RIDGE VENT
blueprints transfers no right of ownership of the plan to the purchaser. The purchaser has merely
give away, make photocopies of, or reproduce in any form, the blueprints, plans, drawings or any
Drawings shall remain the property of Baumann Building Inc and are not to be used by the Home
Owner or any other party without written consent of Baumann Building Inc. Purchasing a set of
purchased a limited license to build that structure one time only. The purchaser may not sell,
othe rrelated artwork and/or data without written consent of Baumann Building Inc, is illegal.
FX3048
1X6 TRIM
RIDGE VENT
SECOND FLOOR GENERAL NOTES
4' - 4"
118' - 2 7/8" 1) VINYL SIDING ON ALL SIDES
8' - 1 1/8"
NOTED
24" OVERHANG
3) ALL HORIZONTAL TRIM PROJECTIONS TO HAVE
1X8 TRIM FLASHING. STEP FLASHING, KICKOUT-OUT FLASHING,
1' - 0 5/8"
MAIN FLOOR
109' - 1 1/8" 1X6 5) ALUM VENTED SOFFITS, ROOF PEAKS TO HAVE RIDGE
VENTS
1X3
1X6 TRIM ON FRONT 6) TYPAR HOUSE WRAP & AAMA 711 FLASHING TAPE TO BE
9' - 1 1/8"
COPYRIGHT
CORNERS APPLIED TO EXTERIOR
1' - 2 1/8"
MAIN T.O. SUBFLOOR
8' - 0"
95' - 3 7/8"
1862 SF
Unf L.L. 859 SF
FRONT ELEVATION 859 SF
1/4" = 1'-0"
B.O. FOUNDATION
90' - 9 7/8"
CONTRACTOR
RIDGE VENT
SECOND FLOOR
118' - 2 7/8"
VINYL CORNERS
ON REAR
8' - 1 1/8"
1X6 TRIM ON
FRONT CORNERS
Sketch
MAIN T.O. SUBFLOOR
100' - 0"
T.O. FOUNDATION
1' - 2 1/8"
98' - 9 7/8"
GRADE @ 6" BELOW T.O.W.
8' - 0"
CLIENT
LEFT ELEVATION
1/4" = 1'-0"
PROJECT NUMBER
21-014
B.O. FOUNDATION PLOT DATE
2/2/2021 4:32:44 PM
90' - 9 7/8"
A1.0 ELEVATIONS 1
21MS10 - Spec Home
blueprints transfers no right of ownership of the plan to the purchaser. The purchaser has merely
give away, make photocopies of, or reproduce in any form, the blueprints, plans, drawings or any
Drawings shall remain the property of Baumann Building Inc and are not to be used by the Home
Owner or any other party without written consent of Baumann Building Inc. Purchasing a set of
purchased a limited license to build that structure one time only. The purchaser may not sell,
othe rrelated artwork and/or data without written consent of Baumann Building Inc, is illegal.
