You are on page 1of 6

Communication Module

Residential

AD-xU/G Versions 4.1 and 4.2

E35C
Technical Data

E35C AD-xU/G Version 4.1 and 4.2 communication modules provide TCP/IP communication
over a 2G/3G mobile network between E350 meters and a central system.
Up to four multi energy devices can be connected via M-Bus.

Date: 31.10.2017
File name: D000054260 E35C AD-xU-G Versions 4.1 and 4.2 Technical Data en b.docx

© Landis+Gyr D000054260 en b
2/6

Revision history
Version Date Comments
a 26.06.2015 First edition
b 31.10.2017 Validity expanded to include version 4.2 (firmware version V54.10.10).

Although the information contained within this document are presented in good faith and believed to be correct, Landis+Gyr (including its
affiliates, agents and employees) disclaim any and all liability for any errors, inaccuracies or incompleteness relating to the product.
Landis+Gyr makes no warranty, representation or guarantee regarding the performance, quality, durability or suitability of the products for
any particular purpose. To the fullest extent permitted by law Landis+Gyr disclaims (1) any and all liability arising out of the use of the
product, (2) any and all liability, including, but without limitation to, special, consequential and indirect damages and losses, and (3) any and
all implied warranties, including, but without limitation to, fitness for purpose and merchantability.
The information contained in this document is strictly confidential and is intended for the addressee only. The unauthorised use, disclosure,
copying, alteration or distribution of this document or the contents thereof is strictly prohibited and may be unlawful.
All product information are subject to change without notice.

© Landis+Gyr D000054260 en b – E35C – AD-xU/G Versions 4.1 and 4.2 – Technical Data
3/6

E35C AD-xU/G Versions 4.1 and 4.2 – Technical Data


2G/3G module Voltage
Functions Nominal voltage 3*230/380 V
Extended metering functions acc. to IDIS pack II: Voltage range 80% - 115%
- Multi energy capability Frequency 50 Hz and 60 Hz ±3 Hz
- M-Bus master to connect up to 4 multi energy
devices Backup time
- Hourly, daily and monthly profiles for electricity With super cap > 7 days
values
Charging time for max. backup 24 hours
- Hourly and daily profiles of multi energy devices
- Internal clock, synchronised remotely
- Remotely configurable tariff/rate control Fitting
- Disconnector control Directly in E350 meter series 1 and 2 family,
sealable.
2G/3G interface:
- UMTS/HSDPA: Dual band, 900/2100MHz
Environmental influences
- GSM/GPRS/EDGE: Dual band, 900/1800 MHz
- SIM-card holder for normal size SIM card Temperature range
- IPv4 protocol Operation * –40 to +70 °C
- TCP protocol Storage –40 to +85 °C
- Dynamic and fixed IP address (depending on SIM * Communication over 2G/3G network only possible at
card assignment) temperatures > -30 °C
Max. temperature with super cap option (see section type
Optical communication Interface for local designation) +55 °C
parameterisation and reading
Wired M-Bus interface: Ingress protection to IEC 60529 IP 53
- Interface to multi energy devices for readout,
clock synchronisation, disconnector control Humidity range
Wireless M-Bus interface: Operation 0 - 95%
- 868 MHz ISM-Band link to multi energy devices Storage 0 - 95%
for readout, clock synchronisation, disconnector
control Pollution degree 2
Inputs and outputs:
- One rate control input Max. operating altitude 2000 m
- One digital input set as S0, alert or local
disconnector command Electromagnetic compatibility
- First output set as control output or S0 signal Electrostatic discharges to IEC 61000-4-2
- Second control output
Contact discharge 8 kV

GSM/GPRS
Electromagnetic RF fields to IEC 61000-4-3
Dual band 900/1800 MHz
80 MHz to 2 GHz & 1.4 to 2.7 GHz 10 and 30 V/m
GPRS Class 12 multi-slot
GPRS Class B mobile station
R&TTE directive 1999/5/EC
CSD up to 9.6 kbit/s
Spectrum for
- Short Range Devices (SRD) 25…1000 MHz,
UMTS Low Power Radio (LPR) 868 MHz EN 300220
Dual band 900/2100 MHz - GSM 3G PP TS 51.010.1
CSD up to 14.4 kbit/s - UMTS EN 301908-1
UMTS (HSPA) up to 384 kbit/s EMC for
- Short Range Devices (SRD) 25…1000 MHz,
Power consumption (no load at wired M-Bus) Low Power Radio (LPR) 868 MHz EN 301489-1/-3
Typical w/o communication (1ph) 1.5 W / 3.2 VA - GSM EN 301489-1/-7
Max w/o communication (1 ph) 2.1 W / 4.2 VA - UMTS EN 301489-1/-24
Typical with communication (3ph) 1.8 W / 3.9 VA Safety EN 61010-1
Max with communication (3 ph) 2.6 W / 5.3 VA

