l Extensive Mimic display with Electronic Controller

l Energy saving purge economiser


l Stainless Steel Filters Catridges
l Fabrication Code : IS 2825
l Dewpoint better than -40o C
Optional :
Compressed Air Dryers (Heatless)
l Fabrication Code : ASME SEC VIII DIV I
l Dewpoint based changeover DP Series
Highlights Principle of Operation
Purge Economiser : By setting a switch in the controller at a Pre-filteration : The moisture laden compressed air passes through
percentage of maximum flow, the controller will close the purge the pre filter. Here moisture load is reduced through coalescence.
Condensation is removed through the drain valve ADV1. At the oil
valve when sufficient purge air has been used. This reduces
filter, oil vapours are removed completely and a small level of water
purge loss according to air usage. The purge loss, which is 14% condensation is purged through the valve ADV2.
normally reduces to as low as 5.6%.
Drying : (Please refer figure) The Towers are filled with Activated
Alumina as desiccant (Molecular sieve available as option). When
No pressure spike : During changeovers, it ensures long
air passes through Tower 1 which consists of “DRY” Desiccant, it
desiccant life. gets completely dried, and passes through the check valve and
the after filter. At the after filter, Desiccant fines are removed.
Selection Example Therefore, dry compressed air passes out at the outlet.
Requirement :
Regeneration : (Please refer figure) Regeneration takes place
Flow Volume : 480 m3/hour in 2 stages a) De-pressurisation b) By passing Dry air. Tower II
Working Pressure : 7 Kg / cm2 consists of fully moist desiccant in pressure. This is suddenly
De-pressurised by opening the purge valve. Water molecules
Inlet air Temperature : 45oc seep out of the desiccant and appear on the surface. “Super
Referring the Graphs : Factor (T) = 0.9 Dry” purge air passes through the Regeneration “Nozzle” and
Factor (P) = 1.0 the desiccant bed thereby completely carries away the water
molecules. Tower II gets regenerated and is ready for the next
Dryer capacity required :
drying cycle after the re-pressurisation.
Flow volume 480
= 533.3 m3/hour
Factor (T) x Factor (P) 0.9 x 1.0

Choose the nearest higher model i.e, Model DP 768 M

Specification
Inlet Dimensions (mm)
Item End Weight
Model Flow
Code Connection Kg
cfm Height Width Depth

DP-768 M PD020 400 2" NB 1810 1200 1300 850 Inlet Temperature Correction Factor
1.2
DP-768 PD019 458 2" NB 1810 1200 1300 850
1.1
Factor (T)

1.0
DP-960M PD022 500 2" NB 1830 1300 1300 950
0.9
DP-960 PD021 572 2" NB 1830 1300 1300 950 0.8

0.7
DP-1440M PD055 750 3" NB 1975 1500 1500 1265 30 35 40 45 50 60
Inlet Temp oc

DP-1440 PD023 860 3" NB 1975 1500 1500 1265 Inlet Pressure Correction Factor
2.25
DP-1920M PD026 1000 3" NB 2100 1500 1500 1575 2
1.75
Factor (P)

DP-1920 PD025 1144 3" NB 2100 1500 1500 1575 1.35

l Operating voltage - 230 V AC 50 Hz 1 Ph. 1


l For any other capacity contact factory. 0.7
4 7 10 13 15 16
l Specifications are subject to change without notification.
Inlet Pr. Kg / cm2

Our Other Range of Products


lTimer based Auto Drain Valve l Level Sensing Auto
Drain Valve l Desiccant Dryer (Heated) l Refrigeration Dryers
l Moisture Separator l Submicron Filter
l Oil Water Separator

Trident Pneumatics Pvt Ltd


5/232, K.N.G. Pudur Road, Coimbatore - 641 108, India. Ph : +91-422-2400492, 2401373 Fax : +91-422-2401376
e-mail : sales@tridentpneumatics.com Website : www.tridentpneumatics.com
02 / 17

Sales & Ahmedabad Bangalore Chennai Delhi Hyderabad & Kolkatta Mumbai & Pune
Service Outlets 98673 67726 98450 93322 97894 80564 93113 10726 98854 45321 98673 67726

You might also like