You are on page 1of 40

SHOP MICHESTHER ENGINEERING

Column Reinforcement Design Calc. By:


Rev: 1 Checked By:

Column Reinforcement Design


1C1 (A-2) (225/225)
(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 139.7, 144.1 -5.6, 3.5 2.9, -1.7
2 121.7, 126.0 -4.1, 2.6 3.1, -1.8
3 112.1, 116.5 -5.0, 3.1 1.8, -1.0
4 118.0, 121.7 -4.8, 3.1 1.0, 0.2
5 119.3, 123.0 -4.6, 2.9 3.9, -3.2
6 120.3, 124.0 -6.2, 4.7 2.5, -1.5

7 117.0, 120.7 -3.2, 1.3 2.5, -1.5

Critical Loading: 1 - (G*F)


min Design
N 144.1 - 144.1 kN
M11 -5.6 -1.6 -8.1 kN.m
M22 2.9 1.6 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.114
=
Beta = 0.86

Vd(1/2) = 0.3 / 3.2 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.82 / 0.92 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.07 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C1 (A-2) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 17.4, 21.7 -3.8, 6.2 1.4, -2.8
2 14.7, 19.1 -2.8, 4.6 1.3, -2.8
3 15.0, 19.3 -3.5, 5.6 1.1, -1.8
4 14.8, 18.5 -3.2, 5.3 1.0, -2.2
5 14.9, 18.6 -3.2, 5.2 1.4, -2.5
6 15.1, 18.9 -3.5, 5.5 1.2, -2.4

7 14.6, 18.3 -3.0, 5.1 1.2, -2.4

Critical Loading: 1 - (G*F)


min Design
N 21.7 - 21.7 kN
M11 6.2 0.2 8.9 kN.m
M22 -2.8 -0.2 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5
0.017

ProtaStructure v3.0.4 Page 1


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

N/bhFcu
=
Beta = 0.98

Vd(1/2) = 1.6 / 3.9 kN Short Column... As (Req): %0.44 224.20 mm2


vc'(1/2) = 0.77 / 0.79 N/mm2 Le1/b1 = 8.1 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.03 / 0.08 N/mm2 Le2/b2 = 8.1 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C2 (A-3) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 181.7, 186.1 -4.2, 2.7 -0.7, 0.5
2 141.0, 145.3 -2.7, 1.8 -1.5, 1.0
3 161.7, 166.0 -4.0, 2.6 0.4, -0.2
4 154.7, 158.4 -3.5, 2.3 -2.2, 2.2
5 153.7, 157.4 -3.5, 2.2 1.1, -1.4
6 155.8, 159.5 -5.0, 4.0 -0.6, 0.4

7 152.6, 156.3 -2.0, 0.5 -0.6, 0.4

Critical Loading: 1 - (G*F)


min Design
N 186.1 - 186.1 kN
M11 -4.2 -2.1 -5.9 kN.m
M22 -0.7 -2.1 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.147
=
Beta = 0.83

Vd(1/2) = 0.9 / 1.0 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.95 / 0.92 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.02 / 0.02 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C2 (A-3) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 17.9, 22.2 -3.0, 4.9 -0.3, 0.6
2 14.5, 18.9 -2.1, 3.3 -0.7, 1.4
3 16.2, 20.5 -2.8, 4.7 0.2, -0.4
4 15.3, 19.0 -2.5, 4.1 -0.5, 0.8
5 15.3, 19.0 -2.6, 4.1 0.0, 0.3
6 15.6, 19.3 -2.8, 4.4 -0.2, 0.5

7 15.0, 18.8 -2.3, 3.9 -0.3, 0.5

Critical Loading: 1 - (G*F)


min Design
N 22.2 - 22.2 kN

ProtaStructure v3.0.4 Page 2


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

M11 4.9 0.3 5.5 kN.m


M22 0.6 0.3 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.018
=
Beta = 0.98

Vd(1/2) = 0.8 / 3.1 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.77 / 0.79 N/mm2 Le1/b1 = 8.1 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.02 / 0.06 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C3 (A-4) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 171.4, 175.8 -4.2, 2.7 0.0, 0.1
2 131.8, 136.1 -2.7, 1.8 0.8, -0.4
3 153.7, 158.1 -4.1, 2.6 -0.9, 0.6
4 145.4, 149.1 -3.6, 2.3 -1.6, 1.8
5 145.5, 149.2 -3.5, 2.2 1.6, -1.7
6 147.1, 150.8 -5.1, 4.0 0.0, 0.0

7 143.8, 147.5 -2.0, 0.5 0.0, 0.1

Critical Loading: 1 - (G*F)


min Design
N 175.8 - 175.8 kN
M11 -4.2 -2.0 -5.9 kN.m
M22 0.1 2.0 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.139
=
Beta = 0.84

Vd(1/2) = 0.5 / 1.0 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.92 / 0.92 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.02 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C3 (A-4) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 20.1, 24.5 -3.1, 5.0 -0.1, 0.1
2 16.0, 20.4 -2.2, 3.4 0.2, -0.7
3 18.2, 22.6 -2.9, 4.8 -0.5, 0.9
4 17.2, 20.9 -2.6, 4.2 -0.4, 0.3
5 17.2, 20.9 -2.6, 4.2 0.1, -0.2
6 17.5, 21.2 -2.9, 4.4 -0.1, 0.1

ProtaStructure v3.0.4 Page 3


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

7 16.9, 20.6 -2.4, 4.0 -0.1, 0.1

Critical Loading: 3 - (G+Q *F1)


min Design
N 22.6 - 22.6 kN
M11 4.8 0.3 5.6 kN.m
M22 0.9 0.3 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.018
=
Beta = 0.98

Vd(1/2) = 0.4 / 3.2 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.77 / 0.79 N/mm2 Le1/b1 = 8.1 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.07 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C4 (A-5) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 175.2, 179.5 -4.3, 2.7 0.0, 0.0
2 136.0, 140.4 -2.8, 1.8 -0.8, 0.6
3 155.7, 160.0 -4.2, 2.6 0.9, -0.5
4 148.6, 152.3 -3.6, 2.3 -1.6, 1.8
5 148.6, 152.3 -3.6, 2.3 1.6, -1.8
6 150.2, 154.0 -5.1, 4.0 0.0, 0.0

7 147.0, 150.7 -2.1, 0.6 0.0, 0.0

Critical Loading: 1 - (G*F)


min Design
N 179.5 - 179.5 kN
M11 -4.3 -2.0 -6.0 kN.m
M22 0.0 2.0 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.142
=
Beta = 0.83

Vd(1/2) = 0.0 / 1.0 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.77 / 0.92 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.00 / 0.02 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C4 (A-5) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 17.5, 21.8 -3.1, 5.1 -0.2, 0.1

ProtaStructure v3.0.4 Page 4


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

2 13.9, 18.2 -2.2, 3.4 -0.6, 0.9


3 16.1, 20.5 -3.0, 4.9 0.2, -0.7
4 14.9, 18.7 -2.7, 4.3 -0.5, 0.4
5 15.0, 18.7 -2.7, 4.3 0.1, -0.1
6 15.2, 19.0 -2.9, 4.5 -0.2, 0.1
7 14.7, 18.4 -2.4, 4.1 -0.2, 0.1

Critical Loading: 3 - (G+Q *F1)


min Design
N 20.5 - 20.5 kN
M11 4.9 0.2 5.5 kN.m
M22 -0.7 -0.2 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.016
=
Beta = 0.98

Vd(1/2) = 0.6 / 3.2 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.77 / 0.79 N/mm2 Le1/b1 = 8.1 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.07 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C5 (A-6) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 130.4, 134.7 -3.2, 2.1 -1.5, 1.0
2 97.5, 101.9 -2.3, 1.5 -0.6, 0.4
3 122.9, 127.2 -3.1, 2.0 -1.8, 1.1
4 110.8, 114.6 -2.7, 1.7 -2.9, 2.6
5 111.2, 115.0 -2.7, 1.8 0.4, -1.0
6 112.6, 116.4 -4.2, 3.5 -1.2, 0.8

7 109.4, 113.2 -1.2, 0.0 -1.3, 0.8

Critical Loading: 1 - (G*F)


min Design
N 134.7 - 134.7 kN
M11 -3.2 -1.5 -4.5 kN.m
M22 -1.5 -1.5 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.106
=
Beta = 0.87

