You are on page 1of 7

Beta Tester for IES, Inc.

F-4
PROPOSED 2 STOREY RESIDENCE. KIBUNGAN, BENGUET. (DAO-ANIS)

Design Detail
Y

300 mm
X

300 mm 1.6 m

X Bars: 6 - #5 (@ ~286.3 mm)


Z Bars: 6 - #5 (@ ~286.3 mm)

Z Z
1.6 m

1.6 m
Y X

Check Summary 1.6 m Criteria


Ratio Check Provided Required Combination
----- Footing ----- Building Code IBC 2009
0.788 X Flexure (-Z) 57.82 kN·m 45.53 kN·m Strength Load Combinations IBC 2009 (Strength)
0.788 X Flexure (+Z) 57.82 kN·m 45.53 kN·m Stability Load Combinations ASCE 7-05 (ASD)
0.849 Z Flexure (-X) 62.55 kN·m 53.11 kN·m Allowable Bearing Pressure 165 kPa
0.849 Z Flexure (+X) 62.55 kN·m 53.11 kN·m Gross / Net Net
0.547 Shear (-Z) 181.3 kN 99.08 kN Overturning F.S. 1.50
0.547 Shear (+Z) 181.3 kN 99.08 kN Sliding F.S. 1.50
0.547 Shear (-X) 195.7 kN 107 kN Uplift F.S. 1.50
0.547 Shear (+X) 195.7 kN 107 kN Additional Uplift Resistance 0 kN
0.800 Min Steel Z 1200 mm² 960 mm² Friction Coefficient 0.40
0.800 Min Steel X 1200 mm² 960 mm² Passive Soil Resistance 0 kN
0.099 Min Strain Z 0.0403 0.0040 Concrete Weight 23.56 kN/m³
0.091 Min Strain X 0.0438 0.0040 Parme beta (for biaxial) 0.65
0.702 Punching Shear 1.13 MPa 0.79 MPa Include footing weight in strength bearing pressure Yes
----- Stability ----- Include overburden in strength bearing pressure Yes
0.883 Bearing Pressure 165 kPa 145.7 kPa
0.000 Overturning-X Infinite 1.500
0.000 Overturning-Z Infinite 1.500
0.000 Sliding-X Infinite 1.500
0.000 Sliding-Z Infinite 1.500
0.000 Uplift Infinite 1.500

Loads Summary (Prefactored Loads)


Load Set Combination Type P Mx Mz Vx Vz Overburden
New Load Set Strength 373 kN 0 kN·m 0 kN·m 0 kN 0 kN 0 kPa
New Load Set Stability 373 kN 0 kN·m 0 kN·m 0 kN 0 kN 0 kPa

QuickFooting 2.0 (iesweb.com) Page 1 of 7 Thursday 08/19/21 3:21 PM


Beta Tester for IES, Inc. F-4
PROPOSED 2 STOREY RESIDENCE. KIBUNGAN, BENGUET. (DAO-ANIS)

Capacity Calcs
Footing X-Direction Capacity

General Section Calcs (ACI 318-08 10.2.7)


As fy 1200 mm² 275.8 MPa
a= = = 11.76 mm
0.85 F'c bw 0.85 20.69 MPa 1600 mm
1 = 0.85 F'c  4000 psi
x = a / 1 = 11.76 mm / 0.85 = 13.84 mm
Capacity Calcs (ACI 318-08 10.2, 11.2.1.1, 10.5.4, 7.12.2.1, 10.3 )
Mn =  As fy d - a / 2 = 0.90 1200 mm² 275.8 MPa 215.9 mm - 11.76 mm / 2 = 62.55 kN·m

Vc =  2  F'c bw d = 0.75 2 1.0 20.69 MPa 1600 mm 215.9 mm = 195.7 kN


Y
Asmin = 0.002 Ag = 0.002 5.17 ft² = 960 mm²
300 mm

Z d 215.9 mm
t = 0.003 -1 = 0.003 -1 = 0.04
x 13.84 mm
Development (ACI 318-08 12.2)
1.6 m
t = 1.0 less than 12 inches cast below
e = 1.0 bar not epoxy coated
s = 0.80 bars are #6 or smaller
 = 1.0 normal weight concrete
c = 84.14 mm lesser of half spacing, ctr to surface
Ktr = 0.0 no transverse reinforcement
3. fy t e s 3. 275.8 MPa 1.0 1.0 0.80
ld = db = 15.88 mm = 27.82 cm
40 2.5 40 2.5
 F'c 1.0 20.69 MPa

Footing Z-Direction Capacity

General Section Calcs (ACI 318-08 10.2.7)


