O S T E O P O R O S I S A S S E S S M E N T

Explorer Product Specifications BMD for spine and hip, Scan/Analyze Protocols for AP lumbar spine,
The power of Hologic is the power of clear innovation and a singular
proximal femur, Dual Hip™, scoliotic spine, pediatric spine and hip

Scanning method: Optional Software: focus . . . to challenge the boundaries of science and technology everyday
X-ray fan beam, utilizing motorized table and C-arm IRIS complete package** (includes DICOM, Physician’s Viewer,
DICOM Worlist, HL7 Output, Physician’s Report Writer) General to raise the standards of image quality. Our passion has led to
X-ray System: Region of Interest, Forearm, Prosthetic Hip, Whole Body, Pediatric
Switched-pulse dual-energy (100kVp/140kVp) Whole Body, Body Composition with Sub Regional Analysis, Pediatric discoveries that contribute to earlier detection, more accurate diagnoses,
Reference Data†, DAP, QDR Mobility™, DXA Practice Manager™
Detector System: † For investigational use in the USA
* Installation requirements for X-ray equipment vary. Check with local regulatory and better overall patient care. As we focus on the future, we are bound
Multi-element solid-state detector array authorities.
** Some components of the IRIS package can be purchased separately. by our clarity of vision. A vision created solely to enhance yours.
Scatter Dose:
1.0 mR/hr (0.01 mSv/hr) nominal measured at 1m from the Site Plan
examination table Room Size: 2.45m x 2.45m (8 ft x 8 ft)
2.45m x 3.06m (8 ft x 10 ft) Whole Body Option
External Shielding: Door Opening: 72cm (28in) minimum
None required* Osteoporosis Assessment  DirectRay® Digital Imaging
Floor Loading: 2155N/m2 (45lbs./sq ft) minimum
Electric Power: 100 / 120 / 230VAC, 50 / 60Hz @ 16 / 14 / 7A max
LORAD® Breast Cancer Detection  FLUOROSCAN™ C-arm Imaging
BMD Precision: dedicated circuit
<1.0% Connection (plug) as required installation location

Calibration: Explorer Specification


Self-calibrating using patented Hologic Automatic Internal Reference Explorer Explorer with Whole Body (option)
System, Automated Quality Control program, Operator calibration not Scan 96cm x 51cm 195cm x 65cm
required Region (38in x 20in) (77in x 26in)

Operating Requirements: Footprint 2.02m x 1.05m 2.02m x 1.05m


Temperature: 15° - 32°C (60° - 90° F ) (79.5in x 41in) (79.5in x 41in)
Power: 100VAC (16A)/120VAC (14A)/230VAC 8(A) Table Extended
Humidity: 20%-80% relative humidity, non condensing 3.02m x 1.50m
Average Heat Load: 3,400 BTU/hr (119in x 59in)
System Table/C-arm Table/C-arm
Patient/Table Weight Limit:
Weight 295kg (650lb) 295kg (650lb)
137kg (300 lbs.)
Control Console Control Console
Table Height: 6.8kg (15lb) 6.8kg (15lb)
71cm (28 in.)
Explorer Scan Site Specifications
Standard Hardware Configuration: Standard: Optional:
Computer worktable with Intel Celeron PC, 40GB (min)hard drive, Lumbar Spine Forearm
256MB (min) RAM, 64MB (min) video board, On System Board Proximal Femur Decubitus Lateral BMD
Network Card, 17 inch monitor, inkjet color printer, CD R/W drive

Optional Hardware:
Magneto Optical Disk Storage, HP LaserJet® B & W printer, Modem,
Network, 15" flat panel monitor, Oasis QDR for Windows XP stand-
Dual Hip Prosthetic Hip
Whole Body