Vd(1/2) = 0.5 / 0.5 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.88 / 0.86 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.01 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C5 (A-6) (225/225)


ProtaStructure v3.0.4 Page 5
SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

(C25 / Grade 380 (Type 2))


NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 16.5, 20.8 -2.2, 3.7 -0.9, 1.5
2 13.3, 17.6 -1.7, 2.7 -0.5, 0.7
3 14.9, 19.2 -2.0, 3.5 -1.0, 1.8
4 14.1, 17.8 -1.9, 3.2 -1.0, 1.5
5 14.1, 17.8 -1.8, 3.1 -0.5, 1.0
6 14.4, 18.1 -2.1, 3.4 -0.8, 1.3
7 13.8, 17.5 -1.6, 3.0 -0.8, 1.3

Critical Loading: 3 - (G+Q *F1)


min Design
N 19.2 - 19.2 kN
M11 3.5 0.2 5.2 kN.m
M22 1.8 0.2 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.015
=
Beta = 0.98

Vd(1/2) = 1.1 / 2.3 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.77 / 0.79 N/mm2 Le1/b1 = 8.1 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.02 / 0.05 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C6 (A-7) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 130.5, 134.8 -3.2, 2.1 1.3, -0.7
2 97.6, 102.0 -2.3, 1.5 0.4, -0.2
3 122.9, 127.3 -3.1, 2.0 1.7, -1.0
4 111.3, 115.1 -2.7, 1.8 -0.5, 1.2
5 110.9, 114.6 -2.7, 1.8 2.7, -2.4
6 112.7, 116.5 -4.2, 3.5 1.1, -0.6

7 109.5, 113.2 -1.2, 0.0 1.1, -0.6

Critical Loading: 1 - (G*F)


min Design
N 134.8 - 134.8 kN
M11 -3.2 -1.5 -4.5 kN.m
M22 1.3 1.5 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.107
=
Beta = 0.87

Vd(1/2) = 0.2 / 0.5 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.87 / 0.86 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.00 / 0.01 N/mm2 Le2/b2 = 8.6 < 15.0 √

ProtaStructure v3.0.4 Page 6


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

Madd(1/2) = 0.0 / 0.0 kN.m 4Y16


Links = Y10-175

2C6 (A-7) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 16.4, 20.8 -2.2, 3.7 0.7, -1.3
2 13.3, 17.6 -1.7, 2.7 0.3, -0.4
3 14.8, 19.2 -2.0, 3.5 0.8, -1.6
4 14.0, 17.7 -1.8, 3.1 0.3, -0.8
5 14.1, 17.8 -1.9, 3.2 0.8, -1.3
6 14.3, 18.0 -2.1, 3.3 0.6, -1.1

7 13.8, 17.5 -1.6, 3.0 0.5, -1.1

Critical Loading: 3 - (G+Q *F1)


min Design
N 19.2 - 19.2 kN
M11 3.5 0.2 5.1 kN.m
M22 -1.6 -0.2 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.015
=
Beta = 0.98

Vd(1/2) = 0.9 / 2.3 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.77 / 0.79 N/mm2 Le1/b1 = 8.1 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.02 / 0.05 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C7 (A-8) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 175.1, 179.4 -4.3, 2.7 -0.2, 0.2
2 135.9, 140.3 -2.8, 1.8 0.6, -0.3
3 155.6, 160.0 -4.2, 2.6 -1.0, 0.6
4 148.6, 152.3 -3.6, 2.3 -1.8, 2.0
5 148.5, 152.2 -3.6, 2.3 1.4, -1.6
6 150.2, 153.9 -5.1, 4.1 -0.2, 0.2

7 146.9, 150.6 -2.1, 0.6 -0.2, 0.2

Critical Loading: 1 - (G*F)


min Design
N 179.4 - 179.4 kN
M11 -4.3 -2.0 -6.0 kN.m
M22 -0.2 -2.0 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

ProtaStructure v3.0.4 Page 7


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

N/bhFcu 0.142
=
Beta = 0.83

Vd(1/2) = 0.4 / 1.0 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.93 / 0.92 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.02 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C7 (A-8) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 17.8, 22.1 -3.1, 5.1 0.0, 0.1
2 14.1, 18.5 -2.2, 3.4 0.3, -0.6
3 16.4, 20.7 -3.0, 4.9 -0.3, 0.8
4 15.2, 19.0 -2.7, 4.3 -0.2, 0.4
5 15.2, 18.9 -2.7, 4.3 0.3, -0.1
6 15.5, 19.2 -2.9, 4.5 0.0, 0.1

7 15.0, 18.7 -2.4, 4.1 0.0, 0.1

Critical Loading: 3 - (G+Q *F1)


min Design
N 20.7 - 20.7 kN
M11 4.9 0.2 5.7 kN.m
M22 0.8 0.2 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.016
=
Beta = 0.98

Vd(1/2) = 0.0 / 3.2 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.76 / 0.79 N/mm2 Le1/b1 = 8.1 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.00 / 0.07 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C8 (A-9) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 172.6, 176.9 -4.2, 2.7 -0.1, 0.1
2 132.9, 137.3 -2.7, 1.8 -0.9, 0.6
3 154.5, 158.8 -4.1, 2.6 0.8, -0.5
4 146.4, 150.1 -3.5, 2.2 -1.7, 1.9
5 146.4, 150.2 -3.6, 2.3 1.6, -1.7
6 148.1, 151.8 -5.1, 4.0 0.0, 0.1

7 144.8, 148.5 -2.0, 0.5 -0.1, 0.1

Critical Loading: 1 - (G*F)


min Design

ProtaStructure v3.0.4 Page 8


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

N 176.9 - 176.9 kN
M11 -4.2 -2.0 -5.9 kN.m
M22 0.1 2.0 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.140
=
Beta = 0.84

Vd(1/2) = 0.6 / 1.0 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.94 / 0.92 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.02 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C8 (A-9) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 19.2, 23.5 -3.1, 5.0 -0.2, 0.1
2 15.3, 19.7 -2.2, 3.4 -0.5, 0.9
3 17.3, 21.7 -2.9, 4.8 0.3, -0.7
4 16.4, 20.1 -2.6, 4.2 -0.4, 0.4
5 16.4, 20.1 -2.6, 4.2 0.1, -0.2
6 16.6, 20.4 -2.9, 4.4 -0.1, 0.1

7 16.1, 19.8 -2.4, 4.0 -0.1, 0.1

Critical Loading: 3 - (G+Q *F1)


min Design
N 21.7 - 21.7 kN
M11 4.8 0.2 5.5 kN.m
M22 -0.7 -0.2 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.017
=
Beta = 0.98

Vd(1/2) = 0.6 / 3.2 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.77 / 0.79 N/mm2 Le1/b1 = 8.1 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.07 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C9 (A-10) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 172.0, 176.4 -4.2, 2.7 -0.2, 0.2
2 132.6, 137.0 -2.7, 1.8 0.7, -0.4
3 153.9, 158.3 -4.1, 2.6 -1.0, 0.6
4 146.0, 149.7 -3.5, 2.2 -1.7, 1.9
5 145.9, 149.7 -3.6, 2.3 1.5, -1.7

ProtaStructure v3.0.4 Page 9


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

6 147.6, 151.3 -5.1, 4.0 -0.1, 0.1


7 144.3, 148.0 -2.0, 0.5 -0.2, 0.1

Critical Loading: 1 - (G*F)


min Design
N 176.4 - 176.4 kN
M11 -4.2 -2.0 -5.9 kN.m
M22 -0.2 -2.0 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.139
=
Beta = 0.84

Vd(1/2) = 0.4 / 1.0 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.92 / 0.91 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.02 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C9 (A-10) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 19.8, 24.1 -3.1, 5.0 0.0, 0.1
2 15.8, 20.1 -2.2, 3.4 0.3, -0.7
3 17.9, 22.2 -2.9, 4.8 -0.3, 0.9
4 16.8, 20.6 -2.6, 4.2 -0.3, 0.3
5 16.9, 20.6 -2.6, 4.2 0.3, -0.2
6 17.2, 20.9 -2.9, 4.4 0.0, 0.1

7 16.6, 20.3 -2.4, 4.0 0.0, 0.1

Critical Loading: 3 - (G+Q *F1)


min Design
N 22.2 - 22.2 kN
M11 4.8 0.2 5.7 kN.m
M22 0.9 0.2 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.018
=
Beta = 0.98

