LICCON ERROR CODE (LEC)

LTM 1080/1
002389508
29.10.2003

LIEBHERR-WERK EHINGEN GMBH, Postfach 1361, D-89582 Ehingen/Donau


Tel 0049 7391 502-0, Fax 0049 7391 502-3399
www.lwe.liebherr.de, E-mail: info@lwe.liebherr.com
LICCON ERROR CODE (LEC)

Reference Identification number Illustration number

Electrics Superstructure 982875508 3363 932 02 00 001 000

Electrics Carrier 982868208 3263 920 01 00 001 001

Error list -256712 9106-700.00.00.000-013


Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

000001 ZE 0: system error OS-HC11 (observe parameters) initialising error processor-register erroneous E 2
no crane operation possible
with regular occurrence --> replace ZE

000002 ZE 0: system error OS-HC11 (observe parameters) initialising error test total in EPROM/FLASH erroneous E 2
no crane operation possible
check program memory card or ZE

000006 ZE 0: system error OS-HC11 (observe parameters) initialising error RAM erroneous E 2
no crane operation possible
with regular occurrence --> replace ZE

000007 ZE 0: system error OS-HC11 (observe parameters) UART erroneous E 2


no crane operation possible
with regular occurrence --> replace ZE

000010 ZE 0: system error OS-HC11 (observe parameters) system routine inaccessible E 2


entry in error memory, all crane movements will be stopped

000011 ZE 0: system error OS-HC11 (observe parameters) ZE-watchdog expired E 2


entry in error memory, all crane movements will be stopped
check ZE

000012 ZE 0: system error OS-HC11 (observe parameters) type-identification in EPROM erroneous E 2


entry in error memory, no crane operation possible
check program memory card

000013 ZE 0: system error OS-HC11 (observe parameters) test total in EPROM/FLASH erroneous E 2
entry in error memory, all crane movements will be stopped
check program memory card

000014 ZE 0: system error OS-HC11 (observe parameters) program already running E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000015 ZE 0: system error OS-HC11 (observe parameters) program not available E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

002389508 1
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

000016 ZE 0: system error OS-HC11 (observe parameters) system-, driver-watchdog expired E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000017 ZE 0: system error OS-HC11 (observe parameters) total of CPU-time distribution too great E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000018 ZE 0: system error OS-HC11 (observe parameters) arithmetic overflow (16 Bit) E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000019 ZE 0: system error OS-HC11 (observe parameters) division through zero (16 Bit) E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000020 ZE 0: system error OS-HC11 (observe parameters) task-watchdog expired E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000021 ZE 0: system error OS-HC11 (observe parameters) illegal opcode trap E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

000022 ZE 0: system error OS-HC11 (observe parameters) task inactive E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000023 ZE 0: system error OS-HC11 (observe parameters) program incapable of running (type identification) E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000024 ZE 0: system error OS-HC11 (observe parameters) task already used E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000025 ZE 0: system error OS-HC11 (observe parameters) realtime-module already used E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

002389508 2
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

000026 ZE 0: system error OS-HC11 (observe parameters) regulator-module already used E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000030 ZE 0: system error OS-HC11 (observe parameters) unacceptable bank address E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000041 ZE 0: system error OS-HC11 (observe parameters) arithmetic error E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000044 ZE 0: system error OS-HC11 (observe parameters) output parameter without effect, from inactive output E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000045 ZE 0: system error OS-HC11 (observe parameters) entry parameter undefined, from inactive input E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000046 ZE 0: system error OS-HC11 (observe parameters) impermissible regulator parameter E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000047 ZE 0: system error OS-HC11 (observe parameters) realtime-control block not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000048 ZE 0: system error OS-HC11 (observe parameters) realtime-control block inactive E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000049 ZE 0: system error OS-HC11 (observe parameters) urgent modul, ZE not available E 2
entry in error memory, no crane operation possible
check ZE

000050 ZE 0: system error OS-HC11 (observe parameters) file not available E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

002389508 3
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

000051 ZE 0: system error OS-HC11 (observe parameters) file already opened E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000052 ZE 0: system error OS-HC11 (observe parameters) file not open on close E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000053 ZE 0: system error OS-HC11 (observe parameters) system mask not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000054 ZE 0: system error OS-HC11 (observe parameters) system text not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000055 ZE 0: system error OS-HC11 (observe parameters) symbol not available E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000056 ZE 0: system error OS-HC11 (observe parameters) invalid mark in symbol E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000057 ZE 0: system error OS-HC11 (observe parameters) default load chart missing E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000058 ZE 0: system error OS-HC11 (observe parameters) amplifier erroneous or return power feed E 2
entry in error memory, all crane movements will be stopped
check wiring

000059 ZE 0: system error OS-HC11 (observe parameters) subroutine not reenterant E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

000060 ZE 0: system error OS-HC11 (observe parameters) transmission error SCI E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

002389508 4
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

000061 ZE 0: system error OS-HC11 (observe parameters) SCI-BREAK E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

000062 ZE 0: system error OS-HC11 (observe parameters) SCI not connected E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

000063 ZE 0: system error OS-HC11 (observe parameters) monitor error in operation E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

000065 ZE 0: system error OS-HC11 (observe parameters) impermissible bus address E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

000066 ZE 0: system error OS-HC11 (observe parameters) ADC working outside the permissible tolerance E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

000067 ZE 0: system error OS-HC11 (observe parameters) arithmetic processor not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

000068 ZE 0: system error OS-HC11 (observe parameters) impermissible interrupt E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

000070 ZE 0: system error OS-HC11 (observe parameters) various structure versions E 2


entry in error memory, no crane operation possible
with regular occurrence --> replace ZE

000071 ZE 0: system error OS-HC11 (observe parameters) structure data missing E 2


entry in error memory, no crane operation possible
with regular occurrence --> replace ZE

000072 ZE 0: system error OS-HC11 (observe parameters) structure entry senseless E 2


entry in error memory, no crane operation possible
with regular occurrence --> replace ZE

002389508 5
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

000073 ZE 0: system error OS-HC11 (observe parameters) interpreter error E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

000074 ZE 0: system error OS-HC11 (observe parameters) transformation ASCII to BIN erroneous E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

000075 ZE 0: system error OS-HC11 (observe parameters) SPI-error E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

000076 ZE 0: system error OS-HC11 (observe parameters) incorrectly inserted power unit E 2
entry in error memory, all crane movements will be stopped
check memory card in power supply unit

000077 ZE 0: system error OS-HC11 (observe parameters) BAF-call-up erroneous E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

000078 ZE 0: system error OS-HC11 (observe parameters) impermissible parameter E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

000079 ZE 0: system error OS-HC11 (observe parameters) no right of access E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

000080 ZE 0: system error OS-HC11 (observe parameters) fatal internal software error E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

000081 ZE 0: system error OS-HC11 (observe parameters) stack overflow E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

000082 ZE 0: system error OS-HC11 (observe parameters) hardware-watchdog erroneous E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

002389508 6
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

000094 ZE 0: system error OS-HC11 (observe parameters) transmission error parallel bus E 2
entry in error memory, all crane movements will be stopped
check ZE, bus circuit board, power supply unit

000095 ZE 0: system error OS-HC11 (observe parameters) DMA-error E 2


entry in error memory, all crane movements will be stopped
check ZE, bus circuit board, power supply unit

000099 ZE 0: system error OS-HC11 (observe parameters) TMS-error E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

002001 ZE 0: system error OS-TMS initialising error processor-register erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

002002 ZE 0: system error OS-TMS initialising error test total in EPROM/FLASH erroneous E 2
entry of error in error memory, all crane movements will be stopped
replace ZE

002006 ZE 0: system error OS-TMS initialising error RAM erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

002007 ZE 0: system error OS-TMS UART erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

002020 ZE 0: system error OS-TMS task-watchdog expired E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

002021 ZE 0: system error OS-TMS illegal opcode trap E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

002082 ZE 0: system error OS-TMS hardware-watchdog erroneous E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

002389508 7
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

010070 ZE 0: output 0 measuring system defect X70:16 O-76.3 E 1


no crane operation possible, entry in error list
replace central unit

010071 ZE 0: output 0 short circuit to ground or transistor defect X70:16 O-76.3 E 1


no crane operation possible, entry in error list
check lines, replace central unit

010072 ZE 0: output 0 outside source feeding X70:16 O-76.3 E 1


no crane operation possible, entry in error list
check lines

010073 ZE 0: output 0 open circuit or short circuit to supply voltage/ground X70:16 O-76.3 E 1
entry in error list
re-start, check lines

010170 ZE 0: output 1 measuring system defect X70:17 O-79.3 E 1


no crane operation possible, entry in error list
replace central unit

010171 ZE 0: output 1 short circuit to ground or transistor defect X70:17 O-79.3 E 1


no crane operation possible, entry in error list
check lines, replace central unit

010172 ZE 0: output 1 outside source feeding X70:17 O-79.3 E 1


no crane operation possible, entry in error list
check lines

010173 ZE 0: output 1 open circuit or short circuit to supply voltage/ground X70:17 O-79.3 E 1
entry in error list
re-start, check lines

010260 ZE 0: output 2 safety chain error, diode defect or safety contact sticking X70:18 O-69.1 E 1
report of error, otherwise no reaction
checking of safety contact and diode

010270 ZE 0: output 2 measuring system defect X70:18 O-69.1 E 1


no crane operation possible, entry in error list
replace central unit

002389508 8
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

010271 ZE 0: output 2 short circuit to ground or transistor defect X70:18 O-69.1 E 1


no crane operation possible, entry in error list
check lines, replace central unit

010272 ZE 0: output 2 outside source feeding X70:18 O-69.1 E 1


no crane operation possible, entry in error list
check lines

010273 ZE 0: output 2 open circuit or short circuit to supply voltage/ground X70:18 O-69.1 E 1
entry in error list
re-start, check lines

010360 ZE 0: output 3 safety chain error, diode defect or safety contact sticking X70:19 O-75.4 E 1
report of error, otherwise no reaction
checking of safety contact and diode

010370 ZE 0: output 3 measuring system defect X70:19 O-75.4 E 1


no crane operation possible, entry in error list
replace central unit

010371 ZE 0: output 3 short circuit to ground or transistor defect X70:19 O-75.4 E 1


no crane operation possible, entry in error list
check lines, replace central unit

010372 ZE 0: output 3 outside source feeding X70:19 O-75.4 E 1


no crane operation possible, entry in error list
check lines

010373 ZE 0: output 3 open circuit or short circuit to supply voltage/ground X70:19 O-75.4 E 1
entry in error list
re-start, check lines

010470 ZE 0: output 4 measuring system defect X70:20 E 1


no crane operation possible, entry in error list
replace central unit

010471 ZE 0: output 4 short circuit to ground or transistor defect X70:20 E 1


no crane operation possible, entry in error list
check lines, replace central unit

002389508 9
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

010472 ZE 0: output 4 outside source feeding X70:20 E 1


no crane operation possible, entry in error list
check lines

010473 ZE 0: output 4 open circuit or short circuit to supply voltage/ground X70:20 E 1


entry in error list
re-start, check lines

010560 ZE 0: output 5 safety chain error, diode defect or safety contact sticking X70:21 O-75.5 E 1
report of error, otherwise no reaction
checking of safety contact and diode

010570 ZE 0: output 5 measuring system defect X70:21 O-75.5 E 1


no crane operation possible, entry in error list
replace central unit

010571 ZE 0: output 5 short circuit to ground or transistor defect X70:21 O-75.5 E 1


no crane operation possible, entry in error list
check lines, replace central unit

010572 ZE 0: output 5 outside source feeding X70:21 O-75.5 E 1


no crane operation possible, entry in error list
check lines

010573 ZE 0: output 5 open circuit or short circuit to supply voltage/ground X70:21 O-75.5 E 1
entry in error list
re-start, check lines

010660 ZE 0: output 6 safety chain error, diode defect or safety contact sticking X70:22 O-75.3 E 1
report of error, otherwise no reaction
checking of safety contact and diode

010670 ZE 0: output 6 measuring system defect X70:22 O-75.3 E 1


no crane operation possible, entry in error list
replace central unit

010671 ZE 0: output 6 short circuit to ground or transistor defect X70:22 O-75.3 E 1


no crane operation possible, entry in error list
check lines, replace central unit

002389508 10
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

010672 ZE 0: output 6 outside source feeding X70:22 O-75.3 E 1


no crane operation possible, entry in error list
check lines

010673 ZE 0: output 6 open circuit or short circuit to supply voltage/ground X70:22 O-75.3 E 1
entry in error list
re-start, check lines

010760 ZE 0: output 7 safety chain error, diode defect or safety contact sticking X70:23 O-75.1 E 1
report of error, otherwise no reaction
checking of safety contact and diode

010770 ZE 0: output 7 measuring system defect X70:23 O-75.1 E 1


no crane operation possible, entry in error list
replace central unit

010771 ZE 0: output 7 short circuit to ground or transistor defect X70:23 O-75.1 E 1


no crane operation possible, entry in error list
check lines, replace central unit

010772 ZE 0: output 7 outside source feeding X70:23 O-75.1 E 1


no crane operation possible, entry in error list
check lines

010773 ZE 0: output 7 open circuit or short circuit to supply voltage/ground X70:23 O-75.1 E 1
entry in error list
re-start, check lines

014959 ZE 0: all output supply voltage missing X70 E 1


no crane operation possible, entry in error list

015059 ZE 0: output group 0 supply voltage missing X70:12 O-42.1 E 1


no crane operation possible, entry in error list

015159 ZE 0: output group 1 supply voltage missing X70:24 O-42.2 E 1


no crane operation possible, entry in error list

002389508 11
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

015259 ZE 0: output group 2 supply voltage missing X70:25 E 1


no crane operation possible, entry in error list

015359 ZE 0: output group 3 supply voltage missing X70:13 E 1


no crane operation possible, entry in error list

020050 ZE 0: LSB participant address 0 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

020051 ZE 0: LSB participant address 0 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

020053 ZE 0: LSB participant address 0 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

020054 ZE 0: LSB participant address 0 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

020064 ZE 0: LSB participant address 0 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

020065 ZE 0: LSB participant address 0 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

020066 ZE 0: LSB participant address 0 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

020067 ZE 0: LSB participant address 0 supports no download function X635:z14/z16 O-52.4/52.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

002389508 12
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

020150 ZE 0: LSB participant address 1 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

020151 ZE 0: LSB participant address 1 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

020153 ZE 0: LSB participant address 1 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

020154 ZE 0: LSB participant address 1 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

020164 ZE 0: LSB participant address 1 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

020165 ZE 0: LSB participant address 1 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

020166 ZE 0: LSB participant address 1 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

020167 ZE 0: LSB participant address 1 supports no download function X635:z14/z16 O-52.4/52.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

020250 ZE 0: LSB participant address 2 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

020251 ZE 0: LSB participant address 2 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

002389508 13
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

020253 ZE 0: LSB participant address 2 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

020254 ZE 0: LSB participant address 2 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

020263 ZE 0: LSB participant address 2 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

020264 ZE 0: LSB participant address 2 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

020265 ZE 0: LSB participant address 2 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

020266 ZE 0: LSB participant address 2 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

020267 ZE 0: LSB participant address 2 supports no download function X635:z14/z16 O-52.4/52.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

020350 ZE 0: LSB participant address 3 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

020351 ZE 0: LSB participant address 3 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

020353 ZE 0: LSB participant address 3 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

002389508 14
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

020354 ZE 0: LSB participant address 3 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

020363 ZE 0: LSB participant address 3 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

020364 ZE 0: LSB participant address 3 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

020365 ZE 0: LSB participant address 3 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

020366 ZE 0: LSB participant address 3 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

020367 ZE 0: LSB participant address 3 supports no download function X635:z14/z16 O-52.4/52.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

020450 ZE 0: LSB participant address 4 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

020451 ZE 0: LSB participant address 4 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

020453 ZE 0: LSB participant address 4 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

020454 ZE 0: LSB participant address 4 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

002389508 15
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

020463 ZE 0: LSB participant address 4 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

020464 ZE 0: LSB participant address 4 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

020465 ZE 0: LSB participant address 4 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

020466 ZE 0: LSB participant address 4 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

020467 ZE 0: LSB participant address 4 supports no download function X635:z14/z16 O-52.4/52.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

020550 ZE 0: LSB participant address 5 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

020551 ZE 0: LSB participant address 5 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

020553 ZE 0: LSB participant address 5 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

020554 ZE 0: LSB participant address 5 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

020563 ZE 0: LSB participant address 5 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

002389508 16
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

020564 ZE 0: LSB participant address 5 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

020565 ZE 0: LSB participant address 5 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

020566 ZE 0: LSB participant address 5 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

020567 ZE 0: LSB participant address 5 supports no download function X635:z14/z16 O-52.4/52.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

020650 ZE 0: LSB participant address 6 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

020651 ZE 0: LSB participant address 6 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

020653 ZE 0: LSB participant address 6 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

020654 ZE 0: LSB participant address 6 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

020663 ZE 0: LSB participant address 6 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

020664 ZE 0: LSB participant address 6 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

002389508 17
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

020665 ZE 0: LSB participant address 6 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

020666 ZE 0: LSB participant address 6 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

020667 ZE 0: LSB participant address 6 supports no download function X635:z14/z16 O-52.4/52.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

021004 ZE 0: LSB participant address 10 level exceeded X635:z14/z16 O-52.4/52.4 E 1


report of error, otherwise no reaction
check sensor installation and pre-attenuation of sensor, clear clogged sensor, if defect replace sensor

021005 ZE 0: LSB participant address 10 below minimum level X635:z14/z16 O-52.4/52.4 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

021018 ZE 0: LSB participant address 10 excess temperature X635:z14/z16 O-52.4/52.4 E 1


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

021050 ZE 0: LSB participant address 10 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

021051 ZE 0: LSB participant address 10 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

021053 ZE 0: LSB participant address 10 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

021054 ZE 0: LSB participant address 10 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

002389508 18
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

021063 ZE 0: LSB participant address 10 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

021064 ZE 0: LSB participant address 10 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

021065 ZE 0: LSB participant address 10 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

021066 ZE 0: LSB participant address 10 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

021067 ZE 0: LSB participant address 10 supports no download function X635:z14/z16 O-52.4/52.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

