You are on page 1of 1

Shoring Top Level

0.0m BGL

1st Layer Anchor Level


-1.50m BGL

40°
Soil Side Additional Anchor Level
h -4.50m BGL
n gt
Le
ee
Fr Steel Plate

40°
(460x460x18mm)

Steel Wailer Beam Excavation Side


(2UPN 260 grade S355)
Ground Anchor
2nd Layer Anchor Level
h -7.50m BGL
n gt
Le
ee
Fr

40°
h
n gt Ground Anchor
h
Le ngt
ond Le
B e
F re

Ground Anchor
3rd Layer Anchor Level
-12.5m BGL
h
n gt
Le
nd
40°

B o

gth
n
t h Le
ng e e
Le Fr
nd
Bo Ground Anchor Excavation Level
-16.0m BGL

NOTES:
gth
n 1. All dimensions are in meter unless specified otherwise.
Le
0.8m

nd 2. The provided layout is indicative only and can be modified in due course
Bo
subject to the approval of Main Contractor / Consultant.
800mm Thick
3. C28 / 35 grade (non-durable) concrete for D-wall.
D-Wall
4. C30 grade grout for ground anchors.
5. BS 500B black deformed steel for D-wall.
6. The above rebar details are provided for single bite (2.8m length) panel.
7. The rebar quantity shall be increased proportionality for multi
bite panels (longer than 2.8m)

Toe Level
SHUQAIQ - 1 SWRO PLANT PROJECT
-24.0m BGL
Drawing Title: Shoring Section

SHORING SECTION Reference No.: -------------

- SCALE N.T.S. Status: Design Drawing Drawn By: AA

Rev: R-0 Checked By: ZS

Sheet Size: A3 Apprvd By: GD

Scale: N.T.S. Date: 07-09-2021

You might also like