You are on page 1of 2

Project : Design by :

LOGO
Owner : Mark : CombFooting
Location : Date : 2/12/2021
Check by : Engr. Ruel H. Cepeda

Material Properties Column Properties: Footing Properties: Reinforcement Details:


Concrete f'c = 20.70 Mpa Exterior Col. to Col. Distance = 3.20 m Location #
Reinforcing fy = 414.00 Mpa Width = 0.40 m Width = 2.00 m Top Bar Dia = 16.00
Height = 0.40 m Thickness = 0.25 m Bot Bar Dia = 16.00
Soil Properties: Edge to Face Dist = 0.60 Free Depth = 1.80 m Cover (mm) = 75.00
σall= 240.00 kPa Interior
γ= 18.00 kN/m3 Width = 0.35 m
Height = 0.35 m
Edge to Face Dist = 0.60 Free
Applied forces:
Pu Mx Fx Pu Mx Fx qa
Service kN kN.m kN Factore kN kN.m kN factor
Exterior = 138.78 6.24 15.27 Exterior = 181.64 49.39 14.82 1.00
Interior = 311.89 26.33 11.30 Interior = 324.37 47.61 58.90

3D Zoom In Zoom Out 2D

0.4 m

0.35 m
117.74 kPa

2m
117.74 kPa 0.4 m 0.35 m
46.62 kPa

46.62 kPa
4.775 m

Summary Calculations
Check for Soil Pressures (Service Load)
Footing Shear and Moment Diagram
Location Value Unit
400.00
Exterior Footing = 46.62 kPa
Interior Footing = 117.74 kPa 300.00

Ratio 0.49 Safe


200.00
Check for Stability (Service Load)
100.00
Overturning Sliding
x-x 0.00
x-x
Resisting Overturning 0.00 0.96 1.91 2.87 3.82 4.78
-100.00
2,212.29 39.21338296 Ratio
56.42 17.51 -200.00
Safe Safe
-300.00
Moment Shear

Check for Shear Design (Factored Load)


Check Wide Beam Shear Check Punching Shear
-Side +Side Units Exterior Column Unit Interior Column Unit
Exterior Column 0.20 0.55 Mpa Unbalance Moment factor = 0 0
Interior Column 0.05 - Mpa Column Location Factor = 40.00 40.00
Absolute max. Stress = 0.550 MPa ColumnAspect Ratio = 1.00 1.00
Under-strenght φ Factor = 0.75 Actual Punching Stress = 0.45 MPa 0.84 MPa
Allowable Shear Capacity = 0.580 MPa Allowable Shear Capacity = 1.13 Mpa 1.13 Mpa
Ratio 0.948 Safe Ratio 0.40 Safe 0.74 Safe

This spreadsheets is licensed only to

Engr. Ruel H. Cepeda


Detailed Calculations
Check for Stability (Service Load) Check for Shear (Factored Load)
Overturning about x-x Punching Shear (Exterior Column) Punching Shear Interior Column)
Exterior Column Vu at critical point Vu at critical point
Moment = 6.24 kN-m Point 1 = 74.79 kN Point 1 = 275.85 kN
Shear Force = 15.27 kN Point 2 = 187.64 kN Point 2 = 113.45 kN
Total = 10.06 kN-m Average = 131.21 kN Average = 194.65 kN
Interior Column Calculation of unbalanced moment transferred by Calculation of unbalanced moment transferred by
Moment = 26.33 kN-m eccentricity of shear eccentricity of shear

