You are on page 1of 8

_____________________________________________________________________

Company Name :
Job Description :
Designed by :
Date and Time : Friday, June 10, 2022 3:17:40 PM
(License Number: Timer-SN111-C0-1)
_____________________________________________________________________

COLUMN DESIGN FULL REPORT


MATERIAL AND DESIGN DATA
Load Allowance = 10 %
Code of Practice fcu (N/mm²) Ec, (N/mm²) fy (N/mm²) fyv (N/mm²) γc γs
BS8110 : 1997 30 24597 460 460 1.5 1.05

Cover (mm) Conc. Unit Weight (kN/m³) Steel Unit Weight (kg/m³)
25 24 7860

FLOOR gb COLUMN C38:(6,C)

Loading Cases
Total Selected Loading Cases = 8
Selected Loading Cases Table
Load Load Analysis
No. Source P My Mz T Vy Vz Myi Mzi
Case Comb. Type
1 G.L. Full LC1 Top 16841.4 157.7 -142.3 0.0 -18.0 -19.3 78.7 -71.0
2 G.L. Min LC1 Top 9663.9 157.7 -142.3 0.0 -18.0 -19.3 78.7 -71.0
3 G.L. Full LC1 Bot 16916.2 -0.2 0.2 0.0 -18.0 -19.3 78.7 -71.0
4 G.L. Min LC1 Bot 9717.4 -0.2 0.2 0.0 -18.0 -19.3 78.7 -71.0
5 N.L. 1 LC2 Comb. 13971.8 482.8 -47.0 0.0 -14.3 -148.2 238.2 -23.4
6 N.L. 2 LC2 Comb. 14009.1 47.0 -417.5 0.0 -128.5 -14.3 23.5 -205.5
7 N.L. 3 LC2 Comb. 14317.8 -389.3 -35.7 0.0 -10.8 119.9 -191.5 -17.8
8 N.L. 4 LC2 Comb. 14280.5 46.5 334.9 0.0 103.4 -14.1 23.2 164.2
Source - Source of Loading (G.L. for Gravity, N.L. for Notional Load)
Load Case - Load Case Number of Wind/Notional Load (Full or Minimum for Gravity), Load Comb. - Load Combination Number
Analysis Type - Type of Analysis (Top or Bottom Column Part for 2D, 3D for 3D Analysis, P-D for P-Delta Analysis)
P - Axial Force (kN), My / Mz - Bending Moment About Y-Y / Z-Z Axis (kNm)
T - Torsion Force (kN), Vy / Vz - Shear Force in Y-Y / Z-Z Axis (kN)
Myi / Mzi - Initial Bending Moment in Mid Length of Column About Y-Y / Z-Z Axis (kNm)
Load Allowance of 10% has been added to the loading for design purpose
My and Mz above are calculated using Load Allowance x M (from analysis)

Braced/Unbraced Condition Table


Column Clear Height, h = 3000 mm
No. P Vy Vz ∆y ∆z Qy Qz Cond.Y Cond.Z
1 - - - - - - - Braced Braced
2 - - - - - - - Braced Braced
3 - - - - - - - Braced Braced
4 - - - - - - - Braced Braced
5 13971.8 -14.3 -148.2 0.2 15.8 0.059 0.497 UnBraced UnBraced
6 14009.1 -128.5 -14.3 11.3 0.0 0.412 0.008 UnBraced Braced
7 14317.8 -10.8 119.9 -0.1 -15.8 0.050 0.628 UnBraced UnBraced
8 14280.5 103.4 -14.1 -11.3 0.0 0.519 1.48e-004 UnBraced Braced
P - Axial Force (kN), Vy / Vz - Shear Force in Y-Y / Z-Z Axis (kN), ∆y / ∆z - Column Drift in Y-Y / Z-Z Axis (mm)
Qy / Qz - Column Stability Index in Y-Y / Z-Z Axis (mm) (Q = P × ∆ / V × h)
Cond.Y / Cond.Z - Column Braced/Unbraced Condition in Y-Y / Z-Z Axis (mm), Limit Value = 0.05
All Gravity Load Cases Assigned as Braced regardless the Stability Index

