Common Alarm list used by NML150 - 10011

No. Description Type What to do Function

2 Sys2 - Reference run done, machine ready to start 22 Machine ready to start. Sys2
3 Sys2 - One or more axis need to be homed - Home manually 21 Sys2
4 Sys2 - Homing failed - Check and restart homing 18 Sys2
5 Sys2 - Incorrect machine mode - De-select current mode 18 Sys2

6 Sys2 - Motor positions not initialized - Close doors and reset EM stop to initialize positions 18 Sys2
7 Sys8 - Door open in different zone than selected 18 Sys8
8 Sys8 - Jog handle connected to different zone than selected 18 Sys8
9 Sys2 - Stop button pressed 22 Stop button have been pressed by operator. Sys2
10 Sys2 - Start button pressed 22 Start button have been pressed by operator. Sys2
In not possible to reset when no EM are active then check
11 Sys2 - Safety circuit stop - Enable Low 2 electrical circuit for Mains contactor. Sys2
12 Sys9 - Emergency stop machine, button no. {0} 17 Reset all the emergency stop buttons before restart. Sys9
13 Sys9 - Emergency stop line, or circuit broken 17 Reset all the emergency stop buttons before restart. Sys9
14 Sys2 - Wait for main pressure valve 22 Sys2
15 Sys2 - Main program not executing - Check setting and restart controller 18 Sys2
16 Sys2 - Format not active - Activate or select another format 18 Sys2
17

18 Sys8 - Open door {0} 2 Close the door. Check the door contact if the error remains. Sys8
19 Sys6 - Machine serial number saved 22 Sys6
20 Sys6 - Machine serial number restored 22 Sys6

21 Sys8 - Open door {0} 2 Close the door. Check the door contact if the error remains. Sys8

22 Sys8 - Open door {0} 2 Close the door. Check the door contact if the error remains. Sys8
23 Sys8 - Laser scanner activated {0} 18 Clear the area in front of the scanner Sys8
24 Sys8 - Robot area machine stop 2 Reset machine stop in robot area Sys8
25 Sys8 - Safety relay de-energized or Emergency stop active 2 Open door and close again or reset EM stop Sys8
Common Alarm list used by NML150 - 10011
No. Description Type What to do Function
26 Sys8 - Door safety relay de-energized 2 Open door and close again. Sys8
27 F1.12 - DC voltage missing, check no. {0} 18 Check the fuses for the DC voltage transformers. Fun1.12
28 F1.15 - Low air pressure, check no. {0} 24 Check the air supply. Fun1.15
29 F1.13 - Central lubrication unit, low pressure 18 Check the pressure in the Central lubrication unit Fun1.13
30 F1.13 - Central lubrication unit, low oil level 24 Check the oil level in the Central lubrication unit Fun1.13
31 F1.13 - Central lubrication unit, low oil level 20 Check the oil level in the Central lubrication unit Fun1.13
32 F1.17 - Energy save active 22 Energy save function running Fun1.17
33 F1.17 - Disable Energy save before machine start 18 Fun1.17
34 F1.17 - Energy save started by machine stop timeout 22 Fun1.17
35 F1.17 - Energy save activated by external device 22 Fun1.17
36 Sys8 - Reset open door 18 Push manual reset button Sys8
Machine will stop within 10 min. Check doors closed to electrical
cabinet and setpoint of the sensor. Check filter or cooling unit in
37 F1.23 - High temp in electrical cabinet 21 cabinet. Fun1.23
Check doors closed to electrical cabinet and setpoint of the
38 F1.23 - High temp in electrical cabinet 18 sensor. Check filter or cooling unit in cabinet. Fun1.23
39 F3.10 - Product detect sensor error 18 Check sensor for dirt, test functionality NM Fun3.10 / NP Fun3.10
40 Sys2 - Stop button pressed when trying to start 18 Check stop button(s) Sys2
41 F1.22 - Vacuum too low, unit no. {0} 18 Check vacuum pumps or ejectors Fun 1.22
42 Sys2 - Starting 22 Machine starting. Sys2
43 F1.19 - Weekly service interval 21 The machine is close to the time for service interval. Fun01.19
44 F1.19 - Weekly service interval 18 Time for service interval of the machine. Fun01.19
45 Sys2 - Reference run timeout - Check and restart 18 Sys2
46 F1.13 - Central lubrication unit, low pressure in zone {0} 18 Check the pressure in the Central lubrication unit Fun1.13
47
48
49 Sys11 - UPS battery failure 18 Check for failure of the UPS battery. Sys11
50 Sys13 - Alarm statistics error 21 Call Norden for assistance! Sys13
51 Sys13 - Batch finished 18 Set a new batch. Sys13
Common Alarm list used by NML150 - 10011
No. Description Type What to do Function
52 Sys6 - Motor positions restored from file - Verify motor positions before start 18 Check motor positions. Sys6
53 Sys6 - Read persistent variable error 18 Call Norden for assistance! Sys6
54 Sys6 - Write persistent variable error 18 Call Norden for assistance! Sys6
55 Sys2 - Write encoder not possible, error state active 18 Reset Alarm Sys2

