Professional Documents
Culture Documents
Common SR 2014-
Common SR 2016-17 in Rs New Ford Price in Rs
Sl Item Material 15 in Rs FORD
Name of the Material UoM FORD Rates inclusive of duties Including GST wef
No No Code Rates inclusive of
taxes & F&I up to 30.06.2017 01.07.2017
duties taxes & F&I
1 Line Supports (POLES)
1 1.01 RCC Pole - 9 Mtr Long, 145 Kg WL 200105 No 5941 5941 5904
2 1.02 RCC Pole - 9 Mtr Long, 150 Kg WL Sq Section 200106 No 7210 7210 7165
3 1.03 RCC Pole - 8 Mtr Long, 115 Kg WL 200103 No 4324 4351 4324
4 1.04 PCC Pole - 8 Mtr Long, 140 Kg WL 200003 No 2297 2495 2479
5 1.05 PSCC Pole - 8 Mtr Long, 200 Kg WL 200004 No 2814 2942 2923
6 1.06 PSCC Pole - 9 Mtr Long, 200 Kg WL 200006 No 3278 3401 3380
PSCC Pole - 9 Mtr Long, 160 Kg WL in Transverse Direction &
7 1.07 200007 No 3558 3558 3535
136 Kg WL in Longitudinal Direction
8 1.08 Pre - Stressed Tubular Spun Pole 11 Mtr Long - 500Kg WL 200120 No 15800 15800 15700
9 1.09 RCC Pole - 9.5 Mtr Long, 350 Kg WL for 33kV Lines 200107 No 7675 7675 7627
11Mtrs Long PSC pole of working Load 365 Kg for intermediate
10 1.10 200010 No 7924 7924 7874
poles only
11 1.11 9 Mtr PSCC Pole with working load of 300Kg 4578 4578 4549
12 1.12 Guy less poles New Item Will be intimated Will be intimated
Strut pole made of released MS Rail pole or Tubular pole along
13 1.13 200514 No 2310 2008 2008
with clamp fish plate, bolts & nuts
11Mtrs Long pole made of I Beam (MS) section size 200x100mm
14 1.14 200621 No 18009 15657 15657
25.9 Kg/mtr
11Mtrs Long pole made of I Beam (MS) section size 175x85mm
15 1.15 200610 No 12321 10712 10712
19.5 Kg/mtr
2 Cross Arms (MS & GI)
16 2.01 11kV Horizontal X Arms - Mild Steel (MS) 279020 No 281 238 245
17 2.02 11kV Horizontal X Arms - Galvanised Iron (GI) 280020 No 359 315 325
18 2.03 11kV Special 3 Pin X Arm - MS 279013 No 664 561 578
19 2.04 11kV Special 3 Pin X Arm - GI 280013 No 848 745 768
20 2.05 LT 4 Pin X Arms - MS 279014 No 218 185 191
21 2.06 LT 4 Pin X Arms - GI 280014 No 278 245 252
22 2.07 LT 2 Pin X Arms - MS 279012 No 100 84 87
23 2.08 LT 2 Pin X Arms - GI 280012 No 127 112 115
2 Pin Cross Arm with pole clamp, bolt & nuts & washers for RCC
24 2.09 - No 200 162 167
Pole - MS
2 Pin Cross Arm with pole clamp, bolt & nuts & washers for RCC
25 2.10 248 219 226
Pole - GI
2 Pin Cross Arm with pole clamp, bolt & nuts & washers for PSC
26 2.11 - No 194 157 162
Pole - MS
2 Pin Cross Arm with pole clamp, bolt & nuts & washers for PSC
27 2.12 240 212 218
Pole - GI
4 Pin Cross Arm with pole clamp, bolt & nuts & washers for RCC
28 2.13 - No 318 263 271
Pole - MS
4 Pin Cross Arm with pole clamp, bolt & nuts & washers for RCC
29 2.14 399 352 363
Pole - GI
4 Pin Cross Arm with pole clamp, bolt & nuts & washers for PSC
30 2.15 - No 312 258 266
Pole - MS
4 Pin Cross Arm with pole clamp, bolt & nuts & washers for PSC
31 2.16 391 345 356
Pole - GI
11 kV Horizontal Cross Arm with single top support, clamp, Bolt
32 2.17 - No 449 382 394
& Nuts with washers for RCC Poles - MS
11 kV Horizontal Cross Arm with single top support, clamp, Bolt
33 2.18 567 505 520
& Nuts with washers for RCC Poles - GI
11 kV Horizontal Cross Arm with single top support, clamp, Bolt
34 2.19 - No 443 377 389
& Nuts with washers for PSCC Poles - MS
11 kV Horizontal Cross Arm with single top support, clamp, Bolt
35 2.20 559 498 513
& Nuts with washers for PSCC Poles - GI
Special 3 Pin Cross Arm, clamp and Bolt & Nuts for RCC Poles -
36 2.21 - No 764 639 659
MS
Special 3 Pin Cross Arm, clamp and Bolt & Nuts for RCC Poles -
37 2.22 969 852 878
GI
38 2.23 LT ST Support 50x6mm Flat - MS 279091 No 50 43 44
39 2.24 LT ST Support 50x6mm Flat - GI 280091 No 64 56 58
40 2.25 HT ST Support 50x6mm Flat - MS 279092 No 68 59 61
41 2.26 HT ST Support 50x6mm Flat - GI 280092 No 87 76 78
42 2.27 Brace for LT 4pin X arm (600mm long) - MS 279082 No 215 187 193
43 2.28 Brace for LT 4pin X arm (600mm long) - GI 280082 No 269 234 241
44 2.29 Brace for 11 kV special 3pin X arm (900mm long) - MS 279083 No 299 260 268
45 2.30 Brace for 11 kV special 3pin X arm (900mm long) - GI 280083 No 374 325 335
46 2.31 LT Cross arms for vertical Configuration - MS 279017 No 720 626 645
47 2.32 LT Cross arms for vertical Configuration - GI 280017 No 901 784 808
48 2.33 EG Stirrups (MS) with GI wire lacing 279130 No 212 185 191
49 2.34 Spiral Earth Electrode 281683 No 238 207 213
3 SMC Line Materials
11KV Cross arm with HT top support (glass reinforced hot
50 3.01 279090 No 750 750 746
pressed SMC compound)
4 Anticlimbing Device
51 4.01 Spike type GI About 3.0 Kg in weight 278910 No 151 131 131
52 4.02 GI Barbed wire (12mtrs/Kg) 278911 Each 73 64 64
5 Clamps (MS & GI)
53 5.01 RCC Pole clamp - MS 279523 No 60 50 52
54 5.02 RCC Pole clamp - GI 280523 No 76 67 69
55 5.03 PCC Pole clamp - MS 279503 No 50 42 43
56 5.04 PCC Pole clamp - GI 280503 No 63 55 57
57 5.05 PSCC Pole clamp - MS 279510 No 54 45 46
58 5.06 PSCC Pole clamp - GI 280510 No 68 60 62
59 5.07 PCC Pole clamp type A for LT X arm - MS 279502 No 53 44 45
60 5.08 PCC Pole clamp type A for LT X arm - GI 280502 No 66 58 60
61 5.09 PCC Pole clamp type A for X arm upto 1M from pole top - MS 279522 No 53 44 45
62 5.10 PCC Pole clamp type A for X arm upto 1M from pole top - GI 280522 No 66 58 60
Clamps for fixing MV Lamp control box, fuse box/St light fixture
63 5.11 279550 No 61 53 55
on rail pole - MS
64 5.12 Guy clamp - MS 279650 No 59 50 52
65 5.13 Guy clamp - GI 280650 No 75 66 68
66 5.14 Turn buckle (GI) 279146 No 183 159 164
67 5.15 Anchor Rod using 12mm rounds/Guy Rod - MS 279140 No 191 162 167
68 5.16 Anchor Rod using 12mm rounds/Guy Rod - GI 280140 No 244 215 222
69 5.17 RCC pole type C clamp for GOS Operating Handle 279524 No 61 53 55
70 5.18 MS Fish Plate 279800 No 59 51 53
71 5.19 GI Fish Plate 280800 No 67 58 60
72 5.20 Strain Clamps, 3 Bolt type for 70/90 kN Disc Insulator 285076 No 546 468 482
6 Insulators
73 6.01 11kV Ceramic Pin Insulator (Shell only) 283005 No 49 47 47
74 6.02 11kV GI Pin for 11kV Ceramic Shell Insulators 283055 No 54 47 47
75 6.03 1.1kV Ceramic Pin Insulator (Shell only) 283003 No 15 15 15
76 6.04 1.1kV GI Pin FOR 11kV Cermaic shell Insulator 283053 No 26 23 23
11kV, 5KN Composite/Polymeric Pin Insulator(20mm dia FP
77 6.05 283007 No 169 165 164
Rod)
11kV, 5KN Composite/Polymeric Pin Insulator(24mm dia FP
78 6.06 New Item 195 194
Rod)
79 6.07 No.8 Strain Insulator 283158 No 14 14 14
80 6.08 No.15 Strain Insulator 283166 No 34 33 33
81 6.09 DISC Insulator 45kN 283040 No 300 290 288
82 6.10 DISC Insulator 70kN, Ball & Socket type 283017 No 506 490 487
83 6.11 DISC Insulator 90kN, Ball & Socket type 283018 No 506 490 487
84 6.12 DISC Insulator 120kN, Ball & Socket type 283021 No 506 490 487
85 6.13 11kV Solid Core Insulator 283315 No 157 152 151
86 6.14 11kV Post Insulator 283101 No 371 359 357
Silcon Rubber Composite Insulator/11kV 45kN Polymeric
87 6.15 283320 No 170 170 169
Insulator
88 6.16 11kV, 70kN Composite/Polymeric Insulator 283045 No 287 287 285
7 Accessories for composite insulator
89 7.01 Cross Arm Strap (MS) 279030 No 80 69 71
90 7.02 Strain Clamp up to Rabbit ACSR 285058 No 190 163 168
91 7.03 Strain Clamp for Coyote ACSR 285066 No 411 353 364
8 Conductor
92 8.01 Weasel ACSR 284105 Km 21900 20100 19387
93 8.02 Rabbit ACSR 284108 Km 36810 33676 32884
94 8.03 Coyote ACSR 284116 Km 93860 92708 91177
95 8.04 Lynx ACSR 284120 Km 139000 137290 135003
9 Guy Wire & GI Wire
96 9.01 7/10 SWG Guy Wire 281110 MT 64630 56267 56277
97 9.02 8 SWG GI Wire 281008 MT 62800 54674 54684
98 9.03 10 SWG GI Wire 281010 MT 66256 57683 57694
99 9.04 GI Barbed Wire 12 SWG 281205 MT 77972 67882 67895
10 PG Clamps
100 10.01 PG clamps for Lynx ACSR 285518 No 304 261 239
101 10.02 Coyote to Coyote 285515 No 276 267 245
102 10.03 Rabbit to Rabbit 285508 No 89 76 70
103 10.04 Weasel to Rabbit 285549 No 77 66 60
104 10.05 Weasel to Weasel 285509 No 60 52 48
105 10.06 Squirrel to Weasel 285548 No 56 48 44
11 PG Clamps Rabbit to Insulated Wire
106 11.01 95 Sqmm 285555 No 122 105 96
107 11.02 120 Sqmm 285557 No 238 204 187
108 11.03 150 Sqmm 285559 No 280 241 221
109 11.04 185 Sqmm 285562 No 308 264 242
110 11.05 240 Sqmm 285565 No 357 307 281
T - Clamps for Rabbit conductor with hot dipped galvanized
111 11.06 285600 Set 276 237 217
bolts, Nuts and Washers
T - Clamps for Coyote conductor with hot dipped galvanized
112 11.07 285605 Set 366 314 288
bolts, Nuts and Washers
T - Clamps for Lynx to Lynx with hot dipped galvanized bolts,
