Professional Documents
Culture Documents
00 m Staging - M30
Design of roof slab - 100 mm thick
Using 10 mm dia. RTS
Effective depth = 100 - 45 - 5 = 50 mm
Roof slab projection = 0 mm
Diameter of roof slab = 9.0 m
According to IS 3370 - ( Part 2 ) : 2009 - Clause 5.3
If the tank is supported on walls or other similar supports, the floor slab shall be designed for bending moments due to
Max. panel size = Diameter of inscribed circle
= 4.0 m
Load calculation
Live load = = 1.5 KN / m2
Self weight = 0.1 x 25 = 2.5 KN / m2
Total 4 KN / m2
3
Provide 10 mm RTS
Spacing = 1000 x 78.5398 = 214.4 say 200 mm c/c 392.699 mm2
366.37 Bothways
H2 Max. -ve B.M. Co - eff. Max. +ve B.M. Co - eff. Hoof tension Co. eff.
Dt at 1H at 0.6H at 0.5H
14 - 0.009 + 0.0008 + 0.539
12 - 0.0104 + 0.0013 + 0.543
12.86 - 0.0098 + 0.00108 + 0.54127
( 2 x 1000 )
= 139.71 mm
4
Thickness of side wall provided is 150 mm Hence safe
Using 10 mm dia. RTS
Effective depth = 150 - 45 - 5 = 100 mm
Vertical reinforcement for
Max. -ve B.M. = 6506.6 x 1000 = 581.98885 mm2
130 x 0.86 x 100