Turn the main power off-on. Wait for the system to boot. Reset the
errors and press the Start button for homing. Contact Norden if the
56 Sys6 - Write file error 18 error remains. Possible cause is flash memory failure. Sys6

Turn the main power off-on. Wait for the system to boot. Reset the
errors and press the Start button for homing. Contact Norden if the
57 Sys6 - Read file error 18 error remains. Possible cause is flash memory failure. Sys6
58 Sys6 - Format settings saved 22 Information during processing. Sys6
59 Sys6 - Format settings restored 22 " Sys6
60 Sys6 - System settings saved 22 " Sys6
61 Sys6 - System settings restored 22 " Sys6
62
63
64 Sys6 - Machine status saved 22 " Sys6
65 Sys6 - Machine status restored 22 " Sys6
NM Fun2.10 / NP Fun4.21
66 General error, robot no. {0} 18 Check the robot teach pendant display for further error information / NTP Fun4.10

NM: Manually remove the tubes from the robot tool. Remove the NM Fun2.10 / NP Fun4.21
67 NM: Tubes on tool, robot no. {0} 18 box from the box table if the tubes are in disorder. / NTP Fun4.10
NM Fun2.10 / NP Fun4.21
68 Tool ID and format mismatch, robot no. {0} 18 Change the robot tool or select another format. / NTP Fun4.10
Check the existance of the robot format for the entered format NM Fun2.10 / NP Fun4.21
69 Format error, robot no. {0} 18 number. / NTP Fun4.10
Note the circumstances, take a backup of the robot and contact NM Fun2.10 / NP Fun4.21
70 Program error, robot no. {0} 18 Norden. / NTP Fun4.10
Common Alarm list used by NML150 - 10011
No. Description Type What to do Function
Reset the emergency stops of the robot. Press the white button on
the front of the robot cabinet once after reset of the emergency NM Fun2.10 / NP Fun4.21
71 EM stop error, robot no. {0} 2 stops. / NTP Fun4.10
NM Fun2.10 / NP Fun4.21
72 Incorrect position, robot no. {0} - Reset manually 18 Refer to the Norden robot manual how to correct the error. / NTP Fun4.10
NM Fun2.10 / NP Fun4.21
73 Home positioning failed, robot no. {0} 18 Reset the error. Press the Start button for homing. / NTP Fun4.10
Place the teach box in its holder. Check the function of the NM Fun2.10 / NP Fun4.21
74 Teachbox not in position 25 contact. / NTP Fun4.10
NM Fun2.10 / NP Fun4.21
75 Key switch in manual position 25 Turn the Robot key switch to "PRODUCTION" position. / NTP Fun4.10
76 F1.19 - Monthly service interval 21 The machine is close to the time for service interval. Fun01.19
77 F1.19 - Monthly service interval 18 Time for service interval of the machine. Fun01.19
78 F1.19 - Yearly service interval 21 The machine is close to the time for service interval. Fun01.19
79 18
80 F1.19 - Yearly service interval 18 Time for service interval of the machine. Fun01.19
81 Sys7 - CAN bus communication error, CPX unit no. {0} 18 Check CAN Bus network. Sys7
82 Sys7 - Ethernet/IP bus communication error, scanner no. {0} 18 Check Ethernet/IP Bus network. Sys7
83 Sys7 - Ethernet/IP bus communication error, robot no. {0} 18 Check Ethernet/IP Bus network. Sys7
84 Sys7 - Ethernet/IP bus communication error, vision camera no. {0} 18 Check Ethernet/IP Bus network. Sys7
85
86 Sys2 - Start ISA 88 communication before machine start 18 Check communication to Business system Sys2
87 Sys2 - Watchdog ISA 88 communication 21 Check communication to Business system Sys2
Error when writing filerecord, i.e length of record doesnt match
88 Sys6 - Error write filerecord {0} 18 actual length Sys6

