Professional Documents
Culture Documents
Website: www.hiltondetection.com
E-mail: hiltondetection@gmail.com
Tel: (+852) 82088428 Fax: (+852) 82088400 Whatsapp: (+852) 6609 1239
Address: Room 2, 6/F., Lemmi Centre, 50 Hoi Yuen Road, Kwun Tong, Kowloon .
CCTV Report
Contents
1. Summary of Pipelines
2. Summary of Defects
4. Inspection Report
- Summary
- Details & Photo
5. CCTV codes
Coding Table & Grading Specification (MSCC3)
6. Drainage Plan
As built - NTS / As built
PAGE 1/1
Summary of Pipelines
Date : 01.03.21
Depths(m)
Size(mm)
Material
SCG
SPG
ICG
From To I.L. C.L.
Surface Spalling/Wear
Survey Abandoned
Joint Displaced
Encrustation
Obstruction
Meters (m)
Water Line
Open Joint
Collapsed
Deformed
Infiltration
Fractured
Item No.
Cracked
Grease
Broken
Urgent
Roots
From
Hole
Line
Silt
To
Start Manhole No. Depth Cover Level Invert Level Finish Manhole No. Depth Cover Level Invert Level
FM1.1A TFMH-B01
Use Direction Size(dia) Size Shape Material Lining Pipe Length Total Length Year Laid Cont. Page No.
F U 225 X C CI - 1.0 Z
Purpose Cat Preclean Weather Location Further Location Details (Slope Ref.)
A Z Y 1 C
000.0 ST
000.0 MH FM1.1A
000.0 WL 05
001 000.0 GP
002 001.0 GP
001.0 MH TFMH-B01
001.0 FH
Start Manhole No. Depth Cover Level Invert Level Finish Manhole No. Depth Cover Level Invert Level
FM1.1A FM1.1
Use Direction Size(dia) Size Shape Material Lining Pipe Length Total Length Year Laid Cont. Page No.
F D 225 X C VC - 0.6 Z
Purpose Cat Preclean Weather Location Further Location Details (Slope Ref.)
A Z Y 1 C
000.0 ST
000.0 MH FM1.1A
000.0 WL 05
003 000.0 GP
004 000.6 GP
000.6 MH FM1.1
000.6 FH
Start Manhole No. Depth Cover Level Invert Level Finish Manhole No. Depth Cover Level Invert Level
FM1.1 FM1.2
Use Direction Size(dia) Size Shape Material Lining Pipe Length Total Length Year Laid Cont. Page No.
F D 225 X C VC - 11.3 Z
Purpose Cat Preclean Weather Location Further Location Details (Slope Ref.)
A Z Y 1 C
000.0 ST
000.0 MH FM1.1
000.0 WL 05
005 000.0 GP
006 002.8 FL 10
007 002.8 FL 01
008 002.8 FL 04
009 002.9 FC 12 / 12
010 006.9 FL 03
011 010.5 FL 08
012 010.5 FL 11
013 010.9 FM 10 / 04
014 011.3 GP
011.3 MH FM1.2
011.3 FH
Start Manhole No. Depth Cover Level Invert Level Finish Manhole No. Depth Cover Level Invert Level
FM1.2 FMH4010784
Use Direction Size(dia) Size Shape Material Lining Pipe Length Total Length Year Laid Cont. Page No.
F D 225 X C VC - Z
Purpose Cat Preclean Weather Location Further Location Details (Slope Ref.)
