You are on page 1of 1

INSPECTION OF CRADLE / RSP

Name of Customer : Test Date :


Address :

Capacity:………..…...……Kg, Make :……...……………..………...…, Model No………..……….………….


Sr. No. / ID. NO. : …………………, Yr of Mfg …………….……., Counter weights: ………………………….
Present - Wire Rope Dia :……………..……..mm, Falls… ……..…., Height/floors :…………..………Mtrs
Platform Size - Length ……..…….Mtrs, Location : ……………………………………………………………..
PRECHECKS - Roof TOP INSIDE CAGE
1 Check wire rope terminations / U Clamps 1 Check power cable terminations
2 Check wire rope condition 2 Check console/remote button operations
3 Total Conter weight 3 Check updown operations from Panel
4 Locking of counter weight - Nutbolt/Wire 4 Check bulbs in cradle control panel
5 Condition of Beam (Front & Back) 5 Check Bucket Condition
6 Condition of Reinforcing Wire / Clamping 6 Check Bucket Locking Pins
7 Condition of Tommy Bar 7 Check Bucket Flooring for slipage
8 Check beam, is not resting on wall 8 Check Toe Board
9 Check Life line ancorage 9 Check Fire extinguisher in bucket
PRECHECKS - Ground Level 10 Check resting Platform
1 Area Baricaded - Hard Barication 11 Check Life Line
2 Access to platform 12 Check the SWL and serial number plate
3 Safety from falling debris 13 Check hammer weight for secondary rope
4 Body / Electrical Earthing 14 Motor Cover
5 Check Castors / Bottom Frame in place 15 Check Paints condition and corrosion
6 Power Cable condition 16 Inspect all mounting bolts
Cradle Safety 17 Inspect load cell installed
1 Check cradle hoist and lowering functions 18 Check approprite height ( 1 Mtrs)
2 Check free rotation of pully 19 Front and Back Railing Height
3 Check free rotation of captive rope rollers 20 Panel condition and lock
4 Check braking / Slippage 21 Wall side Roller
5 Check cradle Upper limits Switch Cradle Load test
6 Check cradle Upper limit plate 1 Over Load protection Device if any
7 Check emergency stop 2 Over Load protection working/Calibrated
8 Check MCB operation 3 Over pulling device for power cable
9 Test cradle out of level / Anti tilt system 4 Weight test the cradle and proof load
10 Inspect traverse rope 5 Test Load ( Kg)
11 Check manual release mechanism 6 Over load protection cable
12 Wire rope should be non rotating Docs
13 Manual relase lever present 1 Operator Credentails / Skills / Knowledge
14 Fire Extinguisher has not expired 2 TPI / ID Displayed
Remarks / Observations :
1 .
2 .
3 .
4 .
5 .
6 .
7 .
8 .
9 .
10 .

For BTS Client / Witnessed by