DRAWING NOTES:
1 PROVIDE MINIMUM OF 2-4" PVC SCHEDULE 40 OR RIGID GALVANIZED STEEL CONDUITS
H ENCASED IN CONCRETE DUCT BANKS FOR TELEPHONE/DATA SYSTEM FROM UTILITY
POLE TO PULLBOX.

2 PROVIDE MINIMUM OF 1-4" PVC SCHEDULE 40 OR RIGID GALVANIZED STEEL CONDUITS


ENCASED IN CONCRETE DUCT BANKS FOR COUNTY FIBER PONS SYSTEM FROM UTILITY
POLE TO PULLBOX.

6 10 3 PROVIDE MINIMUM OF 1-4" PVC SCHEDULE 40 OR RIGID GALVANIZED STEEL CONDUITS


110 TAP
ENCASED IN CONCRETE DUCT BANKS FOR CABLE TV SYSTEM FROM UTILITY POLE TO
PULLBOX.
4 PROVIDE MINIMUM OF 1-4" PVC SCHEDULE 40 OR RIGID GALVANIZED STEEL CONDUITS
8
ENCASED IN CONCRETE DUCT BANKS FOR SPARE FROM UTILITY POLE TO PULLBOX. MONTGOMERY COUNTY
10
5 PROVIDE MINIMUM OF 4-4" PVC RIGID GALVANIZED STEEL CONDUITS IN CEILING SPACE MARYLAND
FOR TELEPHONE/DATA SYSTEM FROM MDF TO IDF.
DEPARTMENT OF GENERAL SERVICES
6 PROVIDE MINIMUM OF 4-4" PVC RIGID GALVANIZED STEEL CONDUITS IN CEILING SPACE OFFICE OF PLANNING &
IDF ROOM 207 2nd FLOOR FOR COUNTY FIBER PONS SYSTEM FROM UNDERSIDE OF BRIDGE C201.
DEVELOPMENT
7 PROVIDE 1-4" CONDUIT RGS AND WEATHERHEAD THROUGH ROOF FOR ANTENNA AND
5 9 WEATHER STATION CABLING PATHWAY TO IDF ROOM 207. 101 MONROE STREET
8 ROCKVILLE, MARYLAND 20850
10 8 PROVIDE 50 PAIR CAT5E VOICE RISER FROM MDF TO IDF.
10 9 PROVIDE 3 1-1/4" INNERDUCTS WITH PULL STRINGS IN EACH 4" CONDUIT.
PROJECT:
G 8 10
110 TAP 110 TAP
PROVIDE COAX RG-11 TRUNK CABLE FROM TAP IN MDF TO TAP IN IDF.
WHEATON LIBRARY & COMMUNITY RECREATION CENTER
11
UTILITY POLE PROVIDE COAX VIDEO AMPLIFIER.
11701 GEORGIA AVENUE, SILVER SPRING, MARYLAND 20902
AMP

11

4 3 2 1
ARCHITECT:
9 MDF ROOM 110 IDF ROOM 160 1ST FLOOR

PB PB PB

4 3 2 1
9

F
11720 BELTSVILLE DRIVE, SUITE 600
GARAGE / CALVERTON, MARYLAND 20705
T: 301-595-1000 F: 301-595-0089
SLAB 0N GRADE www.grimmandparker.com
CONSULTANT:

TELECOM RISER DIAGRAM


NO SCALE Wright Engineering, LLC
Consulting Engineers
853 Ripple Stream Court
Joppa, MD 21085
T: 410-877-6297 F: 866-635-0374
E www.wrightengineering.net

DRAWING NOTES:
10 1 SECURITY CAMERA : PROVIDE ¾” CONDUIT WITH PULL LINE
FROM SECURITY CAMERA IN EXPOSED CEILING AREAS TO

J
10 2nd FLOOR CEILING NEAREST IDF/MDF. SECURITY CAMERA AND CAT 6 CABLE TO
TELECOM RACK BY OWNER’S SECURITY CONTRACTOR.

