I. TECHNICAL DATA

CP

CP

Concrete Forms Specialist in Indonesia since 1985


Project : No Offer :

TOL KAPAL BETUNG – -


PIER HEAD JEJAWI
Subject : Sheet no :
PD 8 Static Calculation 2 of 6
Area : Date : Rev :
- November 21, 2018 00

II. MATERIAL PROPERTIES

GIRDER GT 24 :

b 8 cm
Ax 24 cm2
Ix 8000 cm4
Wx 700 cm3
Sx 525 cm3
Δ max L/500
E 100,000 kg/cm2
σ ijin 70000 kg.cm2
τ ijin 1400 kg

STEEL WALER SRZ :

b 15.2 cm
Ax 23 cm2
Ix 372 cm4
Wx 74 cm3
Sx 43.38 cm3
Δ max L/400
E 2,100,000 kg/cm2
σ ijin 1,600 kg/cm2
τ ijin 928 kg/cm2

III. LOAD CALCULATION

Pembebanan :

Concrete Area
Concrete + ML : 2,500 kg/m3 x 3.85 m x 107.5% = 10346.8 kg/m2
Live Load : 100 kg/m2 = 100 kg/m2
Formwork : 100 kg/m2 = 100 kg/m2 +
Total = 10546.8 kg/m2

Concrete Forms Specialist in Indonesia since 1985


Project : No Offer :

TOL KAPAL BETUNG – -


PIER HEAD JEJAWI
Subject : Sheet no :
PD 8 Static Calculation 3 of 6
Area : Date : Rev :
- November 21, 2018 00

IV. STRUCTURE ANALYSIS

KONTROL GIRDER

Beban Max:
Jarak antar girder 25cm = 0.25m
q = 10546.8 kg/m2 x 0.25 m = 2636.7 kg/m
Based on STAAD.Pro 2004 calculation :

LOAD

BENDING MOMENT

SHEAR

DISPLACEMENT

Concrete Forms Specialist in Indonesia since 1985


Project : No Offer :

TOL KAPAL BETUNG – -


PIER HEAD JEJAWI
Subject : Sheet no :
PD 8 Static Calculation 4 of 6
Area : Date : Rev :
- November 21, 2018 00

Mmax = 15,999 kg-cm Dmax = 989 kg Dmax = 0.122 mm

σmax = Mmax = 15,999 kg.cm < 70,000 kg/cm … -ok-

τmax = Dmax = 989 kg < 1,400 kg … -ok-

Dmax = = 0.12 mm < 0.72 mm … -ok-

Concrete Forms Specialist in Indonesia since 1985


Project : No Offer :

TOL KAPAL BETUNG – -


PIER HEAD JEJAWI
Subject : Sheet no :
PD 8 Static Calculation 5 of 6
Area : Date : Rev :
- November 21, 2018 00

KONTROL STEEL WALER

Reaction from girder to steel waler, P max = 1978 kg

Based on STAAD.Pro 2004 calculation :

LOAD

BENDING MOMENT

SHEAR FORCE

DISPLACEMENT

Concrete Forms Specialist in Indonesia since 1985


Project : No Offer :

TOL KAPAL BETUNG – -


PIER HEAD JEJAWI
Subject : Sheet no :
PD 8 Static Calculation 6 of 6
Area : Date : Rev :
- November 21, 2018 00

Mmax = 72,599 kg-cm Dmax = 6,214 kg Dmax = 1.291 mm

Mmax 72599.15 kg-cm


σmax = = = 976.06 kg/cm2 < 1,600 kg/cm2 … -ok-
W 74.38 cm3
Dmax × S 6214.466 kg × 43.38 cm2
τmax = = = 805.21 kg/cm2 < 928 kg/cm2 … -ok-
I×b 372 cm4 × 0.9 cm
Dmax = = 1.29 mm < 5.98 mm … -ok-

KONTROL SHORING PD 8

Based on STAAD.Pro 2004 calculation :

P max = 7813.246 kg < allowable PD 8, 8000 kg/leg,…........………………………………..OK