021104 ZE 0: LSB participant address 11 level exceeded X635:z14/z16 O-52.4/52.4 E 1


report of error, otherwise no reaction
check sensor installation and pre-attenuation of sensor, clear clogged sensor, if defect replace sensor

021105 ZE 0: LSB participant address 11 below minimum level X635:z14/z16 O-52.4/52.4 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

021118 ZE 0: LSB participant address 11 excess temperature X635:z14/z16 O-52.4/52.4 E 1


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

021150 ZE 0: LSB participant address 11 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

021151 ZE 0: LSB participant address 11 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

002389508 19
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

021153 ZE 0: LSB participant address 11 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

021154 ZE 0: LSB participant address 11 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

021163 ZE 0: LSB participant address 11 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

021164 ZE 0: LSB participant address 11 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

021165 ZE 0: LSB participant address 11 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

021166 ZE 0: LSB participant address 11 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

021167 ZE 0: LSB participant address 11 supports no download function X635:z14/z16 O-52.4/52.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

022150 ZE 0: LSB participant address 21 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

022151 ZE 0: LSB participant address 21 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

022153 ZE 0: LSB participant address 21 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

002389508 20
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

022154 ZE 0: LSB participant address 21 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

022163 ZE 0: LSB participant address 21 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

022164 ZE 0: LSB participant address 21 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

022165 ZE 0: LSB participant address 21 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

022166 ZE 0: LSB participant address 21 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

022167 ZE 0: LSB participant address 21 supports no download function X635:z14/z16 O-52.4/52.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

022250 ZE 0: LSB participant address 22 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

022251 ZE 0: LSB participant address 22 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

022253 ZE 0: LSB participant address 22 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

022254 ZE 0: LSB participant address 22 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

002389508 21
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

022263 ZE 0: LSB participant address 22 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

022264 ZE 0: LSB participant address 22 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

022265 ZE 0: LSB participant address 22 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

022266 ZE 0: LSB participant address 22 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

022267 ZE 0: LSB participant address 22 supports no download function X635:z14/z16 O-52.4/52.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

022350 ZE 0: LSB participant address 23 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

022351 ZE 0: LSB participant address 23 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

022353 ZE 0: LSB participant address 23 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

022354 ZE 0: LSB participant address 23 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

022363 ZE 0: LSB participant address 23 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

002389508 22
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

022364 ZE 0: LSB participant address 23 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

022365 ZE 0: LSB participant address 23 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

022366 ZE 0: LSB participant address 23 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

022367 ZE 0: LSB participant address 23 supports no download function X635:z14/z16 O-52.4/52.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

022450 ZE 0: LSB participant address 24 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

022451 ZE 0: LSB participant address 24 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

022453 ZE 0: LSB participant address 24 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

022454 ZE 0: LSB participant address 24 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

022463 ZE 0: LSB participant address 24 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

022464 ZE 0: LSB participant address 24 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

002389508 23
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

022465 ZE 0: LSB participant address 24 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

022466 ZE 0: LSB participant address 24 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

022467 ZE 0: LSB participant address 24 supports no download function X635:z14/z16 O-52.4/52.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

022550 ZE 0: LSB participant address 25 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

022551 ZE 0: LSB participant address 25 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

022553 ZE 0: LSB participant address 25 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

022554 ZE 0: LSB participant address 25 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

022563 ZE 0: LSB participant address 25 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

022564 ZE 0: LSB participant address 25 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

022565 ZE 0: LSB participant address 25 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

002389508 24
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

022566 ZE 0: LSB participant address 25 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

022567 ZE 0: LSB participant address 25 supports no download function X635:z14/z16 O-52.4/52.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

023206 ZE 0: Control data transfer LSB line connection to participant disrupted/not plugged in X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check bus connections, if connections OK despite error then check sensor and replace if necessary

023252 ZE 0: Control data transfer LSB has recognised Bus collisions, communication interrupted X635:z14/z16 O-52.4/52.4 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor

023255 ZE 0: Control data transfer LSB Bus connection faulty/defect, short circuit to supply voltage X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

023256 ZE 0: Control data transfer LSB Bus connection faulty/defect, no supply/short circuit to earth X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

023257 ZE 0: Control data transfer LSB has recognised network re-set (data transfer starts again) X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part

023258 ZE 0: Control data transfer LSB recognised participant with incorrect baud rate in bus X635:z14/z16 O-52.4/52.4 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors

023259 ZE 0: Control data transfer LSB recognised communication breakdown in bus X635:z14/z16 O-52.4/52.4 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network

023260 ZE 0: Control data transfer LSB driver error: no order to carry out X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software

002389508 25
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

023261 ZE 0: Control data transfer LSB driver error: undefined message appears X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination

023262 ZE 0: Control data transfer LSB driver error: initialising error X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination

024814 ZE 0: input 0 short circuit to supply voltage X635:d2 O-51.5 E 1


output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board

024856 ZE 0: input 0 open circuit or short circuit to ground X635:d2 O-51.5 E 1


output of error, shut-down through application
check supply, LICCON input, sensor line for breaks , defect sensor through withdrawing of sensor

025014 ZE 0: input 2 short circuit to supply voltage X635:d6 O-91.1 E 1


output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board

025056 ZE 0: input 2 open circuit or short circuit to ground X635:d6 O-91.1 E 1


output of error, shut-down through application
check supply, LICCON input, sensor line for breaks , defect sensor through withdrawing of sensor

025102 ZE 0: input 3 sensor deficiency data short circuit to supply voltage X635:d8 E 1
report of error, otherwise no reaction
check supply, LICCON input, sensor lines to short or break, sensor

025202 ZE 0: input 4 sensor deficiency data short circuit to supply voltage X635:d10 E 1
report of error, otherwise no reaction
check supply, LICCON input, sensor lines to short or break, sensor

025210 ZE 0: input 4 inadmissable signal difference X635:d10 E 1


Output of error, due to defective feedback signal slewing platform locking no selection of corresponding table poss.
check supply, LICCON input, sensor lines to short or break, sensor

027210 ZE 0: input 24 inadmissable signal difference X635:b18 O-83.2 E 1


Output of error, due to defective feedback signal slewing platform locking no selection of corresponding table poss.
check supply, LICCON input, sensor lines to short or break, sensor

002389508 26
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

030000 ZE 0: LMB crane not commissioned or memory error B 1


error report only
program commissioning data according to commissioning report through after-sales service

030005 ZE 0: LMB winch 1 not regulated, hook course indicator erroneous E 1


imprecise winch control and incorrect hook course indication for winch 1
trigger adjustment switch for hook course indication of winch 1 through lowering

030006 ZE 0: LMB winch 2 not regulated, hook course indicator erroneous E 1


imprecise winch control and incorrect hook course indication of winch 2
trigger adjustment switch for hook course indication of winch 2 through lowering

030007 ZE 0: LMB winch 3 not regulated, hook course indicator erroneous E 1


imprecise winch control and incorrect hook course indication of winch 3
trigger adjustment switch for hook course indication of winch 3 through lowering

030040 ZE 0: LMB no standard table defined for this crane B 3


program stop
install new data memory card with corrected charts

030041 ZE 0: LMB all data for actual operation mode not available B 3
program stop
install new data memory card with corrected charts

030042 ZE 0: LMB no valid control word in this table B 3


program stop
install new data memory card with corrected charts

030050 ZE 0: LMB no load chart displayed B 1


acoustical signal on actuation of OK-key, no modification in operation program
select valid load chart through short-code or function keys F2-F6 and confirm with ENTER

030051 ZE 0: LMB external information (e.g. slewing platform bolting) missing B 1


load chart cannot be entered through OK-key
activate slewing platform lock, if necessary check connection to end of stroke switch, or select another load chart

030052 ZE 0: LMB re-fitting with load more than 0.5t and utilization larger 20% B 1
load chart cannot be entered through OK-key
put load to ground or switch crane off and on again

002389508 27
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

030053 ZE 0: LMB MAN-/AUTO-change-over blocked, unbolt cylinder/tele selected, MS B 1


switch-over on manual operation prevented as cylinder or tele not pinned
approach pre-selected telescoping target in automatic operation mode (bolt cylinder or tele)

030054 ZE 0: LMB no new telescoping objective, cylinder/tele unbolting selected, MS B 1


telesc.target modification prevented, switch cylinder/tele bolting to "0" position, MS deflected "telesc."
switch over switch to "0" position and release MS "telescoping"

030059 ZE 0: LMB length sensor defect at bolting time, tele-length invalid E 1


actual tele length is rejected, LMB-Stop
retract boom completely and operate telescoping cylinder into last telescopic section

030064 ZE 0: LMB measured overall torque smaller than half torque without charge B 2
LMB-Stop: Load torque increasing movements cannot be affected
move boom out of danger zone or check sensor (angle-, pressure-, length),if load or radius indication incorrect

030065 ZE 0: LMB computation-bound program part will no longer run B 2


LMB-Stop: Load torque increasing movements cannot be affected
on starting, the set-up equipment program key was pressed

030067 ZE 0: LMB STOP, difference between length sensors 1 and 2 too great B 2
LMB-Stop: Load torque increasing movements cannot be affected
set the correct length sensors zero point

030079 ZE 0: LMB STOP, adjusted op. mode and crane configuration not identical B 2
LMB-Stop: Load torque increasing movements cannot be affected
set up crane according to selected operation mode

030110 ZE 0: LMB STOP, tipping danger at rear; no telescoping and no luffing B 2


load torque reducing movements (telescoping in, luffing up) cannot de affected
take care when luffing down to chart area while assembly mode selected

030120 ZE 0: LMB STOP, end of stroke switch 1 in tele-operation not connected E 2


LMB-Stop: Load torque increasing movements cannot be affected
connect end of stroke switch 1, or check limit switch or supply line

030121 ZE 0: LMB STOP, end of stroke switch 1 reports internal error E 2


LMB-Stop: Load torque increasing movements cannot be affected
replace end of stroke switch 1

002389508 28
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

030122 ZE 0: LMB STOP, end of stroke switch 2 in auxiliary boom op. not connected E 2
LMB-Stop: Load torque increasing movements cannot be affected
connect end of stroke switch 2, or check limit switch or supply line

030123 ZE 0: LMB STOP, end of stroke switch 2 reports internal error E 2


LMB-Stop: Load torque increasing movements cannot be affected
replace end of stroke switch 2

030124 ZE 0: LMB STOP, end of stroke switch 3 in auxiliary boom op. not connected E 2
LMB-Stop: Load torque increasing movements cannot be affected
connect end of stroke switch 3, or check limit switch or supply line

030125 ZE 0: LMB STOP, end of stroke switch 3 reports internal error E 2


LMB-Stop: Load torque increasing movements cannot be affected
replace end of stroke switch 3

030130 ZE 0: LMB STOP, hoist limit switch 4 with 2 winch device not connected B

030131 ZE 0: LMB STOP, hoist limit switch 4 reports internal error B

030135 ZE 0: LMB permissible deviation of data A/B tension meas. bracket 1 exceeded E 2
LMB-Stop: Load torque increasing movements cannot be affected
check connecting brackets or power supply, different stress flow into both connecting brackets possible

030136 ZE 0: LMB permissible deviation of data A/B tension meas. bracket 2 exceeded E 2
LMB-Stop: Load torque increasing movements cannot be affected
check connecting brackets or power supply, different stress flow into both connecting brackets possible

030137 ZE 0: LMB permissible deviation of data A/B tension meas. bracket 3 exceeded E 2
LMB-Stop: Load torque increasing movements cannot be affected
check connecting brackets or power supply, different stress flow into both connecting brackets possible

030147 ZE 0: LMB working radius list in load chart with incorrect value B 2
LMB-Stop: Load torque increasing movements cannot be affected
install new data memory card with corrected charts

002389508 29
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

030148 ZE 0: LMB actual working radius too small, not in chart B 2


LMB-Stop: Load torque increasing movements cannot be affected
take care when luffing down to chart area while assembly mode selected

030149 ZE 0: LMB actual working radius too large, not in chart B 2


LMB-Stop: Load torque increasing movements cannot be affected
take care with "luffing up when overloaded" when luffing up into chart area

030150 ZE 0: LMB crane stands in impermissible length-/angle position B 2


LMB-Stop: Load torque increasing movements cannot be affected
conduct boom in permissible position referred to length, boom angle, bolting condition and fly jib angle

030151 ZE 0: LMB unknown access type to load chart B 2


LMB-Stop: Load torque increasing movements cannot be affected
install new data memory card with corrected charts

030152 ZE 0: LMB no table exists for actual crane configuration B 2


LMB-Stop: Load torque increasing movements cannot be affected
purchase additional load charts, install new data memory card with corrected charts

030153 ZE 0: LMB selected attachment config. not corresponding with actual condition B 2
LMB-Stop: Load torque increasing movements cannot be affected
select load chart corresponding to actual crane configuration

030154 ZE 0: LMB crane improperly supported or support pressure sensor defect B 2


LMB-Stop: Increased load torque movements and slewing cannot be affected
support crane so that the wheels are lifted from ground or check support pressure sensor or its lines

030155 ZE 0: LMB selected ballast not corresponding with actual condition B 2


LMB-Stop: Increased load torque movements and slewing cannot be affected
select chart that corresponds to the applied counterweight

030156 ZE 0: LMB selected support not corresponding with actual condition B 2


LMB-Stop: Load torque increasing movements, selected chart cannot be entered
enter chart that corresponds to the actual support condition

030157 ZE 0: LMB selected slewing range not corresponding with actual condition B 2
LMB-Stop: Load torque increasing movements cannot be affected
enter chart that corresponds to the actual slewing range

002389508 30
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

030163 ZE 0: LMB left/right pressure sensors not the same E 2


LMB-Stop: Load torque increasing movements cannot be affected
check pressure sensor or its line

030165 ZE 0: LMB difference between upper/lower angle sensor tele too great E 2
LMB-Stop: Load torque increasing movements cannot be affected
retrieve crane deflection through unloading, or check both angle sensors or their lines

030182 ZE 0: LMB difference between angle sensor cylinder lower/upper too great E 2
LMB-Stop: Load torque increasing movements cannot be affected
retrieve crane deflection through unloading, or check both angle sensors or their lines

030185 ZE 0: LMB actual ballast different from set ballast B 2


LMB-Stop: Load torque increasing movements cannot be affected
enter chart according to mounted counterweight

030186 ZE 0: LMB actual support different from support set B 2


LMB-Stop: Load torque increasing movements cannot be affected
enter chart according to adjusted support basis

030187 ZE 0: LMB actual slewing range different from set slewing range B 2
LMB-Stop: Load torque increasing movements cannot be affected
enter chart according to actual slewing angle of the boom

030190 ZE 0: LMB angle sensor error: load, reach, pulley head height indication defect E 2
LMB-Stop: Load torque increasing movements cannot be affected
check LSB-connection, angle sensor

030200 ZE 0: LMB STOP, crane correspondent table over-equipped B 2


control-Stop: even in operation mode crane movements cannot be affected
enter chart according to mounted equipment

030254 ZE 0: LMB STOP, miscalculation in interpolation (X1=X2) E 2


LMB-Stop: Load torque increasing movements cannot be affected
install new data memory card with corrected charts

032800 ZE 0: control slewing No swing movement recognised with selected swing gear E 1

002389508 31
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

033941 ZE 0: crane control Emergency operation switched on, Caution shut-downs ineffective B

034313 ZE 0: instruments armrest left master switch 2X both dir. contacts standing by simultaneously E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board

034315 ZE 0: instruments armrest left master switch 2X directional contact without zero contact E 1
output of error, shut-down through application
check supply, LICCON input, sensor lines for breaks , check defect sensor

034317 ZE 0: instruments armrest left master switch 2X analogue signal short to supply voltage E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board

034321 ZE 0: instruments armrest left master switch 2X analogue sig. open circuit or short to ground E 1
output of error, shut-down through application
check supply, LICCON input, sensor line for breaks , defect sensor through withdrawing of sensor

034800 ZE 0: control diagnosis system slewing sensor defective/missing E 1


Carrying out of test program delayed / interrupted
Check rotary encoder and connection, carry out test program again

034801 ZE 0: control diagnosis system tele angle sensor defective/missing E 1


Carrying out of test program delayed / interrupted
Check angle transmitter and connection, carry out test program again

034805 ZE 0: control diagnosis system longitudinal sensor defective/missing E 1


Carrying out of test program delayed / interrupted
Check length indicator and connection, carry out test program again

034810 ZE 0: control diagnosis system Rotary encoder value(s) implausible E 1


Carrying out of test program delayed / interrupted
Check rotary encoder / incremental sensor

034825 ZE 0: control diagnosis system charge pressure in slewing gear defective/missing E 1


Carrying out of test program delayed / interrupted
Check pressure hoist gear, carry out test program again

002389508 32
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

034833 ZE 0: control diagnosis system Pressure cut-off swing gear outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure hoist gear, carry out test program again

034856 ZE 0: control diagnosis system slewing gear turning with closed brakes E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

034857 ZE 0: control diagnosis system Initial current swing gear right above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

034858 ZE 0: control diagnosis system Initial current swing gear right below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

034859 ZE 0: control diagnosis system Initial current swing gear left above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

034860 ZE 0: control diagnosis system Initial current swing gear left below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

034861 ZE 0: control diagnosis system slewing speed right slewing gear too low E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

034862 ZE 0: control diagnosis system slewing speed right slewing gear too high E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

034863 ZE 0: control diagnosis system slewing speed left slewing gear too low E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

034864 ZE 0: control diagnosis system slewing speed left slewing gear too high E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

002389508 33
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

034865 ZE 0: control diagnosis system Hysteresis right-hand swing gear too great E 1
Carrying out of test program delayed / interrupted
Check proportional-flow valve

034866 ZE 0: control diagnosis system Hysteresis left-hand swing gear too great E 1
Carrying out of test program delayed / interrupted
Check proportional-flow valve

