5 LIBRARY BIRR -
6 GLAZING BIRR -
2. FINISHING WORK
Provide and fix "ARMSTRONG" or equivallet
ceiling in white color and 600/ 600/ 15mm
module size, laid on 24mm exposed grid,
galvanized suspension system, comprising white
main runners and flush fitting cress tees to form a
module of 600/ 600mm. Price shall include all
accessories.
2.1 m2 550.00 -
Replaster in cement mortar and apply final coat of
gypsum plastering to all internal walls, columns
2.2 and beam surfaces. m2 1,140.00 -
Provide and apply three coats of approved plastic
2.3 paint to all gypsum plastered surfaces m2 1,140.00 -
Provide and apply cement mortar to all surfaces
2.4 of floor and wall in toilets. m2 226.00 -
Provide and fix high quality non slippery
porcelain floor tiles to toilets floor surfaces. (type
2.5 and color to be approved) m2 220.00 -
Provide and fix high quality ceramic wall tiles to
toilet wall surface as indicated in the design.
2.6 (color and pattern to approved) m2 360.00 -
Provide and fix 10cm high wooden skirting as per
2.7 the detail design. ml 160.00 -
Aluminium Partition -
P1 - 1208 x 255cm Pcs 1 -
P2 - 390 x 255cm Pcs 1 -
P3 - 808 x 255cm Pcs 1 -
P4 - 272 x 255cm Pcs 1 -
P5 - 240 x 255cm Pcs 1 -
P6 - 390 x 255cm Pcs 1 -
P7 - 90 x 255cm Pcs 4 -
P8 - 290 x 255cm Pcs 6 -
P9 - 260 x 255cm Pcs 1 -
P10 - 271 x 255cm Pcs 1 -
P11 - 259 x 255cm Pcs 1 -
P12 - 238 x 255cm Pcs 1 -
P13 - 241 x 255cm Pcs 2 -
P14 - 115 x 255cm Pcs 2 -
White powder coated aluminum frame and 6mm
thick tempered glass. Glazing shall be reflective
in green color complete with all iron manager
including mid rails for the fixed doors.
3.2
Window
W1 :- 200 x 200cm Pcs 15.00 -
W2 :- 380 x 200cm Pcs 12.00 -
4. BLOCK WORK
5.1 Provide and construct 15cm thick hollow concrete
block wall, with nominal reinforcement as per the
detail drawing in compo mortar 1:2:6 internally
and externally left for plastering m2 448.00 -
6. GLAZING
6.1 5mm thick tinted glass m2 151.20 -
7. ELECTRICAL INSTALLATION
1.0 Distribution Boards
Distribution board , breakers , switches,
accessories etc should be genuine Legrand , ABB,
Siemens or approved equivalents complying with
IEC standards. Distribution boards should be
made of sheet metal and have separate neutral and
ground busbars/phase bars.All units in the
distribution boards should should be labled to
give the reference and duty of the unit.
