: 2413


CONTACT ADDRESS: PURCHASE ORDER NO: Pending
EMAIL german.arciniegas@dominion-global.com RECEPTION DATE: September 17, 2020
REQUESTED BY: Ing. Germán Arciniegas REPORT DATE: September 25, 2020

3. TEST RESULTS
Density, Relative Density, and API Gravity of Crude Oils by Digital Density Meter, ASTM D5002
Parameter Units Result

Specific Gravity @ 60°F 0.9708


API Gravity ° API 14.3
Density @ 60°F g/cm³ 0.9698

Parameter Units Result

Sulfur by X-Ray Fluorescence Spectroscopy. LOD = 0.05, ASTM D4294 Wt % 1.03

Flash Point by Pensky-Martens Closed Cup Tester, ASTM D93 °C 102.6

Water and Sediment in Crude Oil by the Centrifuge Method, ASTM D4007 Vol. % 12%*

Salts in Crude Oil (Electrometric Method), ASTM D3230 PTB 7.9

Acid Number of Petroleum Products by Potentiometric Titration, ASTM D664 mgKOH/g 1.77

Pour Point of Petroleum Products, ASTM D97 °C 0.0

Determination of Carbon Residue (Micro Method), ASTM D4530 Wt. % 10.86

Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic


cSt 1102.9
Viscosity), ASTM D445

Ash from Petroleum Products, ASTM D482 Wt. % 0.37

Sediment by Extraction, ASTM D473 Wt. % 0.083

3.1. Specific environmental conditions of the Tests

Parameter Units Result


Temperature °C 19.31
Humidity % 55.42
* The results are valid only for the sample and trials analyzed. The content of this report cannot be reproduced partially or totally
without authorization from the laboratory.

Quality Management System Certified to ISO 9001:2015, ISO 14001:2015 and ISO 18001:2007
These analyses, opinions or interpretations are based on material supplied by the client to whom, and for whose exclusive and
2 confidential use this report is made. Results related only to the items tested. Texas OilTech Laboratories, L.P. and its officers assume
no responsibility and make no warranty for proper operations of any petroleum, oil, gas or any other material in connection with which this
report is used or relied on. This report may not be reproduced, except in full without prior written approval by Texas OilTech Laboratories,
L.P.
Analysis Certificate CALLE 15 No. 34-40, BARRIO PUENTE ARANDA
CODIGO POSTAL 111611, BOGOTA D.C., COLOMBIA
Desde 1985
Calidad controlada a través de análisis TEL: (+57) 1 745-6485
TEL: (+57) 5 671-0860
CEL: (350) 619 - 8084

PROJECT CLIENT: Dominion Global ID TOL - REPORT: 2413


CONTACT ADDRESS: PURCHASE ORDER NO: Pending
EMAIL german.arciniegas@dominion-global.com RECEPTION DATE: September 17, 2020
REQUESTED BY: Ing. Germán Arciniegas REPORT DATE: September 25, 2020

4. OBSERVATIONS
*The crude has 12% of sediment content and 0% water content.

5. APPLY ADDITIONS, MODIFICATIONS OR EXCLUSIONS OF THE METHOD: YES, NO, X EXPLAIN:


None

Respectfully.
For Texas OilTech Laboratories, L.P.

Edgar Orlando Alba


General Manager - Colombia

Quality Management System Certified to ISO 9001:2015, ISO 14001:2015 and ISO 18001:2007
These analyses, opinions or interpretations are based on material supplied by the client to whom, and for whose exclusive and
3 confidential use this report is made. Results related only to the items tested. Texas OilTech Laboratories, L.P. and its officers assume
no responsibility and make no warranty for proper operations of any petroleum, oil, gas or any other material in connection with which this
report is used or relied on. This report may not be reproduced, except in full without prior written approval by Texas OilTech Laboratories,
L.P.

You might also like