As fy 1200 mm² 275.8 MPa
a= = = 11.76 mm
0.85 F'c bw 0.85 20.69 MPa 1600 mm
1 = 0.85 F'c  4000 psi
x = a / 1 = 11.76 mm / 0.85 = 13.84 mm
Capacity Calcs (ACI 318-08 10.2, 11.2.1.1, 10.5.4, 7.12.2.1, 10.3 )
Mn =  As fy d - a / 2 = 0.90 1200 mm² 275.8 MPa 200 mm - 11.76 mm / 2 = 57.82 kN·m

Vc =  2  F'c bw d = 0.75 2 1.0 20.69 MPa 1600 mm 200 mm = 181.3 kN


Y
Asmin = 0.002 Ag = 0.002 5.17 ft² = 960 mm²
300 mm

X d 200 mm
t = 0.003 -1 = 0.003 -1 = 0.04
x 13.84 mm
Development (ACI 318-08 12.2)
1.6 m
t = 1.0 less than 12 inches cast below
e = 1.0 bar not epoxy coated
s = 0.80 bars are #6 or smaller
 = 1.0 normal weight concrete
c = 100 mm lesser of half spacing, ctr to surface
Ktr = 0.0 no transverse reinforcement
3. fy t e s 3. 275.8 MPa 1.0 1.0 0.80
ld = db = 15.88 mm = 27.82 cm
40 2.5 40 2.5
 F'c 1.0 20.69 MPa

QuickFooting 2.0 (iesweb.com) Page 2 of 7 Thursday 08/19/21 3:21 PM


Beta Tester for IES, Inc. F-4
PROPOSED 2 STOREY RESIDENCE. KIBUNGAN, BENGUET. (DAO-ANIS)

Capacity Calcs (continued)


Footing Punching Shear Capacity

Punching Shear (ACI 318-08 11.11.1.2, 11.11.2.1 )


bo = 2032 mm perimeter of critical section
 = 1.40 column width ratio
s = 40.0 interior column
 = 1.0 normal weight concrete
4 4
a Vc = 2 +  F'c bo d = 2+ 1.0 20.69 MPa 2032 mm 207.9 mm = 774.9 kN
457.9 mm  1.40
s d 40.0 207.9 mm
b Vc = + 2  F'c bo d = +2 1.0 20.69 MPa 2032 mm 207.9 mm = 972.2 kN
bo 2032 mm
Z
557.9 mm

c Vc = 4  F'c bo d = 4 1.0 20.69 MPa 2032 mm 207.9 mm = 638.1 kN


1.6 m

X Vn =  Vc = 0.75 638.1 kN = 478.6 kN


vn = Vn / bo d = 478.6 kN / 2032 mm 207.9 mm = 1.13 MPa
Values needed for check ( ACI 318-08 11.11.6.1, R11.11.6.1, eqn 13-1, R11.11.6.2 )
1 1
vx = 1 - = 1- = 0.42
2 bz 2 557.9 mm
1+ 1+
3. bx 3. 457.9 mm
1 1
vz = 1 - = 1- = 0.38
2 bx 2 457.9 mm
1+ 1+
1.6 m 3. bz 3. 557.9 mm
Jx = 21673395008 mm ^ 4 calculated from ACI R11.12.6.2
Jz = 16176699981 mm ^ 4 calculated from ACI R11.12.6.2

QuickFooting 2.0 (iesweb.com) Page 3 of 7 Thursday 08/19/21 3:21 PM


Beta Tester for IES, Inc. F-4
PROPOSED 2 STOREY RESIDENCE. KIBUNGAN, BENGUET. (DAO-ANIS)

Strength Checks [Load Set: New Load Set Combination: ]


Factored Loads Reinforcement Limits
Axial Force 373 kN
Moment X 0 kN·m
Moment Z 0 kN·m
Shear X 0 kN
145.7 kPa 145.7 kPa Min Steel Check (ACI 318-08 Ch
Shear Z 0 kN
Overburden 0 kPa As = 1200 mm²  Asmin = 960 mm² 
Footing Weight 0 kN
Z Resultant = 373 kN (factored) Min Steel Check (ACI 318-08 Ch
Pedestal Weight 0 kN
X
As = 1200 mm²  Asmin = 960 mm² 
Min Strain Check (ACI 318-08 Ch
t = 0.04  tmin = 0.0 
Min Strain Check (ACI 318-08 Ch
145.7 kPa 145.7 kPa
Max pressure (factored) = 145.7 kPa
t = 0.04  tmin = 0.0 
(Includes effects of overburden and footing weight)

Footing Flexure

145.7 kN 157.4 kN
Z-Flexure (+X side)
Mz1 = Rz1 dz1 = 157.4 kN 337.5 mm = 53.11 kN·m
Mn = 62.55 kN·m  Mu = 53.11 kN·m 
Z-Flexure (-X side)
Z Z Mz2 = Rz2 dz2 = 157.4 kN 337.5 mm = 53.11 kN·m