1.1 Surface mounted sub main distribution board
SMDB-MC-GF with lockable door, bus-bars
rating of 400A/3ph and with all its accessories
consisting of :-
1 pc m.c.c.b. of 320A/3ph
1 pc m.c.c.b. of 200A/3ph
1 pc m.c.b. of 50A/3ph
1 pc m.c.b. of 40A/3ph
2 pcs m.c.b. of 32A/3ph
1 pcs m.c.b. of 50A/1ph
2 pcs m.c.b. of 40A/1ph
and with 20% reserve space No 1 -
1.2 Flush mounted sub distribution board SDB-MED-
GF with lockable door, phase-bars rating of
50A/3ph and with all its accessories consisting of
:-
1 pc m.c.b. of 32A/3ph
6 pcs m.c.b. of 16A/1ph
7 pcs m.c.b. of 10A/1ph
and with 20% reserve space No 1 -
1.3 Surface mounted sub distribution board SDB-
OPT-GF with lockable door, bus-bars rating of
250A/3ph and with all its accessories consisting
of :-
1 pc m.c.c.b. of 200A/3ph
1 pc m.c.c.b. of 160A/3ph
10 pcs m.c.b. of 16A/1ph
12 pcs m.c.b. of 10A/1ph
and with 20% reserve space No 1 -
1.4 Flush mounted sub distribution board SDB-GYN-
GF with lockable door, phase-bars rating of
100A/3ph and with all its accessories consisting
of :-
1 pc m.c.b. of 50A/3ph
10 pcs m.c.b. of 16A/1ph
12 pcs m.c.b. of 10A/1ph
and with 20% reserve space No 1 -
MAIN BUILDING BOQ
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
1.5 Flush mounted sub distribution board SDB-LAB-
GF with lockable door, phase-bars rating of
50A/3ph and with all its accessories consisting of
:-
1 pc m.c.b. of 40A/3ph
9 pcs m.c.b. of 16A/1ph
8 pcs m.c.b. of 10A/1ph
and with 20% reserve space No 1 -
1.6 Flush mounted sub distribution board SDB-OFC-
1F with lockable door, phase-bars rating of
50A/3ph and with all its accessories consisting of
:-
1 pc m.c.b. of 32A/3ph
7 pcs m.c.b. of 16A/1ph
6 pcs m.c.b. of 10A/1ph
and with 20% reserve space No 1 -
1.7 Flush mounted sub distribution board SDB-LIB-
1F with lockable door, phase-bars rating of
50A/1ph and with all its accessories consisting of
:-
1 pc m.c.b. of 40A/1ph
3 pcs m.c.b. of 16A/1ph
3 pcs m.c.b. of 10A/1ph
and with 20% reserve space No 1 -
1.8 Flush mounted sub distribution board SDB-OFC-
2F with lockable door, phase-bars rating of
100A/1ph and with all its accessories consisting
of :-
1 pc m.c.b. of 50A/1ph
4 pcs m.c.b. of 16A/1ph
3 pcs m.c.b. of 10A/1ph
and with 20% reserve space No 1 -
1.9 Flush mounted sub distribution board SDB-LOB-
GF with lockable door, phase-bars rating of
50A/1ph and with all its accessories consisting of
:-
1 pc m.c.b. of 40A/1ph
6 pcs m.c.b. of 16A/1ph
and with 20% reserve space No 1 -
2 Light point fed through PVC insulated copper
conductors of 2x2.5 sq.mm in thermoplastic
conduit of minimum diameter 16 mm in/or under
surface including junction box with cover and
screw type insulating connectors.
No 440 -
3 Switches
Legrand SUNO or approved equivalent and for
flush installation.
3.1 One way 10A rated. No 34 -
3.2 Double pole 10A rated. No 93 -
3.3 Tripple pole 10A rated. No 1 -
3.4 Two way 10A rated. No 7 -
3.5 Two gang two way 10A rated. No 18 -
3.6 Intermediate 10A rated. No 1 -
3.7 One way dimmer 10A rated. No 2 -
4 Type of Light Fittings or Approved
Equivalents
4.1 MODUS LL136 ALDP with electronic ballast
and with 1x'TL' D 36W/830 lamps. No 13 -
MAIN BUILDING BOQ
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
4.2 MODUS LL236 ALDP with electronic ballast
and with 2x'TL' D 36W/830 lamps. No 122 -
4.3 MODUS LL418 ALDP with electronic ballast
and with 4x'TL' D 18W/830 lamps. No 73 -
4.4 MASSIVE 32081/31/10 with 1xE-27 / 18W
energy saving lamp. No 44 -
4.5 MASSIVE 34131/11/10 with 1xGX53-9W
energy saving lamp. No 30 -
4.6 MASSIVE 30802/31/10 with 1xG10Q-32W
energy saving lamp. No 90 -
4.7 MASSIVE 37655/31/10 with 2xE-27 / 23W
energy saving lamps. No 9 -
4.8 MASSIVE 30801/31/10 with 1xG10Q-22W
energy saving lamp. No 10 -
4.9 DISANO 7203 SERENA ART.NO. 720311-00
with FL2X18 INDIRECT + FL2X18 DIRECT
lamps. No 6 -
4.10 MODUS P218PCE with 2x'TL' D 18W/830
lamps. No 1 -
4.11 MASSIVE 70748/01/11 with 1xE-27 / 60W clear
standard incandescent lamp. No 3 -
4.12 RZB 931090.952 with 3xTC-D-26W energy
saving lamp. No 8 -
4.13 MODUS LL418 ALDP with electronic ballast
and with 4x'TL' D 18W/830 lamps. No 26 -
4.14 MASSIVE 16292/47/10 with 1xE-27 / 14W
energy saving lamp. No 5 -
5 Socket and Power Outlets
5.1 Flush mounted schuko socket outlets of 16A/1ph
fed through PVC conductors of 3x2.5 sq.mm in
thermoplastic conduit of minimum f 16mm
in/under surface including junction box with
cover and screw type insulating connectors.