Explorer Typical Performance (60Hz)*


Corporate Headquarters
35 Crosby Drive
Europe
Horizon Park
Asia Pacific
Room 302, Hung Kei Building
Explorer ™

alone workstation
Exam Scan Time Exposure Bedford, MA 01730-1401 USA
Tel: 781.999.7300
Leuvensesteenweg
510, BUS 31
5-8 Queen Victoria Street Fan-beam DXA for the Cost-Conscious Practice
Lumbar Spine 90s 0.07mGy Central, Hong Kong
Proximal Femur 90s 0.07mGy Fax: 781.280.0668 1930 Zaventem, Belgium Tel: 852.3102.9200
Standard Software Configuration: www.hologic.com Tel: 32.2.711.4680 Fax: 1.425.696.7846
Whole Body 6.7min 0.011mGy
QDR for Windows® XP Operating System, Tech Tips™, Express Exam, Fax: 32.2.725.2087
*50Hz and other scan modes available
NHANES Reference Data, QDR OnePage Report, Context Sensitive
B-145 US/International (1/04) © Hologic 2004. All rights reserved. Printed in USA. Specifications are subject to change without prior notice. Hologic and Hologic logos, QDR, Discovery, OnePass, Express BMD, Express
Help, Fracture Risk Indication, OneTime™ Auto Analysis, Auto Low Exam, QDR Mobility, IRIS, OnePage Dx Report, Tech Tips, DXA Practice Manager, OneTime Auto Analysis, Dual Hip, A Hologic Company, are trademarks or registered trademarks of Hologic, Inc., in the United States an
other countries. Windows is a registered trademark of Microsoft Corporation. HOLOGIC OSTEOPOROSIS ASSESSMENT
HOLOGIC OSTEOPOROSIS ASSESSMENT
A Milestone in the assessment of osteoporosis Physician’s Report Writer*
Produces a comprehensive electronic report in Microsoft® Word
Value-added Features and Options
Health Level format for electronic distribution and printing.
Seven (HL7)
Report
QDR One-Page Report
Explorer (ik-splor’er) n.— OnePage Dx™ Report* Combine image, scan analysis, and reference curves in a concise, easy-to-read, visually impressive, single-page
A comprehensive, one-page report report. The Explorer patient report also contains pertinent patient information and space for diagnosis and
One who carefully searches or examines for the

The QDR Explorer —Hologic’s newest bone densitometer—utilizes our exclusive
purpose of discovery. comments. Choose from several preformatted templates.
OnePass™ fan-beam technology to perform precise bone mineral density The OnePage Dx Report presents BMD results in a
concise, easy-to-read and interpret format. Standard Patient Report Trend Report
(BMD)measurements. Powered by a multi-element solid-state detector array,
The extensive online database of QDR for Windows facilitates serial
Explorer comes equipped with many features found on our high-end DXA systems, reference values included with follow-up of patients. Trend Reports
Explorer simplifies interpretation of provide an easy method to compare
but at a price comparable to older pencil-beam technology.
studies. It includes ethnic-matched visit-to-visit rates of change.
reference data and utilities that Significant changes in bone mineral
The evaluation of bone health has become an essential component of women’s Physician’s Report Writer allow customization of user status are automatically and clearly
reference values to the local patient noted on the report to facilitate
wellness. Meet this growing demand and expand your practice with Explorer.
population. Hip reference data are clinical management.
Explorer’s unique combination of workflow enhancements, electronic reporting based on NHANES in compliance
Physician’s Interpreting Report*
capabilities and fan-beam technology meet your high standards of patient care and Streamline report writing and workflow
with standardization criteria.