113 11.08 285610 Set 383 328 300
Nuts and Washers
114 11.09 Single Tension Clamp Suitable for Rabbit 285068 No 567 487 446
115 11.10 Single Tension Clamp Suitable for Coyote 285079 No 799 685 628
116 11.11 Pad Clamps for Rabbit ACSR 285723 No 439 376 344
117 11.12 Pad Clamps for Lynx ACSR 285726 No 606 520 476
118 11.13 Pad Clamps for Coyote ACSR 285724 No 544 467 428
119 11.14 C - Type wedge connector + 2 hole padle for Rabbit ACSR 285661 No 412 354 324
120 11.15 C - Type wedge connector + 2 hole padle for Coyote ACSR 285662 No 1712 1468 1345
121 11.16 C - Type wedge connector + 4 hole padle for Coyote ACSR 285663 No 1966 1686 1544
122 11.17 C - Type wedge connector + 2 hole padle for Lynx ACSR 285664 No 2600 2230 2043
123 11.18 C - Type wedge connector + 4 hole padle for Lynx ACSR 285665 No 2853 2447 2242
12 C - Type wedge connector
124 12.01 Rabbit to Rabbit ACSR 285670 No 142 122 112
125 12.02 Rabbit to Coyote ACSR 285671 No 740 635 582
126 12.03 Rabbit to Lynx ACSR 285673 No 740 635 582
127 12.04 Coyote to Coyote ACSR 285676 No 740 635 582
128 12.05 Rabbit to 240 Sqmm Lead Wire 285694 No 740 635 582
129 12.06 Coyote to 240 Sqmm Lead Wire 285695 No 740 635 582
130 12.07 Coyote to Lynx ACSR 285678 No 1305 1120 1026
131 12.08 Lynx to Lynx ACSR 285680 No 1305 1120 1026
186 20.02 LT Distribution Box for 100/250 kVA DTC with MCCB's (SMC) 301060 No 24715 24715 24559
195 22.06 LT Wiring kit for 25kVA Transformers (MESCOM Specification) 301156 Set Deleted
23 Lightning Aresters
196 23.01 LA 9kV, 5kA, Metal Oxide 303200 No 761 690 686
197 23.02 LA 9kV, 5kA, Polymeric Type 303205 No 1164 1147 1140
24 HG Fuse Unit
198 24.01 11kV Class, HG Fuse Unit with Solid Core Insulators 302122 Set/3 No 871 827 852
25 Double Pole TC Sets
199 25.01 For 25/63kVA Transformer - MS 279110 Set 8500 7389 7615
200 25.02 For 25/63kVA Transformer - GI 280110 Set 10780 9386 9673
201 25.03 For 25/63kVA Star Rated Transformer - MS 279111 Set 12250 10650 10976
202 25.04 For 25/63kVA Star Rated Transformer - GI 280111 Set 15545 13533 13947
203 25.05 For 100/300kVA Transformer - MS 279120 Set 14600 12693 13081
204 25.06 For 100/300kVA Transformer - GI 280120 Set 18562 16160 16654
Single Pole Mounted Transformer Kit for 250kVA
26
on 11 Mtr Spun Poles
Single H Frame with Transformer Seating and Seating angle
205 26.01 279127 Set 19534 16983 17502
support X arm for 11 mtr Spun Pole for 25kVA (OH Line) - MS
323 44.06 Fabrication & supply of structrual steel including painting etc., 312554 Set 7825 7825 7789
324 44.07 9.6kV, 200A long duration porcelien housed Surge arrestors 312555 Each 1569 1569 1562
340 46.07 Retrofitting of MEI make oil switch type OD with VCB 302470 No 171590
47 Conventional RMU Spares (VCB Type)
341 47.01 Bus Support Insulator with Stem 506505 No 1095 To be deleted To be deleted
CTs Trom Bone Type, 11kV Class, 200 - 100/5A, VA - 15, Class
342 47.02 506520 No 18755 To be deleted To be deleted
5P - 10
343 47.03 CTs resin cast, 11kV Class,400 - 200/5A, UA15, Class 5P - 10 506525 No 18755 To be deleted To be deleted
344 47.04 Spout Grid Insulator Assembly (Back) 506530 No 4247 To be deleted To be deleted
345 47.05 Spout Grid Insulator Assembly (Front) 506535 No 4247 To be deleted To be deleted
346 47.06 PT Insulator (Spout) 3 Nos 506540 No 448 To be deleted To be deleted
347 47.07 Shunt Trip Coil 506545 No 757 To be deleted To be deleted
348 47.08 Closing Coil 506550 No 757 To be deleted To be deleted
349 47.09 Plug Assembly for grid 800A, 6 Nos 506555 No 1579 To be deleted To be deleted
350 47.10 Para Plast Compound 506560 No 750 To be deleted To be deleted
351 47.11 PT Fuse(NT) 11kV/V3 Amps without Stem, VTF Type - 11 506565 No 2837 To be deleted To be deleted
352 47.12 Insulated Housing 506510 No 27386 To be deleted To be deleted
353 47.13 Switch Insulators Left/Right/Centre 506515 No 5963 To be deleted To be deleted
354 47.14 Vacuum Interruptor 20kA 506570 No 23958 To be deleted To be deleted
355 47.15 Flower Contact 506580 No 1065 To be deleted To be deleted
48 For Schneider make RMU
356 48.01 Tripping Coil 506445 No 9345 To be deleted To be deleted
357 48.02 VIP Relay 506481 No 51398 To be deleted To be deleted
358 48.03 Live Cable Indicator 440615 No 3894 To be deleted To be deleted
359 48.04 11KV Fault Passage Indicator for Overhead Line 302580 No 14810 14810 14810
377 53.02 11kV, AB Cable Straight thru' joint kit suitable for 95 Sqmm 284853 No 2963 deleted deleted
378 53.03 11kV, AB Cable Straight thru' joint kit suitable for 95 Sqmm set / 3 nos New Item 5650 5823
379 53.04 11kV, AB Cable Straight thru' joint kit suitable for 120 Sqmm set / 3 nos New Item 6000 6183
380 53.05 11kV ABC - T Jointing kit 95 - 120 Sqmm 284863 No 3757 deleted deleted
381 53.06 11kV ABC Termination kit 95 - 120 Sqmm 284873 No 1879 2100 2164
382 53.07 Surge Arester( for AB Cable) 303100 No 803 593 611
383 53.08 Ground Connection for Messenger Wire 284880 No 122 122 126
384 53.09 Anchor Sleeve for Messenger Wire 284885 No 23 Deleted deleted
385 53.1 Single Phase Distribution Box for 20 Connections(SMC) 284820 No 1806 2065 2128
Single Phase Distribution Box for 10
386 53.11 284818 No 2065 1950 2010
Connections(SMC/polycarbonate)
Three Phase Distribution Box for 5
387 53.12 284815 No 2065 2065 2128
Connections(SMC/Polycarbonate)
388 53.13 Three Phase Distribution Box for 6 Connections(SMC) 1987 2065 2128
Piercing Connector Suitable for 16 Sqmm - 95 Sqmm AB Cable -
389 53.14 284822 No 228 228 235
Service Connections
Piercing Connector Suitable for 16 Sqmm - 95 Sqmm AB Cable -
390 53.15 284223 No 160 160 165
Street Light Connections
Piercing Connector Suitable for 25 Sqmm - 95 Sqmm AB Cable -
391 53.16 284855 No 267 267 275
Main to Main Connections
Piercing Connector Suitable for 50 Sqmm - 150 Sqmm AB Cable -
392 53.17 284865 No 267 300 309
Main to Main Connections
393 53.18 Universal Hook and Bolts & Nuts 284284 No 305 305 314
Dead End Clamp/Anchor Clamp Assembly 25 to 95 Sqmm Bare
394 53.19 284825 No 152 131 135
Messenger(Exclusive of pole clamp and eye hook)
Dead End Clamp/Anchor Clamp Assembly 16 to 70 Sqmm Bare
395 53.20 New Item 200 206
Messenger(Exclusive of pole clamp and eye hook)
397 53.22 Suspension Clamp Assembly 25 to 95 Sqmm Bare Messenger 284826 No 305 deleted deleted
407 53.32 Straight Joints Suitable for 95 Sqmm, LT ABC - MJPT Type 284832 No 310 310 319
408 53.33 Straight Joints Suitable for 70 Sqmm, LT ABC - MJPT Type 284830 No/ 1 core 289 289 298
409 53.34 Straight Joints Suitable for50 Sqmm, LT ABC - MJPT Type 284831 No 271 271 279
410 53.35 Straight Joints Suitable for 25 Sqmm, LT ABC - MJPT Type No New Item 250 258
411 53.36 Straight Joints Suitable for 16 Sqmm, LT, ABC - MJPT Type 284840 No 181 181 187
508 67.03 LT Electronic Tri - Vector Meter 5A, Class-0.5/1.0 accuracy 357511 No Deleted Deleted Deleted
509 67.04 LT Electronic Tri - Vector Meter 5A, Class-0.5 accuracy 357510 No 3000 2250 2061
510 67.05 HT Electronic Tri - Vector Meter 5A, Class-0.5 accuracy 357512 No 3463 2600 2382
HT Electronic Tri - Vector Meter 5A, Class-0.2 accuracy with
511 67.06 357500 No 15750 11658 10679
ABT features
512 67.07 Electronic Meter, 5-10A/5-20A, SPh Class-1 Accuracy 357003 No Deleted Deleted Deleted
LT Single phase 5-30A, DLMS complaint static energy meter,
513 67.08 357006 No 905 733 671
class-1.0 Accuracy
514 67.09 Electronic Meter, 2.5-10A/5-20A, 3 Ph Class-1 Accuracy 357205 No Deleted Deleted Deleted
516 67.11 Electronic Meter, 10-40A, 3 Ph Class-1 Accuracy 357201 No Deleted Deleted Deleted
LT Three phase, 4wire, CT Operated DLMS complaint ETV meter-
517 67.12 357519 No 3000 2450 2244
/5, class 05s Accuracy
Electronic Meter, 5-20/30A, 3 Ph 4 wire Class - 1 Accuracy
518 67.13 357200 No Deleted Deleted Deleted
(whole current)
Electronic Meter, 10-40/60A, 3 Ph Class-1, 4 wire Accuracy
519 67.14 357206 No Deleted Deleted Deleted
(whole current)
Electromechanical Energy Meter - 3 Ph, 5-20A, Class-2
520 67.15 357122 No Deleted Deleted Deleted
Accuracy, for IP Sets
LT, S.Ph, 5-30 A Static Energy Meter of Accuracy Class in retail
521 67.16 357015 No Deleted Deleted Deleted
out lets of BESCOM
522 67.17 Pre - paid Energy meter single phase, 5-30A 357580 No 10733 10733 9832
523 67.18 Pre - paid Energy meter three phase, 5-30A 357585 No 13532 13532 12396
3 phase 4 wire static meter (CT, PT operated) 3 x 63.5 V, 5 Amps
524 67.19 357514 No 14745 14745 13507
or 1 Amps class 0.2s with Rs - 485 & ABT features