Design / Analysis Result


License Number: Timer-SN111-C0-1
1/8
Selection of Moment for Design and Analysis
My Mz
No
2D/3D NeMin Mi Madd Selected Slender 2D/3D NeMin Mi Madd Selected Slender
1 157.7 336.8 - - 336.8 No -142.3 -336.8 - - -336.8 No
2 157.7 193.3 - - 193.3 No -142.3 -193.3 - - -193.3 No
3 -0.2 338.3 - - 338.3 No 0.2 -338.3 - - -338.3 No
4 -0.2 194.3 - - 194.3 No 0.2 -194.3 - - -194.3 No
5 482.8 279.4 238.2 -364.4 602.6 Yes -47.0 -279.4 -23.4 -304.2 -327.6 Yes
6 47.0 280.2 - - 47.0 No -417.5 -280.2 -205.5 -303.2 -508.7 Yes
7 -389.3 -286.4 -191.5 353.0 -544.6 Yes -35.7 -286.4 -17.8 -294.7 -312.6 Yes
8 46.5 285.6 - - 46.5 No 334.9 285.6 164.2 295.8 460.0 Yes
2D/3D - Moment values obtained from 2D/3D analysis process, kNm
NeMin - Moment due to minimum eccentricity x design ultimate axial load, kNm
Mi - Initial moment at the point of maximum additional moment, kNm, Madd - Additional Moment induced by deflection, kNm
Selected - Selected moment based on greater of 2D/3D, NeMin and Mi + Madd, kNm

Design / Analysis Result and Status


No Process FCap FApplied MyApplied MzApplied Status Fail Mode
1 Design 18417.9 16841.4 336.8 -336.8 Pass None
2 Analysis 18417.9 9663.9 193.3 -193.3 Pass None
3 Analysis 18417.9 16916.2 338.3 -338.3 Pass None
4 Analysis 18417.9 9717.4 194.3 -194.3 Pass None
5 Analysis 17047.2 13971.8 602.6 -327.6 Pass None
6 Analysis 18141.1 14009.1 47.0 -508.7 Pass None
7 Analysis 17355.3 14317.8 -544.6 -312.6 Pass None
8 Analysis 18353.0 14280.5 46.5 460.0 Pass None
Process - Indicated whether the load case is run through design / analysis process
F Cap - Maximum axial load capacity of the section (kN), F Applied - Applied axial load on the section (kN)
Status - Indicate the section Passed/Failed the process, Fail Mode - Mode of failure if the section failed

SLENDERNESS RESULT
Clause 3.8.1.6 : Effective Height of a column
Clause 3.8.3 : Deflection induced moments in solid slender columns
Column Dimension in Plane of Bending (About Y-Y Axis), Hyy = 300.0 mm
Column Dimension in Plane of Bending (About Z-Z Axis), Hzz = 900.0 mm

Slenderness Calculation About Y-Y Axis


Clear Length, lo = 3000.0 mmLateral Force, V = 0, Use Stability Index Q = 0 for Gravity Load, The Element is Braced

Total Column Stiffness at Top, I/L = 21093750 mm3


Total Column Stiffness at Bottom, I/L = 10546875 mm3
Floor Element Type Mark b, mm h, mm L, mm K, mm^3
1b Column (6,C) 300 900 3000 10546875
gb Column (6,C) 300 900 3000 10546875

Total stiffness of restraint elements (beams) at top part of column, KbTop = 784313.7 mm 3
No. Element Type Mark b, mm h, mm L, mm Angle, ° K, mm^3 Cantilever
1 Beam gb10-1 300 500 8500 180.0 367647 No
2 Beam gb10-2 300 500 7500 0.0 416667 No

Total stiffness of restraint elements (beams) at bottom part of column, KbBot = 0.0 mm 3
Relative Stiffness at Top of Element, αTop = 10.000 (Governed by Maximum Relative Stiffness)
Relative Stiffness at Bottom of Element, αBot = 5.000
β1 = 0.7 + 0.05 × (αTop + αBot) = 1.45, β2 = 0.85 + 0.05 × Min (αTop, αBot) = 1.10
β = Min (β1, β2) = 1.10 > 1.0, β taken as 1.0
Effective Length, leff = 1.00 × lo = 3000.0 mm
leff / H = 3000.0 / 300.0 = 10.0 < 15
The Column Is Short About Y-Y Axis

License Number: Timer-SN111-C0-1


2/8
Slenderness Calculation About Z-Z Axis
Member Clear Length, lo = 3000.0 mmLateral Force, V = 0, Use Stability Index Q = 0 for Gravity Load, The Element is Braced