No 84 -
5.2 Ditto as item No. 10.5.1 but for twin sockets. No 84 -
5.3 Ditto as item No. 10.5.1 but with switch and pilot
lamp indicator for water heater . No. 2
5.4 Supply power to operation theatre lamps fitting
through PVC cable of 3x2.5 Sq.mm in
thermoplastic conduit of minimum diameter m 16
25mm.
5.5 Supply power to X-Ray machine through PVC
cable of 3x95/50+1x50 Sq.mm in PVC conduit of
minimum diameter 110mm. m 16
6 Telephone and TV Points
6.1 Telephone points fed through Cat-6 UTP-100
Base TX cable in thermoplastic conduits of
minimum diameter f 19mm. Price doesn't iclude
cost of flush mounted RJ-11 sockets. No 58 -
6.2 Flush mounted mosaic RJ-11 sockets of type
legrand or approved equivalent for telephone No 58 -
6.3 network.
Supply and install TELE Terminal box of
30x20x10cm as shown in drawing and to be
located at 0.4m above finished floor level for No 3 -
flush installation.
MAIN BUILDING BOQ
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
6.4 Data points fed through Cat-6 UTP-100 Base TX
cables in surface fixed trunking.Price includes
cost of wirings. PVC trunking & R-J 45 sockets
measured elsewhere. No 58 -
6.5 Flush mounted mosaic RJ-45 sockets of type
legrand or approved equivalent for compute net No 58 -
6.6 works.
Television antenna outlet points with co-axial &
flat twin TV cables in thermoplastic conduit of
minimum diameter 19mm. No 1
6.7 Flush mounted mosaic TV/SAT sockets of type
legrand or approved equivalent for telephone No 1 -
6.8 network.
Supply, install, test and commission data and
telephone network panel for connection to 58 pcs
of RJ-45 sockets and 58 pcs of RJ-11 sockets
including patch panels, switches, feed through
panels, power supply module, fan, cable
management system, patch cords etc. to make the
system complete and fully operational.
No 1 -
7 Public Address System
7.1 Loudspeaker points fed through audio cable of
3x1.0 sq.mm in thermoplastic conduit of
minimum diameter 16mm in or under surface
including junction box with cover ,elbows, joints ,
screw type insulating connectors and all other
fixing accessories. No 2
7.2 Surface mounted 6 W ceiling loudspeaker type
BOSCH / PHILIPS or equivalent. No 2
8 Fire Alarm System
8.1 Analogue addressable fire alarm system points
fed through fire alarm cables of 4x1.5 sq.mm in
thermopastic conduit of minimum diameter No 130 -
21mm.
8.2 Surface mounted analogue addressable optical
smoke detector of approved quality. No 111 -
8.3 Surface mounted analogue addressable constant
temprature heat detector of approved quality. No 2 -
8.4 Surface mounted analogue addressable break
glass manual switch. No 5 -
8.5 Surface mounted analogue addressable sounder. No 12 -
8.6 Analogue addressable fire detection and alarm
system panel type GST or approved equivalent to
accommodate total of 150 line devices. No 1 -
9 Nurse Call System
Supply, install, test and commission Nurse call
system complete as per drawing and the
following specification:-
9.1 Door units type Legrand 782 52 fed through PVC
wires of 2(2x1.0) Sq.mm in thermoplastic
conduit of minimum diameter 19 mm in/or under
surface including junction box with cover and No 6 -
screw type insulating connectors.
