0301-1018975
Sign of Inspector Contact Number of Inspector
05/19/2021
ection and Maintenance
05/19/2021
Site Report Summary
Need rectification as per the visual inspection No Rectification required now, as per site's
Amber Minor
recommendation. Yearly periodic check Required present condition.
Rectification Recommendation
Rating Significance
Type (specify action summary)
Need immediate rectification within 6 months
10 to 15 High Risk
based on Structural & Conditional Status
Detail observations:
5
Checklist
STATUS
SECT NO. DESCRIPTION (OK/ NOK) REMARKS PHOTO (ü)
4 Check all structural components are not broken or oxidized OK Satisfactory Condition
STRUCTURAL
5 Check that draining holes on pipe leg members, pipe lattice parts are not blocked. N/A
Check tower/structure’s verticality with the appropriate devices such as Plumb bob and
6 visial inspection. Any deviation must be reported with criticality. (can use separate sheet OK Visually OK
for observation/measurements)
Check the member sizing of the structural members. If no information available; take site
and member sizing measurement including the main legs/structure, bracing system,
7 platform, support, etc. Please produce a single drawings that are showing the member OK Refer elevation
sizing and details.
Check general site condition (standing water, drainage, etc.) and condition of the structural
1 supports or plumb. There must not be any water collection, cracking or splitting, chipped OK Satisfactory Condition P-002
or broken concrete.
BASE FOUNDATION & CONCRETE BLOCKS
Check the condition of aboveground concrete block parts. There must not be any stagnant no stagnant water
2 water. ok P-003
8 Check the condition of anchor setting in the concrete block /in the existing slab. ok Satisfactory Condition
Check the size and measurement of the foundation / concrete block. If no information
9 available; take site and measurement to produce a single drawings that are showing the OK Refer Layout Plan
details.
Check that the main structure and it’s connections are in the right position and all bolts are
1 adequately tightened and neither the connecting components are missing. For flat washer nok 70% of the bolts are Loose P-004
check the torque value performing bolt torque test in every panel.
CONNECTIONS
2
Check that no bolts or nuts or any bolting part like washers, pins, etc is missing. Replace
NOK
Antenna Mount Check nut
P-020
these immediately. missing
3 Check all bolts, nuts and bolting parts for corrosion. OK Satisfactory Condition P-005
4 Check the anchorage rod in the concrete. OK Satisfactory Condition P-003
Check for any misalignment of flange connection for the tubular tower legs/monopole
5
shafts.
NA NA
6 Make sure no visible cracks in welded connections. OK Satisfactory Condition
1 Check that each cable that is part of the guy wire is neither broken nor warped N/A
2 Check guy wires condition (corrosion, breaks, nicks, kinks, etc) N/A
3 Check for signs of corrosion and take remedial timely steps N/A
(FOR GUY WIRED TOWERS)
Check that the guy wire tightening system (TurnBuckle or equivalent) is properly greased
4 and in good condition N/A
Check for loose or missing fasteners and end fitting for cable connector (Thimbles, sleeves,
GUY WIRES
Ensure anchor head is clear of earth/moist (Corrosion control required if guy ancorage is in
6 N/A
direct contact with soil)
7 Check base for settlement, movement or earth cracks N/A
8 Check backfill heaped over concrete for water shedding N/A
9 Check anchor rod condition below earth N/A
Check and measure the tension of each guy wire using a strand dynamometer and
10 compare result with the installer's stated values. N/A
STATUS
SECT NO. DESCRIPTION (OK/ NOK) REMARKS PHOTO (ü)
Inspect that microwave dish, antenna, accessories and its supports are in good condition .
1
Check that fixing clamps are in good condition
OK Satisfactory Condition P-006
Satisfactory Condition
2 Inspect that coaxial cables/feeders cables/ cable connectors are in good condition OK P-006, P-007
ANTENNA & ACCESSORIES
Check the number of antenna and accessories to review the status of ownership and refer Antenna Data sheet
3 OK
tenancy for the colocation.
Check and report if there is any unused equipment or antenna or its’ parts have been left
4
installed
OK NOT FOUND ANY P-002
Check structural condition, azimuth and rigidity for all antennas, antenna supports and refer Antenna Data sheet
5 Ok
accessories (i.e coaxial cables, RRU, etc)
refer Antenna Data sheet
Identify and record dimensions, types, azimuth, leg definition and installation height of all
6 antennas currently on the structure and confirm that the loading does not exceed OK
structure design load. Use provided antenna datasheet.
Wash the structure and accessories with clean water once every six months to eliminate
SALTY ENV.
1 residue salt particles which may not be washed away by rain. N/A
Check the condition of structural members for corrosion, erosion and coating.
2 N/A
Check the climbing facilities, platforms, catwalks for safety and integrity. Report any
1 potential hazard. OK Satisfactory Condition P-007
2 Check rest and work platforms for missing component, defects, wear and tear. OK
3 Ensure that anti climb door can open and close. Clean and grease all hinges. ok Satisfactory Condition
Ensure the work platform's trap can open and close. Clean and grease all door
4 hinges. ok Satisfactory Condition
Check that access ladder is in good repair and condition; without any obstruction.
Check if there is enough space (minimum recommended access clearance of
5 600mm) and it must be safe for maneuvering and movement purposes. Check Ok Satisfactory Condition P-007
tower ladder for any signs of weakness, re-tighten all bolts
SAFETY COMPONENTS
Check the functioning of the fall arrestor system. Check if the climbing system is
6 properly installed, maintained and in good condition.
For a fall arrestor system with cable, check that the cable has not been over
7 tightened.
