Digital Radiography Technologies


About This Manual
The EConsole1 User Manual has prepared for the appropriate use of
digital radiography operating console software developed by DRTECH
Inc., This manual provides the instructions for the use of EConsole1.

The manual contains the following contents.

 Operation Environment, Installation and Method for EConsole1


 Functions and Instructions for EConsole1

Please contact us if there are any problems during the use of the
product.
WebSite http://www.drtech.co.kr
Customer Support Team Email drtech@drtech.co.kr
Tel +82 31 730 6805
Fax +82 31 730 6899

To Enhance The Quality Of Human Life!

DRT-MAN-055 (Rev. 06)


Copyright - EConsole1 Manual

Information contained in this manual is confidential and is the


property of DRTECH Inc., which is provided exclusively for authorized
licenses of DRTECH Inc.

The purpose of the manual is to assist the users to comprehensively


utilize the product of DRTECH Inc.

The information contained in this manual may not be altered or


distributed without prior written consent of DRTECH Inc., and may not
be disclosed to unauthorized personnel.

Information contained in the manual may be altered without prior


notice.

Copyright © 2013 DRTECH Corporation. All rights reserved.

DRT-MAN-055 (Rev. 06)


Table of Contents

1. INTRODUCTION ............................................................................................... 6

2. SYSTEM REQUIREMENTS ................................................................................. 7

2.1. SUPPORTED DIGITAL X-RAY DETECTOR ................................................................ 7


2.2. PC SPECIFICATION FOR THE SOFTWARE ............................................................... 7

3. INSTALLATION .................................................................................................. 8

3.1. INSTALLATION PREREQUISITES ............................................................................ 8


3.2. INSTALLATION .................................................................................................. 14
3.3. LANGUAGE & NUMBER OF DETECTOR SETTING .................................................. 15
3.4. LICENSE PROTECTION TYPE SELECTION ............................................................... 17
3.5. OPTION ........................................................................................................... 18
3.6. HOSPITAL & DEPARTMENT INFORMATION .......................................................... 19
3.7. INSTALLATION PATH CONFIGURATION ............................................................... 20
3.8. START MENU FOLDER CREATION ....................................................................... 22
3.9. ADDITIONAL TASK SETTING............................................................................... 23
3.10. INSTALLATION COMPONENT VERIFICATION .......................................................24
3.11. USB HAND SWITCH DRIVER INSTALLATION ..................................................... 25
3.12. INSTALLATION COMPLETE ............................................................................. 26
3.13. MAP FILE & ECALI1 CONFIGURATION .............................................................. 27
3.14. SETTINGS AFTER INSTALLATION ...................................................................... 30
3.15. UNINSTALL ECONSOLE1 .................................................................................. 31

4. ECONSOLE1 OVERVIEW .................................................................................. 32

4.1. PROGRAM START-UP ........................................................................................ 32


4.2. MAIN SCREEN OF THE PROGRAM ......................................................................34

5. LIST ..................................................................................................................39

DRT-MAN-055 (Rev. 06)


5.1. WORKLIST ...................................................................................................... 40
5.2. STUDYLIST .......................................................................................................54

6. EXAM ............................................................................................................... 74

6.1. TOOLBAR ......................................................................................................... 77


6.2. PROJECTION LIST & IMAGE PROCESSING TAB .................................................... 84
6.3. TRUVIEW ART ................................................................................................ 89

7. CONFIGURATION ........................................................................................... 90

7.1. DISPLAY ......................................................................................................... 92


7.2. SYSTEM ...........................................................................................................93
7.3. IMAGE ............................................................................................................ 99
7.4. STORAGE ....................................................................................................... 107
7.5. ACCOUNT ....................................................................................................... 112
7.6. BLOCK LIST ..................................................................................................... 113
7.7. DATASET ......................................................................................................... 114
7.8. NETWORK ...................................................................................................... 115
7.9. DETECTOR...................................................................................................... 124
7.10. RIS CODE .................................................................................................... 129
7.11. PROJECTION EDITOR ......................................................................................137
7.12. GENERATOR ................................................................................................. 143

APPENDIX A. GLOSSARY .................................................................................. 147

APPENDIX B. TERMINAL EMULATOR .............................................................. 150

APPENDIX C. UPDATE ...................................................................................... 166

APPENDIX D. PORTABLE FUNCTION.............................................................. 169

DRT-MAN-055 (Rev. 06)


1. Introduction
EConsole1 is digital radiography operating console software
specialized for the FLAATZ and EVS series digital X-ray detector
developed by DRTECH Inc.
EConsole1 provides an integrated solution for X-ray projection. It
integrates with the X-ray generator and the digital detector.
Furthermore, EConsole1 acquires and processes images. In addition, it
complies with DICOM standards and is able to transmit and receive
data with the PACS system, and print images through the DICOM
printer.

Figure 1. X-Ray Projection Solution Utilizing EConsole1 (Wired Detector)

Figure 2. X-Ray Projection Solution Utilizing EConsole1 (Wireless Detector)

DRT-MAN-055 (Rev. 06) 6


2. System Requirements

2.1. Supported Digital X-ray Detector

EConsole1 supports the following Digital X-ray Detectors developed by


DRTECH.
 FLAATZ 330N LAN
 FLAATZ 500 LAN
 FLAATZ 560 LAN
 FLAATZ 600 Wireless LAN
 FLAATZ 750E LAN
 FLAATZ 760 LAN
 EVS 4343 LAN

2.2. PC Specification for the Software

Table 1. PC Specifications

Items Recommended
CPU Intel i5-3470
RAM 8 GB
HDD 500 GB
NVIDIA GeForce
VGA
GT630 1GB
ODD DVD Recorder
Windows 7 Pro
OS
32 / 64bit
Display Size 23 inch
Display Resolution 1920 x 1080
* Optimal performance is not guaranteed for PCs that do not comply with
the recommended specifications.

DRT-MAN-055 (Rev. 06) 7


3. Installation

3.1. Installation Prerequisites

3.1.1. Windows 7

Windows 7 users must set the User Account Control (herein after ‘UAC’)
permission and disable the firewall.

3.1.1.1. UAC Setting


① Click the start icon .
② Click ‘Control Panel’.
③ Select ‘User Accounts’.
④ In the User Accounts window, click ‘User Accounts’.
⑤ In the User Accounts task window, click ‘Change User Account
Control Setting’.
⑥ Adjust the slider to the ‘Never notify,’ and then click ‘OK’.

3.1.1.2. Disabling the Firewall


① Click the Start icon .
② Click ‘Control Panel’.
③ Click ‘Security’.
④ Click ‘Windows Firewall’.
⑤ Click ‘Turns Windows Firewall on or off’ on the left.
⑥ Click ‘Off (not recommended),‘ and then click ‘OK’.
3.1.1.3. Set Power Options
① Click 'Setting' on the right hand menu.
② Click 'Control Panel'.
③ Click 'Power Options'
④ Select 'High performance' or 'Energy Manager High

DRT-MAN-055 (Rev. 06) 8


Performance Mode'

3.1.1.4. Set Power Options


① Click 'Setting' on the right hand menu.
② Click 'Control Panel'.
③ Click 'Power Options'
④ Select 'Choose when to turn off the display' menu on the left
side.
⑤ Set 'Put the computer to sleep' to 'Never' and click Save
changes.
3.1.1.5. Disable Windows update setting
① Click 'Setting' on the right hand menu.
② Click 'Control Panel'.
③ Click 'Windows Update'
④ Select 'Change settings' menu on the left side.
⑤ Set 'Important updates' to 'Never check for updates(not
recommended'

DRT-MAN-055 (Rev. 06) 9


⑥ Uncheck 'Give me recommended updates the same way I
receive important updates'
⑦ Uncheck ''Give me updates for other Microsoft products when
I update Windows'

DRT-MAN-055 (Rev. 06) 10


3.1.2. Windows 8

Windows 8 users must set the User Account Control (herein after ‘UAC’)
permission, disable the firewall and run the program as the system
administrator.
3.1.2.1. UAC Setting
① Click ‘Setting’ on the right hand menu.
② Click ‘Control Panel’.
③ Select ‘User Accounts’.
④ In the User Accounts window, click ‘User Accounts’.
⑤ In the User Accounts task window, click ‘Change User Account
Control Setting’.
⑥ Adjust the slider to the ‘Never notify,’ and then click ‘OK’.
3.1.2.2. Disabling the Firewall
① Click ‘Setting’ on the right hand menu.
② Click ‘Control Panel’.
③ Click ‘Security’.
④ Click ‘Windows Firewall’.
⑤ Click ‘Turns Windows Firewall on or off’ on the left.
⑥ Click ‘Off (not recommended),‘ and then click ‘OK’.
3.1.2.3. Run as Administrator
 Windows 8 users must run the Installation File and Program as
the Administrator.
 Install the program by right clicking (press and hold, if touch
screen) and selecting ‘Run as Administrator’.
 After completing the installation, set the icon, so that it always
runs as administrator.
① Right click (press and hold, if touch screen) the shortcut
icon.
② Click ‘Properties’.
③ Click the ‘Advanced’ icon in the ‘Shortcut’ tab‘.
④ Check the ‘Run as administrator’ box, click on ‘OK’.

DRT-MAN-055 (Rev. 06) 11


3.1.2.4. Do not change Compatibility mode
 EConsole1.exe's right clicking(press and hold, if touch screen)
and select 'Compatibility' tab.
 Make sure that EConsole1.exe's compatibility mode is not
checked.
3.1.2.5. Disabling the Windows update
① Click ‘Setting’ on the right hand menu.
② Click ‘Control Panel’.
③ Select ‘Windows Update’.
④ In the Windows Update window, click ‘Change settings’.
⑤ In the Change setting window, Change to ‘Never check for
updates(not recommended)’.
⑥ Uncheck 'Give me recommended updates the same way I
receive important updates.

Figure 3. Windows update setting window

3.1.2.6. Power options setting(Only use Laptop)


 Click 'Setting' on the right hand menu.
 Click 'Control Panel'.
 Click 'Power Options'

DRT-MAN-055 (Rev. 06) 12


Figure 4. Windows power options setting window

 Select 'High performance' or 'Energy Manager High


Performance Mode'
Power options setting
 Click 'Setting' on the right hand menu.
 Click 'Control Panel'.
 Click 'Power Options'
 Select 'Choose when to turn off the display' menu on the left
side.
 Set 'Put the computer to sleep' to 'Never' and click Save
changes.
3.1.2.7. Disable SmartScreen
① Click 'Setting' on the right hand menu.
② Click 'Action Center'
③ Click 'Change Windows SmartScreen setting'
④ Set 'Don't do anything(turn off Windows SmartScreen)

DRT-MAN-055 (Rev. 06) 13


⑤ Click 'OK'

3.2. Installation

Run the provided setup file.