89 Sys6 - Error read filerecord {0} 18 Found record but no function for reading or checksum error Sys6
90 Sys2 - ISA interface data error 18 FB Datamanager error. Contact Norden Sys2
91 F8.11 - Obstruction at outlet zone 28 Check the outlet zone. Fun8.11
92 F8.11 - Downstream machine not ready 28 Downstream machine stopped not ready Fun8.11
93 F8.11 - Obstruction at outlet zone 27 Check the outlet zone. Fun8.11
Common Alarm list used by NML150 - 10011
No. Description Type What to do Function
94 F8.11 - Downstream machine not ready 27 Downstream machine stopped not ready Fun8.11
95
96
97
98
99
100 Customer alarm 1
101 Customer alarm 2
102 Customer alarm 3
103 Customer alarm 4
104 Customer alarm 5
105 Customer alarm 6
106 Customer alarm 7
107 Customer alarm 8
108 Customer alarm 9
109 Customer alarm 10
110 Customer alarm 11
111 Customer alarm 12
112 Customer alarm 13
113 Customer alarm 14
114 Customer alarm 15
115 Customer alarm 16
116 Customer alarm 17
117 Customer alarm 18
118 Customer alarm 19
119 Customer alarm 20
120 Customer alarm 21
Common Alarm list used by NML150 - 10011
No. Description Type What to do Function
121 Customer alarm 22
122 Customer alarm 23
123 Customer alarm 24
124 Customer alarm 25
125 Customer alarm 26
126 Customer alarm 27
127 Customer alarm 28
128 Customer alarm 29
129 Customer alarm 30
130 Customer alarm 31
131 Customer alarm 32
132 Customer alarm 33
133 Customer alarm 34
134 Customer alarm 35
135 Customer alarm 36
136 Customer alarm 37
137 Customer alarm 38
138 Customer alarm 39
139 Customer alarm 40
140 Customer alarm 41
141 Customer alarm 42
142 Customer alarm 43
143 Customer alarm 44
144 Customer alarm 45
145 Customer alarm 46
146 Customer alarm 47
147 Customer alarm 48
Common Alarm list used by NML150 - 10011
No. Description Type What to do Function
148 Customer alarm 49
149 Customer alarm 50
150
151
152
153
154
155 F1.21 - Main shaft motor overload 17 Fun1.21
156 F1.22 - Zero pulse missing encoder 17 Fun1.22
157 F1.22 - Pulse missing encoder 17 Fun1.22
158
159
160
161
162
163 F1.24 - Sensor check error at XGP no. {0} 18 Check the sensor connected at stated XGP number. Fun1.24
164 F1.24 - XGP 1: {0} Fun1.24
165 F1.24 - XGP 2: {0} Fun1.24
166 F1.24 - XGP 3: {0} Fun1.24
167 F1.24 - XGP 4: {0} Fun1.24
168 F1.24 - XGP 5: {0} Fun1.24
169 F1.24 - XGP 6: {0} Fun1.24
170 F1.24 - XGP 7: {0} Fun1.24
171 F1.24 - XGP 8: {0} Fun1.24
172 F1.24 - XGP 9: {0} Fun1.24
173 F1.24 - XGP 10: {0} Fun1.24
174 F1.24 - XGP 11: {0} Fun1.24
Common Alarm list used by NML150 - 10011
No. Description Type What to do Function
175 F1.24 - XGP 12: {0} Fun1.24
176 F1.24 - XGP 13: {0} Fun1.24
177 F1.24 - XGP 14: {0} Fun1.24
178 F1.24 - XGP 15: {0} Fun1.24
179 F1.24 - XGP 16: {0} Fun1.24

Type of alarm:
1 = AsyncStop (NOTE! Will generate GE_ALARM_TYPE_ASYNCSTOPNORDEN in NC)

2 = SyncStopEL (NOTE! Will generate GE_ALARM_TYPE_ASYNCSTOPNORDEN in NC)

3 = SyncStopEH (NOTE! Will generate GE_ALARM_TYPE_ASYNCSTOPNORDEN in NC)


4 = StopEndOfCycle
5 = MainsContactorOff
17 = GE_ALARM_TYPE_STOPPOS0
18 = GE_ALARM_TYPE_STOPPOS1
20 = GE_ALARM_TYPE_LOWLEVELWARNING
21 = GE_ALARM_TYPE_WARNING
22 = GE_ALARM_TYPE_INFORMATION
23 = GE_ALARM_TYPE_STOPPOS1AUTORESTART
24 = GE_ALARM_TYPE_LOWLEVELSTOP
25 = GE_ALARM_TYPE_UPSTREAMSTOP
26 = GE_ALARM_TYPE_UPSTREAMSTOPAUTORESTART
27 = GE_ALARM_TYPE_DOWNSTREAMSTOP
28 = GE_ALARM_TYPE_DOWNSTREAMSTOPAUTORESTART
Common Alarm list used by NML150 - 10011
No. Description Type What to do Function
29 = GE_ALARM_TYPE_ASYNCSTOPNORDEN (NOTE! Only for NC)

30 = GE_ALARM_TYPE_SYNCSTOPELNORDEN (NOTE! Only for NC and should only be


used for Alarm 371) (Will generate Alarm type 2 - SyncStopEL when master vel = 0)
Alarm list used by NML150 - 10011
No. Description Type What to do Function
180 F1.20 - UPS running on battery power 21 Fun1.20
181 F1.20 - Mains interrupt 18 Fun1.20
182 F1.20 - UPS general error 18 Fun1.20
183 F1.20 - UPS battery fault 18 Fun1.20
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199 18 Check the sensor position and functionality. Fun4.04

200 F2.01 - Box loading error, robot no. {0} 18 Check for jams or obstruction at box loading positioning system Fun2.01

201 F2.01 - Box rejecting error, robot no. {0} 18 Check for jams or obstruction at box rejecting positioning system Fun2.01
202 F2.01 - Box obstruction error, robot no. {0} 18 Remove box Fun2.01

