Professional Documents
Culture Documents
25-Oct-09 0
Date Revision Description Calc. by Checkd. By Appd. By
REVISION HISTORY
AL JAIDAH AND SONS
TENTS AND UMBRELLA TRADING CO
INDUSTRIAL LINE -18 DOOR -54 QATAR
3100
20
0
0.43
COMMERCIAL 95 PRE
KNITTED SHADE CLOTH
Y = C + SAG
S2 + C 2 = Y 2
S2 + C2 = ( C + 0.2 ) 2
S2 + C2 = C2 + 0.4 C + 0.04
S = ( 0.4 C + 0.04 )
X = C ln (( S + Y ) / C )
TRY C = L2 / ( 8 * SAG )
C = 3.12 / ( 8 * 0.2 ) = 6m
1.55 » 1.54 OK
S = ( 0.4 * 6 + 0.04 )
S = 1.56
Y = 6 + 0.2
= 6.2
T = 0.43 * 6.2
= 2.66 kN/m
635 daN / 5 cm
8100
50
0
2.66
Y = C + SAG
S2 + C 2 = Y 2
S2 + C2 = ( C + 0.5 ) 2
S2 + C2 = C2 + 1.0 C + 0.25
S = ( 1.0 C + 0.25 )
X = C ln (( S + Y ) / C )
TRY C = L2 / ( 8 * SAG )
4.05 » 4.03 OK
S = 4.08
Y = 16.4 + 0.5
= 16.9
T = 2.66 * 16.9
= 44.95 Kn
DESIGN REFERENCE
BS 5950 part 1: 2000 Structural use of Steel (Code of Practice for Design - Rolled and Welded Section)
DESIGN CONSIDERATION
Soil Bearing Capacity 100 kPa ( Assumed; subject for soil investigation report )
DEAD LOAD
m
6
SHADENET + FRAMING = 0.05 kN/m2
WIND LOAD
( Ground roughness, Bldg size, Height = 0.68 ( table 3 of CP3 Chap V part 2)
above ground , country with many
windbreak, ), S2
Reduction factor for free standing multibay canopy roofs (on second bay)
on Maximum ( + ) = 0.87
On Minimum ( - ) = 0.64
Canopy Wind Pressure, = 0.57*0.4*0.87 = 0.19 kN/m2
= 0.57*1.2*0.64 = 0.43 kN/m2
Member Section
Rafter Pipe = 4.0 mm x 2.5" dia pipe
AL JAIDAH AND SONS
TENTS AND UMBRELLA TRADING CO
INDUSTRIAL LINE -18 DOOR -54 QATAR
since the wind pressure coefficient on roof varies by zone total wind pressure reduce by 15% consider a 15% reduction of the total pressure on roof
Downward force due to wind and weight of canopy roof ( case 1 ) 8.1m
= 49.91 * 0.19 * 85% + 49.91 * 0.05
= 10.55 kN
3.
1
Upward force due to wind ( case 2 ) 3.1
6
m
2.0m
= 49.91 * 0.43
= 21.46 * 85%
= -18.24 kN
L = ( 0.78 + 4.27 )
2 2 1/2
= 4.34 m
RAFTER PIPE
Section property of 2.5" mm dia pipe 4.0 mm thick
BASE CONNECTION
350 mm x 350 mm x 20 mm thk base plate with 4 nos of M25 Grade 8.8 Anchor Bolt with embedment length of 600 mm
T = 115.6 kN
T = 15.37 / 4
= 3.84 kN
total = 119.4 kN
350
40 270 40
40
12mm thk
40
STIFFENER PLATE
AL JAIDAH AND SONS
TENTS AND UMBRELLA TRADING CO
INDUSTRIAL LINE -18 DOOR -54 QATAR
1600
1200