Professional Documents
Culture Documents
08
2 Author: xlabidiwa Subject: Sticky Note Date: Regarding Note 1: The uncertainty of sales gas flowrate measurement is indicated on Skid vendor control description and philosophy doc NAWGTP ABBOGC PF02
23/12/2015 10:56:05 Please specify the measuring range for with 270 CI SPE 0010.
uncertainty 1% or more. In partcular, the uncertainty trend is shown on NAWGTP ABBOGC PF02 270 CI SPE 00101 rev C02, page 11. Based on such graph, one can deduce
Please confirm that metering skid will ensure the following :
fiscal accuracy of 1% on mass flow down to
0.14 MSm3/d. a) from 0.14 to 0.4 MSm3/d max uncertainty is 3% (0.14 MSm3/d is 15.56% (0.14/0.9) of a single run max flowrate which is 0.9 MSm3/d; 0.4
MSm3/d is 45% of single max flowrate)
3 Author: xlabidiwa Subject: Sticky Note Date: To add oil filters for the sales gas metering According to Siemens reply to HAZOP action 18# of Sales Gas fiscal metering Hazop session, oil filters are not required.
23/12/2015 10:56:23 skid.
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
12/04/2016
APPROVED FOR
CONSTRUCTION
Date: _______
03/12/2015 Sign: ____________
09/02/2015
08/04/15