 A minimum of 10GB of available HDD space is required for the


proper installation of EConsole1!
 0.5.6 is the version of the product, and may change.
 Windows 8 users must run the file as ‘administrator’.
 Right-click the file, select ‘Run as administrator’ in the menu.

If the setup file is run, you will be presented with the following screen
as in, [Figure 5].
Click ‘Next’ to start the installation.

Figure 5. Setup Wizard Window

DRT-MAN-055 (Rev. 06) 14


3.3. Language & Number of Detector

Setting

Select a language to be used in the Econsole1 vet program.


Click ‘Next’ after selection.

Figure 6. Language & Number of Detector Setting

① Language Setting

Please select the appropriate language.


 It may be set after the program installation.
 It can be set through Configuration - System - Language.
 Please refer to 7.2.1. Language (p. 94) for setting after
installation.

DRT-MAN-055 (Rev. 06) 15


② Number of Detector Setting

Please select whether to use 1 or 2 detectors.

 Be Advised!
 For Dual Mode using 2 detectors, there are restrictions to
models which are able to use the detectors simultaneously.

 Dual Mode (2 detector use) supported detectors


 FLAATZ 500 LAN
 FLAATZ 560 LAN
 FLAATZ 600 Wireless LAN
 FLAATZ 750E LAN
 FLAATZ 760 LAN
 EVS 4343 LAN
 EVS 3643 LAN

 It may be set after program installation.


 It can be set through Configuration - Detector.
 Please refer to 7.9 Detector (p. 124) for setting after
installation.

DRT-MAN-055 (Rev. 06) 16


3.4. License Protection Type Selection

Figure 7. License Protection Type Selection

Selects license protection type you purchased.

 Hardware License Protection (Dongle Key)


 Utilizes a license key embedded within a special USB device.
This device must be attached to the PC in order for
Econsole1 to operate.
 Software License Protection
 The license is provided as a serial number to be entered
during installation.

DRT-MAN-055 (Rev. 06) 17


3.5. Option

Select the model and input the serial number of the X-ray Detector to
be used with the EConsole1. Click ‘Next’ after selection.

 It may be set after program installation.


 It can be configured through Configuration - Detector.
Please refer to 7.9 Detector (p. 124).

Figure 8. Option: Detector Setting

① X-ray Detector Model Selection

 Set the X-ray Detector, which will be used with FConolse1.


 Select the appropriate model.

② Enter the X-ray Detector Serial Number

 Enter the serial number of detector.

DRT-MAN-055 (Rev. 06) 18


3.6. Hospital & Department Information

Enter the Hospital name and department name.

Figure 9. Hospital & Department Information

DRT-MAN-055 (Rev. 06) 19


3.7. Installation Path Configuration

3.7.1. Select EConsole1 Install Folder

 You may designate the folder in which to install the program


through the ‘Browse’ icon.
 Please verify that there is sufficient space on the HDD where
the program will be installed!
 The program requires a minimum of 2GB of available space.
 After specifying the location, click ‘Next’.

Figure 10. EConsole1 Install Folder Selection

DRT-MAN-055 (Rev. 06) 20


3.7.2. Select Image Save Folder

 You may designate the folder in which to install the program


through the ‘Browse’ icon.
 After specifying the location, click ‘Next’.
 If user want to change it is possible only 'drive:\Images' folder.

Figure 11. Image Save Folder Selection

DRT-MAN-055 (Rev. 06) 21


3.8. Start Menu Folder Creation

Specify a start menu folder name for the program icons, or select not
to create a start menu entry.
Click ‘Next’.

Figure 12. Start Menu Folder Selection

DRT-MAN-055 (Rev. 06) 22


3.9. Additional Task Setting

Select whether to create shortcut icons in the desktop and Quick


Launch Bar.
Click ‘Next’.

Figure 13. Additional Task Setting

DRT-MAN-055 (Rev. 06) 23


3.10. Installation Component Verification

Displays the summary of configured components to be installed.


Start the installation by clicking the ‘Install’ icon, and please wait while
installing.

Figure 14. Installation Component Verification

DRT-MAN-055 (Rev. 06) 24


3.11. USB Hand Switch Driver Installation
Install USB Hand Switch Driver for F600, EVS4343 and EVS3643.

Figure 15. USB Hand Switch Driver Installation

DRT-MAN-055 (Rev. 06) 25


3.12. Installation Complete
Once the installation has completed, it is strongly recommended that
you allow the PC to be restarted. Make sure “Yes, restart the
computer now” is selected and click next.

Figure 16. Installation Complete

DRT-MAN-055 (Rev. 06) 26


3.13. Map File & ECali1 Configuration
There are three files that are provided with your detector panel that
must be copied to the hard drive in order for the software to operate.
These files are unique to your specific panel.

3.13.1. Map File


DRTECH provide the MAP CD like below.

그림 17. MAP file CD

The files can be found on the CD in the folder named MAP.


These files consist of the following:

 Pixel MAP file: [Detector serial number].MAP


 Gain MAP file: [Detector serial number].GMP
 Panel MAP file: [Detector serial number].PMP

Please copy these files to [EConsole1 installation folder]\Map folder.


Even you use 2 or 3 detector do not make special folder and copy it
to [EConsole1 installation folder]\Map folder.

EConsole1 search the Map files using set detector's serial number.

DRT-MAN-055 (Rev. 06) 27


So, Map file name and the registered serial number must be matched.

그림 18. Serial number & map files

DRT-MAN-055 (Rev. 06) 28


3.13.2. ECali1 Configuration
You must setup various settings of detector using ECali1.

For setting up using ECali1, please refer to the ECali1 manual.

Figure 19. ECali1

DRT-MAN-055 (Rev. 06) 29


3.14. Settings after Installation

Windows 8 users must set EConsole1 so that it runs as administrator.

 Right click (press and hold) the EConsole1 shortcut icon in the
desktop.
 Click ‘Properties’.
 Select ‘Advanced’ in the ‘Shortcut’ tab.
 Check the ‘Run as administrator’ box, then click ‘OK’.

DRT-MAN-055 (Rev. 06) 30


3.15. Uninstall EConsole1

 Click ‘Uninstall EConsole1’ in Windows start menu – All


Programs - EConsole1.

DRT-MAN-055 (Rev. 06) 31


4. EConsole1 Overview

4.1. Program Start-up

In order to run the program, you can double click the EConsole1 icon
in the desktop or select ‘EConsole1’ by Windows Menu – All Programs
– EConsole1.

Figure 20. EConsole1 Shortcut Icon

If the program is properly initiated, a log-in screen as the one you see
in [Figure 21] will appear.

Figure 21. Log-in Screen

Enter the ID and Password, then click the Login icon.

DRT-MAN-055 (Rev. 06) 32


If you enter an invalid ID or Password, you will be presented with a
screen as in [Figure 22] and will not be able to log in.

Figure 22. Log-in Error

DRT-MAN-055 (Rev. 06) 33


4.2. Main Screen of the Program

You will be presented with EConsole1 main screen as in [Figure 23]


with a successful log-in.

Figure 23. Main Screen of EConsole1

DRT-MAN-055 (Rev. 06) 34


4.2.1. Function Tabs

It pertains to area ⓐ in [Figure 23], and there are two tab icons on
the upper left corner.

Figure 24. Tab Icons of EConsole1

These tabs are used to carry out various functions of EConsole1. The
functions of each tab are as follows.

Manages the Worklist and Studylist.


Worklist is the list of patients.
Studylist is the list of examined studies.
Refer to 5. List (p. 39) for more details
Performs X-ray projection of selected a patient in
the Worklist, or reviews selected examined study
in the Studylist. Refer to 6. Exam (p. 74) for more
details.

DRT-MAN-055 (Rev. 06) 35


4.2.2. Status Information Display

It pertains to the lower area ⓑ in [Figure 23], and displays various


status information as in [Figure 25].

Figure 25. Status Information Bar

① Hardware & Connection Status Display

Displays the status of the hardware and the connection status between
equipment requiring connections

[FLAATZ-600]
Displays the acquisition mode in detector.
There are AED and Switch box mode.
[EVS-4343, EVS-3643]
Displays the acquisition mode in detector.
There are AED, Switch box, Sync mode.
If the user want to change the mode click the
icon and the default mode could change using
ECali1.(ECali1 - Configuration - Detector X -
Exposure mode)
Mode change sequence.
∙ USB Switch box : USB Switch box <-> AED
∙ Sync Trigger : Sync Trigger <-> AED
∙ AED : AED only
Displays the connection status and the available
space of the currently connected HDD.
The displayed number is the ratio of the
remaining HDD volume.

Displays the connection status(On/Off) with the X-


ray detector.

DRT-MAN-055 (Rev. 06) 36


[EVS4343, EVS3643]
Displays the temperature.
Displays the connection status with Storage
Server.
When you click this icon, the pop-up window will
be show. You can change the PACS or do test in
it.
The UI is almost same as Configuration's PACS
menu.
Refer to 7.8.3 PACS (p. 119)
Displays the connection status with the DICOM
Printer.
Displays the connection status with the Modality
Worklist server.
[FLAATZ-600, EVS-4343, EVS3643]
Displays the battery condition of the wirelessly
connected detector.
The displayed number indicates the ratio of
remaining battery life.
[EVS-4343, EVS-3643]
Battery is in wireless charging.
[FLAATZ-600, EVS4343, EVS-3643]
Displays the signal strength of the wirelessly
connected detector.

② Current Time & Log-in Information Display

 Displays the current date, time and user.


 The program can be terminated by clicking the Logout icon.

DRT-MAN-055 (Rev. 06) 37


③ Configuration Icon

 Opens the Configuration screen for various settings.


 Refer to 7. Configuration (p. 90) for more details.

DRT-MAN-055 (Rev. 06) 38


5. List
The List tab displays the list of patients and studies as described below.

 Worklist
 Displays the list of patients scheduled for examination.
 Allows users to add/edit/delete patients on the list.
 Allows users to proceed to exam for the selected patient.
 When you run the Econsole1 Vet for the first time you will
be asked to specify the list length. It will be saved
automatically.
Please refer to 5.1 Worklist (p.40) for more details.