Vd(1/2) = 0.5 / 3.2 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.77 / 0.79 N/mm2 Le1/b1 = 8.1 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.07 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C10 (A-11) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)

ProtaStructure v3.0.4 Page 10


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

1 180.3, 184.6 -4.2, 2.7 0.3, -0.2


2 139.6, 144.0 -2.8, 1.8 -0.6, 0.4
3 160.6, 165.0 -4.1, 2.6 1.2, -0.7
4 152.5, 156.2 -3.5, 2.2 -1.3, 1.7
5 153.4, 157.2 -3.6, 2.4 1.9, -1.9
6 154.6, 158.3 -5.1, 4.0 0.3, -0.1
7 151.3, 155.0 -2.0, 0.5 0.3, -0.1

Critical Loading: 1 - (G*F)


min Design
N 184.6 - 184.6 kN
M11 -4.2 -2.1 -6.0 kN.m
M22 0.3 2.1 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.146
=
Beta = 0.83

Vd(1/2) = 0.2 / 1.0 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.94 / 0.92 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.00 / 0.02 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C10 (A-11) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 17.3, 21.7 -3.1, 5.0 -0.2, -0.2
2 13.8, 18.1 -2.1, 3.3 -0.5, 0.7
3 15.9, 20.3 -2.9, 4.8 0.3, -1.0
4 14.8, 18.5 -2.6, 4.2 -0.4, 0.1
5 14.8, 18.5 -2.6, 4.2 0.1, -0.4
6 15.1, 18.8 -2.9, 4.4 -0.1, -0.1

7 14.5, 18.3 -2.3, 4.0 -0.1, -0.1

Critical Loading: 3 - (G+Q *F1)


min Design
N 20.3 - 20.3 kN
M11 4.8 0.2 5.7 kN.m
M22 -1.0 -0.2 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.016
=
Beta = 0.98

Vd(1/2) = 0.0 / 3.2 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.74 / 0.79 N/mm2 Le1/b1 = 8.1 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.00 / 0.07 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

ProtaStructure v3.0.4 Page 11


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

1C11 (A-12) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 99.4, 103.8 -3.4, 2.2 -3.4, 2.1
2 67.8, 72.1 -2.5, 1.6 -2.1, 1.3
3 99.7, 104.1 -3.2, 2.1 -3.5, 2.2
4 85.8, 89.5 -2.8, 1.8 -4.3, 3.5
5 83.3, 87.0 -3.0, 2.0 -1.4, 0.1
6 86.1, 89.9 -4.4, 3.6 -2.8, 1.8

7 82.9, 86.7 -1.4, 0.1 -2.8, 1.8

Critical Loading: 1 - (G*F)


min Design
N 103.8 - 103.8 kN
M11 -3.4 -1.2 -6.5 kN.m
M22 -3.4 -1.2 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.082
=
Beta = 0.90

Vd(1/2) = 0.6 / 1.6 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.82 / 0.86 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.03 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C11 (A-12) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 13.6, 17.9 -2.5, 4.0 -2.0, 3.4
2 10.3, 14.6 -1.9, 2.9 -1.5, 2.2
3 12.9, 17.2 -2.2, 3.7 -1.9, 3.5
4 11.7, 15.4 -2.1, 3.4 -1.9, 3.0
5 11.5, 15.2 -2.1, 3.4 -1.5, 2.8
6 11.9, 15.6 -2.4, 3.6 -1.7, 2.9

7 11.3, 15.1 -1.9, 3.2 -1.7, 2.9

Critical Loading: 1 - (G*F)


min Design
N 17.9 - 17.9 kN
M11 4.0 0.2 7.4 kN.m
M22 3.4 0.2 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.014
=

ProtaStructure v3.0.4 Page 12


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

Beta = 0.98

Vd(1/2) = 2.1 / 2.5 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.77 / 0.78 N/mm2 Le1/b1 = 8.1 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.04 / 0.05 N/mm2 Le2/b2 = 8.1 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C12 (B-1) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 95.6, 99.9 -1.9, 1.3 4.9, -3.0
2 83.8, 88.1 -1.4, 0.9 4.7, -2.8
3 77.6, 81.9 -1.8, 1.2 3.5, -2.1
4 80.6, 84.3 -1.7, 1.2 2.8, -0.9
5 82.0, 85.7 -1.5, 1.0 5.6, -4.2
6 83.3, 87.0 -3.1, 2.8 4.2, -2.5

7 79.3, 83.0 -0.1, -0.6 4.2, -2.5

Critical Loading: 1 - (G*F)


min Design
N 99.9 - 99.9 kN
M11 -1.9 -1.1 0.0 kN.m
M22 4.9 1.1 6.6 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.079
=
Beta = 0.91

Vd(1/2) = 3.8 / 0.2 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.87 / 0.82 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.08 / 0.00 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C12 (B-1) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 12.6, 16.9 -1.6, 2.4 2.3, -4.6
2 11.0, 15.3 -1.2, 1.8 2.1, -4.3
3 10.6, 14.9 -1.4, 2.2 1.7, -3.3
4 10.7, 14.4 -1.3, 2.0 1.8, -3.8
5 10.8, 14.5 -1.4, 2.0 2.1, -4.0
6 11.1, 14.8 -1.6, 2.2 1.9, -3.9

7 10.4, 14.1 -1.1, 1.8 1.9, -3.9

Critical Loading: 1 - (G*F)


min Design
N 16.9 - 16.9 kN
M11 2.4 0.2 0.0 kN.m
M22 -4.6 -0.2 -7.0 kN.m

ProtaStructure v3.0.4 Page 13


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.013
=
Beta = 0.98

Vd(1/2) = 2.7 / 1.5 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.76 / 0.78 N/mm2 Le1/b1 = 8.1 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.06 / 0.03 N/mm2 Le2/b2 = 8.1 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C13 (C-1) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 103.1, 107.5 1.1, -0.5 3.0, -1.8
2 91.4, 95.8 0.6, -0.3 3.1, -1.8
3 82.1, 86.4 1.1, -0.6 1.8, -1.1
4 86.3, 90.1 0.8, -0.4 1.0, 0.2
5 89.0, 92.7 1.0, -0.5 4.0, -3.2
6 88.5, 92.2 -0.7, 1.3 2.5, -1.5

7 86.8, 90.6 2.5, -2.3 2.5, -1.5

Critical Loading: 1 - (G*F)


min Design
N 107.5 - 107.5 kN
M11 1.1 1.2 0.0 kN.m
M22 3.0 1.2 4.1 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.085
=
Beta = 0.90

Vd(1/2) = 0.3 / 0.7 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.80 / 0.87 N/mm2 Le1/b1 = 8.5 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.01 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C13 (C-1) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 4.3, 8.6 0.5, -0.8 1.9, -3.2
2 4.3, 8.7 0.3, -0.5 1.7, -3.1
3 3.5, 7.8 0.5, -0.9 1.4, -2.1
4 3.6, 7.3 0.4, -0.7 1.4, -2.5
5 3.8, 7.5 0.4, -0.7 1.8, -2.8
6 3.6, 7.3 0.2, -0.4 1.6, -2.7

ProtaStructure v3.0.4 Page 14


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

7 3.8, 7.6 0.7, -1.0 1.6, -2.7

Critical Loading: 1 - (G*F)


min Design
N 8.6 - 8.6 kN
M11 -0.8 -0.1 0.0 kN.m
M22 -3.2 -0.1 -4.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.007
=
Beta = 0.99

Vd(1/2) = 2.0 / 0.7 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.75 / 0.77 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.04 / 0.01 N/mm2 Le2/b2 = 8.1 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C14 (C-2) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 209.4, 213.7 3.0, -1.7 -0.1, 0.1
2 165.5, 169.9 2.0, -1.1 -1.1, 0.7
3 181.1, 185.5 2.8, -1.6 0.8, -0.5
4 178.1, 181.8 2.5, -1.4 -1.7, 1.9
5 176.7, 180.4 2.6, -1.5 1.5, -1.7
6 178.5, 182.2 0.9, 0.4 -0.1, 0.1

7 176.2, 180.0 4.1, -3.2 -0.1, 0.1

Critical Loading: 1 - (G*F)


min Design
N 213.7 - 213.7 kN
M11 3.0 2.4 4.9 kN.m
M22 -0.1 -2.4 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.169
=
Beta = 0.80