9.2 Dual display corridor bulk units type Legrand 782
63 fed through PVC wires of 2(2x1.0) Sq.mm in
thermoplastic conduit of minimum diameter 19
mm in/or under surface including junction box
with cover and screw type insulating connectors.
No 6 -
MAIN BUILDING BOQ
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
9.3 Socket for push button cord and push button cord
units type Legrand 782 59 + Legrand 783 62 fed
through PVC wires of 2x1.0 Sq.mm in
thermoplastic conduit of minimum diameter 16
mm in/or under surface including junction box
with cover and screw type insulating connectors.
No 6 -
9.4 Flush mounted distribution board in sheet metal
type Siemens, Legrand, ABB or approved
equivalent with lockable door and with all its
accessories consisting of :-
One piece of power supply module type Legrand
782 89 or approved equivalent.
Two pieces of 3-way management module type
Legrand 782 12 or approved equivalent.
and with reserve space. No 1 -
9.5 Supply and install table top control unit type
Legrand 782 14 consisting of one 6-way call
display unit type Legrand 782 13 including all No 1 -
necessary wiring.
10 Feeder Lines
10.1 Supply power from MDB-MC to SDB-MED-GF,
SDB-LAB-GF and SDB-OFC-1F through PVC
insulated and PVC sheathed copper cable of 5x10
sq.mm in PVC conduit of minimum f 50mm.
m 120 -
10.2 Supply power from MDB-MC to SDB-GYN-GF
through PVC insulated and PVC sheathed copper
cable of 5x16 sq.mm in PVC conduit of
minimum f 50mm.
m 33 -
10.3 Supply power from MDB-MC to SDB-LIB-1F
through PVC insulated and PVC sheathed copper
cable of 3x10 sq.mm in PVC conduit of m 22 -
minimum f 50mm.
10.4 Supply power from MDB-MC to SDB-OFC-2F
through PVC insulated and PVC sheathed copper
cable of 3x16 sq.mm in PVC conduit of minimum
f 50mm. m 50 -
8. SANITARY INSTALLATION
I. INTERNAL SANITARY INSTALLATION
1. SANITARY FIXTURES
TOILET ACCESSORIES
a Size
Supply:- 800
and xinstall
600 mmfloor drain ,made of Set 38.00 -
enameled cast iron complete with removable &
1.10 slotted cover .
a ф20 mm ml 400.00 -
b ф25 mm ml 220.00 -
c ф32 mm ml 120.00 -
MAIN BUILDING BOQ
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
d ф40 mm ml 55.00 -
MAIN BUILDING BOQ
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
b 1" No 15.00 -
c 1¼" No 10.00 -
d 1½" No 10.00 -
a ф50 mm ml 210.00 -
b ф80 mm ml 75.00 -
c ф110 mm ml 250.00 -
MAIN BUILDING BOQ
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
a ф50 mm No 15.00 -
b ф80 mm No 10.00 -
c ф110 mm No 25.00 -
a ф80 mm No 10.00 -
a ф25 mm ml 65.00 -
b ф32 mm ml 45.00 -
c ф40 mm ml 150.00 -
d ф50 mm ml 30.00 -
a 1" No 12.00 -
b 1¼" No 5.00 -
c 1½" No 16.00 -
d 2" No 4.00 -
a ¾" No 4.00 -
a 1½" No 1.00 -
a ф32 mm ml 25.00 -
b ф40 mm ml 10.00 -
a 1¼" No 4.00 -
b 1½" No 6.00 -
a ф160 mm ml 75.00 -
b ф200 mm ml 250.00 -
a ф110 mm ml 110.00 -
B. SUPER STRUCTURE
1 CONCRETE WORK BIRR -
3 ROOFING BIRR -
2. CONCRETE WORK
2.1 Reinforced sub structure concrete
2.1.1 5cm thick Lean Concrete class C-5 with
minimum cement content of 150kg/m3. under m2 21.60 -
2.1.2 C-25 in footing pad m3 8.64 -
2.1.3 C-25 in grade Beam m3 10.50 -
2.1.4 C-15 in ground floor slab m 3
3.75 -
2.2 FORMWORK
Sub structure normal finish to:-
2.2.1 to footing pad m² 28.80 -
2.2.2 to grade Beam m² 21.00 -
2.3 Reinforcement
2.3.1 Diameter, 8mm kg 375.25 -
2.3.2 Diameter, 16mm kg 1,279.80 -
3. MASONERY WORK
50cm thick sound stone foundation wall built in
2.3 cement mortar mix. 1:4 m3 22.50 -
2. BLOCK WORK
1.3 50cm thick stone masonry wall m3 75.00 -
3. ROOFING
Construct avarage thickness of 12cm thick light