Total Column Stiffness at Top, I/L = 30375000 mm3


Total Column Stiffness at Bottom, I/L = 15187500 mm3
Floor Element Type Mark b, mm h, mm L, mm K, mm^3
1b Column (6,C) 300 900 3000 15187500
gb Column (6,C) 300 900 3000 15187500

Total stiffness of restraint elements (beams) at top part of column, KbTop = 837053.6 mm 3
No. Element Type Mark b, mm h, mm L, mm Angle, ° K, mm^3 Cantilever
1 Beam gb3-1 300 500 8000 270.0 390625 No
2 Beam gb3-2 300 500 7000 90.0 446429 No

Total stiffness of restraint elements (beams) at bottom part of column, KbBot = 0.0 mm 3
Relative Stiffness at Top of Element, αTop = 10.000 (Governed by Maximum Relative Stiffness)
Relative Stiffness at Bottom of Element, αBot = 5.000
β1 = 0.7 + 0.05 × (αTop + αBot) = 1.45, β2 = 0.85 + 0.05 × Min (αTop, αBot) = 1.10
β = Min (β1, β2) = 1.10 > 1.0, β taken as 1.0
Effective Length, leff = 1.00 × lo = 3000.0 mm
leff / H = 3000.0 / 900.0 = 3.3 < 15
The Column Is Short About Z-Z Axis

Section Data
Code of Practice used : BS8110 : 1997

Type of Section Selected : Rectangular Shape


Reinforcement provided : 32T32 (3.81%)

 General Data
Concrete Area = 675000.0 mm²
Steel Bar Area = 25735.9 mm²
Steel Ratio = 3.8127 %

Concrete Cover = 25.0 mm


Link Diameter = 10 mm

License Number: Timer-SN111-C0-1


3/8
Figure 1 : Section Dimension

Length of Edges: a = 300.0 mm, b = 900.0 mm, c = 300.0 mm, d = 900.0 mm


Angle of Rotation = 0.0 °

Material Data
Concrete Test Specimen Type : Cube
Concrete Cube Strength, fcu = 30.0 N/mm²
Steel Yield Strength, fy = 460.0 N/mm²
Ultimate Strain of Concrete, εcu = 0.0035
Elastic Modulus of Concrete, Ec = 24597.0 N/mm²
Elastic Modulus of Steel, Es = 200000.0 N/mm ²

Partial Safety Factor of Material for Concrete, γc = 1.50


Partial Safety Factor of Material for Steel, γs = 1.05

Loading Data
Mx and My is taken with respect to the geometrical centroid of the section
Applied Axial Load = 16841.4 kN
Applied Bending Moment about X-X Axis = -336.8 kNm
Applied Bending Moment about Y-Y Axis = -336.8 kNm

Display Outer Vertex For Section Profile Polygon


Points x (mm) y (mm)
0 16125.0 31050.0
1 16875.0 31050.0
2 16875.0 31950.0
3 16125.0 31950.0

Design Status
Moment is taken at the plastic centroid
Axial Force(F) Applied = 16841.38 kN
Axial Force(F) Capacity = 18417.95 kN
License Number: Timer-SN111-C0-1
4/8
Applied Bending Moment about X-X Axis = -336.83 kNm
Bending Moment Capacity about X-X Axis = -368.36 kNm

Applied Bending Moment about Y-Y Axis = -336.83 kNm


Bending Moment Capacity about Y-Y Axis = -368.36 kNm

Design Passed
Reinforcement provided: 32T32 (3.81%)

k value = 0.920

Note:
k value = √ ((AsReq) / (AsProv))
AsReq = Area of steel required (mm²)
AsProv = Area of steel provided (mm²)

Concrete contribution

Figure 2 : Neutral Axis Diagram


Equivalent compressive stress block area = 675000.00 mm²
Centroid of equivalent compression Area, X = 0.00mm
Centroid of equivalent compression Area, Y = 0.00mm

