You are on page 1of 1

CHINA CIVIL ENGINEERING CONSTRUCTION

Form: RQC-RTXR Rev: 0


CORPERATION
REAL TIME X-RAY REPORT Job No.:
Pipe No: O.D.: Wall: Len Report No.:
gth:
Test Spec.: Report Date: DVD No.:
Voltage kV: Current mA: IQI Type: Sensitivity:
SLAG (SLG) AND POROSITY (POR) DEFECTS RECORD
Slag Slag Slag or Porosity Min. Cumulative in any Location: Result
Test Width W Length Sep. 150mm SW/SJ/PE/JT Pass/Fail
Dia. Adj. Dia.
Date/Shift mm L mm S mm
D1 mm D2 mm No. Length/Dia

CIRCULAR SLAG & POROSITY – LIMITS (API 5L 44th Edition) ELONGATED SLAG - LIMITS
Cumulative slag length allowed in any
Cumulative diameter allowed in any 150mm of weld = 6.4mm for conditions
150mm of weld = 13mm for conditions
below
below
D1 D2 S Total No. D1 D2 S Total No.
3.2 3.2 50 2 1.6 0.8 9.5 varies
3.2 1.6 25 varies 1.6 0.4 6.4 varies W D S Total No.
3.2 0.8 13 varies 0.8 0.8 6.4 8 1.6 13 150 1
3.2 0.4 9.5 varies 0.8 0.4 4.8 varies 1.6 6.4 75 2
1.6 1.6 13 4 0.4 0.4 3.2 16 1.6 3.2 50 3
OTHER WELD DEFECTS RECORD (API 5L 44th Edition)
Defect Length L Location
Test Date/Shift Depth Dp mm Height H mm Result
Code mm SW/SJ/PE/JT

OTHER WELD DEFECT CODES AND LIMITS (API 5L 44th Edition)


Code Description Limit Code Description Limit
WUC Weld Undercut Dp<&=1.0 and L<=50 OCC Weld Off Centre 3mm with Penetration
WIC Weld Icicles Not allowed LPN Lack of Penetration Not allowed
CRK Crack Not allowed LSF Lack of Fusion Not allowed
HL Radial Mismatch H<&=2.4mm ARCB Arc Burns Not allowed
SS Arc Stop and Start Not allowed BT Burn Through Not allowed
TERMINOLOGY
SW Spiral Weld SJ Strip/Plate Joint PE Pipe End JT Jointer
Organisation Name Signature Date