203 F2.01 - Pusher cylinder cannot reach target position, robot no. {0} 18 Check why pusher cylinders cant perform complete movement Fun2.01
204 F2.01 - Box infeed conveyor error 18 Check for jam at the conveyor Fun2.01
205 F2.01 - Box outfeed conveyor error 18 Check for jam at the conveyor Fun2.01
Alarm list used by NML150 - 10011
No. Description Type What to do Function
Remove tubes from tube holder chain and move the indexing
206 F1.01 - Tube indexing moved manually, all tubes will be faulty marked 18 chain to give free space for mechanical lifts. Fun1.01
207 F1.02 - Main shaft moved manually, all tubes will be faulty marked 18 Remove tubes from tube holder chain Fun1.02
208 F1.02 - Main shaft motor needs new homing, error code {0} 17 Follow instructions in HMI and do a new homing. Fun1.02
209 F2.10 - Low level stop box in conveyor 24 Put boxes with tubes on the infeed conveyor. Fun2.10
Check the box table for jams. Check the sensor for detecting box
210 F2.10 - No box on box-table, robot no. {0} 25 in position. Fun2.10
211 F2.10 - Box change error, robot no. {0} 18 Check for obstruction or jams on the box table. Fun2.10
212 F2.10 - Low level box in conveyor 21 Put boxes with tubes on the infeed conveyor. Fun2.10
Remove all the boxes from the outfeed conveyor. Check the
213 F2.10 - Outfeed conveyor blocked 25 sensor if the error remains. Fun2.10
214 F3.13 - Tube orientation not executed, ch. {0} 18 Fun3.13
215 F3.13 - Tube orientation unit not ready, ch. {0} 18 Check the power supply to the drive stage. Fun3.13
216 F2.10 - Box infeed conveyor motor error RTL 25 Check the infeed conveyor for obstruction. Fun2.10
217 F2.10 - Box outfeed conveyor motor error RTL 25 Check the infeed conveyor for obstruction. Fun2.10
218 Bokad för split av larm 271
219 Bokad för split av larm 271
220 Bokad för split av larm 271
221 F3.01 - Cap lift in low position 2 Check sensor Fun3.01
222 F3.11 - Cap missing on tube, ch. {0} 18 Remove the tube. Check the content in the tube box. Fun3.11
223 F3.11 - Cap sensor failure, ch. {0} 18 Check sensor X Fun3.11
224 F3.12 - Tube damaged or upside down, ch. {0} 18 Remove the tube. Check the content in the tube box. Fun3.12
225 F3.14 - Tube holder not in place at lift, ch. {0} 17 Check the filling station. Check the sensor. Fun3.14
Check the extra lift station if there is a tube holder missing or if
226 F3.14 - Tube holder not in place at extra lift, ch. {0} 17 there is an error with the sensor. Fun3.14
Check the adjustment of the photocell detecting the orientation
227 F3.03 - Tube orientation not executed, ch. {0} 18 mark. Fun3.03
Check the reject and discharge stations for failure in ejecting the
228 F3.16 - Tubes still in chain 18 tubes. Fun3.16
229 F3.18 - Low pressure, gas injection 18 Check sensor Fun3.18
Alarm list used by NML150 - 10011
No. Description Type What to do Function

230 F5.10 - Hopper level, max fill time error, hopper no. {0} 24 Fun 5.10
231 F5.10 - Hopper level, max level error, hopper no. {0} 24 Fun 5.10
232 F5.10 - Hopper level, min level error, hopper no. {0} 24 Fun 5.10
233 F5.11 - Stirring device overload, hopper no. {0} 18 Check status on frequency inverter or motorbreaker. Fun 5.11
Safe torque signal is low should be high. (Set input to 0 if inverter
234 F5.11 - Stirring device, safe torque off, hopper no. {0} 18 broken) Fun 5.11
Safe torque signal i shigh should be low. (Set input to 0 if inverter
235 F5.11 - Stirring device, safe torque on, hopper no. {0} 18 broken) Fun 5.11
236 F5.11 - Stirring device stopped - Restart device 18 Stirring device stopped and needs to be restarted. Fun 5.11
237 F5.12 - High temperature, hopper no. {0} 18 Wait for correct temperature Fun 5.12
238 F5.12 - Low temperature, hopper no. {0} 18 Wait for correct temperature Fun 5.12
239 F5.12 - Temperature sensor error, hopper no. {0} 18 Check connections and sensor Fun 5.12
240 F8.10 - Line connection selected in jog mode 18 Fun8.10
241 F8.10 - Ethernet line communication check, sync quality {0} 18 Fun8.10
242 F8.10 - Line selected on NF but not on NC 18 Fun8.10
243 F8.10 - NC alarm pending 18 Alarm type depends on stop type in NC (17 or 18) Fun8.10
244 F8.10 - NC life bit missing 18 Fun8.10
245 F8.10 - NC not homed 18 Fun8.10
246 F8.10 - Manual infeed is active 22 Fun8.10
247 F7.21 - Tube transport conveyor motor not ready 18 Fun7.21
248 F5.12 - Hopper heating, high water level 18 Check water level Fun 5.12
249 F5.12 - Hopper heating, low water level 18 Check water level Fun 5.12
250 F4.03 - Tilting of filling valves sequence error, error code {0} 18 Check sensors Fun4.03
251 F1.16 - Hand wheel is still on 18 Disengage the handwheel. Fun1.16
Lower the lift manually. If the error remains check that the homing
252 F1.16 - Main lift filling must be lowered manually before main shaft can be moved 18 sensor is activated. Fun1.16
Lower the lift manually. If the error remains check that the homing
253 F1.16 - Extra lift must be lowered manually before main shaft can be moved 18 sensor is activated. Fun1.16