035808 ZE 0: operation slewing shut-down slewing right working area limitation ABB B

035809 ZE 0: operation slewing shut-down slewing left working area limitation ABB B

035819 ZE 0: operation slewing no or invalid operation mode shut-down B

035820 ZE 0: operation slewing shut-down slewing right LMB B

035821 ZE 0: operation slewing shut-down slewing left LMB B

035822 ZE 0: operation slewing Shut-down right-hand swing maximum load exceeded B

035823 ZE 0: operation slewing Shut-down left-hand swing maximum load exceeded B

035831 ZE 0: operation slewing Master switch 2 faulty/not present B

002389508 34
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

035839 ZE 0: operation slewing seat contact shut-down B

035890 ZE 0: operation slewing Slewing platform not bolted or impermissible bolting condition B 1
report of error, otherwise no reaction
Correct bolting position, check position ok: -supply, -input LICCON, -sensor line for short-circuit, -sensor

037049 ZE 0: operation instruments crane operators cab seat contact not activated, crane movements blocked B 1
output of error, shut-down through application
sit down (seat limit switch) or dead man (in master switch) or check LICCON input, sensor lines, sensor

037313 ZE 0: operation instruments armrest left master switch 2X not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor

039800 ZE 0: operation diagnosis system interruption, master switch defective or incorrectly deflected B 1
Carrying out of test program delayed / interrupted
Note direction of movements, carry out test program again

039801 ZE 0: operation diagnosis system interruption, master switch defective/missing B 1


Carrying out of test program delayed / interrupted
Check master switch, carry out test program again

039802 ZE 0: operation diagnosis system interruption, incorrect or no operation mode B 1


Carrying out of test program delayed / interrupted
Set correct operation type, if necessary dismantle accessory, carry out test program again

039803 ZE 0: operation diagnosis system Break, incorrect/faulty bolting condition swing gear B 1
Carrying out of test program delayed / interrupted
Unbolt slewing platform or check swing signals

039814 ZE 0: operation diagnosis system Alignment aid not correctly shut down B 1
Invalid operation condition, no proper crane operation possible
Apply F key, end active test program

039820 ZE 0: operation diagnosis system interruption, boom angle beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct luffing position, carry out test program again

002389508 35
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

039821 ZE 0: operation diagnosis system interruption, tele length beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct telescopic boom length length, carry out test program again

039822 ZE 0: operation diagnosis system interruption, hook load beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Note max. hook load, carry out test program again

039824 ZE 0: operation diagnosis system interruption, end of stroke switch activated/defective/missing B 1


Carrying out of test program delayed / interrupted
Check hoist limit switch, carry out test program again

100001 ZE 1: system error OS-HC11 (observe parameters) initialising error processor-register erroneous E 2
no crane operation possible
check program memory card or ZE

100002 ZE 1: system error OS-HC11 (observe parameters) initialising error test total in EPROM/FLASH erroneous E 2
no crane operation possible

100006 ZE 1: system error OS-HC11 (observe parameters) initialising error RAM erroneous E 2
no crane operation possible
with regular occurrence --> replace ZE

100007 ZE 1: system error OS-HC11 (observe parameters) UART erroneous E 2


no crane operation possible

100010 ZE 1: system error OS-HC11 (observe parameters) system routine inaccessible E 2


entry in error memory, all crane movements will be stopped
check ZE

100011 ZE 1: system error OS-HC11 (observe parameters) ZE-watchdog expired E 2


entry in error memory, all crane movements will be stopped
check program memory card

100012 ZE 1: system error OS-HC11 (observe parameters) type-identification in EPROM erroneous E 2


entry in error memory, no crane operation possible
check program memory card

002389508 36
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

100013 ZE 1: system error OS-HC11 (observe parameters) test total in EPROM/FLASH erroneous E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

100014 ZE 1: system error OS-HC11 (observe parameters) program already running E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

100015 ZE 1: system error OS-HC11 (observe parameters) program not available E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

100016 ZE 1: system error OS-HC11 (observe parameters) system-, driver-watchdog expired E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

100017 ZE 1: system error OS-HC11 (observe parameters) total of CPU-time distribution too great E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

100018 ZE 1: system error OS-HC11 (observe parameters) arithmetic overflow (16 Bit) E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

100019 ZE 1: system error OS-HC11 (observe parameters) division through zero (16 Bit) E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

100020 ZE 1: system error OS-HC11 (observe parameters) task-watchdog expired E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

100021 ZE 1: system error OS-HC11 (observe parameters) illegal opcode trap E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

100022 ZE 1: system error OS-HC11 (observe parameters) task inactive E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

002389508 37
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

100023 ZE 1: system error OS-HC11 (observe parameters) program incapable of running (type identification) E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

100024 ZE 1: system error OS-HC11 (observe parameters) task already used E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

100025 ZE 1: system error OS-HC11 (observe parameters) realtime-module already used E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

100026 ZE 1: system error OS-HC11 (observe parameters) regulator-module already used E 2


entry in error memory, all crane movements will be stopped

100030 ZE 1: system error OS-HC11 (observe parameters) unacceptable bank address E 2


entry in error memory, all crane movements will be stopped

100041 ZE 1: system error OS-HC11 (observe parameters) arithmetic error E 2


entry in error memory, all crane movements will be stopped

100044 ZE 1: system error OS-HC11 (observe parameters) output parameter without effect, from inactive output E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

100045 ZE 1: system error OS-HC11 (observe parameters) entry parameter undefined, from inactive input E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

100046 ZE 1: system error OS-HC11 (observe parameters) impermissible regulator parameter E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

100047 ZE 1: system error OS-HC11 (observe parameters) realtime-control block not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

002389508 38
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

100048 ZE 1: system error OS-HC11 (observe parameters) realtime-control block inactive E 2


entry in error memory, all crane movements will be stopped
check ZE

100049 ZE 1: system error OS-HC11 (observe parameters) urgent modul, ZE not available E 2
entry in error memory, no crane operation possible
with regular occurrence --> notify after-sales service

100050 ZE 1: system error OS-HC11 (observe parameters) file not available E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

100051 ZE 1: system error OS-HC11 (observe parameters) file already opened E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

100052 ZE 1: system error OS-HC11 (observe parameters) file not open on close E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

100053 ZE 1: system error OS-HC11 (observe parameters) system mask not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

100054 ZE 1: system error OS-HC11 (observe parameters) system text not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

100055 ZE 1: system error OS-HC11 (observe parameters) symbol not available E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

100056 ZE 1: system error OS-HC11 (observe parameters) invalid mark in symbol E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

100057 ZE 1: system error OS-HC11 (observe parameters) default load chart missing E 2
entry in error memory, all crane movements will be stopped
check wiring

002389508 39
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

100058 ZE 1: system error OS-HC11 (observe parameters) amplifier erroneous or return power feed E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

100059 ZE 1: system error OS-HC11 (observe parameters) subroutine not reenterant E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

100060 ZE 1: system error OS-HC11 (observe parameters) transmission error SCI E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

100061 ZE 1: system error OS-HC11 (observe parameters) SCI-BREAK E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

100062 ZE 1: system error OS-HC11 (observe parameters) SCI not connected E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

100063 ZE 1: system error OS-HC11 (observe parameters) monitor error in operation E 2


entry in error memory, all crane movements will be stopped

100065 ZE 1: system error OS-HC11 (observe parameters) impermissible bus address E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

100066 ZE 1: system error OS-HC11 (observe parameters) ADC working outside the permissible tolerance E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

100067 ZE 1: system error OS-HC11 (observe parameters) arithmetic processor not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

100068 ZE 1: system error OS-HC11 (observe parameters) impermissible interrupt E 2


entry in error memory, all crane movements will be stopped

002389508 40
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

100070 ZE 1: system error OS-HC11 (observe parameters) various structure versions E 2


entry in error memory, no crane operation possible
with regular occurrence --> replace ZE

100071 ZE 1: system error OS-HC11 (observe parameters) structure data missing E 2


entry in error memory, no crane operation possible
with regular occurrence --> replace ZE

100072 ZE 1: system error OS-HC11 (observe parameters) structure entry senseless E 2


entry in error memory, no crane operation possible
with regular occurrence --> replace ZE

100073 ZE 1: system error OS-HC11 (observe parameters) interpreter error E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

100074 ZE 1: system error OS-HC11 (observe parameters) transformation ASCII to BIN erroneous E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

100075 ZE 1: system error OS-HC11 (observe parameters) SPI-error E 2


entry in error memory, all crane movements will be stopped
check memory card in power supply unit

100076 ZE 1: system error OS-HC11 (observe parameters) incorrectly inserted power unit E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

100077 ZE 1: system error OS-HC11 (observe parameters) BAF-call-up erroneous E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

100078 ZE 1: system error OS-HC11 (observe parameters) impermissible parameter E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

100079 ZE 1: system error OS-HC11 (observe parameters) no right of access E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

002389508 41
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

100080 ZE 1: system error OS-HC11 (observe parameters) fatal internal software error E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

100081 ZE 1: system error OS-HC11 (observe parameters) stack overflow E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

100082 ZE 1: system error OS-HC11 (observe parameters) hardware-watchdog erroneous E 2


entry in error memory, all crane movements will be stopped

100094 ZE 1: system error OS-HC11 (observe parameters) transmission error parallel bus E 2
entry in error memory, all crane movements will be stopped

100095 ZE 1: system error OS-HC11 (observe parameters) DMA-error E 2


entry in error memory, all crane movements will be stopped

100099 ZE 1: system error OS-HC11 (observe parameters) TMS-error E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

102001 ZE 1: system error OS-TMS initialising error processor-register erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

102002 ZE 1: system error OS-TMS initialising error test total in EPROM/FLASH erroneous E 2
entry of error in error memory, all crane movements will be stopped
replace ZE

102006 ZE 1: system error OS-TMS initialising error RAM erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

102007 ZE 1: system error OS-TMS UART erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

002389508 42
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

102020 ZE 1: system error OS-TMS task-watchdog expired E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

102021 ZE 1: system error OS-TMS illegal opcode trap E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

102082 ZE 1: system error OS-TMS hardware-watchdog erroneous E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

110070 ZE 1: output 0 measuring system defect X71:16 O-70.3 E 1


no crane operation possible, entry in error list
replace central unit

110071 ZE 1: output 0 short circuit to ground or transistor defect X71:16 O-70.3 E 1


no crane operation possible, entry in error list
check lines, replace central unit

110072 ZE 1: output 0 outside source feeding X71:16 O-70.3 E 1


no crane operation possible, entry in error list
check lines

110073 ZE 1: output 0 open circuit or short circuit to supply voltage/ground X71:16 O-70.3 E 1
entry in error list
re-start, check lines

110170 ZE 1: output 1 measuring system defect X71:17 O-70.4 E 1


no crane operation possible, entry in error list
replace central unit

110171 ZE 1: output 1 short circuit to ground or transistor defect X71:17 O-70.4 E 1


no crane operation possible, entry in error list
check lines, replace central unit

110172 ZE 1: output 1 outside source feeding X71:17 O-70.4 E 1


no crane operation possible, entry in error list
check lines

002389508 43
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

110173 ZE 1: output 1 open circuit or short circuit to supply voltage/ground X71:17 O-70.4 E 1
entry in error list
re-start, check lines

110260 ZE 1: output 2 safety chain error, diode defect or safety contact sticking X71:18 O-69.6 E 1
report of error, otherwise no reaction
checking of safety contact and diode

110270 ZE 1: output 2 measuring system defect X71:18 O-69.6 E 1


no crane operation possible, entry in error list
replace central unit

110271 ZE 1: output 2 short circuit to ground or transistor defect X71:18 O-69.6 E 1


no crane operation possible, entry in error list
check lines, replace central unit

110272 ZE 1: output 2 outside source feeding X71:18 O-69.6 E 1


no crane operation possible, entry in error list
check lines

110273 ZE 1: output 2 open circuit or short circuit to supply voltage/ground X71:18 O-69.6 E 1
entry in error list
re-start, check lines

110360 ZE 1: output 3 safety chain error, diode defect or safety contact sticking X71:19 O-69.7 E 1
report of error, otherwise no reaction
checking of safety contact and diode

110370 ZE 1: output 3 measuring system defect X71:19 O-69.7 E 1


no crane operation possible, entry in error list
replace central unit

110371 ZE 1: output 3 short circuit to ground or transistor defect X71:19 O-69.7 E 1


no crane operation possible, entry in error list
check lines, replace central unit

110372 ZE 1: output 3 outside source feeding X71:19 O-69.7 E 1


no crane operation possible, entry in error list
check lines

002389508 44
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

110373 ZE 1: output 3 open circuit or short circuit to supply voltage/ground X71:19 O-69.7 E 1
entry in error list
re-start, check lines

110460 ZE 1: output 4 safety chain error, diode defect or safety contact sticking X71:20 O-64.5 E 1
report of error, otherwise no reaction
checking of safety contact and diode

110470 ZE 1: output 4 measuring system defect X71:20 O-64.5 E 1


no crane operation possible, entry in error list
replace central unit

110471 ZE 1: output 4 short circuit to ground or transistor defect X71:20 O-64.5 E 1


no crane operation possible, entry in error list
check lines, replace central unit

110472 ZE 1: output 4 outside source feeding X71:20 O-64.5 E 1


no crane operation possible, entry in error list
check lines

110473 ZE 1: output 4 open circuit or short circuit to supply voltage/ground X71:20 O-64.5 E 1
entry in error list
re-start, check lines

110560 ZE 1: output 5 safety chain error, diode defect or safety contact sticking X71:21 E 1
report of error, otherwise no reaction
checking of safety contact and diode

110570 ZE 1: output 5 measuring system defect X71:21 E 1


no crane operation possible, entry in error list
replace central unit

110571 ZE 1: output 5 short circuit to ground or transistor defect X71:21 E 1


no crane operation possible, entry in error list
check lines, replace central unit

110572 ZE 1: output 5 outside source feeding X71:21 E 1


no crane operation possible, entry in error list
check lines

002389508 45
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

110573 ZE 1: output 5 open circuit or short circuit to supply voltage/ground X71:21 E 1


entry in error list
re-start, check lines

110660 ZE 1: output 6 safety chain error, diode defect or safety contact sticking X71:22 O-69.5 E 1
report of error, otherwise no reaction
checking of safety contact and diode

110670 ZE 1: output 6 measuring system defect X71:22 O-69.5 E 1


no crane operation possible, entry in error list
replace central unit

110671 ZE 1: output 6 short circuit to ground or transistor defect X71:22 O-69.5 E 1


no crane operation possible, entry in error list
check lines, replace central unit

110672 ZE 1: output 6 outside source feeding X71:22 O-69.5 E 1


no crane operation possible, entry in error list
check lines

110673 ZE 1: output 6 open circuit or short circuit to supply voltage/ground X71:22 O-69.5 E 1
entry in error list
re-start, check lines

110760 ZE 1: output 7 safety chain error, diode defect or safety contact sticking X71:23 O-69.3 E 1
report of error, otherwise no reaction
checking of safety contact and diode

110770 ZE 1: output 7 measuring system defect X71:23 O-69.3 E 1


no crane operation possible, entry in error list
replace central unit

110771 ZE 1: output 7 short circuit to ground or transistor defect X71:23 O-69.3 E 1


no crane operation possible, entry in error list
check lines, replace central unit

110772 ZE 1: output 7 outside source feeding X71:23 O-69.3 E 1


no crane operation possible, entry in error list
check lines

002389508 46
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

110773 ZE 1: output 7 open circuit or short circuit to supply voltage/ground X71:23 O-69.3 E 1
entry in error list
re-start, check lines

114959 ZE 1: all output supply voltage missing X71 E 1


no crane operation possible, entry in error list

115059 ZE 1: output group 0 supply voltage missing X71:12 O-42.5 E 1


no crane operation possible, entry in error list

115159 ZE 1: output group 1 supply voltage missing X71:24 O-42.6 E 1


no crane operation possible, entry in error list

115259 ZE 1: output group 2 supply voltage missing X71:25 E 1


no crane operation possible, entry in error list

115359 ZE 1: output group 3 supply voltage missing X71:13 E 1


no crane operation possible, entry in error list

120050 ZE 1: LSB participant address 0 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

120051 ZE 1: LSB participant address 0 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

120053 ZE 1: LSB participant address 0 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

120054 ZE 1: LSB participant address 0 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

002389508 47
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

120064 ZE 1: LSB participant address 0 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

120065 ZE 1: LSB participant address 0 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

120066 ZE 1: LSB participant address 0 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

120067 ZE 1: LSB participant address 0 supports no download function X635A:z14/z16 O-53.4/53.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

120150 ZE 1: LSB participant address 1 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

120151 ZE 1: LSB participant address 1 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

120153 ZE 1: LSB participant address 1 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

120154 ZE 1: LSB participant address 1 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

120164 ZE 1: LSB participant address 1 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

120165 ZE 1: LSB participant address 1 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

002389508 48
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

120166 ZE 1: LSB participant address 1 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

120167 ZE 1: LSB participant address 1 supports no download function X635A:z14/z16 O-53.4/53.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

121004 ZE 1: LSB participant address 10 level exceeded X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
check sensor installation and pre-attenuation of sensor, clear clogged sensor, if defect replace sensor

121005 ZE 1: LSB participant address 10 below minimum level X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

121018 ZE 1: LSB participant address 10 excess temperature X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

121050 ZE 1: LSB participant address 10 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

121051 ZE 1: LSB participant address 10 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

121053 ZE 1: LSB participant address 10 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

121054 ZE 1: LSB participant address 10 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

121063 ZE 1: LSB participant address 10 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

002389508 49
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

121064 ZE 1: LSB participant address 10 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

121065 ZE 1: LSB participant address 10 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

121066 ZE 1: LSB participant address 10 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

121067 ZE 1: LSB participant address 10 supports no download function X635A:z14/z16 O-53.4/53.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

121104 ZE 1: LSB participant address 11 level exceeded X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
check sensor installation and pre-attenuation of sensor, clear clogged sensor, if defect replace sensor

121105 ZE 1: LSB participant address 11 below minimum level X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

121118 ZE 1: LSB participant address 11 excess temperature X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

121150 ZE 1: LSB participant address 11 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

121151 ZE 1: LSB participant address 11 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

121153 ZE 1: LSB participant address 11 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

002389508 50
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

121154 ZE 1: LSB participant address 11 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

121163 ZE 1: LSB participant address 11 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

121164 ZE 1: LSB participant address 11 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

121165 ZE 1: LSB participant address 11 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

121166 ZE 1: LSB participant address 11 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

121167 ZE 1: LSB participant address 11 supports no download function X635A:z14/z16 O-53.4/53.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

