You are on page 1of 2

QUALITY REPORT AND

RECOMMENDATION
Date of report: April 13, 2021 QRR Number: QRR.0019.LG29.L2.IV.2021
Owner: BP Indonesia Location: BP Sorong, POSB
Tag Number BPBU 295075 5 Type of examination: Visual
Type of Container Dry ISO Container 20Ft Date of Inspection: April 13, 2021
Finding Description
1. The door sill has corroded and dented
2. The front sill sill has corroded, porous, dented and torn
3. The cross member has corroded and porous
4. Broken hinges on right and left door
5. The bottom door frame has corroded and porous
6. The door gasket (left door) has broken
7. Roof panel has corroded, many hole and concave
8. The Wooden Floor has damaged and rotten due to rain from the leaking roof

Recommendation Repair Method


1. Provide WPS, Drawing, Material certificate and Welder certified before repair
2. Repair the door sill that has dented
3. Replace the front sill with the thick plate according to the original
4. After repair should be perform NDT before load test
5. Ensure that the load tests are carried out in accordance with correct procedures and standards according to the BP requirements
6. After load test should be perform NDT on the Lifting points and repaired welds
7. Replace the cross member with the thick plate according to the original
8. Repair the broken hinge with replace the pin inside
9. Replace the bottom door frame that has been porous with the thick plate according to the original
10. Repair the door gasket has broken
11. Roof panel should be replace with new roof panel
12. Ensure the new roof panel installed correctly (no convex or concave)
13. Perform leak test on the roof panel after replaced
14. Ensure roof ID Marking are installed correctly
15. The Wooden floor has damaged and rotten must be replaced with new wooden floor (according to ISO Container Standard)
Acceptance criteria:
1. BP Procedure 100572 - Management of Lifting Operations and Lifting Equipment

2. BS ISO 1496-1:2013 - Series 1 freight containers — Specification and testing, Part 1: General cargo containers for general purposes

Name of the person making this report:

Nahrowi Aditya Darmawan


Liffting Gear Inspector
Page 1 of 2
QUALITY REPORT AND
RECOMMENDATION
This report complies with Lifting Operations and Lifting Equipment Regulations 1998 (SI 2307)
Date of report: April 13, 2021 QRR Number: QRR.0018.LG29.L2.IV.2021
Owner: BP Indonesia Location: BP Sorong, POSB
Tag Number BPBU 295075 5 Type of examination: Visual
Type of Container Dry ISO Container 20Ft Date of Inspection: April 13, 2021

PHOTOGRAPHIC REPORT

Fig 1. View of BPBU 295075 5 Fig 2. View of front sill has corroded and porous Fig 3. View of door sill has dented

Fig 4. View of cross members has corroded and Fig 5. View of broken hinge on right and left Fig 6. View of bottom door frame has corroded
porous door and porous

Fig 7. View of wooden floor has damaged and


Fig 8. View of roof panel from inside Fig 9. View of roof panel from outside
rotten
Page 2 of 2