1.6KVA 12V MultiPlus 230 Volt System Example 4 PIN VE Bus BMS Lithium Orion TR
1.6KVA 12V MultiPlus 230 Volt System Example 4 PIN VE Bus BMS Lithium Orion TR
Absorbtion
GND Power I 360W (30A)
Float
Bulk
color control on/off
BATTERY PV INPUT OUTPUT
BMS ON/OFF
+ - - + L H + - - +
ETHERNET
VE-direct-1
VE-direct-2
VE BUS-1
BMS POWER+
VE-direct
BMS LOAD DISCONNECT
BMS CHARGE DISCONNECT
VRM Remote on/off and engine
WORLD
FROM MULTI
detection override is active
MAIN SWITCH-1
WIRE LINK
ORION H-CONTACT
OFF FROM MPPT BETWEEN L & H
M8 CIRCULAR CONNECTORS
BTV CABLE
BTV CABLE
m ON VE-Bus to BMS
MAIN DC
Li-DISTRIBUTION DISTRIBUTION
POSITIVE
BUSBAR POSITIVE
CYRIX Li BUSBAR MAIN FUSE ORION INPUT
CHARGE-120
MEGA
Load+
Starter Battery
60 AMPERE
285060F
KEEP POSITIVE BATTERY CABLES MAIN FUSES Charger Starter Battery 3A FUSE
MEGA OFF
ALL AT THE SAME LENGTH ! ANL
xxxA Load+
175A
MEGA
xxxA Load+ AGM 12-100 m ON
40 AMPERE
IGNITION
285040F
MAIN SWITCH-2 50 FUSE
BMS 0.5A MPPT+ xx AMP.
BMV 100mA
OFF victron energy 30 FROM STARTER+(30) 30 15
BLUE POWER
CCGX 1A
60 AMPERE
285060F
FUSES m ON STARTER Charge light
Orion+ MOTOR
MEGA
175A Multiplus Batt +
INTERNAL
ALTERNATOR
FUSE
victron energy
BLUE POWER
AMI
100A
BMV-712 SMART
BMV-712 SMART
BATTERY MONITOR
victron energy
CCGX POWER + BLUE POWER
multiplus
BMV POWER + MAIN V
VE-direct
12 | 1600 | 70 230V SHORE POWER
BTV CABLE SETUP SELECT
www.victronenergy.com
CONNECTION
IP21
BTV CABLE CENTRAL NEGATIVE BUSBAR ! i
D+
B- B+
victron energy
CYRIX Li- BLUE POWER
Load-
2 x Lithium
12.8V-100Ah
12.8V-100Ah
Smart LiFePO4
Smart LiFePO4
Lithium
Lithium
Load- AC DISTRIBUTION
12.8V-100Ah
victron energy
victron energy
Load-
BLUE POWER
BLUE POWER
MCB/RCD MCB/RCD
2 N 2 N
Recommended AC Out cable/breaker size MultiPlus Recommended DC cable/fuse size MultiPlus Recommended AC In cable/breaker size MultiPlus WARNING
With Power assist the MultiPlus can add 0-5 m cable length: 50SQmm AC IN must be protected by a circuit 230 VOLT IS EXTREMELY HAZARDOUS
1.3 KW to the output load when needed. Cable length stands for the total distance between breaker rated at 16A max or less. DO NOT TOUCH ANY LIVE WIRED
Together with the adjustable 16A input this the battery connections plus and minus and the This depends heavily on the size of the PARTS OF THE INSTALLATION !
all adds up to the max sum of input and MultiPlus connections ! Recommendations are connected power source.The input current WHEN IN DOUBT, ALWAYS CONSULT
output current of 16+5.6=21.6A. An Earth without other loads in the system and these also must be adjusted to fit the size of the YOUR VICTRON DEALER !
leakage with breaker or a combination should be taken into account for proper main connected power source.
MCB/RCD must be installed on the output. battery, main fuse & main switch cables ! The breaker and cable size for AC IN
Cable size must be adjusted accordingly. INTERNAL Fuse size should be 200A. should be adjusted accordingly.