You are on page 1of 36

GE Healthcare

Chilin 19" Color LCD Monitor Option Installation


Service Documentation

5178234-100
Rev 2
© 2006-2007, General Electric Company,
All Rights Reserved.
GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

Page 2
GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

LEGAL NOTES

TRADEMARKS
Adobe, the Adobe logo, Acrobat, the Acrobat logo, Exchange, and PostScript are trademarks of
Adobe Systems Incorporated or its subsidiaries and may be registered in certain jurisdictions.
Microsoft is a registered trademark and Windows is a trademark of Microsoft Corporation.
All other products and their name brands are trademarks of their respective holders.

COPYRIGHTS
All Material, Copyright © 2006-2007 by General Electric Company, Inc. All rights reserved.

Legal Notes Page 3


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

Page 4 Legal Notes


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

IMPORTANT PRECAUTIONS

LANGUAGE

• 本维修手册仅提供英文版本。
警告
• 如果维修服务提供商需要非英文版本,客户需自行提供翻译服务。
(ZH-CN)
• 未详细阅读和完全理解本维修手册之前,不得进行维修。
• 忽略本警告可能对维修人员,操作员或患者造成触电、机械伤害或其他形式的伤害。

• TENTO PROVOZNÍ NÁVOD EXISTUJE POUZE V ANGLICKÉM JAZYCE.


VÝSTRAHA
• V PŘÍPADĚ, ŽE EXTERNÍ SLUŽBA ZÁKAZNÍKŮM POTŘEBUJE NÁVOD V
(CS)
JINÉM JAZYCE, JE ZAJIŠTĚNÍ PŘEKLADU DO ODPOVÍDAJÍCÍHO JAZYKA
ÚKOLEM ZÁKAZNÍKA.
• NESNAŽTE SE O ÚDRŽBU TOHOTO ZAŘÍZENÍ, ANIŽ BYSTE SI PŘEČETLI
TENTO PROVOZNÍ NÁVOD A POCHOPILI JEHO OBSAH.
• V PŘÍPADĚ NEDODRŽOVÁNÍ TÉTO VÝSTRAHY MŮŽE DOJÍT K PORANĚNÍ
PRACOVNÍKA PRODEJNÍHO SERVISU, OBSLUŽNÉHO PERSONÁLU NEBO
PACIENTŮ VLIVEM ELEKTRICKÉHOP PROUDU, RESPEKTIVE VLIVEM
MECHANICKÝCH ČI JINÝCH RIZIK.

ADVARSEL • DENNE SERVICEMANUAL FINDES KUN PÅ ENGELSK.

(DA) • HVIS EN KUNDES TEKNIKER HAR BRUG FOR ET ANDET SPROG END
ENGELSK, ER DET KUNDENS ANSVAR AT SØRGE FOR OVERSÆTTELSE.
• FORSØG IKKE AT SERVICERE UDSTYRET MEDMINDRE
DENNE SERVICEMANUAL HAR VÆRET KONSULTERET OG ER FORSTÅET.
• MANGLENDE OVERHOLDELSE AF DENNE ADVARSEL KAN MEDFØRE
SKADE PÅ GRUND AF ELEKTRISK, MEKANISK ELLER ANDEN FARE FOR
TEKNIKEREN, OPERATØREN ELLER PATIENTEN.

• DEZE ONDERHOUDSHANDLEIDING IS ENKEL IN HET ENGELS


WAARSCHUWING VERKRIJGBAAR.
(NL)
• ALS HET ONDERHOUDSPERSONEEL EEN ANDERE TAAL VEREIST, DAN IS
DE KLANT VERANTWOORDELIJK VOOR DE VERTALING ERVAN.
• PROBEER DE APPARATUUR NIET TE ONDERHOUDEN VOORDAT DEZE
ONDERHOUDSHANDLEIDING WERD GERAADPLEEGD EN BEGREPEN IS.
• INDIEN DEZE WAARSCHUWING NIET WORDT OPGEVOLGD, ZOU HET
ONDERHOUDSPERSONEEL, DE OPERATOR OF EEN PATIËNT GEWOND
KUNNEN RAKEN ALS GEVOLG VAN EEN ELEKTRISCHE SCHOK,
MECHANISCHE OF ANDERE GEVAREN.

IMPORTANT PRECAUTIONS Page 5


GE HEALTHCARE CT/E DUAL, PROSPEED AII/FII SERIES
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

• THIS SERVICE MANUAL IS AVAILABLE IN ENGLISH ONLY.


WARNING
• IF A CUSTOMER’S SERVICE PROVIDER REQUIRES A LANGUAGE
(EN) OTHER THAN ENGLISH, IT IS THE CUSTOMER’S RESPONSIBILITY TO
PROVIDE TRANSLATION SERVICES.
• DO NOT ATTEMPT TO SERVICE THE EQUIPMENT UNLESS THIS
SERVICE MANUAL HAS BEEN CONSULTED AND IS UNDERSTOOD.
• FAILURE TO HEED THIS WARNING MAY RESULT IN INJURY TO THE
SERVICE PROVIDER, OPERATOR OR PATIENT FROM ELECTRIC
SHOCK, MECHANICAL OR OTHER HAZARDS.

HOIATUS • KÄESOLEV TEENINDUSJUHEND ON SAADAVAL AINULT INGLISE KEELES.

(ET) • KUI KLIENDITEENINDUSE OSUTAJA NÕUAB JUHENDIT INGLISE KEELEST


ERINEVAS KEELES, VASTUTAB KLIENT TÕLKETEENUSE OSUTAMISE EEST.
• ÄRGE ÜRITAGE SEADMEID TEENINDADA ENNE EELNEVALT
KÄESOLEVA TEENINDUSJUHENDIGA TUTVUMIST JA SELLEST ARU
SAAMIST.
• KÄESOLEVA HOIATUSE EIRAMINE VÕIB PÕHJUSTADA TEENUSEOSUTAJA,
OPERAATORI VÕI PATSIENDI VIGASTAMIST ELEKTRILÖÖGI, MEHAANILISE
VÕI MUU OHU TAGAJÄRJEL.

