You are on page 1of 11

Produced on 15/02/2021 with Xpress Selection V9.1.0 - database DIL 16.1.

Project name PSA OFICINAS SAN ISIDRO


Project address Peru
Reference LIMA
Client name KAMSAU
Revision GCM_01

Selection parameters of the indoor units can be found under the chapter Indoor unit details
Selection parameters of the outdoor units can be found under the chapter Outdoor unit details
Only the data published in the data book are correct. This program uses close approximations of these data.

1. Material List
Model Type Model Name Qty Description
Outdoor unit RXQ18TATL 2 Cooling only VRV IV(TATL)
Indoor unit FXAQ20AVM 8 VRV A(AVM) - Unidad montada en pared
FXAQ25AVM 4 VRV A(AVM) - Unidad montada en pared
FXAQ32AVM 6 VRV A(AVM) - Unidad montada en pared
FXAQ63AVM 2 VRV A(AVM) - Unidad montada en pared
FXHQ100MAVE 3 VRV H - Unidad suspendida del techo
FXHQ32MAVE 2 VRV H - Unidad suspendida del techo
Branch unit BHFP22P100 1 Outdoor unit multi connection piping kit
KHRP26A22T 16 Refnet branch piping kit
KHRP26A33T 2 Refnet branch piping kit
KHRP26A72T 5 Refnet branch piping kit
KHRP26A73T + KHRP26M73TP 1 Refnet branch piping kit
Option or add-on BRC1E63 25 Wired Remote Controller (Navigation Remote Controller)
Refrigerant R410A 15.2kg Extra refrigerant charge
Copper pipe Piping ¼" 41.5m Copper pipe
Piping ⅜" 79.7m Copper pipe
Piping ½" 46.2m Copper pipe
Piping ⅝" 74.2m Copper pipe
Piping ¾" 28.2m Copper pipe
Piping ⅞" 9.5m Copper pipe
Piping 1⅛" 16.9m Copper pipe
Piping 1⅝" 20.0m Copper pipe

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

SPEC IN
GCM
Page 1
2. Indoor Unit Details
2.1. Table of Abbreviations
Name Logical name of the device
FCU Device model name
Tmp C Indoor conditions in cooling (dry bulb temp. / wet bulb temp.)
Rq TC Required total cooling capacity
Max TC Available total cooling capacity
Rq SC Required sensible cooling capacity
Max SC Available sensible cooling capacity
Tevap Evaporating temperature of indoor unit coil
Tdis C Indoor unit discharge air temperature in cooling
Airflow Supplied airflow
Sound Sound pressure low and high
PS Power supply (voltage and phases)
MCA Minimum Circuit Amps
WxHxD WidthxHeightxDepth
Wght Weight of the device