productivity. The Physician’s Interpreting Report automatically Loaded with new features, Express Exam™ Tech Tips™
downloads and formats key information into a Explorer offers a compre- Enables operators to establish routine scan Graphical positioning aid demonstrates
customizable electronic report that includes patient protocols with automated scanning and correct patient alignment, scan start
biographical information, BMD and T/Z-scores. hensive package of analysis workflow. position, and the correct scan, making
Multiple Detector Array The physician can enter final comments via key- advanced clinical tools, it easier than ever for technologists to
board, Canned Text Dictionary, or third-party position patients correctly the first time
X-Ray
speech recognition. time-saving conveniences
Fan C-Arm and every time.
Physician’s Viewer
Beam and practice-building aids.
Linear
Scan
Path TM
OnePass Technology
OnePass technology’s single sweep scanning enables superior image Health Level 7 (HL7) Report (with IRIS Package only)*
quality and unparalleled precision. Developed from a proven The HL7 Report extracts bone density exam results and interpretation as text data
X-Ray Source
technology platform, Explorer’s high performance is made possible from the Physician's Report and formats it for the HIS/RIS system.
Y Drive through several proprietary technologies.
DXA Practice Manager™
True Fan-beam Geometry Modality Worklist* A complete suite of tools to more effectively man-
Explorer’s exclusive design, similar to that found on CT scanners, The Hologic QDR® for Windows® XP operating system connects to HIS/RIS and HL7, age your practice.
utilizes a multi-element detector array paired with true fan-beam simplifying the exchange of text data between QDR workstations and hospital • Patient Call-back List
OnePass acquisition technique delivers acquisition geometry. The true fan-beam design enables rapid, information systems. The Modality Worklist facilitates workflow and reduces input
precise BMD results in a single sweep. • Unlimited 800# for Customer Support
dual-energy bone density measurements. errors. It allows QDR operators to draw text data—admissions information, the daily
order of exams, etc.—from HIS/RIS and view it on the QDR workstation monitor. • Practice Development Guide
Internal Reference System • Osteoporosis Learning Series (up to 16 CME Practice Development Guide
Hologic’s patented Internal Reference System provides automatic credit hours) Take full advantage of Explorer’s practice-building
pixel-by-pixel calibration assuring precise BMD results, test after • Two Days ECE Approved Applications Training potential. Contains two CDs with ready-to-print
test, year after year. by Licensed RT marketing and patient education materials and
• Reference Database Editor marketing tips to help you navigate the myriad
Hologic Anthropomorphic QC Phantom *Optional • Database Export Tools of marketing and media options.
Hologic’s Anthropomorphic Spine QC Phantom confirms • Online Data Conversion
system stability with a life-like standard.

See specifications for availability of options.


HOLOGIC OSTEOPOROSIS ASSESSMENT

See specifications for availability of options.


IRIS
TM

Like all Hologic fan-beam


systems, Explorer provides BMD

Connectivity Solutions measurement with unsurpassed


precision and low patient dose.
Your gateway to true, paperless densitometry Plus, an expanded package of
value added software options,
Hologic leads the industry in providing and complete data compatibility
connectivity solutions for bone densitometry DICOM Modality Worklist with previous generation QDR Explore the possibilities…
systems, streamlining the workflow between instruments.
and within facilities and workstations. Now
physicians and other healthcare providers
can transmit, receive, and review patient
results virtually from anywhere in the world.
With Hologic software, physicians can
interpret bone density data from a remote
workstation. From entering patient data to
physician interpretation, Hologic provides a
comprehensive suite of tools to meet your
connectivity needs.

QDR DICOM

Introducing… Explorer sets a new standard in value and cost-efficiency with features that include:
QDR Mobility
Precise Bone Density Additional Explorer Features detect bone edges in low-density patients,
The Industry’s Only Wireless Mobile Reporting Solution minimizing operator intervention.
Spine and hip BMD results with better than • Image Repositioning allows perfect
Introducing QDR Mobility, an exclusive package of mobile reporting
1% precision. image centering without moving the • Scoliotic Spine Analysis tailors vertebral
tools, enabling physicians to receive BMD studies and generate
reports using a wireless network. Now physicians have the option to patient. BMD assessment to the unique curvature
Express Exam™
interpret scans anywhere, anytime, offering the flexibility essential in • Dual Hip™ automatically moves the table of a patient with scoliosis.
Enables the operator to establish routine
today’s busy medical practices. scan protocols with automated scanning and and C-arm into position for a “mirror” • Automatic Locate feature internally
• Wireless networking analysis workflow. image and measurement of the opposite records and monitors the location of
hip and allows identification of the lowest patient data saved to a storage media,
• Utilize CADfx - point-and-click fracture assessment
Electronic Reporting BMD site for improved clinical assessment. eliminating the need to log patient data.
• Input patient medical history
The most advanced remote interpretation • OneTime™ Auto Analysis delivers • Pediatric Reference Data* for children.
• Generate reports
and reporting software available, including expertly analyzed hip and AP spine scans The database provides whole body, hip and
• Receive and interpret BMD and IVA studies speech recognition compatibility. The IRIS™ instantly. Automatically identifies the region AP spine reference data for North
Connectivity Suite provides seamless of interest, virtually eliminating operator American, Caucasian boys and girls.
Input Patient Medical History Mobile Softcopy Review integration with existing healthcare intervention. *Optional software. For investigational use in the U.S.
and Reporting information systems.
• Automatic Low Density Spine and Hip
Advanced analysis algorithms automatically

See specifications for availability of options. HOLOGIC OSTEOPOROSIS ASSESSMENT


Applications Clinical Applications
Pediatric Applications

Scanning and analysis protocols make


Explorer the system of choice for pediatric
studies. Advanced analysis algorithms
automatically detect and measure very
low-density bone.