121204 ZE 1: LSB participant address 12 level exceeded X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
check sensor installation and pre-attenuation of sensor, clear clogged sensor, if defect replace sensor

121205 ZE 1: LSB participant address 12 below minimum level X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

121218 ZE 1: LSB participant address 12 excess temperature X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

121250 ZE 1: LSB participant address 12 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

002389508 51
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

121251 ZE 1: LSB participant address 12 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

121253 ZE 1: LSB participant address 12 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

121254 ZE 1: LSB participant address 12 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

121263 ZE 1: LSB participant address 12 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

121264 ZE 1: LSB participant address 12 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

121265 ZE 1: LSB participant address 12 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

121266 ZE 1: LSB participant address 12 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

121267 ZE 1: LSB participant address 12 supports no download function X635A:z14/z16 O-53.4/53.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

121304 ZE 1: LSB participant address 13 level exceeded X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
check sensor installation and pre-attenuation of sensor, clear clogged sensor, if defect replace sensor

121305 ZE 1: LSB participant address 13 below minimum level X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

002389508 52
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

121318 ZE 1: LSB participant address 13 excess temperature X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

121350 ZE 1: LSB participant address 13 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

121351 ZE 1: LSB participant address 13 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

121353 ZE 1: LSB participant address 13 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

121354 ZE 1: LSB participant address 13 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

121363 ZE 1: LSB participant address 13 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

121364 ZE 1: LSB participant address 13 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

121365 ZE 1: LSB participant address 13 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

121366 ZE 1: LSB participant address 13 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

121367 ZE 1: LSB participant address 13 supports no download function X635A:z14/z16 O-53.4/53.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

002389508 53
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

121404 ZE 1: LSB participant address 14 level exceeded X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
check sensor installation and pre-attenuation of sensor, clear clogged sensor, if defect replace sensor

121405 ZE 1: LSB participant address 14 below minimum level X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

121418 ZE 1: LSB participant address 14 excess temperature X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

121450 ZE 1: LSB participant address 14 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

121451 ZE 1: LSB participant address 14 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

121453 ZE 1: LSB participant address 14 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

121454 ZE 1: LSB participant address 14 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

121463 ZE 1: LSB participant address 14 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

121464 ZE 1: LSB participant address 14 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

121465 ZE 1: LSB participant address 14 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

002389508 54
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

121466 ZE 1: LSB participant address 14 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

121467 ZE 1: LSB participant address 14 supports no download function X635A:z14/z16 O-53.4/53.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

121604 ZE 1: LSB participant address 16 level exceeded X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
check sensor installation and pre-attenuation of sensor, clear clogged sensor, if defect replace sensor

121605 ZE 1: LSB participant address 16 below minimum level X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

121618 ZE 1: LSB participant address 16 excess temperature X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

121650 ZE 1: LSB participant address 16 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

121651 ZE 1: LSB participant address 16 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

121653 ZE 1: LSB participant address 16 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

121654 ZE 1: LSB participant address 16 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

121663 ZE 1: LSB participant address 16 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

002389508 55
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

121664 ZE 1: LSB participant address 16 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

121665 ZE 1: LSB participant address 16 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

121666 ZE 1: LSB participant address 16 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

121667 ZE 1: LSB participant address 16 supports no download function X635A:z14/z16 O-53.4/53.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

121704 ZE 1: LSB participant address 17 level exceeded X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
check sensor installation and pre-attenuation of sensor, clear clogged sensor, if defect replace sensor

121705 ZE 1: LSB participant address 17 below minimum level X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

121718 ZE 1: LSB participant address 17 excess temperature X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

121750 ZE 1: LSB participant address 17 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

121751 ZE 1: LSB participant address 17 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

121753 ZE 1: LSB participant address 17 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

002389508 56
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

121754 ZE 1: LSB participant address 17 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

121763 ZE 1: LSB participant address 17 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

121764 ZE 1: LSB participant address 17 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

121765 ZE 1: LSB participant address 17 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

121766 ZE 1: LSB participant address 17 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

121767 ZE 1: LSB participant address 17 supports no download function X635A:z14/z16 O-53.4/53.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

121804 ZE 1: LSB participant address 18 level exceeded X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
check sensor installation and pre-attenuation of sensor, clear clogged sensor, if defect replace sensor

121805 ZE 1: LSB participant address 18 below minimum level X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

121818 ZE 1: LSB participant address 18 excess temperature X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

121850 ZE 1: LSB participant address 18 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

002389508 57
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

121851 ZE 1: LSB participant address 18 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

121853 ZE 1: LSB participant address 18 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

121854 ZE 1: LSB participant address 18 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

121863 ZE 1: LSB participant address 18 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

121864 ZE 1: LSB participant address 18 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

121865 ZE 1: LSB participant address 18 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

121866 ZE 1: LSB participant address 18 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

121867 ZE 1: LSB participant address 18 supports no download function X635A:z14/z16 O-53.4/53.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

121904 ZE 1: LSB participant address 19 level exceeded X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
check sensor installation and pre-attenuation of sensor, clear clogged sensor, if defect replace sensor

121905 ZE 1: LSB participant address 19 below minimum level X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

002389508 58
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

121918 ZE 1: LSB participant address 19 excess temperature X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

121950 ZE 1: LSB participant address 19 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

121951 ZE 1: LSB participant address 19 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

121953 ZE 1: LSB participant address 19 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

121954 ZE 1: LSB participant address 19 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

121963 ZE 1: LSB participant address 19 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

121964 ZE 1: LSB participant address 19 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

121965 ZE 1: LSB participant address 19 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

121966 ZE 1: LSB participant address 19 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

121967 ZE 1: LSB participant address 19 supports no download function X635A:z14/z16 O-53.4/53.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

002389508 59
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

122004 ZE 1: LSB participant address 20 level exceeded X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
check sensor installation and pre-attenuation of sensor, clear clogged sensor, if defect replace sensor

122005 ZE 1: LSB participant address 20 below minimum level X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

122018 ZE 1: LSB participant address 20 excess temperature X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

122050 ZE 1: LSB participant address 20 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

122051 ZE 1: LSB participant address 20 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

122053 ZE 1: LSB participant address 20 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

122054 ZE 1: LSB participant address 20 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

122063 ZE 1: LSB participant address 20 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

122064 ZE 1: LSB participant address 20 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

122065 ZE 1: LSB participant address 20 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

002389508 60
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

122066 ZE 1: LSB participant address 20 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

122067 ZE 1: LSB participant address 20 supports no download function X635A:z14/z16 O-53.4/53.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

122104 ZE 1: LSB participant address 21 level exceeded X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
check sensor installation and pre-attenuation of sensor, clear clogged sensor, if defect replace sensor

122105 ZE 1: LSB participant address 21 below minimum level X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
check sensor installation, eliminate clogging or damage to sensor, if defect replace sensor

122118 ZE 1: LSB participant address 21 excess temperature X635A:z14/z16 O-53.4/53.4 E 1


report of error, otherwise no reaction
operate sensor in permitted temperature range, check sensor heat supply and carry off

122150 ZE 1: LSB participant address 21 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

122151 ZE 1: LSB participant address 21 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

122153 ZE 1: LSB participant address 21 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

122154 ZE 1: LSB participant address 21 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

122163 ZE 1: LSB participant address 21 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

002389508 61
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

122164 ZE 1: LSB participant address 21 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

122165 ZE 1: LSB participant address 21 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

122166 ZE 1: LSB participant address 21 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

122167 ZE 1: LSB participant address 21 supports no download function X635A:z14/z16 O-53.4/53.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

122950 ZE 1: LSB participant address 29 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

122951 ZE 1: LSB participant address 29 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

122953 ZE 1: LSB participant address 29 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

122954 ZE 1: LSB participant address 29 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

122963 ZE 1: LSB participant address 29 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

122964 ZE 1: LSB participant address 29 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

002389508 62
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

122965 ZE 1: LSB participant address 29 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

122966 ZE 1: LSB participant address 29 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

122967 ZE 1: LSB participant address 29 supports no download function X635A:z14/z16 O-53.4/53.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

123050 ZE 1: LSB participant address 30 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

123051 ZE 1: LSB participant address 30 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

123053 ZE 1: LSB participant address 30 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

123054 ZE 1: LSB participant address 30 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

123063 ZE 1: LSB participant address 30 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

123064 ZE 1: LSB participant address 30 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

123065 ZE 1: LSB participant address 30 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

002389508 63
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

123066 ZE 1: LSB participant address 30 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

123067 ZE 1: LSB participant address 30 supports no download function X635A:z14/z16 O-53.4/53.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

123206 ZE 1: Control data transfer LSB line connection to participant disrupted/not plugged in X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check bus connections, if connections OK despite error then check sensor and replace if necessary

123252 ZE 1: Control data transfer LSB has recognised Bus collisions, communication interrupted X635A:z14/z16 O-53.4/53.4 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor

123255 ZE 1: Control data transfer LSB Bus connection faulty/defect, short circuit to supply voltage X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

123256 ZE 1: Control data transfer LSB Bus connection faulty/defect, no supply/short circuit to earth X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

123257 ZE 1: Control data transfer LSB has recognised network re-set (data transfer starts again) X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part

123258 ZE 1: Control data transfer LSB recognised participant with incorrect baud rate in bus X635A:z14/z16 O-53.4/53.4 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors

123259 ZE 1: Control data transfer LSB recognised communication breakdown in bus X635A:z14/z16 O-53.4/53.4 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network

123260 ZE 1: Control data transfer LSB driver error: no order to carry out X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software

002389508 64
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

123261 ZE 1: Control data transfer LSB driver error: undefined message appears X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination

123262 ZE 1: Control data transfer LSB driver error: initialising error X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination

130570 ZE 1: remote control emergency operation telescoping movement selected with LICCON B 1

130571 ZE 1: remote control telescoping movement selected in manual operation B 1

130572 ZE 1: remote control selection with 2-winch operation mode E 1


error report, telescoping prevented
check SW-configuration, check LICCON input radio control

130610 ZE 1: Data recorder Start: (still) no valid crane number entered E 1


Inspect in 10 sec. cycles
Write in coefficients incl. crane number in the NT in "CRANE COMMISSIONING " program (MO > AK)

130611 ZE 1: Data recorder Start: Crane number faulty (not 9 figures numerically) E 1
Data recorder software stops - no documentation possible!
Define crane number correctly (Sxxxxxxx.yyQ - KNFttt00vvrr.Q)

130620 ZE 1: Data recorder Init: Firmware version incorrect/faulty E 1


Has not yet been checked!

130621 ZE 1: Data recorder Init: ATA-card not initialised E 1


STATUS-error: Data recorder software stops - no documentation possible!
Initialise ATA card with PC-Software "LICCON Manager"

130622 ZE 1: Data recorder Init: ATA-card contains different crane number E 1


STATUS-error: Data recorder software stops - no documentation possible!
Use ATA card with correct crane number or newly initialised ATA card

002389508 65
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

130623 ZE 1: Data recorder Init: Format-File-Transfer faulty E 1


Repeat of Format-File transfers in 1 sec. cycles
If necessary correct types and country specific Format-File "Lnnttt01vvrr.Q" in EPROM 0

130630 ZE 1: Data recorder Transfer: Data transmission faulty E 1


Repeat of data transfers in 1 sec. cycles
If necessary check connection from LICCON system to data recorder

130631 ZE 1: Data recorder Transfer: CSM-protocol error E 1


Respective telegram is repeated max. 3x, then synchronise completely anew
If necessary check connection from LICCON system to data recorder

130632 ZE 1: Data recorder Transfer: Transmission error (CRC) E 1


Respective telegram is repeated max. 3x, then synchronise completely anew
If necessary check connection from LICCON system to data recorder

130633 ZE 1: Data recorder Transfer: STATUS-error E 1


Dependent upon STATUS in 1 sec. cycles synchronise anew or stop data recorder software
If necessary check connection from LICCON system to data recorder

130634 ZE 1: Data recorder Transfer: TAN-error E 1


Synchronise CSM protocol again completely
If necessary check connection from LICCON system to data recorder

130635 ZE 1: Data recorder Transfer: Writing error E 1


Synchronise CSM protocol again completely
If necessary check connection from LICCON-System to data recorder and ATA card

130636 ZE 1: Data recorder Transfer: No recorder data (SPS-Handshake) E 1


LICCON data recorder software tries again in 1 sec. cycles
Check function of SPS software

132650 ZE 1: control telescoping Tele recognition faulty, more than one track switch reporting active E 1

134000 ZE 1: instruments crane operators cab master switch 3Y both dir. contacts standing by simultaneously E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board

002389508 66
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

134002 ZE 1: instruments crane operators cab master switch 3Y directional contact without zero contact E 1
output of error, shut-down through application
check supply, LICCON input, sensor lines for breaks , check defect sensor

134004 ZE 1: instruments crane operators cab master switch 3Y analogue signal short to supply voltage E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board

134008 ZE 1: instruments crane operators cab master switch 3Y analogue signal open circuit or short to ground E 1
output of error, shut-down through application
check supply, LICCON input, sensor line for breaks , defect sensor through withdrawing of sensor

134201 ZE 1: instruments armrest right master switch 1X both dir. contacts standing by simultaneously E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board

134203 ZE 1: instruments armrest right master switch 1X directional contact without zero contact E 1
output of error, shut-down through application
check supply, LICCON input, sensor lines for breaks , check defect sensor

134205 ZE 1: instruments armrest right master switch 1X analogue signal short to supply voltage E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board

134209 ZE 1: instruments armrest right master switch 1X analogue sig. open circuit or short circ. to ground E 1
output of error, shut-down through application
check supply, LICCON input, sensor line for breaks , defect sensor through withdrawing of sensor

134312 ZE 1: instruments armrest left master switch 2Y both dir. contacts standing by simultaneously E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board

134314 ZE 1: instruments armrest left master switch 2Y directional contact without zero contact E 1
output of error, shut-down through application
check supply, LICCON input, sensor lines for breaks , check defect sensor

134316 ZE 1: instruments armrest left master switch 2Y analogue signal short to supply voltage E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board

002389508 67
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

134320 ZE 1: instruments armrest left master switch 2Y analogue sig. open circuit or short to ground E 1
output of error, shut-down through application
check supply, LICCON input, sensor line for breaks , defect sensor through withdrawing of sensor

134801 ZE 1: control diagnosis system tele angle sensor defective/missing E 1


Carrying out of test program delayed / interrupted
Check angle transmitter and connection, carry out test program again

134804 ZE 1: control diagnosis system end of stroke switch defective/missing E 1


Carrying out of test program delayed / interrupted
Check hoist limit switch, lower hoist gear, carry out test program again

134805 ZE 1: control diagnosis system longitudinal sensor defective/missing E 1


Carrying out of test program delayed / interrupted
Check length indicator and connection, carry out test program again

134834 ZE 1: control diagnosis system Pressure cut-off cylinder out outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure cylinder Off, carry out test program again

134835 ZE 1: control diagnosis system Pressure cut-off tele out outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure telescopic boom length Off, carry out test program again

134836 ZE 1: control diagnosis system Pressure cut-off cylinder in outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure cylinder On, carry out test program again

134837 ZE 1: control diagnosis system Pressure cut-off tele in outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure telescopic boom length On, carry out test program again

134877 ZE 1: control diagnosis system Initial current telescoping in above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

134878 ZE 1: control diagnosis system Initial current telescoping in below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

002389508 68
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

134879 ZE 1: control diagnosis system Initial current telescoping out above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

134880 ZE 1: control diagnosis system Initial current telescoping out below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

134881 ZE 1: control diagnosis system Speed telescoping in below permissible area E 1


Carrying out of test program delayed / interrupted
Check valve / pump / pressure

134882 ZE 1: control diagnosis system Speed telescoping in above permissible area E 1


Carrying out of test program delayed / interrupted
Check valve / pump / pressure

134883 ZE 1: control diagnosis system Speed telescoping out below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

134884 ZE 1: control diagnosis system Speed telescoping out above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

134885 ZE 1: control diagnosis system Hysteresis telescoping in outside of permissible area E 1


Carrying out of test program delayed / interrupted
Check proportional-flow valve

134886 ZE 1: control diagnosis system Hysteresis telescoping out outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check proportional-flow valve

135608 ZE 1: operation telescoping shut-down tele OUT main boom working area limitation ABB B

135609 ZE 1: operation telescoping shut-down tele IN main boom working area limitation ABB B

002389508 69
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

135619 ZE 1: operation telescoping no or invalid operation mode shut-down B

135620 ZE 1: operation telescoping LMB shut-down B

135621 ZE 1: operation telescoping shut-down release of extending LMB B

135622 ZE 1: operation telescoping shut-down tipping risk to rear B

135630 ZE 1: operation telescoping master switch 1 defective/missing B

135631 ZE 1: operation telescoping master switch 2 defective/missing B

135635 ZE 1: operation telescoping right foot tipping switch defective/missing B

135639 ZE 1: operation telescoping seat contact shut-down B

135640 ZE 1: operation telescoping length measurement shut-down defective/missing B

135649 ZE 1: operation telescoping Shut-down hoist limit switch 4 B

002389508 70
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

135650 ZE 1: operation telescoping end of stroke switch shut-down 1 B

135651 ZE 1: operation telescoping end of stroke switch shut-down 2 B

135652 ZE 1: operation telescoping end of stroke switch shut-down 3 B

135660 ZE 1: operation telescoping unbolting telescope not possible, cylinder is not bolted B

135661 ZE 1: operation telescoping unbolting telescope not possible, no LMB release B

135662 ZE 1: operation telescoping unbolting telescope/cylinder not possible, simultaneous selection B

135663 ZE 1: operation telescoping unbolting cylinder not possible, telescope is not bolted B

135664 ZE 1: operation telescoping unbolting cylinder not possible, automatic system adjusted B

135665 ZE 1: operation telescoping unbolting telescope not possible, automatic system adjusted B

135681 ZE 1: operation telescoping end of stroke switch 1 shut-down defective B

002389508 71
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

135682 ZE 1: operation telescoping end of stroke switch 2 shut-down defective B

135683 ZE 1: operation telescoping end of stroke switch 3 shut-down defective B

135689 ZE 1: operation telescoping Shut-down hoist limit switch 4 faulty B

135690 ZE 1: operation telescoping cylinder bolting is neither unpinned nor in a pivot section B

135691 ZE 1: operation telescoping telescope OUT/IN shut-down, cylinder is not pinned B

137049 ZE 1: operation instruments crane operators cab seat contact not activated, crane movements blocked B 1
output of error, shut-down through application
sit down (seat limit switch) or dead man (in master switch) or check LICCON input, sensor lines, sensor

