VE Bus BMS Example With 3KW 12V MultiPlus 230 Volt Revision B
VE Bus BMS Example With 3KW 12V MultiPlus 230 Volt Revision B
CCGX POWER +
CCGX 1A
CCGX POWER + victron energy
5x20mm V+ ! i IP43 BLUE POWER
Absorbtion
PV 100Vmax 50A
SHORE POWER
Float
Bulk
color control
BATTERY PV
ISOLATION TRANSFORMER OR
BMS ON/OFF GALVANIC ISOLATOR SHOULD BE
+ - - + INSERTED HERE IF NEEDED,
INCLUDING NECESSARY
BMS POWER+ BREAKERS.
BMS LOAD DISCONNECT
MAIN SWITCH-1
VE.Direct
ETHERNET
VE.Direct-2
VE.Direct-1
VE.Bus
BMS CHARGE DISCONNECT
name GENERATOR
ALARM LED - OFF VRM
WORLD
0 OFF 0 OFF
POSITIVE POSITIVE
BUSBAR BUSBAR
30 AC
CYRIX Li www.victronenergy.com ENGINE SYSTEM
ANL
CHARGE
230 MEGA
100A Alternator+
175A FUSE
POS. NEG. xx AMP.
ENERGIZE OUTPUT-2 OUTPUT-1 INPUT GROUND
FROM ENGINE+(30)
40 AMPERE
285040F
A
B
T
D
A
L
175A
SE
T MPPT+ Argo Fet 5A FUSE
RE
BMS 2A OFF
BMV 100mA
Spare
MultiPlus Batt +
5x20mm AC POWER SOURCE MAIN INCOMING
FUSES ON
MEGA
400A
MULTIPLUS 3KW/12V/230V AC CHANGE OVER SWITCH AC BREAKERS
MultiPlus Batt +
INVERTER/CHARGER
BTV CABLE BTV CABLE CENTRAL NEGATIVE BUSBAR victron energy 0 OFF 0 OFF 0 OFF 0 OFF
BLUE POWER
charger inverter
mains on inverter on
AC in 1 AC out 1 I on
bulk overload
O off
CYRIX LI- AC in 2 AC out 2
absorption
float
charger only
low battery
temperature
SUPPLIED UTP CABLE
BP220 GND- .battery charger .sinewave inverter .transfer switch
Battery
.powerassist .parallel .three phase
CCGX- connectable
VOLT
12 |3000 |120
AMP
VA
VE.Bus-1 VE.Bus-2
Load-
BATTERY
Load-
BATTERY
victron energy
BLUE POWER
Mains detector
_ _
NOT IN USE
VE.Bus BMS
MPPT- L N G L N G L N BATTERY
+ +
3 x Lithium
12.8V-100Ah
12.8V-100Ah
12.8V-100Ah
BATTERY
Smart LiFePO4
Smart LiFePO4
Smart LiFePO4
Lithium
Lithium
Lithium
NEUTRAL
NEUTRAL
NEUTRAL
GROUND
GROUND
LINE
LINE
LINE
Engine/Starter Battery-
12.8V-100Ah
AC IN-1 AC OUT-1 AC OUT-2 ON
AC DISTRIBUTION
victron energy
victron energy
victron energy
1 2
+ - + - + - + - S1 S2 + NC NO COM NC NO COM + -
T-SENSE AUX1 AUX2 GND TRICKLE K1 K2 V-SENSE
RELAY CHARGE
BLUE POWER
BLUE POWER
1 N 1 N
MultiPlus Batt-
name name name name name name name name
MultiPlus Case GR Conn-A AC IN
ADxxxxx xxA/I n0.03A
T
ADxxxxx xxA/I n0.03A
T
Bx test regularly Bx test regularly
Conn-C AC OUT-1
MCB/RCD MCB/RCD
VE.Bus CCGX
+B2 Starter Battery + VE.Bus mains detector 2 N 2 N
+B1
Conn-G Batt+
MULTIPLUS MULTIPLUS
Conn-G Batt+ OUTPUT-1 OUTPUT-2
THE BMV SHUNT IS MOUNTED
DIRECT ON BOTH BUSBARS Conn-F Batt-
KEEP NEGATIVE BATTERY CABLES
ALL AT THE SAME LENGTH ! Drawing BJE-256B Conn-F Batt-
No Break load-1
Conn-L Case ground No Break load-2
No Break load-3
Switched load-1
Switched load-2
Switched load-3
Smart BatteryProtect programming Recommended AC Out-2 cable/breaker size MultiPlus Recommended AC Out-1 cable/breaker size MultiPlus Recommended DC cable/fuse size MultiPlus Recommended AC IN WARNING
cable/breaker size MultiPlus
The BatteryProtect must be programmed AC Out-2 only is available when power is With Power assist the MultiPlus can add 0-5 m cable length: 4 x 50SQmm 230 VOLT IS EXTREMELY HAZARDOUS
for Li-Ion mode and 12 Volt either through present on AC IN. During battery operation 3KW to the output load when needed. 5-10 m cable length: 4 x 70SQmm AC IN must be protected by a circuit DO NOT TOUCH ANY LIVE WIRED
programming on the device itself or with a it will be disconnected. Together with the adjustable 50A input this Cable length stands for the distance between the breaker rated at 50A max or less. This PARTS OF THE INSTALLATION !!!
Bluetooth enabled smartphone or tablet. AC Out-2 supports up to 16A. all adds up to the max sum of input and battery and the MultiPlus connections !!! depends heavily on the size of the WHEN IN DOUBT, ALWAYS CONSULT
Connect the load disconnect output of the An Earth leakage device with breaker or a output current of 50+13=63A. An Earth Recommendations are without other loads in the connected power source.The input currents YOUR VICTRON DEALER !!!
VE.Bus BMS to Remote H terminal. combination MCB/RCD must be installed leakage device with breaker or a system and these also should be taken into must be adjusted to fit the size of the
on the output. Cable size must be adjusted combination MCB/RCD must be installed account for proper main battery, main fuse & main connected power source. The breaker and
accordingly. on the output. Cable size must be adjusted switch cables !!! cable size for AC IN should be adjusted
accordingly. Fuse size should be 1 x 400A accordingly.