FUNCTION SETTING
1. Standard: Water flow can be varied from 6000-
13000 LPH/1580-3400GPH by using the flow
control buttons.
2. Random: Water flow will start at 6000LPH/
Technological Aquatic Associated Manufacturing
1580GPH and gradually increase to the
Fax: (805) 383-3565. www.riopumps.com maximum flow of 13000LPH/3400GPH. 1 2 3 4
WARNING & SAFEGUARDS • Routine maintenance is required to ensure the WARNINGS! branch circuit supplying all power to water pumps 5. For best wave action, minimize obstacle in
maximum performance and the longevity of Seio and electrical aquarium equipment. If you do not the center of the aquarium.
Read and follow the guidelines to ensure This product may contain chemicals known to the
Wave pump. See Maintenance Guidelines. have a GFCI, have an electrician install one prior to 6. The remote control sensor is located at the
state of California to cause cancer and or birth
the proper use and application of this • The national code requires all aquarium defects or other reproductive harm. Wash your
operating any aquarium component. back of the pump. To ensure the pump can
Seio Wave pump. Failure to follow these equipment to be plugged into a GFCI (Ground read the remote control, the back of the
hand after handling this product. Note: It is important that the right pump and flow
guidelines may result in damage to the Fault circuit Interpreter) electrical outlet . pump must remain clean.
rate is being used for the given specific application.
aquatic environment and serious injury. • Do not operate if wire is damaged. It is your sole responsibilities to verify that the plug
Use the flow chart to determine the proper size 7. The remote control must be aimed directly
Operation and safety Precautions: • Do not plug into an extension cord or power strip. and the receptacle are clean and free of moisture
pump and tubing to be used for given application. at the back of the pump. The pump is
The National Code requires that a GFCI
• Failure to keep the Main strainer clean will and salt build up at all times. The receptacle must reading the remote control when a button is
not allow water into the pump thus causing be free of water, salt, calcium, magnesium and pressed and the red LED light flashes.
(Ground Fault Circuit Interrupter) be utilized dust. Failure to do so can 8. Make sure nothing is between the pump and
in the branch circuit supplying all water
permanent damage to the impeller, shaft and or CAUTION:
the pump. cause fire, damage to property, remote control that will effect remote control.
pump and aquarium electrical equipment. 1. A well built aquarium using thicker than normal
If you do not have a GFCI, please see your
• Do not plug into a power strip, Always plug the permanent damage to the
glass is required. Minimum thickness of 5/8in The maximum distance the pump can read
pump directly to a GFCI outlet using a drip loop. product and personal injury not the remote control is 2.5 ft.
local electrical supplier for this device. must be used for aquarium size: 48 x 18 x 24
• Seio Wave pump is designed to run completely limited to loss of life.
(in). The use of thinner glass or a poorly made 9. Pump will start with Standard mode once it
Important Warning and Safeguards submerged in water. Do not operate pump Do not plug into extension aquarium will result in leaks or panel separation. plugged in.
• Do not operate pump with Seio Wave pump outside of water! This pump should be cord/power strip. 2. The use of knock down stands is not 10. When changing water action, water flow will
without being fully submersed at all times. submerged in water before connecting to a recommended. Use a well built wood base. change irregularly. Allow 60 seconds for the
A drip loop must be used when
Not doing so can cause permanent damage power source. 3. For best performance, pump should be mode change.
plugging all electrical aquarium
to the pump. • Seio Wave pump may be utilized in either fresh devices. A drip loop is that part positioned in the center of the side of the 11. Improper water level may cause the pump
• Replace the impeller and or shaft if there is water or salt water but not in foreign fluids,
of the cord hanging below the aquarium and approximately 1/3 to 1/2 below to make noise. Use the flow control button
any excess signs of wear. flammable liquids or any chemical. the water level. to balance out the wave action.
receptacle.
• Prior to maintenance on any electrical The national code requires that
4. To avoid risk of leakage, the minimum water
aquarium appliance or maintenance to level must be 3.9 in (10cm) from the
the aquarium, you must disconnect all a GFCI (Ground fault circuit
5 6 7 aquarium’s top edge. 8 9
electrical aquarium devices. interrupter) be used in the
INSTALLATION 7. Verify the vacuum mounting bracket is secure.