Pediatric Spine and Femur Pediatric Whole Body*


Forearm*
Explorer produces simultaneous
assessments of 1/3, mid-, and
ultra-distal regions. Radius and
ulna can be analyzed either
separately or combined. Prosthetic Hip*
Bone resorption around a hip prosthesis
AP Spine and Proximal Femur can eventually contribute to loosening of
Explorer provides unmatched precision for lumbar spine and the implant. Monitoring changes
proximal femur studies. Ninety-second AP spine and proximal in the bone surrounding the prosthesis
femur precision is better than 1.0% (CV at BMD=1.0g/cm2). provides clinicians with pertinent
information regarding bone status and
the viability of the implant.

Decubitus Lateral BMD* The QDR Prosthetic Hip software option


Decubitus lateral spine BMD enables clinicians to obtain automatically identifies and removes the
quantitative measurements of trabecular-rich vertebral bodies. influence of metal to produce precise BMD
Whole Body/BMD Analysis* measurements.
Explorer can evaluate BMD of the entire
skeleton and report on up to 10
adjustable regions of interest.

Subregion Whole Body*


Place up to seven user-defined,
Body Composition Analysis* custom regions for BMD and body
Explorer software enables evaluation of fat composition analysis. Allows
mass, lean mass and total mass for the entire comparison to previous exams
skeleton and for individual sub-regions. Both for patient monitoring.
BMD and body composition can be derived
from a single whole body scan. Hologic fan- Scan Comparison
beam technology is the technology of choice Scan comparison automatically replicates regions of analysis,
for major government-sponsored and minimizing operator involvement and procedure time.
pharmaceutical body composition studies. Hologic’s exclusive
Tissue Calibration Step Phantom, composed of soft tissue and lean
tissue equivalent materials, provides the most reliable tissue
calibration in the industry.

Follow-up Scan Baseline Scan


* Optional

* Optional

See specifications for availability of options. HOLOGIC OSTEOPOROSIS ASSESSMENT


Applications Clinical Applications
Pediatric Applications

Scanning and analysis protocols make


Explorer the system of choice for pediatric
studies. Advanced analysis algorithms
automatically detect and measure very
low-density bone.

Pediatric Spine and Femur Pediatric Whole Body*


Forearm*
Explorer produces simultaneous
assessments of 1/3, mid-, and
ultra-distal regions. Radius and
ulna can be analyzed either
separately or combined. Prosthetic Hip*
Bone resorption around a hip prosthesis
AP Spine and Proximal Femur can eventually contribute to loosening of
Explorer provides unmatched precision for lumbar spine and the implant. Monitoring changes
proximal femur studies. Ninety-second AP spine and proximal in the bone surrounding the prosthesis
femur precision is better than 1.0% (CV at BMD=1.0g/cm2). provides clinicians with pertinent
information regarding bone status and
the viability of the implant.

Decubitus Lateral BMD* The QDR Prosthetic Hip software option


Decubitus lateral spine BMD enables clinicians to obtain automatically identifies and removes the
quantitative measurements of trabecular-rich vertebral bodies. influence of metal to produce precise BMD
Whole Body/BMD Analysis* measurements.
Explorer can evaluate BMD of the entire
skeleton and report on up to 10
adjustable regions of interest.

Subregion Whole Body*


Place up to seven user-defined,
Body Composition Analysis* custom regions for BMD and body
Explorer software enables evaluation of fat composition analysis. Allows
mass, lean mass and total mass for the entire comparison to previous exams
skeleton and for individual sub-regions. Both for patient monitoring.
BMD and body composition can be derived
from a single whole body scan. Hologic fan- Scan Comparison
beam technology is the technology of choice Scan comparison automatically replicates regions of analysis,
for major government-sponsored and minimizing operator involvement and procedure time.
pharmaceutical body composition studies. Hologic’s exclusive
Tissue Calibration Step Phantom, composed of soft tissue and lean
tissue equivalent materials, provides the most reliable tissue
calibration in the industry.

