ROOFING SYSTEM
two layers of waterproofing membrane, 4 mm thickness for
A4 each layer, 90 mm thick rigid insulation, separation sheet m2
geotextile 200gm/m², including forming cant strips, sheet
metal flashings and sealants as per specs and drawings. 135.95
DOOR SETS
44 mm thick hollow metal door including frame, European-
standard hardwares and as detailed on drawings &
specifications.
A10 Single leaf type door, size 800 x 2100 mm ( toilet ) No 5.00
A11 Single leaf type door, size 700 x 2100 mm ( toilet )Maid No
room 1.00
A12 Single leaf type door, size 700 x 1900 mm ( store ) No 1.00
A13 Sliding window, size 1200 x 1200 mm with security grills for No
ground floor. 4.00
A14 Sliding window, size 1200 x 920 mm for First floor. No 4.00
A15 Awning window, size 450 x450 mm, with security grills for No
ground floor. 2.00
A16 Awning window, size 450 x450 mm No 4.00
A17 Awning window, size 450 x 700 mm, for First floor.Study No
Room 1.00
A18 Sliding window, size 600 x 820 mm for Maid room. No 1.00
A19 Staircase window as per drawing 600 x 1200 mm No 1.00
DIVISION 9 - FINISHES
INTERNAL FINISHES
Finishings: Floors
Finishings: Ceiling
A24 m2
Metal strip suspended ceilings including suspension system. 41.76
Finishings: Walls
External Finishes
DIVISION 10 - SPECIALTIES
A39 Clear glass mirror with stainless frame size 450 x 750 mm No 6.00
A40 Clear glass mirror with stainless frame size 1100 x 1800 mm No 1.00
A41 Ref. RH, robe hook. No 6.00
A42 Ref. SD, liquid soap dispenser. No 1.00
A43 Towel bar (60cm) No 6.00
A44 Toilet paper holder No 6.00
A45 Soap dish No 6.00
Page 1 of 10
Material
ITEM DESCRIPTION UNIT QTY Material Installation Total Inst. Total
Cost
A46 Curtain bar (as per approved drawings) No 5.00
DIVISION 12 - FURNISHISINGS
Page 2 of 10
Material
ITEM DESCRIPTION UNIT QTY Material Installation Total Inst. Total
Cost
DIVISION 16 - ELECTRICAL
INTERNAL WORKS
CABLES
LIGHTING FIXTURES
Type F8
Industrial lighting fixture, wall mounted. Body is
made of glass reinforced polyester (GRP) in gray
no
color. Pretreated cold rolled sheet painted stove
enameled in white color inner tray, clear frosted
pattern acrylic molded diffuser. Fluorescent lamps
B4 2x36w 230v, 60Hz. IP65. Electronic Ballast 3.00 143.00 429.00 75.00 225.00 654.00
Type F16
Surface mounted indoor lighting fixture. Body of
pretreated CRS sheet painted and stove enameled in no
white color. Clear prismatic acrylic diffuser with
hinged latch cover fluorescent lamps, 2x36W, 230V,
B5 60Hz., Electronic Ballast 23.00 330.00 7590.00 119.00 2737.00 10327.00
Type F16R
Recessed mounted indoor lighting fixture. Body of
pretreated CRS sheet painted and stove enameled in no
white color. Clear prismatic acrylic diffuser with
hinged latch cover fluorescent lamps, 2x36W, 230V,
B6 60Hz. Electronic ballast 2.00 160.00 320.00 79.00 158.00 478.00
Type F21
Surface/Wall mounted indoor lighting fixture. Body
of pretreated CRS sheet painted and stove enameled no
in white color. Clear prismatic acrylic diffuser with
hinged latch cover fluorescent lamps, 2x18W, 230V,
B7 60Hz., Electronic Ballast 6.00 240.00 1440.00 111.00 666.00 2106.00
Type F21R
Recessed mounted indoor lighting fixture. Body of
pretreated CRS sheet painted and stove enameled in no