574 71.20 CT-11KV, 5/1A to 100/1A, Burden:2.5VA Accuracy Class 0.2 No New Item 6960 6376
802 86.02 Programmable Logic Controllers with communication ports 358098 Set 19339 19339 17716
815 87.01 With 100 kVA Oil Cooled Transformer 276530 No 1132904
816 87.02 With 250 kVA Oil Cooled Transformer 276540 No 1491923
817 87.03 With 500 kVA Oil Cooled Transformer 276550 No 2009325
818 87.04 With 750 kVA Oil Cooled Transformer 276575 No 2415622
819 87.05 With 990 kVA Oil Cooled Transformer 276590 No 2821919
Will be intimated Will be intimated
820 87.06 With 100 kVA Dry Type Transformer 276531 No 1182768
821 87.07 With 250 kVA Dry Type Transformer 276541 No 1611596
822 87.08 With 500 kVA Dry Type Transformer 276560 No 2212473
823 87.09 With 750 kVA Dry Type Transformer 276585 No 2711112
824 87.10 With 990 kVA Dry Type Transformer 276599 No 3191280
87.11 Breakup prices
Copper wound Oil Cooled Distribution Transformer
825 87.12 500 kVA 321450 No 805743
826 87.13 750 kVA 321475 No 997537
827 87.14 990 kVA 321490 No 1331175 Will be intimated Will be intimated
828 87.15 LT ACB 2000A 310520 No 115716
829 87.16 MCCB 400A 358097 No 14100
85 SCRAP MATERIALS
Note: The rates are indicative and the respective zones are
authorized to fix the floor price suitabaly as approved in the
Common SR 2012-13 meeting held on 09.11.2012 and
confirmed vide proceedings CEE/T&P/KPTCL - 6998 - 7013
Dt: 15.11.2012
830 85.01 Copper Wire 791210 Kg 512 518 574
Released Copper winding released from failed distribution
831 85.02 731211 Kg 192 192 213
transformers
832 85.03 Copper Conductor 791200 Kg 512 518 574
833 85.04 Copper Ingots 791205 Kg 358 358 396
834 85.05 Copper Cable with Leads 791207 Kg 248 248 275
835 85.06 Aluminium 791010 Kg 124 124 137
836 85.07 Aluminium wire in pieces 791100 Kg 85 88 97
837 85.08 ACSR Conductor in Rings/Coils New Item 100 111
Released Aluminium winding released from failed distribution
838 85.09 791175 Kg 100 130 144
transformers
839 85.10 Scrap HT/LT Aluminium Winding D New Item 161 178
840 85.11 ACSR Conductor 791101 Kg 89 100 111
841 85.12 Alumininium UG cable 791531 Kg 103 103 114
842 85.13 Scrap Al Released From UG Cable 791530 Kg 88 88 97
Iron Items 0
843 85.14 a) SM Rail Pole, I beam 790100 Kg 20 32 35
844 85.15 b) Ladder Pole, Tower Parts, Tubular Poles 790101 Kg 20 18 20
845 85.16 c) Cross arms,Clamps etc 790104 Kg 20 20 22
846 85.17 d) Released steel from RCC Poles (Skeleton rods) 790103 Kg 20 20 22
847 85.18 e) Barbed/Ground wire/Zinc sheet etc 790102 Kg 20 20 22
848 85.19 Transformer Empty tanks of different capacity 790300 No Deleted deleted deleted
849 85.20 Transformer Empty tanks of different capacity 790300 Kg 18 17 19
850 85.21 Scrap GOS with Insulators 790401 Kg 25 25 28
851 85.22 Broken Steel Furniture 790402 Kg 26 26 29
852 85.23 Brass 791300 Kg 176 176 195
853 85.24 Baliga Poles 793510 Rmtr 72 72 80
854 85.25 Scrap Wooden Furniture 793501 Kg 16 16 18
855 85.26 Empty Barrel of 210 Litres Capacity - Good 442120 No 440 455 504
856 85.27 Empty Barrel of 210 Litres Capacity - Bad 795030 No 292 284 315
857 85.28 Lead 791400 Kg 80 80 89
858 85.29 HT Metering Cubicle, Distribution Boxes, Feeder Piller Boxes etc 795240 Kg 20 18 20
SL Labour
No Materials rate Materials rate charges
Particulars Unit
in Rs. in Rs. With GST (Casual) in
Rs
1 2 3 4 5 6
I RCC Poles
a) 9.5 M 350kg WL Nos 7,675.00 7,627.00 1,373.00
b) 9M 145kg WL Nos 5,941.00 5,904.00 1,060.00
c) 9M 150kg WL Square section Nos 7,210.00 7,165.00 1,060.00
d) 8M 115kg WL Nos 4,351.00 4,324.00 848.00
II PCC Poles
8M PCC Poles 140kg WL Nos 2,495.00 2,479.00 848.00
III PSC Poles
a) 11M 365kg WL Nos 7,924.00 7,874.00 1,552.00
b) 9M 200kg WL Nos 3,401.00 3,380.00 1,060.00
d) 8M 200kg WL Nos 2,942.00 2,923.00 848.00
IV Pre-Stressed Tubular Spun Pole
11M Long Nos 15,800.00 15,700.00 2,353.00
V PSCC Poles
a) 9M PSCC pole WL 300Kg Nos 4,578.00 4,549.00 1,060.00
b) 9M PSCC pole 160Kg WL in
Transverse direction and 136Kg WL Nos 3,558.00 3,535.00 1,060.00
in Longitudinal directional
VI Double Pole Structure complete including 5 KG, 8 SWG GI Wire for Structure
Grounding
a) 9M RCC Poles Set 15,910.00 15,951.40 3,252.00
b) 8M RCC Poles Set 12,730.00 12,791.40 3,104.00
c) 9M PSCC Poles with 300Kg WL Set 13,184.00 13,241.40 3,252.00
VII Three Pole structure complete including 5 KG, 8 SWG GI Wire for Structure
Grounding
a) 9M RCC Poles Set 27,446.00 21,717.40 6,271.00
b) 8M RCC Poles Set 22,676.00 18,557.40 6,049.00
c) 9M PSCC Poles with 300Kg WL Set 23,357.00 19,007.40 6,271.00
VIII
Transformer Structure complete with cross arms braces, clamps, bolt and washers
XXVII Set/
EG Stirrup With GI Lacing 370.00 382.00 99.00
2 Nos
XXVIII Spiral Earth Electrode Set 207.00 213.00 55.00
Included in
b) Rod Type Set 2,000.00 1,832.00
Material cost
As per
Drawing No.
a) Guy concreting with Boulders,
BESCOM/G 158.00 158.00
Mud & Sand
M/CP/7/dt
24.10.07
Flat Armoured
a) 3x95 Sqmm km 548,860.00 591,925.00 35,797.00
b) 3x240 Sqmm km 1,038,890.00 1,120,404.00 37,786.00
c) 3x400 Sqmm km 1,565,000.00 1,687,794.00 39,774.00
Round Armoured
a) 3x95 Sqmm km 675,110.00 728,081.00 35,797.00
b) 3x240 Sqmm km 1,279,950.00 1,380,378.00 37,786.00
c) 3x400 Sqmm km 1,956,000.00 2,109,472.00 39,774.00
XXXIX Fixing 3-phase LT Capacitor housed in a enclosure with necessary Fuses, wiring,
1 RCC Pole - 9 Mtrs Long, 145 kg WL Nos 1 5904 5904 1060 1060
2 PSC Pole - 9 Mtrs Long, 200 kg WL Nos 23 3380 77740 1060 24380
5 DP Structure with 9 Mtrs RCC Poles Set 1 15951 15951 3252 3252
6 11 KV, 5KN Polymeric Pin Insulator (24mm Dia FRP Rod) Nos 72 194 13968 0 0
Set of 2
12 EG Stirrups with GI wire lacing 24 382 9168 99 2376
Nos
13 Concreting materials for guy sets without cement Nos 6 158 948 0 0
16 Labour charges
a) Casual 45973
b) Regular 9195
Note: Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 2
Running Single Circuit 11 kV, 3-Phase Power Line on 9.0 Mtr Supports with an Average Span of 50 Mtrs Using Rabbit ACSR
Conductor
1 RCC Pole - 9 Mtrs Long, 145 kg WL Nos 1 5904 5904 1060 1060
2 PSC Pole - 9 Mtrs Long, 200 kg WL Nos 18 3380 60840 1060 19080
5 DP Structure with 9 Mtrs RCC Poles Set 1 15951 15951 3252 3252
6 11 KV, 5KN Polymeric Pin Insulator (24mm Dia FRP Rod) Nos 57 194 11058 0 0
Set of 2
12 EG Stirrups with GI wire lacing 19 382 7258 99 1881
Nos
13 Concreting materials for guy sets without cement Nos 6 158 948 0 0
16 Labour charges
a) Casual 39283
b) Regular 7857
Note: Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 3
Running Single Circuit 11 kV , 3-Phase Power Line on 8.0 Mtr Supports with an Average Span of 50 Mtrs Using RABBIT ACSR
Conductor
1 RCC Pole - 8.0M Long, 145 kg WL Nos 1 4324 4324 848 848
2 PSC Pole - 8.0M Long, 200 kg WL Nos 18 2479 44622 848 15264
5 DP Structure with 8 Mtrs RCC Poles Set 1 12791 12791 3104 3104
6 11 KV, 5KN Polymeric Pin Insulator (24mm Dia FRP Rod) Nos 57 194 11058 0 0
Set of 2
12 EG Stirrups with GI wire lacing 19 382 7258 99 1881
Nos
13 Concreting materials for guy sets without cement Nos 6 158 948 0 0
16 Labour charges
a) Casual 35107
b) Regular 7021
Note: Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 4
Running Single Circuit 11 kV, 3-Phase Power Line on 9.0 Mtr Supports with an Average Span of 40 Mtrs Using COYOTE ACSR
conductor
1 RCC Pole - 9 Mtrs Long, 145 kg WL Nos 1 5904 5904 1060 1060
2 PSC Pole - 9 Mtrs Long, 200 kg WL Nos 22 3380 74360 1060 23320
5 DP Structure with 9 Mtrs RCC Poles Sets 2 15951 31902 3252 6504
6 11 KV, 5KN Polymeric Pin Insulator (24mm Dia FRP Rod) Nos 69 194 13386 0 0
8 Strain Clamp 3 bolt type for Disc Insulator Nos 12 482 5784 0 0
Set of 2
13 EG Stirrups with GI wire lacing 23 382 8786 99 2277
Nos
14 Concreting materials for guy sets without cement Nos 6 158 948 0 0
17 Labour charges
a) Casual 54072
b) Regular 10814
Note: Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 5
Running Single Circuit 11 kV 3 Phase Power Line and 3 Phase - 4 Wire Secondary Line on 9 Mtr Supports with an Average Span of
50 Mtrs using RABBIT Conductor for HT and WEASEL for LT Lines
1 RCC Pole - 9 Mtrs Long, 145 kg WL Nos 1 5904 5904 1060 1060
2 PSC Pole - 9 Mtrs Long, 200 kg WL Nos 18 3380 60840 1060 19080
7 DP Structure with 9 mtr RCC Poles Set 1 15951 15951 3252 3252
8 11 KV, 5KN Polymeric Pin Insulator (24mm Dia FRP Rod) Nos 57 194 11058 0 0
13 Rabbit ACSR for HT Lines Kms 3.045 32884 100132 2608 7941
14 Weasel ACSR for LT lines Kms 4.06 19387 78711 1913 7767
b) 4 Pin cross arms with clamps,bolts, nuts and washers. Sets 20 273 5460 0 0