254 F1.10 - Indexing chain overload 17 Check for obstruction or overload of the tube transport chain. Fun1.10
Alarm list used by NML150 - 10011
No. Description Type What to do Function

255 F1.01 - Indexing axis in wrong position - Set zero position 2 One or more axis is out of positon. Fun1.01

256 F5.15 - Incorrect machine position to use hoist device 18 Move machine to a position between 200-280 to enable hoist. Fun5.15
257 F5.15 - Open door to enable hoist, no. {0} 18 Open the door Fun5.15
258 F5.15 - Close door to enable hoist, no. {0} 18 Close the door Fun5.15
259 F5.15 - Hoist device frequency inverter overload 18 Check the hoist motor Fun5.15
Check the coding station for obstruction. Check the mechanical
260 F6.01 - Overload coding station outer, ch. {0} 17 setting of the coding station. Fun6.01
Check the coding station for obstruction. Check the mechanical
261 F6.01 - Overload coding station, ch. {0} 17 setting of the coding station. Fun6.01
Extra cycle after StopPos1 not finished. Increase the machine
262 F6.01 - Finishing cycle error coding station 17 speed. Contact Norden! Fun6.01
Check the coding station for obstruction. Check the mechanical
263 F6.02 - Overload trimming station outer 17 setting of the coding station. Fun6.02
Check the coding station for obstruction. Check the mechanical
264 F6.02 - Overload trimming station 17 setting of the coding station. Fun6.02
265 F6.03 - Screw jack thread worn out, height adjustment sealing beam column 18 Replace with new screw jack. Fun6.03
266 F6.03 - Obstruction error, height adjustment sealing beam column 18 Check for obstruction of the sealing beam column Fun6.03
267 F4.04 - Pump unit not in place, unit {0} 18 Check the sensor position and functionality. Fun4.04
268 F4.04 - Screw jack thread worn out, height adjustment pump column 18 Replace with new screw jack. Fun4.04
269 F4.04 - Obstruction error, height adjustment pump column 18 Check for obstruction of the pump column Fun4.04
270 F4.03 - Nozzle valve check failure, ch. {0} 17 Check the sensor position and functionality. Fun4.03
271 F4.02 - Filling valve check failure, ch. {0} 17 Check the sensor position and functionality. Fun4.02
272 F4.11 - Fill pump 1, piston movement faulty, ch. {0} 17 Check the mechanics of the pump piston. Fun4.11
273 F4.11 - Fill pump 2, piston movement faulty, ch. {0} 17 Check the mechanics of the pump piston. Fun4.11
274 F4.11 - Fill pump 3, piston movement faulty, ch. {0} 17 Check the mechanics of the pump piston. Fun4.11
275 F4.03 - Product pressure is too high for tilting of filling valves 18 Release the product pressure before tilting of filling valves. Fun4.03
276 F6.10 - HA lift check failure, ch. {0} 17 Check the sensor position and functionality. Fun6.10
Reset the error and wait for the temperature to arrive to the correct
277 F6.11 - HA sealing high temp., ch. {0} 18 level. Fun6.11
Alarm list used by NML150 - 10011
No. Description Type What to do Function
Wait for the temperature to arrive to the correct level. Reset error
278 F6.11 - HA sealing low temp., ch. {0} 18 and try again. Fun6.11
279 F6.11 - HA sealing temp. sensor error, ch. {0} 18 Check the sensor and its connections. Fun6.11