Reinforcement Result

Figure 3 : Steel Bar Arrangement Diagram

License Number: Timer-SN111-C0-1


5/8
Reinforcement Bar Result
Bar X,mm Y,mm A,mm² NA,mm Strain,1e-3 Stress,N/mm² P,kN Mx,kNm My,kNm
1 16176.0 31101.0 804.2 -1406.0 3.33 438.1 352.34 -140.58 -114.16
2 16824.0 31101.0 804.2 -865.2 2.05 410.1 329.85 -131.61 106.87
3 16257.0 31101.0 804.2 -1338.4 3.17 438.1 352.34 -140.58 -85.62
4 16338.0 31101.0 804.2 -1270.8 3.01 438.1 352.34 -140.58 -57.08
5 16419.0 31101.0 804.2 -1203.2 2.85 438.1 352.34 -140.58 -28.54
6 16500.0 31101.0 804.2 -1135.6 2.69 438.1 352.34 -140.58 0.00
7 16581.0 31101.0 804.2 -1068.0 2.53 438.1 352.34 -140.58 28.54
8 16662.0 31101.0 804.2 -1000.4 2.37 438.1 352.34 -140.58 57.08
9 16743.0 31101.0 804.2 -932.8 2.21 438.1 352.34 -140.58 85.62
10 16824.0 31200.8 804.2 -810.2 1.92 384.1 308.90 -92.44 100.08
11 16824.0 31300.5 804.2 -755.3 1.79 358.0 287.95 -57.45 93.30
12 16824.0 31400.3 804.2 -700.4 1.66 332.0 267.00 -26.63 86.51
13 16824.0 31500.0 804.2 -645.4 1.53 305.9 246.06 0.00 79.72
14 16824.0 31599.8 804.2 -590.5 1.40 279.9 225.11 22.45 72.93
15 16824.0 31699.5 804.2 -535.5 1.27 253.8 204.16 40.73 66.15
16 16824.0 31799.3 804.2 -480.6 1.14 227.8 183.21 54.82 59.36
17 16824.0 31899.0 804.2 -425.6 1.01 201.8 162.26 64.74 52.57
18 16176.0 31899.0 804.2 -966.4 2.29 438.1 352.34 140.58 -114.16
19 16743.0 31899.0 804.2 -493.2 1.17 233.8 188.03 75.02 45.69
20 16662.0 31899.0 804.2 -560.8 1.33 265.8 213.80 85.31 34.64
21 16581.0 31899.0 804.2 -628.4 1.49 297.9 239.58 95.59 19.41
22 16500.0 31899.0 804.2 -696.0 1.65 329.9 265.35 105.87 0.00
23 16419.0 31899.0 804.2 -763.6 1.81 362.0 291.12 116.16 -23.58
24 16338.0 31899.0 804.2 -831.2 1.97 394.0 316.90 126.44 -51.34
25 16257.0 31899.0 804.2 -898.8 2.13 426.1 342.67 136.72 -83.27
26 16176.0 31799.3 804.2 -1021.4 2.42 438.1 352.34 105.44 -114.16
27 16176.0 31699.5 804.2 -1076.3 2.55 438.1 352.34 70.29 -114.16
28 16176.0 31599.8 804.2 -1131.3 2.68 438.1 352.34 35.15 -114.16
29 16176.0 31500.0 804.2 -1186.2 2.81 438.1 352.34 0.00 -114.16
30 16176.0 31400.3 804.2 -1241.2 2.94 438.1 352.34 -35.15 -114.16
31 16176.0 31300.5 804.2 -1296.1 3.07 438.1 352.34 -70.29 -114.16
32 16176.0 31200.8 804.2 -1351.1 3.20 438.1 352.34 -105.44 -114.16
Total 9709.34 -368.34 -368.37

Percentage of steel bar = 3.81 %

Verification
Verification of the output results for the Axial Load Capacity
Contribution from concrete = 675000.00*0.447*30.0/1000 = 9053.8 kN
Contribution from displaced concrete force =
(804.2+804.2+804.2+804.2+804.2+804.2+804.2+804.2+804.2+804.2+804.2+804.2+804.2+804.2+804.2+804.2+804.2+804.2+804.2+
804.2+804.2+804.2+804.2+804.2+804.2+804.2+804.2+804.2+804.2+804.2+804.2+804.2)*0.447*30.00/1000 = 345.20kN
Contribution from reinforcement bars = 9709.34kN
Contribution from composite steel = 0.00kN
Total Axial load = 1.00*(9053.81-345.20+9709.34+0.00) = 18417.96kN

