SPM2-FORM-30-001 CATHODIC PROTECTION INSTALLATION REPORT
Page No.: ___ of ___

Company : PT. Pertamina Report No. : xxx/SACP/M/YY

Contractor : PT. Wijaya Karya Date :

Reference : SMG-SPM2-DS-40-0006-A4 Location : KP …............. to KP ….............

MATERIAL TO BE PROTECTED
Specification : Pipe API 5L X52 PSL2 Sch.XS Anode Type : SACP
Pipe Diameter : 609.6 mm Segment : Open Cut
Length (+/-) : m HDD

PRELIMINARY DATA (SMG-SPM2-CAL-30-0001-A4 & Prepackaged Anode Certificate PM-32-HP )


Soil Resistivity : 1500 Ωcm = 15 Ωm Anode Manufacturer : Gesit Nazelo Protection
Anode Potential : V (Pre-installed) Anode Material : Magnesium Alloy
Anode Net Weight : kg Bare Anode Dimension : W140xH146xL490 mm
Anode Gross Weight : kg Prepack Anode Dimension : ⌀210 x L720 mm
Backfill Composition : Hydrated Gypsum 75%; Bentonite 20%; Sodium Sulphate 5%

CHECKLIST ITEM

Visual appearance of anode OK NOT OK

Cable diameter at least 4 mm2 OK NOT OK

Anode-to-pipe (0.5 m) and anode-to-anode (1.5 m) spacing distance OK NOT OK

Exothermic welding in accordance with SMG-SPM2-PR-70-0048-A4 OK NOT OK

Thermo caps installed on pipe surface after thermite welding OK NOT OK

Copper sulfate (Cu/CuSO4) electrode reference cell installed OK NOT OK

Test point installed OK NOT OK

Visual appearance of all cable insulation & connection OK NOT OK

TEST POTENTIAL OVERALL RESULT

Pipe (Pre-installed) : V
ACCEPTABLE
System : V (-0.85 V or more negatif)
UNACCEPTABLE
(After installation of Cathodic Protection)

NOTE

Performed by, Inspected by, Inspected by, Verified by,


SUBCONTRACTOR PT. WIJAYA KARYA PT. PERTAMINA PERUSAHAAN INSPEKSI
Sign & Date Sign & Date Sign & Date Sign & Date

Name : Name : Name : Name :