21 Labour charges
a) casual 59809
b) Regular 11962
Note: Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 6
Running Single Circuit 11 kV, 3-Phase Power Line & 3 Phase 4 Wire Secondary Line on 9.0 Mtr Supports with an Average Span of 40
Mtrs Using RABBIT ACSR conductor for HT & LT Lines
1 RCC Pole - 9 Mtrs Long, 145 kg WL Nos 1 5904 5904 1060 1060
2 PSC Pole - 9 Mtrs Long, 200 kg WL No's 23 3380 77740 1060 24380
7 DP Structure with 9 mtr RCC Poles Set 1 15951 15951 3252 3252
8 11 KV, 5KN Polymeric Pin Insulator (24mm Dia FRP Rod) Nos 72 194 13968 0 0
b) 4 Pin cross arms with clamps,bolts, nuts and washers. Sets 25 273 6825 0 0
17 Concreting materials for guy sets without cement Nos 8 158 1264 0 0
20 Labour charges
a) Casual 72369
b) Regular 14474
Note: Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 7
Running LT, 3-Phase 4 Wire Power Line on 8.0 Mtr Supports Using WEASEL ACSR Conductor with an
Average Span of 60 Mtrs (IP Installations)
1 RCC Pole - 8 Mtrs Long, 145 kg WL Nos 1 4324 4324 848 848
2 PSC Pole - 8 Mtrs Long, 200 kg WL Nos 17 2479 42143 848 14416
10 Concreting materials for guy sets without cement Nos 8 158 1264 0 0
12 Labour charges
a) Casual 29031
b) Regular 5806
Note: Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 8
Running LT , 3-Phase 4 Wire Power Line on 8.0 Mtr Supports Using RABBIT ACSR Conductor with an
Average Span of 40 Mtrs
1 RCC Pole - 8 Mtrs Long, 145 kg WL Nos 1 4324 4324 848 848
2 PSC Pole - 8 Mtrs Long, 200 kg WL Nos 24 2479 59496 848 20352
10 Concreting materials for guy sets without cement Nos 8 158 1264 0 0
12 Labour charges
a) Casual 39020
b) Regular 7804
Note: Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 9
Running LT, 3-Phase 4 Wire Power Line on 9.0 Mtr Supports Using RABBIT ACSR Conductor with an
Average Span of 40 Mtrs
1 RCC Pole - 9 Mtrs Long, 145 kg WL Nos 1 5904 5904 1060 1060
2 PSC Pole - 9 Mtrs Long, 200 kg WL Nos 24 3380 81120 1060 25440
10 Concreting materials for guy sets without cement Nos 8 158 1264 0 0
12 Labour charges
a) Casual 44320
b) Regular 8864
Note: Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 10
Running LT, 3-Phase 5 Wire for Power Line on 9.0 Mtr Supports Using RABBIT ACSR Conductor for Phase and Neutral, and
WEASEL Conductor or Street Light with an Average Span of 40 Mtrs (For Cities, Towns and Residential Layouts)
13 Concreting Materials for guy sets (without Cement) No's 8 158 1264 0 0
16 PVC Insulated wire 25 Sqmm Single Core Multi stranded Mtrs 25 32 800 0 0
18 Labour charges
a) Casual 50319
b) Regular 10064
Note: Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 11
Running LT, 3 Phase 5 Wire for Power Line on 8.0 Mtr Supports Using RABBIT ACSR Conductor for Phase and Neutral, and WEASEL
Conductor for Street Light with an Average Span of 50 mtrs
13 Concreting Materials for guy sets (Without Cement) Nos 8 158 1264 0 0
16 PVC Insulated wire 25 Sqmm Single Core Multi Stranded Mtrs 20 32 640 0 0
18 Labour charges
a) Casual 39412
b) Regular 7882
Note: Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 12
Running LT, Single Phase 3 Wire Power Line on 8.0 Mtr Supports with an Average Span of 40 Mtrs
Using WEASEL ACSR Conductor
12 Concreting Materials for guy sets (without cement) Nos 8 158 1264 0 0
15 PVC Insulated wire 25 Sqmm Single Core Multi Stranded Mtrs 25 32 800 0 0
17 Labour charges
a) Casual 37702
b) Regular 7540
Note: Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 13
Running LT, 3-Phase 5 Wire Power Line with Continuous Earth Wire on 9.0 Mtr Supports Using RABBIT ACSR for Phase and Neutral,
and WEASEL Conductor for Street Light and 8 SWG GI Wire for Continuous Earth Wire with an Average Span of 40 Mtrs in Vertical
Configuration
1.015
9 No.8 SWG GI wire for continuous earth wire Kms 54.684 5631 1913 1942
(103 kgs)
12 Concreting Materials for guy sets (Without Cement) Nos 8 158 1264 0 0
15 PVC Insulated wire 25 Sqmm Single Core Multi Stranded Mtrs 25 32 800 0 0
17 Labour charges
a) Casual 56395
b) Regular 11279
Note: Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 14
Running Single Circuit 11 kV, 3-phase Power Line on 9.0 Mtr Supports Using RABBIT ACSR Conductor With an Average Span of 40
Mtrs in Vertical Configuration in Congested Areas
3 DP Structure using 9 Mtrs RCC poles Set 1 15951 15951 3252 3252
5 11 KV, 5KN Polymeric Pin Insulator (24mm Dia FRP Rod) Nos 69 194 13386 0 0
11 Concreting Materials for guy sets (Without Cement) Nos 9 158 1422 0 0
13 Labour charges
a) Casual 51642
b) Regular 10328
Note: Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET -15
Providing 2 Pole Structrue at the Tapping Point Using RCC Poles
SL.
Paritculars Unit Qty Material cost Labour Cost
No
Total Part A
Labour Charges
a) Casual 5340
b) Regular 1068
Labour Charges
a) Casual 5488
b) Regular 1098
Note: Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET -16
SL.
Paritculars Unit Qty Material cost Labour Cost
No
3 Guy Set With No.15 Strain Insulator Complete Sets 3 752 2256 354 1062
5 11 KV, 5KN Polymeric Pin Insulator (24mm Dia FRP Rod) Nos 3 194 582 0 0
10 Labour Charges
a) Casual 7671
b) Regular 1534
Note: Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET -17
Estimate for Providing Metering to IP Set Installations Using SMC Box
2 SMC Meter Housing box with 6 mm hylam sheet Nos 1 2100 2100
6 3 Nos Porcelain Cutouts 60A with Wooden Plank Set 1 432 432
Total 6941
COST DATA SHEET - 18
For laying of 1 Km Length of 11kV, 3 Core 95 Sqmm XLPE UG Cable
Using Horizontal Drilling
SL. Material cost
Particulars Unit Qty
No Rate Amt
Material Cost
1 11kV Class 3x95 Sqmm XLPE UG Cable (Flat Armoured) Km 1 591925 591925
5 RCC Hume Pipe, 2000 mm Long, 150 mm Dia Nos 3 300 900
9 Labour charges
a) Casual 977303
b) Regular 195461
1 11kV Class 3x95 Sqmm XLPE UG Cable (Flat Armoured) Km 1 591925 591925
7 RCC Hume Pipe, 2000 mm Long, 150 mm Dia Nos 30 300 9000
11 Labour charges
NOTE
While preparing estimates for turnkey / total tunkey projects please refer to Sl. No. ......... of General
1)
Guidelines vide a to .... in Page No. ...........
When multiples cables have to be laid in the common trench the following excavation is to be followed: a)
2) 0.75 Mtrs x 1 Mtrs for 2 cables. b) 1 Mtr x 1 Mtr for 3 cables. c) 1.25 Mtr x 1 Mtr for 4 nos. of cables and
so on (As per Ltr No. BESCOM/BC-14/F-45
Where cables are laid using trenchless technology, there may be a necessity to lay the cable in open
3) trench excavation. Hence provision shall be made for both in the estimate and the bills shall be paid as
per actual inventory taken.
COST DATA SHEET - 20
For Laying of 1 Km Length of 11kV, 3 Core, 240 Sqmm XLPE UG Cable
Using Horizontal Drilling
SL. Material cost
Particulars Unit Qty
No Rate Amt
Material Cost
5 RCC Hume Pipe, 2000 mm Long, 150 mm Dia Nos 3 300 900
9 Labour charges
6 RCC Hume pipe, 2000 mm Long, 150 mm Dia Nos 30 300 9000
10 Labour charges
a) Cable trench excavation, 1000x0.6x1=600, Ordinary
Cmt 600 205 123000
soil
b) Laying of cable in trench Km 1 37786 37786
a) Casual 209598
b) Regular 41920
NOTE
While preparing estimates for turnkey / total tunkey projects please refer to Sl. No. ......... of General
1)
Guidelines vide a to .... in Page No. ...........
When multiples cables have to be laid in the common trench the following excavation is to be followed: a)
2) 0.75 Mtrs x 1 Mtrs for 2 cables. b) 1 Mtr x 1 Mtr for 3 cables. c) 1.25 Mtr x 1 Mtr for 4 nos. of cables and
so on (As per Ltr No. BESCOM/BC-14/F-45
Where cables are laid using trenchless technology, there may be a necessity to lay the cable in open
3) trench excavation. Hence provisionshall be made for both in the estimate and the bills shall be paid as
per actual inventory taken.
COST DATA SHEET - 22
For laying of 1 Km Length of 11kV, 3 Core, 400 Sqmm XLPE UG Cable
Using Horizontal Drilling
SL. Material cost
Particulars Unit Qty
No Rate Amt
Material Cost
6 RCC Hume Pipe, 2000 mm Long, 150 mm Dia Nos 3 300 900
a) Casual 977502
b) Regular 195500
When multiples cables have to be laid in the common trench the following excavation is to be followed: a)
2) 0.75 Mtrs x 1 Mtrs for 2 cables. b) 1 Mtr x 1 Mtr for 3 cables. c) 1.25 Mtr x 1 Mtr for 4 nos. of cables and
so on (As per Ltr No. BESCOM/BC-14/F-45
Where cables are laid using trenchless technology, there may be a necessity to lay the cable in open
3)
trench excavation. Hence provisionshall be made for both in the estimate and the bills shall be paid as
per actual inventory taken.