Verification of output results for moment X


The extra moment due to offset in plastic centroid = 0.00kNm
Contribution from concrete = 675000.00*0.447*30.00*(0.00)*/10^6 = 0.00kNm
Contribution from displaced concrete =
(804.2*(-399.0)+804.2*(-399.0)+804.2*(-399.0)+804.2*(-399.0)+804.2*(-399.0)+804.2*(-399.0)+804.2*(-399.0)+804.2*(-399.0)+80
4.2*(-399.0)+804.2*(-299.2)+804.2*(-199.5)+804.2*(-99.7)+804.2*(0.0)+804.2*(99.8)+804.2*(199.5)+804.2*(299.3)+804.2*(399.0)
+804.2*(399.0)+804.2*(399.0)+804.2*(399.0)+804.2*(399.0)+804.2*(399.0)+804.2*(399.0)+804.2*(399.0)+804.2*(399.0)+804.2*(2
License Number: Timer-SN111-C0-1
6/8
99.3)+804.2*(199.5)+804.2*(99.8)+804.2*(0.0)+804.2*(-99.7)+804.2*(-199.5)+804.2*(-299.2))*0.447*30.00/106 = 0.00kNm
Contribution from reinforcement bar = -368.34kNm
Contribution from composite steel = 0.00kNm
Total Moment X(Plastic Centroid) =1.00*(0.00+0.00-368.34+0.00) = -368.34kNm

Verification of output results for moment Y


The extra moment due to offset in plastic centroid = 0.00kNm
Contribution from concrete = 675000.00*0.447*30.00*(0.00)*/10^6 = 0.00kNm
Contribution from displaced concrete =
(804.2*(-324.0)+804.2*(324.0)+804.2*(-243.0)+804.2*(-162.0)+804.2*(-81.0)+804.2*(0.0)+804.2*(81.0)+804.2*(162.0)+804.2*(243
.0)+804.2*(324.0)+804.2*(324.0)+804.2*(324.0)+804.2*(324.0)+804.2*(324.0)+804.2*(324.0)+804.2*(324.0)+804.2*(324.0)+804.2
*(-324.0)+804.2*(243.0)+804.2*(162.0)+804.2*(81.0)+804.2*(0.0)+804.2*(-81.0)+804.2*(-162.0)+804.2*(-243.0)+804.2*(-324.0)+8
04.2*(-324.0)+804.2*(-324.0)+804.2*(-324.0)+804.2*(-324.0)+804.2*(-324.0)+804.2*(-324.0))*0.447*30.00/106 = 0.00kNm
Contribution from reinforcement bar = -368.37kNm
Contribution from composite steel = 0.00kNm
Total Moment Y(Plastic Centroid) =1.00*(0.00+0.00-368.37+0.00) = -368.37kNm

Note for Verification Calculation:


Concrete Moment Capacity, Fcd = Fcc*Lever Arm
Concrete Axial Load Capacity, Fcc = Ac*σc,max
Ac = Equivalent compressive stress block area or concrete area
Maximum concrete stress, σc,max = k1/(2*k2) = 0.404*fcu/(2*0.452) = 0.447*fcu
k1 = Average Concrete Stress above Neutral Axis
k2 = Concrete Lever Arm Factor

Shear & Torsion Design / Checking


Part 1 Clause 3.8.4.6: Shear in columns
Limit about X-X Axis, rXX = 0.6 × Hy = 0.6 × 900 / 1000 = 0.5400 m
Limit about Y-Y Axis, rYY = 0.6 × Hx = 0.6 × 300 / 1000 = 0.4500 m

Table of axial forces, moments and M / N ratios for each load case
No P (kN) My (kNm) Mz (kNm) My / P (m) Mz / P (m)
1 16841.4 -336.8 -336.8 -0.0200 <= 0.4500 -0.0200 <= 0.5400
2 9663.9 -193.3 -193.3 -0.0200 <= 0.4500 -0.0200 <= 0.5400
3 16916.2 -338.3 -338.3 -0.0200 <= 0.4500 -0.0200 <= 0.5400
4 9717.4 -194.3 -194.3 -0.0200 <= 0.4500 -0.0200 <= 0.5400
5 13971.8 -602.6 -327.6 -0.0431 <= 0.4500 -0.0234 <= 0.5400
6 14009.1 -47.0 -508.7 -0.0034 <= 0.4500 -0.0363 <= 0.5400
7 14317.8 544.6 -312.6 0.0380 <= 0.4500 -0.0218 <= 0.5400
8 14280.5 -46.5 460.0 -0.0033 <= 0.4500 0.0322 <= 0.5400
P - Axial Force, My / Mz - Bending Moment About Y-Y / Z-Z Axis
My / P, Mz / P - Bending Moment over Axial Force Ratio