Vd(1/2) = 0.7 / 0.2 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.99 / 0.85 N/mm2 Le1/b1 = 8.5 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.00 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C14 (C-2) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 -0.9, 3.4 1.9, -2.9 0.2, -0.1

ProtaStructure v3.0.4 Page 15


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

2 1.3, 5.6 1.4, -2.1 -0.2, 0.8


3 -1.2, 3.2 1.7, -2.7 0.6, -0.9
4 -0.6, 3.1 1.6, -2.5 -0.1, 0.2
5 -0.5, 3.2 1.6, -2.5 0.5, -0.3
6 -0.7, 3.1 1.3, -2.2 0.2, -0.1
7 -0.5, 3.3 1.9, -2.8 0.2, -0.1

Critical Loading: 3 - (G+Q *F1)


min Design
N 3.2 - 3.2 kN
M11 -2.7 0.0 -3.7 kN.m
M22 -0.9 0.0 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.003
=
Beta = 1.00

Vd(1/2) = 0.6 / 1.9 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.74 / 0.76 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.04 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C15 (C-3) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 204.3, 208.6 2.8, -1.6 -0.1, 0.1
2 158.6, 162.9 1.7, -1.0 0.8, -0.5
3 178.9, 183.3 2.8, -1.7 -1.0, 0.6
4 173.0, 176.7 2.3, -1.3 -1.7, 1.9
5 172.9, 176.7 2.4, -1.4 1.5, -1.7
6 174.1, 177.8 0.7, 0.4 -0.1, 0.1

7 171.8, 175.5 4.0, -3.2 -0.1, 0.1

Critical Loading: 1 - (G*F)


min Design
N 208.6 - 208.6 kN
M11 2.8 2.3 4.7 kN.m
M22 0.1 2.3 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.165
=
Beta = 0.81

Vd(1/2) = 0.5 / 0.1 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.96 / 0.82 N/mm2 Le1/b1 = 8.5 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.00 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C15 (C-3) (225/225)


ProtaStructure v3.0.4 Page 16
SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

(C25 / Grade 380 (Type 2))


NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 3.3, 7.7 1.7, -2.6 -0.2, 0.2
2 4.5, 8.9 1.1, -1.6 0.2, -0.7
3 2.6, 6.9 1.7, -2.6 -0.6, 1.0
4 3.1, 6.8 1.4, -2.2 -0.5, 0.4
5 3.0, 6.7 1.4, -2.2 0.1, -0.1
6 3.0, 6.7 1.2, -1.9 -0.2, 0.2
7 3.1, 6.9 1.7, -2.5 -0.2, 0.2

Critical Loading: 3 - (G+Q *F1)


min Design
N 6.9 - 6.9 kN
M11 -2.6 -0.1 -3.6 kN.m
M22 1.0 0.1 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.005
=
Beta = 0.99

Vd(1/2) = 0.6 / 1.7 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.75 / 0.77 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.04 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C16 (C-4) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 201.9, 206.3 2.8, -1.6 -0.2, 0.2
2 156.1, 160.5 1.7, -0.9 -1.1, 0.8
3 177.5, 181.8 2.8, -1.6 0.8, -0.5
4 171.0, 174.7 2.3, -1.3 -1.7, 1.9
5 170.9, 174.6 2.4, -1.4 1.4, -1.6
6 172.1, 175.8 0.7, 0.5 -0.2, 0.1

7 169.8, 173.5 4.0, -3.2 -0.2, 0.1

Critical Loading: 1 - (G*F)


min Design
N 206.3 - 206.3 kN
M11 2.8 2.3 4.6 kN.m
M22 -0.2 -2.3 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.163
=
Beta = 0.81

Vd(1/2) = 0.7 / 0.1 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.97 / 0.81 N/mm2 Le1/b1 = 8.5 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.02 / 0.00 N/mm2 Le2/b2 = 8.6 < 15.0 √

ProtaStructure v3.0.4 Page 17


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

Madd(1/2) = 0.0 / 0.0 kN.m 4Y16


Links = Y10-175

2C16 (C-4) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 3.3, 7.7 1.6, -2.5 0.0, 0.1
2 4.5, 8.8 1.0, -1.5 -0.4, 1.0
3 2.6, 6.9 1.6, -2.5 0.4, -0.8
4 3.0, 6.7 1.4, -2.1 -0.3, 0.4
5 3.1, 6.8 1.4, -2.1 0.3, -0.2
6 2.9, 6.6 1.1, -1.8 0.0, 0.1

7 3.1, 6.8 1.6, -2.4 0.0, 0.1

Critical Loading: 3 - (G+Q *F1)


min Design
N 6.9 - 6.9 kN
M11 -2.5 -0.1 -3.3 kN.m
M22 -0.8 -0.1 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.005
=
Beta = 0.99

Vd(1/2) = 0.5 / 1.6 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.75 / 0.77 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.03 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C17 (C-5) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 210.7, 215.0 2.8, -1.6 0.4, -0.2
2 163.5, 167.9 1.8, -1.0 1.3, -0.7
3 184.4, 188.8 2.8, -1.7 -0.6, 0.4
4 178.0, 181.7 2.4, -1.4 -1.3, 1.6
5 178.7, 182.4 2.4, -1.4 1.9, -2.0
6 179.5, 183.2 0.7, 0.4 0.3, -0.2

7 177.2, 180.9 4.0, -3.2 0.3, -0.2

Critical Loading: 1 - (G*F)


min Design
N 215.0 - 215.0 kN
M11 2.8 2.4 4.8 kN.m
M22 0.4 2.4 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

ProtaStructure v3.0.4 Page 18


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

N/bhFcu 0.170
=
Beta = 0.80

Vd(1/2) = 0.8 / 0.1 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.97 / 0.82 N/mm2 Le1/b1 = 8.5 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.02 / 0.00 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C17 (C-5) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 0.3, 4.6 1.7, -2.6 -0.1, -0.2
2 2.2, 6.6 1.1, -1.6 0.3, -1.1
3 0.0, 4.3 1.7, -2.6 -0.5, 0.7
4 0.5, 4.2 1.4, -2.2 -0.4, 0.1
5 0.4, 4.2 1.5, -2.2 0.2, -0.5
6 0.4, 4.1 1.2, -1.9 -0.1, -0.2

7 0.6, 4.3 1.7, -2.5 -0.1, -0.2

Critical Loading: 3 - (G+Q *F1)


min Design
N 4.3 - 4.3 kN
M11 -2.6 0.0 -3.4 kN.m
M22 0.7 0.0 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.003
=
Beta = 1.00

Vd(1/2) = 0.5 / 1.7 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.74 / 0.76 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.04 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C18 (C-6) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 129.0, 133.4 2.0, -1.1 -3.5, 2.2
2 109.2, 113.6 1.3, -0.7 -3.7, 2.3
3 107.0, 111.3 2.1, -1.2 -2.1, 1.3
4 110.5, 114.3 1.7, -1.0 -4.5, 3.6
5 108.6, 112.3 1.7, -0.9 -1.5, 0.2
6 110.8, 114.5 0.1, 0.9 -3.0, 1.9

7 108.4, 112.1 3.3, -2.8 -3.0, 1.9

Critical Loading: 1 - (G*F)


min Design

ProtaStructure v3.0.4 Page 19


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

N 133.4 - 133.4 kN
M11 2.0 1.5 0.0 kN.m
M22 -3.5 -1.5 -5.3 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.105
=
Beta = 0.87

Vd(1/2) = 0.6 / 0.3 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.85 / 0.85 N/mm2 Le1/b1 = 8.5 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.01 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C18 (C-6) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 5.3, 9.7 1.1, -1.7 -2.0, 3.5
2 5.1, 9.5 0.7, -1.1 -1.9, 3.6
3 4.7, 9.0 1.1, -1.8 -1.4, 2.2
4 4.6, 8.3 0.9, -1.5 -1.9, 3.1
5 4.6, 8.4 0.9, -1.5 -1.5, 2.9
6 4.5, 8.2 0.6, -1.2 -1.7, 3.0

7 4.7, 8.5 1.2, -1.8 -1.7, 3.0

Critical Loading: 1 - (G*F)


min Design
N 9.7 - 9.7 kN
M11 -1.7 -0.1 0.0 kN.m
M22 3.5 0.1 5.3 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.008
=
Beta = 0.99

