You are on page 1of 8

ECP Combination (Ultimate Case )

Definitions: -

D = Dead Load
L.L = Live Load
W = Wind Load
S = Earthquake Load

M.E = Main Equation from CODE


α = 1 IN CASE OF TANKS, Libraries, stores, and
Buses Garage
0.5 IN CASE OF Facilities, Public buildings, Schools,
Hospitals, Theaters, and cars Garage
0.25 IN CASE OF Residential buildings
- Equations:

U1 = 0.9 D

U2 = 0.9 D + 1.3 WX U3 = 0.9 D - 1.3 WX

M.E1 = 0.9 D + 1.3 W

U4 = 0.9 D + 1.3 WY U5 = 0.9 D - 1.3 WY


U6 = 1.12 D + 1.28 L.L + 1.28 WX

U7 = 1.12 D + 1.28 L.L - 1.28 WX

M.E2 = 1.12 D + 1.28 L.L + 1.28


W

U9 = 1.12 D + 1.28 L.L - 1.28 WY

U8 = 1.12 D + 1.28 L.L + 1.28 WY


U10 = 0.9 D + SPEC X

U11 = 0.9 D - SPEC X

M.E3 = 0.9 D + S

U13 = 0.9 D - SPEC Y

U12 = 0.9 D + SPEC Y


U14 = 1.12 D + α L.L + SPEC X

U15 = 1.12 D + α L.L - SPEC X

M.E4 = 1.12 D + α L.L + S

U17 = 1.12 D + α L.L - SPEC Y

U16 = 1.12 D + α L.L + SPEC Y


U18= 0.9 D
+ SPEC X +
0.3 SPEC Y
U25 = 0.9 D U19 = 0.9 D
- SPEC Y- + SPEC X -
0.3 SPEC X 0.3 SPEC Y

U24 = 0.9 D M.E5 = 0.9 D U20 = 0.9 D


- SPEC Y + - SPEC X +
0.3 SPEC X + S1 +0.3 S2 0.3 SPEC Y

U23 = 0.9 D U21 = 0.9 D


+ SPEC Y - - SPEC X -
0.3 SPEC X 0.3 SPEC Y
U22= 0.9 D
+ SPEC Y
+0.3 SPEC X
U26 = 1.12 D
+ α L.L +
U33 = 1.12 D SPEC X + 0.3
+ α L.L - SPEC Y
SPEC Y- 0.3 U27 = 1.12 D
SPEC X + α L.L + SPEC
X - 0.3 SPEC Y

U32 = 1.12 D U28= 1.12 D


+ α L.L - SPEC M.E6 = 1.12 D +α + α L.L -
Y + 0.3 SPEC L.L + S1 +0.3 S2 SPEC X + 0.3
X SPEC Y

U31= 1.12 D U29 = 1.12 D


+ α L.L + SPEC + α L.L - SPEC
Y - 0.3 SPEC X X - 0.3 SPEC Y
U30 = 1.12 D +
α L.L + SPECY
+0.3 SPEC X