Follow-up Scan Baseline Scan


* Optional

* Optional

See specifications for availability of options. HOLOGIC OSTEOPOROSIS ASSESSMENT


IRIS
TM

Like all Hologic fan-beam


systems, Explorer provides BMD

Connectivity Solutions measurement with unsurpassed


precision and low patient dose.
Your gateway to true, paperless densitometry Plus, an expanded package of
value added software options,
Hologic leads the industry in providing and complete data compatibility
connectivity solutions for bone densitometry DICOM Modality Worklist with previous generation QDR Explore the possibilities…
systems, streamlining the workflow between instruments.
and within facilities and workstations. Now
physicians and other healthcare providers
can transmit, receive, and review patient
results virtually from anywhere in the world.
With Hologic software, physicians can
interpret bone density data from a remote
workstation. From entering patient data to
physician interpretation, Hologic provides a
comprehensive suite of tools to meet your
connectivity needs.

QDR DICOM

Introducing… Explorer sets a new standard in value and cost-efficiency with features that include:
QDR Mobility
Precise Bone Density Additional Explorer Features detect bone edges in low-density patients,
The Industry’s Only Wireless Mobile Reporting Solution minimizing operator intervention.
Spine and hip BMD results with better than • Image Repositioning allows perfect
Introducing QDR Mobility, an exclusive package of mobile reporting
1% precision. image centering without moving the • Scoliotic Spine Analysis tailors vertebral
tools, enabling physicians to receive BMD studies and generate
reports using a wireless network. Now physicians have the option to patient. BMD assessment to the unique curvature
Express Exam™
interpret scans anywhere, anytime, offering the flexibility essential in • Dual Hip™ automatically moves the table of a patient with scoliosis.
Enables the operator to establish routine
today’s busy medical practices. scan protocols with automated scanning and and C-arm into position for a “mirror” • Automatic Locate feature internally
• Wireless networking analysis workflow. image and measurement of the opposite records and monitors the location of
hip and allows identification of the lowest patient data saved to a storage media,
• Utilize CADfx - point-and-click fracture assessment
Electronic Reporting BMD site for improved clinical assessment. eliminating the need to log patient data.
• Input patient medical history
The most advanced remote interpretation • OneTime™ Auto Analysis delivers • Pediatric Reference Data* for children.
• Generate reports
and reporting software available, including expertly analyzed hip and AP spine scans The database provides whole body, hip and
• Receive and interpret BMD and IVA studies speech recognition compatibility. The IRIS™ instantly. Automatically identifies the region AP spine reference data for North
Connectivity Suite provides seamless of interest, virtually eliminating operator American, Caucasian boys and girls.
Input Patient Medical History Mobile Softcopy Review integration with existing healthcare intervention. *Optional software. For investigational use in the U.S.
and Reporting information systems.
• Automatic Low Density Spine and Hip
Advanced analysis algorithms automatically

See specifications for availability of options. HOLOGIC OSTEOPOROSIS ASSESSMENT


A Milestone in the assessment of osteoporosis Physician’s Report Writer*
Produces a comprehensive electronic report in Microsoft® Word
Value-added Features and Options
Health Level format for electronic distribution and printing.
Seven (HL7)
Report
QDR One-Page Report
Explorer (ik-splor’er) n.— OnePage Dx™ Report* Combine image, scan analysis, and reference curves in a concise, easy-to-read, visually impressive, single-page
A comprehensive, one-page report report. The Explorer patient report also contains pertinent patient information and space for diagnosis and
One who carefully searches or examines for the

The QDR Explorer —Hologic’s newest bone densitometer—utilizes our exclusive
purpose of discovery. comments. Choose from several preformatted templates.
OnePass™ fan-beam technology to perform precise bone mineral density The OnePage Dx Report presents BMD results in a
concise, easy-to-read and interpret format. Standard Patient Report Trend Report
(BMD)measurements. Powered by a multi-element solid-state detector array,
The extensive online database of QDR for Windows facilitates serial
Explorer comes equipped with many features found on our high-end DXA systems, reference values included with follow-up of patients. Trend Reports
Explorer simplifies interpretation of provide an easy method to compare
but at a price comparable to older pencil-beam technology.
studies. It includes ethnic-matched visit-to-visit rates of change.
reference data and utilities that Significant changes in bone mineral
The evaluation of bone health has become an essential component of women’s Physician’s Report Writer allow customization of user status are automatically and clearly
reference values to the local patient noted on the report to facilitate
wellness. Meet this growing demand and expand your practice with Explorer.
population. Hip reference data are clinical management.
Explorer’s unique combination of workflow enhancements, electronic reporting based on NHANES in compliance
Physician’s Interpreting Report*
capabilities and fan-beam technology meet your high standards of patient care and Streamline report writing and workflow
with standardization criteria.