1. Pump comes already assemebled. 8. Slide the pump onto the vacuum mounting
bracket and adjust to desired angle.
2. Choose a location for the pump that is a
minimum 2 in below the surface of the water. 9. Plug the pump directly to a GFCI outlet.
MAINTENANCE Clean well then verify that the impeller spins freely
on the shaft. Note: Replace impeller or ceramic
This warranty is void if the failure of the pump or
any part, sealant or component there of is due
arising out of the use of Seio™ Wave pump. Some states do not allow for the limitation or exclusion of
liability for incidental or consequential damages, so the above exclusion may not apply to you.
Preventing debris and free floating material shaft if any signs of excess wear on impeller or to (i) misuse, (ii) tampering, (iii) negligence, (iv)
from entering your Seio Wave pump is of shaft replace with a Seio Wave impeller kit. After misapplication, (v) abuse, (vi) accident and/or (vii) RETURNS
utmost importance to the longevity of your cleaning, reassemble impeller into the pump and failure to properly (a) maintain, (b) clean, (c) keep Please contact our service center at (805) 383-3566 ext. 102 or fax (805) 383-3565 to arrange repair and/or
pump. Your pump requires regular cleaning replace main strainer. pump fully submersed and/or use the pump with a replacement. Please allow 4-6 weeks for all returns.
to maintain a steady water flow. Note: Gravel, Ground Fault Circuit Interrupter (GFCI).
Impeller may need to be replaced periodically to
sand and calcium deposits will also diminish/
maintain a steady output flow. Seio Wave pump WARRANTY CARD
damage the longevity of Seio Wave pump and
replacement parts, are sold at your local pet CONSUMER REMEDIES Please go to our website, to download Warranty Card.
impeller. http://www.riopumps.com/Resources_folder/Warranty.html
dealer or call us, TAAM® for more information for TAAM®’s entire liability and your sole and exclusive
IMPORTANT purchasing Seio Wave pump replacement parts. remedy shall be either repair or replacement of Fill out this warranty card and mail it with PROOF OF PURCHASE within 15 days of purchase.
You must disconnect all electrical power to the Seio™ Wave pump only if you return the defective
aquarium and water pump before beginning Do not tamper with or replace the power cord
of this appliance. If the cord is damaged, the unit directly to TAAM® with the original receipt in
the maintenance on any electrical equipment
including Seio Wave pump. appliance should be discarded. its original box along with seven dollars ($7.00) for
shipping and handling. Do not send Seio™ Wave
AVAILABLE MODEL
Do not use any type of soap or detergent to LIMITED WARRANTY pump by insured mail. You may send your returns
Pump Size
Recommended
MINIMUM UPC No.
clean the Seio Wave pump and parts. Remove or replacements by UPS if requiring a signature Item No Flow Rate Aquarium Size for
TAAM® warrants that Seio™ Wave pump is free upon arrival. Any replaced unit will be warranted (approx.) Aquarium Length 0006760
main strainer. Clean and rinse of all dirt and WAVE EFFECT
from defects for a period of 6 months from the for the remaining time of the original warranty
debris. Remove the impeller and shaft and 5.5 x 2.8 x 3.3 in 36 x 18 x 24 in
initial date of purchase shown on the original period. In no event shall any shipping charges be SEIO W90 TBA 3 ft. (90 cm) 1038 9
clean well. Verify that the shaft spins freely on (14 x 7 x 8.3 cm) (90 x 45 x 60 cm)
cash register receipt. TAAM® disclaims all other reimbursed. In no event will TAAM® be liable for any
the shaft. In environments that have a high
warranties of merchantability and/or fitness for a consequential or incidental damages, including but 5.5 x 2.8 x 3.3 in 1580-3400 GPH 48 x 18 x 24 in
amount of calcium it may be necessary to SEIO W120 4 ft. (120 cm) 1039 6
particular purpose. Although this limited warranty not limited to, lost sea life, personal injury, (14 x 7 x 8.3 cm) (6000-13000 LPH) (120 x 45 x 60 cm)
clean impeller in 1 part vinegar 3 parts water
may give you specific rights, you may have other property damage, equipment damage, lostprofits,
solution, this will breakdown calcium build 60 x 24 x 30 in
rights that may vary from state to state. lost wages, lost savings, lost income, etc., SEIO W150 TBA TBA 5 ft. (150 cm) 1040 2