Gravity loads are the vertical forces that act on a structure to include dead,
or permanent load, which is the weight of the structure, including its walls,
floors, finishes, and mechanical systems, and live, or temporary or moving
load, which is the weight of a structure's contents and occupants, including the
weight of snow.
The types of loads acting on structures for buildings and other structures can be
broadly classified as vertical loads, horizontal loads and longitudinal loads.
The vertical loads consist of dead load, live load and impact load. The horizontal
loads comprise of wind load and earthquake load.
Vertical loads, or gravity loads, are those forces that are applied
perpendicular to the roof or floor system.
Dead load
20.4-26.5
2 Stone Masonry
kN/m3
Live loads
Loads imposed on a structure that are made up by the people who use
the structure and what they decide to place in the structure
(furniture/storage etc.). Live loads are harder to predict than dead loads,
as it’s never possible to predict exactly how many people will be using a
space at a given time or how they will layout furniture and store materials
in a given space.
Live loads are either movable or moving loads without any acceleration or
impact. These loads are assumed to be produced by the intended use or
occupancy of the building including weights of movable partitions or furniture etc.
Live loads keep on changing from time to time. These loads are to be suitably
assumed by the designer. It is one of the major loads in the design. The
minimum values of live loads to be assumed are given in IS 875 (part 2)–1987. It
depends upon the intended use of the building.
The code gives the values of live loads for the following occupancy
classification:
The code gives uniformly distributed load as well as concentrated loads. The
floor slabs have to be designed to carry either uniformly distributed loads or
concentrated loads whichever produce greater stresses in the part under
consideration. Since it is unlikely that any one particular time all floors will not be
simultaneously carrying maximum loading, the code permits some reduction in
imposed loads in designing columns, load-bearing walls, piers supports
and foundations. Some of the important values are presented in table below
which are the minimum values and wherever necessary more than these values
are to be assumed.
1 0
2 10
3 20
4 30
5-10 40
Over 10 50