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

SPEC IN
GCM
Page 2
2.2. VRV - 1 - RXQ36TATL
Capacity data at conditions and connection ratio (104%) as entered
Name FCU Tmp C Rq TC Max TC Rq SC Max SC Tevap Tdis C Airflow
°C BTU/h BTU/h BTU/h BTU/h °C °C cfm
UE 3-01 FXHQ100MAVE 24.0 / 17.0 n/a 36681 n/a 27092 Auto 8.5 883
UE 3-02 FXHQ100MAVE 24.0 / 17.0 n/a 36681 n/a 27092 Auto 8.5 883
UE 3-03 FXAQ25AVM 24.0 / 17.0 n/a 9184 n/a 7875 Auto 12.0 332
UE 3-04 FXAQ25AVM 24.0 / 17.0 n/a 9184 n/a 7875 Auto 12.0 332
UE 3-05 FXAQ32AVM 24.0 / 17.0 n/a 11808 n/a 9226 Auto 10.5 346
UE 3-06 FXAQ32AVM 24.0 / 17.0 n/a 11808 n/a 9226 Auto 10.5 346
UE 3-07 FXAQ25AVM 24.0 / 17.0 n/a 9184 n/a 7875 Auto 12.0 332
UE 3-08 FXAQ25AVM 24.0 / 17.0 n/a 9184 n/a 7875 Auto 12.0 332
UE 3-09 FXAQ20AVM 24.0 / 17.0 n/a 7336 n/a 6565 Auto 13.7 321
UE 3-10 FXHQ32MAVE 24.0 / 17.0 n/a 11772 n/a 10189 Auto 11.9 424
UE 3-11 FXAQ32AVM 24.0 / 17.0 n/a 11808 n/a 9226 Auto 10.5 346
UE 2-01 FXAQ20AVM 24.0 / 17.0 n/a 7336 n/a 6565 Auto 13.7 321
UE 2-02 FXAQ20AVM 24.0 / 17.0 n/a 7336 n/a 6565 Auto 13.7 321
UE 2-03 FXAQ20AVM 24.0 / 17.0 n/a 7336 n/a 6565 Auto 13.7 321
UE 2-04 FXAQ32AVM 24.0 / 17.0 n/a 11808 n/a 9226 Auto 10.5 346
UE 2-05 FXAQ20AVM 24.0 / 17.0 n/a 7336 n/a 6565 Auto 13.7 321
UE 2-06 FXAQ32AVM 24.0 / 17.0 n/a 11808 n/a 9226 Auto 10.5 346
UE 2-07 FXAQ20AVM 24.0 / 17.0 n/a 7336 n/a 6565 Auto 13.7 321
UE 2-08 FXAQ20AVM 24.0 / 17.0 n/a 7336 n/a 6565 Auto 13.7 321
UE 2-09 FXAQ32AVM 24.0 / 17.0 n/a 11808 n/a 9226 Auto 10.5 346
UE 2-10 FXAQ63AVM 24.0 / 17.0 n/a 23288 n/a 18443 Auto 10.1 671
UE 2-11 FXAQ63AVM 24.0 / 17.0 n/a 23288 n/a 18443 Auto 10.1 671
UE 2-12 FXAQ20AVM 24.0 / 17.0 n/a 7336 n/a 6565 Auto 13.7 321
UE 2-13 FXHQ32MAVE 24.0 / 17.0 n/a 11772 n/a 10189 Auto 11.9 424
UE 1-01 FXHQ100MAVE 24.0 / 17.0 n/a 36681 n/a 27092 Auto 8.5 883

Required cooling capacity towards the outdoor unit: 346438BTU/h.

The calculation shows the peak discharge temperatures (lowest temperature in case of cooling mode / highest
temperature in case of heating mode), assuming the indoor unit is running at full load at the given indoor
temperature design conditions. In practice the discharge temperature will modulate based on actual capacity
requirements and during defrost mode (heating mode).
The analysis of the suction and discharge temperature values may help in preventing a cold draft and to ensure a
thermal comfort level.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

SPEC IN
GCM
Page 3
Name Sound PS MCA WxHxD Wght
dBA A mm kg
UE 3-01 37-45 220V 1ph 1.3 1400×195×680 33
UE 3-02 37-45 220V 1ph 1.3 1400×195×680 33
UE 3-03 28.5-35 220V 1ph 0.6 795×290×266 12
UE 3-04 28.5-35 220V 1ph 0.6 795×290×266 12
UE 3-05 28.5-37.5 220V 1ph 0.6 795×290×266 12
UE 3-06 28.5-37.5 220V 1ph 0.6 795×290×266 12
UE 3-07 28.5-35 220V 1ph 0.6 795×290×266 12
UE 3-08 28.5-35 220V 1ph 0.6 795×290×266 12
UE 3-09 28.5-33 220V 1ph 0.6 795×290×266 12
UE 3-10 31-36 220V 1ph 0.9 960×195×680 24
UE 3-11 28.5-37.5 220V 1ph 0.6 795×290×266 12
UE 2-01 28.5-33 220V 1ph 0.6 795×290×266 12
UE 2-02 28.5-33 220V 1ph 0.6 795×290×266 12
UE 2-03 28.5-33 220V 1ph 0.6 795×290×266 12
UE 2-04 28.5-37.5 220V 1ph 0.6 795×290×266 12
UE 2-05 28.5-33 220V 1ph 0.6 795×290×266 12
UE 2-06 28.5-37.5 220V 1ph 0.6 795×290×266 12
UE 2-07 28.5-33 220V 1ph 0.6 795×290×266 12
UE 2-08 28.5-33 220V 1ph 0.6 795×290×266 12
UE 2-09 28.5-37.5 220V 1ph 0.6 795×290×266 12
UE 2-10 38.5-46.5 220V 1ph 0.7 1050×290×269 15
UE 2-11 38.5-46.5 220V 1ph 0.7 1050×290×269 15
UE 2-12 28.5-33 220V 1ph 0.6 795×290×266 12
UE 2-13 31-36 220V 1ph 0.9 960×195×680 24
UE 1-01 37-45 220V 1ph 1.3 1400×195×680 33