white color. Clear prismatic acrylic diffuser with
hinged latch cover fluorescent lamps, 2x18W, 230V,
B8 60Hz. Electronic ballast 6.00 158.00 948.00 84.00 504.00 1452.00
Type I4
Downlight lighting fixture, surface mounted. Body of
cylindrical spun aluminum pretreated, painted and
no
stove enameled in white. Symmetrical dome shaped
specular aluminum reflector with clear plain
tempered flat glass. Compact fluorescent lamps,
B10 2x26W 230V/60Hz. 2.00 143.00 286.00 75.00 150.00 436.00
Page 3 of 10
Material
ITEM DESCRIPTION UNIT QTY Material Installation Total Inst. Total
Cost
Type I9
Outdoor lighting fixture, wall mounted. Body made
of die-cast aluminum pretreated, painted and stove
enameled in white color. Aluminum reflector and no
clear prismatic pattern molded heat resistant glass
diffuser. Lamps: HPS 1x50W, 230V, 60Hz. Magnetic
B10 Ballast. 8.00 143.00 1144.00 75.00 600.00 1744.00
WIRING DEVICE
Supply, install and test wiring devices including all
necessary accessories as specified in
drawings,specifications and approved material.
B21 Single Pole Switch, 1 way, 1 gang. 230V,20A. no 11.00 9.50 104.50 9.00 99.00 203.50
Two Single Pole switch, 1 way, 2 gang (Ganged no
B22 together). 230V,20A. 11.00 15.40 169.40 12.00 132.00 301.40
B23 2 Way Switch, 1 gang. 230V,20A. no 3.00 8.70 26.10 9.00 27.00 53.10
Two Single Pole Switch, First Gang 1 Way, and no
B24 Second Gang 2 Way. (Ganged together). 230V,20A. 1.00 18.20 18.20 14.00 14.00 32.20
Two Way Switch, 2 way, 2 gang (Ganged together). no
B25 230V,20A. 2.00 13.70 27.40 11.00 22.00 49.40
Two Single Pole Switch, 1 way, 2 gang, (Ganged no
B26 together) (Weather Proof IP66) 230V,20A. 2.00 75.50 151.00 32.00 64.00 215.00
B27 Duplex Socket Outlet, 230V, 13A, Grounding Type no 12.00 14.25 171.00 10.00 120.00 291.00
B28 Single Socket Outlet, 230V, 13A, Grounding Type no 40.00 8.55 342.00 7.00 280.00 622.00
Single Socket Outlet, 230V, 13A, Grounding Type no
B29 (Weather Proof) IP66 4.00 70.50 282.00 40.00 160.00 442.00
Single Socket Outlet, 230V, 13A, Grounding Type no
B30 for clothes dryer & Washing Machine 2.00 9.50 19.00 6.00 12.00 31.00
Single Socket Outlet, 230V, 13A, Grounding Type no
B31 for Refrigerator. 1.00 9.50 9.50 6.00 6.00 15.50
Single Socket Outlet, 230V, 13A, Grounding Type no
B32 (Weather Proof) IP66, for Booster Pump. 1.00 70.50 70.50 40.00 40.00 110.50
Disconnect Switch for Window RAC, Non Fused & no
B33 with Pilot Light, 230V, 32A, 2P 10.00 14.90 149.00 11.00 110.00 259.00
Disconnect Switch for EWH 230V, 20A, 2P no
B34 Weatherproof IP66. 4.00 70.50 282.00 40.00 160.00 442.00
Disconnect Switch for EWH, Non Fused & with Pilot no
B35 Light, 230V, 32A, 2P 4.00 11.50 46.00 10.00 40.00 86.00
Disconnect Switch for Electric Range & Hood, Non no
B36 Fused & with Pilot Light, 230V, 32A, 2P 1.00 14.90 14.90 11.00 11.00 25.90
Page 4 of 10
Material
ITEM DESCRIPTION UNIT QTY Material Installation Total Inst. Total
Cost
Disconnect Switch for Lifting Pump Non Fused &
without Pilot Light, 230V, 20A, 2P Weatherproof no
B37 IP66. 1.00 70.50 70.50 40.00 40.00 110.50
POWER POINTS
Supply, install and test wall mounted power outlet
points including and all necessary accessories as
specified in drawings, specifications and as approved
material.
