You are on page 1of 1

FIELD PERMEABILITY TEST(Vertical)

BS-5930 (1981)
Constant Head Permeability Test Site: Head Khanki Barrage Location:
Depth below top of casing: Job No. Borehole: BH - Bhabr
(a) Bottom of borehole: 18 ft Date: 23-05-08 Test No: 03
(b) Bottom of casing: 18 ft Groun level: Crew/Operator: Mohsin
(c) Top of filter material: - Weather: Sunny Tested by: Adnan / Safdar
(d) Initial ground water level: 10 ft External diameter of casing: 0.2403 ft
Height of casing above surface: 1.87 ft Length of filter: - ft
Elevation of casing: cm Type of soil: Clayey Silt

Clock Time Elasped Time Initial Reading Final Reading Flow (cm3)
8:32:00AM 1 (1) 1000 999 1
8:33 1 (2) 999 997 2
8:34 1 (3) 997 995 2
8:35 1 (4) 995 992 3
8:36 1 (5) 992 990 2
8:38 2 (7) 990 987 3
8:40 2 (9) 987 982 5
8:42 2 (11) 982 978 4
8:44 2 (13) 978 975 3
8:46 2 (15) 975 970 5
8:51 5 (20) 970 961 9
8:56 5 (25) 961 950 11
9:01 5 (30) 950 940 10
9:11 10 (40) 940 920 20
9:21 10 (50) 920 900 20

Total Elapsed Time (Min) 50 (3000) Total Flow ( cm3 ) 100

q= (Total Flow) / (Elapsed Time) 3.33 x 10-2 cm3/sec


F= 2.75 x 7.325 = 20.143 cm
Hc= ( Total Head in cm ) 361.18 cm
K= q/ F * Hc = 4.56 x 10 cm/sec
-6