No check is required for shear because all the load cases within the limit as specified in BS8110:Part1 Clause 3.8.4.6

Main Bar Diameter, diaMain = 32.0 mm, Link Diameter, diaLink = 10.0 mm, Link Spacing, SvLink = 75.0 mm
Cover for Shear and Torsion Design from Concrete Surface to Main Bar Surface = 35 mm

Shear And Torsion Calculation in X-X Axis


Section Width, Bx = 900.0 mm, Section Height, Hx = 300.0 mm
Section Effective Depth, dx = Hx - Cover(including link) - diaMain / 2 = 699.0 mm

Link Horizontal Dimension, h1 = b - 2 × Side Cover - DiaLink = 900 - 2 × 25 - 10 = 840 mm


Link Vertical Dimension, v1 = h - 2 × Cover - DiaLink = 300 - 2 × 25 - 10 = 690 mm
Dimension x1 = Min (h1, v1) = 690 mm, y1 = Max (h1, v1) = 840 mm

Section Dimension: Dmin = 300.0 mm, Dmax = 900.0 mm


Torsion Stress, νst = 2 × T × 106 / (Dmin² × (Dmax - Dmin / 3)) = 0.00 N/mm²
License Number: Timer-SN111-C0-1
7/8
Effective depth, d = 699.0 mm
Shear Stress, νss = V × 1000 / (b × d) = 148.2 × 1000 / (900.0 × 699.0) = 0.24 N/mm²

Part 2 : Clause 2.4.6 and Table 2.3


Maximum Combined Stress Allowed, νtu = Min (0.8 × √fcu, 5) = 4.38 N/mm²
Total Stress, νTot = νss + νst = 0.24 + 0.00 = 0.24 N/mm² ≤ νtu (4.38 N/mm²)
Checking for Combined Stress Allowed Pass

Clause 3.8.4.6
Shear and torsion not check due to M / N and shear stress for all load cases not exceeding the limit

Shear And Torsion Calculation in Y-Y Axis


Section Width, By = 300.0 mm, Section Height, Hy = 900.0 mm
Section Effective Depth, dy = Hy - Cover(including link) - diaMain / 2 = 849.0 mm

Link Horizontal Dimension, h1 = b - 2 × Side Cover - DiaLink = 300 - 2 × 25 - 10 = 690 mm


Link Vertical Dimension, v1 = h - 2 × Cover - DiaLink = 900 - 2 × 25 - 10 = 840 mm
Dimension x1 = Min (h1, v1) = 690 mm, y1 = Max (h1, v1) = 840 mm

Section Dimension: Dmin = 300.0 mm, Dmax = 900.0 mm


Torsion Stress, νst = 2 × T × 106 / (Dmin² × (Dmax - Dmin / 3)) = 0.00 N/mm²
Effective depth, d = 849.0 mm
Shear Stress, νss = V × 1000 / (b × d) = 128.5 × 1000 / (300.0 × 849.0) = 0.20 N/mm²

Part 2 : Clause 2.4.6 and Table 2.3


Maximum Combined Stress Allowed, νtu = Min (0.8 × √fcu, 5) = 4.38 N/mm²
Total Stress, νTot = νss + νst = 0.20 + 0.00 = 0.20 N/mm² ≤ νtu (4.38 N/mm²)
Checking for Combined Stress Allowed Pass

Clause 3.8.4.6
Shear and torsion not check due to M / N and shear stress for all load cases not exceeding the limit

Column Buckling Check


Minimum dimension within member = 300 mm
Link spacing allowed = 12 × Compression bar diameter = 12 × 32 = 384 mm or 75 mm whichever lesser
Maximum link spacing allowed = 75 mm

Minimum column dimension to have minimum link diameter = 225 mm


Smallest column sectional dimension (or equivalent) = 300 mm > 225 mm
Minimum link diameter required corresponding to main bar = 0.25 × 32 = 8.0 mm
Link diameter selected = 10 mm >= 8.0 mm
Link Provided T10 - 75, Internal Hook Provided 6T10 - 75

License Number: Timer-SN111-C0-1


8/8

You might also like