Vd(1/2) = 2.2 / 1.2 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.75 / 0.77 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.05 / 0.02 N/mm2 Le2/b2 = 8.1 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C19 (C-7) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 128.8, 133.2 2.0, -1.1 3.4, -2.0
2 109.0, 113.4 1.2, -0.7 3.5, -2.1
3 106.8, 111.2 2.1, -1.2 2.0, -1.2
4 108.5, 112.2 1.7, -0.9 1.3, 0.0
5 110.4, 114.1 1.7, -1.0 4.3, -3.4

ProtaStructure v3.0.4 Page 20


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

6 110.6, 114.3 0.1, 0.9 2.8, -1.7


7 108.2, 111.9 3.3, -2.8 2.8, -1.7

Critical Loading: 1 - (G*F)


min Design
N 133.2 - 133.2 kN
M11 2.0 1.5 0.0 kN.m
M22 3.4 1.5 5.1 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.105
=
Beta = 0.87

Vd(1/2) = 0.5 / 0.3 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.84 / 0.85 N/mm2 Le1/b1 = 8.5 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.01 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C19 (C-7) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 5.3, 9.6 1.1, -1.7 1.9, -3.4
2 5.1, 9.4 0.7, -1.1 1.8, -3.4
3 4.6, 8.9 1.1, -1.8 1.3, -2.1
4 4.6, 8.3 0.9, -1.5 1.4, -2.7
5 4.6, 8.3 0.9, -1.5 1.8, -3.0
6 4.5, 8.2 0.6, -1.2 1.6, -2.9

7 4.7, 8.4 1.2, -1.8 1.6, -2.9

Critical Loading: 1 - (G*F)


min Design
N 9.6 - 9.6 kN
M11 -1.7 -0.1 0.0 kN.m
M22 -3.4 -0.1 -5.2 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.008
=
Beta = 0.99

Vd(1/2) = 2.1 / 1.2 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.75 / 0.77 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.04 / 0.02 N/mm2 Le2/b2 = 8.1 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C20 (C-8) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)

ProtaStructure v3.0.4 Page 21


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

1 210.7, 215.1 2.8, -1.6 -0.6, 0.4


2 163.6, 167.9 1.7, -1.0 -1.5, 1.0
3 184.5, 188.8 2.8, -1.7 0.5, -0.3
4 178.8, 182.5 2.4, -1.4 -2.1, 2.1
5 178.0, 181.8 2.4, -1.4 1.1, -1.4
6 179.6, 183.3 0.7, 0.5 -0.5, 0.3
7 177.2, 181.0 4.0, -3.2 -0.5, 0.3

Critical Loading: 1 - (G*F)


min Design
N 215.1 - 215.1 kN
M11 2.8 2.4 4.8 kN.m
M22 -0.6 -2.4 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.170
=
Beta = 0.80

Vd(1/2) = 1.0 / 0.1 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.98 / 0.82 N/mm2 Le1/b1 = 8.5 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.02 / 0.00 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C20 (C-8) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 0.3, 4.7 1.7, -2.6 0.0, 0.4
2 2.3, 6.6 1.1, -1.6 -0.4, 1.2
3 0.0, 4.4 1.7, -2.6 0.4, -0.6
4 0.5, 4.2 1.5, -2.2 -0.3, 0.6
5 0.6, 4.3 1.4, -2.2 0.3, 0.0
6 0.4, 4.1 1.2, -1.9 0.0, 0.3

7 0.6, 4.3 1.7, -2.5 0.0, 0.3

Critical Loading: 3 - (G+Q *F1)


min Design
N 4.4 - 4.4 kN
M11 -2.6 0.0 -3.2 kN.m
M22 -0.6 0.0 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.003
=
Beta = 1.00

Vd(1/2) = 0.4 / 1.7 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.74 / 0.76 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.04 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

ProtaStructure v3.0.4 Page 22


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

1C21 (C-9) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 202.2, 206.5 2.8, -1.6 0.0, 0.0
2 156.4, 160.8 1.7, -0.9 1.0, -0.5
3 177.6, 181.9 2.8, -1.6 -0.9, 0.6
4 171.1, 174.8 2.4, -1.4 -1.6, 1.8
5 171.2, 175.0 2.3, -1.3 1.6, -1.7
6 172.3, 176.0 0.7, 0.5 0.0, 0.0

7 170.0, 173.7 4.0, -3.2 0.0, 0.0

Critical Loading: 1 - (G*F)


min Design
N 206.5 - 206.5 kN
M11 2.8 2.3 4.6 kN.m
M22 0.0 2.3 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.163
=
Beta = 0.81

Vd(1/2) = 0.0 / 0.1 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.89 / 0.80 N/mm2 Le1/b1 = 8.5 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.00 / 0.00 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C21 (C-9) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 3.2, 7.6 1.6, -2.5 -0.1, 0.0
2 4.4, 8.8 1.0, -1.5 0.3, -0.8
3 2.5, 6.8 1.6, -2.5 -0.5, 0.9
4 3.0, 6.7 1.4, -2.1 -0.4, 0.3
5 2.9, 6.6 1.4, -2.1 0.2, -0.2
6 2.8, 6.6 1.1, -1.8 -0.1, 0.0

7 3.0, 6.8 1.6, -2.4 -0.1, 0.0

Critical Loading: 3 - (G+Q *F1)


min Design
N 6.8 - 6.8 kN
M11 -2.5 -0.1 -3.4 kN.m
M22 0.9 0.1 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.005
=

ProtaStructure v3.0.4 Page 23


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

Beta = 0.99

Vd(1/2) = 0.6 / 1.6 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.75 / 0.77 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.03 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C22 (C-10) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 202.3, 206.6 2.8, -1.6 -0.2, 0.2
2 156.5, 160.8 1.7, -0.9 -1.2, 0.8
3 177.7, 182.0 2.8, -1.6 0.8, -0.5
4 171.3, 175.0 2.4, -1.4 -1.8, 1.9
5 171.2, 174.9 2.3, -1.3 1.4, -1.6
6 172.4, 176.1 0.7, 0.5 -0.2, 0.1

7 170.1, 173.8 4.0, -3.2 -0.2, 0.1

Critical Loading: 1 - (G*F)


min Design
N 206.6 - 206.6 kN
M11 2.8 2.3 4.7 kN.m
M22 -0.2 -2.3 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.163
=
Beta = 0.81

Vd(1/2) = 0.7 / 0.1 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.97 / 0.80 N/mm2 Le1/b1 = 8.5 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.02 / 0.00 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C22 (C-10) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 3.3, 7.6 1.6, -2.5 0.0, 0.1
2 4.5, 8.8 1.0, -1.5 -0.4, 0.9
3 2.5, 6.9 1.6, -2.5 0.4, -0.8
4 3.0, 6.7 1.4, -2.1 -0.2, 0.3
5 3.0, 6.7 1.4, -2.1 0.3, -0.2
6 2.9, 6.6 1.1, -1.8 0.0, 0.1

7 3.1, 6.8 1.6, -2.4 0.0, 0.1

Critical Loading: 3 - (G+Q *F1)


min Design
N 6.9 - 6.9 kN
M11 -2.5 -0.1 -3.4 kN.m
M22 -0.8 -0.1 0.0 kN.m

ProtaStructure v3.0.4 Page 24


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.005
=
Beta = 0.99

Vd(1/2) = 0.5 / 1.6 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.75 / 0.77 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.03 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C23 (C-11) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 211.1, 215.5 2.8, -1.6 0.4, -0.2
2 163.9, 168.2 1.8, -1.0 1.3, -0.7
3 184.8, 189.2 2.8, -1.7 -0.6, 0.4
4 178.3, 182.0 2.4, -1.4 -1.3, 1.6
5 179.2, 183.0 2.3, -1.3 1.9, -1.9
6 179.9, 183.6 0.7, 0.5 0.3, -0.2

7 177.6, 181.3 4.0, -3.2 0.3, -0.2

Critical Loading: 1 - (G*F)


min Design
N 215.5 - 215.5 kN
M11 2.8 2.4 4.8 kN.m
M22 0.4 2.4 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.170
=
Beta = 0.80