RIDGE VENT
RIDGE VENT
SECOND FLOOR
118' - 2 7/8"
8' - 1 1/8"
1) VINYL SIDING ON ALL SIDES
1' - 0 5/8"
COPYRIGHT
LATH. LATH FASTENERS TYPE & SPACING PER ASTM VINYL SIDING
C1063. FINISED 2" ABOVE PAVING, 4" ABOVE FINISHED
109' - 1 1/8"
GRADE
9' - 1 1/8"
VENTS
1' - 2 1/8"
7) FINISHED GRADE @ 6" BELOW T.O. CONC WALL
VINYL CORNERS ON REAR MAIN T.O. SUBFLOOR
100' - 0"
T.O. FOUNDATION
98' - 9 7/8"
4' - 6"
T.O. DAYLIGHT
94' - 3 7/8"
3' - 6"
B.O. FOUNDATION
90' - 9 7/8"
RIDGE VENT
REAR ELEVATION
1/4" = 1'-0"
CONTRACTOR
4" / 1'-0" 4" / 1'-0"
SECOND FLOOR
118' - 2 7/8"
8' - 1 1/8"
6" / 1'-0"
MAIN FLOOR
109' - 1 1/8"
VINYL SIDING
9' - 1 1/8"
6" / 1'-0"
VINYL
CORNERS
1' - 2 1/8"
1X6 TRIM ON
FRONT MAIN T.O. SUBFLOOR
CORNERS
100' - 0"
T.O. FOUNDATION
98' - 9 7/8"
10" / 1'-0" 10" / 1'-0"
8' - 0"
CLIENT
1/4" = 1'-0" 1/8" = 1'-0"
PROJECT NUMBER
B.O. FOUNDATION 21-014
90' - 9 7/8" PLOT DATE
2/2/2021 4:32:46 PM
A2.0 ELEVATIONS 2
21MS10 - Spec Home
3
EX-L
EXTERIOR WALL F/L FAN / LIGHT SRF SURFACE RC ADJUSTABLE 6" HALF THREE WAY SWITCH
blueprints transfers no right of ownership of the plan to the purchaser. The purchaser has merely
give away, make photocopies of, or reproduce in any form, the blueprints, plans, drawings or any
Drawings shall remain the property of Baumann Building Inc and are not to be used by the Home
MOUNTED LIGHT MOUNTED LIGHT RECESSED CAN SWITCHED
Owner or any other party without written consent of Baumann Building Inc. Purchasing a set of
DUPLEX
purchased a limited license to build that structure one time only. The purchaser may not sell,
FAN
othe rrelated artwork and/or data without written consent of Baumann Building Inc, is illegal.
F OUTLET
RL GFCI
A/V CONNECTION
FLUORESCENT STRIP
LIGHT
FL CEILING FAN W/ LIGHT GROUND FAULT
CIRCUIT
SINGLE SWITCH Unf L.L.
BARE LIGHT
EX-L
RL INTERRUPTER
859 SF
FURN
4
S P
220V OUTLET SMOKE ALARM PENDENT FIXTURE FOUR WAY SWITCH WALL MOUNTED SCONCE AP ALARM PANEL UP
S
CO
SMOKE/CO ALARM
SP IN-CEILING SPEAKER
ELECTRICAL PANEL
ELECTRICAL LEGEND
RL RL RL RL 1/2" = 1'-0"
FURN
CO
SRF
RL RL
COPYRIGHT
52' - 2"
UP 4' - 0" 6' - 2" 12' - 4" 29' - 8"
RL RL
EGRESS 5' - 0" 6' - 0" 12' - 3 1/2" 6' - 4 1/2"
SH3660-2
10' - 0"
LOWER FLOOR PLAN - ELECTRICAL
3/16" = 1'-0"
19' - 4"
LVL
FROST WALL
17' - 4"
CONTRACTOR
FASTENER PER TRUSS 2X6 STUD SUPPORT
MANUFACTUERERS WALL ON 2X6 TREATED
SUMP BOTTOM PLATE APPROX TRUNK LINE
INSTRUCTIONS
8' - 0"
UNFINISHED
MIN R38 BLOWIN- STORAGE
IN CELLULOSE
31' - 0"
INSULATION 15' - 9 1/2" 3' - 7 1/2" 3' - 7 1/2" 18' - 11 1/2"
ICE AND WATER SHIELD
13' - 8"
2868 2868 2868
ALL SUPPORTING HEADERS WITH
OPENINGS OF 72" OR LESS TO BE
FURN
CONSTRUCTED OF 2X10 DOUG FIR
UNLESS OTHERWSIE SPECIFIED 2X6 TREATED SILL ON 8
X 8'0 CONC WALL
6' - 4"
UP
Spec Home
11-7/8" LPI 20Plus FLOOR
13' - 8"
JOIST
UNFINISHED STORAGE
OFFSET WALL ABOVE 4"
5' - 8"
5/8" DRYWALL CEILING GENERAL FOUNDATION NOTES
1) CONC WALL HEIGHT IS 8'-0" 21' - 2"
1' - 8"
