Pega 367 with 04PC Control Layout Drawings ©Amada America, Inc.

Pega 367 with 04PC Control Layout Drawings

Amada America Inc.


7025 Firestone Blvd.
Buena Park CA. 90621
Phone: (714) 739 2111
Fax: (714) 739 4099
Email info@amada.com

Print Date 03/12/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 1 of 9
Pega 367 with 04PC Control Layout Drawings ©Amada America, Inc.

Warning
! Qualified personnel must complete all work.

! Do not apply power to the Pega 367 until an A.E.S.I. (Amada Engineering and
Service Incorporated) Engineer is present and has instructed you to do so.

! Not all information required for proper installation, of the Pega 367 is included with
this document. Specific details for proper installation are found in the document
Pega 367 with 04PC User Pre-installation Guide available at the Amada America
Internet web site at http://www.amada.com.

! Considerable effort has been made to ensure that this manual is free of
inaccuracies and omissions. However, as we are constantly improving our
product, some of the data contained herein may be out of date. Please check our
Internet site, http://www.amada.com, for the latest release of this document.

Print Date 03/12/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 2 of 9
Pega 367 with 04PC Control Layout Drawings ©Amada America, Inc.

Table Of Contents
Planning the Location of the Machine ..............................................................................................................................................4
Plan View - Pega 367.......................................................................................................................................................................5
Plan View - Pega 367 with V367hs Conveyor ..................................................................................................................................6
Plan View - Pega 367 with V367hs Conveyor and MP1530 Loader ................................................................................................7
End View - Pega 367 .......................................................................................................................................................................8
Elevation View - Pega 367 ...............................................................................................................................................................9

Print Date 03/12/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 3 of 9
Pega 367 with 04PC Control Layout Drawings ©Amada America, Inc.

Planning the Location of the Machine


The following diagrams provide the details for positioning your new machine.
! Not all information required for proper installation, of the Pega 367 is included with this document. Specific details for
proper installation are found in the document Pega 367 with 04PC User Pre-installation Guide available at the Amada
America World Wide Web site at http://www.amada.com.
! No obstacles are allowed in the worksheet travel area and the ceiling must be at least 40" above the Pega 367.
! All of the Recommended Safety / Maintenance areas should be used, but you must at least ensure that the doors of the
04PC control unit can be opened. Any reduction of the Recommended Safety / Maintenance areas may increase the
possibility of personnel injury and increase the time and cost of installation or maintenance.
! The Pega 367 and 04PC control must be protected from direct sunlight or other heat sources. Exposure to direct heating
sources such as infrared heaters have been shown to affect punch and die alignment.

Print Date 03/12/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 4 of 9
Pega 367 with 04PC Control Layout Drawings ©Amada America, Inc.

Plan View - Pega 367


Electrical Requirements
E1 Pega 367
230 / 460 / 3 / 60 ±10% 18 kVA
46 amps @ 230 / 3 / 60 VAC
23 amps @ 460 / 3 / 60 VAC 27.56"

Compressed Air Requirements


04PC
A1 Pega 367 80 psi @ 8.8 ft/³min.
Control
Operator Control Station

49.21"
E1

8"

32.45"

x.
ma
361.98" Recommended Safety / Maintenance Area 40" from all components

90"
. to "
min 3.15
50" 6
Pega 367
Y-axis zero position

Optional Material Support


60.00" working range

Tables Required
118.03"
199.20" Pega 367 Length
120" Maximum Travel Area 60" Material

Center Track 200


81.17"

Optional Material Support


Tables Required

A1

Centerline
Pega 367
12" 12" 12"
Scale

74.25" 76.69"
150.94" Pega 367 Width
288.00" Maximum Material Travel Area 144" Material
368.00" Recommended Safety / Maintenance Area 40" from all components

Print Date 03/12/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 5 of 9
Pega 367 with 04PC Control Layout Drawings ©Amada America, Inc.