• TÄMÄ HUOLTO-OHJE ON SAATAVILLA VAIN ENGLANNIKSI.


VAROITUS
• JOS ASIAKKAAN HUOLTOHENKILÖSTÖ VAATII MUUTA KUIN
(FI)
ENGLANNINKIELISTÄ MATERIAALIA, TARVITTAVAN KÄÄNNÖKSEN
HANKKIMINEN ON ASIAKKAAN VASTUULLA.
• ÄLÄ YRITÄ KORJATA LAITTEISTOA ENNEN KUIN OLET VARMASTI LUKENUT
JA YMMÄRTÄNYT TÄMÄN HUOLTO-OHJEEN.
• MIKÄLI TÄTÄ VAROITUSTA EI NOUDATETA, SEURAUKSENA VOI OLLA
HUOLTOHENKILÖSTÖN, LAITTEISTON KÄYTTÄJÄN TAI POTILAAN
VAHINGOITTUMINEN SÄHKÖISKUN, MEKAANISEN VIAN TAI MUUN
VAARATILANTEEN VUOKSI.

• CE MANUEL DE MAINTENANCE N’EST DISPONIBLE QU’EN ANGLAIS.


ATTENTION
• SI LE TECHNICIEN DU CLIENT A BESOIN DE CE MANUEL DANS UNE
(FR)
AUTRE LANGUE QUE L’ANGLAIS, C’EST AU CLIENT QU’IL INCOMBE
DE LE FAIRE TRADUIRE.
• NE PAS TENTER D’INTERVENTION SUR LES ÉQUIPEMENTS TANT
QUE LE MANUEL SERVICE N’A PAS ÉTÉ CONSULTÉ ET COMPRIS.
• LE NON-RESPECT DE CET AVERTISSEMENT PEUT ENTRAÎNER CHEZ
LE TECHNICIEN, L’OPÉRATEUR OU LE PATIENT DES BLESSURES
DUES À DES DANGERS ÉLECTRIQUES, MÉCANIQUES OU AUTRES.

Page 6 IMPORTANT PRECAUTIONS


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

• DIESE SERVICEANLEITUNG EXISTIERT NUR IN ENGLISCHER SPRACHE.


WARNUNG
(DE) • FALLS EIN FREMDER KUNDENDIENST EINE ANDERE SPRACHE BENÖTIGT,
IST ES AUFGABE DES KUNDEN FÜR EINE ENTSPRECHENDE
ÜBERSETZUNG ZU SORGEN.
• VERSUCHEN SIE NICHT DIESE ANLAGE ZU WARTEN,
OHNE DIESE SERVICEANLEITUNG GELESEN UND VERSTANDEN ZU HABEN.
• WIRD DIESE WARNUNG NICHT BEACHTET, SO KANN ES ZU
VERLETZUNGEN DES KUNDENDIENSTTECHNIKERS, DES BEDIENERS ODER
DES PATIENTEN DURCH STROMSCHLÄGE, MECHANISCHE ODER SONSTIGE
GEFAHREN KOMMEN.

ΠΡΟΕΙΔΟΠΟΙΗΣΗ • ΤΟ ΠΑΡΟΝ ΕΓΧΕΙΡΙΔΙΟ ΣΕΡΒΙΣ ΔΙΑΤΙΘΕΤΑΙ ΣΤΑ ΑΓΓΛΙΚΑ ΜΟΝΟ.

(EL) • ΕΑΝ ΤΟ ΑΤΟΜΟ ΠΑΡΟΧΗΣ ΣΕΡΒΙΣ ΕΝΟΣ ΠΕΛΑΤΗ ΑΠΑΙΤΕΙ ΤΟ ΠΑΡΟΝ


ΕΓΧΕΙΡΙΔΙΟ ΣΕ ΓΛΩΣΣΑ ΕΚΤΟΣ ΤΩΝ ΑΓΓΛΙΚΩΝ, ΑΠΟΤΕΛΕΙ ΕΥΘΥΝΗ ΤΟΥ
ΠΕΛΑΤΗ ΝΑ ΠΑΡΕΧΕΙ ΥΠΗΡΕΣΙΕΣ ΜΕΤΑΦΡΑΣΗΣ.
• ΜΗΝ ΕΠΙΧΕΙΡΗΣΕΤΕ ΤΗΝ ΕΚΤΕΛΕΣΗ ΕΡΓΑΣΙΩΝ ΣΕΡΒΙΣ ΣΤΟΝ ΕΞΟΠΛΙΣΜΟ
ΕΚΤΟΣ ΕΑΝ ΕΧΕΤΕ ΣΥΜΒΟΥΛΕΥΤΕΙ ΚΑΙ ΕΧΕΤΕ ΚΑΤΑΝΟΗΣΕΙ ΤΟ ΠΑΡΟΝ
ΕΓΧΕΙΡΙΔΙΟ ΣΕΡΒΙΣ.
• ΕΑΝ ΔΕ ΛΑΒΕΤΕ ΥΠΟΨΗ ΤΗΝ ΠΡΟΕΙΔΟΠΟΙΗΣΗ ΑΥΤΗ, ΕΝΔΕΧΕΤΑΙ ΝΑ
ΠΡΟΚΛΗΘΕΙ ΤΡΑΥΜΑΤΙΣΜΟΣ ΣΤΟ ΑΤΟΜΟ ΠΑΡΟΧΗΣ ΣΕΡΒΙΣ, ΣΤΟ ΧΕΙΡΙΣΤΗ
Ή ΣΤΟΝ ΑΣΘΕΝΗ ΑΠΟ ΗΛΕΚΤΡΟΠΛΗΞΙΑ, ΜΗΧΑΝΙΚΟΥΣ Ή ΑΛΛΟΥΣ
ΚΙΝΔΥΝΟΥΣ.