COST DATA SHEET - 23
For laying of 1 Km Length of 11kV, 3 Core, 400 Sqmm XLPE UG Cable
Using Conventional Laying with Excavation in Soil
Material cost
SL.
Particulars Unit Qty
No
Rate Amt
11kV Class 3x400 Sqmm XLPE UG Cable (Flat
1 Km 1 1687794 1687794
Armoured)
11kV Class 3x400 Sqmm XLPE UG Cable (Round
2 Km 1 2109472 2109472
Armoured)
Straight Through Jointing Kits HS Type suitable for
3 Nos 3 8296 24888
3x400 Sqmm Cable
Cable Termination Kit Outdoor HS Type Suitable for
4 Per Kit 1 4060 4060
3x400 Sqmm Cable
Cable Termination Kit Indoor HS Type Suitable for 3x400
5 Per Kit 1 3648 3648
Sqmm Cable
8 RCC Hume Pipe, 2000mm Long, 150mm Dia Nos 30 300 9000
10 Labour charges
a) Cable trench excavation, 1000x0.6x1=600, Ordinary
Cmt 600 205 123000
soil
b) Laying of cable in trench Km 1 39774 39774
a) Casual 211586
b) Regular 42317
When multiples cables have to be laid in the common trench the following excavation is to be followed: a)
2) 0.75 Mtrs x 1 Mtrs for 2 cables. b) 1 Mtr x 1 Mtr for 3 cables. c) 1.25 Mtr x 1 Mtr for 4 nos. of cables and
so on (As per Ltr No. BESCOM/BC-14/F-45
Where cables are laid using trenchless technology, there may be a necessity to lay the cable in open
3) trench excavation. Hence provisionshall be made for both in the estimate and the bills shall be paid as
per actual inventory taken.
COST DATA SHEET - 50
Running Single Circuit 11kV, 3 Phase Power Line On 9.0 Mtr Supports With An Average Span Of 40 Mtrs Using Rabbit ACSR
Conductor and PSCC poles of 300 Kg WL for dead ends and DP structure
1 PSCC Pole - 9 Mtrs Long, 300 kg WL Nos 1 4549 4549 1060 1060
2 PSC Pole - 9 Mtrs Long, 200 kg WL Nos 23 3380 77740 1060 24380
5 DP Structure with 9 Mtrs PSCC Poles of 300Kg WL Set 1 13241 13241 3252 3252
6 11 KV, 5KN Polymeric Pin Insulator (24mm Dia FRP Rod) Nos 72 194 13968 0 0
Set of 2
12 EG Stirrups with GI wire lacing 24 382 9168 99 2376
Nos
13 Concreting materials for guy sets without cement Nos 6 158 948 0 0
16 Labour charges
a) Casual 45973
b) Regular 9195
Note: Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 51
Running Single Circuit 11 kV, 3-Phase Power Line on 9.0 Mtr Supports with an Average Span of 50 Mtrs Using Rabbit ACSR
Conductor and PSCC poles of 300 Kg WL for dead ends and DP structure
1 PSCC Pole - 9 Mtrs Long, 300 kg WL Nos 1 4549 4549 1060 1060
2 PSC Pole - 9 Mtrs Long, 200 kg WL Nos 18 3380 60840 1060 19080
5 DP Structure with 9 Mtrs PSCC Poles of 300Kg WL Set 1 13241 13241 3252 3252
6 11 KV, 5KN Polymeric Pin Insulator (24mm Dia FRP Rod) Nos 57 194 11058 0 0
Set of 2
12 EG Stirrups with GI wire lacing 19 382 7258 99 1881
Nos
13 Concreting materials for guy sets without cement Nos 6 158 948 0 0
16 Labour charges
a) Casual 39283
b) Regular 7857
Note Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 52
Running Single Circuit 11 kV, 3-Phase Power Line on 9.0 Mtr Supports with an Average Span of 40 Mtrs Using COYOTE ACSR
conductor and PSCC poles of 300 Kg WL for dead ends and DP structure
1 PSCC Pole - 9 Mtrs Long, 300 kg WL Nos 1 4549 4549 1060 1060
2 PSC Pole - 9 Mtrs Long, 200 kg WL Nos 22 3380 74360 1060 23320
5 DP Structure with 9 Mtrs PSCC Poles of 300Kg WL Sets 2 13241 26482 3252 6504
6 11 KV, 5KN Polymeric Pin Insulator (24mm Dia FRP Rod) Nos 69 194 13386 0 0
8 Strain Clamp 3 bolt type for Disc Insulator Nos 12 482 5784 0 0
Set of 2
13 EG Stirrups with GI wire lacing 23 382 8786 99 2277
Nos
14 Concreting materials for guy sets without cement Nos 6 158 948 0 0
17 Labour charges
a) Casual 54072
b) Regular 10814
Note: 1) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 53
Running Single Circuit 11 kV 3 Phase Power Line and 3 Phase - 4 Wire Secondary Line on 9 Mtr Supports with an Average Span of
50 Mtrs using RABBIT Conductor for HT and WEASEL for LT Lines and using PSCC poles of 300 Kg WL for dead ends and DP
structure
1 PSCC Pole - 9 Mtrs Long, 300 kg WL Nos 1 4549 4549 1060 1060
2 PSC Pole - 9 Mtrs Long, 200 kg WL Nos 18 3380 60840 1060 19080
7 DP Structure with 9 Mtrs PSCC Poles of 300Kg WL Set 1 13241 13241 3252 3252
8 11 KV, 5KN Polymeric Pin Insulator (24mm Dia FRP Rod) Nos 57 194 11058 0 0
13 Rabbit ACSR for HT Lines Kms 3.045 32884 100132 2608 7941
14 Weasel ACSR for LT lines Kms 4.06 19387 78711 1913 7767
b) 4 Pin cross arms with clamps,bolts, nuts and washers. Sets 20 273 5460 0 0
21 Labour charges
a) casual 59809
b) Regular * 11962
Note: 1) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 54
Running Single Circuit 11 kV, 3-Phase Power Line & 3 Phase 4 Wire Secondary Line on 9.0 Mtr Supports with an Average Span of 40
Mtrs Using RABBIT ACSR conductor for HT & LT Lines and using PSCC poles of 300 Kg WL for dead ends and DP structure
1 PSCC Pole - 9 Mtrs Long, 300 kg WL Nos 1 4549 4549 1060 1060
2 PSC Pole - 9 Mtrs Long, 200 kg WL No's 23 3380 77740 1060 24380
7 DP Structure with 9 Mtrs PSCC Poles of 300Kg WL Set 1 13241 13241 3252 3252
8 11 KV, 5KN Polymeric Pin Insulator (24mm Dia FRP Rod) Nos 72 194 13968 0 0
b) 4 Pin cross arms with clamps,bolts, nuts and washers. Sets 25 273 6825 0 0
17 Concreting materials for guy sets without cement Nos 8 158 1264 0 0
20 Labour charges
a) Casual 72369
b) Regular 14474
Note: 1) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 55
Running LT, 3-Phase 4 Wire Power Line on 9.0 Mtr Supports Using RABBIT ACSR Conductor with an
Average Span of 40 Mtrs and using PSCC poles of 300 Kg WL for dead ends and DP structure
1 PSCC Pole - 9 Mtrs Long, 300 kg WL Nos 1 4549 4549 1060 1060
2 PSC Pole - 9 Mtrs Long, 200 kg WL Nos 24 3380 81120 1060 25440
10 Concreting materials for guy sets without cement Nos 8 158 1264 0 0
12 Labour charges
a) Casual 44320
b) Regular 8864
Note: 1) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 56
Running LT, 3-Phase 5 Wire for Power Line on 9.0 Mtr Supports Using RABBIT ACSR Conductor for Phase and Neutral, and
WEASEL Conductor or Street Light with an Average Span of 40 Mtrs and using PSCC poles of 300 Kg WL for dead ends and
Anchor Points (For Cities, Towns and Residential Layouts)
13 Concreting Materials for guy sets (without Cement) No's 8 158 1264 0 0
16 PVC Insulated wire 25 Sqmm Single Core Multi stranded Mtrs 25 32 800 0 0
18 Labour charges
a) Casual 50319
b) Regular 10064
Note:
1) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 57
Running LT, 3-Phase 5 Wire Power Line with Continuous Earth Wire on 9.0 Mtr Supports Using RABBIT ACSR for Phase and
Neutral, and WEASEL Conductor for Street Light and 8 SWG GI Wire for Continuous Earth Wire with an Average Span of 40 Mtrs
in Vertical Configuration and using PSCC poles of 300 Kg WL for dead ends and Anchor Points
1.015
9 No.8 SWG GI wire for continuous earth wire Kms 54.684 5631 1913 1942
(103 kgs)
12 Concreting Materials for guy sets (Without Cement) Nos 8 158 1264 0 0
15 PVC Insulated wire 25 Sqmm Single Core Multi Stranded Mtrs 25 32 800 0 0
17 Labour charges
a) Casual 56395
b) Regular 11279
Note:
1) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 58
Running Single Circuit 11 kV, 3-phase Power Line on 9.0 Mtr Supports Using RABBIT ACSR Conductorand using PSCC poles of
300 Kg WL for dead ends and Anchor Points, With an Average Span of 40 Mtrs in Vertical Configuration in Congested Areas
3 DP Structure with 9 Mtrs PSCC Poles of 300Kg WL Set 1 13241 13241 3252 3252
5 11 KV, 5KN Polymeric Pin Insulator (24mm Dia FRP Rod) Nos 69 194 13386 0 0
11 Concreting Materials for guy sets (Without Cement) Nos 9 158 1422 0 0
13 Labour charges
a) Casual 51642
b) Regular 10328
1) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 59
Providing 2 Pole Structrues at the Tapping Point Using 9Mtrs PSCC Poles of 300 Kg WL
SL.
Paritculars Unit Qty Material cost Labour Cost
No
1 DP Structure using 9 Mtrs PSCC Poles of 300Kg WL Set 1 13241 13241 3252 3252
Labour Charges
a) Casual 5488
b) Regular 1098
Note: 1) Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 60
SL.
Paritculars Unit Qty Material cost Labour Cost
No
5 11 KV, 5KN Polymeric Pin Insulator (24mm Dia FRP Rod) Nos 3 194 582 0 0
10 Labour Charges
a) Casual 7671
b) Regular 1534
Note: Other charges such as service tax, ESI, PF and other applicable charges shall be loaded as per typical cost data sheet
COST DATA SHEET - 24
Erection of 3 Phase, 11kV/433V, 25kVA BEE – 3 Star Rated Distribution Transformer Centre Using
DPTS
25 KVA
Sl
Particulars Unit Qty Material Cost Labour Cost
No
Rate Amt Rate Amt
1 Part-A: TRANSFORMER
Single
Earthing materials pipe type for grounding as per
Electrode
6 Drawing No. BESCOM/GM/CP/15 & 34/ Dt: 3 1279 3837 573 1719
with
24.10.07
accessories
Caution/Danger Board as per Drawing No.