 Studylist
 Displays the examined studies.
 Allows users to edit/delete the examined studies on the list.
Note, editing and deletion of images on the list will not
affect to the PACS server.
 Allows users to transmit examined images to the PACS
server.
 Please refer to 5.2 Studylist (p. 54) for more details.

 Please note!
 The information on the Worklist and Studylist are stored on
the Local Storage (HDD) by default.
 Every time Econsole1 is launched, a new Worklist is
retrieved from the Worklist server and stored on the Local
Storage.
 Contents on the list which are edited and deleted in
Econsole1 Vet only affects the Local Storage by default.
However, edited records may be transmitted to the PACS
server using the Send command.

DRT-MAN-055 (Rev. 06) 39


5.1. Worklist

Displays the list of patients.


The list is displayed when the icon, on the upper
portion of the List tab, is clicked.

5.1.1. Main Screen of the Worklist

The main screen of the Worklist is as seen in [Figure 26].

Figure 26. Worklist Screen

DRT-MAN-055 (Rev. 06) 40


① List of Patients

 The types of information are as noted in [Table 2].


 The displayed information and its order may be set in
Configuration.
 The display order may be changed by clicking and dragging
the name of the information type(ID, Name and etc.).
 If you run the EConsole1 first, please set the column size at
your convenience it will save automatically.

Table 2. Information Type of the Worklist

Type Description
Accession Number.
Acc. No.
X-ray study registration number
ID Patient ID
Name Patient name
Date/Time Expected time of study
Study Desc. Study Description
D.O.B. Date of Birth
Sex Sex of the patient
Order Date Time of order

 Patient selection in the Worklist.


 Patient can be selected by left-clicking the mouse.
 The selected patient is displayed in blue .
 Patient can be edited and deleted after selection.
 Projection can be performed in the Exam tab as a selected
patient is double-clicked.
 It is equivalent to clicking the ‘Exam’ icon after selecting a
specific patient.
 Please refer to 6. Exam (p. 74) for more details.

DRT-MAN-055 (Rev. 06) 41


② Search Bar & Refresh Icon

 Search Bar

 Searches the values of Patient ID, Name, and Access


Number within the Worklist.

 If the is clicked after entering the value to be


searched, the list will only display relevant works.

 If the icon is clicked without entering a specific value,


an advanced search window will appear.

 Advanced Search Window

Figure 27. Advanced Search Window

DRT-MAN-055 (Rev. 06) 42


 Performs searches utilizing multiple conditions
simultaneously.
 Only displays works satisfying all entered details.

 Refresh icon
 Retrieves recently registered patients from the PACS server.
③ Add/Edit/Delete Icon

Table 3. Add/Edit/Delete Icon

Icon Description

Adds a new patient.


Add Window is opened when the pertinent icon is clicked.
Please refer to 5.1.2 Add Window (p. 45) for more details.
Add
Edits the selected patient information on the Worklist.
Only allows editing of patient information added by EConsole1.
Edit Window is opened when the patient is selected and the edit
icon is clicked.
Edit
Please refer to 5.1.4 Edit Window (p. 51) for more details.

Deletes the selected patient.


Only deletes the patients added by EConsole1.
Delete

Import the excel file to worklist


Please refer to for more details.
Excel Please refer to for more details.
import

Save patient list to detector.


This function works only FLAATZ-600, EVS-3643 detector.
Please refer to for more details.
Portable

DRT-MAN-055 (Rev. 06) 43


④ Exam Icon

 Switches to the Exam tab to exam of the selected patient.


 Please refer to 6. Exam (p. 74) for more details.

DRT-MAN-055 (Rev. 06) 44


5.1.2. Add Window

Add Window appears when the icon is clicked [Figure 28].

Figure 28. Add Window

DRT-MAN-055 (Rev. 06) 45


① Patient Information

Study, patient, radiographer information is entered.


Details for each category are as described in [Table 4].

Table 4. Patient Information (Add Window)

Category Description
ID Patient ID
Accession Number Registered identification number
Name Patient Name
Operator Radiographer Name
Sex Sex of the patient
Birth Date Date of birth of the patient
Age Age of the patient

② Emergency Icon

 If this icon is clicked, a default value is set as the ID and


Accession Number and switches over to the Exam tab.

③ Projection Information

 Displays information of projection.


 In no information is provided initially, the projection
information can be set by clicking ④ Edit icon.

④ Edit Icon

 Opens the projection setting window where projection


information may be entered.
 Please refer to 5.1.3. Edit Projection (p. 49) for more details.

DRT-MAN-055 (Rev. 06) 46


⑤ OK Icon

 Saves the patient with the entered information and closes the
window.

⑥ Exam Icon

 Saves the patient with the entered information and directly


switches to the Exam tab to exam.
 Please refer to 6. Exam (p. 74) for more details.

⑦ Cancel Icon

 Cancels the work addition and closes the window.

* Note

If multiple projections are registered for a single patient, each projection


receives a different Accession Number [Figure 29].

Figure 29. Multiple Projections Registration in a Single Event

If the OK icon is clicked, each projection registered in the Worklist as 2

DRT-MAN-055 (Rev. 06) 47


different studies. [Figure 30]

Figure 30. Two studies for one patient

In order to register projections as a single study, the Accession Numbers for


each projection must be equally modified prior to clicking the ‘OK’ icon.
[Figure 31]

Figure 31. Enter the Same Accession Number to Register as a Single Study

DRT-MAN-055 (Rev. 06) 48


5.1.3. Edit Projection Window

It is the window which appears on the Add Window when the Edit
icon is clicked.

Figure 32. Edit Projection Window

① Anatomy Information

 Select the anatomical region to be examined.


 Projection and Position are determined subsequent to the
selected anatomical region.
 Receptor Type will be changed by clicking the icon.

Stand Table Wireless1 Wireless2 Wireless3

DRT-MAN-055 (Rev. 06) 49


② Projection & Position List

 Specific selection of regions selected in Anatomy.

③ Add Icon

 This icon registers the currently set Projection, Position,


Receptor Type information.
 The currently set Projection, Position and Receptor Type
information is also registered when the selected Position is
double clicked.

④ Registered Projection Information

 Displays the list of registered Projection, Position and Receptor


Type.
 The Receptor Type can be altered by double clicking the
Position in Dual Mode.

⑤ Projection Information Sequence Edit Icon

 Changes the projection order.

Up Down

⑥ Delete Icon

 Deletes the selected item.

⑦ OK Icon

 Saves and closes the window.

DRT-MAN-055 (Rev. 06) 50


⑧ Cancel Icon

 Cancels and closes the window.

5.1.4. Edit Window

The Edit Window opens when a study is selected from the


Worklist and the Edit icon is clicked.
(Caution) Edit Window is not able to be modified on the study
information, retrieved from the PACS server.

Figure 33. Edit Window

DRT-MAN-055 (Rev. 06) 51


① Study Information

 Edits the information of the radiographer and the patient.


 Information are as described in [Table 5].

Table 5. Study Information (Edit Window)

Category Detail
ID Patient ID
Name Patient Name
Accession Number Registered identification number
Operator Radiographer Name
Study Description Study Description
Sex Sex of the Patient
Birth Date Date of Birth of the Patient
Age Age of the Patient
Schedule date & time Scheduled date and time of imaging

② OK Icon

 Saves and closes the window.

③ Cancel Icon

 Cancels and closes the window.

5.1.5. Edit Window

① Make a patient list

✓ Use the template found at


'installed path\ Config\Worklist_sample.xlsx' to make a patient list.

DRT-MAN-055 (Rev. 06) 52


② Limitation

 You can select among the 'M', 'F', 'U' in patient Sex.
 Birth Date and Study Date's format is 'MM/DD/YYYY'.
It is not support other format.
 Birth Time and Study Time's format is 'HH:MM:SS'.
It is not support other format.

③ Excel import

 Click the excel Import and load the file.

DRT-MAN-055 (Rev. 06) 53


5.2. Studylist

Displays the examined study list.

The list is visible if the icon at the top of the List tab is
clicked.

5.2.1. Main Screen of the Studylist

The main screen of the Studylist is as seen in [Figure 34].

Figure 34. Main Screen of the Studylist

DRT-MAN-055 (Rev. 06) 54


① List of the Examined Patients

 Displays the list of various information of the examined patients.


 One row represents one patient information and one ID
may have multiple studies.
 The column of the list may be changed by dragging the
name of the category (ID, Name and etc.).
 You can change the list's height using Ctrl key + Mouse wheel
or using Ctrl key + arrow key
 Types of information are as noted in [Table 6].

Table 6. Information Types of Patient

Category Description
Name Patient name
ID Patient ID
Sex Sex of the patient
D.O.B. Date of Birth
Date/Time Date / time for recent examined study

 Patient Selection
 Patient can be selected by clicking the left button of the
mouse.
 Selected patient is displayed in blue.
From the ‘① Examined Patient List’ and ‘② Examined Study
List per Patient’.
 Selected patient may be edited or deleted.

② Examined Study List per Patient

 Displays detailed study information of the selected patient on


the ‘① List of the Examined Patients’.
 Types of information are as noted in [Table 7].

DRT-MAN-055 (Rev. 06) 55


Table 7. Information Types of Examined Study List

Items Description
Accession Number
Acc. No.
Registered identification number
Study ID RIS code
Study Desc. Study Description
Status [Number of images] / [Number of projections]
Date/Time Date / time for examined study.

③ Thumbnail

 Displays the images from the selected patient.


 A check mark is added to thumbnail of the selected images for
the opening or transmission.
 The thumbnail can be selected by double clicking.
 Images transmitted to the PACS server have a green outline.
 1/1 : Series number / image number

④ Search Bar & Refresh Icon

 Search Bar
 Searches the values of Patient ID, Name, and Access
Number within the Studylist.

 If the is clicked after entering the value to be


searched, the list will only display relevant works.

 Refresh Icon
 Renews the list to the latest state.

DRT-MAN-055 (Rev. 06) 56


⑤ Icons

Table 8. Studylist Icons

Icon Description
Detailed overview of a single selected image from the list of
thumbnails.
Open Study Please refer to 6. Exam (p. 74) for more details.

Repeat exam for the selected study in the Exam tab.