weight concrete over concrete roof slab. m2 25.00 -
3.1 Construct 3cm thick screed over light weight
concrete to receive water proofing material m2 25.00 -
3.2 Apply membrane waterproofing material over the
screed as per manufactures instruction . m2 25.00 -
3.3
TOTAL CARRIED TO SUMMARY ……………………………………… -
CONTAINER WALL SUMMARY
A. SUB STRUCTURE
1 EXCAVATION WORK & EARTH WORK BIRR -
B. SUPER STRUCTURE
1 CONCRETE WORK BIRR -
2. CONCRETE WORK
5cm thick lean concrete in C-5 150kg cement/
m3
2.1 Under footing m2 8.64 -
2.2 Under stone masonry foundation m 2
18.00 -
Reinforced concrete C-25 360kg cement/ m 3
3. MASONARY WORK
3.1 50cm thick trichitic stone masonry foundation
wall m3 30.00 -
B. SUPER STRUCTURE
1. CONCRETE WORK
Reinforced concrete C-25 360kg cement/ m3
1.1 in elevation column m3 1.50 -
1.2 in top tie beam m 3
2.75 -
1.3 in wall cladding m3 7.20 -
CONTAINER WALL TREATMENT BOQ
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
Provide and fix in position metal formwork to
1.4 elevation column m2 24.00 -
1.5 top tie beam m 2
12.00 -
1.6 wall cladding m2 72.00 -
Steel reinforcement according to structural
drawings. Price shall include cutting, bending,
placing in position, tying wires steel specer or
blocks
1.7 a) Diameter, 8mm kg 85.32 -
1.8 b) Diameter, 12mm kg 703.30 -
2. MASONARY WORK
2.1 20cm thick hollow concrete block wall bedded in
compo mortar (1:2:9) one side left for plastering m2 48.00 -
3. FINISHING WORK
3.1 Apply two coats of plastering to external wall,
exposed stone, beam and column surfaces with
smooth edges around openings m2 84.00 -
3.2 Ditto but apply final coat of 1:2:9 plastering to all
surfaces. m2 84.00 -
3.3 Provide and fix 2cm thick marble copping to
HCB wall top surface ml 12.00 -
3.4 Provide and apply quartz painting to all plastered
surface, (color and pattern to be approved) m2 84.00 -
B. SUPER STRUCTURE
1 CONCRETE WORK BIRR -
3 ROOFING BIRR -
6 GLAZING BIRR -
7 PAINTING BIRR -
2. CONCRETE WORK
5cm thick lean concrete in C-5 150kg cement/ m 3
2.1 Under footing m2 8.64 -
Reinforced concrete C-25 360kg cement/ m 3
B. SUPER STRUCTURE
1. CONCRETE WORK
Reinforced concrete C-25 360kg cement/ m 3
1.1 in elevation column m3 1.00 -
1.2 in floor slab m 3
20.00 -
1.3 in top tie beam m 3
0.50 -
Provide and fix in position metal formwork to
1.4 in elevation column m2 16.00 -
1.5 in sides of floor slab m2 8.00 -
Steel reinforcement according to structural
drawings. Price shall include cutting, bending,
placing in position, tying wires steel specer or
blocks
1.7 a) Diameter, 8mm kg 28.44 -
1.8 b) Diameter, 12mm kg 63.94 -
BRIDGE OR RAMP BOQ
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
2. MASONARY WORK
2.1 20cm thick hollow concrete block wall bedded in
compo mortar (1:2:9) on both side left for
plastering m2 10.00 -
3. ROOFING
3.1 Roofing in poly carbonate material to be fixed on
the metal structure by means of bolt all as per the
detail drawing and manufacturer detail. Price
shall include all metal beam, bracing & roof
structure 80x80x3mm RHS and one coat of anti
rust paint and two coat of synthetic oil paint
m2 20.00 -
3.2 Roof gutter in G-28 galvanized flat metal sheet
including all the necessary fixing accessories and
20cm x 2.5cm fascia board development length
70cm
ml 8.00 -
3.3 Diameter 10 PVC down pipe including fixing
accessories m2 8.00 -
4. ALMUNIUM WORK
4.1 Aluminum framed windows, doors & window
doors should be in white poweder coated
aluminum frame and 5mm thick tempered glass
complete with locks, handles and all acessories.