B38 Duplex and Single Socket Outlet Points. no 32.00 17.00 544.00 13.00 416.00 960.00
no
B39 Disconnect Switch Points ( for Window RAC, EWH) 14.00 35.00 490.00 26.00 364.00 854.00
B40 Power Point for MATV system no 1.00 26.00 26.00 19.00 19.00 45.00
Supply and install conduits in slab on grade &
below slab on grade including all necessary
accessories and materials for proper installation as
specified in drawings, specification and as approved
material.
B41 Duplex and Single Socket Outlet . no 28.00 17.00 476.00 14.00 392.00 868.00
Disconnect Switch (for Window RAC, EWH, no
B42 Range , Lifting Pump and Roll up shutter door ) 7.00 35.00 245.00 26.00 182.00 427.00
DISTRIBUTION BOARDS
Supply, install, terminate and test Lighting and power
panel boards as described on drawing, specification
and approved material.
LPG, 80A / 100A Main breaker, 42 sub-breakers, no
B43 earth leakage protection. 1.00 1950.00 1950.00 675.00 675.00 2625.00
OUTDOOR DISTRIBUTION BOARDS
GROUNDING
TELEPHONE POINTS
Page 5 of 10
Material
ITEM DESCRIPTION UNIT QTY Material Installation Total Inst. Total
Cost
INTERCOM SYSTEM WIRING DEVICE
Supply, install, terminate and test of a complete
intercom system including interface connection to
External Door Lock as shown in drawing and as
approved material.
Surface Audio Intercom Station Outdoor center, no
B50 weather proof 1.00 380.00 380.00 335.00 335.00 715.00
B51 Indoor unit no 3.00 0.00
B52 Door opener control unit no 1.00 140.00 140.00 100.00 100.00 240.00
Page 6 of 10
ITEM DESCRIPTION UNIT QTY Material Material Cost Installation Total Inst. Total
DIVISION 15 - MECHANICAL
PLUMBING INSTALLATION
C17 Ø 1/2" dia lines. (Plus 20%) Lm 0.60 7.52 4.51 20.00 12.00 16.51
C18 Ø 1" dia lines. (Plus 20%). Lm 8.06 12.69 102.33 28.00 225.76 328.10
C19 Ø 1-1/4" dia lines. (Plus 20%). Lm 2.46 16.92 41.62 35.00 86.10 127.73
C20 Ø 1-1/2" dia lines. (Plus 20%) Lm 2.64 20.40 53.86 38.00 100.33 154.19
C21 Ø 2" dia lines. (Plus 20%). Lm 2.70 26.79 72.33 44.00 118.80 191.14
C22 Ø 3" dia lines. (Plus 20%) Lm 19.18 50.76 973.37 71.00 1,361.42 2,334.79
Page 7 of 10
ITEM DESCRIPTION UNIT QTY Material Material Cost Installation Total Inst. Total
CPVC pipes sched 80, S/J for hot water lines inside
villa for toilet branches, & condensate drain ,and
above ceilings, inside slabs. All pipes complete with
insulation, protections, fittings, supports and
accessories as specified:
In shafts , above ceilings, roof, upper roof:
C23 Ø 1/2" dia lines.(Plus 20%) Lm 14.04 6.66 93.51 17.00 238.68 332.18
C24 Ø 3/4" dia lines.(Plus 20%) Lm 4.80 9.08 43.58 19.00 91.20 134.78