Repeat Exam Please refer to 6. Exam (p. 74) for more details.

Performs merging of two studies or patients.


Please refer to 5.2.2 Merge Window (p. 58) for more
Merge details.
Stores images on a USB, CD, or DVD, and print through the
DICOM Printer.

Export Please refer to 5.2.3 Export Window (p. 60) for more
details.
Edits the selected patient or study information in the
Studylist.

Edit Edit Window appears if the Edit Icon is clicked.


Please refer to 5.2.4 Edit Window (p. 65) for more details.

Deletes the selected item.


Delete

Save the patient list to excel.


Excel export

It makes selected series's report.

Report Please refer to for more details.

⑥ Send Icon

 Transmits the selected images to the PACS server.

DRT-MAN-055 (Rev. 06) 57


5.2.2. Merge Window

 Merges the images and studies.


 Allows editing when the image and patient information do not
correspond with each other.

Figure 35. Merge Window

① & ② Merge Subject Imaging Information

 Study lists appear on each side.


 Required items can be easily searched using the search tool.
 Identical items selected items in ① are located in ② if the
SameList is checked.

DRT-MAN-055 (Rev. 06) 58


③ Merge Icon

 Transmits the selected items.


 Everything is saved while being transmitted.

④ Close Icon

 Closes the Merge window.

DRT-MAN-055 (Rev. 06) 59


5.2.3. Export Window

Saves the images of the selected study from the Studylist to a USB, CD
or DVD, and prints it through the DICOM Printer.

5.2.3.1. Drive

Figure 36. Export USB Screen

 Stores the images in the local drive.


 Only files in BMP, JPG, PNG and TIF format may be exported.
 If the local drive is selected, the current list of stored files are
displayed.
 Export File Format
 Selects Format for storage.
 Image is stored to the USB once the OK icon is clicked.
 File name is automatically designated and it will be stored It
will be stored at 'driver\ID_Name\' folder. .

DRT-MAN-055 (Rev. 06) 60


5.2.3.2. Print

Figure 37. Export - Print Screen

 Prints through the DICOM Printer.


 The DICOM Printer must be connected.

① Print Setting

 Printer Selection
 Selects a DICOM Printer.
 You can register using 'Config' - 'Network' - 'Printer' menu.
 Film Orientation
 Selects a film orientation between portrait/landscape.
 Film Size
 Selects the size of the film.
 Layout
 Sets the print layout.

DRT-MAN-055 (Rev. 06) 61


 The ‘Divide’ icon must be clicked in order to apply any
changes made in Layout.
 Zoom
 Performs zoom in/out of image.
② Preview

 Thumbnail Screen
 The image to be printed appears in the thumbnail list on
the right.
 Preview Screen
 If an image is selected in the thumbnail, a large image
appears in the center preview screen.
 Merge Icon
 Merges the divided screen which has been separated by
‘Divide’.
 Only adjacent screens of the same sizes can be merged
 The merged shape must be a square.
 Divide Icon
 Divides the screen by the value set in ‘Layout’.
 Rotation Icon
 Rotates the screen 90 degrees clock-wise.
 Flip Icon
 Reverses the up and down sides.
 Print Icon
 Run a paper print

③ DICOM Print button

 Performs printing.

DRT-MAN-055 (Rev. 06) 62


5.2.3.3. CD / DVD

Figure 38. Export - CD / DVD

 Stores the images on a CD or DVD.


 Only DICOM files can be Exported.
 A CD/DVD Recorder device is required.

① CD / DVD Media Configuration

 Selects the target media to be exported.


 CD, DVD are available.
 Volume Label
 Configures the name of the target media.
 Total Space
 Displays the total available space of the target media.
 Insert
 Closes the CD / DVD Recorder device.

DRT-MAN-055 (Rev. 06) 63


 Eject
 Opens the CD / DVD Recorder device.

② Export File List

 Displays the list of files to be Exported.

③ Export Process

 Estimated Time
 Presents the expected time needed for Export.
 Time Left
 Displays the time left of the estimated time.

④ Task Icons

 Burn
 Performs the Export task.
 Cancel
 Cancels the Export task.

DRT-MAN-055 (Rev. 06) 64


5.2.4. Edit Window

5.2.4.1. Edit Patient Information

Figure 39. Edit Window on Studylist (Patient Information)

 Only patient information (within the red outline) can be edited


when the Edit icon is clicked in the patient list of the Studylist
(upper list).
 OK Icon
 Saves and closes the window.
 Cancel Icon
 Cancels and closes the window.

DRT-MAN-055 (Rev. 06) 65


5.2.4.2. Edit Study Information

Figure 40. Edit Window on Studylist (Study Information)

 Only study information (within the red outline) can be edited


when the Edit icon is clicked in the projection list (lower list) of
the Studylist.
 OK Icon
 Saves and closes the window.
 Cancel Icon
 Cancels and closes the window.

DRT-MAN-055 (Rev. 06) 66


5.2.5. Report

5.2.5.1. Report

Figure 41. Create Report

 Create report using Report button in the StudyList.


① Patient information

 Check or change the Selected series's patient information.


② Attached image

 User can attach up to 4 images using the 'Image load' button.

DRT-MAN-055 (Rev. 06) 67


③ Write opinion

 User can write opinion.


④ Print / Save / Setting

 User can print the report.


 Save a report to PDF file.
 Save a report.
 Set the report Format.

DRT-MAN-055 (Rev. 06) 68


5.2.5.2. Image load

Figure 42. Create Report

 Layout button
 Select 1X1, 1X2, 2X2 layout.
 Image load button
 Select image
 OK button
 Attach the selected image to report
 Cancel button
 Cancel to attach images

DRT-MAN-055 (Rev. 06) 69


5.2.5.3. Select the image

Figure 43. Select the image

 You can select the image when you click "Image load" button.
 Search button
 Search the patient using input information.
 Patient/Series/Image list
 Select the image.
 OK button
 Load the selected image.
 Cancel button
 Cancel to load the image.

DRT-MAN-055 (Rev. 06) 70


5.2.5.4. Input the opinion

Figure 44. Select the image

 Input the selected series opinion.

DRT-MAN-055 (Rev. 06) 71


5.2.5.5. Set report form

Figure 45. Set report form

 User can set the report form using 'setting' menu.


 Address/ Extra Info
 Input the Hospital address or further information.
 Session
 Input the Session.
 Default values are "RECOMMENDATION", "FINDING", and
"CONCLUSION".
 Visible setting
 Select the printing report's contents.
 All selection is default value.
 Save as default button.
 Save current value as default.
 OK button
 Use selected form.
 Cancel button
 Cancel the selected form.

DRT-MAN-055 (Rev. 06) 72


5.2.5.6. Print

Figure 46. Print

 User can print the report using print button.

DRT-MAN-055 (Rev. 06) 73


6. Exam
 The Exam tab processes exam and edit images.

Figure 47. Main Screen of Exam Tab

① Patient Information

 Displays ID, patient name, study description.

② Detector Status Display

 Displays the status of the detector to be used in exam.


 Blue: Ready state

DRT-MAN-055 (Rev. 06) 74


 Orange: Busy state
③ Image Display Screen

 Area - display images.

④ Toolbar

 Collection of edit image icons


 The width of the column may be changed.
 Please refer to 6.1 Toolbar (p. 77) for detailed information.

⑤ Projection List & Image Processing Tab

 May view the list for images, or set the post-processing


parameter which will be applied to the images.
 Please refer to 6.2 Projection List & Image Processing Tab (p.
84) for detailed information.

⑥ Generator Condition Setting

 Only available with integration with X-ray generator.


 Tube Voltage (kVp), Tube Current (mA), Tube Current Amount
(mAs) setting.
 If the tube current amount icon, mAs, is clicked, the unit
may be changed to exposure time (seconds).
 Patient Size
 Selects the volume of the patient‘s body.
 Sets value of the tube current, tube voltage and tube
current amount, are renewed subsequent to the patient’s
volume.
 AEC
 Sets the AEC to be used.
 Density

DRT-MAN-055 (Rev. 06) 75


 Configures the imaging density.
 Focus
 Configures the Focal Size.
 Grid
 Configures the applied Grid.

⑦ Save / Indicator / Send Icons

 Save Icon
 Stores the images on the Local Storage.
 Send Icon
 Transmits the images to the PACS server.
 Transmits all images performed to this icon with a Long-
click to the PACS server.
 Indicator Icon

Standby Ready Exposure

 Standby: Default status. May begin exam.


 Ready: Ready for the detector to get image.
 Exposure: Emits x-ray to the detector.

DRT-MAN-055 (Rev. 06) 76


6.1. Toolbar

Collection of icons required for image analysis and editing.

6.1.1. Toolbar Overview

① Toolbar Width Adjustment Icon

 The width can be changed by clicking this icon.


 The width may be set from 1 to 4.

② Tools List

 Displays the currently configured list of icons.


 The icons can be edited in the Edit Toolbar
window.

③ Edit Icon

 Opens the Edit Toolbar window for editing the


icons.
 Please refer to 6.1.2 Edit Toolbar (p. 78) for
detailed information.

DRT-MAN-055 (Rev. 06) 77


6.1.2. Edit Toolbar

Figure 48. Edit Toolbar Window

① Applied Icons Box

 It is the currently applied icons in the Exam tab.


 Icons in this box can be deleted by drag & drop of the icon
into ‘② Tools Collection’.
 Icons can be added into this box by dragging icons in ‘② Tools
Collection’ and dropping it into the empty location.

DRT-MAN-055 (Rev. 06) 78


② Available Icons

 Contains all of icons.

③ Add Shutter Icon

 Adds icons with user specified ROI Shutter Sizes.


 The following window appears with the click of the icon.

Figure 49. Add Sutter Size Window

④ Shutter Delete Icon

 Only deletes user added Shutter.

⑤ OK Icon

 Applies the modified tools arrangement and closes the window.

⑥ Cancel Icon

 Cancels and closes the window.

DRT-MAN-055 (Rev. 06) 79


6.1.3. Toolbar Icons

All of toolbar icons, noted in [Table 9].