• EZEN KARBANTARTÁSI KÉZIKÖNYV KIZÁRÓLAG ANGOL NYELVEN ÉRHETŐ


FIGYELMEZTETÉS EL.
(HU)
• HA A VEVŐ SZOLGÁLTATÓJA ANGOLTÓL ELTÉRŐ NYELVRE TART IGÉNYT,
AKKOR A VEVŐ FELELŐSSÉGE A FORDÍTÁS ELKÉSZÍTTETÉSE.
• NE PRÓBÁLJA ELKEZDENI HASZNÁLNI A BERENDEZÉST, AMÍG A
KARBANTARTÁSI KÉZIKÖNYVBEN LEÍRTAKAT NEM ÉRTELMEZTÉK.
• EZEN FIGYELMEZTETÉS FIGYELMEN KÍVÜL HAGYÁSA A SZOLGÁLTATÓ,
MŰKÖDTETŐ VAGY A BETEG ÁRAMÜTÉS, MECHANIKAI VAGY EGYÉB
VESZÉLYHELYZET MIATTI SÉRÜLÉSÉT EREDMÉNYEZHETI.

• ÞESSI ÞJÓNUSTUHANDBÓK ER EINGÖNGU FÁANLEG Á ENSKU.


AÐVÖRUN
(IS) • EF AÐ ÞJÓNUSTUVEITANDI VIÐSKIPTAMANNS ÞARFNAST ANNAS
TUNGUMÁLS EN ENSKU, ER ÞAÐ SKYLDA VIÐSKIPTAMANNS AÐ SKAFFA
TUNGUMÁLAÞJÓNUSTU.
• REYNIÐ EKKI AÐ AFGREIÐA TÆKIÐ NEMA AÐ ÞESSI ÞJÓNUSTUHANDBÓK
HEFUR VERIÐ SKOÐUÐ OG SKILIN.
• BROT Á SINNA ÞESSARI AÐVÖRUN GETUR LEITT TIL MEIÐSLA Á
ÞJÓNUSTUVEITANDA, STJÓRNANDA EÐA SJÚKLINGS FRÁ RAFLOSTI,
VÉLRÆNU EÐA ÖÐRUM ÁHÆTTUM.

IMPORTANT PRECAUTIONS Page 7


GE HEALTHCARE CT/E DUAL, PROSPEED AII/FII SERIES
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

• IL PRESENTE MANUALE DI MANUTENZIONE È DISPONIBILE


AVVERTENZA SOLTANTO IN INGLESE.
(IT)
• SE UN ADDETTO ALLA MANUTENZIONE ESTERNO ALLA GEMS
RICHIEDE IL MANUALE IN UNA LINGUA DIVERSA, IL CLIENTE È
TENUTO A PROVVEDERE DIRETTAMENTE ALLA TRADUZIONE.
• SI PROCEDA ALLA MANUTENZIONE DELL’APPARECCHIATURA
SOLO DOPO AVER CONSULTATO IL PRESENTE MANUALE ED
AVERNE COMPRESO IL CONTENUTO.
• IL NON RISPETTO DELLA PRESENTE AVVERTENZA POTREBBE FAR
COMPIERE OPERAZIONI DA CUI DERIVINO LESIONI ALL’ADDETTO
ALLA MANUTENZIONE, ALL’UTILIZZATORE ED AL PAZIENTE PER
FOLGORAZIONE ELETTRICA, PER URTI MECCANICI OD ALTRI
RISCHI.

• このサービスマニュアルには英語版しかありません。

• サービスを担当される業者が英語以外の言語を要求される場合、翻訳作業はその業
(JA) 者の責任で行うものとさせていただきます。

• このサービスマニュアルを熟読し理解せずに、装置のサービスを行わないでくださ
い。

• この警告に従わない場合、サービスを担当される方、操作員あるいは患者さんが、
感電や機械的又はその他の危険により負傷する可能性があります。

• 본 서비스 지침서는 영어로만 이용하실 수 있습니다.


경고 • 고객의 서비스 제공자가 영어 이외의 언어를 요구할 경우, 번역 서비스를 제공하는 것
(KO) 은 고객의 책임입니다.

• 본 서비스 지침서를 참고했고 이해하지 않는 한은 해당 장비를 수리하려고 시도하지


마십시오.

• 이 경고에 유의하지 않으면 전기 쇼크, 기계상의 혹은 다른 위험으로부터 서비스 제공


자, 운영자 혹은 환자에게 위해를 가할 수 있습니다.

Page 8 IMPORTANT PRECAUTIONS


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

• ŠĪ APKALPES ROKASGRĀMATA IR PIEEJAMA TIKAI ANGĻU VALODĀ.


BRĪDINĀJUMS
(LV) • JA KLIENTA APKALPES SNIEDZĒJAM NEPIECIEŠAMA INFORMĀCIJA CITĀ
VALODĀ, NEVIS ANGĻU, KLIENTA PIENĀKUMS IR NODROŠINĀT
TULKOŠANU.
• NEVEICIET APRĪKOJUMA APKALPI BEZ APKALPES ROKASGRĀMATAS
IZLASĪŠANAS UN SAPRAŠANAS.
• ŠĪ BRĪDINĀJUMA NEIEVĒROŠANA VAR RADĪT ELEKTRISKĀS STRĀVAS
TRIECIENA, MEHĀNISKU VAI CITU RISKU IZRAISĪTU TRAUMU APKALPES
SNIEDZĒJAM, OPERATORAM VAI PACIENTAM.

ĮSPĖJIMAS • ŠIS EKSPLOATAVIMO VADOVAS YRA PRIEINAMAS TIK ANGLŲ KALBA.

