You are on page 1of 7

Internal Ctrl. No.

: 461116-100127-43636-0005
Doc No:
GFDP-107-52-ELE-DS-GE-005
PETRONAS
Date:
07-Jul-2014

TypicalDatasheet
Data Sheet for Well Pad Distribution Rev: Page
for Distribution Transformer for Transformers
GIFT Offsite Facilities Substation
3 1 of 7

DATASHEETTYPICAL DATA SHEETTRANSFORMER


FOR DISTRIBUTION FOR WELL PADFOR
DISTRIBUTION TRANSFORMERS
GIFT OFFSITE FACILITIES SUBSTATION

FOR

GARRAF FINAL DEVELOPMENT PLAN (GFDP)

Revision No. Revision Description Date of Issue


3 Issued for Bid 07-Jul-2014

Prepared By Reviewed By Approved By


Revision No.
Initials Date Init
nittials
Initials Date In
Initials Date
3 TMT 07-Jul-2014 BT
B T/RSA
T/
BT/RSA 07-Jul-2014 AE 07-Jul-2014

PROJECT DOCUMENTS ARE CONTROLLED DOCUMENTS.

Class 1
Internal Ctrl. No.: 461116-100127-43636-0005

GARRAF FINAL DEVELOPMENT PLAN (GFDP)

Document No.: GFDP-107-52-ELE-DS-GE-005


Revision : 3
Page : 2 of 7

Typical Data Sheet


Datasheet for Well Transformer
for Distribution Pad Distribution Transformers
for GIFT Offsite Facilities Substation

REVISION HISTORY

Rev. Date Description of Change


A 09-Jun-13 Issued for Review. No Comments
Issued for Bid. Rating change due to addition of custom bonded area
0 15-Jul-13
load
Issued for Bid. Rating change due to deletion of custom bonded area
1 18-Dec-13
load
2 27-Apr-14 Issued for Bid. PIR comments incorporated
Internal Ctrl. No.: 461116-100127-43636-0005

GARRAF FINAL DEVELOPMENT PLAN (GFDP)

Document No.: GFDP-107-52-ELE-DS-GE-005


Revision : 3
Page : 3 of 7

Typical Data
Datasheet forSheet for Well
Distribution Pad Distribution
Transformer for GIFT Transformers
Offsite Facilities Substation

1 SERVICE: ITEM No.: N/A QTY: 2


2 P.O NUMBER SIZE:
3 INFORMATION BY BUYER
4 A APPLICABLE REFERENCE DOCS
5 1 SPECIFICATION GFDP-COM-52-ELE-SP-GE-005
6 2 MANUFACTURING STANDARD IEC 60076
7 3 TRANSFORMER TAG NO. TR-OFS-B-03, TR-OFS-B-04
8

9 B SERVICE / SITE CONDITION


10 1 SERVICE/APPLICATION DISTRIBUTION TRANSFORMER
11 2 DESIGN AMBIENT TEMP. ( MAXIMUM / MINIMUM ) 55°C/-5°C
12 3 ALTITUDE ABOVE M.S.L. 3m
13 4 MIN - MAX RELATIVE HUMIDITY 0% - 90%
14 5 SEISMIC ZONE IBC 2012 SITE CLASS D
15

16 C AREA CLASSIFICATION
17 1 SAFE / HAZARDOUS SAFE
18 2 INDOOR / OUTDOOR OUTDOOR, UNDER SUN SHADE
19

20 D SYSTEM CHARACTERISTICS
21 1 PRIMARY SYSTEM:
22 1.1 VOLTAGE 33kV ±10%
23 1.2 NO. OF PHASES / WIRE 3 PHASE / 3 WIRE
24 1.3 SYSTEM GROUNDING SOLID GROUNDING
25 1.4 SYMMETRICAL FAULT LEVEL (R.M.S) 25 kA
26 2 SECONDARY SYSTEM:
27 2.1 VOLTAGE (FULL LOAD) 400V
28 2.2 NO. OF PHASES / WIRE 3 PHASE / 4 WIRE
29 2.3 SYSTEM GROUNDING SOLID GROUNDING
30

