You are on page 1of 4

DAILY REPORT

DATE MACHINE PROBLEM


BOILER NOT FIRING
2-Mar-20 HAND PUCHING V BELT WORN OUT
PERFECTA NEW JOGGER PUSH -OUT ROLLER NOT WORKING
CORE CUTTING
3-Mar-20 PNEUMATIC CYLINDER PISTON CAME OUT
HSING WEI GENERAL MAINTENANCE
CERUTTI, BOILER HSING WEI GENERAL MAINTENANCE

4-Mar-20 NILPETER 5,6,7 UNIT UV NOT WORKING

HEIDELBERG CD 74 PAPER NOT RUNNING, FEEDER PROBLEM


APPOLO SHEETER Belt path roller bearing end worn out
5-Mar-20
CERRUTI 2 ND UNIT THOMAS COUPLING

CERRUTI 2 ND UNIT THOMAS COUPLING


6-Mar-20
CERUTTI 3 RD UNIT THOMAS COUPLING

CERUTTI 3 RD UNIT THOMAS COUPLING

7-Mar-20
TEMPRATURE IS NOT REACHED TO SET
BOILER POINT STILL IT SHOWING TEMPRATURE IS
REACHED
APPOLO SHEETER Belt path roller bearing end worn out
8-Mar-20
CERUTTI
8TH UNIT THOMAS COUPLING
PERFECTA CUTTING
BACK GAUGE IS CROSSED
9-Mar-20
CERUUTI
7TH UNIT THOMAS COUPLING
CERUUTI
10-Mar-20 6TH UNIT THOMAS COUPLING
COMPRESSOR Leak testing
CERUUTI
11-Mar-20 4TH UNIT THOMAS COUPLING
NILPETER CYLINDER LOCKING SHAFT NOT WORKING
12-Mar-20 BUSCH PUNCHING Machine not running in auto mode
PVC EXTRUSION Dia heating is not getting on
13-Mar-20 NILPETR Water leakage in rotary union
14-Mar-20 NILPETR unit No 7 UV lamp not working
15-Mar-20 blummer pm done
16-Mar-20 battery operated trolly pm done
17-Mar-20 battery operated trolly pm done
boiler NOT FIRING
18-Mar-20
nilpeter 6 unit 7 unit Uv problem
19-Mar-20 nilpeter 6 unit 7 unit Uv problem
20-Mar-20 nilpeter 7 unit UV problem
21-Mar-20 appollo sheeter preventive maintenance
23-Mar-20 cerutti 7th unit main motor replaced

23 mar 2020 to all machine from pre press shifted to


pre press machine shifting work
31 march 2020 mazenine floor
DAILY REPORT
WORK DESCRIPTION PART REPLACEMENT REMARK
cleaning of fillters done None
Replaced new V belt V belt No.A 2314
faulty sensor replaed PEPPERL+FUCHS NBB2-12 GM50-E2

dismantaled cylinder, refixed shaft None

clean all filters None


All stainers, filters cleaning done None
5 & 6th Unit drive board replaced,7 unit
work is pending
frontlay sensor faulty, bypass sensor None
roller assembly removed send it to work in process
workshop for repairing
Removed coupling for replacemrnt of spring
work in process
plate and bearing
Replaced spring plate and bearing of
thomas coupling
Removed coupling for replacemrnt of spring
plate and bearing
Replaced spring plate and bearing of
thomas coupling

Interchages thermocouple,parameter is
distrube reset parameter

Assembled fabricated roller


Replaced spring plate and bearing of
thomas coupling

removed cocking assembly,set encodder

Replaced spring plate and bearing of


thomas coupling
Replaced spring plate and bearing of
thomas coupling
cross verify with report
Replaced spring plate and bearing of
thomas coupling
Assembly broken, repairing is done
limit switch is faulty ,replaced switch
temprature controll is faulty,replaced
attented, send enquiry to OEM
checked drive board and valve problem,
asked for spare

You might also like