(LT) • JEI KLIENTO PASLAUGŲ TIEKĖJAS REIKALAUJA VADOVO KITA KALBA – NE


ANGLŲ, NUMATYTI VERTIMO PASLAUGAS YRA KLIENTO ATSAKOMYBĖ.
• NEMĖGINKITE ATLIKTI ĮRANGOS TECHNINĖS PRIEŽIŪROS, NEBENT
ATSIŽVELGĖTE Į ŠĮ EKSPLOATAVIMO VADOVĄ IR JĮ SUPRATOTE.
• JEI NEATKREIPSITE DĖMESIO Į ŠĮ PERSPĖJIMĄ, GALIMI SUŽALOJIMAI DĖL
ELEKTROS ŠOKO.
• MECHANINIŲ AR KITŲ PAVOJŲ PASLAUGŲ TIEKĖJUI, OPERATORIUI AR
PACIENTUI.

• DENNE SERVICEHÅNDBOKEN FINNES BARE PÅ ENGELSK.


ADVARSEL
(NO) • HVIS KUNDENS SERVICELEVERANDØR TRENGER ET ANNET SPRÅK, ER
DET KUNDENS ANSVAR Å SØRGE FOR OVERSETTELSE.
• IKKE FORSØK Å REPARERE UTSTYRET UTEN AT DENNE
SERVICEHÅNDBOKEN ER LEST OG FORSTÅTT.
• MANGLENDE HENSYN TIL DENNE ADVARSELEN KAN FØRE TIL AT
SERVICELEVERANDØREN, OPERATØREN ELLER PASIENTEN SKADES PÅ
GRUNN AV ELEKTRISK STØT, MEKANISKE ELLER ANDRE FARER.

• NINIEJSZY PODRĘCZNIK SERWISOWY DOSTĘPNY JEST JEDYNIE W JĘZYKU


OSTRZEŻENIE ANGIELSKIM.
(PL)
• JEŚLI DOSTAWCA USŁUG KLIENTA WYMAGA JĘZYKA INNEGO NIŻ
ANGIELSKI, ZAPEWNIENIE USŁUGI TŁUMACZENIA JEST OBOWIĄZKIEM
KLIENTA.
• NIE PRÓBOWAĆ SERWISOWAĆ WYPOSAŻENIA BEZ ZAPOZNANIA SIĘ I
ZROZUMIENIA NINIEJSZEGO PODRĘCZNIKA SERWISOWEGO.
• NIEZASTOSOWANIE SIĘ DO TEGO OSTRZEŻENIA MOŻE SPOWODOWAĆ
URAZY DOSTAWCY USŁUG, OPERATORA LUB PACJENTA W WYNIKU
PORAŻENIA ELEKTRYCZNEGO, ZAGROŻENIA MECHANICZNEGO BĄDŹ
INNEGO.

IMPORTANT PRECAUTIONS Page 9


GE HEALTHCARE CT/E DUAL, PROSPEED AII/FII SERIES
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

• ESTE MANUAL DE ASSISTÊNCIA TÉCNICA SÓ SE ENCONTRA DISPONÍVEL


ATENÇÃO EM INGLÊS.
(PT)
• SE QUALQUER OUTRO SERVIÇO DE ASSISTÊNCIA TÉCNICA, QUE NÃO A
GEMS, SOLICITAR ESTES MANUAIS NOUTRO IDIOMA, É DA
RESPONSABILIDADE DO CLIENTE FORNECER OS SERVIÇOS DE
TRADUÇÃO.
• NÃO TENTE REPARAR O EQUIPAMENTO SEM TER CONSULTADO E
COMPREENDIDO ESTE MANUAL DE ASSISTÉNCIA TÉCNICA
• O NÃO CUMPRIMENTO DESTE AVISO PODE POR EM PERIGO A SEGURANÇA
DO TÉCNICO, OPERADOR OU PACIENTE DEVIDO A CHOQUES ELÉTRICOS,
MECÂNICOS OU OUTROS.

• ACEST MANUAL DE SERVICE ESTE DISPONIBIL NUMAI ÎN LIMBA ENGLEZĂ.


ATENŢIE
(RO) • DACĂ UN FURNIZOR DE SERVICII PENTRU CLIENŢI NECESITĂ O ALTĂ
LIMBĂ DECÂT CEA ENGLEZĂ, ESTE DE DATORIA CLIENTULUI SĂ
FURNIZEZE O TRADUCERE.
• NU ÎNCERCAŢI SĂ REPARAŢI ECHIPAMENTUL DECÂT ULTERIOR
CONSULTĂRII ŞI ÎNŢELEGERII ACESTUI MANUAL DE SERVICE.
• IGNORAREA ACESTUI AVERTISMENT AR PUTEA DUCE LA RĂNIREA
DEPANATORULUI, OPERATORULUI SAU PACIENTULUI ÎN URMA
PERICOLELOR DE ELECTROCUTARE, MECANICE SAU DE ALTĂ NATURĂ.

• ДАННОЕ РУКОВОДСТВО ПО ОБСЛУЖИВАНИЮ ПРЕДЛАГАЕТСЯ ТОЛЬКО


ОСТОРОЖНО! НА АНГЛИЙСКОМ ЯЗЫКЕ.
(RU)
• ЕСЛИ СЕРВИСНОМУ ПЕРСОНАЛУ КЛИЕНТА НЕОБХОДИМО
РУКОВОДСТВО НЕ НА АНГЛИЙСКОМ, А НА КАКОМ-ТО ДРУГОМ ЯЗЫКЕ,
КЛИЕНТУ СЛЕДУЕТ САМОСТОЯТЕЛЬНО ОБЕСПЕЧИТЬ ПЕРЕВОД.
• ПЕРЕД ОБСЛУЖИВАНИЕМ ОБОРУДОВАНИЯ ОБЯЗАТЕЛЬНО
ОБРАТИТЕСЬ К ДАННОМУ РУКОВОДСТВУ И ПОЙМИТЕ ИЗЛОЖЕННЫЕ В
НЕМ СВЕДЕНИЯ.
• НЕСОБЛЮДЕНИЕ ТРЕБОВАНИЙ ДАННОГО ПРЕДУПРЕЖДЕНИЯ МОЖЕТ
ПРИВЕСТИ К ТОМУ, ЧТО СПЕЦИАЛИСТ ПО ОБСЛУЖИВАНИЮ, ОПЕРАТОР
ИЛИ ПАЦИЕНТ ПОЛУЧАТ УДАР ЭЛЕКТРИЧЕСКИМ ТОКОМ,
МЕХАНИЧЕСКУЮ ТРАВМУ ИЛИ ДРУГОЕ ПОВРЕЖДЕНИЕ.

