Professional Documents
Culture Documents
1 MOTOR DATA
2 Purchaser Requirements Supplier Data
3 Standard Site Standard O NA
4 1.Motor Tag Number
5 2.Driven Equipment
6 3.Nameplate Horsepower
7 4.Utilization Voltage 460 VAC, 3 Ph
8 5.Synchronous Speed, rpm
9 6.Full Load Amps (FLA)
10 7.Locked Rotor Amps (LRA)
11 8.NEMA Design B
12 9.Temperature Rise, C 80
13 10. Insulation F
14 11.Class Service 1.15
15 12.Factor Distance
16 From VFD to Motor
17 SYSTEM FEATURES
18 Purchaser Requirements Supplier Data
19 Standard Site Standard O NA
20 13. Adjust. 1-30
21 14.Accel Rate, Hz/sec Adjust 1-30
22 15.Decel Rate, Hz/sec Critical 3
23 16.Frequency Lockout Slip Required
24 17.Compensation Automatic Required
25 18.Torque Boost Carrier 2 to 8
26 19.Freq Range, kHz Adjustable Required
27 Min/Max Speed
28 PERFORMANCE DATA
29 Purchaser Requirements Supplier Data
30 Standard Site Standard O NA
31 20. Acceptable None
32 21.Line Notching Adjustable 3-12
33 22.V/Hz Range V/Hz 2
34 23.Regulation, +% Output 0-400
35 25.Frequency Range, Hz Frequency 0.5
36 26.Stability, +% Frequency 0.01
37 27.Resolution, Hz Total Refer to Spec
38 28.Harmonic Distortion Highest Refer to Spec
39 29.Single Harmonic Eff at Full 95 Minimum
40 30.Load/Full Speed, % Power 0.95 or Better
41 31.Factor Total
42 System MTBF, hr
43
44
45
46
1 CUSTOMER INPUTS
2 Purchaser Requirements Supplier Data
3 Standard Site Standard O NA
4 1.Start Forward Dry Contact Input
5 2.Start Reverse Dry Contact Input
6 3.Stop Dry Contact Input
7 4.Speed Control Signal, mA 4-20
8 5.Fault Reset Not Required
9 6.Run Indication Req (From C SPDT)
10 7.Common Fault Alarm Req (From C SPDT)
11 8.Common Failure Alarm Req (From C SPDT)
12 9.Output Speed/Frequency, mA Required (4-20)
13 10. Output Not Required
14 Current PHYSICAL DATA
15 Purchaser Requirements Supplier Data
16 Standard Site Standard O NA
17 11. Outline
18 12.Dimens, H x W x D, in. Weight, lb
19 13. Heat
20 14.Dissipation, Btu NEMA 1
21 15.Rating of Enclosure Mounting Wall Mount
22 16.Configuration Cable
23 Entry (Top or Bottom) OPTIONAL METERING (SPECIFY ANALOG OR DIGITAL)
24 Purchaser Requirements Supplier Data
25 Standard Site Standard O NA
26 17. 3 PH Input
27 Current,
of Motor 0-150%
FLA
28 18. 3 PH Input
29 19.Volt, 0-600 VAC 3 PH
30 Output
of MotorCurrent,
FLA 0-150%
31 20. kW Meter, 1
32 0-150%
kW Rating of Motor
33 21. kW-hr
34 22.Meter Elapsed
35 Time Meter OTHER OPTIONS
36 Purchaser Requirements Supplier Data
37 Standard Site Standard O NA
38 23. Input Circ Circuit Breaker
39 24.Break or Fused Discon Full Not Required
40 25.Voltage Bypass PID Not Required
41 27.Controller P/I Not Required
42 Transducer for Signal
Speed Control Pneumatic
43 28. Space Not Required
44 29.Heaters Start-up
45 30.Assistance Serial
46 31.Comm (RS 232 etc. Integral Not Required
A/C