Wall thickness of alumnium should be 2mm
plated should be 3mm Iodization thickness of
alumnium should be 15 - 20 micro meter. All
accessories should be of the same quality
standard as that of the main frame. Use 0.8mm
thick alumnium panel for doors covered part.
Window
W1 :- 150 x 180cm Pcs 4.00 -
5. FINISHING WORK
5.1 Apply two coats of plastering to all wall, column
and beam surfaces with smooth edges around
openings m2 44.00 -
5.2 Ditto but apply final coat of 1:2:9 plastering to all
surfaces. m2 44.00 -
5.3 Supply and fix high quality 40 x 40cm porcelain
floor tiles. m2 20.00 -
BRIDGE OR RAMP BOQ
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
5.4 Supply and fix 16cm high porcelain skirting ml 16.00 -
5.5 Supply and fix 2cm thick white marble window ml 20.00 -
5.6 sill
Supply and fix 2mm thick PVC ceiling (color to
be approved) price shall include, 4x5cm wooden
battens @ 60cm c/c both ways m2 24.00 -
6. GLAZING
6.1 Supply and fix 5mm thick clear sheet glass with
gasket into frames m2 8.00 -
7. PAINTING
7.1 Apply three coats of synthetic plastic paint to
internal wall, column and beam surfaces m2 22.00 -
7.2 Apply quartz paint to all external plastered
surfaces (pattern and color to be approved) m2 22.00 -
B. SUPER STRUCTURE
1 CONCRETE WORK BIRR -
5 GLAZING BIRR -
6 PAINTING BIRR -
2. CONCRETE WORK
5cm thick lean concrete in C-5 150kg cement/ m 3
2.1 Under footing m2 11.50 -
2.2 Under stone masonry foundation m 2
10.00 -
Reinforced concrete C-25 360kg cement/ m 3
B. SUPER STRUCTURE
1. CONCRETE WORK
Reinforced concrete C-25 360kg cement/ m 3
1.1 in elevation column 2.00 -
1.2 in floor slab 13.50 -
1.3 in top tie beam 2.80 -
Provide and fix in position metal formwork to
1.4 in elevation column 32.00 -
1.5 in top tie beam 45.00 -
Steel reinforcement according to structural
drawings. Price shall include cutting, bending,
placing in position, tying wires steel specer or
blocks
1.7 a) Diameter, 8mm 616.00 -
1.8 b) Diameter, 12mm 308.00 -
LIBRARY BOQ
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
2. MASONARY WORK
2.1 20cm thick hollow concrete block wall bedded in
compo mortar (1:2:9) on both side left for
plastering m2 14.26 -
Ditto to 15cm thick hollow concrete block wall m2 387.80 -
4. ALMUNIUM WORK
4.1 Door
D1 :- 100 x 210cm Pcs 13 -
Window
W1 :- 150 x 180cm Pcs 7 -
5. FINISHING WORK
5.1 Apply two coats of plastering to all wall, column
and beam surfaces with smooth edges around
openings m2 804.12 -
5.2 Ditto but apply final coat of 1:2:9 plastering to all
surfaces. 804.12 -
5.3 Supply and fix high quality 40 x 40cm porcelain
floor tiles. m2 210.00 -
5.4 Supply and fix 16cm high porcelain skirting ml 45.00 -
5.5 Supply and fix high quality non slipper ceramic
floor tiles. m2 251.56 -
5.6 Supply and fix 10cm high ceramic skirting ml 25.00 -
5.7 Supply and fix 2cm thick white marble window
sill
Size: ml 10.50 -