D000054260 en b – E35C – AD-xU/G Versions 4.1 and 4.2 – Technical Data © Landis+Gyr
4/6

Electromagnetic compatibility (cont.) M-Bus antenna


Radio interference suppression according to Antenna connector MCX (f), impedance 50 Ω
IEC/CISPR 22 class B
Rate control input (2 rates)
Control voltage Ut 230 V AC
Fast transient burst test to IEC 61000-4-4
Permissible range 80 - 115% Ut
Current and voltage circuits not under load 4 kV
Current consumption < 2 mA ohmic at 230 V
Current and voltage circuits under load
According to IEC 62053-21 2 kV
Auxiliary circuits > 40 V 1 kV Digital input
S0 or alert input according to IEC 62053-31 or
DIN 43864 or local disconnector command
Fast transient surge test to IEC 61000-4-5
Voltage max. 40 V
Current and voltage circuits 4 kV
Auxiliary circuits > 40 V 1 kV
First and second control output
Voltage 12…240 V AC/DC
Insulation strength
Current max. 100 mA
Overvoltage category III acc. to IEC 61010-1
Insulation resist. to module 4 kV AC/50 Hz, 1 min

Insulation strength 4 kV at 50 Hz during 1 min. Wiring terminals


Control outputs screwless spring-type terminals
Impulse voltage 1.2/50 μs to IEC 62052-11 Rate control input screwless spring-type terminals
Current and voltage circuits 8 kV M-Bus and digital input screw terminals
recommended cable double insulated as
Protection class to IEC 6050-131 2 G51 1x2x0.6 gu

Inputs and outputs Connection to meter


2G/3G antenna 6-pin connector at rear of module for data
Antenna connector MCX (f), impedance 50 Ω 2 - 4 spring contacts for (1) 3 x 230 V supply
Antenna stub antenna (P000266130)
supplied with the module Weight and dimensions
Weight max. 223 g
Optical communication interface
Type serial, bi-directional interface Width/Height/Depth 90/165/45 mm
Protocol according to IEC 62056-21
Material
M-Bus interface
Case polycarbonate
"Point to point" or "multi-point" bus system.
Flammability class UL94 V-0
Standard EN 13757
RoHS II compliant
Max. transmission rate 2400 bit/s
Max. M-Bus unit loads (1 unit load = 1.5 mA) 16
Max. wiring length ≤ 50 m
Transmission from master:
MARK: H = SPACE voltage + ≥ 10 V but < 42 V
SPACE: L ≥ 12 V
Transmission from slave:
MARK: L = 0 mA to 1.5 mA
SPACE: H = (11 mA to 20 mA + MARK current)

Wireless M-Bus interface


Standard EN 13757-4
Conformity EN 300220
Frequency 868.3 MHz, 868.95 MHz (ISM Band)
Output power max.14 dBm EIRP with dipole antenna
Modulation FSK

© Landis+Gyr D000054260 en b – E35C – AD-xU/G Versions 4.1 and 4.2 – Technical Data
5/6

Type designation
AD – F U 1 1 D 1 5 B .

Type of module
C Internal module ZCF (single-phase version)
F Internal module ZMF (three-phase plus neutral version)
G Internal module ZFF (three-phase no neutral version)

Communication medium
G 2G (only) mobile network
U 2G/3G mobile network

Rate control
1 1 control input (2 rates) / Time of use (TOU)

Digital inputs
1 1 digital input (S0 pulse input, alarm input or local disconnector command)

Communication gateway
D Wired M-Bus only
G Wired and wireless M-Bus

Disconnector control
1 Disconnector control (for E350 S2 only)

Outputs
5 2 output contacts (1x S0 and 1x control, or 2x control,100 mA/230 VAC)

Extended functions
0 None (default)
B Super cap option for power cut alarms

D000054260 en b – E35C – AD-xU/G Versions 4.1 and 4.2 – Technical Data © Landis+Gyr
Contact:
Landis+Gyr AG
Theilerstrasse 1
CH-6301 Zug
Switzerland
Phone: +41 41 935 6000
www.landisgyr.com

You might also like