Table 9. Toolbar Icons

Icon Description

Sets the ROI size to 8×10

Sets the ROI size to 10×12

Sets the ROI size to 14×17

Sets the ROI size to 17×17

Sets the ROI size to the user specified size

Sets the ROI into a square shape

Sets the ROI into a circular shape

Sets the ROI shape into a user specified shape

Displays the “R" marker on the screen

Displays the "L" marker on the screen

Displays the "ERECT" marker on the screen

Displays the "SUPINE" marker on the screen

Displays the "SITTING" marker on the screen

Displays the "STRESS" marker on the screen

Displays a user entered text on the screen

Displays the "PA" marker on the screen

DRT-MAN-055 (Rev. 06) 80


Displays the "AP" marker on the screen

Displays the "OBL" marker on the screen

Displays the "LAT" marker on the screen

Displays the "FLEX" marker on the screen

Displays the "EXT" marker on the screen

Displays the "↑" marker on the screen

Displays the "←" marker on the screen

Displays the "↓" marker on the screen

Displays the "→" marker on the screen

Arrange windows side-by-side symmetrically

Arrange windows up-and-down symmetrically

Rotates the image 90 degrees clockwise

Rotates the image 90 degrees counter-clockwise

Zoom-in and out of the image

Fits image to screen

Partially expands the image

Moves the image up/down/left/right

Displays the screen in 1×1

Displays the screen in 2×1

Displays the screen in 1×2

DRT-MAN-055 (Rev. 06) 81


Displays the screen in 2×2

Measures the length of the image

Measures the angle of the image

Verifies the DICOM Header information

Deletes any annotation or markers indicated on the image


using other tools

Adjusts the window level and width of the image

Inverts the image

Stitch images

Displays the histogram

Captures the image.

Prints the image.

Resets the edited image into its initial form

Deletes the image

Ruler calibration

Duplicate the image

Change mouse sensitivity

Run the dark scan manually(EVS-4343, EVS-3643 only)

Draw ellipse annotation

Draw rectangle annotation

DRT-MAN-055 (Rev. 06) 82


Draw polygon annotation

Draw free line annotation

Draw arrow annotation

Select annotation

DRT-MAN-055 (Rev. 06) 83


6.2. Projection List & Image Processing

Tab

The Projection List & Image Processing Tab can be used through the
tab icon on the upper-right corner.

Figure 50. Projection List (Left) & Image Processing Tab (Right)

DRT-MAN-055 (Rev. 06) 84


6.2.1. Projection List

Displays a list of studies categorized by projections.

Figure 51. Projection List Tab

① & ④ Projection and Position

 Projection can be selected by clicking ① icon.


 ④ presents the available positions of the selected projection.
 Allows verification of thumbnails, position designations, and
Receptor type.
POP-UP function
 When you click the mouse right button you can change the
options.
 ROI Marker visible : Set the default ROI and Marker visible
when the image comes from detector.
 Find auto position
∙ All projection : Find unexposed position among the all
projections When you save or send a image.
∙ One projection : Find unexposed position in the selected
projection when you save or send a image.

DRT-MAN-055 (Rev. 06) 85


∙ Do not apply : do not find unexposed postion when you save
or send a image.
② Projection Guide Icon

 The projection guide for the selected projection.

Figure 52. Projection Guide

 The presented projection guide may be closed using the left


click of the mouse.

③ Edit Projection Icon

 Please refer to 5.1.3 Edit Projection (p. 49) for detailed


information.

DRT-MAN-055 (Rev. 06) 86


6.2.2. Image Processing Tab

* Function for advanced users *


It is utilized to acquire a more appropriate image by adjusting the
post-process parameter of the completed image.

Figure 53. Image Processing Tab

① Histogram

 Displays the histogram of the currently selected image.


 Auto WL: Sets the window level automatically.

DRT-MAN-055 (Rev. 06) 87


② Image Enhancing Parameters

 Adjusts the image enhancing parameters.


 The adjustable parameters are as noted in [Table 10].

Table 10. Image Enhancing Parameters

Image Description
Processing
Contrast Adjusts the contrast
Edge Adjusts the Edge
Mask Adjusts the mask size
Bright Adjusts the brightness
Smooth Adjusts the smoothness

③ Parameter Function Icon

 Wizard
 Opens the multi-image viewer window.
 8 other types of images may be comprehended based on
the currently set parameter.
 Apply
 Applies the currently set parameter to the image.
 Reset
 Resets the parameter to its initial setting.
 Save
 Saves the currently set parameter and applies it to ensuing
imaging of the pertinent projection-position.

DRT-MAN-055 (Rev. 06) 88


6.3. Truview ART
* It is for advanced user.
It is works only EVS-3643, EVS3643 detector for sharpness

① Use TRUVIEW ART


Default value IS "OFF".
If you set "ON", it will be adjusted selected image.
② Magnified screen
It magnified selected position in the image viewer.
It can select using double click in the image viewer
③ Compare button
Compare with not adjusted/adjusted TRUVIEW ART.
2 image come up. Left image is not adjusted TRUVIEW ART, Right image
is adjusted TRUVIEW ART.
④ Save button
Save a TRUVIEW ART parameter in the Selected Position.
It will take more than 3 seconds when you adjust the TRUVIEW ART

DRT-MAN-055 (Rev. 06) 89


7. Configuration
Configures the user settings of EConsole1.

Administrator privileges are required for configuration.


Contents of configuration are saved and applied immediately following
changes.

Categories of Configuration are as noted in [Table 11].

Table 11. Configuration Category

Category Description
The tab (List/Exam) of EConsole1 may be viewed
simultaneously by division depending on the number of
Display
connected monitors, and performs relevant configurations.
Please refer to 7.1 Display (p. 92) for detailed information.
Allows configuration of language, date display, hospital
System information and etc.
Please refer to 7.2 System (p. 93) for detailed information.
Allows configuration of image storage folder, delete policy,
Image annotation information and etc.
Please refer to 7.3 Image (p. 99) for detailed information.
Performs configuration related to PC Storage (HDD).
Storage Please refer to 7.4 Storage (p. 107) for detailed
information.
Manages the accounts of EConsole1 users
Account Please refer to 7.5 Account (p. 112) for detailed
information.
Configures unnecessary RIS code filtering subsequent to
Block List ultrasound or other devices.
Please refer to 7.6 Block List (p. 113) for detailed

DRT-MAN-055 (Rev. 06) 90


Category Description
information.
Configures the DICOM Header Format.
Dataset Please refer to 7.7 Dataset (p. 114) for detailed
information.
Configures the network information, such as Local, PACS,
Printer and etc.
Network
Please refer to 7.8 Network (p. 115) for detailed
information.
Configures the Detector which will be connected with the
EConsole1.
Detector
Please refer to 7.9 Detector (p. 124) for detailed
information.
Configures the RIS Code.
RIS Code Please refer to 7.10 RIS Code (p. 129) for detailed
information.
Allows the configuration of projection and position.
Projection Please refer to 7.11 Projection Editor (p. 137) for detailed
information.

Configures the Generator which will be connected.


Generator Please refer to 7.12 Generator (p. 143) for detailed
information.

DRT-MAN-055 (Rev. 06) 91


7.1. Display

Figure 54. Display Configuration

Option Description

1 Monitor

Dual Monitors
* Caution: Unstable option. *

DRT-MAN-055 (Rev. 06) 92


7.2. System

 Performs configurations affecting the overall EConsole1.

Subcategories Description
Language Selects system language.
Date Selects date notation.
Enters the information of the institution using the
Institution
EConsole1
Enables and disables automatic running of
Options
EConsole1 at startup of Windows.
Edits the type and order of information presented
Worklist
in the Worklist.

DRT-MAN-055 (Rev. 06) 93


7.2.1. Language

Figure 55. Language Configuration Screen

 Configures the system language.


Items Description
Korean Set when you use the Korean window.
Chinese Set when you use the Chinese window.
Japanese Set when you use the Japanese window.
Portuguese Set when you use the Portuguese window.
Spanish Set when you use the Spanish window.
German Set when you use the German window.
Turkish Set when you use the Turkish window.
Swedish Set when you use the Swedish window.
French Set when you use the French window.
 DICOM character set
 Note that DICOM character set is defined separately from
system language.

DRT-MAN-055 (Rev. 06) 94


Items DICOM character set
Korean ISO IR 6\ISO 2022 IR 149
Chinese ISO IR 6\GB18030
Japanese ISO 2022 IR 13\ISO 2022 IR 87
Default ISO IR 100
Turkish ISO IR 148
Thai ISO 2022 IR 166
Ukrainian,
ISO IR 6\ISO IR 144
Russian
UTF-8 ISO IR 192

DRT-MAN-055 (Rev. 06) 95


7.2.2. Date

Figure 56. Date Configuration Screen

 Configures the date notation.


 Date
 Y: Year , M: Month, D: Day
 Delimiter
 Configures the symbol between Y, M, and D.
 Example) If today is May 31, 2012
Date Delimiter Final Notation
MM DD YYYY / 5/31/2012
MM DD YYYY - 5-31-2012
MM DD YYYY . 5.31.2012
YYYY MM DD / 2012/5/31
MM DD YY - 5-31-12
YY MM DD . 12.5.31

DRT-MAN-055 (Rev. 06) 96


7.2.3. Institution

Figure 57. Institution Configuration Screen

 Input the hospital/institution information using EConsole1.


 Hospital
 Hospital Name
 Department
 Department name within the hospital.

DRT-MAN-055 (Rev. 06) 97


7.2.4. Options

Figure 58. Options Configuration Screen

 Auto Start
 If checked, EConsole1 will automatically start when
Windows start.
 Virtual Keyboard
 If checked, virtual keyboard will be available for use.
 Auto Update
 Requires internet connection.
 If checked, EConsole1 will update automatically when a new
version is released.

DRT-MAN-055 (Rev. 06) 98


7.3. Image

 Allows configuration relevant to examed images.

Subcategories Description
Image Folder Sets the location to save the images.
Delete Option Sets delete options for image files.
Overlay Sets overlay on the images.
Import Imports images to the Studylist.

DRT-MAN-055 (Rev. 06) 99


7.3.1. Image Folder

Figure 59. Image Folder Configuration Screen

 Sets the location to save the images within PC Storage.


 Edit Icon
 Opens the folder selection window.
 Select the folder where the image is to be stored.

DRT-MAN-055 (Rev. 06) 100


7.3.2. Delete Option

Figure 60. Delete Option Configuration Screen

① Image Delete Option

 Use Password
 If checked, deletion of image requires a password.
 Use Reject Code
 If checked, a reject code (reason for deletion) is required
every time for an image file is deleted.