• TENTO NÁVOD NA OBSLUHU JE K DISPOZÍCII LEN V ANGLIČTINE.


UPOZORNENIE
• AK ZÁKAZNÍKOV POSKYTOVATEĽ SLUŽIEB VYŽADUJE INÝ JAZYK AKO
(SK)
ANGLIČTINU, POSKYTNUTIE PREKLADATEĽSKÝCH SLUŽIEB JE
ZODPOVEDNOSŤOU ZÁKAZNÍKA.
• NEPOKÚŠAJTE SA O OBSLUHU ZARIADENIA SKÔR, AKO SI NEPREČÍTATE
NÁVOD NA OBLUHU A NEPOROZUMIETE MU.
• ZANEDBANIE TOHTO UPOZORNENIA MÔŽE VYÚSTIŤ DO ZRANENIA
POSKYTOVATEĽA SLUŽIEB, OBSLUHUJÚCEJ OSOBY ALEBO PACIENTA
ELEKTRICKÝM PRÚDOM, DO MECHANICKÉHO ALEBO INÉHO
NEBEZPEČENSTVA.

Page 10 IMPORTANT PRECAUTIONS


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

• ESTE MANUAL DE SERVICIO SOLO EXISTE EN INGLES.


ATENCION
• SI ALGUN PROVEEDOR DE SERVICIOS AJENO A GEMS SOLICITA UN IDIOMA
(ES)
QUE NO SEA EL INGLES, ES RESPONSABILIDAD DEL CLIENTE OFRECER UN
SERVICIO DE TRADUCCION.
• NO SE DEBERA DAR SERVICIO TECNICO AL EQUIPO,
SIN HABER CONSULTADO Y COMPRENDIDO ESTE MANUAL DE SERVICIO.
• LA NO OBSERVANCIA DEL PRESENTE AVISO PUEDE DAR LUGAR A QUE EL
PROVEEDOR DE SERVICIOS, EL OPERADOR O EL PACIENTE SUFRAN
LESIONES PROVOCADAS POR CAUSAS ELÉCTRICAS, MECÁNICAS O DE
OTRA NATURALEZA.

• DEN HÄR SERVICEHANDBOKEN FINNS BARA TILLGÄNGLIG PÅ ENGELSKA.


VARNING
• OM EN KUNDS SERVICETEKNIKER HAR BEHOV AV ETT ANNAT SPRÅK ÄN
(SV) ENGELSKA ANSVARAR KUNDEN FÖR ATT TILLHANDAHÅLLA
ÖVERSÄTTNINGSTJÄNSTER.
• FÖRSÖK INTE UTFÖRA SERVICE PÅ UTRUSTNINGEN OM DU INTE HAR LÄST
OCH FÖRSTÅR DEN HÄR SERVICEHANDBOKEN.
• OM DU INTE TAR HÄNSYN TILL DEN HÄR VARNINGEN KAN DET RESULTERA
I SKADOR PÅ SERVICETEKNIKERN, OPERATÖREN ELLER PATIENTEN TILL
FÖLJD AV ELEKTRISKA STÖTAR, MEKANISKA FAROR ELLER ANDRA
FAROR.

• BU SERVİS KILAVUZUNUN SADECE İNGİLİZCESİ MEVCUTTUR.


DİKKAT
• EĞER MÜŞTERİ TEKNİSYENİ BU KILAVUZU İNGİLİZCE DIŞINDA BİR BAŞKA
(TR)
LİSANDAN TALEP EDERSE, BUNU TERCÜME ETTİRMEK MÜŞTERİYE DÜŞER.
• SERVİS KILAVUZUNU OKUYUP ANLAMADAN EKİPMANLARA MÜDAHALE
ETMEYİNİZ.
• BU UYARIYA UYULMAMASI, ELEKTRİK, MEKANİK VEYA DİĞER
TEHLİKELERDEN DOLAYI TEKNİSYEN, OPERATÖR VEYA HASTANIN
YARALANMASINA YOL AÇABİLİR.

IMPORTANT PRECAUTIONS Page 11


GE HEALTHCARE CT/E DUAL, PROSPEED AII/FII SERIES
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION
DAMAGE IN TRANSPORTATION
All packages should be closely examined at time of delivery. If damage is apparent write “Damage
In Shipment” on ALL copies of the freight or express bill BEFORE delivery is accepted or “signed
for” by a GE representative or hospital receiving agent. Whether noted or concealed, damage
MUST be reported to the carrier immediately upon discovery, or in any event, within 14 days after
receipt, and the contents and containers held for inspection by the carrier. A transportation
company will not pay a claim for damage if an inspection is not requested within this 14 day period.
To file a report:
Fill out a report on http://egems.med.ge.com/edq/home.jsp
Contact the local service coordinator.

CERTIFIED ELECTRICAL CONTRACTOR STATEMENT


All electrical Installations that are preliminary to positioning of the equipment at the site prepared
for the equipment shall be performed by licensed electrical contractors. In addition, electrical feeds
into the Power Distribution Unit shall be performed by licensed electrical contractors. Other
connections between pieces of electrical equipment, calibrations and testing shall be performed by
qualified GE Medical personnel. The products involved (and the accompanying electrical
installations) are highly sophisticated, and special engineering competence is required. In
performing all electrical work on these products, GE will use its own specially trained field
engineers. All of GE’s electrical work on these products will comply with the requirements of the
applicable electrical codes.
The purchaser of GE equipment shall only utilize qualified personnel (i.e., GE’s field engineers,
personnel of third-party service companies with equivalent training, or licensed electricians) to
perform electrical servicing on the equipment.