7 No 1 146 146 48 48
BESCOM/GM/CP/40/ Dt: 24.10.07
Anti Climbing Device (12mtrs/1Kg GI Barbed
8 Kgs 2 64 128 25 50
Wire) Lumpsum
12 Labour Charges
a) Casual 8030
b) Regular 1606
a) Casual 7475
b) Regular 1495
Part-B:
11kV Lightning Arester, Metal oxide,
14 Set of 3 Nos 1 2058 2058 71 71
9kV, 5kA
15 Labour Charges
a) Casual 71
b) Regular 14
20 Labour Charges
a) Casual 2977
b) Regular 595
22 Total (A+B+C)
Labour Charges:
a) Casual 11078
b) Regular 2216
Labour Charges:
a) Casual 10523
b) Regular 2105
Note: Provision for actual quantity of additional materials viz 45kN Disc Insulator, 11kV Pin Insulators ACSR/AAA
Conductor, Transparent Alkathine Tube, PG Clamps and Terminal Connectors etc. Whenever required may be made in the
estimate separately for
COST DATA SHEET -25
Erection of 3 Phase, 11kV/433V, 63kVA BEE – 3 Star Rated Distribution Transformer Centre Using
DPTS
63 KVA
Sl
Particulars Unit Qty Material Cost Labour Cost
No
Rate Amt Rate Amt
1 Part-A: TRANSFORMER
Single
Earthing materials pipe type for grounding as per
Electrode
6 Drawing No. BESCOM/GM/CP/15 & 34/ Dt: 3 1279 3837 573 1719
with
24.10.07
accessories
Caution/Danger Board as per Drawing No.
7 No 1 146 146 48 48
BESCOM/GM/CP/40/ Dt: 24.10.07
Anti Climbing Device (12mtrs/1Kg GI Barbed
8 Kgs 2 64 128 25 50
Wire) Lumpsum
12 Labour Charges
a) Casual 8030
b) Regular 1606
a) Casual 7475
b) Regular 1495
Part-B:
15 Labour Charges
a) Casual 71
b) Regular 14
18 11kV Solid Core Type HG Fuse Unit Set/ 3 nos 1 852 852 423 423
20 Labour Charges
a) Casual 3182
b) Regular 636
22 Total (A+B+C)
Labour Charges:
a) Casual 11283
b) Regular 2257
Labour Charges:
a) Casual 10728
b) Regular 2146
Note: Provision for actual quantity of additional materials viz 45kN Disc Insulator, 11kV Pin Insulators ACSR/AAA
Conductor, Transparent Alkathine Tube, PG Clamps and Terminal Connectors etc. Whenever required may be made in the
estimate separately for
COST DATA SHEET -26
Erection of 3 Phase, 11kV/433 V, 100kVA BEE – 3 Star Rated Distribution Transformer Centre Using
DPTS
100 KVA
Single
Earthing materials pipe type for grounding as per
Electrode
6 Drawing No. BESCOM/GM/CP/15 & 34/ Dt: 3 1279 3837 573 1719
with
24.10.07
accessories
12 Labour Charges
a) Casual 8381
b) Regular 1676
a) Casual 7959
b) Regular 1592
Part-B:
11kV Lightning Arester, Metal Oxide
14 Set of 3 Nos 1 2058 2058 71 71
9kV, 5kA
15 Labour Charges
a) Casual 71
b) Regular 14
16 Total for Part-B 2143
b) LT Distribution box for 100 kVA with MCB No 1 16600 16600 455 455
iii. PG Clamps - Rabbit to 120 Sqmm Nos 4 187 748 568 568
18 11kV Solid Core Type HG Fuse Unit Set/3 Nos 1 852 852 423 423
With LT Protection
With Distribution Box
kit
Total Cost (Material) 24931 38229
20 Labour Charges
22 Total (A+B+C)
Labour Charges:
Labour Charges:
Note: Provision for actual quantity of additional materials viz 45kN Disc Insulator, 11kV Pin Insulators ACSR/AAA Conductor,
Transparent Alkathine Tube, PG Clamps and Terminal Connectors etc. Whenever required may be made in the estimate
separately for
COST DATA SHEET - 27
Erection of 3 Phase, 11kV/433V, 250kVA 3 Star Rated Distribution Transformer Centre Using DPTS
250 KVA
Sl
Particulars Unit Qty Material cost Labour Cost
No
Rate Amt Rate Amt
1 Part-A: TRANSFORMER
Single
Earthing materials pipe type for grounding as per
Electrode
6 Drawing No. BESCOM/GM/CP/15 & 34/ Dt: 3 1279 3837 573 1719
with
24.10.07
accessories
Caution/Danger Board as per Drawing No.
7 No 1 146 146 48 48
BESCOM/GM/CP/40/ Dt: 24.10.07
Anti Climbing Device (12mtrs/1Kg GI Barbed
8 Kgs 2 64 128 25 50
Wire) Lumpsum
12 Labour Charges
a) Casual 7597
b) Regular 1519
a) Casual 7301
b) Regular 1460
a) Casual 71
b) Regular 14
a) LT Distribution box for 250kVA with MCCB No 1 16600 16600 455 455
17 iii. PG Clamps - Rabbit to 240 Sqmm Nos 4 281 1124 644 644
18 11kV Solid Core Type HG Fuse Unit Set/ 3 nos 1 852 852 423 423
20 Labour Charges
a) Casual 3303
b) Regular 661
22 Total (A+B+C)
Labour Charges:
a) Casual 10971
b) Regular 2194
Labour Charges:
a) Casual 10675
b) Regular 2135
Note: Provision for actual quantity of additional materials viz 45kN Disc Insulator, 11 kV Pin Insulators ACSR/AAA
Conductor, Transparent Alkathine Tube, PG Clamps and Terminal Connectors etc. Whenever required may be made in the
estimate separately for
While preparing estimates for turnkey / total tunkey projects please refer to Sl. No. ......... of General Guidelines vide a
1
to .... in Page No. ...........
COST DATA SHEET - 28
Erection of 3 Phase, 11kV/433V, 25kVA BEE 3 Star Rated Single Pole Mounted Transformer Centre on
9 Mtrs RCC Pole (Square Section)
Material cost Labour Cost
Sl. No Materials Unit Qty
Rate Amt Rate Amt
1 9 Mtr long RCC pole (Square Section) No 1 7165 7165 1060 1060
5 Single pole TC set suitable for 25 kVA Transformer Set 1 4213 4213 1016 1016
14 11kV Solid Core Type HG Fuse Unit Set/3 Nos 1 852 852 423 423
15 11kV, 200Amps, Single Break GOS Nos 1 7163 7163 636 636
Labour Charges
a) Casual 7952
b) Regular 1590
Total cost for erection of a single pole mounted 25kVA Transformer in Rs 104498
COST DATA SHEET - 29
Erection of 3 Phase, 11kV/433V, 63kVA BEE 3 Star Rated Single Pole Mounted Transformer Centre
on 9 Mtrs RCC Pole (Square Section)
Material cost Labour Cost
Sl. No Materials Unit Qty
Rate Amt Rate Amt
1 9 Mtr long RCC pole (Square Section) No 1 7165 7165 1060 1060
5 Single pole TC set suitable for 63 kVA Transformer Set 1 4213 4213 1016 1016
Single
Earthing materials pipe type for grounding as per
Electrode
7 Drawing No. BESCOM/GM/CP/15 & 34/ Dt: 3 1279 3837 573 1719
with
24.10.07
accessories
15 11kV, 200Amps, Single Break GOS Nos 1 7163 7163 636 636
19 Labour Charges
a) Casual 8157
b) Regular 1631
Total cost for Erection of a Single Pole Mounted 63kVA Transformer in Rs 150598
COST DATA SHEET - 30
Erection of 3 Phase, 11kV/433V, 100kVA BEE 3 Star Rated Single Pole Mounted Transformer Centre
on 9 Mtrs RCC Pole (Square Section)
Material cost Labour Cost
Sl. No Materials Unit Qty
Rate Amt Rate Amt
1 9 Mtr long RCC pole (Square Section) No 1 7165 7165 1060 1060
b) LT Distribution Box for 100kVA with MCB No 1 16600 16600 455 455
c) LT Wiring (From DTC to LT Line Through
Merering Box & LT Protection Kit/LT Distribution No 1
Box) SINGLE CIRCUIT
i. Al Lead Wire - 120 Sqmm Mtrs 45 107 4815
14 11kV Solid Core Type HG Fuse Unit Set/3 Nos 1 852 852 423 423
15 11kV, 200Amps, Single Break GOS Nos 1 7163 7163 636 636
Total
Total Cost for Erection of a Single Pole Mounted 100kVA Transformer with LT
236501
Distribution Box in Rs
Total Cost for Erection of a Single Pole Mounted 100kVA Transformer with LT
223149
Protection KIT in Rs
COST DATA SHEET-31
Erection of 3 Phase, 11kV/433V, 250 kVA Single Pole Mounted Distribution Transformer on 11.0 Mtr Spun Pole With
3 GOS System
Material cost Labour Cost
Sl No Materials Unit Qty
Rate Amt Rate Amt
2 Single Pole Transformer Structure Kit for 250kVA Set 1 23739 23739 2033 2033
3 HT Single Top Support with bolts, nuts & washers Sets 9 94 846 64 576
6 Alkathene Tube 19mm Dia and in coils of 30 Mtrs Coils 2 458 916 0 0
Single
Earthing materials pipe type for grounding as per
Electrode
17 Drawing No. BESCOM/GM/CP/15 & 34/Dt: 3 1279 3837 573 1719
with
24.10.07.
accessories
a) LT Distribution Box for 250kVA with MCCB No 1 16600 16600 455 455
b) LT Wiring (From DTC to LT Line via Metering
No 1
Box & LT Protection Kit) SINGLE CIRCUIT
19 11kV Lightning Arester, Metal Oxide, 9kV, 5kA Set/3 Nos 1 2058 2058 71 71
RMU (3 Way), One Incomer + Two Breakers + One out Will be Will be Will be Will be Will be
1 No 1 1 1 1
going (2OD + 2VL), 350 MVA, 630Amps intimated intimated intimated intimated intimated
2 Bed Conceting with CC 1:2:4 as per Labour Charges Cmt 5084 0.15 763 0.37 1881 0.53 2695 0.64 3254
Labour Charges
Note:-
The measurements for Earth work and concreting works have been provision as per the dimensions of the equipments of makes which are in use at present in
1
BESCOM. Detail for the measurement are furnished in the data sheet furnished in Page No. ………..
2 While preparing estimates for turnkey / total turnkey projects please refere to Sl. No. …….. To general guidelines vide a to …. page No. ……. To ……..