② Reject Code

 List of reasons for deletion.


 Statistics
 Displays the statistical record of each applied Reject Code.

DRT-MAN-055 (Rev. 06) 101


 The statistics can be exported to the Microsoft Excel file if
the Export Icon is clicked within the statistic display window.
 Delete
 Deletes the selected Reject Code from the list.
 Add
 Adds a new Reject Code.
 Edit
 Edits the selected Reject Code.

DRT-MAN-055 (Rev. 06) 102


7.3.3. Overlay

 Allows overlay configuration.

Figure 61. Overlay Configuration

 Allows editing of types of overlay to be displayed on the Left


Top, Right Top, Left Bottom, and Right Bottom.
 Editing method is the same while the display location differs.

Figure 62. Overlay Editing

DRT-MAN-055 (Rev. 06) 103


① Registered Overlay Type & Font Size

 Overlay: Information which will be displayed.


 Size: Font size of the pertinent information.
 Information is displayed in accordance with the arrangement
on the list.

② Edit Icon


 Adds a new overlay to the list.
 The following window as in [Figure 63] appears when the
icon is clicked.

Figure 63. Overlay Option Window

 The selected overlay is added after entering the size and


clicking ‘OK’.

DRT-MAN-055 (Rev. 06) 104



 Deletes the selected annotation from the list.


 The selected annotation is moved up one row.


 The selected annotation is moved down one row.


 Change font size of each location.

DRT-MAN-055 (Rev. 06) 105


7.3.4. Import

Figure 64. Import Configuration Screen

 Imports an external image into the Studylist.


 Import Icon
 Opens the file selection window.
 Select the image to be imported.

DRT-MAN-055 (Rev. 06) 106


7.4. Storage

 Configurations concerning the deletion and storage of PC


where the image will be saved.

Details Description
Configures the deletion and automatic
Delete deletion function of images stored on
Local Storage.
Compresses and backs-up the images
Backup
stored on Local Storage.

DRT-MAN-055 (Rev. 06) 107


7.4.1. Delete

 Configures the deletion and automatic deletion function of


images stored on Local Storage.

Figure 65. Delete Configuration Screen

① Storage Delete

 The ‘Delete’ Icon deletes all images stored on the Local Storage.
 Deleted images may not be restored, so please perform a
backup prior to deleting images!

DRT-MAN-055 (Rev. 06) 108


② Auto Delete

 Auto Delete
 If checked, all images satisfying the specified conditions are
automatically deleted from the PC Storage when the user
run a Econsole1.
 Disk Size
 If checked, images on the PC Storage are automatically
deleted once the disk space until remain storage is "Disk
Size".
 Configurable ‘Disk Size’ is meaning expected remain space
on PC storage.
 If remain storage is less than ‘Disk Size’, overflowed images
will be automatically deleted. (Whole disk volume except
‘Disk Size’ is allocated for Econsole1.)
 Max: Refers to the maximum limit of disk space utilized for
storage of images on the PC Storage.
 Period
 If checked, images on the PC Storage are continuously
deleted automatically during the set period.
 ex1) Set to "2", "Month" : Delete all images 2 month earlier
images based on the Today.
 ex2) Set to "1" "Day" : Delete all images 1 day earlier
images based on the Today.
 The cycle may be set by one of the following;
Day/Week/Month/Year.
One of the two methods, Disk Size and Period, may be selected
at a time.

DRT-MAN-055 (Rev. 06) 109


7.4.2. Backup

 Compresses and backs-up the images stored on Local Storage.

Figure 66. Backup Configuration Screen

① Database Backup Configuration

 Displays the location of the folder used in Data Backup.


 Edit
 Opens the selection window for the folder to be used in
backup.
 Compress
 Compresses then stores the currently used data based in
the selected folder.
 Restore

DRT-MAN-055 (Rev. 06) 110


 File selection window opens.
 Restores the selected database file and stores it in the
system.
 Backup
 Backs-up the currently used database in the selected folder.

② Automatic Backup Setting

 Auto Backup Check


 If checked, automatic backup is performed during the set
period below.
 Period
 Sets the automatic backup period.
 Available units consists of Day/Week/Month.

DRT-MAN-055 (Rev. 06) 111


7.5. Account

 Configures the account of the EConsole1 user.

Figure 67. User Account Configuration

 The currently registered user information is available on the list.


 Configures the user ID, Password, and authorization.
 Delete Icon
 Deletes the selected user account.
 Add Icon
 Adds a new user account.
 Edit Icon
 Edits the existing user account.

DRT-MAN-055 (Rev. 06) 112


7.6. Block List

 Filtering the unnecessary RIS code such as ultrasound or other


devices.

Figure 68. Block List Configuration

 The currently registered Block List information is available on


the list.
 Delete Icon
 Deletes the selected Block List entry.
 Add Icon
 Adds a new entry to the Block List.
 Edit Icon
 Edits the existing Block List entry.

DRT-MAN-055 (Rev. 06) 113


7.7. Dataset

 Configures the DICOM Header Format.

Figure 69. Dataset Configuration

① DICOM Header Item Configuration

 Deletes the unnecessary entries defined in the existing DICOM


Header Format (Full List).
 CR and DR are separately applied.
 Delete
 Deletes the selected entry.
 Reset
 Initializes the entry list back to Full List.
② Image format

 Configures the Image format information.

DRT-MAN-055 (Rev. 06) 114


7.8. Network

 Configures network information such as IP addresses.

Subcategories Description
Requires network connection.
Configures the network information of
Local
the PC (or Work Station) currently
operating EConsole1.
Requires network connection.
MWL Configures the network information of
the server storing the Modality Worklist.
Requires network connection.
Configures the network information of
Storage
the Storage Server, which stores the
image files.
Requires printer connection.
Printer Configures the connection information
of the printer.

DRT-MAN-055 (Rev. 06) 115


7.8.1. Local

 Configures the network information of the PC (or Work Station)


currently operating EConsole1.

Figure 70. Local Configuration Screen

 AE Title
 Enter the name of the local PC (or Work Station) which will
be displayed on the Network.
 IP
 Enter the IPv4 Address of the PC (or Work Station) currently
operating EConsole1.
 Port
 Enter the Port number.
 It should be configured in accordance with the server being
linked.
 Entered information will be automatically saved and applied.

DRT-MAN-055 (Rev. 06) 116


7.8.2. MWL

 Modality Worklist Server.


 Sets the server retrieving the patient list.

Figure 71. MWL Configuration Screen

① Information of server being accessed

 Manages the information of server being accessed.


 Comprised of AE Title(Access Server Name), IP, and Port
information.
 Test
 Verifies the connection with the selected server.
 Delete
 Deletes the selected server from the list.

DRT-MAN-055 (Rev. 06) 117


 Add
 Adds an access server.
 Edit
 Edits the selected server information.

② Option

 Time-out
 Response standby time with the server.
 It is regarded as connection failure if the server is
unresponsive for the set period of time.

③ Query

 Configures the automatic refresh setting of MWL.


 Auto
 MWL is automatically refreshed during the entered interval.
 Manual
 MWL refresh must be performed manually.
 Interval
 Sets the interval for automatic refresh.

④ Modality

 Select the modality type of the imaging equipment.


 Example) CR, DR
 Add
 Adds Modality.
 Delete
 Deletes the selected Modality.

DRT-MAN-055 (Rev. 06) 118


7.8.3. PACS

 Configures the Storage Server (PACS).

Figure 72. Storage Configuration

① Information of Storage Server to be Accessed

 Manages the information of access storage server.


 Comprised of AE Title (Access server name), IP, Port and
Selection information.
 If selection item is 'O', DICOM image send to it and the user
can select more than 1 PACS.
 Test
 Verifies the connection with the selected server.
 Delete
 Deletes the selected server from the list.

DRT-MAN-055 (Rev. 06) 119


 Add
 Adds an access server.
 Edit
 Edits the selected server information.

② Option

 Time-out
 Response standby time with the server.
 It is regarded as connection failure if the server is
unresponsive for the set period of time.

③ Query

 Time-out
 Response standby time with the server.
 It is regarded as connection failure if the server is
unresponsive for the set period of time.

DRT-MAN-055 (Rev. 06) 120


7.8.4. Printer

Figure 73. Printer Configuration Screen

① Printer Information & Printer Selection for Connection

 Manages the information of the printer to be connected.


 Selects the printer from the list.
 Add
 Adds a printer.
 Edit
 Edits the selected printer information.
 Delete
 Deletes the selected printer from the list.
 Test
 Verifies the connection with the selected printer.

DRT-MAN-055 (Rev. 06) 121


② Option

 Restricts the response time by the Printer.

③ Medium Type

 Selects the type of film.


 May select one between Clear Film and Blue Film.

④ Border

 Sets the color of the border line.


 May select one between Black and White.

⑤ Smoothing

 Applies Smoothing.
 May select one between Medium, Sharp and Smooth.

⑥ Magnification

 Sets the Magnification.

⑦ Density

 Adjusts the Gray-Level Scale.

⑧ Printer DPI

 Selects the resolution of the printer.

⑨ Overlay information

 Select the additional annotation information added on the film.

DRT-MAN-055 (Rev. 06) 122


 The following pop-up window in [Figure 74] appears when Edit
is clicked.

Figure 74. Printer Overlay Information Edit

 Instructions for use are identical with the overlay configuration of


the image.

Please refer to 7.3.3 Overlay (p. 103) for detailed information.

DRT-MAN-055 (Rev. 06) 123


7.9. Detector

 Performs detector related configurations.


 Performs Calibration Tool and Terminal Console programs.
Subcategory Description
Registers and edits the model of panel
(detector) being used.
General
Executes detector software, ECali1 (or
Caliview) and Terminal Emulator.
Detailed configuration screen
concerning Panel A, registered in
‘General’.
Panel A
Detailed configuration items for panel
are created in accordance with the
number of panels registered in ‘General’.

DRT-MAN-055 (Rev. 06) 124


7.9.1. General

 Registers and edits the panel (detector) which will be used.


 Executes detector software, ECali1 (or Caliview) and Terminal
Emulator.

Figure 75. General Configuration Screen

① Panel(Detector) Model Registration and Editing

 Registers the panel which will be connected.


 Add Icon
 Add icon registers the detector selected from Model Select.
 Edit Icon
 Edit icon replaces the currently registered detector with the
detector selected from the Model Select.
 Delete
 The most recently registered detector is deleted.