Outdoor unit placed 6.0m above the indoor units.


The minimum connection ratio for this height difference is 50%.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

SPEC IN
GCM
Page 4
3. Outdoor Unit Details
3.1. Table of Abbreviations
Name Logical name of the device
Model Device model name
▼ Optimized selection: Smaller outdoor model selected than standard proposed model
Tmp C Outdoor temperature in cooling
CC Available cooling capacity
Rq CC Required cooling capacity
EER EER at nominal conditions for standard efficiency series (nominal temperatures, 100% connection ratio and
without considering pipe length corrections)
Tmp H Outdoor conditions in heating (dry bulb temp. / wet bulb temp.)
HC Available heating capacity (integrated heating capacity)
Rq HC Required heating capacity
COP COP at nominal conditions for standard efficiency series (nominal temperatures, 100% connection ratio and
without considering pipe length corrections)
Piping Largest distance from indoor unit to outdoor unit
Bse Refr Standard factory refrigerant charge (5m actual piping length)
excluding extra refrigerant charge
For calculation of extra refrigerant charge refer to the databook
Ex Refr Extra refrigerant charge
PS Power supply (voltage and phases)
MCA Minimum Circuit Amps
WxHxD WidthxHeightxDepth
Wght Weight of the device

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

SPEC IN
GCM
Page 5
3.2. Outdoor Details
Name Model Comb Tmp C CC Rq CC EER (*) Tmp H HC Rq HC COP (*)
% °C BTU/h BTU/h BTU/h/W °C BTU/h BTU/h W/W
VRV - 1 RXQ36TATL ▼ 104 29.4 323277 (-6.7%) 346438 11.1

(*) The EER and COP values are calculated at nominal conditions: nominal temperatures, 100% connection ratio
and without considering pipe length corrections.

Name Model Piping Refrigerant


m Type Bse Refr Ex Refr
kg kg
VRV - 1 RXQ36TATL 55.7 R410A 21.0 15.2

Name Model PS MCA WxHxD Wght


A mm kg
VRV - 1 RXQ36TATL 220V 3ph
× RXQ18TATL 55 1240×1657×765 285
× RXQ18TATL 55 1240×1657×765 285

Sufficient distance should be respected between the modules according to the service & operation space rules as
mentioned in the databook.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

SPEC IN
GCM
Page 6
3.2.1. VRV - 1 - RXQ36TATL

Model Type Model Name Qty Description


Outdoor unit RXQ18TATL 2 Cooling only VRV IV(TATL)
Indoor unit FXAQ20AVM 8 VRV A(AVM) - Unidad montada en pared
FXAQ25AVM 4 VRV A(AVM) - Unidad montada en pared
FXAQ32AVM 6 VRV A(AVM) - Unidad montada en pared
FXAQ63AVM 2 VRV A(AVM) - Unidad montada en pared
FXHQ100MAVE 3 VRV H - Unidad suspendida del techo
FXHQ32MAVE 2 VRV H - Unidad suspendida del techo
Branch unit BHFP22P100 1 Outdoor unit multi connection piping kit
KHRP26A22T 16 Refnet branch piping kit
KHRP26A33T 2 Refnet branch piping kit
KHRP26A72T 5 Refnet branch piping kit
KHRP26A73T + KHRP26M73TP 1 Refnet branch piping kit
Option or add-on BRC1E63 25 Wired Remote Controller (Navigation Remote Controller)
Refrigerant R410A 15.2kg Extra refrigerant charge
Copper pipe Piping ¼" 41.5m Copper pipe
Piping ⅜" 79.7m Copper pipe
Piping ½" 46.2m Copper pipe
Piping ⅝" 74.2m Copper pipe
Piping ¾" 28.2m Copper pipe
Piping ⅞" 9.5m Copper pipe
Piping 1⅛" 16.9m Copper pipe
Piping 1⅝" 20.0m Copper pipe