3 Revised Cost Data Sheet will be furnished after the rates for CSS, RMU etc. are finalised by the committee.
COST DATA SHEET - 33
Providing Compact RMU 11kV Class SF6/VCB Type (1 Incomer +1 Breaker +1 Outgoing)
2 Bed Conceting with CC 1:2:4 as per Labour Charges Cmt 5084 0.08 407 0.28 1424 0.43 2186 0.48 2440
Labour Charges
Note:-
The measurements for Earth work and concreting works have been provision as per the dimensions of the equipments of makes which are in use
1
at present in BESCOM. Detail for the measurement are furnished in the data sheet furnished in Page No. ………..
While preparing estimates for turnkey / total turnkey projects please refere to Sl. No. …….. To general guidelines vide a to …. page No. ……. To
2
……..
3 Revised Cost Data Sheet will be furnished after the rates for CSS, RMU etc. are finalised by the committee.
COST DATA SHEET-34
Providing Compact RMU 11kV Class SF6/VCB Type (1 OD)
2 Bed Conceting with CC 1:2:4 as per Labour Charges Cmt 5084 0.07 356 0.09 458 0.1 508 0.16 813
5 Providing Plinth with CC 1:2:4 on the Stone Masonary Cmt 5084 0 0 0 0 0 0 0.02 102
Labour Charges
Note:-
The measurements for Earth work and concreting works have been provision as per the dimensions of the equipments of makes which are in use at
1
present in BESCOM. Detail for the measurement are furnished in the data sheet furnished in Page No. ………..
2 While preparing estimates for turnkey / total turnkey projects please refere to Sl. No. …….. To general guidelines vide a to …. page No. ……. To ……..
3 Revised Cost Data Sheet will be furnished after the rates for CSS, RMU etc. are finalised by the committee.
COST DATA SHEET - 35
Providing Compact RMU 11kV Class SF6/VCB Type (1VL)
2 Bed Conceting with CC 1:2:4 as per Labour Charges Cmt 5084 0.07 356 0.09 458 0.1 508 0.16 813
Labour Charges
Note:-
The measurements for Earth work and concreting works have been provision as per the dimensions of the equipments of makes which are in use at
1
present in BESCOM. Detail for the measurement are furnished in the data sheet furnished in Page No. ………..
2 While preparing estimates for turnkey / total turnkey projects please refere to Sl. No. …….. To general guidelines vide a to …. page No. ……. To ……..
3 Revised Cost Data Sheet will be furnished after the rates for CSS, RMU etc. are finalised by the committee.
COST DATA SHEET - 36
Running Single Circuit 11kV, 3 Phase Power Line on 9 Mtr Supports with an Average Span of 30 Mtrs Using 3x95
Sqmm + 1x70 Sqmm Aerial Bunched Cables (ABC)
1 RCC Poles 9 Mtr long with 145 Kg WL Nos 10 5904 59040 1060 10600
2 PSC Poles 9 Mtr long with 200 Kg WL Nos 24 3380 81120 1060 25440
Pole clamp for HT/LT AB cable Sets 30 103 3090 192 5760
16 Labour Charges
a) Casual 80892.39
b) Regular 16178.48
Note
While preparing estimates for turnkey / total turnkey projects please refere to Sl. No. …….. To general guidelines vide
a to …. page No. ……. To ……..
COST DATA SHEET - 37
Running Single Circuit 1.1 kV 3 Phase 5 Wire Power Line on 9 Mtr Supports with Average Span of 40 Mtrs Using 3x95
+ 1x16 + 1x70 Sqmm Aerial Bunched Cables (ABC)
1 RCC Poles 9 Mtr long with 145 Kg WL Nos 10 5904 59040 1060 10600
2 PSC Poles 9 Mtr long with 200 Kg WL Nos 15 3380 50700 1060 15900
4 Three Phase Distribution box for 6 Connections Nos 20 2128 42560 538 10760
8 Pole clamp for HT/LT AB cable Sets 20 103 2060 192 3840
9 Universal Hook, Bolts & nuts Nos 16 314 5024 115 1840
18 Labour Charges
a) Casual 81519
b) Regular 16304
Note
While preparing estimates for turnkey / total turnkey projects please refere to Sl. No. …….. To general
guidelines vide a to …. page No. ……. To ……..
COST DATA SHEET - 38
Installing RLMU for the Existing 15/25kVA Distribution Transformer Center
Material cost
Sl No Particulars Unit Qty
Rate Amt
11 Labour Charges
a) Casual 3483
b) Regular 697
Note: (1) For 15 /25 kVA Transformer feeding to individual IP sets, use only one contactor & without MCCB .
While preparing estimates for turnkey / total tunkey projects please refer to Sl. No. ......... of General
1)
Guidelines vide a to .... in Page No. ...........
COST DATA SHEET - 39
Installing RLMU for the Existing 63 kVA Distribution Transformer Center
Material cost
Sl No Particulars Unit Qty
Rate Amt
10 Miscellaneous materials LS LS 23 23
11 Labour Charges
a) Casual 3483
b) Regular 697
While preparing estimates for turnkey/total tunkey projects please refer to Sl. No. ......... of General
1)
Guidelines vide a to .... in Page No. ...........
COST DATA SHEET - 40
Installing RLMU for the Existing 100kVA Distribution Transformer Center
Material cost
Sl No Particulars Unit Qty
Rate Amt
1 Metallic Enclosure with Busbars No 1 9849 9849
10 Miscellaneous materials LS LS 62 62
11 Labour Charges
a) Casual 3483
b) Regular 697
Note:
While preparing estimates for turnkey / total tunkey projects please refer to Sl. No. ......... of General
Guidelines vide a to .... in Page No. ...........
COST DATA SHEET - 41
Providing Compact Pre-fabricated Packaged Sub-station 11kV/433V
Sl
Particulars Unit Total Cost
No
Packaged Sub-station 11kV/433V consisting of 3 Way SF6/VCB insulated Compact RMU, Oil
1 cooled type Copper Wound Transformer and LT section with one ACB as incoming and 7 Nos
outgoing MCCB feeders and with enclosure made of electronically Galvanized sheet
Installing & fixing the compact pre-fabricated packaged sub-station 100/250/500/750/ 990
2 kVA transformer on the existing concrete plinth.(This does not include the cost of plinth, cable
duct,laying & termination of cable etc. provision for the same shall be made
Note :
While preparing estimates for turnkey/total turnkey projects please refere to Sl. No. …….. To general guidelines
1
vide a to …. page No. ……. To ……..
2 Revised Cost Data Sheet will be furnished after the rates for CSS, RMU etc. are finalised by the committee.
COST DATA SHEET - 42
For Providing Electronic Trivector Meters with Associated CT's Metering Box etc., on LT Side of
Distribution Transformer Center
Note:
While preparing estimates for turnkey/total turnkey projects please refere to Sl. No. …….. To general
guidelines vide a to …. page No. ……. To ……..
COST DATA SHEET - 43
For providing LT Capacitor to the Distribution Transformer
Material +
Total Material Labour
Labour
a) For 25KVA Transformer 1393 1011 382
While preparing estimates for turnkey / total turnkey projects please refere to Sl. No. …….. To general guidelines
1
vide a to …. page No. ……. To ……..
COST DATA SHEET - 44
Estimate for Carrying Out 1 to 2 (One to Two) Poles Works in respect of Ganga
Kalyana and Drinking Water Supply Works only
(Not applicaple for any other type of work)
SL. Consolidated
Paritculars Unit Qty
No Amount in Rs.
PART-A (Materials)
PART-B (Labour)
Consolidated labour charges involving 1 to
2 (ONE to TWO) pole works for Ganga
2 Nos 1 8829
Kalyana and Drinking Water supply works
only.
Note:-
1. The labour charges includes all works such as digging of pits, Erection of Poles,
Fixing of Cross Arms, Strining of conductor, fixing of Conductore accessories,
insulators, Fixing guy sets, Anti climbing device, spiral earth electrode and danger
board etc complete
2. No other labour charges or any other charges towards special locality allowance LC
Charges, additional labour charges, transportation charges etc., are payable.
4. Certificate has to be furnished by the section officer who prepares the estimate
that the estimates are not split to claim the above labour charges
5. The above rates are not applicable for works awarded on tender
COST DATA SHEET - 45
Estimate for Carrying Out 3 to 5 (THREE to FIVE) Poles Works in respect of Ganga
Kalyana and Drinking Water Supply Works only
(Not applicaple for any other type of work)
SL. Consolidated
Paritculars Unit Qty
No Amount in Rs.
PART-A (Materials)
Material cost Estimate shall be prepared
1
as per site requirement
PART-B (Labour)
Consolidated labour charges involving 3 to
5 (THREE to FIVE) pole works for Ganga
2 Nos 1 13949
Kalyana and Drinking Water supply works
only.
Note:-
1. The labour charges includes all works such as digging of pits, Erection of Poles,
Fixing of Cross Arms, Strining of conductor, fixing of Conductore accessories,
insulators, Fixing guy sets, Anti climbing device, spiral earth electrode and danger
board etc complete
2. No other labour charges or any other charges towards special locality allowance LC
Charges, additional labour charges, transportation charges etc., are payable.
4. Certificate has to be furnished by the section officer who prepares the estimate
that the estimates are not split to claim the above labour charges
5. The above rates are not applicable for works awarded on tender
COST DATA SHEET - 46
Estimate for carrying out 1 to 4 (ONE to FOUR) poles works in respect of Service Main Connection
and E&I Works only
(Not applicaple for any other type of work)
No. of
SL. Pole Consolidated
Paritculars Unit
No Works Amount in Rs.
Involved
PART-A (Materials)
Material cost Estimate shall be prepared as per
1
site requirement
PART-B (Labour)
Nos 1 4238
Consolidated labour charges for works 1 to 4 (ONE
to FOUR) poles including excavation of pit, pole Nos 2 5650
erection, fixing of cross arms, stringing of Nos 3 7063
2 conductor, fixing of conductor accessories, fixing Nos 4 8475
guy sets, fixing of anti climbing device, spiral earth
electrode, danger board etc if any (Applicable for 5& as per Common SR
both HT & LT Line) Above 2016-17
Note:-
1. The labour charges includes all works such as digging of pits, Erection of Poles, Fixing of Cross
Arms, Strining of conductor, fixing of Conductore accessories, insulators, Fixing guy sets, Anti
climbing device, spiral earth electrode and danger board etc complete
2. No other labour charges or any other charges towards special locality allowance LC Charges,
additional labour charges, transportation charges etc., are payable.
4. Certificate has to be furnished by the section officer who prepares the estimate that the
estimates are not split to claim the above labour charges
5. The above rates are not applicable for works awarded on tender
COST DATA SHEET - 47
Consolidated Labour charges for shifting of conductor terminations
and all other fittings existing on the deteriorated pole while
replaceing termination(cut point) poles(Does not include labour
chages for releasing and erection of pole)
Labour
Sl.
Description of the work Unit charges of
No.
the work
Single
Earthing materials pipe type for grounding as per
Electrode
6 Drawing No. BESCOM/GM/CP/15 & 34/ Dt: 3 1279 3837 573 1719
with
24.10.07
accessories
Caution/Danger Board as per Drawing No.