137201 ZE 1: operation instruments armrest right master switch 1X not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor

137312 ZE 1: operation instruments armrest left master switch 2Y not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor

139800 ZE 1: operation diagnosis system interruption, master switch defective or incorrectly deflected B 1
Carrying out of test program delayed / interrupted
Note direction of movements, carry out test program again

139801 ZE 1: operation diagnosis system interruption, master switch defective/missing B 1


Carrying out of test program delayed / interrupted
Check master switch, carry out test program again

002389508 72
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

139802 ZE 1: operation diagnosis system interruption, incorrect or no operation mode B 1


Carrying out of test program delayed / interrupted
Set correct operation type, if necessary dismantle accessory, carry out test program again

139804 ZE 1: operation diagnosis system Termination, change-over luff/telescoping incorrect switch position B 1
Carrying out of test program delayed / interrupted
Turn change-over luff./ tele. to correctly corresponding switch pos. ,erase error, actuate Reset and start again

139810 ZE 1: operation diagnosis system Termination, winch blocked B 1


Carrying out of test program delayed / interrupted
Disconnect winch, carry out test program again

139812 ZE 1: operation diagnosis system Termination, windable rope length too short B 1
Carrying out of test program delayed / interrupted
Check reeving wind off more rope, carry out test program again

139814 ZE 1: operation diagnosis system Alignment aid not correctly shut down B 1
Invalid operation condition, no proper crane operation possible
Apply F key, end active test program

139815 ZE 1: operation diagnosis system Switch over telescoping to operation type "Manual" B 1
Carrying out of test program delayed / interrupted
Change over to manual operation telescoping, erase error, actuate Reset and start again

139820 ZE 1: operation diagnosis system interruption, boom angle beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct luffing position, carry out test program again

139821 ZE 1: operation diagnosis system interruption, tele length beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct telescopic boom length length, carry out test program again

139822 ZE 1: operation diagnosis system interruption, hook load beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Note max. hook load, carry out test program again

139823 ZE 1: operation diagnosis system interruption, incorrect reeving B 1


Carrying out of test program delayed / interrupted
Note lowest amount of reevings, carry out test program again

002389508 73
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

139824 ZE 1: operation diagnosis system interruption, end of stroke switch activated/defective/missing B 1


Carrying out of test program delayed / interrupted
Check hoist limit switch, carry out test program again

139825 ZE 1: operation diagnosis system Termination, cylinder length outside of prescribed areas B 1
Carrying out of test program delayed / interrupted
Start up correct cylinder length (preferably with 100% bolted), carry out test program again

161001 E/A-Modul 1: system error OS-C167 initialising error processor-register erroneous E 2


error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

161002 E/A-Modul 1: system error OS-C167 initialising error test total in EPROM/FLASH erroneous E 2
error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

161006 E/A-Modul 1: system error OS-C167 initialising error RAM erroneous E 2


error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

161013 E/A-Modul 1: system error OS-C167 test total in EPROM/FLASH erroneous E 2


error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

161016 E/A-Modul 1: system error OS-C167 system-, driver-watchdog expired E 2


error indication on display
note error report, ignition On/Off, with regular occurrence --> notify after-sales service

161068 E/A-Modul 1: system error OS-C167 impermissible interrupt E 2


error indication on display
note error report, ignition On/Off, with regular occurrence --> notify after-sales service

161080 E/A-Modul 1: system error OS-C167 fatal internal software error E 2


error indication on display
note error report, ignition On/Off, with regular occurrence --> notify after-sales service

161082 E/A-Modul 1: system error OS-C167 hardware-watchdog erroneous E 2


error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

002389508 74
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

172052 E/A-Modul 1: input/output DEA0 output open, to low load, short circuit to supply voltage X613:17 U-72.2 E 3
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

172053 E/A-Modul 1: input/output DEA0 transistor current supply insufficient or missing X613:17 U-72.2 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

172054 E/A-Modul 1: input/output DEA0 short circuit to supply voltage X613:17 U-72.2 E 1
error report on display
check output for short, if necessary replace E/A-Modul

172055 E/A-Modul 1: input/output DEA0 excessive temperature, short circuit to ground or overload X613:17 U-72.2 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

172152 E/A-Modul 1: input/output DEA1 output open, to low load, short circuit to supply voltage X613:15 U-72.3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

172153 E/A-Modul 1: input/output DEA1 transistor current supply insufficient or missing X613:15 U-72.3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

172154 E/A-Modul 1: input/output DEA1 short circuit to supply voltage X613:15 U-72.3 E 1
error report on display
check output for short, if necessary replace E/A-Modul

172155 E/A-Modul 1: input/output DEA1 excessive temperature, short circuit to ground or overload X613:15 U-72.3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

172252 E/A-Modul 1: input/output DEA2 output open, to low load, short circuit to supply voltage X613:13 U-72.4 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

172253 E/A-Modul 1: input/output DEA2 transistor current supply insufficient or missing X613:13 U-72.4 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

002389508 75
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

172254 E/A-Modul 1: input/output DEA2 short circuit to supply voltage X613:13 U-72.4 E 1
error report on display
check output for short, if necessary replace E/A-Modul

172255 E/A-Modul 1: input/output DEA2 excessive temperature, short circuit to ground or overload X613:13 U-72.4 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

172352 E/A-Modul 1: input/output DEA3 output open, to low load, short circuit to supply voltage X613:11 U-72.5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

172353 E/A-Modul 1: input/output DEA3 transistor current supply insufficient or missing X613:11 U-72.5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

172354 E/A-Modul 1: input/output DEA3 short circuit to supply voltage X613:11 U-72.5 E 1
error report on display
check output for short, if necessary replace E/A-Modul

172355 E/A-Modul 1: input/output DEA3 excessive temperature, short circuit to ground or overload X613:11 U-72.5 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

172452 E/A-Modul 1: input/output DEA4 output open, to low load, short circuit to supply voltage X613:9 U-72.6 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

172453 E/A-Modul 1: input/output DEA4 transistor current supply insufficient or missing X613:9 U-72.6 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

172454 E/A-Modul 1: input/output DEA4 short circuit to supply voltage X613:9 U-72.6 E 1
error report on display
check output for short, if necessary replace E/A-Modul

172455 E/A-Modul 1: input/output DEA4 excessive temperature, short circuit to ground or overload X613:9 U-72.6 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

002389508 76
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

172552 E/A-Modul 1: input/output DEA5 output open, to low load, short circuit to supply voltage X613:7 U-72.6 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

172553 E/A-Modul 1: input/output DEA5 transistor current supply insufficient or missing X613:7 U-72.6 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

172554 E/A-Modul 1: input/output DEA5 short circuit to supply voltage X613:7 U-72.6 E 1
error report on display
check output for short, if necessary replace E/A-Modul

172555 E/A-Modul 1: input/output DEA5 excessive temperature, short circuit to ground or overload X613:7 U-72.6 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

172652 E/A-Modul 1: input/output DEA6 output open, to low load, short circuit to supply voltage X613:5 U-72.7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

172653 E/A-Modul 1: input/output DEA6 transistor current supply insufficient or missing X613:5 U-72.7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

172654 E/A-Modul 1: input/output DEA6 short circuit to supply voltage X613:5 U-72.7 E 1
error report on display
check output for short, if necessary replace E/A-Modul

172655 E/A-Modul 1: input/output DEA6 excessive temperature, short circuit to ground or overload X613:5 U-72.7 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

172752 E/A-Modul 1: input/output DEA7 output open, to low load, short circuit to supply voltage X613:3 U-72.8 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

172753 E/A-Modul 1: input/output DEA7 transistor current supply insufficient or missing X613:3 U-72.8 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

002389508 77
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

172754 E/A-Modul 1: input/output DEA7 short circuit to supply voltage X613:3 U-72.8 E 1
error report on display
check output for short, if necessary replace E/A-Modul

172755 E/A-Modul 1: input/output DEA7 excessive temperature, short circuit to ground or overload X613:3 U-72.8 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

173481 E/A-Modul 1: voltage input E4 short circuit to supply voltage, open line X612:9 U-67.3 E 1
symbol for brake pressure 1 is flashing on the display unit
check input signal on the E/A-Modul or sensor

173581 E/A-Modul 1: voltage input E5 short circuit to supply voltage, open line X612:7 U-67.2 E 1
symbol for brake pressure 2 is flashing on the display unit
check input signal on the E/A-Modul or sensor

173782 E/A-Modul 1: voltage input E7 short circuit to ground, open line, constant current 10 mA incorrect X612:4 U-53.6 E 1
no reaction
check input signal on the E/A-Modul or sensor

173783 E/A-Modul 1: voltage input E7 short circuit to supply voltage, open line, lack of voltage X612:4 U-53.6 E 1
no reaction
check input signal on the E/A-Modul or sensor

179052 E/A-Modul 1: output A0 output open, to low load, short circuit to supply voltage X613:18 U-62.5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

179053 E/A-Modul 1: output A0 transistor current supply insufficient or missing X613:18 U-62.5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

179054 E/A-Modul 1: output A0 short circuit to supply voltage X613:18 U-62.5 E 1


error report on display
check output for short, if necessary replace E/A-Modul

179055 E/A-Modul 1: output A0 excessive temperature, short circuit to ground or overload X613:18 U-62.5 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

002389508 78
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

179152 E/A-Modul 1: output A1 output open, to low load, short circuit to supply voltage X613:16 U-53.5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

179153 E/A-Modul 1: output A1 transistor current supply insufficient or missing X613:16 U-53.5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

179154 E/A-Modul 1: output A1 short circuit to supply voltage X613:16 U-53.5 E 1


error report on display
check output for short, if necessary replace E/A-Modul

179155 E/A-Modul 1: output A1 excessive temperature, short circuit to ground or overload X613:16 U-53.5 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

179250 E/A-Modul 1: bridge output A2 short circuit to ground, junction not supplied X613:14 U-82.8 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul

179251 E/A-Modul 1: bridge output A2 short circuit to supply voltage, excessive temperature X613:14 U-82.8 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul

179252 E/A-Modul 1: bridge output A2 output open, to low load, short circuit to supply voltage X613:14 U-82.8 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

179253 E/A-Modul 1: bridge output A2 transistor current supply insufficient or missing X613:14 U-82.8 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

179254 E/A-Modul 1: bridge output A2 short circuit to supply voltage X613:14 U-82.8 E 1
error report on display
check output for short, if necessary replace E/A-Modul

179255 E/A-Modul 1: bridge output A2 excessive temperature, short circuit to ground or overload X613:14 U-82.8 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

002389508 79
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

179350 E/A-Modul 1: bridge output A3 short circuit to ground, junction not supplied X613:12 U-73.2 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul

179351 E/A-Modul 1: bridge output A3 short circuit to supply voltage, excessive temperature X613:12 U-73.2 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul

179352 E/A-Modul 1: bridge output A3 output open, to low load, short circuit to supply voltage X613:12 U-73.2 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

179353 E/A-Modul 1: bridge output A3 transistor current supply insufficient or missing X613:12 U-73.2 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

179354 E/A-Modul 1: bridge output A3 short circuit to supply voltage X613:12 U-73.2 E 1
error report on display
check output for short, if necessary replace E/A-Modul

179355 E/A-Modul 1: bridge output A3 excessive temperature, short circuit to ground or overload X613:12 U-73.2 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

183401 E/A-Modul 1: SPI-control unit Faulty data transfer E/A-module<>unit (time exceeded) X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

183402 E/A-Modul 1: SPI-control unit Serious system error to SPI-connection (interface) X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

183403 E/A-Modul 1: SPI-control unit break in line or short circuit to supply voltage X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary

183404 E/A-Modul 1: SPI-control unit break in line or short circuit to ground X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary

002389508 80
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

183406 E/A-Modul 1: SPI-control unit Data transfer faulty (faulty check byte) X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
suppress EMV- interference

183407 E/A-Modul 1: SPI-control unit Unit faulty/missing, incorrect unit inserted (ID) X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
check periphery and replace if necessary, check Software version, check EMV- interference

183408 E/A-Modul 1: SPI-control unit Data transfer faulty (incorrect number of data bytes received) X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

183900 E/A-Modul 1: Control operating unit (SPI) Faulty initialisation data connection E/A-module<>unit X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

183902 E/A-Modul 1: Control operating unit (SPI) Serious system error to SPI-connection (interface) X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

183905 E/A-Modul 1: Control operating unit (SPI) Initialisation error, resetting inputs/outputs faulty X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
check wiring, check periphery and replace if necessary, check E/A-Modul and replace if necessary

183907 E/A-Modul 1: Control operating unit (SPI) Unit faulty/missing, incorrect unit inserted (ID) X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
connect functional periphery unit, system then eliminates error independently

183908 E/A-Modul 1: Control operating unit (SPI) Data transfer faulty (incorrect number of data bytes received) X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

184050 E/A-Modul 1: LSB-B participant address 0 reports an incorrect sensor type X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

184051 E/A-Modul 1: LSB-B participant address 0 was not configured for the block transfer X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

002389508 81
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

184053 E/A-Modul 1: LSB-B participant address 0 no longer reports or withdrawn during running period X613:4/6 U-46.3/46.2 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

184054 E/A-Modul 1: LSB-B participant address 0 Features other settings (parameters) as pre-entered set values X613:4/6 U-46.3/46.2 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

184064 E/A-Modul 1: LSB-B participant address 0 reports tolerable error in self-test X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

184065 E/A-Modul 1: LSB-B participant address 0 reports intolerable error in self-test X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

184066 E/A-Modul 1: LSB-B participant address 0 with software version, that is no longer compatible X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

184067 E/A-Modul 1: LSB-B participant address 0 supports no download function X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

184150 E/A-Modul 1: LSB-B participant address 1 reports an incorrect sensor type X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

184151 E/A-Modul 1: LSB-B participant address 1 was not configured for the block transfer X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

184153 E/A-Modul 1: LSB-B participant address 1 no longer reports or withdrawn during running period X613:4/6 U-46.3/46.2 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

184154 E/A-Modul 1: LSB-B participant address 1 Features other settings (parameters) as pre-entered set values X613:4/6 U-46.3/46.2 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

002389508 82
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

184164 E/A-Modul 1: LSB-B participant address 1 reports tolerable error in self-test X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

184165 E/A-Modul 1: LSB-B participant address 1 reports intolerable error in self-test X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

184166 E/A-Modul 1: LSB-B participant address 1 with software version, that is no longer compatible X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

184167 E/A-Modul 1: LSB-B participant address 1 supports no download function X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

184250 E/A-Modul 1: LSB-B participant address 2 reports an incorrect sensor type X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

184251 E/A-Modul 1: LSB-B participant address 2 was not configured for the block transfer X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

184253 E/A-Modul 1: LSB-B participant address 2 no longer reports or withdrawn during running period X613:4/6 U-46.3/46.2 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

184254 E/A-Modul 1: LSB-B participant address 2 Features other settings (parameters) as pre-entered set values X613:4/6 U-46.3/46.2 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

184264 E/A-Modul 1: LSB-B participant address 2 reports tolerable error in self-test X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

184265 E/A-Modul 1: LSB-B participant address 2 reports intolerable error in self-test X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

002389508 83
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

184266 E/A-Modul 1: LSB-B participant address 2 with software version, that is no longer compatible X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

184267 E/A-Modul 1: LSB-B participant address 2 supports no download function X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

184350 E/A-Modul 1: LSB-B participant address 3 reports an incorrect sensor type X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

184351 E/A-Modul 1: LSB-B participant address 3 was not configured for the block transfer X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

184353 E/A-Modul 1: LSB-B participant address 3 no longer reports or withdrawn during running period X613:4/6 U-46.3/46.2 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

184354 E/A-Modul 1: LSB-B participant address 3 Features other settings (parameters) as pre-entered set values X613:4/6 U-46.3/46.2 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

184364 E/A-Modul 1: LSB-B participant address 3 reports tolerable error in self-test X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

184365 E/A-Modul 1: LSB-B participant address 3 reports intolerable error in self-test X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

184366 E/A-Modul 1: LSB-B participant address 3 with software version, that is no longer compatible X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

184367 E/A-Modul 1: LSB-B participant address 3 supports no download function X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

002389508 84
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

184450 E/A-Modul 1: LSB-B participant address 4 reports an incorrect sensor type X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

184451 E/A-Modul 1: LSB-B participant address 4 was not configured for the block transfer X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

184453 E/A-Modul 1: LSB-B participant address 4 no longer reports or withdrawn during running period X613:4/6 U-46.3/46.2 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

184454 E/A-Modul 1: LSB-B participant address 4 Features other settings (parameters) as pre-entered set values X613:4/6 U-46.3/46.2 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

184464 E/A-Modul 1: LSB-B participant address 4 reports tolerable error in self-test X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

184465 E/A-Modul 1: LSB-B participant address 4 reports intolerable error in self-test X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

184466 E/A-Modul 1: LSB-B participant address 4 with software version, that is no longer compatible X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

184467 E/A-Modul 1: LSB-B participant address 4 supports no download function X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

184550 E/A-Modul 1: LSB-B participant address 5 reports an incorrect sensor type X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

184551 E/A-Modul 1: LSB-B participant address 5 was not configured for the block transfer X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

002389508 85
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

184553 E/A-Modul 1: LSB-B participant address 5 no longer reports or withdrawn during running period X613:4/6 U-46.3/46.2 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

184554 E/A-Modul 1: LSB-B participant address 5 Features other settings (parameters) as pre-entered set values X613:4/6 U-46.3/46.2 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

184564 E/A-Modul 1: LSB-B participant address 5 reports tolerable error in self-test X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

184565 E/A-Modul 1: LSB-B participant address 5 reports intolerable error in self-test X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

184566 E/A-Modul 1: LSB-B participant address 5 with software version, that is no longer compatible X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

184567 E/A-Modul 1: LSB-B participant address 5 supports no download function X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

184650 E/A-Modul 1: LSB-B participant address 6 reports an incorrect sensor type X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

184651 E/A-Modul 1: LSB-B participant address 6 was not configured for the block transfer X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