Vd(1/2) = 0.8 / 0.1 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.97 / 0.82 N/mm2 Le1/b1 = 8.5 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.02 / 0.00 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C23 (C-11) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 0.5, 4.8 1.7, -2.6 -0.1, -0.2
2 2.4, 6.8 1.1, -1.7 0.3, -1.1
3 0.2, 4.5 1.7, -2.6 -0.5, 0.7
4 0.7, 4.4 1.5, -2.2 -0.4, 0.1
5 0.6, 4.4 1.5, -2.2 0.2, -0.5
6 0.6, 4.3 1.2, -1.9 -0.1, -0.2

ProtaStructure v3.0.4 Page 25


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

7 0.8, 4.5 1.7, -2.5 -0.1, -0.2

Critical Loading: 3 - (G+Q *F1)


min Design
N 4.5 - 4.5 kN
M11 -2.6 -0.1 -3.3 kN.m
M22 0.7 0.1 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.004
=
Beta = 1.00

Vd(1/2) = 0.5 / 1.7 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.74 / 0.76 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.04 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C24 (C-12) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 125.4, 129.8 2.0, -1.1 -3.6, 2.2
2 106.1, 110.4 1.2, -0.6 -3.7, 2.3
3 104.0, 108.3 2.0, -1.2 -2.1, 1.3
4 107.8, 111.5 1.8, -1.0 -4.5, 3.6
5 105.2, 109.0 1.6, -0.8 -1.5, 0.2
6 107.7, 111.5 0.0, 0.9 -3.0, 1.9

7 105.3, 109.0 3.3, -2.8 -3.0, 1.9

Critical Loading: 1 - (G*F)


min Design
N 129.8 - 129.8 kN
M11 2.0 1.5 0.0 kN.m
M22 -3.6 -1.5 -5.3 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.103
=
Beta = 0.88

Vd(1/2) = 0.7 / 0.3 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.85 / 0.85 N/mm2 Le1/b1 = 8.5 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.01 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C24 (C-12) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 3.6, 8.0 1.1, -1.8 -2.0, 3.6

ProtaStructure v3.0.4 Page 26


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

2 3.7, 8.0 0.7, -1.1 -1.9, 3.6


3 3.2, 7.6 1.1, -1.8 -1.4, 2.2
4 3.3, 7.1 0.9, -1.5 -1.9, 3.1
5 3.1, 6.8 0.9, -1.5 -1.5, 2.9
6 3.1, 6.8 0.6, -1.2 -1.7, 3.0
7 3.3, 7.0 1.2, -1.8 -1.7, 3.0

Critical Loading: 1 - (G*F)


min Design
N 8.0 - 8.0 kN
M11 -1.8 -0.1 0.0 kN.m
M22 3.6 0.1 5.3 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.006
=
Beta = 0.99

Vd(1/2) = 2.2 / 1.2 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.75 / 0.77 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.05 / 0.02 N/mm2 Le2/b2 = 8.1 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C25 (D-1) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 36.6, 40.9 0.9, -0.5 0.7, -0.4
2 38.1, 42.5 0.8, -0.4 0.7, -0.4
3 24.4, 28.7 0.7, -0.4 0.4, -0.2
4 29.5, 33.3 0.7, -0.3 -0.9, 1.4
5 32.6, 36.3 0.9, -0.5 2.1, -2.0
6 28.3, 32.0 -0.7, 1.3 0.6, -0.3

7 33.9, 37.6 2.3, -2.1 0.6, -0.3

Critical Loading: 1 - (G*F)


min Design
N 40.9 - 40.9 kN
M11 0.9 0.5 1.6 kN.m
M22 0.7 0.5 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.032
=
Beta = 0.96

Vd(1/2) = 1.6 / 1.7 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.80 / 0.82 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.03 / 0.04 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C25 (D-1) (225/225)


ProtaStructure v3.0.4 Page 27
SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

(C25 / Grade 380 (Type 2))


NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 11.2, 15.6 0.9, -1.0 0.7, -1.0
2 10.3, 14.7 0.7, -0.9 0.7, -0.9
3 8.8, 13.2 0.7, -0.8 0.5, -0.6
4 9.5, 13.2 0.7, -0.8 0.4, -0.7
5 9.7, 13.4 0.7, -0.8 0.8, -0.9
6 9.4, 13.1 0.5, -0.7 0.6, -0.8
7 9.8, 13.5 0.9, -1.0 0.6, -0.8

Critical Loading: 1 - (G*F)


min Design
N 15.6 - 15.6 kN
M11 -1.0 -0.2 -1.9 kN.m
M22 -1.0 -0.2 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.012
=
Beta = 0.99

Vd(1/2) = 0.7 / 0.8 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.76 / 0.78 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.02 N/mm2 Le2/b2 = 8.1 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C26 (D-2) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 63.1, 67.4 1.9, -1.1 -0.1, 0.1
2 55.5, 59.9 1.5, -0.8 -0.4, 0.3
3 49.9, 54.2 1.7, -1.0 0.2, -0.1
4 53.8, 57.5 1.6, -0.8 -1.7, 1.9
5 53.0, 56.7 1.7, -1.0 1.5, -1.7
6 50.6, 54.4 0.1, 0.8 -0.1, 0.1

7 56.1, 59.9 3.1, -2.6 -0.1, 0.1

Critical Loading: 1 - (G*F)


min Design
N 67.4 - 67.4 kN
M11 1.9 0.8 2.6 kN.m
M22 0.1 0.8 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.053
=
Beta = 0.94

Vd(1/2) = 0.1 / 0.3 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.81 / 0.80 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.00 / 0.01 N/mm2 Le2/b2 = 8.6 < 15.0 √

ProtaStructure v3.0.4 Page 28


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

Madd(1/2) = 0.0 / 0.0 kN.m 4Y16


Links = Y10-175

2C26 (D-2) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 23.0, 27.3 2.3, -2.5 0.0, 0.1
2 18.6, 23.0 1.8, -2.0 -0.2, 0.3
3 20.1, 24.5 2.1, -2.2 0.2, -0.2
4 19.6, 23.3 2.0, -2.1 -0.3, 0.3
5 19.5, 23.2 2.0, -2.1 0.3, -0.2
6 19.4, 23.1 1.8, -2.0 0.0, 0.1

7 19.7, 23.5 2.2, -2.3 0.0, 0.1

Critical Loading: 1 - (G*F)


min Design
N 27.3 - 27.3 kN
M11 -2.5 -0.3 -2.8 kN.m
M22 0.1 0.3 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.022
=
Beta = 0.97

Vd(1/2) = 0.0 / 1.8 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.76 / 0.79 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.00 / 0.04 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C27 (D-3) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 62.2, 66.6 1.9, -1.1 -0.1, 0.1
2 56.4, 60.8 1.5, -0.8 0.2, -0.1
3 47.7, 52.1 1.7, -1.0 -0.3, 0.2
4 52.6, 56.3 1.6, -0.9 -1.7, 1.9
5 52.8, 56.5 1.7, -1.0 1.5, -1.7
6 49.9, 53.7 0.1, 0.8 -0.1, 0.1

7 55.5, 59.2 3.1, -2.6 -0.1, 0.1

Critical Loading: 1 - (G*F)


min Design
N 66.6 - 66.6 kN
M11 1.9 0.7 2.6 kN.m
M22 0.1 0.7 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

ProtaStructure v3.0.4 Page 29


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

N/bhFcu 0.053
=
Beta = 0.94

Vd(1/2) = 1.4 / 0.3 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.84 / 0.80 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.03 / 0.01 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C27 (D-3) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 22.4, 26.7 2.1, -2.3 -0.1, 0.1
2 18.0, 22.3 1.5, -1.7 0.1, -0.2
3 19.7, 24.0 2.0, -2.0 -0.3, 0.4
4 19.1, 22.8 1.8, -1.9 -0.4, 0.3
5 19.0, 22.7 1.8, -1.9 0.2, -0.2
6 18.9, 22.6 1.6, -1.8 -0.1, 0.1

7 19.2, 22.9 2.0, -2.1 -0.1, 0.1

Critical Loading: 1 - (G*F)


min Design
N 26.7 - 26.7 kN
M11 -2.3 -0.3 -2.6 kN.m
M22 -0.1 -0.3 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.021
=
Beta = 0.97

Vd(1/2) = 0.1 / 1.6 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.77 / 0.79 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.00 / 0.03 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C28 (D-4) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 62.1, 66.5 1.9, -1.1 -0.1, 0.1
2 56.4, 60.7 1.4, -0.8 -0.4, 0.3
3 47.6, 52.0 1.7, -0.9 0.2, -0.1
4 52.6, 56.3 1.6, -0.9 -1.7, 1.9
5 52.7, 56.4 1.6, -0.9 1.5, -1.7
6 49.8, 53.6 0.1, 0.8 -0.1, 0.1