productivity. The Physician’s Interpreting Report automatically Loaded with new features, Express Exam™ Tech Tips™
downloads and formats key information into a Explorer offers a compre- Enables operators to establish routine scan Graphical positioning aid demonstrates
customizable electronic report that includes patient protocols with automated scanning and correct patient alignment, scan start
biographical information, BMD and T/Z-scores. hensive package of analysis workflow. position, and the correct scan, making
Multiple Detector Array The physician can enter final comments via key- advanced clinical tools, it easier than ever for technologists to
board, Canned Text Dictionary, or third-party position patients correctly the first time
X-Ray
speech recognition. time-saving conveniences
Fan C-Arm and every time.
Physician’s Viewer
Beam and practice-building aids.
Linear
Scan
Path TM
OnePass Technology
OnePass technology’s single sweep scanning enables superior image Health Level 7 (HL7) Report (with IRIS Package only)*
quality and unparalleled precision. Developed from a proven The HL7 Report extracts bone density exam results and interpretation as text data
X-Ray Source
technology platform, Explorer’s high performance is made possible from the Physician's Report and formats it for the HIS/RIS system.
Y Drive through several proprietary technologies.
DXA Practice Manager™
True Fan-beam Geometry Modality Worklist* A complete suite of tools to more effectively man-
Explorer’s exclusive design, similar to that found on CT scanners, The Hologic QDR® for Windows® XP operating system connects to HIS/RIS and HL7, age your practice.
utilizes a multi-element detector array paired with true fan-beam simplifying the exchange of text data between QDR workstations and hospital • Patient Call-back List
OnePass acquisition technique delivers acquisition geometry. The true fan-beam design enables rapid, information systems. The Modality Worklist facilitates workflow and reduces input
precise BMD results in a single sweep. • Unlimited 800# for Customer Support
dual-energy bone density measurements. errors. It allows QDR operators to draw text data—admissions information, the daily
order of exams, etc.—from HIS/RIS and view it on the QDR workstation monitor. • Practice Development Guide
Internal Reference System • Osteoporosis Learning Series (up to 16 CME Practice Development Guide
Hologic’s patented Internal Reference System provides automatic credit hours) Take full advantage of Explorer’s practice-building
pixel-by-pixel calibration assuring precise BMD results, test after • Two Days ECE Approved Applications Training potential. Contains two CDs with ready-to-print
test, year after year. by Licensed RT marketing and patient education materials and
• Reference Database Editor marketing tips to help you navigate the myriad
Hologic Anthropomorphic QC Phantom *Optional • Database Export Tools of marketing and media options.
Hologic’s Anthropomorphic Spine QC Phantom confirms • Online Data Conversion
system stability with a life-like standard.

See specifications for availability of options.


HOLOGIC OSTEOPOROSIS ASSESSMENT

See specifications for availability of options.


A Milestone in the assessment of osteoporosis Physician’s Report Writer*
Produces a comprehensive electronic report in Microsoft® Word
Value-added Features and Options
Health Level format for electronic distribution and printing.
Seven (HL7)
Report
QDR One-Page Report
Explorer (ik-splor’er) n.— OnePage Dx™ Report* Combine image, scan analysis, and reference curves in a concise, easy-to-read, visually impressive, single-page
A comprehensive, one-page report report. The Explorer patient report also contains pertinent patient information and space for diagnosis and
One who carefully searches or examines for the

The QDR Explorer —Hologic’s newest bone densitometer—utilizes our exclusive
purpose of discovery. comments. Choose from several preformatted templates.
OnePass™ fan-beam technology to perform precise bone mineral density The OnePage Dx Report presents BMD results in a
concise, easy-to-read and interpret format. Standard Patient Report Trend Report
(BMD)measurements. Powered by a multi-element solid-state detector array,
The extensive online database of QDR for Windows facilitates serial
Explorer comes equipped with many features found on our high-end DXA systems, reference values included with follow-up of patients. Trend Reports
Explorer simplifies interpretation of provide an easy method to compare
but at a price comparable to older pencil-beam technology.
studies. It includes ethnic-matched visit-to-visit rates of change.
reference data and utilities that Significant changes in bone mineral
The evaluation of bone health has become an essential component of women’s Physician’s Report Writer allow customization of user status are automatically and clearly
reference values to the local patient noted on the report to facilitate
wellness. Meet this growing demand and expand your practice with Explorer.
population. Hip reference data are clinical management.
Explorer’s unique combination of workflow enhancements, electronic reporting based on NHANES in compliance
Physician’s Interpreting Report*
capabilities and fan-beam technology meet your high standards of patient care and Streamline report writing and workflow
with standardization criteria.