184653 E/A-Modul 1: LSB-B participant address 6 no longer reports or withdrawn during running period X613:4/6 U-46.3/46.2 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

184654 E/A-Modul 1: LSB-B participant address 6 Features other settings (parameters) as pre-entered set values X613:4/6 U-46.3/46.2 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

002389508 86
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

184664 E/A-Modul 1: LSB-B participant address 6 reports tolerable error in self-test X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

184665 E/A-Modul 1: LSB-B participant address 6 reports intolerable error in self-test X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

184666 E/A-Modul 1: LSB-B participant address 6 with software version, that is no longer compatible X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

184667 E/A-Modul 1: LSB-B participant address 6 supports no download function X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

187252 E/A-Modul 1: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X613:4/6 U-46.3/46.2 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor

187255 E/A-Modul 1: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X613:4/6 U-46.3/46.2 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

187256 E/A-Modul 1: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X613:4/6 U-46.3/46.2 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

187257 E/A-Modul 1: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X613:4/6 U-46.3/46.2 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part

187258 E/A-Modul 1: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X613:4/6 U-46.3/46.2 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors

187259 E/A-Modul 1: Control data transfer LSB-B recognised communication breakdown in bus X613:4/6 U-46.3/46.2 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network

002389508 87
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

187260 E/A-Modul 1: Control data transfer LSB-B driver error: no order to carry out X613:4/6 U-46.3/46.2 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software

187261 E/A-Modul 1: Control data transfer LSB-B driver error: undefined message appears X613:4/6 U-46.3/46.2 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination

187262 E/A-Modul 1: Control data transfer LSB-B driver error: initialising error X613:4/6 U-46.3/46.2 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination

187530 E/A-Modul 1: CAN-participant engine Data transfer subscriber transfer cycle exceeded X615:5/6 U-51.1/51.2 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul

187531 E/A-Modul 1: CAN-participant engine Data transfer faulty/missing, max. cycle time exceeded X615:5/6 U-51.1/51.2 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

187630 E/A-Modul 1: CAN-participant gear Data transfer subscriber transfer cycle exceeded X615:5/6 U-51.1/51.2 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

187631 E/A-Modul 1: CAN-participant gear Data transfer faulty/missing, max. cycle time exceeded X615:5/6 U-51.1/51.2 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

187730 E/A-Modul 1: CAN-participant ABV (ABS/ASR) Data transfer subscriber transfer cycle exceeded X615:5/6 U-51.1/51.2 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

187731 E/A-Modul 1: CAN-participant ABV (ABS/ASR) Data transfer faulty/missing, max. cycle time exceeded X615:5/6 U-51.1/51.2 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

188530 E/A-Modul 1: CAN-participant E/A-Modul 1 Data transfer subscriber transfer cycle exceeded X615:5/6 U-51.1/51.2 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

002389508 88
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

188531 E/A-Modul 1: CAN-participant E/A-Modul 1 Data transfer faulty/missing, max. cycle time exceeded X615:5/6 U-51.1/51.2 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

188930 E/A-Modul 1: CAN-participant E/A-Modul 5 Data transfer subscriber transfer cycle exceeded X615:5/6 U-51.1/51.2 E 1
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

188931 E/A-Modul 1: CAN-participant E/A-Modul 5 Data transfer faulty/missing, max. cycle time exceeded X615:5/6 U-51.1/51.2 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

189900 E/A-Modul 1: Control data transfer CAN internal error: register error CAN-controller X615:5/6 U-51.1/51.2 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul

189901 E/A-Modul 1: Control data transfer CAN internal error: RAM-error CAN-controller X615:5/6 U-51.1/51.2 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul

189902 E/A-Modul 1: Control data transfer CAN configuration error CAN-software X615:5/6 U-51.1/51.2 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul, check Software (test system ZE)

189903 E/A-Modul 1: Control data transfer CAN Transfer interrupted after continuous error X615:5/6 U-51.1/51.2 E 1
CAN-Transmission will be aborted
check bus lines/neutral point, replace neutral point or E/A-Modul

189910 E/A-Modul 1: Control data transfer CAN short-term error in bus connection X615:5/6 U-51.1/51.2 E 0
re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated

189911 E/A-Modul 1: Control data transfer CAN permanent error bus connection X615:5/6 U-51.1/51.2 E 1
cyclic re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated

189920 E/A-Modul 1: Control data transfer CAN active participant not responding X615:5/6 U-51.1/51.2 E 0
parameterised substitute values for receiver signals will be used
check error report for missing participant(s), test system ZE

002389508 89
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

189921 E/A-Modul 1: Control data transfer CAN No active subscriber responding X615:5/6 U-51.1/51.2 E 1
parameterised substitute values for receiver signals will be used
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul

189950 E/A-Modul 1: Control data transfer CAN erroneous command test system X615:5/6 U-51.1/51.2 E 1
no reaction to unknown test system control command in CAN-System Software
check Software (test system)

192001 E/A-Modul 1: control engine long-term disruption E/A-Modul <-> engine control E 1
engine control and E/A-Modul at emergency speed
engine control and E/A-Modul, check CAN-bus-connections

192110 E/A-Modul 1: control transmission long-term disruption shift selector operation unit <-> gears E 1
transmission control and E/A-Modul (operation unit) in emergency drive program
check transmission control and E/A-Modul, CAN-bus-connection

192111 E/A-Modul 1: control transmission long-term disruption shift selector crane op. cab<-> E/A-Modul E 1
after re-generation of the connection first "N" requirement
check LSB-connection ZE<>E/A-Modul, crane operators cab travel switch or connection to ZE (test system)

192112 E/A-Modul 1: control transmission long-term disruption connection E/A-Modul <-> operation unit E 1
transmission control and E/A-Modul (operation unit) in emergency drive program
check connection E/A-Modul<>operation unit, power supplies operation unit; replace E/A- Modul or operation unit

192113 E/A-Modul 1: control transmission error in shift selector keys operation unit: key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit

192114 E/A-Modul 1: control transmission shift selector operation unit: D key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit

192115 E/A-Modul 1: control transmission shift selector operation unit: N key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit

192116 E/A-Modul 1: control transmission shift selector operation unit: R key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit

002389508 90
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

192117 E/A-Modul 1: control transmission shift selector operation unit: gear+ key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit

192118 E/A-Modul 1: control transmission shift selector operation unit: gear- key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit

192119 E/A-Modul 1: control transmission shift selector operation unit: travel program key 1/2 sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit

192128 E/A-Modul 1: control transmission feedback of off-road gear simultaneously ON and OFF E 1
control system prevents disengagement of the off-road gear ON or OFF, remaining in actual position when ignition ON
check sensor for acknowledgement(s), check line connections to the E/A-Modul, replace E/A-Modul

193455 E/A-Modul 1: control lighting amperage indicator erroneous E 1


function is not carried out
use original incandescent lamps, check indicator system for short to supply voltage

193456 E/A-Modul 1: control lighting vehicle indicator defective E 1


function is not carried out
check indicator system

194190 E/A-Modul 1: LSB-bus participant ZE missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

194192 E/A-Modul 1: LSB-bus participant E/A-Modul 2 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

194193 E/A-Modul 1: LSB-bus participant E/A-Modul 3 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

194194 E/A-Modul 1: LSB-bus participant E/A-Modul 4 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

002389508 91
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

194195 E/A-Modul 1: LSB-bus participant E/A-Modul 5 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

194800 E/A-Modul 1: control diagnosis system error in diagnosis requirement CAN-participant engine E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants

194801 E/A-Modul 1: control diagnosis system error in diagnosis requirement CAN-participant gears E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants

194802 E/A-Modul 1: control diagnosis system error in diagnosis requirement CAN-participant ABS E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants

194810 E/A-Modul 1: control diagnosis system error in test system-diagnosis CAN-participant engine E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants

194811 E/A-Modul 1: control diagnosis system error in test system-diagnosis CAN-participant gears E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants

194812 E/A-Modul 1: control diagnosis system error in test system-diagnosis CAN-participant ABS E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants

195150 E/A-Modul 1: operation transmission gears in emergency shift selector operation B

195151 E/A-Modul 1: operation transmission CAN-connection shift selector <-> gear electronics malfunctioning B

195152 E/A-Modul 1: operation transmission connection shift selector <-> keyboard unit malfunctioning B

002389508 92
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

195153 E/A-Modul 1: operation transmission pre-selection not neutral/crane op. cab malfunction <-> E/A-Modul B

195154 E/A-Modul 1: operation transmission shift selector out of order: upper-carriage-operation mode B

195161 E/A-Modul 1: operation transmission shift selector out of order: key sticking B

195172 E/A-Modul 1: operation transmission selection of travel direction prevented, op. type not recognized B

195173 E/A-Modul 1: operation transmission selection of travel dir. prevented, multi-shift selector keys activ. B

195174 E/A-Modul 1: operation transmission shift selector out of order when engine OFF B

195175 E/A-Modul 1: operation transmission selection of travel dir. prevented, pre-selection in neutral only B

195176 E/A-Modul 1: operation transmission selection of travel direction prevented, operation brake not active B

195179 E/A-Modul 1: operation transmission pre-selection gear+ prevented, maximum gear attained B

195180 E/A-Modul 1: operation transmission pre-selection gear+ prevented, rear axle not locked B

002389508 93
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

195182 E/A-Modul 1: operation transmission pre-selection gear+/- prevented, gear in neutral B

195183 E/A-Modul 1: operation transmission pre-selection gear- prevented, minimum gear attained B

195190 E/A-Modul 1: operation transmission travel program change-over only possible in neutral B

195194 E/A-Modul 1: operation transmission selection of travel dir. prevented due to gear malf. "do not shift" B

195195 E/A-Modul 1: operation transmission pre-selection not neutral after gear malfunction "do not shift" B

195501 E/A-Modul 1: operation axle suspension operation of 2-hand-function without activation of 2-hand-key B
function is not carried out
activate both keys simultaneously or start test program of keyboard unit

195503 E/A-Modul 1: operation axle suspension operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)

195505 E/A-Modul 1: operation axle suspension operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode

195509 E/A-Modul 1: operation axle suspension unauthorised operation from under-carriage B


function is not carried out
start engine and repeat operation

195570 E/A-Modul 1: operation axle suspension undefined condition: neither blocked nor with suspension B
function is not carried out
check blocked limit switch and buffered limit switch

002389508 94
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

195571 E/A-Modul 1: operation axle suspension undefined condition: blocked and with suspension B
function is not carried out
check blocked limit switch and buffered limit switch

195601 E/A-Modul 1: operation level/filling/draining operation of 2-hand-function without activation of 2-hand-key B


function is not carried out
activate both keys simultaneously or start test program of keyboard unit

195603 E/A-Modul 1: operation level/filling/draining operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)

195605 E/A-Modul 1: operation level/filling/draining operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode

195609 E/A-Modul 1: operation level/filling/draining unauthorised operation from under-carriage B


function is not carried out
start engine and repeat operation

195640 E/A-Modul 1: operation level/filling/draining level with blocked axle suspension B


function is not carried out
switch axles to suspended condition

195641 E/A-Modul 1: operation level/filling/draining simultaneous filling and draining selected B


function is not carried out
select either filling or draining

195642 E/A-Modul 1: operation level/filling/draining no individual operation when level function is active B
function is not carried out
only activate level key

195643 E/A-Modul 1: operation level/filling/draining gears not in neutral B


function is not carried out
switch transmission to neutral (N)

195801 E/A-Modul 1: operation axle oscillitation operation of 2-hand-function without activation of 2-hand-key B
function is not carried out
activate both keys simultaneously or start test program of keyboard unit

002389508 95
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

195802 E/A-Modul 1: operation axle oscillitation operation from upper-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)

195803 E/A-Modul 1: operation axle oscillitation operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)

195804 E/A-Modul 1: operation axle oscillitation operation from upper-carriage with under-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode

195805 E/A-Modul 1: operation axle oscillitation operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode

195808 E/A-Modul 1: operation axle oscillitation unauthorised operation from upper-carriage B


function is not carried out
start engine and repeat operation

195809 E/A-Modul 1: operation axle oscillitation unauthorised operation from under-carriage B


function is not carried out
start engine and repeat operation

195821 E/A-Modul 1: operation axle oscillitation function not available in upper-carriage operation mode B
function is not carried out
on customers request

195822 E/A-Modul 1: operation axle oscillitation function not available in under-carriage operation mode B
function is not carried out
on customers request

195855 E/A-Modul 1: operation axle oscillitation selection from upper-carriage with axle not blocked B
function is not carried out
block axles

195856 E/A-Modul 1: operation axle oscillitation selection from under-carriage with axle not blocked B
function is not carried out
block axles

002389508 96
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

195857 E/A-Modul 1: operation axle oscillitation oscillation selection not permissible B


function is not carried out

195901 E/A-Modul 1: operation longitudinal lock operation of 2-hand-function without activation of 2-hand-key B
function is not carried out
activate both keys simultaneously or start test program of keyboard unit

195902 E/A-Modul 1: operation longitudinal lock operation from upper-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)

195903 E/A-Modul 1: operation longitudinal lock operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)

195904 E/A-Modul 1: operation longitudinal lock operation from upper-carriage with under-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode

195905 E/A-Modul 1: operation longitudinal lock operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode

195906 E/A-Modul 1: operation longitudinal lock operation from upper-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 4

195907 E/A-Modul 1: operation longitudinal lock operation from under-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 4

195908 E/A-Modul 1: operation longitudinal lock unauthorised operation from upper-carriage B


function is not carried out
start engine and repeat operation

195909 E/A-Modul 1: operation longitudinal lock unauthorised operation from under-carriage B


function is not carried out
start engine and repeat operation

002389508 97
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

195950 E/A-Modul 1: operation longitudinal lock feedback of off-road gear ON missing B


function is not carried out
check acknowledgement for off-road gear ON

195951 E/A-Modul 1: operation longitudinal lock off-road gear switched off B


function is not carried out
switch on off-road gear

196001 E/A-Modul 1: operation transversal lock operation of 2-hand-function without activation of 2-hand-key B
function is not carried out
activate both keys simultaneously or start test program of keyboard unit

196002 E/A-Modul 1: operation transversal lock operation from upper-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) on E/A-Modul 4, check LSB-connection (see electric circuit diagram)

196003 E/A-Modul 1: operation transversal lock operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) on E/A-Modul 4, check LSB-connection (see electric circuit diagram)

196004 E/A-Modul 1: operation transversal lock operation from upper-carriage with under-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode

196005 E/A-Modul 1: operation transversal lock operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode

196006 E/A-Modul 1: operation transversal lock operation from upper-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 4

196007 E/A-Modul 1: operation transversal lock operation from under-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 4

196008 E/A-Modul 1: operation transversal lock unauthorised operation from upper-carriage B


function is not carried out
start engine and repeat operation

002389508 98
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

196009 E/A-Modul 1: operation transversal lock unauthorised operation from under-carriage B


function is not carried out
start engine and repeat operation

196052 E/A-Modul 1: operation transversal lock selection of transversal lock ON with no longitudinal lock selected B
function is not carried out
acivate longitudinal locking

196100 E/A-Modul 1: operation unlocking rear axle function simultaneously ON and OFF B
function is not carried out
do not simultaneously activate contrasting function keys

196101 E/A-Modul 1: operation unlocking rear axle operation of 2-hand-function without activation of 2-hand-key B
function is not carried out
activate both keys simultaneously or start test program of keyboard unit

196102 E/A-Modul 1: operation unlocking rear axle operation from upper-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)

196103 E/A-Modul 1: operation unlocking rear axle operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)

196104 E/A-Modul 1: operation unlocking rear axle operation from upper-carriage with under-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode

196105 E/A-Modul 1: operation unlocking rear axle operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode

196106 E/A-Modul 1: operation unlocking rear axle operation from upper-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 4

196107 E/A-Modul 1: operation unlocking rear axle operation from under-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 4

002389508 99
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

196108 E/A-Modul 1: operation unlocking rear axle unauthorised operation from upper-carriage B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

196109 E/A-Modul 1: operation unlocking rear axle unauthorised operation from under-carriage B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

196111 E/A-Modul 1: operation unlocking rear axle unauthorised switching on of function B


function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

196112 E/A-Modul 1: operation unlocking rear axle unauthorised switching off of function B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

196113 E/A-Modul 1: operation unlocking rear axle unauthorised function activation B


function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

196114 E/A-Modul 1: operation unlocking rear axle activation of function without operation mode B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

196115 E/A-Modul 1: operation unlocking rear axle gear limit forwards exceeded with under-carriage operation mode B
function is not carried out
engage lower gear

196116 E/A-Modul 1: operation unlocking rear axle gear limit backwards exceeded with under-carriage operation mode B
function is not carried out
engage lower gear

196117 E/A-Modul 1: operation unlocking rear axle gear limit forwards exceeded with upper-carriage operation mode B
function is not carried out
engage lower gear

196118 E/A-Modul 1: operation unlocking rear axle gear limit backwards exceeded with upper-carriage operation mode B
function is not carried out
engage lower gear

002389508 100
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

196119 E/A-Modul 1: operation unlocking rear axle no direction with under-carriage operation mode B
function is not carried out
check CAN-connection and LSB-connection

196120 E/A-Modul 1: operation unlocking rear axle no direction with upper-carriage operation mode B
function is not carried out
check CAN-connection and LSB-connection

196160 E/A-Modul 1: operation unlocking rear axle undefined condition: simultaneously locked and unlocked B
function is not carried out
check unlocking condition, Check locking limit switch and unlocking limit switch

196200 E/A-Modul 1: operation steering rear axle function simultaneously ON and OFF B
function is not carried out
do not simultaneously activate contrasting function keys

196202 E/A-Modul 1: operation steering rear axle operation from upper-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)

196203 E/A-Modul 1: operation steering rear axle operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)

196204 E/A-Modul 1: operation steering rear axle operation from upper-carriage with under-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode

196205 E/A-Modul 1: operation steering rear axle operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode

196208 E/A-Modul 1: operation steering rear axle unauthorised operation from upper-carriage B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

196209 E/A-Modul 1: operation steering rear axle unauthorised operation from under-carriage B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