280 F6.11 - HA sealing low air flow, ch. {0} 18 Check the air pressure. Check the sensor(s) for the air flow. Fun6.11
281 F6.11 - HA sealing low water flow, ch. {0} 18 Check the water pressure. Fun6.11
Check status on frequency inverter. Check the fan motor for
282 F6.11 - HA fan motor overload, ch. {0} 18 obstruction. Fun6.11
283 F6.11 - Sealing clamps low water flow 18 Check the water pressure. Fun6.11
284 F7.02 - Bulk conveyor in wrong position 18 Check if bulk conveyor in position. Fun7.02
285 F4.03 - Filling valve tilting not in home pos. - Move back before start 18 Move back Filling valve tilting before start! Fun4.03
Check the trimming station for obstruction. Check the mechanical
286 F6.14 - Overload trimming station, sensor no. {0} 17 settings of the trimming station. Fun6.14
287 F6.02 - Trimming lift check failure, ch. {0} 17 Check the sensor position and functionality. Fun6.02
288 F6.05/F6.13 - Overload coding station, ch. {0} 17 Fun6.05, Fun6.13
289 F6.16 - Sealing beam not down 17 Fun6.16
290 F6.05 - Finishing cycle error sealing beam 17 Fun6.05
291 F6.15 - HF welding pulse missing 18 Check HF equipment for errors. Fun6.15
292 F6.15 - HF welding pulse too long 18 Check HF equipment for errors. Fun6.15
293 F6.15 - HF equipment low water flow 18 Check water flow Fun6.15
294 F6.15 - HF equipment not ready for welding 18 Check HF equipment for errors. Fun6.15
295 F6.15 - HF equipment low water flow clamps 18 Check water flow clamps Fun6.15
296 F6.18 - Water cooler not ready 18 Check that the water cooler is turned on. Fun6.18
297 F7.03 - Checkweigher, conveyor not ready 18 Fun7.03
298 F7.03 - Checkweigher, format change error 18 Check the controller of the check weigh system. Restart. Fun7.03
299 F7.03 - Checkweigher not OK 18 Check the controller of the check weigh system. Restart. Fun7.03
300 F7.03 - Weight out of tolerance, ch. {0} 18 Adjust the filling volume. Fun7.03
301 F7.03 - Checkweigher, increase of pump stroke too big, ch. {0} 18 Something is wrong with the feedback functionality. Fun7.03
302 F7.03 - Checkweigher, decrease of pump stroke too big, ch. {0} 18 Something is wrong with the feedback functionality. Fun7.03
Alarm list used by NML150 - 10011
No. Description Type What to do Function
Malfunction in tooling of P&P1 or P&P2. Check sensor
303 F7.03 - Checkweigher, pick and place error 2 functionality. Fun7.03
304 F7.02/F7.20 - Tube transport check in cartoning machine 18 Check for tubes under PnP units Fun7.02, Fun7.20
305 F2.11 - Norden store magazine not ready 18 Check the store magazine. Check the frequency inverter. Fun2.11
306 F2.11/F2.12 - Low level tube infeed 24 Check the infeed shute for obstruction or fill it with tubes. Fun2.11 / Fun2.12
Check for obstruction. Reset the position of the tube infeed
307 F2.11/F2.12 - Overload tube infeed presser 18 presser. Fun2.11 / Fun2.12
308 F2.11/F2.12 - Low level tube infeed chute, ch. {0} 21 Reload the magazine with tubes. Fun2.11 / Fun2.12
309 F2.12 - Overload infeed device, ch. {0} 18 Check for obstruction. Fun2.12
310 F2.11/F2.12 - Low level tube infeed magazine, ch. {0} 20 Reload the magazine with tubes. Fun2.11 / Fun2.12
311 F7.02 - Positive reject check failed, PnP stn 2, ch. {0} 18 Check the mechanics or the sensor. Fun7.02

Check the mechanics of the lift spindles and that the correct
312 F7.02 - Positive reject check sensor faulty, PnP stn 2, ch. {0} 18 format parts are mounted. Check the functionality of the sensor. Fun7.02
Safe torque signal is low should be high. (Set input to 0 if inverter
313 F2.11 - Norden store magazine, safe torque off 18 broken) Fun2.11
Safe torque signal is high should be low. (Set input to 0 if inverter
314 F2.11 - Norden store magazine, safe torque on 18 broken) Fun2.11

315 F6.17 - Flattening jaws, high temperature, ch. {0} 18 Acknowledge the alarm, wait for correct temperature. Restart Fun6.17
316 F6.17 - Flattening jaws, low temperature, ch. {0} 18 Wait for the temp. to arrive to correct level. Restart. Fun6.17
317 F6.17 - Flattening jaws, temperature sensor error, ch. {0} 18 Check the sensor and its connection. Fun6.17

Check the mechanics of the lift spindles and that the correct
318 F7.10 - Rejection after filling faulty, ch. {0} 17 format parts are mounted. Check the functionality of the sensor. Fun7.10

Check the mechanics of the lift spindles and that the correct
319 F7.10 - Positive reject check after filling failed, ch. {0} 17 format parts are mounted. Check the functionality of the sensor. Fun7.10
Check the mechanical position of the lift spindles and the outfeed
320 F7.11 - Lift first product discharge failed, ch. {0} 17 chutes. Check the function of the sensors. Fun7.11
321 F7.11 - Positive reject check failed, first product discharge, ch. {0} 18 Check the mechanics or the sensor. Fun7.11
Alarm list used by NML150 - 10011
No. Description Type What to do Function

Check the mechanics of the lift spindles and that the correct
322 F7.11 - Positive reject check sensor faulty, first product discharge, ch. {0} 18 format parts are mounted. Check the functionality of the sensor. Fun7.11
Check the mechanics for obstruction and the functionality of the
323 F7.12 - Positive reject check failed, second product discharge, ch. {0} 18 sensor. Fun7.12