A Z Y 1 C
000.0 ST
000.0 MH FM1.2
000.0 WL 10
015 000.0 GP
001.4 WL 20
016 002.1 S1 DES 30 Hard Material
017 002.1 S2 FL 12
018 002.6 F1 DES 30 Hard Material
019 002.6 F2 FL 12
020 002.6 SA Due to hard material
CCTV SURVEY
ID Pipe Length Ref. Start MH Finish MH Survey Area Function Size Grade Length Clean Remarks
1 TFMH-B01X FM1.1A TFMH-B01 - F 225 1 1.0m Y FH
2 FM1.1AX FM1.1A FM1.1 - F 225 1 0.6m Y FH
3 FM1.1X FM1.1 FM1.2 - F 225 4 11.3m Y FH
4 FM1.2X FM1.2 FMH4010784 - F 225 3 2.6m Y SA, Due to hard material
FM1.1A
0.0 MH Manhole 0
Remark : FM1.1A
0.0 WL Water Level, 5 % height/diameter 0
1.0 MH Manhole 0
Remark : TFMH-B01
FM1.1A
0.0 MH Manhole 0
Remark : FM1.1A
0.0 WL Water Level, 5 % height/diameter 0
0.6 MH Manhole 0
Remark : FM1.1
0.6 FH Finished Survey 0
FM1.1
FM1.1
0.0 MH Manhole 0
Remark : FM1.1
0.0 WL Water Level, 5 % height/diameter 0
FM1.2
0.0 MH Manhole 0
Remark : FM1.2
0.0 WL Water Level, 10 % height/diameter 0
Under normal circumstances, infiltration is broken down into 4 categories, i.e., Seeper, Dripper, Runner &
Gusher.These are service condition graded as follows
Category Grade
Seeper : 2
Dripper 2
Runner 4
Gusher 5
The 2 columns on the coding sheets headed Cont. Defects & Extra Lines are labels for each continuous defect of
1m or more in length in any drain length between node points. S1, 2, 3 (Start 1, 2, 3, etc.) and F1, 2, 3
(Finish 1, 2, 3, etc.) (See sketch below)
(Extract from MSCC 4)
Shape
Material
Enter one of the following codes for drain/sewer material. Where there is a mixture of
materials around the circumference of the drain or sewer (e.g. brick invert with a concrete
soffit) the code Z is used and details are given in the General Remarks box. Where the
drain/sewer has been relined the material recorded is the material of the original pipeline, or
enter Z if original material is unknown.
AC Asbestos cement
BL Bitumen (lining)
BR Brick
CI Cast iron
CL Cement mortar (lining)
CO Concrete
CS Concrete segments
DI Ductile iron
EP Epoxy
FC Fibre cement
FRP Fibre reinforced plastics
GI Grey cast iron
PVC Polyviyl chloride
PE Polyethylene
PP Polypropylene
PS Polyester
RC Reinforced concrete
SPC Sprayed concrete
ST Steel
VC Vitrified clay(i.e. all clayware)
PP Polypropylene
PF Pitch fibre
MAC Masonry - in regular courses
MAR Masonry - randomly coursed
X Unidentified material
XI Unidentified type of iron or steel
XP Unidentified type of plastics
Z Other(datails should be recorded in the remarks section)
Lining Material
Where the drain/sewer has been relined enter one of the codes listed under "Material" to define the lin
the drain/sewer is not lined leave the field blank.
Lining Type
Where a pipeline has been lined,record the method of the lining as follows:
The client may be able to advise, if the lining method is not known.
Codes for Service Condition Grade (SCG)
Type Code Descripion 註解 Grade
DEG Deposits Attached Grease 依附物 - 油脂 1*
DES Deposits Settled Debris / silt 依附物 - 垃圾/淤泥 1*
DE Deposits Settled Other 依附物 - 其他 1*
EL Encrustation Light 輕度凝結物 (0-5%) 2
EM Encrustation Medium 中度凝結物 (5-20%) 4
EH Encrustation Heavy 嚴重凝結物 (20%+) 5
IS Infiltration Seeping 滲漏 2
Service ID Infiltration Dripping 滴漏 2
IR Infiltration Running 湧漏 4
IG Infiltration Gushing 噴漏 5
CU Loss of Vision Camera Under Water 失去影像 0
OB Obstruction 阻塞 5
RF Roots Fine 根鬚 2
RT Roots Tap 根枝 3
RM Roots Mass 根堆 2*
1* The grade for the these defects follows the % cross section loss:
0 - 5% Grade 1 >50 - 75% Grade 4
>5 - <25% Grade 2 >75 - 100% Grade 5
25 - 50% Grade 3
2* The grade for Roots Mass follows the % of cross section loss:
0 - 5% Grade 3
>5 - <25% Grade 4
25 - 100% Grade 5