5.8 Supply and fix 2mm thick PVC ceiling (color to
be approved) price shall include, 4x5cm wooden
battens @ 60cm c/c both ways m2 251.56 -
6. GLAZING
6.1 Supply and fix 5mm thick clear sheet glass with
gasket into frames 18.90 -
7. PAINTING
7.1 Apply three coats of synthetic plastic paint to
internal wall, column and beam surfaces m2 804.12 -
7.2 Apply quartz paint to all external plastered
surfaces (pattern and color to be approved) m2 102.00 -
LIBRARY BOQ
ITEM DESCRIPTION UNIT QTY RATE AMOUNT
3 ROOFING BIRR -
2. METAL WORK
2.1 Erect steel metal post for covered walkway
kg
100x100x3mm RHS @ 5m c/c. 4704.00 -
2.2 80x80x3mm RHS kg 1170.00 -
2.3 60x60x3mm RHS kg 2509.80 -
3. ROOFING
3.1 Roof covering in EGA 500 fixed on steel truss purlin
in RHS by means of bolt all as per the detail drawing
and manufacturer detail. Price shall include all metal
beam, bracing & roof structure 80x80x3mm RHS
and one coat of anti rust paint and two coat of
synthetic oil paint
m2 280.00 -
3.2 Apply galvanized G-28 Gutter ml 45.02 -
3.3 Down pipe ,100 mm PVC ml 22.00 -
3 ROOFING BIRR -
2. METAL WORK
2.1 Erect steel metal post for covered walkway
100x100x3mm RHS @ 4m c/c. Price shall include
one coat of anti rust paint and two coat of synthetic
oil paint
kg 985.60 -
3. ROOFING
3.1 Roofing in poly carbonate material to be fixed on the
metal structure by means of bolt all as per the detail
drawing and manufacturer detail. Price shall include
all metal beam, bracing & roof structure 80x80x3mm
RHS and one coat of anti rust paint and two coat of
synthetic oil paint.
m2 90.00 -
3.2 Apply galvanized G-28 Gutter ml 100.43 -
3.3 Down pipe ,100 mm PVC ml 36.00 -
1. LANDSCAPING WORK
1.1 Excavation for landscape area to remove topsoil to an
average depth of 75cm m3 34.03 -
1.2 Cart away surplus material not exceeding 10km from
the site m3 34.03 -
1.3 Fill under hard core with average thickness of 40cm
selected granular material brought from outside the
site well palled and compacted with every 20cm vice
using 10-tome roller m3 18.15 -
1.4 25cm hard core under road m 2
20.74 -
1.5 10cm thick R.C. slab m2 20.74 -
1.6 Curb stone made of C-20 concrete filled into
formwork and vibrated around rod reinforcement.
(price includes steel and formwork) ml 41.46 -
1.7 Supply & fix 5cm thick colored cement tile floor
bedded and joint grouted in cement and mortar mix
(1:3) price shall includes 3cm thick cement and sand
mortar bedding m2 20.74 -
1.8 2.2 horse power capacity water pump Pcs 1.00 -
1.9 Φ20mm water supply pipe with all accessories ml 20.00 -
1.10 Φ20mm drainage pipe with all accessories ml 20.00 -
1.11 10cm thick, 100cm x 60cm x 40cm high R.C. water
storage, both sides finished with mosaic. Pcs 1.00 -
1.12 Rock, garden, overall diameter 400cm, composed of
rever side rocks of various sizes, bolders, cactus trees
and plants that are appropriate for the purpose.
Pcs 1.00 -