FOOTING SCHEDULE
VINYL SIDING ON 7/16 OSB SHEATING WALL, 16" O.C. WITH MIN R15 SAND(SW) CLAY(ML)
CELLULOSE INS, 6 MIL POLY OFFSET WALL
RANCH 16"X8" 21"X6"
VAPOR BARRIER ON WARM 2X6 TREATED SILL ON 8 ABOVE 4"
2-STRY 19"X8" 25"X7"
SIDE X 8'0 CONC WALL
ALL INTERIOR SUPPORT WALLS TO BE 16"X8"
19' - 8"
4' - 0"
3/4" OSB T&G FLOORING ON
11-7/8" LPI 20Plus FLOOR
3) WATCHDOG WATERPROOFING APPLIED TO 10"
JOIST
FOUNDATION WALLS
#6 VERTICAL REBAR 35" O.C. @ 8' WALLS ON 4) ALL INTERIOR & EXTERIOR STUD BEARING WALLS 2X4 TREATED SILL ON 6
UNBALANCED FILL WALLS ONLY TO BE 2X4 CONSTRUCTION @ 16" O.C. W/ TREATED X 3'6 CONC. WALL
#4 HORIZONTAL REBARD @ 24" O.C. BASE PLATE. (2X6 FOR 2-STORY HOMES)
13' - 8"
5) #6 VERTICAL REBAR 35" O.C. @ 8' WALLS ON 2X4 TREATED SILL ON 6
R13 BATT INSULATION FILL WITH SAND
UNBALANCED FILL WALLS ONLY. #4 HORIZONTAL X 3'6 CONC. WALL
2X6 TREATED SILL ON 8 X 8'0
SILL SEAL REBAR @ 24" O.C. 13' - 8" 12' - 6"
CONC WALL
ANCHOR BOLT 6) PROVIDE 2x6 TREATED SLL PLATE ON ALL
EXTERIOR WALLS. USE 1/2" dia ANCHOR BOLTS W/
R6 ECOCELL ON CONC WALLS 7" EMBEDMENT INTO CONCRETE @ 4'-0" C/C.
CLIENT
WATCHDOG MIN 3.5" CONC FLOOR @DAYLIGHT & FROST WALLS. PLACE @ 4'-0" C/C
WATERPROOFING MAX FOR FULL HEIGHT BASEMENT WALLS.
2' - 0"
A3.0
GARAGE AND BASEMENT FLOOR 52' - 2"
-WALL BRACING METHOD: CS-G (TYP),
CS-PF AT 3RD STALL DOOR WALL
blueprints transfers no right of ownership of the plan to the purchaser. The purchaser has merely
give away, make photocopies of, or reproduce in any form, the blueprints, plans, drawings or any
Drawings shall remain the property of Baumann Building Inc and are not to be used by the Home
Owner or any other party without written consent of Baumann Building Inc. Purchasing a set of
10" HEADER
purchased a limited license to build that structure one time only. The purchaser may not sell,
othe rrelated artwork and/or data without written consent of Baumann Building Inc, is illegal.
DW
WD
Main Floor
2X6 STUD
RC
2X6 STUD
RC
FL
10" HEADER
JACK
RC DW STUD
D
RC
S
BOTTOM PLATE
3/4" OSB
S
DN UP CO LPI FLOOR JOIST
RC
SRF
SRF (2) LSL KING 48' - 2"
(1) LSL KING STUD, STUD, (1) LSL KING STUD,
SRF 6' - 2" 12' - 4" 29' - 8"
CONTINUOUS FROM CONTINUOUS CONTINUOUS FROM
F/L PLATE TO PLATE FROM PLATE PLATE TO PLATE
F/L 4' - 1" 2' - 1" 6' - 2" 6' - 2" 4' - 3 1/2" 4' - 2 1/2" 4' - 2 1/2" 4' - 5 1/2" 6' - 1 1/2" 6' - 4 1/2"
TO PLATE EGRESS
JACK STUD JACK STUD
COPYRIGHT
SH3660-2
10' - 0"
EGRESS TEMP
RC RC
Dining Room 6068 SLIDER
11'-9" x 12'-10"
EGRESS
19' - 4"
SH3672 FX5472 SH3672 SH3660-2
GIRDER TRUSS
SEE TALL
WALL DETAIL
5' - 9"
17' - 2" 12' - 6"
15' - 7 1/2"
15' - 7 1/2"
$3100 Master Bedroom
16' - 9 3/4"
3/16" = 1'-0" 12'-2" x 15'-0" FX6018
6' - 0"
GL3642 Great Room
16'-8" x 16'-7"
DW
3' - 2 1/2"
GENERAL NOTES
D
1) MAIN FLOOR WALL HEIGHT IS 9'-1 1/8" 2' - 2" 2' - 3 1/2"
SECOND FLOOR WALL HEIGHT IS 8'-1 1/8" 2X6 WALL
2' - 3 1/2"
8' - 0"
2) ALL EXTERIOR WALL SHOWN ARE 2X4 STUDS @ 16" O.C.