productivity. The Physician’s Interpreting Report automatically Loaded with new features, Express Exam™ Tech Tips™
downloads and formats key information into a Explorer offers a compre- Enables operators to establish routine scan Graphical positioning aid demonstrates
customizable electronic report that includes patient protocols with automated scanning and correct patient alignment, scan start
biographical information, BMD and T/Z-scores. hensive package of analysis workflow. position, and the correct scan, making
Multiple Detector Array The physician can enter final comments via key- advanced clinical tools, it easier than ever for technologists to
board, Canned Text Dictionary, or third-party position patients correctly the first time
X-Ray
speech recognition. time-saving conveniences
Fan C-Arm and every time.
Physician’s Viewer
Beam and practice-building aids.
Linear
Scan
Path TM
OnePass Technology
OnePass technology’s single sweep scanning enables superior image Health Level 7 (HL7) Report (with IRIS Package only)*
quality and unparalleled precision. Developed from a proven The HL7 Report extracts bone density exam results and interpretation as text data
X-Ray Source
technology platform, Explorer’s high performance is made possible from the Physician's Report and formats it for the HIS/RIS system.
Y Drive through several proprietary technologies.
DXA Practice Manager™
True Fan-beam Geometry Modality Worklist* A complete suite of tools to more effectively man-
Explorer’s exclusive design, similar to that found on CT scanners, The Hologic QDR® for Windows® XP operating system connects to HIS/RIS and HL7, age your practice.
utilizes a multi-element detector array paired with true fan-beam simplifying the exchange of text data between QDR workstations and hospital • Patient Call-back List
OnePass acquisition technique delivers acquisition geometry. The true fan-beam design enables rapid, information systems. The Modality Worklist facilitates workflow and reduces input
precise BMD results in a single sweep. • Unlimited 800# for Customer Support
dual-energy bone density measurements. errors. It allows QDR operators to draw text data—admissions information, the daily
order of exams, etc.—from HIS/RIS and view it on the QDR workstation monitor. • Practice Development Guide
Internal Reference System • Osteoporosis Learning Series (up to 16 CME Practice Development Guide
Hologic’s patented Internal Reference System provides automatic credit hours) Take full advantage of Explorer’s practice-building
pixel-by-pixel calibration assuring precise BMD results, test after • Two Days ECE Approved Applications Training potential. Contains two CDs with ready-to-print
test, year after year. by Licensed RT marketing and patient education materials and
• Reference Database Editor marketing tips to help you navigate the myriad
Hologic Anthropomorphic QC Phantom *Optional • Database Export Tools of marketing and media options.
Hologic’s Anthropomorphic Spine QC Phantom confirms • Online Data Conversion
system stability with a life-like standard.

See specifications for availability of options.


HOLOGIC OSTEOPOROSIS ASSESSMENT

See specifications for availability of options.


O S T E O P O R O S I S A S S E S S M E N T

Explorer Product Specifications BMD for spine and hip, Scan/Analyze Protocols for AP lumbar spine,
The power of Hologic is the power of clear innovation and a singular
proximal femur, Dual Hip™, scoliotic spine, pediatric spine and hip

