Data Sheet

HERSIC Mono PERC PV Module HERSIC-530W-H144M


10BB HALF-CELL By:

ZXM7SP144-530/M

ELECTRICAL DATA

10 Maximum Power
*STC
530W
*NMOT
396.30W

Op�mum Power Voltage 41.00 38.20V

Op�mum Opera�ng Current 12.94 10.39A

Open Circuit Voltage 49.30V 46.10V

Short Circuit Current 13.66A 11.03A

Module Efficiency 20.74%


Graphene
Coated Tolerance Wa�age 0-3%

NOCT 44°C ±2°C


*STC (Standard Test Condi�on): Irradiance 1000W/㎡, Module Temperature 25℃, AM 1.5
*NMOT(Nominal module opera�ng temperature):Irradiance 800W/㎡,Ambient Temperature 20℃,AM 1.5,Wind Speed 1m/s
SELF CLEANING
Solar panel
TEMPERATURE COEFFICIENTS
25 YEARS Temperature coefficient of Pmax -0.35%/°C

Temperature coefficient of Voc -0.29%/°C

TTemperature coefficient of IscV 0.05%/°C

12 YEARS

COMPONENTS & MECHANICAL DATA


Cell (material / Dimensions) Mono PERC

BENEFITS Number of Cell(pcs) 144(6×24)

Size of Module ( L / H / W) 2256×1133×40 mm(With Frame)

Glass 3.2mm, High Transmission

AR Coated Tempered Glass

Weight Per Piece 28.5 kg

Modules sorted by High Efficiency Stable Power Junc�on Box (Protec�on degree) ≥IP68, 3 diodes
current, op�mizing
system power Cable & Connector Type 4 mm² , 350 mm & MC4-compa�ble
genera�on.
Maximum load(snow/wind) 5400 Pa / 2400 Pa

Opera�ng temperature range -40°C to 85°C

Maximum series fuse 25A

Max. system voltage 1500 V DC

Low Carbon Emission Excellent Weather


Resistance

Adress: 400 Applewood Crescent, Suite 100,


Vaughan, ON, L4K 0C3, Canada.
Toll Free: (888)-383-7329
E-mail: info@hersic.com www.hersic.com
Data Sheet

HERSIC Mono PERC PV Module HERSIC-530W-H144M


10BB HALF-CELL By:

ZXM7SP144-530/M
I-V CURVES OF PV MODULE(530W)
PACKING
16

Cells temp. = 25 ° C
14 Incident Irrad. = 1000 W/m²

12
Incident Irrad. = 800 W/m²

10
Pieces per box 27 pcs
Current [A]

Incident Irrad. = 600 W/m²


8

6 Incident Irrad. = 400 W/m²


Pieces per container 40’HQ 540
4
Incident Irrad. = 200 W/m²

0
0 10 20 30 40 50 60

Voltage [V]

WARRANTY
P-V CURVES OF PV MODULE(530W) POWER WARRANTY PRODUCT WARRANTY
600

Cells temp. = 25 ° C 25 0.55% Annual Degradation over 25 years 12


500
Incident Irrad. = 1000 W/m²
Incident Irrad. = 800 W/m²
Product Warranty
Incident Irrad. = 600 W/m²
Incident Irrad. = 400 W/m²
Incident Irrad. = 200 W/m²
400

12 Material & Workmanship Warranty


Power [W]

300

200

100

Hersic’s Standard Reliable Series


Warranted Power Output

0
0 10 20 30 40 50 60 100%
97.5%
Voltage [V] Industry Standard

90%
ENGINEERING DRAWINGS +19.3
84.3%
5%
80%
Barcode 1

1 5 10 15 25
Years
Drainage holes
Barcode 2

Label

FEATURES
Mounting holes

Good low-light performance


Excellent performance under low-light environments
High efficiency
Junction box
Dense bus bars shorten the current conduc�on distances between bars and
lower serial resistance; increases 7-8W power output.
High efficiency
Collected more current, almost no power genera�on efficiency loses by internal
cells cracked.
Grounding holes
Grounding
identification
Improve reliability
improve product reliability; minimize the probability of pressure and ba�ery
fragmenta�on caused by thermal stress.

Back View Front View Longer life time


Minimize the heat resistance due to internal cracks, bringing
longer life span and less a�enua�on.

CERTIFICATIONS
IEC 61215, IEC 61730, CE, IEC 62804 (PID Fre), UL 1703, J-PEC, PV CYCLE
IEC/EN 61701, IEC 62716
©2019 HERSIC INTERNATIONAL. All rights reserved.
Specifications included in this datasheet are subject to change without notice.
Version 2.2 - Nov 01 - 2019

Adress: 400 Applewood Crescent, Suite 100,


Vaughan, ON, L4K 0C3, Canada.
Toll Free: (888)-383-7329
E-mail: info@hersic.com www.hersic.com

You might also like