DRT-MAN-055 (Rev. 06) 125


② ECali1

 Run Icon executes the ECali1 (or Caliview) program.

③ Terminal

 Run Icon executes the Terminal Emulator.


 Please refer to Appendix B. Terminal Emulator (p. 150) for
detailed information.

DRT-MAN-055 (Rev. 06) 126


7.9.2. Detailed Configuration by Panel

 Performs detailed configuration for each panel(detector).


 A menu such as ‘Panel A’ and ‘Panel B’ are generated in
accordance with the number of panels registered in ‘General’.

Figure 76. Detector Detailed Configuration Screen

① Receptor

 Sets which Receptor type the detector will utilize.


 Stand, Table and Wireless mode are available.
 Only wireless detectors may utilize the Wireless mode.

② Model

 Model types of the detector.


 Automatically set by the value registered in ‘General’.

DRT-MAN-055 (Rev. 06) 127


③ Serial Number

 Enter the serial number of the Detector.

④ Grid Configuration

 Grid Type: Select type of grid.


 Line/Inch: Enter the line/inch value of the grid.
 Angle: Enter the angle value of the grid.

DRT-MAN-055 (Rev. 06) 128


7.10. RIS Code

 RIS (Radiology Information System) Code is a collection of


projections.
 For example, it configures contents such as “A, B, C regions are
to be imaged for RIS Codes for certain cancers.”
 It allows the rearrangement of sequence of projections.

Figure 77. RIS Code Configuration

 Import Excel Icon


 Adds the RIS Code value from an Excel fine.
 (Caution) Duplicate code values are overwritten with
contents of the Excel file. (Overwrites the existing data).

DRT-MAN-055 (Rev. 06) 129


 Delete Icon
 Deletes the selected RIS Code.
 Deletion of information part of the Code, such as the
projection, are executed by means of the ‘Edit’ icon.

 Edit Icon
 Manages the information, such as detailed projection
information and imaging environment, of the RIS Code.
 Please refer to 7.10.1. RIS Code (p. 131) for detailed
information.

DRT-MAN-055 (Rev. 06) 130


7.10.1. RIS Code Edit Window

Figure 78. RIS Code Edit Window

① RIS Code List Management

 Manages the code and provides description of RIS Codes.


 Text Box
 Are to write the Code and Description when adding or
editing the RIS Code.

 3 task icons are available. The descriptions are as noted in


[Table 12].

DRT-MAN-055 (Rev. 06) 131


Table 12. RIS Code List Management Icon

Icon Description
Edits the code and description of the RIS Code selected
from the list with the information entered in the text
box below the icon.

[Editing Sequence]
Edit 1) Selects the code to be edited from the list.
2) Enters in new information in the textbox below the
icon.
3) Clicks the Edit icon.
Adds the RIS Code with the information entered into the
textbox below the icon.

[Adding Sequence]
Add 1) Enters in new information in the textbox below the
icon.
3) Clicks the Add icon.
Deletes the RIS Code selected from the list.

[Deleting Sequence]
Delete 1) Selects the code to be deleted from the list.
2) Clicks the Delete icon.

② Editing of projections included in the RIS Code

 Manages the projections to be included in the selected RIS


Code.
 Descriptions concerning the task icons are as noted in [Table
13].

DRT-MAN-055 (Rev. 06) 132


Table 13. RIS Code Projection Management Icon

Icon Description
Both icons perform identical tasks.
, Adds the projections relevant to the selected
Add Projection/Position in the RIS Code.

Deletes the Projection category from the RIS Code.


Delete

Moves the selected Projection category up one


row.
Move up

Moves the selected Projection category down one


row.
Move down

③ Imaging Environment Configuration

 Enter the automatically configured environment value when


imaging of the pertinent RIS Code is performed.
 Patient Size
 Selects the patient size.
 4 levels of selections are available.
 AEC
 Sets the AEC.
 Grid
 Selects the Grid Type being used.
 May select one of None, Fixed and Moving.
 Focal Spot
 Sets the focus.
 May select from Large/Small.
 Density
 Sets the density.
 SID

DRT-MAN-055 (Rev. 06) 133


 Sets the distance between the Detector and X-ray Tube.
 kVp, mA, mAs(mSec)
 Sets the Generator condition.
 Parameter
 Locates the parameter file of the image processing which
will be applied after the imaging.
 Rotation
 Sets the rotation of the image.
 Flip H, Flip V
 Selects whether to flip the image horizontally or vertically.
 Shutter
 Selects the ROI Size.
 Marker
 Sets and manages the marker, which will be automatically
inserted in the image.
 Descriptions regarding the Marker Icon is as noted in [Table
14].
Table 14. Marker Icon

Icon Description
Adds a new Marker.
Please refer to 7.10.2 Marker Add Window (p.
Add 135) for detailed information.

Deletes the selected marker.


Delete

Moves the selected Marker up.


Move up

Moves the selected Marker down.


Move down

DRT-MAN-055 (Rev. 06) 134


7.10.2. Marker Add Window

Figure 79. Marker Add Window

 Location
 Select the location the marker will appear on the image
 Text
 Select the type of Marker
 Random texts may be used as a marker, aside from the text
which are provided by default
 User registered markers may be selected from the list
 The Marker list window may be edited using the Add Icon

DRT-MAN-055 (Rev. 06) 135


and Delete Icon
 If user want to change Maker size, Edit in 'Projection' - 'Marker
Size'.

DRT-MAN-055 (Rev. 06) 136


7.11. Projection Editor

 Manages the Projection type

Figure 80. Projection Editor Configuration

 Marker Size
 Change marker size.
 Rotation
 Set rotation selected receptor's all projection & position.
 Rotation's adapted order is each position's 'Flip Vertical',
'Flip Horizontal' is first and 'Rotation' is second.
 Delete
 Deletes the selected Projection or Position
 Recent selections which will be deleted by clicking the

DRT-MAN-055 (Rev. 06) 137


‘Delete’ icon are highlighted in yellow
 Edit Icon
 Edits the Projection and Position after opening the Project
Editor window.
 Please refer to 7.11.1 Projection Editor Window (p. 139)
for detailed information.

DRT-MAN-055 (Rev. 06) 138


7.11.1. Projection Editor Window

Figure 81. Projection Editor Window

① Anatomy

 Must be selected first


 Projection and position will not appear unless an
anatomical region is selected from the Anatomy
 Select the projection
 If the Receptor Type is different, even if the anatomical regions
are the same, it will be saved as a different setting
 Please be sure to set the anatomical region, as well as the
Receptor type.

DRT-MAN-055 (Rev. 06) 139


② Projection

Figure 82. Projection Configuration

 Manages the Projection list


 Please refer to [Table 15] for instructions of each icon

Table 15. Projection/Position List Management Icon

Icon Description
Edits the name of the selected category from the list
with the entry in the left textbox

[Edit Sequence]
1) Select the category to be edited from the list
Edit
2) Enter the new information in the textbox on the left
of the icon
3) Click the Edit icon
Adds the category with the information entered into the
textbox on the left of the icon

[Add Sequence]
Add 1) Enter the new information in the textbox on the left
of the icon
2) Click the Add icon

DRT-MAN-055 (Rev. 06) 140


Deletes the selected category from the list

[Delete Sequence]
Delete 1) Select the category to be deleted from the list
2) Click the Delete icon

Moves the selected projection category up one row in


the list
Move up

Moves the selected projection category down one row


Move in the list
down

③ Position

Figure 83. Position Configuration

 Manages the Projection list


 Please refer to [Table 15] for instructions concerning each icon

DRT-MAN-055 (Rev. 06) 141


④ Imaging Environment

 Sets the appropriate imaging environment for the selected


projection
 Detailed information concerning the Imaging Environment
Configuration are identical to the Imaging Environment
Configuration of the RIS Code Edit Window
 Please refer to ‘③ Imaging Environment Configuration’ of
7.10.1. RIS Code (p. 131)

DRT-MAN-055 (Rev. 06) 142


7.12. Generator

 Set the type of X-ray Generator


 Set detailed options for each type of X-ray Generator

Table 16. Generator Configuration Categories

Subcategories Details
Sedecal Sedecal Generator
DRGEM DRGEM Generator
POSKOM POSKOM Generator

DRT-MAN-055 (Rev. 06) 143


7.12.1. Sedecal

 Setting regarding the Sedecal Generator

Figure 84. Sedecal Configuration Screen

 ‘Use This Generator’ check box


 Check this category in order to use this Generator
 Enter the configuration value for the use of Sedecal Generator

DRT-MAN-055 (Rev. 06) 144


7.12.2. DRGEM

 For use of the DRGEM Generator

Figure 85. DRGEM Configuration Screen

 ‘Use This Generator’ check box


 Check this category in order to use this Generator
 Enter the configuration value for the use of DRGEM Generator

DRT-MAN-055 (Rev. 06) 145


7.12.3. POSKOM

 For use of the POSKOM Generator

Figure 86. POSKOM Configuration Screen

 ‘Use This Generator’ check box


 Check this category in order to use this Generator
 Enter the configuration value for the use of POSKOM Generator

DRT-MAN-055 (Rev. 06) 146


Appendix A. Glossary

Terms Description

Picture Archiving and Communication System.


PACS System for the storage, interpreting and access of
medical imaging information
Digital Imaging and Communication in Medicine.
DICOM
Standard medical digital image and communication
DICOM Directory.
DICOMDIR DICOM directory information file stored in the root
folder of the media (CD/DVD)
Hospital Information System.
HIS Hospital information system, registration/administrative
system, including OCS, PACS and etc.

OCS Order Communication System

Radiology Information System.