IMPORTANT...X-RAY PROTECTION
X-ray equipment if not properly used may cause injury. Accordingly, the instructions herein
contained should be thoroughly read and understood by everyone who will use the equipment
before you attempt to place this equipment in operation. The General Electric Company, Medical
Systems Group, will be glad to assist and cooperate in placing this equipment in use.
Although this apparatus incorporates a high degree of protection against x-radiation other than the
useful beam, no practical design of equipment can provide complete protection. Nor can any
practical design compel the operator to take adequate precautions to prevent the possibility of any
persons carelessly exposing themselves or others to radiation.
It is important that anyone having anything to do with x-radiation be properly trained and fully
acquainted with the recommendations of the National Council on Radiation Protection and
Measurements as published in NCRP Reports available from NCRP Publications, 7910 Woodmont
Avenue, Room 1016, Bethesda, Maryland 20814, and of the International Commission on
Radiation Protection, and take adequate steps to protect against injury.
The equipment is sold with the understanding that the General Electric Company, Medical Systems
Group, its agents, and representatives have no responsibility for injury or damage which may result
from improper use of the equipment.
Various protective materials and devices are available. It is urged that such materials or devices be
used.

LITHIUM BATTERY CAUTIONARY STATEMENTS

CAUTION Danger of explosion if battery is incorrectly replaced. Replace only with the same or
Risk of equivalent type recommended by the manufacturer. Discard used batteries according to the
Explosion manufacturer’s instructions.

Page 12 IMPORTANT PRECAUTIONS


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

ATTENTION Il y a danger d’explosion s’il y a replacement incorrect de la batterie. Remplacer uniquement


Danger avec une batterie du même type ou d’un type recommandé par le constructeur. Mettre au
d’Explosion rébut les batteries usagées conformément aux instructions du fabricant.

OMISSIONS & ERRORS


Customers, please contact your GE Sales or Service representatives.
GE personnel, please use the GEMS CQA Process to report all omissions, errors, and defects in
this publication.

IMPORTANT PRECAUTIONS Page 13


GE HEALTHCARE CT/E DUAL, PROSPEED AII/FII SERIES
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

Page 14 IMPORTANT PRECAUTIONS


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

Revision History

Revision History
Revision Date Reason for change
1 10/25/06 initial release.
2 06/07/06 Added Section 4 Disposal: warning for statement about Hg in device.

Revision History Page 15


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

Page 16 Revision History


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

Table of Contents
Chapter 1
Introduction............................................................................................................ 19
Section 1.0
System Requirement........................................................................................ 19
Section 2.0
Material List ...................................................................................................... 19

Table of Contents
Section 3.0
Flowchart .......................................................................................................... 20

Chapter 2
Installation Procedure........................................................................................... 21
Section 1.0
Overview ........................................................................................................... 21
Section 2.0
Installation Procedure...................................................................................... 21
2.1 EXISTING MONITOR REMOVAL (IF THERE IS A MONITOR TO BE REPLACED)...... 21
2.2 Monitor Connection.......................................................................................................... 21
2.3 General Procedures for Setup ......................................................................................... 26
2.3.1 OSD (On-Screen-Display) Controls.................................................................... 26
2.3.2 Main Menu .......................................................................................................... 27
2.3.3 OSD Function ..................................................................................................... 27
2.3.4 Lock Mode Explain ............................................................................................. 29
2.3.5 Hot Key Controls................................................................................................. 30
2.3.6 Contrast and Brightness Minor Adjustment ........................................................ 31
Section 3.0
Function Check ................................................................................................ 32
Section 4.0
Disposal ............................................................................................................ 32

Chapter 3
Finish Installation .................................................................................................. 33
Section 1.0
Attach Rating Plate .......................................................................................... 33
Section 2.0
Return Installation Card................................................................................... 34

Table of Contents Page 17


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

Page 18 Table of Contents


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 1 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

Chapter 1
Introduction

Section 1.0
System Requirement
This option is available for all Systems.

Section 2.0
Material List

1 - Introduction
Verify that the contents of this option kit are correct according to the Material List below.
Chilin 19" Color LCD Monitor Option Kit (5128434-2)

ITEM PART NO. DESCRIPTION QTY.


1 5178602 Chilin 19" Color LCD Monitor 1

2 2111577 Rating Plate 1

3 5178234-100 Option Installation Manual (This Manual) 1

Chilin 19" Color LCD Monitor Option Kit_Black (5128434-3)

ITEM PART NO. DESCRIPTION QTY.


1 5178602-2 Chilin 19" Color LCD Monitor - Black 1

2 2111577 Rating Plate 1

3 5178234-100 Option Installation Manual (This Manual) 1

Chapter 1 - Introduction Page 19


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 1 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

Section 3.0
Flowchart
The Illustration below shows the main flow of the installation procedures of the option.
START

Preparation

Monitor Installation

Functional Check

END

Page 20 Section 3.0 - Flowchart


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

Chapter 2
Installation Procedure

Section 1.0
Overview
This instruction describes the hardware installation procedure.

Section 2.0
Installation Procedure
2.1 EXISTING MONITOR REMOVAL (IF THERE IS A MONITOR TO BE

2 – INSTALLATION
REPLACED)

PROCEDURE
Understand and follow the Safety Guidelines Manual.
1.) Turn OFF the Operator Console main power.
2.) Turn OFF the breaker in the Power Distribution Box (hospital supply).
3.) Remove the OC Rear Cover.
4.) Disconnect the Signal and Power cables connected from the monitor to the OC.
5.) Remove the monitor from the OC (or OC table).

2.2 Monitor Connection

1.) Unpack the LCD monitor and place it on the OC.


2.) Route and connect the cables as below illustrations.