31 E TECHNICAL PARTICULARS
32 1 RATING 300kVA
300 kVA (To be confirmed during detailed design)
33 2 NO. OF PHASES THREE
34 3 VOLTAGE RATIO : PRIMARY / SECONDARY 6.6/0.42kV
33 / 0.42kV
35 4 VECTOR GROUP Dyn 11
36 5 FREQUENCY 50Hz ±2%
37 6 % IMPEDANCE VOLTAGE 4%
38 7 TYPE OF COOLING ONAN
KNAN
39 8 INSTALLATION OUTDOOR UNDER SUN SHADE
40 9 INSULATION LEVEL
41 10 a) FOR IMPULSE TEST PRY-170kV, SRY-Not applicable AS PER IEC 60076
42 b) FOR POWER FREQUENCY PRY-70kV, SRY-3kV rms AS PER IEC 60076
43 11 TEMPERATURE RISE:
44 a) WINDING 50°C OVER 55°C AMBIENT (HOT SPOT)
45 b) OIL 45°C OVER 55°C AMBIENT
46 12 TYPE OF TRANSFORMER (CONSERVATOR / SEALED) HERMETICALLY SEALED TYPE
47 13 ADDITIONAL BUSHING FOR NEUTRAL EARTHING :
48 a) FOR PRIMARY NOT REQUIRED
49 b) FOR SECONDARY REQUIRED
50 c) EARTH CONDUCTOR SIZE (SEE NOTE-6)
51 14 TAP CHANGER : HV SIDE OFF CIRCUIT
52 RANGE OF TAPS / STEPS ±5% IN STEPS OF 2.5% (+5%, +2.5%, 0, -2.5%, -5%)
53 ON LOAD TAP CHANGER : AUTO & MANUAL NOT APPLICABLE
54 15 PROTECTIVE CT's
55 HV SIDE : (PRIMARY) NOT APPLICABLE
56 LV SIDE : (SECONDARY) NOT APPLICABLE
57
Internal Ctrl. No.: 461116-100127-43636-0005

GARRAF FINAL DEVELOPMENT PLAN (GFDP)

Document No.: GFDP-107-52-ELE-DS-GE-005


Revision : 3
Page : 4 OF 7

Typical Data
Datasheet Sheet forTransformer
for Distribution Well Pad Distribution Transformers
for GIFT Offsite Facilities Substation

1 SERVICE: ITEM No.: N/A QTY: 2


2 P.O NUMBER SIZE:

3 INFORMATION BY BUYER
4 LV SIDE : (NEUTRAL) APPLICABLE
5 CT-3 RATIO 500/1A
6 ACCURACY CLASS, BURDEN 5P20, 10VA
7 16 MOUNTING OF CT's (LOCATION) :

8 HV SIDE NOT APPLICABLE


9 LV SIDE NEUTRAL TERMINAL BOX

10 17 VOLTAGE OF ALARM AND TRIP CONTACTS 230V AC

11 18 VOLTAGE OF MARSHALLING BOX SPACE HEATER (IF REQUIRED) 230V AC

12

13 F CONSTRUCTION

14 1 TERMINAL BOX ARRANGEMENT : HV & LV ON SIDE WALLS OF TRANSFORMER, IP55

15 2 PRIMARY TERMINAL TYPE CABLE BOX WITH DISCONNECTING CHAMBER,IP 55 MINIMUM

16 3 CABLE / CONDUCTOR SIZE (SEE NOTE-6)

17 4 SECONDARY TERMINAL TYPE CABLE BOX WITH DISCONNECTING CHAMBER,IP 55 MINIMUM

18 5 CABLE / CONDUCTOR SIZE (SEE NOTE-6)

19 6 RADIATOR (*)

