Finding Description
1. The Front sill and Door sill has dented (underneath)
2. The Bottom side rail (right side) has dented
3. The Left side panel has dented
4. The roof panel has corroded and many hole

Recommendation Repair Method


1. Repair the front sill and door sill that has been dented (do not use the heating method)
2. Repair the bottom side rail that has been dented (do not use the heating method)
3. Repair the Left side panel that has dented
4. Repair the leaking roof with cut it and then welded with new plate
5. Make sure there are no leaks after repairing the leaky roof
6. Repaint the corroded parts

Acceptance criteria:
1. BP Procedure 100572 - Management of Lifting Operations and Lifting Equipment

2. BS ISO 1496-1:2013 - Series 1 freight containers — Specification and testing, Part 1: General cargo containers for general purposes

Name of the person making this report:

Nahrowi Aditya Darmawan


Liffting Gear Inspector
Page 1 of 2
QUALITY REPORT AND
RECOMMENDATION
This report complies with Lifting Operations and Lifting Equipment Regulations 1998 (SI 2307)
Date of report: April 13, 2021 QRR Number: QRR.0016.LG29.L2.IV.2021
Owner: BP Indonesia Location: BP Sorong, POSB
Tag Number BPBU 295043 6 Type of examination: Visual
Type of Container Dry ISO Container 20Ft Date of Inspection: April 13, 2021

PHOTOGRAPHIC REPORT

Fig 1. View of BPBU 295043 6 Fig 2. View of front sill has dented Fig 3. View of door sill has dented

Fig 4. View of bottom side rail has dented Fig 5. View of Roof panel from outside Fig 6. View of Roof panel from inside

Page 2 of 2

You might also like