IDF WI-FI 2 SECURITY CAMERA : PROVIDE ¾” CONDUIT WITH PULL LINE


4 6 7 8 FROM SECURITY CAMERA TO ACCESSIBLE CEILNG AREA
TOWARDS NEAREST IDF/MDF. SECURITY CAMERA AND CAT 6
CABLE TO TELECOM RACK BY OWNER’S SECURITY
5 CONTRACTOR.
PS 4 6 7 8
5 3 COMMUNICATIONS OUTLET : PROVIDE 2 GANG (4-11/16”
SQUARE ) BOX AND 1” CONDUIT WITH PULL LINE FROM
COMMUNICATIONS OUTLET IN EXPOSED CEILING AREAS TO
D NEAREST IDF/MDF. PONS ONT DEVICE, 48 VOLT POWER
CABLING AND CAT 6 CABLE TO TELECOM RACK BY OWNER’S
PONS CONTRACTOR.
POKE-THRU
2 2 2nd FLOOR 4 COMMUNICATIONS OUTLET : PROVIDE 2 GANG (4-11/16”
SQUARE ) BOX AND 1” CONDUIT WITH PULL LINE FROM
COMMUNICATIONS OUTLET TO ACCESSIBLE CEILNG AREA
TOWARDS NEAREST IDF/MDF. PONS ONT DEVICE, 48 VOLT
POWER CABLING AND CAT 6 CABLE TO TELECOM RACK BY
OWNER’S PONS CONTRACTOR.
JB 5 1ST FLOOR CEILING
5 POKE THRU DEVICE / FLOOR BOX : PROVIDE CAT 6 CABLES
IDF / MDF 5 (QUANTITY PER FLOOR PLANS ) FROM POKE THRU DEVICE /
FLOOR BOX TO CAT 6 PATCH PANEL IN NEAREST IDF/MDF
6 7 8 4 TELECOM ROOM. PROVIDE 1-1/4” CONDUIT FROM POKE THRU
DEVICE / FLOOR BOX TO ACCESSIBLE CEILING SPACE.
PROVIDE CONDUIT FOR ALL EXPOSED SPACES (IE GARAGE
PS 6 7 8 4 LEVEL).

6 VIDEO DROP : PROVIDE 2 GANG (4-11/16” SQUARE ) BOX AND IFB# 1062749
1-1/4” CONDUIT . PROVIDE CAT 6 CABLE & COAX CABLE FROM
VIDEO OUTLET DROP . PROVIDE CAT 6 CABLE TO CAT6 PATCH
PANEL IN NEAREST IDF/MDF TELECOM ROOM. PROVIDE 1-1/4”
CONDUIT FROM VIDEO OUTLET DROP TO ACCESSIBLE CEILING NO. DATE ISSUE DESCRIPTION
POKE-THRU SPACE. PROVIDE RG-6 COAX CABLE FROM VIDEO DROP TO

C 1ST FLOOR TAP LOCATED IN NEAREST IDF/MDF TELECOM ROOM.

7 WALL TELEPHONE : PROVIDE 2 GANG (4-11/16” SQUARE ) BOX


AND 1-1/4” CONDUIT . PROVIDE CAT 6 CABLE WALL
TELEPHONE OUTLET DROP . PROVIDE CAT 6 CABLE TO CAT6
PATCH PANEL IN NEAREST IDF/MDF TELECOM ROOM. PROVIDE
5 1-1/4” CONDUIT FROM WALL TELEPHONE OUTLET DROP TO
3 1 1 5
ACCESSIBLE CEILING SPACE.

8 SINGLE DATA JACK OUTLET : PROVIDE 2 GANG (4-11/16”


SQUARE ) BOX AND 1-1/4” CONDUIT . PROVIDE CAT 6 CABLE
3 FROM SINGLE DATA JACK OUTLET DROP . PROVIDE CAT 6
PROJECT NO: GP #21302
CABLE TO CAT6 PATCH PANEL IN NEAREST IDF/MDF TELECOM
ROOM. PROVIDE 1-1/4” CONDUIT FROM WALL SINGLE DATA
JACK OUTLET DROP TO ACCESSIBLE CEILING SPACE.

GARAGE / 9 EMERGENCY WALL TELEPHONE : PROVIDE 2 GANG (4-11/16”


SQUARE ) BOX AND 1-1/4” CONDUIT . PROVIDE CAT 6 CABLE
SLAB 0N GRADE EMERGENCY WALL TELEPHONE OUTLET DROP . PROVIDE CAT
6 CABLE TO CAT6 PATCH PANEL IN NEAREST IDF/MDF
TELECOM ROOM. PROVIDE 1-1/4” CONDUIT FROM EMERGENCY
WALL TELEPHONE OUTLET DROP TO ACCESSIBLE CEILING
SPACE.

10 WIRELESS ACCESS POINT (WIFI) DROP : PROVIDE JUNCTION


B BOX AND 1” CONDUIT WITH PULL LINE FROM
PASSIVE OPITICAL NETWORK SYSTEM (PONS) COMMUNICATIONS OUTLET TO ACCESSIBLE CEILNG AREA
TOWARDS NEAREST IDF/MDF. PONS ONT DEVICE, 48 VOLT
POWER CABLING AND CAT 6 CABLE TO TELECOM RACK BY

RISER DIAGRAM OWNER’S PONS CONTRACTOR.

NO SCALE
BID SET
MARCH 8, 2016

SHEET TITLE:

TELECOM RISER
DIAGRAM
A

SHEET NUMBER:

T-300
© GRIMM AND PARKER, P.C. 2015
Original Drawing is 30" x 42". Scale entities accordingly if reduced.
1 2 3 4 5 6 7 8 9 10

You might also like