20 7 PAINTING TYPE AND SHADE RAL 7035

21 8 FITTINGS & ACCESSORIES (MINIMUM) PROTECTION RELAY (DGPT2) WITH ALARM & TRIP CONTACTS

22 PRESSURE RELIEF VALVE WITH TRIP CONTACT

23 OIL LEVEL INDICATOR WITH ALARM CONTACT

24 BREATHER

25 DRAIN/SAMPLING VALVE

26 FILTER VALVE

27 THERMOMETER POCKET WITH CAP

28 TAP CHANGER WITH POSITION INDICATOR & PADLOCK FACILITIES

29 MARSHALLING BOX, IP55

30 JACKING PADS, LIFTING/PULLING LUGS,

31 EARTH BOSS, RATING PLATE

32 9 TYPE OF OIL NON TOXIC, SYNTHETIC MINERAL OIL

33 10 BI-DIRECTIONAL RAILWHEEL / ROLLER BI-DIRECTIONAL ROLLERS WITH SKID UNDERBASE

34

35 G INSPECTION & TESTING

36 1 ROUTINE TESTS REQUIRED, AS PER GFDP-COM-52-ELE-SP-GE-005

37 2 TYPE TESTS AS PER GFDP-COM-52-ELE-SP-GE-005

38 3 SPECIAL TESTS AS PER GFDP-COM-52-ELE-SP-GE-005

39 4 FAT REQUIRED, AS PER GFDP-COM-52-ELE-SP-GE-005

40

41

42 H NOTES & ADDITIONAL REQUIREMENTS

43 1 SEE PAGE 7 OF THIS DOCUMENT.

44

45

46

47

48

49

50

51

52

53

54

55
56
Internal Ctrl. No.: 461116-100127-43636-0005

GARRAF FINAL DEVELOPMENT PLAN (GFDP)

Document No.: GFDP-107-52-ELE-DS-GE-005


Revision : 3
Page : 5 OF 7

Typicalfor
Datasheet Data Sheet for
Distribution Well Pad Distribution
Transformer Transformers
for GIFT Offsite Facilities Substation

1 SERVICE: ITEM No.: N/A QTY: 2

2 P.O NUMBER SIZE:


3 INFORMATION BY VENDOR
4
5 A GENERAL
6 1 MANUFACTURER NAME (*)
7 2 COUNTRY OF ORIGIN (*)
8 3 GOVERNING MANUFACTURING STANDARD (*)
9 4 TRANSFORMER SERIES NAME (*)
10 5 TYPE TESTED TRANSFORMER ( YES / NO) (*)
11 6 LIST OF TYPE TEST WITH DATE OF VALIDITY (*)
12 7 NAME OF TESTING AUTHORITY (*)
13 (*)
14 B CONSTRUCTION
15 1 RATED kVA AS PER IEC - 60076 (*) kVA
16 2 CONTINUOUS MAXIMUM RATING FOR SITE CONDITIONS (*) kVA
17 3 NO LOAD VOLTAGE RATIO (*)
18 4 VECTOR GROUP REFERENCE (*)
19 5 NO LOAD LOSSES AT RATED VOLTAGE (*) kW
20 6 LOAD LOSSES AT RATED CURRENT, 75ºC (*) kW
21 7 RESISTANCE VOLTAGE (AT RATED kVA, 75ºC & 50 Hz) (*) %
22 8 REACTANCE VOLTAGE (AT RATED kVA, 75ºC & 50 Hz) (*) %
23 9 IMPEDANCE VOLTAGE (AT RATED kVA, 75ºC & 50 Hz) (*) +-%
24 10 RESISTANCE OF WINDING, AT 75ºC (*)
25 Ohms
26 Ohms
27 11 ZERO PHASE SEQUENCE IMPEDANCE ( ESTIMATED ) (*) %
28 12 EFFICIENCY ( AT 75ºC ) AT FULL LOAD (*) %
29

30

31 13 SEALED TYPE OF TRANSFORMER (YES / NO) (*)