CONTRACTOR
2X6 WALL
W
WITH 7/16" SHEATHING (UNLESS OTHERWISE NOTED) 2468
4' - 9 1/2"
LAUNDRY
3) ALL INTERIOR WALLS ARE 2X4 STUDS @ 16" O.C.
DECK DETAIL
2' - 6"
(UNLESS OTHERWISE NOTED) 4' - 9" 7' - 9" 3' - 3 1/2" 3' - 7 1/2" 3' - 7 1/2" 6' - 5 1/2" 2868 2668
13' - 8"
2X4 TREATED TOP 4) ALL EXTERIOR ROOF SHEATHING TO BE 7/16" OSB ON 2868
54' - 8"
54' - 8"
RAIL CAPPED W/ 5/4 x PRE-ENGINEERED ROOF TRUSSES 24" O.C. 2868 PKT 3470 DN UP
5' - 3 1/2"
6 2X2 TREATED 3' - 7 1/2" 8' - 10 1/2"
SPINDLES OR SIMILAR 5) ALL SUPPORTING HEADERS WITH OPENINGS OF 72" OR
3' - 8"
GALVANIZED JOIST
7' - 4"
LESS TO BE CONSTRUCTED OF 2X10 DOUG FIR UNLESS SH2448
HANGERS PER CODE 5/4 x 6 MIN OTHERWISE NOTED. DOUBLE LAP STUDS UNDER ENDS
std
ATTACHED TO RIM TREATED OF ALL HEADERS OVER 48". 2468 PKT HALF
JOIST DECKING BATH
4068 Bifold 3470
6) FASTENER PER TRUSS MANUFACTURERS
2' - 0"
DBL WALL MASTER
INSTRUCTIONS
4' - 3 1/2"
GALVANIZED FLASHING (2)2X12 BEAM TO SUPPORT BENCH BATH
PER CODE REQUIRED JOIST BOLTED TO 4X6 2468 SH2448
7) STRUCTURAL LOADS: 2868 Lower
2' - 3"
POSTS
CLEAR SPACE BETWEEN
FLOOR LIVE LOAD = 40 CONC WALL BELOW stairs
1' - 0"
SPINDLES NOT TO EXCEED 4" HURRICANE STRAPS
ROOF LIVE LOAD = 40 6' - 5 1/2" 11' - 7 1/2" 3' - 5" unfinished ?
4' - 2"
NOTE: ALL LUMBER TO BE WIND EXPOSURE CATEGORY = EXPOSURE B ATTIC ACCESS
5' - 9 1/2"
5' - 9 1/2"
4X6 TREATED POST SOIL BEARING ASSUMED 2000 PSF CANTILEVER
TREATED LUMBER & ALL
NAILS/SCREWS TO BE COATED ON MIN. 24X24X8 SOIL TYPE: ____________
OR STAINLESS STEEL CONC PAD 42" BELOW SECOND FLOOR LINE
GRADE 8) WINDOW TAGS: LETTERS INDICATE WINDOW TYPE, EGRESS TEMP
BLOCKING AT POST BETWEEN FOLLOWED BY WIDTH IN INCHES, ENDING IN HEIGHT IN
ATTACH 2X12 DECK LEDGER WITH GRKs 3068
DECK JOIST TO ALLOW FOR 2 INCHES. ex: SH2448 = Single Hung 24" x 48"
CONNECTION POINTS (2) GRK EVERY 6" O.C. STAGGERED SO THE BOTTOM CONC WALL BELOW CONC PORCH
a. ALL OPERABLE WINDOWS WITH SILLS LOCATED 6"
FASTERS PER SIDE GRK PENETRATES THE BASEMENT TOP PLATE
MORE THAN 6' ABOVE THE OUTSIDE GRADE SHALL FX2424 FX2424
3' - 9 1/4"
19' - 8"
HAVE A CLEAR OPENING TO FINISHED FLOOR
4' - 0"
HEIGHT OF 24" OR MORE, OR HAVE APPROVED CENTER OF BEAM
WINDOW OPENING LIMITER DEVICES INSTALLED.