Check the mechanics of the lift spindles and that the correct
324 F7.12 - Positive reject check sensor faulty, second product discharge, ch. {0} 18 format parts are mounted. Check the functionality of the sensor. Fun7.12
325 F5.13 - Heated pump, high temperature, ch. {0} 18 Wait for correct temperature Fun5.13
326 F5.13 - Heated pump, low temperature, ch. {0} 18 Wait for correct temperature Fun5.13
327 F5.13 - Heated pump, temperature sensor error, ch. {0} 18 Check connections and sensor Fun5.13
328 F5.14 - Heated nozzle, high temperature, ch. {0} 18 Wait for correct temperature Fun5.14
329 F5.14 - Heated nozzle, low temperature, ch. {0} 18 Wait for correct temperature Fun5.14
330 F5.14 - Heated nozzle, temperature sensor error, ch. {0} 18 Check connections and sensor Fun5.14
331 F7.13 - Tube turning not executed, ch. {0} 18 Fun7.13
332 F7.13 - Tube turning unit not ready, ch. {0} 18 Check the power supply to the drive stage. Fun7.13
333 F2.11 - Norden store magazine door open 21 Close NSM doors or check door relay Fun2.11
334 F7.16 - Bad tube at manual reject station 18 Remove tube from reject station Fun7.16
335 F4.11 - Fill pump 1, overload, ch. {0} 17 Check the mechanics of the pump piston. Fun4.11
336 F4.11 - Fill pump 2, overload, ch. {0} 17 Check the mechanics of the pump piston. Fun4.11
337 F4.11 - Fill pump 3, overload, ch. {0} 17 Check the mechanics of the pump piston. Fun4.11
338 F2.11 - Norden store magazine elevator overload, infeed 18 Check for obstruction. Fun2.11
339 F2.11 - Norden store magazine elevator overload, outfeed 18 Check for obstruction. Fun2.11

340 F3.17 - Camera 1: Valid signal missing for Dented tube check, ch. {0} 18 Check vision system, external trigger + inspect button activated. Fun3.17
341 F3.17 - Camera 1: Dented tube check error, ch. {0} 18 Check the condition of the tube. Adjust the the camera Fun3.17
342 F3.17 - Camera 1: Dented tube check stuck value signal, ch. {0} 18 Check value signal, reload backup Fun3.17

343 F3.17 - Camera 2: Valid signal missing for Dented tube check (outer), ch. {0} 18 Check vision system, external trigger + inspect button activated. Fun3.17
344 F3.17 - Camera 2: Dented tube check (outer) error, ch. {0} 18 Check the condition of the tube. Adjust the the camera Fun3.17
Alarm list used by NML150 - 10011
No. Description Type What to do Function

345 F3.17 - Camera 2: Dented tube check (outer) stuck value signal, ch. {0} 18 Check value signal, reload backup Fun3.17

346 F3.17 - Camera 3: Valid signal missing for Foreign matters check, ch. {0} 18 Check vision system, external trigger + inspect button activated. Fun3.17
347 F3.17 - Camera 3: Foreign matters check error, ch. {0} 18 Check the condition of the tube. Adjust the the camera Fun3.17
348 F3.17 - Camera 3: Foreign matters check stuck value signal, ch. {0} 18 Check value signal, reload backup Fun3.17

349 F3.17 - Camera 4: Valid signal missing for Foreign matters check (outer) ch. {0} 18 Check vision system, external trigger + inspect button activated. Fun3.17
350 F3.17 - Camera 4: Foreign matters check (outer) error, ch. {0} 18 Check the condition of the tube. Adjust the the camera Fun3.17
351 F3.17 - Camera 4: Foreign matters check (outer) stuck value signal, ch. {0} 18 Check value signal, reload backup Fun3.17

352 F3.17 - Camera 5: Valid signal missing for Data Matrix check, ch. {0} 18 Check vision system, external trigger + inspect button activated. Fun3.17
353 F3.17 - Camera 5: Data matrix check error, ch. {0} 18 Check the condition of the tube. Adjust the the camera Fun3.17
354 F3.17 - Camera 5: Data matrix check stuck value signal, ch. {0} 18 Check value signal, reload backup Fun3.17

355 F3.17 - Camera 6: Valid signal missing for Data matrix check (outer), ch. {0} 18 Check vision system, external trigger + inspect button activated. Fun3.17
356 F3.17 - Camera 6: Data matrix check (outer) error, ch. {0} 18 Check the condition of the tube. Adjust the the camera Fun3.17
357 F3.17 - Camera 6: Data matrix check (outer) stuck value signal, ch. {0} 18 Check value signal, reload backup Fun3.17

358 F3.17 - Camera 7: Valid signal missing for OCV & Data matrix check, ch. {0} 18 Check vision system, external trigger + inspect button activated. Fun3.17
359 F3.17 - Camera 7: OCV & Data matrix check error, ch. {0} 18 Check the condition of the tube. Adjust the the camera Fun3.17
360 F3.17 - Camera 7: OCV & Data matrix check stuck value signal, ch. {0} 18 Check value signal, reload backup Fun3.17

361 F3.17 - Camera 8: Valid signal missing for OCV & Data matrix check (outer), ch. {0} 18 Check vision system, external trigger + inspect button activated. Fun3.17
362 F3.17 - Camera 8: OCV & Data matrix check (outer) error, ch. {0} 18 Check the condition of the tube. Adjust the the camera Fun3.17
363 F3.17 - Camera 8: OCV & Data matrix check (outer) stuck value signal, ch. {0} 18 Check value signal, reload backup Fun3.17

