You are on page 1of 2

Tabel Perhitungan Jumlah Driven Pile (Lantai 1 Convention)

Prestressed Spun Concrete Piles, diam. 450mm, tbl. 80mm, Class A2, Allowable Axial Load 145,80 ton.
(setara produk PT. Wijaya Karya)
Joint OutputCase U3 DAYA DUKUNG TIANG PANCANG (Ton) JMLH. TIANG
Text Text Ton Prestressed Spun Pile diam. 50cm (D=50cm)
1 COMB1 34.3139 145.80 1.00
2 COMB1 61.3106 145.80 1.00
3 COMB1 31.3583 145.80 1.00
4 COMB1 55.4937 145.80 1.00
5 COMB1 52.5503 145.80 1.00
6 COMB1 72.8157 145.80 1.00
7 COMB1 30.7909 145.80 1.00
8 COMB1 38.3136 145.80 1.00
9 COMB1 34.3565 145.80 1.00
10 COMB1 38.5255 145.80 1.00
11 COMB1 30.0133 145.80 1.00
12 COMB1 81.6468 145.80 1.00
13 COMB1 33.6812 145.80 1.00
14 COMB1 62.6003 145.80 1.00
15 COMB1 59.974 145.80 1.00
16 COMB1 62.7456 145.80 1.00
17 COMB1 109.8808 145.80 1.00
18 COMB1 105.2246 145.80 1.00
19 COMB1 109.5654 145.80 1.00
20 COMB1 86.6799 145.80 1.00
TABLE: Program Control
ProgramName Version CurrUnits SteelCode ConcCode AlumCode
Text Text Text Text Text Text
SAP2000 8.0.8 Ton, m, C AISC-ASD89 ACI 318-99 AA-ASD 2000

You might also like