X X
Mn = 62.55 kN·m  Mu = 53.11 kN·m 
X-Flexure (+Z side)
Mx1 = Rx1 dx1 = 145.7 kN 312.5 mm = 45.53 kN·m
Mn = 57.82 kN·m  Mu = 45.53 kN·m 
X-Flexure (-Z side)
Mx2 = Rx2 dx2 = 145.7 kN 312.5 mm = 45.53 kN·m
145.7 kN 157.4 kN Mn = 57.82 kN·m  Mu = 45.53 kN·m 

Footing Shear

99.08 kN 107 kN
Shear (+X side)
Vx2 = Rx4 = 107 kN = 107 kN
Vn = 195.7 kN  Vu = 107 kN 
Shear (-X side)
Z Z Vx1 = Rx3 = 107 kN = 107 kN

X X
Vn = 195.7 kN  Vu = 107 kN 
Shear (+Z side)
Vz2 = Rz4 = 99.08 kN = 99.08 kN
Vn = 181.3 kN  Vu = 99.08 kN 
Shear (-Z side)
Vz1 = Rz3 = 99.08 kN = 99.08 kN
99.08 kN 107 kN Vn = 181.3 kN  Vu = 99.08 kN 

QuickFooting 2.0 (iesweb.com) Page 4 of 7 Thursday 08/19/21 3:21 PM


Beta Tester for IES, Inc. F-4
PROPOSED 2 STOREY RESIDENCE. KIBUNGAN, BENGUET. (DAO-ANIS)

Strength Checks [Load Set: New Load Set Combination: ] (continued)


Footing Punching Shear

Punching Shear Check (ACI 318-08 Ch 11.12.1.2, 11.11.2.1)


Ppunching = Ptotal + Wp - Pperimeter = 373 kN + 0 kN - 37.23 kN = 335.8 kN
Z
V  M e  M e
vu = u + vx ux z + vz uz x
X bo d Jx Jz
335.8 kN 0.42 0 kN·m 279 mm 0.38 0 kN·m 229 mm
= + +
2032 mm 207.9 mm 21673395008 mm ^ 4 16176699981 mm ^ 4
= 0.79 MPa

37.23 kN vn = 1.13 MPa  vu = 0.79 MPa 

QuickFooting 2.0 (iesweb.com) Page 5 of 7 Thursday 08/19/21 3:21 PM


Beta Tester for IES, Inc. F-4
PROPOSED 2 STOREY RESIDENCE. KIBUNGAN, BENGUET. (DAO-ANIS)

Stability Checks [Load Set: New Load Set Combination: ]


Forces
Factored Loads
Axial Force 373 kN
Moment X 0 kN·m
Moment Z 0 kN·m
Shear X 0 kN
145.7 kPa 145.7 kPa
Shear Z 0 kN
Overburden 0 kPa
Footing Weight 0 kN
Pedestal Weight 0 kN Z Resultant = 373 kN
Bearing Pressure
X
qallow = 165 kPa  qnet = 145.7 kPa 

145.7 kPa 145.7 kPa


Max pressure = 145.7 kPa
(Net: Does NOT include effects of footing weight or overburden)

Overturning

Overturning
0.8 m

Wf = 0 kN weight of footing

0.8 m 0.8 m Wp = 0 kN weight of pedestal


Fob = qoverburden Aftg - Aped = 0 kPa 27.56 ft² - 0.94 ft² = 0 kN
0.8 m

F.S. against overturning about X axis is infinite no applied moment


F.S. against overturning about Z axis is infinite no applied moment

Sliding

Sliding

Z Wf = 0 kN weight of footing
Wp = 0 kN weight of pedestal
X Fob = qoverburden Aftg - Aped = 0 kPa 27.56 ft² - 0.94 ft² = 0 kN
Fresist = Cf Wf + Wp + Fob + P + Fpassive = 0.40 0 kN + 0 kN + 0 kN + 373 kN + 0 kN = 149.2 kN
F.S. against sliding in X direction is infinite no applied force
F.S. against sliding in Z direction is infinite no applied force

QuickFooting 2.0 (iesweb.com) Page 6 of 7 Thursday 08/19/21 3:21 PM


Beta Tester for IES, Inc. F-4
PROPOSED 2 STOREY RESIDENCE. KIBUNGAN, BENGUET. (DAO-ANIS)

Stability Checks [Load Set: New Load Set Combination: ] (continued)


Uplift

Y
Uplift
X P = 373 kN
F.S. against uplift is infinite axial force is in compression

QuickFooting 2.0 (iesweb.com) Page 7 of 7 Thursday 08/19/21 3:21 PM