Shear Force = 11.30 kN β= 1.00 ACI 11.11.2.1.a β= 1.00 ACI 11.11.2.1.a


Total = 29.15 kN-m αs = 40.00 ACI 11.11.2.1.b αs = 40.00 ACI 11.11.2.1.b
Resisting about x-x b1 = 0.56 m b1 = 0.51 m
Footing Weight = 57.30 kN b2 = 0.56 m b2 = 0.51 m
Soil Weight = 300.27 kN bo = 2.24 m bo = 2.04 m
Ext. Axial = 138.78 kN Critical Area = 0.31 mm2 Critical Area = 0.26 mm2
Int. Axial = 311.89 kN Resultant = 131.21 kN Resultant = 194.65 kN
Total = 2,212.29 kN-m γf = 0.60 x-x ACI 13.5.3.2 γf = 0.60 x-x ACI 13.5.3.2
Ratio 56.42 γv_x = 0.40 x-x ACI 11.11.7.1 γv_x = 0.40 x-x ACI 11.11.7.1
2
Remark = Safe J/c 1= 0.0678 N/mm x-x J/c 1= 0.0565 N/mm2 x-x
Sliding Calculation Vu = 0.45 ACI 11.11.5.2.a Vu = 0.84 ACI 11.11.5.2.a
kp = 2.78 φVu = 1.13 ACI 11.11.5.2.b φVu = 1.71 ACI 11.11.5.2.b
Pressure mid d = 96.25 kPa Calculation of RC punching shear resistance without shear Calculation of RC punching shear resistance without
Passive Force = 48.13 kN reinforcement (φVn = φVc) shear reinforcement (φVn = φVc)
2 2
Friction force = 416.98 kN Vc (N/mm ) = 2.32 ACI 11.11.2.1.a Vc (N/mm ) = 2.32 ACI 11.11.2.1.a
2 2
Safe Factor = 17.51 Vc (N/mm ) = 1.83 ACI 11.11.2.1.b Vc (N/mm ) = 1.93 ACI 11.11.2.1.b
Remark = Safe Vc (N/mm2) = 1.50 ACI 11.11.2.1.c Vc (N/mm2) = 1.50 ACI 11.11.2.1.c
2 2
φVc (N/mm ) = 1.13 φVc (N/mm ) = 1.13
Check for Soil Pressure (Service Load) Ratio = 0.404 Ratio = 0.747
Soil Pressure Remark = Safe for punching shear! Remark = Safe for punching shear!
Footing Weight = 57.30 kN Check for Reinforcement (Factored Load)
Soil Weight = 300.27 kN Along Longitudinal direction
Resisting Force = 784.82 kN Exterior Column Exterior Column
Eccentricity = (0.34) kN-m Edge Left Right MidSpan Left Right Edge Unit
Exterior Footing = 46.62 kPa Mu = - 25.76 49.99 161.24 62.31 34.80 - kN.m
Interior Footing = 117.74 kPa Ru = - 0.566 1.098 3.543 1.369 0.765 - MPa
Ratio 0.49 Safe m= 23.529 23.529 23.529 23.529 23.529 23.529 23.529
req'd p = - 0.0014 0.0027 0.0097 0.0034 0.0019 -

Check for Shear (Factored Load) min p = 0.0034 0.0034 0.0034 0.0034 0.0034 0.0034 0.0034

Wide Beam Shear use p = - 0.0019 0.0034 0.0097 0.0034 0.0025 -


2
Shear Forces calculated as the volume of As = - 589 1,075 3,071 1,096 801 - mm
bearing pressures req'd n2 = - 3 6 16.00 6.00 4.00 - pcs
Exterior Column Use n2 = 10.00 10.00 10.00 16.00 10.00 10.00 10.00
-Side 0.200 MPa s (mm) = 182.22 182.22 182.22 102.93 182.22 182.22 182.22 OK!
+Side 0.550 MPa Location Bottom Bottom Top Top Bottom Bottom Bottom
Interior Column
-Side 0.050 MPa Along Transverse direction
+Side - MPa Column Exterior Interior
Maximum Stress = 0.550 MPa Mu = 63.07 71.11

Ultimate Shear Capacity Ru = 1.386 1.563


Vc = φ0.166λ√f'c - ACI 22.5.5.1 m= 23.529 23.529
Reduc factor φ = 0.750 use p = 0.00349 0.00396
λ= 1.000 As = 311 321

Vc = 0.580 MPa req'd n1 = 3.00 3.00


Ratio = 0.948 s (mm) = 156.00 131.00
Remark = Safe for beam shear!
This spreadsheets is licensed only to

Engr. Ruel H. Cepeda