7 55.4, 59.1 3.1, -2.6 -0.1, 0.1

Critical Loading: 1 - (G*F)


min Design

ProtaStructure v3.0.4 Page 30


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

N 66.5 - 66.5 kN
M11 1.9 0.7 2.6 kN.m
M22 0.1 0.7 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.053
=
Beta = 0.94

Vd(1/2) = 0.1 / 0.3 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.80 / 0.80 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.00 / 0.01 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C28 (D-4) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 22.3, 26.6 2.1, -2.2 0.0, 0.1
2 17.9, 22.2 1.5, -1.7 -0.2, 0.4
3 19.6, 23.9 1.9, -2.0 0.2, -0.3
4 19.0, 22.7 1.7, -1.9 -0.3, 0.3
5 19.0, 22.7 1.7, -1.9 0.2, -0.2
6 18.8, 22.5 1.5, -1.7 0.0, 0.1

7 19.1, 22.9 1.9, -2.0 0.0, 0.1

Critical Loading: 1 - (G*F)


min Design
N 26.6 - 26.6 kN
M11 -2.2 -0.3 -2.5 kN.m
M22 0.1 0.3 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.021
=
Beta = 0.97

Vd(1/2) = 0.2 / 1.6 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.77 / 0.79 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.00 / 0.03 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C29 (D-5) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 63.9, 68.3 2.0, -1.1 -0.1, 0.1
2 57.7, 62.0 1.6, -0.9 0.2, -0.1
3 49.3, 53.6 1.8, -1.0 -0.3, 0.2
4 54.1, 57.8 1.7, -1.0 -1.6, 1.8
5 54.2, 58.0 1.7, -1.0 1.5, -1.7

ProtaStructure v3.0.4 Page 31


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

6 51.4, 55.1 0.2, 0.8 -0.1, 0.1


7 56.9, 60.7 3.2, -2.7 -0.1, 0.1

Critical Loading: 1 - (G*F)


min Design
N 68.3 - 68.3 kN
M11 2.0 0.8 2.7 kN.m
M22 0.1 0.8 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.054
=
Beta = 0.94

Vd(1/2) = 1.4 / 0.2 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.84 / 0.80 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.03 / 0.00 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C29 (D-5) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 22.0, 26.3 2.2, -2.4 -0.2, 0.1
2 17.8, 22.2 1.6, -1.8 0.1, -0.2
3 19.3, 23.6 2.0, -2.1 -0.3, 0.4
4 18.7, 22.4 1.9, -2.0 -0.4, 0.3
5 18.8, 22.5 1.9, -2.0 0.1, -0.2
6 18.6, 22.3 1.7, -1.9 -0.1, 0.1

7 18.9, 22.6 2.1, -2.2 -0.1, 0.1

Critical Loading: 1 - (G*F)


min Design
N 26.3 - 26.3 kN
M11 -2.4 -0.3 -2.7 kN.m
M22 -0.2 -0.3 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.021
=
Beta = 0.98

Vd(1/2) = 0.1 / 1.7 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.77 / 0.79 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.00 / 0.03 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C30 (D-6) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)

ProtaStructure v3.0.4 Page 32


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

1 40.3, 44.7 1.0, -0.5 -0.6, 0.4


2 42.3, 46.7 0.9, -0.4 -0.7, 0.5
3 26.6, 31.0 0.9, -0.4 -0.3, 0.2
4 34.2, 37.9 0.9, -0.5 -2.1, 2.1
5 34.4, 38.1 0.9, -0.4 1.0, -1.4
6 31.5, 35.2 -0.6, 1.3 -0.5, 0.4
7 37.1, 40.8 2.4, -2.2 -0.5, 0.4

Critical Loading: 1 - (G*F)


min Design
N 44.7 - 44.7 kN
M11 1.0 0.5 1.7 kN.m
M22 -0.6 -0.5 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.035
=
Beta = 0.96

Vd(1/2) = 1.7 / 1.8 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.80 / 0.82 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.03 / 0.04 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C30 (D-6) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 16.0, 20.3 1.1, -1.1 -0.5, 0.7
2 13.9, 18.3 0.9, -1.0 -0.5, 0.7
3 13.2, 17.6 0.9, -0.9 -0.3, 0.4
4 13.7, 17.4 0.9, -1.0 -0.7, 0.8
5 13.6, 17.3 0.9, -1.0 -0.1, 0.3
6 13.5, 17.2 0.7, -0.8 -0.4, 0.6

7 13.8, 17.5 1.1, -1.1 -0.4, 0.6

Critical Loading: 1 - (G*F)


min Design
N 20.3 - 20.3 kN
M11 -1.1 -0.2 -1.8 kN.m
M22 0.7 0.2 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.016
=
Beta = 0.98

Vd(1/2) = 0.6 / 0.9 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.77 / 0.78 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.01 / 0.02 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

ProtaStructure v3.0.4 Page 33


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

1C31 (D-7) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 40.3, 44.7 1.0, -0.5 0.4, -0.2
2 42.3, 46.7 0.9, -0.4 0.5, -0.3
3 26.6, 31.0 0.8, -0.4 0.2, -0.1
4 34.4, 38.1 0.8, -0.4 -1.2, 1.6
5 34.2, 37.9 0.9, -0.5 1.9, -2.0
6 31.5, 35.2 -0.6, 1.3 0.4, -0.2

7 37.1, 40.8 2.4, -2.2 0.4, -0.2

Critical Loading: 1 - (G*F)


min Design
N 44.7 - 44.7 kN
M11 1.0 0.5 1.5 kN.m
M22 0.4 0.5 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.035
=
Beta = 0.96

Vd(1/2) = 1.5 / 1.8 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.80 / 0.82 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.03 / 0.04 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C31 (D-7) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 16.0, 20.3 1.1, -1.1 0.4, -0.5
2 14.0, 18.3 0.9, -1.0 0.4, -0.6
3 13.2, 17.6 0.9, -0.9 0.2, -0.3
4 13.6, 17.3 0.9, -1.0 0.0, -0.2
5 13.7, 17.4 0.9, -1.0 0.6, -0.7
6 13.5, 17.2 0.7, -0.8 0.3, -0.5

7 13.8, 17.5 1.1, -1.1 0.3, -0.5

Critical Loading: 1 - (G*F)


min Design
N 20.3 - 20.3 kN
M11 -1.1 -0.2 -1.7 kN.m
M22 -0.5 -0.2 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.016
=

ProtaStructure v3.0.4 Page 34


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

Beta = 0.98

Vd(1/2) = 0.1 / 0.9 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.76 / 0.78 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.00 / 0.02 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C32 (D-8) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 63.9, 68.3 2.0, -1.1 -0.1, 0.1
2 57.7, 62.0 1.6, -0.9 -0.4, 0.3
3 49.2, 53.6 1.8, -1.0 0.2, -0.1
4 54.2, 58.0 1.7, -1.0 -1.7, 1.9
5 54.1, 57.8 1.7, -0.9 1.5, -1.7
6 51.3, 55.1 0.2, 0.8 -0.1, 0.1

7 57.0, 60.7 3.2, -2.7 -0.1, 0.1

Critical Loading: 1 - (G*F)


min Design
N 68.3 - 68.3 kN
M11 2.0 0.8 2.7 kN.m
M22 0.1 0.8 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.054
=
Beta = 0.94

Vd(1/2) = 0.1 / 0.2 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.81 / 0.80 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.00 / 0.01 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C32 (D-8) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 22.0, 26.3 2.2, -2.4 0.0, 0.0
2 17.8, 22.2 1.6, -1.8 -0.2, 0.3
3 19.3, 23.6 2.0, -2.1 0.2, -0.3
4 18.8, 22.5 1.9, -2.0 -0.2, 0.3
5 18.7, 22.4 1.9, -2.0 0.3, -0.2
6 18.6, 22.3 1.7, -1.9 0.0, 0.0