Note: For each LCD Monitor we supply two different kinds of Signal Cables. Check the ports of the
Display Board before connecting the Signal Cables. Select proper Signal Cable to connect
the proper port on the LCD according to different ports of the Display Board.
Figure 2-1 Signal Cable

DVI VGA DVI


DVI

VGA
VGA

Chapter 2 - Installation Procedure Page 21


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION
• For CT/e, CT ProSpeed AI/FI Series and CT/e Dual, ProSpeed AII/FII Series
• For HiSpeed Dual (Big OC)
• For ProSpeed FII (Small OC)
• For BrightSpeed Series and RT16, Xtra; LS RT

• For CT/e, CT ProSpeed AI/FI Series and CT/e Dual, ProSpeed AII/FII Series
a.) Connect the Power cable to the AC Power Supply Assy (or AC Box).
b.) Reinstall the Rear Cover.
c.) Connect the signal cable to the VSPL (Video Board).
d.) Reinstall the Rear Connector Cover.
Figure 2-2 AC Power Cable and Signal Cable Replacement

Connect the Monitor


AC PS Assy 1 Power cable to the AC
(rear view) PS Assy

Video Board

Monitor

Slave Monitor

Rear
Connector
Cover
Rear
Reinstall the Cover
4
Rear Connector Reinstall the AC PS Assy
2
Cover Rear Cover

Connect the Monitor


3
signal cable connector
(VGA VGA)

Page 22 Chapter 2 - Installation Procedure


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION
• For HiSpeed Dual (Big OC)
Figure 2-3 Cables Connection

Rear View
OC Rear View

DVI VGA

Power Cable

REAR CN2
DASIFN2
VGA VGA
VSPL Monitor Slave Monitor

REAR CN1 Signal Cable


(VGA VGA)

HOST ASSY

2 – INSTALLATION
PROCEDURE
Route the Power Cable through the hole
to connect the AC Box

Figure 2-4 Cables Connection (No VSPL)

Rear View
OC Rear View

DVI VGA

Power Cable
Signal Cable
(VGA DVI)

REAR CN2
DASIFN2

REAR CN1

DVI

HOST ASSY

Route the Power Cable through the hole


to connect the AC Box

Chapter 2 - Installation Procedure Page 23


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION
• For ProSpeed FII (Small OC)
Figure 2-5 Cables Connection

Rear View
OC Rear View

DVI VGA

Power Cable

VGA
Signal Cable
(VGA VGA)
VGA

REAR CN2

REAR CN1
DASIFN2
VSPL
Figure 2-6 Cables Connection (No VSPL)

Rear View
OC Rear View

DVI VGA

Power Cable

Signal Cable
(VGA DVI)
REAR CN2

REAR CN1
DASIFN2

Host PC
DVI

Page 24 Chapter 2 - Installation Procedure


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION
• For BrightSpeed Series and RT16, Xtra; LS RT
OC Rear View

Power Cable
Rear View Rear View

DVI VGA DVI VGA

Signal Cable
(DVI DVI or
VGA DVI)

Route the Power Cables thourgh


the hole to connect the Power Supply

HOST ASSY

DVI

DVI

2 – INSTALLATION
PROCEDURE
Display
Signal Cable
Connectors Scan

3.) Connect the signal cable and power cable to the LCD monitor.
Figure 2-7 Connect Cables to LCD Monitor
Note: Fix the Power Cable with metal clip

Power Cable Signal Cable

4.) Reinstall the OC Rear Cover.


5.) Turn ON the main switch located at the back of the LCD monitor.
Chapter 2 - Installation Procedure Page 25
GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

2.3 General Procedures for Setup

2.3.1 OSD (On-Screen-Display) Controls

Main Function Menu


[Power] Power Indicator
Green: Normal
Orange: Power Saving, No Signal
Off: Power Off
[Enter] Access and control the function of sub-menu
Quick input source selection. *

[>] Press the ">" to selection sub-menu items and increase adjustment
Quick gamma item selection. *
[<] Press the "<" to selection sub-menu items and decrease adjustment
Quick mode item selection. *
[Menu] Start the OSD feature
Exits the OSD controls
Exits the OSD sub-menu

* Refer to the Hot Key Controls Section.

OSD control buttons on the front of the monitor function as follows:


1.) Power on the LCD Medical Display.
2.) Press the "MENU" button to start the OSD feature.
3.) Press the ">" or "<" button to selection sub-menu items.
4.) Press the ">" or "<" button to increase/decrease adjustment.
5.) Press the "ENTER" button to access the function to be adjusted.
6.) To exit the OSD menu or go back to the previous action by clicking the "MENU" button. It will
save the change automatically.
7.) To repeat above steps for changing the setting of other functions.

Page 26 Chapter 2 - Installation Procedure


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

2.3.2 Main Menu

Options Menu
Color Menu
Image Menu OSD Menu
Display Menu
Display Menu Utility Menu

Brightness
Hue

Contrast Saturation

Operation
Explaining
OSD Control
Button State

2 – INSTALLATION
PROCEDURE
2.3.3 OSD Function

Primary Secondary Directory Description


Directory
Adjusts the background black level of the screen
Brightness
image.
Adjusts fore ground white level of the screen
Contrast
image.

Adjusts the purity and depth of the red, blue and


Hue
Display green of color.
Adjusts the saturation of the color.
Saturation

Automatically adjusts the Image Position and H.


Auto Adjust
size (or V. size) setting and Fine Settings.

Moves the image up and down on the screen.


Auto Color

Adjusts image distortion appearing as horizontal


Phase
"noise" on the screen.
Adjusts the clock pulse of the image.
Clock
Image
Moves the screen image left or right.
H-Position

Moves the screen image up or down.


V-Position

Chapter 2 - Installation Procedure Page 27


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

Primary Secondary Directory Description


Directory

Adjusts Gamma value.


Gamma

Selects color temperature.


Color Temp.
Color

Adjust image size.


Image Size

Change the screen size according to the image


Zoom Mode
aspect ratio.
Fill the Image left and right on the screen.
Horizontal Pan

Fill the Image up and down on the screen.


