Bhopal Metro Rail Project

Package BH-06

Item Traction and Power


Item Description Depot Contractor(s)
No. Supply Contractor
workstations and LCD screen
for power SCADA in OCC/BCC
theatre.

c. Shall extend SCADA


connectivity to E&M c. Shall provide necessary
panels (MDB Only) as potential free contacts for
required. SCADA connection.

11. Installation of a. Shall provide detailed a. Shall provide the supporting


stinger system, in interface drawings structure for stinger
inspection bay, including the requirement suspension /bracket assembly
repair bay, of mounting plates on on the brackets and drop arms
stabling shed, columns, drop arms fixed fixed on trusses as per
interior cleaning to the trusses, support for drawings.
plant and termination arrangement
b. Shall provide terminals for
emergency on beams /slabs etc.
control power supply (ac
equipment
b. Shall supply and install Power) to Stinger.
building
bracket assemblies with
fastening arrangement on
columns and drop arms. c. Shall interface and allow
installation of cable support
c. Shall supply and install
infrastructure
cable support
infrastructure (brackets,
trays, etc.) for all control
and power cables.

12. Emergency Trip Design:


System (ETS)
Shall inform about the
Installation
requirement of ETS.

Construction:
Construction:
a. Shall coordinate for
a. Shall provide niche in walls or
locations of ETS at
support structure to
stations.
accommodate ETS equipment
and emergency telephone.

b. Shall coordinate and provide


emergency 230V LT supply

Attachment – 8 to Corrigendum – 2, Date: 10.11.2021 Page 38 of 80