Fan Motor (Hydraulic Oil Cooler) - Test - Measurement of


Case Drain Oil
SMCS - 5058-081-FM

Table 1
Required Tools
Part Number Description Qty
6V-9829 Cap As 1
Container for measuring 1

NOTICE

Care must be taken to ensure that fluids are contained during


performance of inspection, maintenance, testing, adjusting and repair
of the product. Be prepared to collect the fluid with suitable containers
before opening any compartment or disassembling any component
containing fluids.

Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop


Products Guide" for tools and supplies suitable to collect and contain
fluids on Caterpillar products.

Dispose of all fluids according to local regulations and mandates.

Note: The fan motor speed must be set to the correct specification before performing this test.
Refer to Testing and Adjusting, "Fan Motor Speed (Hydraulic Oil Cooler) - Test and Adjust".

1. Position the machine on level ground.

2. Stop the engine.

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 24/01/2013
330C L Excavator DKY00001-UP (MACHINE) POWERED BY C-9 Engine(SEBP... Página 2 de 3

3. Release the pressure in the hydraulic system. Refer to Testing and Adjusting, "Hydraulic
System Pressure - Release".

Illustration 1 g00845980

(1) Fan motor

(2) Case drain hose

Illustration 2 g00845985

(2) Case drain hose

(3) Case drain filter

4. Disconnect case drain hose (2) from case drain filter (3). Install 6V-9829 Cap As on the
open fitting of case drain filter (3) .

5. Place the end of drain hose (2) into the container in order to measure the case drain oil.

6. Start the engine.

7. Place the machine controls at the following settings: AEC switch OFF and engine speed dial
"10".

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 24/01/2013
330C L Excavator DKY00001-UP (MACHINE) POWERED BY C-9 Engine(SEBP... Página 3 de 3

Reference: Refer to Testing And Adjusting, "Engine Performance - Test" for engine rpm
settings.

8. Measure the amount of case drain oil for one minute.

Table 2
Case Drain Oil
Fan Speed Amount of Case Drain Oil

1200 rpm (1)


1.1 L/min (0.29 US gpm)

1340 rpm (2)


1.3 L/min (0.34 US gpm)
( 1 )
Standard specification
( 2 )
High ambient specification

Copyright 1993 - 2013 Caterpillar Inc. Thu Jan 24 15:19:36 UTC-0400 2013
Todos los derechos reservados.
Red privada para licenciados del SIS.

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 24/01/2013
330C L Excavator DKY00001-UP (MACHINE) POWERED BY C-9 Engine(SEBP... Página 1 de 4

Cerrar SIS

Pantalla anterior

Producto:  EXCAVATOR
Modelo:  330C L EXCAVATOR DKY
Configuración: 330C L Excavator DKY00001-UP (MACHINE) POWERED BY C-9 Engine

Pruebas y Ajustes
330C Excavator Hydraulic System
Número de medio -RENR5435-07 Fecha de publicación -01/03/2011 Fecha de actualización -18/03/2011

i01861575

Fan Motor Speed (Hydraulic Oil Cooler) - Test and Adjust


SMCS - 5058-036-FM

Table 1
Required Tools
Part Number Description Qty
9U-7400 Multitach Tool Group 1

Illustration 1 g00846010

Engine compartment (rear)

(2) Delivery line

(3) Line to relief valve (fan pump)

(33) Fan pump

NOTICE

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 24/01/2013
330C L Excavator DKY00001-UP (MACHINE) POWERED BY C-9 Engine(SEBP... Página 2 de 4

Care must be taken to ensure that fluids are contained during


performance of inspection, maintenance, testing, adjusting and repair
of the product. Be prepared to collect the fluid with suitable containers
before opening any compartment or disassembling any component
containing fluids.

Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop


Products Guide" for tools and supplies suitable to collect and contain
fluids on Caterpillar products.

Dispose of all fluids according to local regulations and mandates.

Test
1. Position the machine on level ground.

2. Stop the engine.

3. Release the pressure in the hydraulic system. Refer to Testing And Adjusting, "Hydraulic
System Pressure - Release".

4. Install 9U-7400 Multitach Tool Group on the fan for the hydraulic oil cooler.

5. Start the engine.

6. Place the machine controls at the following settings: AEC switch OFF and engine speed dial
"10".

Reference: Refer to Testing And Adjusting, "Engine Performance - Test" for engine rpm
settings.

7. Increase the hydraulic oil temperature to 55° ± 5°C (131° ± 9°F).

8. Read the fan speed. Refer to Table 2 for the correct speed.

Table 2
Fan Speed
1200 ±10 rpm (1)
1340 ±10 rpm (2)
( 1 )
Standard specification
( 2 )
High ambient specification

9. If the fan speed is not within the specification, adjust the relief valve for the fan pump.

Adjust

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 24/01/2013
330C L Excavator DKY00001-UP (MACHINE) POWERED BY C-9 Engine(SEBP... Página 3 de 4

Illustration 2 g00846018

Pump compartment

(34) Pressure tap

(35) Relief valve (fan pump)

(36) Locknut

(37) Adjustment screw

1. In order to adjust the relief valve pressure setting for the fan pump, loosen locknut (36) and
turn adjustment screw (37) .

Note: Turn adjustment screw (37) clockwise in order to increase the pressure. Turn
adjustment screw (37) counterclockwise in order to decrease the pressure.

Note: A quarter turn of the relief valve changes the pressure approximately 3300 kPa (480
psi).

Note: Always make final pressure adjustments on pressure rise.

2. Adjust the relief valve pressure to the specifications in Table 3.

Note: In order to avoid hydraulic component damage, adjust the fan speed within the
specifications in Table 3.

Table 3
Fan Speed Relief Valve Pressure

1200 ±10 rpm (1)


8800 kPa (1275 psi)

1340 ±10 rpm (2)


11100 kPa (1610 psi)
( 1 )
Standard specification
( 2 )
High ambient specification

3. Tighten locknut (36) to a torque of 10 ± 1 N·m (7 ± 0.5 lb ft).

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 24/01/2013
330C L Excavator DKY00001-UP (MACHINE) POWERED BY C-9 Engine(SEBP... Página 4 de 4

Copyright 1993 - 2013 Caterpillar Inc. Thu Jan 24 15:20:43 UTC-0400 2013
Todos los derechos reservados.
Red privada para licenciados del SIS.

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 24/01/2013

You might also like