002389508 101
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

196263 E/A-Modul 1: operation steering rear axle no valid lock condition in upper-carriage operation mode B
function is not carried out
check unlocking condition, Check locking limit switch and unlocking limit switch

196264 E/A-Modul 1: operation steering rear axle no valid lock condition in under-carriage operation mode B
function is not carried out
check unlocking condition, Check locking limit switch and unlocking limit switch

196265 E/A-Modul 1: operation steering rear axle unauthorised steering selection in upper-carriage B
function is not carried out
steering only with rear axle unlocked, check LSB-connection

196266 E/A-Modul 1: operation steering rear axle unauthorised steering selection in under-carriage B
function is not carried out
steering only with rear axle unlocked, check LSB-connection

196570 E/A-Modul 1: operation brakes/pneumatics system upper-carriage parking brake only opened after signal CLOSE B

196700 E/A-Modul 1: operation off-road gear function simultaneously ON and OFF B


function is not carried out
do not simultaneously activate contrasting function keys

196703 E/A-Modul 1: operation off-road gear operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)

196704 E/A-Modul 1: operation off-road gear operation from upper-carriage with under-carriage operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)

196705 E/A-Modul 1: operation off-road gear operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode

196706 E/A-Modul 1: operation off-road gear operation from upper-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection in E/A-Modul 2

002389508 102
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

196707 E/A-Modul 1: operation off-road gear operation from under-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection in E/A-Modul 2

196775 E/A-Modul 1: operation off-road gear off-road gear and transfer box free in upper-carriage operation mode B
function is not carried out
do not disconnect transfer case in off-road gear ON or off-road gear not ON with disconnection of transfer gear

196776 E/A-Modul 1: operation off-road gear off-road gear and transfer box free in under-carriage operation mode B
function is not carried out
do not disconnect transfer case in off-road gear ON or off-road gear not ON with disconnection of transfer gear

196778 E/A-Modul 1: operation off-road gear speed too high for off-road gear B
function is not carried out
reduce speed

196779 E/A-Modul 1: operation off-road gear off-road gear ON and gears not neutral B
function is not carried out
switch transmission to neutral (N)

197030 E/A-Modul 1: operation heating/air.conditioning switching on air-conditioning only possible with engine running B
function is not carried out
start engine and repeat operation

197182 E/A-Modul 1: operation lighting indicator from upper-carriage in under-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode

197183 E/A-Modul 1: operation lighting indicator from under-carriage in upper-carriage operation mode B
function is not carried out
switch off undercarriage indicator

197184 E/A-Modul 1: operation lighting simultaneous left and right indicator B


function is not carried out
check steering column switch or wiring

197185 E/A-Modul 1: operation lighting hazard lights from upper-carriage and under-carriage B
function is not carried out
switch off warning light

002389508 103
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

197186 E/A-Modul 1: operation lighting rear fog lamp only with light B
function is not carried out
switch on full beam, dipped light or fog light

199890 E/A-Modul 1: operation diagnosis system test program not executable as engine is not OFF B
function prevented

199892 E/A-Modul 1: operation diagnosis system test program not executable as not in under-carriage op. mode B
function prevented

199893 E/A-Modul 1: operation diagnosis system function not available/no customisation B


function prevented

199895 E/A-Modul 1: operation diagnosis system start not possible as gears not in neutral B
function prevented

199896 E/A-Modul 1: operation diagnosis system function prevented/interrupted as parking brake is not locked B
carrying out of AEB-function only possible with closed parking brake
close parking brake, re-start function, then ignition off/on

199909 E/A-Modul 1: operation optional device unauthorised operation from under-carriage B


function is not carried out
start engine and repeat operation

199922 E/A-Modul 1: operation optional device function not available in under-carriage operation mode B
function is not carried out
on customers request

199924 E/A-Modul 1: operation optional device no customized function in under-carriage operation mode B
function is not carried out
on customers request

200001 ZE 2: system error OS-HC11 (observe parameters) initialising error processor-register erroneous E 2
no crane operation possible
with regular occurrence --> replace ZE

002389508 104
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

200002 ZE 2: system error OS-HC11 (observe parameters) initialising error test total in EPROM/FLASH erroneous E 2
no crane operation possible
check program memory card or ZE

200006 ZE 2: system error OS-HC11 (observe parameters) initialising error RAM erroneous E 2
no crane operation possible
with regular occurrence --> replace ZE

200007 ZE 2: system error OS-HC11 (observe parameters) UART erroneous E 2


no crane operation possible
with regular occurrence --> replace ZE

200010 ZE 2: system error OS-HC11 (observe parameters) system routine inaccessible E 2


entry in error memory, all crane movements will be stopped

200011 ZE 2: system error OS-HC11 (observe parameters) ZE-watchdog expired E 2


entry in error memory, all crane movements will be stopped
check ZE

200012 ZE 2: system error OS-HC11 (observe parameters) type-identification in EPROM erroneous E 2


entry in error memory, no crane operation possible
check program memory card

200013 ZE 2: system error OS-HC11 (observe parameters) test total in EPROM/FLASH erroneous E 2
entry in error memory, all crane movements will be stopped
check program memory card

200014 ZE 2: system error OS-HC11 (observe parameters) program already running E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200015 ZE 2: system error OS-HC11 (observe parameters) program not available E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200016 ZE 2: system error OS-HC11 (observe parameters) system-, driver-watchdog expired E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

002389508 105
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

200017 ZE 2: system error OS-HC11 (observe parameters) total of CPU-time distribution too great E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200018 ZE 2: system error OS-HC11 (observe parameters) arithmetic overflow (16 Bit) E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200019 ZE 2: system error OS-HC11 (observe parameters) division through zero (16 Bit) E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200020 ZE 2: system error OS-HC11 (observe parameters) task-watchdog expired E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200021 ZE 2: system error OS-HC11 (observe parameters) illegal opcode trap E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

200022 ZE 2: system error OS-HC11 (observe parameters) task inactive E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200023 ZE 2: system error OS-HC11 (observe parameters) program incapable of running (type identification) E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200024 ZE 2: system error OS-HC11 (observe parameters) task already used E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200025 ZE 2: system error OS-HC11 (observe parameters) realtime-module already used E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200026 ZE 2: system error OS-HC11 (observe parameters) regulator-module already used E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

002389508 106
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

200030 ZE 2: system error OS-HC11 (observe parameters) unacceptable bank address E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200041 ZE 2: system error OS-HC11 (observe parameters) arithmetic error E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200044 ZE 2: system error OS-HC11 (observe parameters) output parameter without effect, from inactive output E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200045 ZE 2: system error OS-HC11 (observe parameters) entry parameter undefined, from inactive input E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200046 ZE 2: system error OS-HC11 (observe parameters) impermissible regulator parameter E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200047 ZE 2: system error OS-HC11 (observe parameters) realtime-control block not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200048 ZE 2: system error OS-HC11 (observe parameters) realtime-control block inactive E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200049 ZE 2: system error OS-HC11 (observe parameters) urgent modul, ZE not available E 2
entry in error memory, no crane operation possible
check ZE

200050 ZE 2: system error OS-HC11 (observe parameters) file not available E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200051 ZE 2: system error OS-HC11 (observe parameters) file already opened E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

002389508 107
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

200052 ZE 2: system error OS-HC11 (observe parameters) file not open on close E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200053 ZE 2: system error OS-HC11 (observe parameters) system mask not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200054 ZE 2: system error OS-HC11 (observe parameters) system text not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200055 ZE 2: system error OS-HC11 (observe parameters) symbol not available E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200056 ZE 2: system error OS-HC11 (observe parameters) invalid mark in symbol E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200057 ZE 2: system error OS-HC11 (observe parameters) default load chart missing E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200058 ZE 2: system error OS-HC11 (observe parameters) amplifier erroneous or return power feed E 2
entry in error memory, all crane movements will be stopped
check wiring

200059 ZE 2: system error OS-HC11 (observe parameters) subroutine not reenterant E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service

200060 ZE 2: system error OS-HC11 (observe parameters) transmission error SCI E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

200061 ZE 2: system error OS-HC11 (observe parameters) SCI-BREAK E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

002389508 108
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

200062 ZE 2: system error OS-HC11 (observe parameters) SCI not connected E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

200063 ZE 2: system error OS-HC11 (observe parameters) monitor error in operation E 2


entry in error memory, all crane movements will be stopped
check monitor ZE and connection cable

200065 ZE 2: system error OS-HC11 (observe parameters) impermissible bus address E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

200066 ZE 2: system error OS-HC11 (observe parameters) ADC working outside the permissible tolerance E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

200067 ZE 2: system error OS-HC11 (observe parameters) arithmetic processor not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

200068 ZE 2: system error OS-HC11 (observe parameters) impermissible interrupt E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

200070 ZE 2: system error OS-HC11 (observe parameters) various structure versions E 2


entry in error memory, no crane operation possible
with regular occurrence --> replace ZE

200071 ZE 2: system error OS-HC11 (observe parameters) structure data missing E 2


entry in error memory, no crane operation possible
with regular occurrence --> replace ZE

200072 ZE 2: system error OS-HC11 (observe parameters) structure entry senseless E 2


entry in error memory, no crane operation possible
with regular occurrence --> replace ZE

200073 ZE 2: system error OS-HC11 (observe parameters) interpreter error E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

002389508 109
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

200074 ZE 2: system error OS-HC11 (observe parameters) transformation ASCII to BIN erroneous E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

200075 ZE 2: system error OS-HC11 (observe parameters) SPI-error E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

200076 ZE 2: system error OS-HC11 (observe parameters) incorrectly inserted power unit E 2
entry in error memory, all crane movements will be stopped
check memory card in power supply unit

200077 ZE 2: system error OS-HC11 (observe parameters) BAF-call-up erroneous E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

200078 ZE 2: system error OS-HC11 (observe parameters) impermissible parameter E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

200079 ZE 2: system error OS-HC11 (observe parameters) no right of access E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

200080 ZE 2: system error OS-HC11 (observe parameters) fatal internal software error E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

200081 ZE 2: system error OS-HC11 (observe parameters) stack overflow E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

200082 ZE 2: system error OS-HC11 (observe parameters) hardware-watchdog erroneous E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

200094 ZE 2: system error OS-HC11 (observe parameters) transmission error parallel bus E 2
entry in error memory, all crane movements will be stopped
check ZE, bus circuit board, power supply unit

002389508 110
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

200095 ZE 2: system error OS-HC11 (observe parameters) DMA-error E 2


entry in error memory, all crane movements will be stopped

200099 ZE 2: system error OS-HC11 (observe parameters) TMS-error E 2


entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE

202001 ZE 2: system error OS-TMS initialising error processor-register erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

202002 ZE 2: system error OS-TMS initialising error test total in EPROM/FLASH erroneous E 2
entry of error in error memory, all crane movements will be stopped
replace ZE

202006 ZE 2: system error OS-TMS initialising error RAM erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

202007 ZE 2: system error OS-TMS UART erroneous E 2


entry of error in error memory, all crane movements will be stopped
replace ZE

202020 ZE 2: system error OS-TMS task-watchdog expired E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

202021 ZE 2: system error OS-TMS illegal opcode trap E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

202082 ZE 2: system error OS-TMS hardware-watchdog erroneous E 2


entry of error in error memory, all crane movements will be stopped
elimination only possible through after-sales service

210060 ZE 2: output 0 safety chain error, diode defect or safety contact sticking X72:16 O-64.2 E 1
report of error, otherwise no reaction
checking of safety contact and diode

002389508 111
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

210070 ZE 2: output 0 measuring system defect X72:16 O-64.2 E 1


no crane operation possible, entry in error list
replace central unit

210071 ZE 2: output 0 short circuit to ground or transistor defect X72:16 O-64.2 E 1


no crane operation possible, entry in error list
check lines, replace central unit

210072 ZE 2: output 0 outside source feeding X72:16 O-64.2 E 1


no crane operation possible, entry in error list
check lines

210073 ZE 2: output 0 open circuit or short circuit to supply voltage/ground X72:16 O-64.2 E 1
entry in error list
re-start, check lines

210160 ZE 2: output 1 safety chain error, diode defect or safety contact sticking X72:17 O-64.3 E 1
report of error, otherwise no reaction
checking of safety contact and diode

210170 ZE 2: output 1 measuring system defect X72:17 O-64.3 E 1


no crane operation possible, entry in error list
replace central unit

210171 ZE 2: output 1 short circuit to ground or transistor defect X72:17 O-64.3 E 1


no crane operation possible, entry in error list
check lines, replace central unit

210172 ZE 2: output 1 outside source feeding X72:17 O-64.3 E 1


no crane operation possible, entry in error list
check lines

210173 ZE 2: output 1 open circuit or short circuit to supply voltage/ground X72:17 O-64.3 E 1
entry in error list
re-start, check lines

210260 ZE 2: output 2 safety chain error, diode defect or safety contact sticking X72:18 E 1
report of error, otherwise no reaction
checking of safety contact and diode

002389508 112
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

210270 ZE 2: output 2 measuring system defect X72:18 E 1


no crane operation possible, entry in error list
replace central unit

210271 ZE 2: output 2 short circuit to ground or transistor defect X72:18 E 1


no crane operation possible, entry in error list
check lines, replace central unit

210272 ZE 2: output 2 outside source feeding X72:18 E 1


no crane operation possible, entry in error list
check lines

210273 ZE 2: output 2 open circuit or short circuit to supply voltage/ground X72:18 E 1


entry in error list
re-start, check lines

210360 ZE 2: output 3 safety chain error, diode defect or safety contact sticking X72:19 E 1
report of error, otherwise no reaction
checking of safety contact and diode

210370 ZE 2: output 3 measuring system defect X72:19 E 1


no crane operation possible, entry in error list
replace central unit

210371 ZE 2: output 3 short circuit to ground or transistor defect X72:19 E 1


no crane operation possible, entry in error list
check lines, replace central unit

210372 ZE 2: output 3 outside source feeding X72:19 E 1


no crane operation possible, entry in error list
check lines

210373 ZE 2: output 3 open circuit or short circuit to supply voltage/ground X72:19 E 1


entry in error list
re-start, check lines

210460 ZE 2: output 4 safety chain error, diode defect or safety contact sticking X72:20 O-67.2 E 1
report of error, otherwise no reaction
checking of safety contact and diode

002389508 113
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

210470 ZE 2: output 4 measuring system defect X72:20 O-67.2 E 1


no crane operation possible, entry in error list
replace central unit

210471 ZE 2: output 4 short circuit to ground or transistor defect X72:20 O-67.2 E 1


no crane operation possible, entry in error list
check lines, replace central unit

210472 ZE 2: output 4 outside source feeding X72:20 O-67.2 E 1


no crane operation possible, entry in error list
check lines

210473 ZE 2: output 4 open circuit or short circuit to supply voltage/ground X72:20 O-67.2 E 1
entry in error list
re-start, check lines

210560 ZE 2: output 5 safety chain error, diode defect or safety contact sticking X72:21 O-67.4 E 1
report of error, otherwise no reaction
checking of safety contact and diode

210570 ZE 2: output 5 measuring system defect X72:21 O-67.4 E 1


no crane operation possible, entry in error list
replace central unit

210571 ZE 2: output 5 short circuit to ground or transistor defect X72:21 O-67.4 E 1


no crane operation possible, entry in error list
check lines, replace central unit

210572 ZE 2: output 5 outside source feeding X72:21 O-67.4 E 1


no crane operation possible, entry in error list
check lines

210573 ZE 2: output 5 open circuit or short circuit to supply voltage/ground X72:21 O-67.4 E 1
entry in error list
re-start, check lines

210670 ZE 2: output 6 measuring system defect X72:22 O-72.3 E 1


no crane operation possible, entry in error list
replace central unit

002389508 114
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

210671 ZE 2: output 6 short circuit to ground or transistor defect X72:22 O-72.3 E 1


no crane operation possible, entry in error list
check lines, replace central unit

210672 ZE 2: output 6 outside source feeding X72:22 O-72.3 E 1


no crane operation possible, entry in error list
check lines

210673 ZE 2: output 6 open circuit or short circuit to supply voltage/ground X72:22 O-72.3 E 1
entry in error list
re-start, check lines

210770 ZE 2: output 7 measuring system defect X72:23 O-72.5 E 1


no crane operation possible, entry in error list
replace central unit

210771 ZE 2: output 7 short circuit to ground or transistor defect X72:23 O-72.5 E 1


no crane operation possible, entry in error list
check lines, replace central unit

210772 ZE 2: output 7 outside source feeding X72:23 O-72.5 E 1


no crane operation possible, entry in error list
check lines

210773 ZE 2: output 7 open circuit or short circuit to supply voltage/ground X72:23 O-72.5 E 1
entry in error list
re-start, check lines

214959 ZE 2: all output supply voltage missing X72 E 1


no crane operation possible, entry in error list

215059 ZE 2: output group 0 supply voltage missing X72:12 O-43.1 E 1


no crane operation possible, entry in error list

215159 ZE 2: output group 1 supply voltage missing X72:24 O-43.2 E 1


no crane operation possible, entry in error list

002389508 115
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

215259 ZE 2: output group 2 supply voltage missing X72:25 E 1


no crane operation possible, entry in error list

215359 ZE 2: output group 3 supply voltage missing X72:13 E 1


no crane operation possible, entry in error list

220050 ZE 2: LSB participant address 0 reports an incorrect sensor type X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

220051 ZE 2: LSB participant address 0 was not configured for the block transfer X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

220053 ZE 2: LSB participant address 0 no longer reports or withdrawn during running period X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

220054 ZE 2: LSB participant address 0 Features other settings (parameters) as pre-entered set values X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

220064 ZE 2: LSB participant address 0 reports tolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

220065 ZE 2: LSB participant address 0 reports intolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

220066 ZE 2: LSB participant address 0 with software version, that is no longer compatible X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

220067 ZE 2: LSB participant address 0 supports no download function X635B:z14/z16 O-54.4/54.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

002389508 116
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

220150 ZE 2: LSB participant address 1 reports an incorrect sensor type X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

220151 ZE 2: LSB participant address 1 was not configured for the block transfer X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

220153 ZE 2: LSB participant address 1 no longer reports or withdrawn during running period X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

220154 ZE 2: LSB participant address 1 Features other settings (parameters) as pre-entered set values X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