Standard factory refrigerant charge (5m actual piping length) = 21.0kg


Extra refrigerant charge = 20.0m(ø¾") × 0.26 + 79.7m(ø⅜") × 0.057 + 41.5m(ø¼") × 0.022 + 12.2m(ø⅝") × 0.17 +
4.7m(ø½") × 0.11 + A + B = 15.2kg
A [ CR 104%, actual length 51.7m ] = 2.0kg
B [ 36HP ] = 0.0kg

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

SPEC IN
GCM
Page 7
4. Piping Diagrams
Pipes marked with a short red stripe in the diagrams must be connected to the device with a reducing joint.

4.1. Piping VRV - 1


VRV - 1
RXQ36TATL
RXQ18T ATL RXQ18TATL

⅝"×1⅛" ⅝"×1⅛"
BHFP22P100

20.0m 9.2m 0.8m 1.0m


¾"×1⅝" ⅝"×1⅛" ⅜"×⅝" ¼"×½"
KHRP26A73T + KHRP26A72T KHRP26A22T
KHRP26M73T P
UE 3-09
FXAQ20AVM
1.2m 1.0m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 3-08
FXAQ25AVM
1.8m 2.5m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 3-07
FXAQ25AVM
6.0m
¼"×½"

UE 3-06
FXAQ32AVM
1.0m 3.0m
½"×1⅛" ¼"×½"
KHRP26A72T

UE 3-11
FXAQ32AVM
3.2m 0.5m
½"×1⅛" ¼"×½"
KHRP26A72T

UE 3-10
FXHQ32MAVE
4.8m 3.0m
⅜"×⅞" ⅜"×⅝"
KHRP26A33T

UE 3-02
FXHQ100MAVE
1.8m 1.0m
⅜"×¾" ¼"×½"
KHRP26A22T

UE 3-03
FXAQ25AVM
3.2m 1.0m
⅜"×¾" ¼"×½"
KHRP26A22T

UE 3-04
FXAQ25AVM
1.0m 5.5m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 3-05
FXAQ32AVM
7.5m
⅜"×⅝"

UE 3-01
FXHQ100MAVE
3.0m 0.5m 1.5m 1.0m
⅝"×1⅛" ½"×1⅛" ⅜"×⅝" ¼"×½"
KHRP26A72T KHRP26A72T KHRP26A22T

UE 2-12
FXAQ20AVM
2.5m 1.0m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 2-13
FXHQ32MAVE
5.5m
⅜"×⅝"

UE 2-11
FXAQ63AVM
4.7m 1.2m 2.8m 1.0m
⅜"×⅞" ⅜"×⅝" ⅜"×⅝" ¼"×½"
KHRP26A33T KHRP26A22T KHRP26A22T

UE 2-08
FXAQ20AVM
2.8m
⅜"×⅝"

UE 2-10
FXAQ63AVM
7.0m
¼"×½"

UE 2-09
FXAQ32AVM
3.2m 1.0m
⅜"×¾" ¼"×½"
KHRP26A22T

UE 2-07
FXAQ20AVM
3.1m 3.4m 1.0m
⅜"×⅝" ⅜"×⅝" ¼"×½"
KHRP26A22T KHRP26A22T

UE 2-06
FXAQ32AVM
3.5m 1.0m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 2-04
FXAQ32AVM
2.5m
¼"×½"

UE 2-05
FXAQ20AVM
2.4m 1.0m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 2-03
FXAQ20AVM
2.0m 1.0m
⅜"×⅝" ¼"×½"
KHRP26A22T

UE 2-02
FXAQ20AVM
2.5m
¼"×½"

UE 2-01
FXAQ20AVM
16.0m
⅜"×⅝"

UE 1-01
FXHQ100MAVE

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

SPEC IN
GCM
Page 8
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

SPEC IN
GCM
Page 9
5. Wiring Diagrams
P1P2 = Please select the cable type and size in accordance with the databook.
F1F2 = Please select the cable type and size in accordance with the databook.