8 Check that the anti-climbing mechanical tool is functioning. N/A NOT FOUND ANY
9 Check if there is any safety, emergency and hazardous signs are provided OK Safety Signs provided P-008
Check all site security elements and components are existing, complete and in good
10 condition. (including fencing, locking system, etc). Please report if there is any OK Satisfactory Condition P-009
damage, malfunction or defects?
Address any safety concerns or hazards prior to proceeding especially with regards
11 to the access to our asset/site. No known safety hazards before service personnel OK
are allowed to access towers/structure.
Check if there is any unused, malfunction, faulty and defective items or structures Not found any
12 that can lead to any harm or site injuries or safety issues. Ok P-002
13 Check the positioning and installation of safety components. Ok Fire extinguisher present P-010
1 Check that all lightning and earthing components are existing and complete nok Lightening arrestor ring
P-011
including lightning arrestor, copper strip, and connection plate. clamp missing
4 Check the physical condition and installation of the copper strip ok Satisfactory Condition
Satisfactory Condition
Check the connection of the concrete block copper belting onto the copper strip the
5 connection of coaxial cables earthing onto the copper strip ok
Check the connection between the bottom coaxial cable earthing and the collection
6 copper bar fixed on the concrete block OK P-013
Satisfactory Condition
7 Check the tightening of the brass bolts of the lightning protection electrodes OK
STATUS
SECT NO. DESCRIPTION (OK/ NOK) REMARKS PHOTO (ü)
Check condition and well-functioning of components (Light bulb, energy cables, OB- Light fixed on
2 fixing parts, photoelectric cell, connections) NOK horizontal member. OB- P-015
Light clamp is missing
AVIATION SAFETY LIGHT
3 Check the functionality of controllers, flashers, alarms and photo control OK Satisfactory Condition
Check the condition of conduit, junction boxes, and fasteners weather tight and Junction Box Missing
6 secure NOK P-016
Check bulb condition - change all bulbs at the same time immediately before the Satisfactory Condition
7 rated service hours is achieved. OK
1 Inspect the paint condition of the structure (if applicable) OK Satisfactory Condition P-018
COATING AND ANTI CORROSION PROTECTION
5 For guyed masts, check for corrosion on the entire guy assembly. N/A
8 Check if there is any requirement for re-painting for coating. OK Satisfactory Condition P-018
Check if there is any requirement for replacement for any structural members
9 affected by the severe corrosion. (can attached in a separate sheet) N/A
Check the condition of the site surrounding, lawn and grass growing area. Have they
1 been properly maintained? OK Populated Area P-019
GENERAL SITE CONDITION
Do we have any unused wires, equipment’s parts or waste items scattered in our
2 boundary/area? ok not present P-002
3 Please check and report if there is any vandalism act and theft activities. OK NOT FOUND ANY
Please check and report if there is any malfunction, faulty and defective items
4 which have not been replaced. OK NOT FOUND ANY
Please address if there is any areas or aspects which related to the site condition
5 which require our attention for asset integrity, security or safety reasons. OK NOT FOUND ANY
Check and record any damage, broken, defect and malfunction item caused by the
1 severe weather condition (earthquake, typhoon, flood, etc) N/A
POST SEVERE WEATHER
(When applicable)
2 Check the status and condition of antenna mounting brackets NOK 70% of the bolts are Loose P-004
3 Check condition of the structural supports, connections, base and foundation. OK Satisfactory Condition P-003
4 Prepare a complete report to state the structural condition and record the incident. N/A
NOTE : PLEASE USE ADDITIONAL SHEETS OF PAPERS IF REQUIRED. THE CHECKER/S IS RECOMMENDED TO TAKE PHOTOS AS THEIR SUPPORTING DOCUMENTS FOR THEIR
RESULT FINDINGS/REPORTS.
No DG&Fuel Tank
Panaromic (0 degree)
P-001
P-003
P-005
P-007
P-009
P-011
P-013
P-015
P-017
P-019
P-021
Total Tower Face (Leg B-C)
GPS
Panaromic (30 degree)
P-002
P-004
P-006
P-008
P-010
P-012
P-014
P-016
P-018
P-020
P-014
Defect
EXTENT OF Qty To
NO ITEM / COMPONENT REMARKS PHOTO (ü)
DAMAGE Rectify
6 Junction Box Missing Junction Bo should be installed for OB- Light P-F
05/19/2021
PICTURES OF DEFECTS
P-I P-J
P-K P-L
P-M P-N
olts
p is missing
Missing
Antenna Data
ANTENNA DATA
Leg
A : North - East
B : South - East Antenna Size Antenna Area(m²) Antenna Type Feeder/Cables
Height from Antenna Owner Antenna Connectivity
No. C : South - West H(m) x W(m) x D(m) (GSM,RRU, ODU, Azimuth Manufacturer
Ground (m) Condition Operator (in-use or not in-use)
D : North - West or Diameter (m) MW Dish and etc.)
Note:
i) Mark Antenna here (GSM1, GSM2, MW1, MW3, RRU1 etc.) and mark the same antenna in picture report with same notation to validate.
ii) Leg A is defined to be closest leg to the measured geographic north, subsequently Leg B, Leg C and Leg D in clockwise direction.
iii) Use additional sheet of paper if required.
iv) Antenna Connectivity - Connected or Disconnected. All disconnected antenna need to be removed from the structure (off loading).
05/19/2021
TOWER Profile INFO
~ Sketch overall tower module and show True North, section height, Face width at top and bottom of section, member sizes & connection details.
~ For pipe members outside diameter and wall thickness, solid round diameter and angle size and thickness (60 or 90 degree)
~ Show platform (Type - Working or rest platform, Height from ground)
~ Check Next page for detail instruction as per EIA-TIA guide line
SITE LOCATION PLAN:-
05/19/2021