32 14 PERCENTAGE REGULATION AT FULL LOAD (*)
33 %
34 %
35 15 EXCITING CURRENT REFERRED TO PRIMARY, 50 Hz (*)
36 A
37 A
38 A
39 16 POWER FACTOR OF EXCITING CURRENT AT RATED VOLTAGE AND 50 Hz (*) %
40 17 MAGNETISING INRUSH CURRENT ( PEAK ) UNDER WORSE CONDITIONS OF RESIDUAL (*) A
41 MAGNETISM & INSTANT OF SWITCHING
42 18 SYMMETRICAL SHORT-CIRCUIT CURRENT (ASSUME INFINITE SOURCE) (*) kA
43 19 TIME OF WITHSTAND WITHOUT INJURY UNDER MAX. SYMM. SHORT CIRCUIT CONDITION (*) Sec
44 20 THERMAL TIME CONSTANT (*) Hrs
45 21 X/R RATIO (*)
46 22 MAXIMUM FLUX DENSITY IN CORE AT RATED VOLTAGE (*)
47 23 CURRENT DENSITY AT RATED LOAD (*)
48 a) HV WINDING A / mm2
49 b) LV WINDING A / mm2
50 24 TYPE OF WINDING (*)
51 a) HIGH VOLTAGE
52 b) LOW VOLTAGE
53 25 IMPULSE LEVELS WITH 1.2/50 MICRO-SECOND WAVE FORM (*)
54 a) HIGH VOLTAGE kV
55 b) LOW VOLTAGE kV
56
Internal Ctrl. No.: 461116-100127-43636-0005

GARRAF FINAL DEVELOPMENT PLAN (GFDP)

Document No.: GFDP-107-52-ELE-DS-GE-005


Revision : 3
Page : 6 OF 7

Datasheet forData
Typical Distribution Transformer
Sheet for Well Padfor GIFT OffsiteTransformers
Distribution Facilities Substation

1 SERVICE: ITEM No.: N/A QTY: 2

2 P.O NUMBER SIZE:


3 INFORMATION BY VENDOR
4
5 26 ONE MINUTE POWER FREQUENCY WITHSTAND VOLTAGE (*)
6 a) PRIMARY kV
7 b) SECONDARY kV
8 27 TYPE OF COOLING (*)
9 28 TOTAL WEIGHT WITH OIL & ACCESSORIES (*) kg
10 29 VOLUME OF OIL FOR COMPLETE FILLING (*) Litres
11 30 APPROXIMATE OVERALL DIMENSIONS ( L x W x H ) (*) mm
12 31 DETAILS OF FITTINGS & ACCESSORIES : (*)
13 (VENDOR TO LIST)
14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43
44
45

46

47

48

49

50

51

52

53

54

55

56
57
Internal Ctrl. No.: 461116-100127-43636-0005
GARRAF FINAL DEVELOPMENT PLAN (GFDP)

Document No.: GFDP-107-52-ELE-DS-GE-005


Revision : 3
Page : 7 OF 7
Typicalfor
Datasheet Data Sheet for
Distribution Well Pad Distribution
Transformer Transformers
for GIFT Offsite Facilities Substation

1 SERVICE: ITEM No.: N/A QTY: 2


2 P.O NUMBER SIZE:
3

4 NOTES:

6 1. (*) TO BE PROVIDED AND GUARANTEED BY VENDOR. VENDOR TO PROVIDE ALL OTHER REQUIREMENTS AS PER SPECIFICATION.
7 2. PERFORMANCE DATA SHALL BE FURNISHED FOR MAXIMUM RATING.
8 3. LOSSES SHALL BE INCLUSIVE OF POSITIVE TOLERANCE AND SHALL BE IN NOMINAL TAP.
9 4. LANGUAGE OF DOCUMENTS AND LANGUAGE ON EQUIPMENTS SHALL BE ENGLISH
10 5. DRAWING, DATAS AND TEST CERTIFICATES SHALL BE AS PER GFDP-COM-52-ELE-SP-GE-005
11 6. CABLE, GLAND SIZES FOR TERMINAL BOXES ARE ON HOLD AND SHALL BE UPDATED BY EPC CONTRACTOR DURING DETAILED ENGINEERING.
12 7. RATINGS SHALL BE UPDATED BY THE EPC CONTRACTOR BASED ON FINAL VENDOR DATA DURING DETAILED ENGINEERING.
13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37
38
39

40

41

42

43

44

45

46

47

48
49
50
51

52
53

54
55