Vertical Pan
Option
On/Off auto adjust.
Auto Mode

On/Off LED function.


LED Mode

Moves the OSD left and right on the screen.


H-Position

Moves the OSD up and down on the screen.


V-Position

Rotations the OSD.


Rotation

OSD Adjusts OSD display time setting.


Time Out

Choose language of the display on the screen.


Language

Resets the highlighted control menu to the factory


All Reset
setting.
Lock OSD function.
Key Lock

Shows information of Firmware, Source and


Information
Utility Resolution.

Setting Value when the image to occur overlapped.


Overlapped

Page 28 Chapter 2 - Installation Procedure


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

2.3.4 Lock Mode Explain


MDC1900-1LG system default is Off mode.
LOCK
• Off: Function keys are non-lock, press "Menu" key to start the OSD menu and you can
adjustment any functions.
• Mode 1: All function keys are locked.
• Mode 2: All function keys are locked unless brightness control. Press "Menu" key to start the
brightness control menu.
• Operation step as follows:
1.) Press "Menu" key to start OSD freature.
2.) Select Setup Menu and press "Enter".

SetUp
M

All Informa
ti
Lock

2 – INSTALLATION
Overlapp

PROCEDURE
3.) Press "<" or ">" to select Lock Mode and press "Enter".

Setup
M

All Informa
Lock ti
Overlapp

4.) Press "<" or ">" to select Lock Mode and press "Enter" will save the setting value
automatically.

Chapter 2 - Installation Procedure Page 29


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION
5.) When you press any buttons on the front of the display that will shows message "OSD
locked" after setting Lock Mode complete and exit OSD feature.

Unlock
Press left key "<" until display shows the message "Key unlocked", lock function will be remove.

Note: When you in Mode 1 or Mode 2 and unlock after 15 minutes not adjustment any function, OSD
function will be lock automatically. Only setting in "Off" mode doesn't have this appearance.

2.3.5 Hot Key Controls


It can choose the best operation mode to offer to users. This product has offered the following
adjustment functions. The setting mode is not in OSD controls and single-click the hot key, can
start hot key function, as follows:
1.) Input Source Selection
Press "ENTER" button to select the input source.

VGA DVI-A DVI-D

VGA:Acquire analog signal from the D-sub connector.


DVI-A:Acquire analog signal from the DVI-I connector.
DVI-D:Acquire digital signal from the DVI-I connector.
2.) Mode item Selection
Press "<" (left) button, you can selecet color on the front of the screen of display.

User Mode DICOM Mode CL Mode

LB Mode BL Mode
• User Mode: User identify the standard display operation.
• DICOM Mode: System set the DICOM standard operation.
• CL Mode: To imitate the display output color temperature of about 6500k.
• BL Mode: To imitate the display output color temperature of about 9300k.
• LB Mode: To imitate the operation for whitelight lampbox.

Page 30 Chapter 2 - Installation Procedure


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION
3.) Gamma item Selection
Press" >" (right) button, select Gamma value.

Native Gamma 1.8 Gamma 2.0

User DICOM Gamma 2.2

• Native: Default.
• Gamma 1.8: The display state is 1.8 for gamma value.
• Gamma 2.0: The display state is 2.0 for gamma value.
• Gamma 2.2: The display state is 2.2 for gamma value.
• DICOM: The display state is standard for DICOM.
• User: The display state is by oneself set for gamma value.

2 – INSTALLATION
PROCEDURE
2.3.6 Contrast and Brightness Minor Adjustment
1.) Select Service → Image Quality → Install SMPTE image (To install the SMPTE image on
the system.)
2.) Click on ImageWorks

3.) Select "SMPTE" image in the Examination list.


4.) Click on Viewer to display the SMPTE pattern.
5.) Enlarge the SMPTE image to full screen display, using Display → Routine Display → Zoom.
If necessary, drag the Zoom slider to display the pattern to the full screen.

Chapter 2 - Installation Procedure Page 31


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 2 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

6.) Adjust Contrast and Brightness to the level an user desires so that a slight (not clear)
distinction should be made between 0% and 5% and between 95% and 100%.

5% 95%
0% 100%

7.) Also check if the patterns are properly displayed.

Section 3.0
Function Check
1.) Perform Power On Self Test:
a.) Switch ON the main switch of the OC.
The test progress information is displayed on the monitor.
b.) Verify that the system starts up normally.
2.) Perform the normal test scannings and check that the images are normal.

Section 4.0
Disposal

WARNING This product consists of devices that may contain mercury, which must be recycled
or disposed of in accordance with local, state, or country laws. (Within this system,
the backlight lamps in the monitor display contain mercury.)

Page 32 Chapter 2 - Installation Procedure


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 1 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

Chapter 3
Finish Installation

Section 1.0
Attach Rating Plate
1.) Attach the provided rating plate to the following location of OC.
Figure 3-1 Rating Plate for Big OC

OC Rear Side

3 – FINISH INSTALLATION
Label area Rating plate

Figure 3-2 Rating Plate for Small OC


Rear View Option Rating Plate

Rating Plate

OC Rating Plate

Chapter 3 - Finish Installation Page 33


GE HEALTHCARE
DIRECTION 5178234-100, REVISION 1 CHILIN 19" COLOR LCD MONITOR OPTION INSTALLATION

Section 2.0
Return Installation Card
1.) Complete and verify the site-specific information on the Red Product Locator Installation Card.
2.) Send the Product Locator Card to the appropriate address provided belowl:
- Address for GEMS-AM sites:
Send to the address printed on the Product Locator Card.
- Address for GEMS-E sites:
Send to the address Printed on the Product Locator Card.
- Address for GEMS-A sites:
Send to the local PLS or Service Administrator.

Page 34 Chapter 3 - Finish Installation


CT
3000 N. Grandview Blvd.,
Waukesha, WI 53188 U.S.A.

www.gehealthcare.com

Imagination at work

You might also like