5.1. Wiring VRV - 1


P1,P2
VRV - 1
UE 3-09 BRC1E63
RXQ36TATL
FXAQ20AVM
IN F1,F2 F1,F2
RXQ18TATL L, N 0.6A 1ph
Q1,Q2 L1,L2,L3 P1,P2
55A 3ph UE 3-08 BRC1E63
FXAQ25AVM
RXQ18TATL F1,F2
Q1,Q2 L1,L2,L3 L, N 0.6A 1ph
55A 3ph P1,P2
UE 3-07 BRC1E63
FXAQ25AVM
F1,F2
L, N 0.6A 1ph
P1,P2
UE 3-06 BRC1E63
FXAQ32AVM
F1,F2
L, N 0.6A 1ph
P1,P2
UE 3-11 BRC1E63
FXAQ32AVM
F1,F2
L, N 0.6A 1ph
P1,P2
UE 3-10 BRC1E63
FXHQ32MAVE
F1,F2
L, N 0.9A 1ph
P1,P2
UE 3-02 BRC1E63
FXHQ100MAVE
F1,F2
L, N 1.3A 1ph
P1,P2
UE 3-03 BRC1E63
FXAQ25AVM
F1,F2
L, N 0.6A 1ph
P1,P2
UE 3-04 BRC1E63
FXAQ25AVM
F1,F2
L, N 0.6A 1ph
P1,P2
UE 3-05 BRC1E63
FXAQ32AVM
F1,F2
L, N 0.6A 1ph
P1,P2
UE 3-01 BRC1E63
FXHQ100MAVE
F1,F2
L, N 1.3A 1ph
P1,P2
UE 2-12 BRC1E63
FXAQ20AVM
F1,F2
L, N 0.6A 1ph
P1,P2
UE 2-13 BRC1E63
FXHQ32MAVE
F1,F2
L, N 0.9A 1ph
P1,P2
UE 2-11 BRC1E63
FXAQ63AVM
F1,F2
L, N 0.7A 1ph
P1,P2
UE 2-08 BRC1E63
FXAQ20AVM
F1,F2
L, N 0.6A 1ph
P1,P2
UE 2-10 BRC1E63
FXAQ63AVM
F1,F2
L, N 0.7A 1ph
P1,P2
UE 2-09 BRC1E63
FXAQ32AVM
F1,F2
L, N 0.6A 1ph
P1,P2
UE 2-07 BRC1E63
FXAQ20AVM
F1,F2
L, N 0.6A 1ph
P1,P2
UE 2-06 BRC1E63
FXAQ32AVM
F1,F2
L, N 0.6A 1ph
P1,P2
UE 2-04 BRC1E63
FXAQ32AVM
F1,F2
L, N 0.6A 1ph
P1,P2
UE 2-05 BRC1E63
FXAQ20AVM
F1,F2
L, N 0.6A 1ph
P1,P2
UE 2-03 BRC1E63
FXAQ20AVM
F1,F2
L, N 0.6A 1ph
P1,P2
UE 2-02 BRC1E63
FXAQ20AVM
F1,F2
L, N 0.6A 1ph
P1,P2
UE 2-01 BRC1E63
FXAQ20AVM
F1,F2
L, N 0.6A 1ph
P1,P2
UE 1-01 BRC1E63
FXHQ100MAVE
F1,F2
L, N 1.3A 1ph

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

SPEC IN
GCM
Page 10
6. Device Options
6.1. Outdoor Unit Options
Model Description Used by
BHFP22P100 Outdoor unit multi connection piping kit VRV - 1 [RXQ36TATL]

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

SPEC IN
GCM
Page 11

You might also like