Plan View - Pega 367 with V367hs Conveyor


Electrical Requirements
E1 Pega 367
230 / 460 / 3 / 60 ±10% 18 kVA
46 amps @ 230 / 3 / 60 VAC
23 amps @ 460 / 3 / 60 VAC 27.56"

E2 P367hs Conveyor
208 - 230 / 460 / 3 / 60 ±10% .8 kVA 04PC
2.1 amps @ 208 / 3/ 60 VAC Control
2.0 amps @ 230 / 3 / 60 VAC

49.21"
1.0 amps @ 460 / 3 / 60 VAC
Compressed Air Requirements
A1 Pega 367 80 psi @ 8.8 ft/³min. E1
Operator Control Station 8"

32.45"

ax.
m
90"
. to "
min 3.15
50" 6
420.41" Recommended Safety / Maintenance Area 40" from all components

Pega 367
Y-axis zero position

Optional Material Support


118.03"
60.00" working range

Tables Required
199.20" Pega 367 Length
120" Maximum Travel Area 60" Material

Center Track 200


81.17"

Optional Material Support


Tables Required

A1

P367hs
E2 12" 12" 12"
59.55"
Scale
Pega 367 Centerline

Access required
this area for
slug removal
44.85"

74.25" 76.69"
150.94" Pega 367 Width
288.00" Maximum Material Travel Area 144" Material
368.00" Recommended Safety / Maintenance Area 40" from all components

Print Date 03/12/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 6 of 9
Pega 367 with 04PC Control Layout Drawings ©Amada America, Inc.

Plan View - Pega 367 with V367hs Conveyor and MP1530 Loader
Electrical Requirements
E1 Pega 367
230 / 460 / 3 / 60 ±10% 18 kVA
46 amps @ 230 / 3 / 60 VAC
23 amps @ 460 / 3 / 60 VAC 27.56"

E2 P367hs Conveyor
208 - 230 / 460 / 3 / 60 ±10% .8 kVA 04PC
2.1 amps @ 208 / 3/ 60 VAC Control
2.0 amps @ 230 / 3 / 60 VAC

49.21"
1.0 amps @ 460 / 3 / 60 VAC
E3 MP1530 Loader
200 / 3 / 60 ±10%, 10 Kva
To operate at 230 / 460 VAC a step up E1 MP1530
transformer with the following service is Xformer E3
required 8"

32.45"

ax.
29 amps @ 200 / 3 / 60 VAC A2

m
26 amps @ 230 / 3 / 60 VAC

90"
. to "
min 3.15
13 amps @ 460 / 3 / 60 VAC

6
Compressed Air Requirements

50"
A1 Pega 367 80 psi @ 8.8 ft/³min.
420.41" Recommended Safety / Maintenance Area 40" from all components

A2 MP1530 Loader 75 psi @ 31.8 ft³/min.

Operator Control Station


Pega 367

139.00"
118.03"

Y-axis zero position

Optional Material Support


60.00" working range

223.80" MP1530 length


Tables Required
199.20" Pega 367 Length
120" Maximum Travel Area 60" Material

Center Track 200


81.17"

84.80"
Optional Material Support
Tables Required

A1

P367hs
MP1530
Forklift access required this area

E2
59.55"
Pega 367 Centerline

12" 12" 12"


Scale

Access required
this area for
slug removal
44.85"

74.25" 76.69" 162.66" MP1530 Width


77.69" to edge of MP1530
150.94" Pega 367 Width
288.00" Maximum Material Travel Area 144" Material
463.14" Recommended Safety / Maintenance Area 40" from all components

Print Date 03/12/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 7 of 9
Pega 367 with 04PC Control Layout Drawings ©Amada America, Inc.

End View - Pega 367

131.10"*

93.50"*

42.05"*
Material
Pass
Line

Floor Line 18.70" 12" 12" 12"


37.40" Scale
43.31"
76.69" 72.05"

*Dimension varies with installed options

Print Date 03/12/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 8 of 9
Pega 367 with 04PC Control Layout Drawings ©Amada America, Inc.

Elevation View - Pega 367


Track 200 Centerline
61.81"Throat Depth 60.00" Working Range

94.76"*

62.99"
43.31"*
Material
Pass Line

Floor Line 7.87" 27.56"


39.37" 36.61" 11.02"
39.37"
9.84" 6.50"
12" 12" 12"
112.59"
Scale
199.21"
*Dimension will change with installed options

Print Date 03/12/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 9 of 9