364 F3.17 - Camera 9: Valid signal missing for Sealing check, ch. {0} 18 Check vision system, external trigger + inspect button activated. Fun3.17
365 F3.17 - Camera 9: Sealing check error, ch. {0} 18 Check the condition of the tube. Adjust the the camera Fun3.17
366 F3.17 - Camera 9: Sealing check stuck value signal, ch. {0} 18 Check value signal, reload backup Fun3.17

367 F3.17 - Camera 10: Valid signal missing for Sealing check (outer), ch. {0} 18 Check vision system, external trigger + inspect button activated. Fun3.17
Alarm list used by NML150 - 10011
No. Description Type What to do Function

368 F3.17 - Camera 10: Sealing check (outer) error, ch. {0} 18 Check the condition of the tube. Adjust the the camera Fun3.17
369 F3.17 - Camera 10: Sealing check (outer) stuck value signal, ch. {0} 18 Check value signal, reload backup Fun3.17

370 F3.17 - Camera 11: Valid signal missing for vision system, ch. {0} 18 Check vision system, external trigger + inspect button activated. Fun3.17
371 F3.17 - Camera 11: Vision system tube check error, ch. {0} 18 Check the condition of the tube. Adjust the the camera Fun3.17
372 F3.17 - Camera 11: Vision system stuck value signal, ch. {0} 18 Check value signal, reload backup Fun3.17

373 F3.17 - Camera 12: Valid signal missing for vision system, ch. {0} 18 Check vision system, external trigger + inspect button activated. Fun3.17
374 F3.17 - Camera 12: Vision system tube check error, ch. {0} 18 Check the condition of the tube. Adjust the the camera Fun3.17
375 F3.17 - Camera 12: Vision system stuck value signal, ch. {0} 18 Check value signal, reload backup Fun3.17
376 F3.17 - Camera: Vision system not running, camera no. {0} 18 Start the vision system Fun3.17
377 F3.17 - Camera: Vision system format error, camera no. {0} 18 Check format, reload backup Fun3.17
378 F3.17 - Camera: Code mis-match 18 Check code Fun3.17
379 F3.19 - Code reader unit not ready 18 Reader system not in run mode. Fun3.19
380 F3.19 - Tube type read error, ch. {0} 18 Check reader adjustments. Fun3.19
381 F3.19 - Tube type match error, ch. {0} 18 Wrong tube loaded. Fun3.19
382 F3.19 - Tube marking read error, ch. {0} 18 Check reader adjustments. Fun3.19
383 F3.19 - Tube marking error, ch. {0} 18 Wrong printing/laser marking on the tube. Fun3.19
384 F3.19 - Tube box read error, no. {0} 18 Check reader adjustments. Fun3.19
385 F3.19 - Tube box match error, no. {0} 18 Wrong tube box loaded. Fun3.19
386 F2.11 - Norden store magazine elevator overload, clutch 18 Check for obstruction. Fun2.11
Check the 3:rd lift station if there is a tube holder missing or if
387 F3.14 - Tube holder not in place at 3:rd lift, ch. {0} 17 there is an error with the sensor. Fun3.14
388
389
390
391
392
393
Alarm list used by NML150 - 10011
No. Description Type What to do Function

394
395
396
397
398
399
400

Type of alarm:

1 = AsyncStop (NOTE! Will generate GE_ALARM_TYPE_ASYNCSTOPNORDEN in NC)

2 = SyncStopEL (NOTE! Will generate GE_ALARM_TYPE_ASYNCSTOPNORDEN in NC)

3 = SyncStopEH (NOTE! Will generate GE_ALARM_TYPE_ASYNCSTOPNORDEN in NC)


4 = StopEndOfCycle
5 = MainsContactorOff
17 = GE_ALARM_TYPE_STOPPOS0
18 = GE_ALARM_TYPE_STOPPOS1
20 = GE_ALARM_TYPE_LOWLEVELWARNING
21 = GE_ALARM_TYPE_WARNING
22 = GE_ALARM_TYPE_INFORMATION
23 = GE_ALARM_TYPE_STOPPOS1AUTORESTART
24 = GE_ALARM_TYPE_LOWLEVELSTOP
25 = GE_ALARM_TYPE_UPSTREAMSTOP
26 = GE_ALARM_TYPE_UPSTREAMSTOPAUTORESTART
27 = GE_ALARM_TYPE_DOWNSTREAMSTOP
28 = GE_ALARM_TYPE_DOWNSTREAMSTOPAUTORESTART
Alarm list used by NML150 - 10011
No. Description Type What to do Function
29 = GE_ALARM_TYPE_ASYNCSTOPNORDEN (NOTE! Only for NC)

30 = GE_ALARM_TYPE_SYNCSTOPELNORDEN (NOTE! Only for NC and should only be


used for Alarm 371) (Will generate Alarm type 2 - SyncStopEL when master vel = 0)