C25 Ø 1" dia lines.(Plus 20%) Lm 33.54 13.32 446.75 23.00 771.32 1,218.07
C26 Ø 1-1/4" dia lines.(Plus 20%). Lm 20.06 18.67 374.59 28.00 561.79 936.39
C27 Ø 1-1/2" dia lines.(Plus 20%). Lm 21.72 22.51 488.92 33.00 716.76 1,205.68
C28 Ø 2" dia lines.(Plus 20%) Lm 1.62 31.53 51.08 41.00 66.42 117.50
CPVC pipes sched 80, S/J for hot water lines inside
villa for toilet branches, & condensate drain ,and
above ceilings, inside slabs. All pipes complete with
insulation, protections, fittings, supports and
accessories as specified:
Above ceiling:
C29 Ø 1/2" dia lines. (Plus 20%) Lm 12.05 6.66 80.24 17.00 204.81 285.05
C30 Ø 3/4" dia lines. (Plus 20%) Lm 25.92 9.08 235.35 19.00 492.47 727.83
In shaft:
C31 Ø 3/4" dia lines. (Plus 20%) Lm 14.64 9.08 132.93 19.00 278.16 411.09
C32 Ø 1" dia lines. (Plus 20%) Lm 5.28 13.32 70.33 23.00 121.42 191.75
CPVC under ground pipes sched 80, or class V, S/J
for cold water service mains lines, transfer line and
complete with all required fittings, supports,
accessories, insulation and protections, as specified
C33 Ø 1-1/4" dia lines. (Plus 20%) Lm 4.56 18.67 85.14 28.00 127.68 212.82
C34 Ø 1-1/2" dia lines. (Plus 20%). Lm 17.88 22.51 402.48 33.00 590.04 992.52
C35 Ø 1-1/2" dia lines. (Plus 20%) Lm 9.36 22.51 210.69 33.00 308.88 519.57
Galvanized Steel pipes sched 40, ASTM A53 for cold
water service mains lines, transfer line and complete
with all required fittings, supports, accessories,
insulation and protections, as specified.
C36 Ø 1-1/4" dia lines. Lm 0.78 16.92 13.20 35.00 27.30 40.50
C37 Ø 1-1/2" dia lines. Lm 7.98 20.40 162.79 40.00 319.19 481.98
C38 Ø 2"/3" mm outlet No. 7.00 7.50 52.50 41.00 287.00 339.50
C39 150 x 150 mm chrome plated cover. No. 8.00 174.60 1396.80 70.00 560.00 1,956.80
Galvanized body roof Vent Caps and all related
accessories.
C40 Ø 75 mm dia. No. 5.00 136.00 680.00 68.00 339.99 1,019.99
Page 8 of 10
ITEM DESCRIPTION UNIT QTY Material Material Cost Installation Total Inst. Total
Ball Valve 1/2" for Hose BiB
C48 Ø 20 mm, 1/2" dia. No. 2.00 39.20 78.40 49.00 97.99 176.39
C64 EF Capacity 168m3/hr, wall mounted No. 2.00 120.00 240.00 80.00 160.00 400.00
C65 EF Capacity 168m3/hr, Ceiling mounted No. 5.00 285.00 1425.00 100.00 500.00 1,925.00
C66 Kitchen hood Capacity 530m3/hr No. 1.00 489.00 489.00 200.00 200.00 689.00
C67 Capacity 24000 btu, hot and cold No. 8.00 1299.00 10392.00 342.00 2,735.98 13,127.98
C68 Capacity 18000 btu, hot and cold No. 2.00 1074.00 2148.00 307.00 614.00 2,762.00
Page 9 of 10
SANG BOQ SUMMARY: SOLDIER VILLA
Total Cost
Proposed
Civil -
Electrical 40,200.67
Mechanical 79,749.80
TOTAL 119,950.47