WELDING INSPECTION REPORT

Contractor : PT. EPITERMA MAS KONSTRUKSI Area : Cyanide Adsorption Tank - 011 Part of tank : Bottom
Client : PT. IMN Date :
Project : PROJECT MTPP66 Document No. : 001 /QC-WELD/EMK/III/2020
DWG No. : Page : 1 OF 1
Material Fit-Up Type of Welding Welder Stamp Visual Inspection
No. Joint No. Description WPS No. Welding Date Remarks
Spec. Heat No. Mill Certificate No Thickness Date Status Joint Process R/H F/C Date Status

Plate A36 Supply by IMN Supply by IMN 8


Butt
1 WP.06 BP 11/27/2019 Acc Weld SMAW 45/WPS/EMK/2018 12/8/2019 EMK-209 EMK-209 12/9/2019 Acc CRW
Plate A36 Supply by IMN Supply by IMN 8

Plate A36 Supply by IMN Supply by IMN 8


Butt
2 WP.11 BP Acc Weld
SMAW CRW
Plate A36 Supply by IMN Supply by IMN 8

Plate A36 Supply by IMN Supply by IMN 8


Butt
3 WP.10 BP Acc Weld
SMAW CRW
Plate A36 Supply by IMN Supply by IMN 8

Plate A36 Supply by IMN Supply by IMN 8


Butt
4 WP.02 BP Acc Weld
SMAW CRW
Plate A36 Supply by IMN Supply by IMN 8

Prepared by Examination / Witnessed / Reviewed by Witnessed / Reviewed by


PT. EMK PT. AR PT. INTERTEK Legend CRW
: ( Cut Re-Weld )

Name : Name : Name :


Date : Date : Date :
Photo Documentation Welding
TK-011

You might also like