7 18.9, 22.6 2.1, -2.2 0.0, 0.0

Critical Loading: 1 - (G*F)


min Design
N 26.3 - 26.3 kN
M11 -2.4 -0.3 -2.7 kN.m
M22 0.0 0.3 0.0 kN.m

ProtaStructure v3.0.4 Page 35


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.021
=
Beta = 0.98

Vd(1/2) = 0.0 / 1.7 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.74 / 0.79 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.00 / 0.03 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C33 (D-9) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 62.1, 66.4 1.9, -1.1 -0.1, 0.1
2 56.4, 60.7 1.5, -0.8 0.2, -0.1
3 47.6, 51.9 1.7, -0.9 -0.3, 0.2
4 52.6, 56.4 1.6, -0.9 -1.7, 1.9
5 52.6, 56.3 1.6, -0.9 1.5, -1.7
6 49.8, 53.5 0.1, 0.9 -0.1, 0.1

7 55.4, 59.1 3.1, -2.6 -0.1, 0.1

Critical Loading: 1 - (G*F)


min Design
N 66.4 - 66.4 kN
M11 1.9 0.7 2.6 kN.m
M22 0.1 0.7 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.052
=
Beta = 0.94

Vd(1/2) = 1.4 / 0.3 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.84 / 0.80 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.03 / 0.01 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C33 (D-9) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 22.3, 26.6 2.0, -2.2 -0.1, 0.1
2 17.9, 22.2 1.5, -1.7 0.1, -0.2
3 19.6, 23.9 1.9, -1.9 -0.3, 0.4
4 19.0, 22.7 1.7, -1.9 -0.3, 0.3
5 18.9, 22.7 1.7, -1.9 0.2, -0.2
6 18.8, 22.5 1.5, -1.7 -0.1, 0.1

ProtaStructure v3.0.4 Page 36


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

7 19.1, 22.8 1.9, -2.0 -0.1, 0.1

Critical Loading: 1 - (G*F)


min Design
N 26.6 - 26.6 kN
M11 -2.2 -0.3 -2.5 kN.m
M22 -0.1 -0.3 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.021
=
Beta = 0.97

Vd(1/2) = 0.1 / 1.6 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.77 / 0.79 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.00 / 0.03 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C34 (D-10) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 61.9, 66.3 1.9, -1.1 -0.1, 0.1
2 56.2, 60.6 1.5, -0.8 -0.4, 0.3
3 47.5, 51.8 1.7, -0.9 0.2, -0.1
4 52.6, 56.3 1.7, -0.9 -1.7, 1.9
5 52.4, 56.1 1.6, -0.9 1.5, -1.7
6 49.7, 53.4 0.1, 0.9 -0.1, 0.1

7 55.3, 59.0 3.1, -2.7 -0.1, 0.1

Critical Loading: 1 - (G*F)


min Design
N 66.3 - 66.3 kN
M11 1.9 0.7 2.6 kN.m
M22 0.1 0.7 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.052
=
Beta = 0.94

Vd(1/2) = 0.1 / 0.3 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.80 / 0.80 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.00 / 0.01 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C34 (D-10) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 22.3, 26.6 2.1, -2.2 0.0, 0.0

ProtaStructure v3.0.4 Page 37


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

2 17.9, 22.2 1.5, -1.7 -0.2, 0.3


3 19.6, 23.9 1.9, -1.9 0.2, -0.3
4 18.9, 22.6 1.7, -1.9 -0.3, 0.3
5 19.0, 22.7 1.7, -1.9 0.3, -0.2
6 18.8, 22.5 1.5, -1.7 0.0, 0.0
7 19.1, 22.8 1.9, -2.0 0.0, 0.0

Critical Loading: 1 - (G*F)


min Design
N 26.6 - 26.6 kN
M11 -2.2 -0.3 -2.5 kN.m
M22 0.0 0.3 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.021
=
Beta = 0.97

Vd(1/2) = 0.0 / 1.6 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.76 / 0.79 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.00 / 0.03 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C35 (D-11) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 65.4, 69.7 2.0, -1.1 0.0, 0.1
2 59.1, 63.4 1.5, -0.9 0.3, -0.1
3 50.1, 54.5 1.7, -1.0 -0.3, 0.2
4 55.0, 58.7 1.8, -1.0 -1.6, 1.8
5 55.7, 59.4 1.6, -0.9 1.6, -1.7
6 52.6, 56.3 0.2, 0.8 0.0, 0.0

7 58.2, 61.9 3.2, -2.7 0.0, 0.0

Critical Loading: 1 - (G*F)


min Design
N 69.7 - 69.7 kN
M11 2.0 0.8 2.7 kN.m
M22 0.1 0.8 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.055
=
Beta = 0.93

Vd(1/2) = 0.0 / 0.3 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.80 / 0.80 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.00 / 0.01 N/mm2 Le2/b2 = 8.6 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

2C35 (D-11) (225/225)


ProtaStructure v3.0.4 Page 38
SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

(C25 / Grade 380 (Type 2))


NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 22.5, 26.8 2.2, -2.4 -0.1, 0.0
2 18.2, 22.6 1.6, -1.8 0.2, -0.3
3 19.7, 24.0 2.0, -2.1 -0.2, 0.3
4 19.1, 22.8 1.9, -2.0 -0.3, 0.3
5 19.1, 22.8 1.9, -2.0 0.2, -0.3
6 19.0, 22.7 1.7, -1.8 0.0, 0.0
7 19.3, 23.0 2.1, -2.2 0.0, 0.0

Critical Loading: 1 - (G*F)


min Design
N 26.8 - 26.8 kN
M11 -2.4 -0.3 -2.7 kN.m
M22 -0.1 -0.3 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.021
=
Beta = 0.97

Vd(1/2) = 0.0 / 1.7 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.75 / 0.79 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.00 / 0.03 N/mm2 Le2/b2 = 8.0 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

1C36 (D-12) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 34.4, 38.8 1.1, -0.6 -1.0, 0.7
2 38.2, 42.5 0.9, -0.5 -1.1, 0.7
3 20.8, 25.1 0.9, -0.5 -0.6, 0.4
4 30.7, 34.4 1.0, -0.6 -2.3, 2.3
5 27.8, 31.5 0.9, -0.4 0.6, -1.1
6 26.4, 30.1 -0.6, 1.3 -0.9, 0.6

7 32.1, 35.8 2.5, -2.2 -0.9, 0.6

Critical Loading: 1 - (G*F)


min Design
N 38.8 - 38.8 kN
M11 1.1 0.4 2.1 kN.m
M22 -1.0 -0.4 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.031
=
Beta = 0.96

Vd(1/2) = 1.8 / 1.9 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.80 / 0.81 N/mm2 Le1/b1 = 8.6 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.04 / 0.04 N/mm2 Le2/b2 = 8.6 < 15.0 √

ProtaStructure v3.0.4 Page 39


SHOP MICHESTHER ENGINEERING
Column Reinforcement Design Calc. By:
Rev: 1 Checked By:

Madd(1/2) = 0.0 / 0.0 kN.m 4Y16


Links = Y10-175

2C36 (D-12) (225/225)


(C25 / Grade 380 (Type 2))
NTop/Bot M11 Top/Bot M22 Top/Bot
No
(kN) (kN.m) (kN.m)
1 13.2, 17.6 1.3, -1.3 -1.0, 1.2
2 12.1, 16.4 1.0, -1.1 -0.9, 1.2
3 10.3, 14.7 1.1, -1.0 -0.7, 0.8
4 11.4, 15.1 1.1, -1.1 -1.0, 1.2
5 11.1, 14.8 1.1, -1.1 -0.6, 0.9
6 11.1, 14.8 0.9, -0.9 -0.8, 1.0

7 11.4, 15.1 1.3, -1.3 -0.8, 1.0

Critical Loading: 1 - (G*F)


min Design
N 17.6 - 17.6 kN
M11 -1.3 -0.2 -2.5 kN.m
M22 1.2 0.2 0.0 kN.m
Nmax 506.3
Concrete Cover = 25.0 mm
BS8110-
Cl.3.8.4.
5

N/bhFcu 0.014
=
Beta = 0.98

Vd(1/2) = 0.8 / 1.0 kN Short Column... As (Req): %0.40 (min) 202.50 mm2
vc'(1/2) = 0.76 / 0.78 N/mm2 Le1/b1 = 8.0 < 15.0 √ As (Sup): %1.59 804.25 mm2
v(1/2) = 0.02 / 0.02 N/mm2 Le2/b2 = 8.1 < 15.0 √
Madd(1/2) = 0.0 / 0.0 kN.m 4Y16
Links = Y10-175

ProtaStructure v3.0.4 Page 40