b. HEADER HEIGHTS WITH 2X10 HEADER @ 6' 11-3/8".
(DBL TOP PLATE, HEADER, STUD)
1.5"
min
9) DOOR TAGS: FIRST TWO NUMBERS INDICATE WIDTH IN
FEET AND INCHES. LAST TWO NUMBERS INDICATE Garage
HEIGHT IN FEE AND INCHES. ex: 2868 = 2'8 X 6'8
13' - 8"
3.5" CONC FLOOR
a. GARAGE DOOR R.O. WIDTH TO BE 16'-0" WHEN
4-1/2"
SLOPE
31-1/2"
min 11/4" BELOW T.O. CONC WALL. MAIN 2' STALL TO BE FRAMED
lin
i
6'-8"
ce
CLIENT
ha
CS-G 16 X 8
34"-38"
9"
11) ATTIC ACCESS; 20X30 ATTIC ACCESS, IF ACCESS IS GARAGE DOOR
3/ " - 1- 1/4"
4 FROM A HEATED SPACE, STAPLE INSULATION TO BACK OF
max spindles LID AND GASKET OPENING
8-1/4"
min
4"sphere max PROJECT NUMBER
max 12) WALLS BETWEEN HOUSE AND GARAGE TO BE 9' - 11" 3' - 3" 4' - 0" 5' - 0" 4' - 0"
21-014
DRYWALL, CEILING OF GARAGE TO BE DRYWALL
11' - 0" 11' - 0" 13' - 2" 13' - 0" PLOT DATE
13) 2 CONTINUOUS RUN FANS THROUGH-OUT HOME 4' - 0" 22' - 0" 26' - 2" 2/2/2021 4:32:47 PM
(R311.7.8-R312.1) (R311.7)
Handrails and Guardrails Stair Requirements 52' - 2"
3/16" = 1'-0"
SRF
S
ELECTRICAL
SRF
S
CO
S
SRF
F/L
SRF
RC
RC
2468
10' - 7"
10'-0" X 12'-9"
Bedroom 2
6' - 2"
2868
8' - 8 1/2"
5068 Bifold
std
7' - 0 1/2"
EGRESS
SH3660-2
2' - 4"
11'-9" x 11'-0"
Bedroom 3
6' - 1"
2468
BATH
6' - 2"
UPPER
10' - 11"
2868
3' - 7 1/2"
35' - 8"
1/4" = 1'-0"
FX2424
5' - 3 1/2"
29' - 6"
FX3660
3' - 7 1/2"
3' - 8 1/2"
HALF WALL
FX3042
FX5460
3' - 7 1/2"
14' - 2"
FX3042
FX3660
Owner or any other party without written consent of Baumann Building Inc. Purchasing a set of
PLOT DATE
Spec Home blueprints transfers no right of ownership of the plan to the purchaser. The purchaser has merely
purchased a limited license to build that structure one time only. The purchaser may not sell,
Mason Lake Estates Lot 10 give away, make photocopies of, or reproduce in any form, the blueprints, plans, drawings or any
PROJECT NUMBER
othe rrelated artwork and/or data without written consent of Baumann Building Inc, is illegal.
SECOND FLOOR PLAN
A5.0
21MS10 - Spec Home