RIS
Operated as part of HIS or independently
Modality Worklist.
MWL DICOM standards for scheduled examination
information sharing
Computer Unified Device Architecture.
CUDA High sped parallel processing architecture utilizing a
GPU developed by NVIDIA
GPU Graphic Processing Unit.
Graphical User Interface.
GUI Computer interface for the user, developed by graphic
elements
Detector Flat Panel Digital X-ray Detector.
Program which converts source codes in high level
Compiler
language in to specific machine codes

DRT-MAN-055 (Rev. 06) 147


Terms Description

Process where the source code is being converted for


Build
computer operation
Application Programming Interface.
API Interface developed for use of specific functions in the
application program
Program utilized for the installation, maintenance and
Installer
removal of a specific application program
Process authenticating the user for permission to
Login
access the system
Coding
Style guideline for creating a source code
Convention
Code Process where developers inspect and verify the
Review created/edited source code
Code Tested number of code components/Total number of
Coverage code components * 100
Process of discovering potential defects of the
Static Code
program without operating it by analyzing the source
Analysis
code
Cyclomatic Digitized level of complexity of the program’s source
Complexity code
Continuous Integration.
Automated integration process of the source code, and
CI
the process of improvement and receiving feedback
through periodic build, test analysis
Encryption Encrypting the data
Protection
Protection preventing program hacking through
(Anti-
Reverse Engineering
Crack)
SCP Service Contents Provider
Text and various shapes marked on the completed
Annotation
image

DRT-MAN-055 (Rev. 06) 148


Terms Description

Lookup Table.
LUT
Table of previously calculated values
Region of Interest
ROI
Actual region necessary from the completed image
Exception subsequent to program error, wrong
Exception
memory reference or stack overflow
Calibration Task calibrating the quality of the detector image
Generic term for data files used for the calibration of
Map File
detector image quality
Pixel Map Data file used to calibrate bad pixels in detectors
Data file used to calibrate the property of the detector
Gain Map
subsequent to installation environment
Data file used to calibrate the property of the detector
Panel Map
panel itself

DRT-MAN-055 (Rev. 06) 149


Appendix B. Terminal Emulator
Usage of terminal emulator may differ from each detector, please
refer to the Detector Service Manual.

Terminal Mode

Terminal Emulator Start-up Sequence:

1. Turn the detector power OFF.


 Not necessary for F600.
2. Click ‘Run’ button on Configuration - Detector - General tab.

3. Turn the detector power ON.


4. When power is turned on, Terminal Emulator tries to connect to

DRT-MAN-055 (Rev. 06) 150


detector automatically.
 If not, please click ‘Connect’ button.
As the Ethernet Terminal Emulator features auto-connect function, it
will enter Terminal Mode automatically.

The TERMINAL MODE MENU has 3 options :

USER MODE Can be accessed by the user.

OPERATOR MODE Can be accessed only by the operator.

EXIT TERMINAL MODE Closes terminal mode.

DRT-MAN-055 (Rev. 06) 151


User Mode

To activate User Mode, enter “1” in the Terminal Mode menu screen.

Cautions: Number keys on numeric keypad in right-side don’t work


well. Please use number keys in left-side.

DRT-MAN-055 (Rev. 06) 152


User Mode has 8 options as below

Check the status of the internal module


1. EXECUTES SELF-TEST
in the detector

2. PROGRAM READY DELAY Check or change the Ready Delay value.

3. PROGRAM EXPOSURE Check or change the Exposure Window

WINDOW TIME Time value.

4. SELECT EXPOSURE Activate/deactivate the Exposure

PROTECTION MODE Protection Mode.

5. SELECT ADAPTIVE ERASE Activate/deactivate the Adaptive Erase

MODE Mode.

P. PREVIOUS MENU Return to the previous menu.

?. PRINT MENU Display all the options for User Mode.

X. EXIT TERMINAL MODE Exit terminal mode.

DRT-MAN-055 (Rev. 06) 153


1. EXECUTES SELF-TEST

To run the SELF-TEST, press”1” in User Mode.


If SELF-TEST is successfully completed, all the test results become
changed to “OK!”.

 If your detector has a problem with the operating temperature, you


will get a “Failed” answer for the current operating temperature. In
this case, you are advised to shut down the power to the detector
and allow a cooling time at least more than one hour.
If you still get the same error message after one hour of cooling,
then report your claim to the DRTECH Customer Support Team
(drtech@drtech.co.kr).
 If your detector has a problem with the "Erase Light" operation, you
will get a “Failed” answer. In this case, report your claim using our
claim form, CDN(Customer Dissatisfaction Notice / refer to the last
page in this Service Manual) to drtech@drtech.co.kr immediately.
Your detector should be returned to DRTECH for repair.

DRT-MAN-055 (Rev. 06) 154


 If your detector has a problem with Read/Write Memory operation,
you will get a “Failed” answer. In this case, report your claim using
CDN to cs@drtech.co.kr immediately.
 Your detector should be returned to DRTECH for repair.
 If your detector has a problem with the "Data Readout Sequence"
operation, you will get a “Failed” answer. In this case, report your
claim using CDN to drtech@drtech.co.kr immediately. Your detector
should be returned to DRTECH for repair.
 In all other cases, contact drtech@drtech.co.kr for technical support.

DRT-MAN-055 (Rev. 06) 155


2. PROGRAM READY DELAY

To change the Ready Delay value, press “2” in User Mode.


The current Ready Delay value and a message for setting a new Ready
Delay value are displayed.

 You can enter between 0 ~ 3000ms, the default value is 2000ms.

DRT-MAN-055 (Rev. 06) 156


To change the Ready Delay value, enter the new value you want and
new Ready Delay value will be displayed.
To keep existing setting just, press “Enter.”

 To return to the previous menu, press “P”.


 To see User menu, press”?”.

DRT-MAN-055 (Rev. 06) 157


3. PROGRAM EXPOSURE WINDOW TIME

To change the Exposure Window Time value, press “3” in User Mode.
The current Exposure Window Time value and a message for setting a
new Exposure Window Time value are displayed.

 You can enter between 0 ~ 3000ms and default value is 500ms.

DRT-MAN-055 (Rev. 06) 158


To change the Exposure Window Time value, enter the new value you
want and new Exposure Window Time value is displayed.
To keep the existing setting, press just “Enter.”


DRT-MAN-055 (Rev. 06) 159


4. SELECT EXPOSURE PROTECTION MODE

To change the Exposure Protection Mode setting, press “4” in User


Mode.
The current state of Exposure Protection Mode and a message for
setting a new value are displayed.

DRT-MAN-055 (Rev. 06) 160


To make the Exposure Protection Mode enable, press “1,” or disable,
press “2.”
To keep the existing setting, press just “Enter.”

The mode is changed successfully, and the current state will appear.


DRT-MAN-055 (Rev. 06) 161


5. SELECT ADAPTIVE ERASE MODE

To change the Adaptive Erase Mode setting, press “5” in User Mode.
The current state of Adaptive Erase Mode and a message for setting a
new value are displayed.

DRT-MAN-055 (Rev. 06) 162


To make the Adaptive Erase Mode enable, press “1,” or disable, press
“2.”
To keep the existing setting, press just “Enter.”

The mode is changed successfully, and the current state will appear.

 menu, press “P”.


DRT-MAN-055 (Rev. 06) 163


X. End of Terminal Mode

To exit the Terminal Mode, press “X” in the Terminal Mode menu or
User Mode.
After pressing “X,”
To confirm the exit, press “Y.”
To cancel the exit, press “N” to return to the previous menu.

DRT-MAN-055 (Rev. 06) 164


When pressing “Y” to confirm the termination of Terminal mode, the
Self-Test function of the detector will be executed automatically and
the results will be displayed.

Please check the detector operates normally.

Operator Mode

Operator mode is used for the detailed setting at the time of


producing detector for the first time, and can be accessed by only an
authorized operator.

DRT-MAN-055 (Rev. 06) 165


Appendix C. Update
If current using version has bugs please contact to CS team, CS team
will give you a update(patch) installer.

If you receive the update installer file please run the provided setup
file.

 Please back up original Econsole1 folder(ex: C:\Econsole1) in


order to prevent a fatal error.

If the setup file is run, you will be presented with the following screen.
Click ‘Next’ to start the installation.

DRT-MAN-055 (Rev. 06) 166


Select license protection type you purchased.

 Hardware License Protection (Dongle Key)


 Provides special USB, and you can run EConsole1 only when
the USB connected.
 Software License Protection
 Provides the license on the special PC.

DRT-MAN-055 (Rev. 06) 167


Do not change installation folder and click 'Next'.
It will update the program automatically and installation is finished
please run the Econsole1 and check the version.

DRT-MAN-055 (Rev. 06) 168


Appendix D. Portable function
Some of wireless detector is a function to save a x-ray image.
If user shot a x-ray without software the image will be saved in the
detector . The saved image control function is called "Portable
function".

Figure 87. Portable function summary

Econsole1 Vet's portable has 2 functions.


 Download the image saved in detector
 Register the exam order to detector

1) Download the image saved in detector.


Proceed in the following order
① Select a exam order and go to acquisition.

DRT-MAN-055 (Rev. 06) 169


② Click icon in the ToolBar
 If it is not in the toolbar, click the 'Edit' and add it.
③ Save portable image pop-up comes up.
 Select a image in the Detector.
 Click 'OK'.
Detailed function 'Save portable image' pop-up window is described in
the below.

Figure 88. Save portable image

① Select a image saved detector.


② Show selected detector's saved image's file name.
③ Selected image's preview image.
④ Function button and UI.
 Refresh
 Refresh a image list
 Delete

DRT-MAN-055 (Rev. 06) 170


 Delete selected image in detector.
 Delete all
 Delete all images selected detector.
 Used(%d)
 Selected detector's used storage.
 OK
 Get selected image and show it to Econsole1 Vet's
image viewer.
 Cancel
 Close 'Save portable image' window.

2) Register the exam order to detector


It is the function that save exam orders to detector and shot a image
without PC depending on the given exam list.

Save exam order function description is below.

① Click button.
② 'Save image list' window comes up.
 Select a detector.
 Select List in right side and click '<' button.
 Click 'Save' button then left side's list is save in the detector.

Detailed function 'Save image list' pop-up window is described in the


below.

DRT-MAN-055 (Rev. 06) 171


Figure 89. Save image list

① Select a detector.
② The list will be saved in detector.
③ Show Current work list.
④ function buttons.
 < Button
 Add a selected list.
 Delete
 Delete selected list.
 Delete all
 Delete all work list.
 UP/Down
 Change work list's order.
 Refresh
 Refresh work list.
 Set portable
 Change the detector's image acquisition mode to
portable mode.
 (Caution) If it is set to portable mode, Econsole1 vet

DRT-MAN-055 (Rev. 06) 172


and detector's connection will be disconnected.
If you want to connect Econsole1 Vet and detector,
Press 'AP' button on detector's side.
 Used(%)
 Selected detector's used storage.
 Save
 Save worklist in left side to detector.
 Cancel
 Close 'Save image list' window.

DRT-MAN-055 (Rev. 06) 173