Scanning method: Optional Software: focus . . . to challenge the boundaries of science and technology everyday
X-ray fan beam, utilizing motorized table and C-arm IRIS complete package** (includes DICOM, Physician’s Viewer,
DICOM Worlist, HL7 Output, Physician’s Report Writer) General to raise the standards of image quality. Our passion has led to
X-ray System: Region of Interest, Forearm, Prosthetic Hip, Whole Body, Pediatric
Switched-pulse dual-energy (100kVp/140kVp) Whole Body, Body Composition with Sub Regional Analysis, Pediatric discoveries that contribute to earlier detection, more accurate diagnoses,
Reference Data†, DAP, QDR Mobility™, DXA Practice Manager™
Detector System: † For investigational use in the USA
* Installation requirements for X-ray equipment vary. Check with local regulatory and better overall patient care. As we focus on the future, we are bound
Multi-element solid-state detector array authorities.
** Some components of the IRIS package can be purchased separately. by our clarity of vision. A vision created solely to enhance yours.
Scatter Dose:
1.0 mR/hr (0.01 mSv/hr) nominal measured at 1m from the Site Plan
examination table Room Size: 2.45m x 2.45m (8 ft x 8 ft)
2.45m x 3.06m (8 ft x 10 ft) Whole Body Option
External Shielding: Door Opening: 72cm (28in) minimum
None required* Osteoporosis Assessment  DirectRay® Digital Imaging
Floor Loading: 2155N/m2 (45lbs./sq ft) minimum
Electric Power: 100 / 120 / 230VAC, 50 / 60Hz @ 16 / 14 / 7A max
LORAD® Breast Cancer Detection  FLUOROSCAN™ C-arm Imaging
BMD Precision: dedicated circuit
<1.0% Connection (plug) as required installation location

Calibration: Explorer Specification


Self-calibrating using patented Hologic Automatic Internal Reference Explorer Explorer with Whole Body (option)
System, Automated Quality Control program, Operator calibration not Scan 96cm x 51cm 195cm x 65cm
required Region (38in x 20in) (77in x 26in)

Operating Requirements: Footprint 2.02m x 1.05m 2.02m x 1.05m


Temperature: 15° - 32°C (60° - 90° F ) (79.5in x 41in) (79.5in x 41in)
Power: 100VAC (16A)/120VAC (14A)/230VAC 8(A) Table Extended
Humidity: 20%-80% relative humidity, non condensing 3.02m x 1.50m
Average Heat Load: 3,400 BTU/hr (119in x 59in)
System Table/C-arm Table/C-arm
Patient/Table Weight Limit:
Weight 295kg (650lb) 295kg (650lb)
137kg (300 lbs.)
Control Console Control Console
Table Height: 6.8kg (15lb) 6.8kg (15lb)
71cm (28 in.)
Explorer Scan Site Specifications
Standard Hardware Configuration: Standard: Optional:
Computer worktable with Intel Celeron PC, 40GB (min)hard drive, Lumbar Spine Forearm
256MB (min) RAM, 64MB (min) video board, On System Board Proximal Femur Decubitus Lateral BMD
Network Card, 17 inch monitor, inkjet color printer, CD R/W drive

Optional Hardware:
Magneto Optical Disk Storage, HP LaserJet® B & W printer, Modem,
Network, 15" flat panel monitor, Oasis QDR for Windows XP stand-
Dual Hip Prosthetic Hip
Whole Body

Explorer Typical Performance (60Hz)*


Corporate Headquarters
35 Crosby Drive
Europe
Horizon Park
Asia Pacific
Room 302, Hung Kei Building
Explorer ™

alone workstation
Exam Scan Time Exposure Bedford, MA 01730-1401 USA
Tel: 781.999.7300
Leuvensesteenweg
510, BUS 31
5-8 Queen Victoria Street Fan-beam DXA for the Cost-Conscious Practice
Lumbar Spine 90s 0.07mGy Central, Hong Kong
Proximal Femur 90s 0.07mGy Fax: 781.280.0668 1930 Zaventem, Belgium Tel: 852.3102.9200
Standard Software Configuration: www.hologic.com Tel: 32.2.711.4680 Fax: 1.425.696.7846
Whole Body 6.7min 0.011mGy
QDR for Windows® XP Operating System, Tech Tips™, Express Exam, Fax: 32.2.725.2087
*50Hz and other scan modes available
NHANES Reference Data, QDR OnePage Report, Context Sensitive
B-145 US/International (1/04) © Hologic 2004. All rights reserved. Printed in USA. Specifications are subject to change without prior notice. Hologic and Hologic logos, QDR, Discovery, OnePass, Express BMD, Express
Help, Fracture Risk Indication, OneTime™ Auto Analysis, Auto Low Exam, QDR Mobility, IRIS, OnePage Dx Report, Tech Tips, DXA Practice Manager, OneTime Auto Analysis, Dual Hip, A Hologic Company, are trademarks or registered trademarks of Hologic, Inc., in the United States an