7 No 1 146 146 48 48
BESCOM/GM/CP/40/ Dt: 24.10.07
Anti Climbing Device (12mtrs/1Kg GI Barbed
8 Kgs 2 64 128 25 50
Wire) Lumpsum
will be
Total using 8 mtr PSC Poles 200kg WL 7475
intimated
12 Labour Charges
a) Casual 8030
b) Regular 1606
a) Casual 7475
b) Regular 1495
a) Casual 71
b) Regular 14
20 Labour Charges
a) Casual 2977
b) Regular 595
22 Total (A+B+C)
Labour Charges:
a) Casual 11078
b) Regular 2216
will be
Total using 8 mtr PSC Poles 200kg WL
intimated
Labour Charges:
a) Casual 10523
b) Regular 2105
Note: Provision for actual quantity of additional materials viz 45kN Disc Insulator, 11kV Pin Insulators ACSR/AAA Conductor,
Transparent Alkathine Tube, PG Clamps and Terminal Connectors etc. Whenever required may be made in the estimate
separately for
COST DATA SHEET - 62
Erection of 3 Phase, 11kV/433V, 63kVA BEE – 3 Star Rated Distribution Transformer Centre Using
DPTS With 9 Mtrs PSCC Pole 300Kg WL
63 KVA
Sl
Particulars Unit Qty Material Cost Labour Cost
No
Rate Amt Rate Amt
1 Part-A: TRANSFORMER
Single
Earthing materials pipe type for grounding as per
Electrode
6 Drawing No. BESCOM/GM/CP/15 & 34/ Dt: 3 1279 3837 573 1719
with
24.10.07
accessories
Caution/Danger Board as per Drawing No.
7 No 1 146 146 48 48
BESCOM/GM/CP/40/ Dt: 24.10.07
Anti Climbing Device (12mtrs/1Kg GI Barbed
8 Kgs 2 64 128 25 50
Wire) Lumpsum
a) Casual 8030
b) Regular 1606
a) Casual 7475
b) Regular 1495
15 Labour Charges
a) Casual 71
b) Regular 14
16 Total for Part-B 2143
18 11kV Solid Core Type HG Fuse Unit Set/ 3 nos 1 852 852 423 423
20 Labour Charges
a) Casual 2772
b) Regular 554
22 Total (A+B+C)
Labour Charges:
a) Casual 10873
b) Regular 2175
Will be
Total using 8 mtr PSC Poles 200kg WL
intimated
Labour Charges:
a) Casual 10318
b) Regular 2064
Note: Provision for actual quantity of additional materials viz 45kN Disc Insulator, 11kV Pin Insulators ACSR/AAA Conductor,
Transparent Alkathine Tube, PG Clamps and Terminal Connectors etc. Whenever required may be made in the estimate separately
for
COST DATA SHEET - 63
Erection of 3 Phase, 11kV/433V, 100kVA BEE – 3 Star Rated Distribution Transformer Centre Using
DPTS With 9 Mtrs PSCC Pole 300Kg WL
100 KVA
Sl No Particulars Unit Qty Material cost Labour Cost
Rate Amt Rate Amt
1 Part-A: TRANSFORMER
Single
Earthing materials pipe type for grounding as per
Electrode
6 Drawing No. BESCOM/GM/CP/15 & 34/ Dt: 3 1279 3837 573 1719
with
24.10.07
accessories
a) Casual 8381
b) Regular 1676
a) Casual 7959
b) Regular 1592
a) Casual 71
b) Regular 14
16 Total for Part-B 2143
b) LT Distribution box for 100 kVA with MCB No 1 16600 16600 455 455
iii. PG Clamps - Rabbit to 120 Sqmm Nos 4 187 748 568 568
18 11kV Solid Core Type HG Fuse Unit Set/3 Nos 1 852 852 423 423
With LT Protection
With Distribution Box
kit
Total Cost (Material) 24931 38229
20 Labour Charges
22 Total (A+B+C)
Labour Charges:
Note: Provision for actual quantity of additional materials viz 45kN Disc Insulator, 11kV Pin Insulators ACSR/AAA Conductor,
Transparent Alkathine Tube, PG Clamps and Terminal Connectors etc. Whenever required may be made in the estimate separately
for
COST DATA SHEET - 64
Erection of 3 Phase, 11kV/433V, 250kVA BEE – 3 Star Rated Distribution Transformer Centre Using
DPTS With 9 Mtrs PSCC Pole 300Kg WL
250 KVA
Sl.No Particulars Unit Qty Material cost Labour Cost
Rate Amt Rate Amt
1 Part-A: TRANSFORMER
Single
Earthing materials pipe type for grounding as per
Electrode
6 Drawing No. BESCOM/GM/CP/15 & 34/ Dt: 3 1279 3837 573 1719
with
24.10.07
accessories
Caution/Danger Board as per Drawing No.
7 No 1 146 146 48 48
BESCOM/GM/CP/40/ Dt: 24.10.07
Anti Climbing Device (12mtrs/1Kg GI Barbed
8 Kgs 2 64 128 25 50
Wire) Lumpsum
12 Labour Charges
a) Casual 7597
b) Regular 1519
a) Casual 7301
b) Regular 1460
a) Casual 71
b) Regular 14
a) LT Distribution box for 250kVA with MCCB No 1 16600 16600 455 455
17 iii. PG Clamps - Rabbit to 240 Sqmm Nos 4 281 1124 644 644
18 11kV Solid Core Type HG Fuse Unit Set/ 3 Nos 1 852 852 423 423
20 Labour Charges
a) Casual 3303
b) Regular 661
22 Total (A+B+C)
Labour Charges:
a) Casual 10971
b) Regular 2194
Will be
Total using 8 mtr PSC Poles 200kg WL
intimated
Labour Charges:
a) Casual 10675
b) Regular 2135
Note: Provision for actual quantity of additional materials viz 45kN Disc Insulator, 11 kV Pin Insulators ACSR/AAA Conductor,
Transparent Alkathine Tube, PG Clamps and Terminal Connectors etc. Whenever required may be made in the estimate
separately for
While preparing estimates for turnkey / total tunkey projects please refer to Sl. No. ......... of General Guidelines vide a to .... in
Page No. ...........
COST DATA SHEET - 65
Erection of 3 Phase, 11kV/433V, 25kVA BEE 3 Star Rated Single Pole Mounted Transformer Centre on
9 Mtrs PSCC Pole 300kg WL
Material cost Labour Cost
Sl. No Materials Unit Qty
Rate Amt Rate Amt
1 9 Mtr long PSCC pole of 300kg WL No 1 4549 4549 1060 1060
5 Single pole TC set suitable for 25 kVA Transformer Set 1 6356 6356 1016 1016
15 11kV, 200Amps, Single Break GOS Nos 1 7163 7163 636 636
Labour Charges
a) Casual 7952
b) Regular 1590
Total cost for erection of a single pole mounted 25kVA Transformer in Rs 103308
COST DATA SHEET - 66
Erection of 3 Phase, 11kV/433V, 63kVA BEE 3 Star Rated Single Pole Mounted Transformer Centre
on 9 Mtrs PSCC Pole 300kg WL
Material cost Labour Cost
Sl. No Materials Unit Qty
Rate Amt Rate Amt
1 9 Mtr long PSCC pole of 300kg WL No 1 4549 4549 1060 1060
5 Single pole TC set suitable for 63 kVA Transformer Set 1 6356 6356 1016 1016
Single
Earthing materials pipe type for grounding as per
Electrode
7 Drawing No. BESCOM/GM/CP/15 & 34/ Dt: 3 1279 3837 573 1719
with
24.10.07
accessories
14 11kV Solid Core Type HG Fuse Unit Set/3 Nos 1 852 852 423 423
15 11kV, 200Amps, Single Break GOS Nos 1 7163 7163 636 636
19 Labour Charges
a) Casual 8157
b) Regular 1631
Total cost for Erection of a Single Pole Mounted 63kVA Transformer in Rs 149408
COST DATA SHEET - 67
Erection of 3 Phase, 11kV/433V, 100kVA BEE 3 Star Rated Single Pole Mounted Transformer Centre
on 9 Mtrs PSCC Pole 300kg WL
Material cost Labour Cost
Sl. No Materials Unit Qty
Rate Amt Rate Amt
1 9 Mtr long PSCC pole of 300kg WL No 1 4549 4549 1060 1060
Single
Earthing materials pipe type for grounding as per
Electrode
7 Drawing No. BESCOM/GM/CP/15 & 34/Dt: 3 1279 3837 573 1719
with
24.10.07.
accessories
b) LT Distribution Box for 100kVA with MCB No 1 16600 16600 455 455
c) LT Wiring (From DTC to LT Line Through
Merering Box & LT Protection Kit/LT Distribution No 1
Box) SINGLE CIRCUIT
i. Al Lead Wire - 120 Sqmm Mtrs 45 107 4815
14 11kV Solid Core Type HG Fuse Unit Set/3 Nos 1 852 852 423 423
15 11kV, 200Amps, Single Break GOS Nos 1 7163 7163 636 636
Total
Total Cost for Erection of a Single Pole Mounted 100kVA Transformer with LT
193208
Distribution Box in Rs
Total Cost for Erection of a Single Pole Mounted 100kVA Transformer with LT
179856
Protection KIT in Rs
COST DATA SHEET - 68
Running Single Circuit 11kV, 3 Phase Power Line on 9 Mtr Supports with an Average Span of 30 Mtrs Using 3x95
Sqmm + 1x70 Sqmm Aerial Bunched Cables (ABC) using 9mtr PSCC pole of 300kg WL for Dead Ends and Anchor Points
1 PSCC Poles 9 Mtr long with 300 Kg WL Nos 10 4549 45490 1060 10600
2 PSC Poles 9 Mtr long with 200 Kg WL Nos 24 3380 81120 1060 25440
Pole clamp for HT/LT AB cable Sets 30 103 3090 192 5760
16 Labour Charges
a) Casual 80892
b) Regular 16178
While preparing estimates for turnkey / total turnkey projects please refere to Sl. No. …….. To general guidelines vide
a to …. page No. ……. To ……..
COST DATA SHEET - 69
Running Single Circuit 1.1 kV 3 Phase 5 Wire Power Line on 9 Mtr Supports with Average Span of 40 Mtrs Using 3x95
+ 1x16 + 1x70 Sqmm Aerial Bunched Cables (ABC) using 9mtr PSCC pole of 300kg WL for Dead Ends and Anchor
Points
SL. Material cost Labour Cost
Particulars Unit Qty
No Rate Amt Rate Amt
1 PSCC Poles 9 Mtr long with 300 Kg WL Nos 10 4549 45490 1060 10600
2 PSC Poles 9 Mtr long with 200 Kg WL Nos 15 3380 50700 1060 15900
4 Three Phase Distribution box for 6 Connections Nos 20 2128 42560 538 10760
8 Pole clamp for HT/LT AB cable Sets 20 103 2060 192 3840
9 Universal Hook, Bolts & nuts Nos 16 314 5024 115 1840
18 Labour Charges
a) Casual 81519
b) Regular 16304
While preparing estimates for turnkey / total turnkey projects please refere to Sl. No. …….. To general guidelines
vide a to …. page No. ……. To ……..