You are on page 1of 1

Middle Bridge - RCPT Summary

No. Location Casting Date Testing Date No. of Test Cubes Charged Passed (Columbs) Adjusted Charge Passed (Coloumbs) Average (Coloumbs) Company Chloride Ion Penetrability
182 -
1 P4 (1st cast) 21-10-19 17-12-19 3 94 - 169 BSEN Very Low
231 - Coloumbs passed Chloride Ion Penetrability
256 - >4000 High
2 P4 (2nd cast) 26-10-19 21-12-19 3 25 - 157 BSEN Very Low 2000 - 4000 Moderate
190 - 1000 - 2000 Low
192 174 100 - 1000 Very Low
3 P1 (1st cast) 08-11-19 03-01-20 3 224 203 205 USM Very Low <100 Negligible
262 238 *ASTM C1202
229 208
4 P1 (2nd cast) 14-11-19 09-01-20 3 217 197 209.67 USM Very Low
247 224
294 267
5 Abutment A 19-11-19 16-01-20 2 258.5 USM Very Low
276 250
231 210
6 P3 (1st cast) 23-11-19 21-01-20 3 185 168 180.67 USM Very Low
181 164
246 223
7 P3 (2nd cast) 28-11-19 24-01-20 3 330 299 244.67 USM Very Low
234 212
8 P3 Column (LHS) 07-12-19 03-02-20 1 323 293 293 USM Very Low
260 236
8 P2 (1st cast) 10-12-19 05-02-20 3 243 220 225.33 USM Very Low
242 220
250 227
9 P2 (2nd cast) 14-12-19 11-02-20 3 194 176 193 USM Very Low
194 176
312 283
10 P3 Column (RHS) 19-12-19 13-02-20 2 280 USM Very Low
305 277

12 P1 (E5) 09-09-20 04-11-20 3

13 P1 (M5) 10-09-20 05-11-20 3

14 P2 (E7) 3

15 P2 (M7) 3

16 P3 (M6) 3

17 P3 (E6) 3

18 P4 (M7) 3

19 P4 (E7) 3