Major 培训内容 Training Content Electrical: CCO Generator and Excitation System: relative operation code, system diagrams, operation sheets, inspection items, operation parameters, specifications, regular work, accident handling and measures.Measures to Prevent Operation Accident in Switchgear Room Boiler: 炉前燃油及微油点火系统运行方式及参数、系统图、定期工作、投停步骤条件、相关联锁、事故处理 Operation mode and parameters of fuel and micro-oil ignition system of the furnace, system diagram, regular work, conditions of operation and shutdown steps, related interlocks, and accident handling Turbine: 大小机润滑油、密封油、系统运行方式及参数、系统图、定期工作、投停步骤条件、相关联锁、事故处理 Lube oil and seal oil of main turbine and BFPTs, system operating methods and parameters, system diagrams, regular work, conditions of operation steps, related interlocks, and accident handling EH 油系统图, 油净化装置及外置油净化装置运行方式及参数、定期工作、投停步骤、事故处理 EH oil system diagram, operation mode and parameters of oil purification device and external oil purification device, regular work, steps of putting on and off, accident handling Simulator: EH oil pump trips Large and small lubricating oil pumps trip Large and small lubricating oil coolers leak Turbine oil cooler outlet regulating valve failure Generator AC seal oil pump B trip (A standby is not connected to start) BFPT A fault-trip Safety: Firefighting Water System Thermal and Mechanical Safety: Appendix A - A2 Fire aid for electric shock (A2.1, A2.2, A2.3, A2.4) Topic 3.1 Basic provisions for operation and maintenance of coal storage and conveying equipment (Pages 42-44) Operation Code: Chapter 2 – Water Source and Raw Water Pre-treatment System (2.1) Chapter 2 – Water Source and Raw Water Pre-treatment System (2.2) Chapter 2 – Water Source and Raw Water Pre-treatment System (2.3.1–2.3.6) Chapter 2 – Water Source and Raw Water Pre-treatment System (2.3.7) Chapter 2 – Water Source and Raw Water Pre-treatment System (2.4) Safety: CHO 10 Prohibitions and Epidemic Prevention Regulations Management Standard for PTW and Operation Sheet (3.1 – 3.7) Management Standard for PTW and Operation Sheet (3.8 – 3.14) Management Standard for PTW and Operation Sheet (4.5) Management Standard for PTW and Operation Sheet (5.2) Firefighting Water System Thermal and Mechanical Safety: Appendix A - A2 Fire aid for electric shock (A2.1, A2.2, A2.3, A2.4) Electrical: FGD FGD 10KV diagram Training Lecture: What are interlock protection trip conditions of FGD system and oxidation air system? Control of lower pH of absorber in a situation where limestone purity is below 80% What are interlock protection conditions of vacuum belt system? Operation measures for rain water pumps Operation measures for ash conveying Problem Analysis Why gypsum quality is poor these days? Reason of low pressure of limestone hydrocyclone B? How was it dealt? What is the effect of oxidation air in absorber system? What problem was faced when the blowers inlets were opened less than 50%? Causes and handling of rain water pumps when it stopped suction? Causes and handling of high pressure at outlet of ash hopper fluidizing blower Operation Code: Operation of FGD sub-systems (3.1-3.2) Operation of FGD sub-systems (3.3-3.4) Operation of FGD sub-systems (3.5-3.6) Operation of FGD sub-systems (3.7-3.8) Operation of FGD sub-systems (3.9-3.10) Diagram: FGD flue gas system diagram Oxidation air system diagram Safety: Anti-violation management standards Shortcomings in Fuel oil foam Fire fighting drill Firefighting Water System Thermal and Mechanical Safety: Appendix A - A2 Fire aid for electric shock (A2.1, A2.2, A2.3, A2.4) Topic 1.0 General Provisions (Pages 1-15) Training: Boiler Chemical Cleaning - Pickling Reagent preparation for Copper testing Surface Tension instrument QCD HCl Standardization Quality of Sodium Hypochlorite Safety: Thermal and Mechanical Safety: Appendix A - A2 Fire aid for electric shock (A2.1, A2.2, A2.3, A2.4)