Professional Documents
Culture Documents
Calculation of Moment of Inertia of Pipe and Allowable Bending Inside Piping
Calculation of Moment of Inertia of Pipe and Allowable Bending Inside Piping
1400 NB pipe
symbol Details Formula value
F Load in kgs 324300
r moment arm in m 1.655
M Moment in kg m M=F xr 536716.5
D Outside diameter of pipe in cms 143.2
d Inside diameter of pipe in cms 140
I Moment of Inertia in cm4 I = ∏/64(D^4 -d^4) 1784355.49
fa allowable bending stress kg/cm2 From 0.66 fy 1682
y Dim.of ext fibre form NA y=D/2 71.6
fb Actual bending stress in kg/cm2 f = M x y/I 2153.657
As the allowable bending stress is higher in value than actual bending stress
The force effect requires force to be
750 NB pipe
symbol Details Formula value
F Load in kgs 324300
r moment arm in m 1.655
M Moment in kg m M=F xr 536716.5
D Outside diameter of pipe in cms 76
d Inside diameter of pipe in cms 75
I Moment of Inertia I = ∏/64(D^4 -d^4) 84517.39
fa allowable bending stress kg/cm2 From 0.66 fy 1682
y Dim.of ext fibre form NA y=D/2 38
fb Actual bending stress in kg/cm2 f = M x y/I 24131.396
As the allowable bending stress is higher in value than actual bending stress
The force effect does not affect.