220164 ZE 2: LSB participant address 1 reports tolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

220165 ZE 2: LSB participant address 1 reports intolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

220166 ZE 2: LSB participant address 1 with software version, that is no longer compatible X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

220167 ZE 2: LSB participant address 1 supports no download function X635B:z14/z16 O-54.4/54.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

222350 ZE 2: LSB participant address 23 reports an incorrect sensor type X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

222351 ZE 2: LSB participant address 23 was not configured for the block transfer X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

002389508 117
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

222353 ZE 2: LSB participant address 23 no longer reports or withdrawn during running period X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

222354 ZE 2: LSB participant address 23 Features other settings (parameters) as pre-entered set values X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

222363 ZE 2: LSB participant address 23 not available or open line X635B:z14/z16 O-54.4/54.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

222364 ZE 2: LSB participant address 23 reports tolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

222365 ZE 2: LSB participant address 23 reports intolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

222366 ZE 2: LSB participant address 23 with software version, that is no longer compatible X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

222367 ZE 2: LSB participant address 23 supports no download function X635B:z14/z16 O-54.4/54.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

222450 ZE 2: LSB participant address 24 reports an incorrect sensor type X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

222451 ZE 2: LSB participant address 24 was not configured for the block transfer X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

222453 ZE 2: LSB participant address 24 no longer reports or withdrawn during running period X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

002389508 118
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

222454 ZE 2: LSB participant address 24 Features other settings (parameters) as pre-entered set values X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

222463 ZE 2: LSB participant address 24 not available or open line X635B:z14/z16 O-54.4/54.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

222464 ZE 2: LSB participant address 24 reports tolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

222465 ZE 2: LSB participant address 24 reports intolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

222466 ZE 2: LSB participant address 24 with software version, that is no longer compatible X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

222467 ZE 2: LSB participant address 24 supports no download function X635B:z14/z16 O-54.4/54.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

222650 ZE 2: LSB participant address 26 reports an incorrect sensor type X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

222651 ZE 2: LSB participant address 26 was not configured for the block transfer X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

222653 ZE 2: LSB participant address 26 no longer reports or withdrawn during running period X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

222654 ZE 2: LSB participant address 26 Features other settings (parameters) as pre-entered set values X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

002389508 119
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

222663 ZE 2: LSB participant address 26 not available or open line X635B:z14/z16 O-54.4/54.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

222664 ZE 2: LSB participant address 26 reports tolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

222665 ZE 2: LSB participant address 26 reports intolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

222666 ZE 2: LSB participant address 26 with software version, that is no longer compatible X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

222667 ZE 2: LSB participant address 26 supports no download function X635B:z14/z16 O-54.4/54.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

222750 ZE 2: LSB participant address 27 reports an incorrect sensor type X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

222751 ZE 2: LSB participant address 27 was not configured for the block transfer X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

222753 ZE 2: LSB participant address 27 no longer reports or withdrawn during running period X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

222754 ZE 2: LSB participant address 27 Features other settings (parameters) as pre-entered set values X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

222763 ZE 2: LSB participant address 27 not available or open line X635B:z14/z16 O-54.4/54.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

002389508 120
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

222764 ZE 2: LSB participant address 27 reports tolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

222765 ZE 2: LSB participant address 27 reports intolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

222766 ZE 2: LSB participant address 27 with software version, that is no longer compatible X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

222767 ZE 2: LSB participant address 27 supports no download function X635B:z14/z16 O-54.4/54.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

222850 ZE 2: LSB participant address 28 reports an incorrect sensor type X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

222851 ZE 2: LSB participant address 28 was not configured for the block transfer X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

222853 ZE 2: LSB participant address 28 no longer reports or withdrawn during running period X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

222854 ZE 2: LSB participant address 28 Features other settings (parameters) as pre-entered set values X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

222863 ZE 2: LSB participant address 28 not available or open line X635B:z14/z16 O-54.4/54.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

222864 ZE 2: LSB participant address 28 reports tolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

002389508 121
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

222865 ZE 2: LSB participant address 28 reports intolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

222866 ZE 2: LSB participant address 28 with software version, that is no longer compatible X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

222867 ZE 2: LSB participant address 28 supports no download function X635B:z14/z16 O-54.4/54.4 E 1


entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

223206 ZE 2: Control data transfer LSB line connection to participant disrupted/not plugged in X635B:z14/z16 O-54.4/54.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check bus connections, if connections OK despite error then check sensor and replace if necessary

223252 ZE 2: Control data transfer LSB has recognised Bus collisions, communication interrupted X635B:z14/z16 O-54.4/54.4 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor

223255 ZE 2: Control data transfer LSB Bus connection faulty/defect, short circuit to supply voltage X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

223256 ZE 2: Control data transfer LSB Bus connection faulty/defect, no supply/short circuit to earth X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

223257 ZE 2: Control data transfer LSB has recognised network re-set (data transfer starts again) X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part

223258 ZE 2: Control data transfer LSB recognised participant with incorrect baud rate in bus X635B:z14/z16 O-54.4/54.4 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors

223259 ZE 2: Control data transfer LSB recognised communication breakdown in bus X635B:z14/z16 O-54.4/54.4 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network

002389508 122
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

223260 ZE 2: Control data transfer LSB driver error: no order to carry out X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software

223261 ZE 2: Control data transfer LSB driver error: undefined message appears X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination

223262 ZE 2: Control data transfer LSB driver error: initialising error X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination

226002 ZE 2: input 12 sensor deficiency data short circuit to supply voltage X635B:d26 E 1
report of error, otherwise no reaction
check supply, LICCON input, sensor lines to short or break, sensor

230500 ZE 2: remote control transmit, maximum transmission cycle radio contact exceeded E 1
radio control deactivated
check radio receiver/-transmitter (battery!)

230501 ZE 2: remote control receive, disrupted connection to receiver/interrupted E 1


radio control deactivated
check serial connection line to radio receiver

230502 ZE 2: remote control receive, transmission error (CRC) E 1


radio control temporarily deactivated
check serial connection line to radio receiver and radio receiver/ -transmitter

230503 ZE 2: remote control receive, transmission cycle mark exceeded E 1


radio control temporarily deactivated
check serial connection line to radio receiver and radio receiver/ -transmitter

230504 ZE 2: remote control receive, transmission cycle message exceeded E 1


radio control temporarily deactivated
check serial connection line to radio receiver and radio receiver/ -transmitter

232000 ZE 2: control winch 1 no slewing movement recognized on actuated winch E 1


output of error
check LICCON output, lines for short or break, incremental sensor on function, hoisting gear brake

002389508 123
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

232100 ZE 2: control winch 2 no slewing movement recognized on actuated winch E 1


output of error
check LICCON output, lines for short or break, incremental sensor on function, hoisting gear brake

233900 ZE 2: crane control signal engine speed defective/missing E 1


output of error, a medium speed will now be adjusted for the output limitation
check engine electronics, with permanent error contact after-sales service

233901 ZE 2: crane control signal actual engine torque-maximum defective/missing E 1


output of error, a medium torque will now be adjusted for the output limitation
check engine electronics, with permanent error contact after-sales service

233930 ZE 2: crane control signal pressure sensor "P" or "LS" defective/missing E 1


output of error, load-sensing-regulation will be shut down, therefore pure control to LS without pressure difference P
check supply, LICCON input, sensor lines to short or break, sensor

233933 ZE 2: crane control Signal press. tran. "P" lower lim value fallen short of (no press.! E 1
Diagnosis and output of error with "Control on without engine"
check supply, LICCON input, sensor lines to short or break, sensor

233934 ZE 2: crane control Signal pressure transducer "P" lower limit value exceeded (no press.!) E 1
Diagnosis and output of error with "Control on without engine"
check supply, LICCON input, sensor lines to short or break, sensor

233935 ZE 2: crane control Signal press. tran. "LS" lower lim value fallen short of (no press.!) E 1
Diagnosis and output of error with "Control on without engine"
check supply, LICCON input, sensor lines to short or break, sensor

233936 ZE 2: crane control Signal press. tran. "LS" lower limit value exceeded (no pressure!) E 1
Diagnosis and output of error with "Control on without engine"
check supply, LICCON input, sensor lines to short or break, sensor

233937 ZE 2: crane control Press. tran. "P" and "LS" outside permiss. signal diff (no press. E 1
Diagnosis and output of error with "Control on without engine"
Replace pressure transducer "P" and/or "LS"

233938 ZE 2: crane control Signal pressure transducer "P" greater "LS" (no pressure!) E 1
Diagnosis and output of error with "Control on without engine"
Swap pressure transducer "P" and "LS" with each other (mount P-sensor in LS position)

002389508 124
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

234200 ZE 2: instruments armrest right master switch 1Y both dir. contacts standing by simultaneously E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board

234201 ZE 2: instruments armrest right master switch 1X both dir. contacts standing by simultaneously E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board

234202 ZE 2: instruments armrest right master switch 1Y directional contact without zero contact E 1
output of error, shut-down through application
check supply, LICCON input, sensor lines for breaks , check defect sensor

234203 ZE 2: instruments armrest right master switch 1X directional contact without zero contact E 1
output of error, shut-down through application
check supply, LICCON input, sensor lines for breaks , check defect sensor

234204 ZE 2: instruments armrest right master switch 1Y analogue signal short to supply voltage E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board

234205 ZE 2: instruments armrest right master switch 1X analogue signal short to supply voltage E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board

234208 ZE 2: instruments armrest right master switch 1Y analogue sig. open circuit or short circ. to ground E 1
output of error, shut-down through application
check supply, LICCON input, sensor line for breaks , defect sensor through withdrawing of sensor

234209 ZE 2: instruments armrest right master switch 1X analogue sig. open circuit or short circ. to ground E 1
output of error, shut-down through application
check supply, LICCON input, sensor line for breaks , defect sensor through withdrawing of sensor

234312 ZE 2: instruments armrest left master switch 2Y both dir. contacts standing by simultaneously E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board

234314 ZE 2: instruments armrest left master switch 2Y directional contact without zero contact E 1
output of error, shut-down through application
check supply, LICCON input, sensor lines for breaks , check defect sensor

002389508 125
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

234316 ZE 2: instruments armrest left master switch 2Y analogue signal short to supply voltage E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board

234320 ZE 2: instruments armrest left master switch 2Y analogue sig. open circuit or short to ground E 1
output of error, shut-down through application
check supply, LICCON input, sensor line for breaks , defect sensor through withdrawing of sensor

234801 ZE 2: control diagnosis system tele angle sensor defective/missing E 1


Carrying out of test program delayed / interrupted
Check angle transmitter and connection, carry out test program again

234802 ZE 2: control diagnosis system winch incremental sensor defective/missing E 1


Carrying out of test program delayed / interrupted
Check incremental sensor winch, carry out test program again

234804 ZE 2: control diagnosis system end of stroke switch defective/missing E 1


Carrying out of test program delayed / interrupted
Check hoist limit switch and connection, lower hoist gear, carry out test program again

234805 ZE 2: control diagnosis system longitudinal sensor defective/missing E 1


Carrying out of test program delayed / interrupted
Check length indicator and connection, carry out test program again

234811 ZE 2: control diagnosis system Boom angle value(s) implausible E 1


Carrying out of test program delayed / interrupted
Check assembly / parameters / function of angle sensor

234820 ZE 2: control diagnosis system pressure value LS defective/missing E 1


Carrying out of test program delayed / interrupted
Check LS pressure transducer, carry out test program again

234821 ZE 2: control diagnosis system pressure value P defective/missing E 1


Carrying out of test program delayed / interrupted
Check P pressure transducer, carry out test program again

234822 ZE 2: control diagnosis system pressure value in luffing cylinder defective/missing E 1


Carrying out of test program delayed / interrupted
Check pressure transducer luffing cylinder, carry out test program again

002389508 126
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

234823 ZE 2: control diagnosis system pressure value in hoisting gear defective/missing E 1


Carrying out of test program delayed / interrupted
Adjust pressure, carry out test program again

234824 ZE 2: control diagnosis system Charge press. hoist gear or press. switch'Lower freely'faulty/not pre E 1
Carrying out of test program delayed / interrupted
Check charge pressure, carry out test program again

234826 ZE 2: control diagnosis system Qmin value faulty / not present E 1


Carrying out of test program delayed / interrupted
Check Qmin pump, carry out test program again

234830 ZE 2: control diagnosis system Pressure cut-off pump outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure reduction and pressure limitation LS, carry out test program again

234831 ZE 2: control diagnosis system Pressure cut-off hoist gear lift outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure hoist gear, carry out test program again

234832 ZE 2: control diagnosis system Pressure cut-off hoist gear lower outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure hoist gear, carry out test program again

234845 ZE 2: control diagnosis system Winch turns with no brake selected E 1


Carrying out of test program delayed / interrupted
Check hoist gear brake, carry out test program again

234846 ZE 2: control diagnosis system Initial current winch lift above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234847 ZE 2: control diagnosis system Initial current winch lift below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234848 ZE 2: control diagnosis system Initial current winch lower above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

002389508 127
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

234849 ZE 2: control diagnosis system Initial current winch lower below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234850 ZE 2: control diagnosis system winch speed hoisting too high E 1


Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234851 ZE 2: control diagnosis system winch speed hoisting too low E 1


Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234852 ZE 2: control diagnosis system winch speed lowering too low E 1


Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234853 ZE 2: control diagnosis system winch speed lowering too high E 1


Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234854 ZE 2: control diagnosis system Hysteresis winch lift too great E 1


Carrying out of test program delayed / interrupted
Check proportional-flow valve

234855 ZE 2: control diagnosis system Hysteresis winch lower too great E 1


Carrying out of test program delayed / interrupted
Check proportional-flow valve

234867 ZE 2: control diagnosis system Initial current luffing up above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234868 ZE 2: control diagnosis system Initial current luffing up below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234869 ZE 2: control diagnosis system Initial current luffing down above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

002389508 128
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

234870 ZE 2: control diagnosis system Initial current luffing down below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234871 ZE 2: control diagnosis system luffing speed luffing up too low E 1


Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234872 ZE 2: control diagnosis system luffing speed luffing up too high E 1


Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234873 ZE 2: control diagnosis system luffing speed luffing down too low E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234874 ZE 2: control diagnosis system luffing speed luffing down too high E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234875 ZE 2: control diagnosis system Hysteresis luffing up too great E 1


Carrying out of test program delayed / interrupted
Check proportional-flow valve

234876 ZE 2: control diagnosis system Hysteresis luffing down too great E 1


Carrying out of test program delayed / interrupted
Check proportional-flow valve

234888 ZE 2: control diagnosis system Initial current pump 1 above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234889 ZE 2: control diagnosis system Initial current pump 1 below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234892 ZE 2: control diagnosis system Pump 1 final current or flow-rate below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

002389508 129
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

234893 ZE 2: control diagnosis system Pump 1 final current or flow-rate above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

234896 ZE 2: control diagnosis system Hysteresis pump 1 outside of permissible area E 1


Carrying out of test program delayed / interrupted
Check pump

234897 ZE 2: control diagnosis system Hysteresis pump 2 outside of permissible area E 1


Carrying out of test program delayed / interrupted
Check pump

234898 ZE 2: control diagnosis system Readjustment of hoist gear lift outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check controller / gate valve / pressure balance / pump(s)

234899 ZE 2: control diagnosis system Readjustment hoist gear lower outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check controller / gate valve / pressure balance / pump(s)

235004 ZE 2: operation winch 1 unreeled winch shut-down B


operational shut down
reel in winch until the "winch reeled out" switch is no longer actuated - shut-down cannot be shunted

235020 ZE 2: operation winch 1 LMB shut-down B


operational shut down
the "STOP" symbol appears in operation screen, the cause can be displayed through an LMB error output

235029 ZE 2: operation winch 1 winch blocked (C-key monitor) B


operational shut down
disengage winch 1 in the control screen

235030 ZE 2: operation winch 1 master switch 1 defective/missing B


operational shut down
briefly release master switch, or error elimination see corresponding system error

235039 ZE 2: operation winch 1 seat contact shut-down B


operational shut down
sit down (seat limit switch) or dead man (in master switch) or check LICCON input, sensor lines, sensor

002389508 130
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

235049 ZE 2: operation winch 1 Shut-down hoist limit switch 4 B


operational shut down
reel out winch until the end of stroke switch is no longer active - shut-down can be shunted (danger)

235050 ZE 2: operation winch 1 end of stroke switch shut-down 1 B


operational shut down
reel out winch until the end of stroke switch is no longer active - shut-down can be shunted (danger)

235051 ZE 2: operation winch 1 end of stroke switch shut-down 2 B


operational shut down
reel out winch until the end of stroke switch is no longer active - shut-down can be shunted (danger)

235052 ZE 2: operation winch 1 end of stroke switch shut-down 3 B


operational shut down
reel out winch until the end of stroke switch is no longer active - shut-down can be shunted (danger)

235081 ZE 2: operation winch 1 end of stroke switch 1 shut-down defective B


operational shut down
Check hoist limit switch - shut-down may be shunted (danger)

235082 ZE 2: operation winch 1 end of stroke switch 2 shut-down defective B


operational shut down
Check hoist limit switch - shut-down may be shunted (danger)

235083 ZE 2: operation winch 1 end of stroke switch 3 shut-down defective B


operational shut down
Check hoist limit switch - shut-down may be shunted (danger)

235089 ZE 2: operation winch 1 Shut-down hoist limit switch 4 faulty B


operational shut down
Check hoist limit switch - shut-down may be shunted (danger)

235090 ZE 2: operation winch 1 hoisting gear pressure switch shut-down B


operational shut down
check section in the LS-strut, LICCON output, line to short, pressure switch function

235104 ZE 2: operation winch 2 unreeled winch shut-down B


operational shut down
reel in winch until the "winch reeled out" switch is no longer actuated - shut-down cannot be shunted

002389508 131
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

235120 ZE 2: operation winch 2 LMB shut-down B


operational shut down
eliminate cause of the "LMB Stop" see error report LMB - shut-down can be shunted (danger)

235129 ZE 2: operation winch 2 winch blocked (C-key monitor) B


operational shut down
release winch 2 in the control screen

235131 ZE 2: operation winch 2 master switch 2 defective/missing B


operational shut down
briefly release master switch, or error elimination see corresponding system error

235139 ZE 2: operation winch 2 seat contact shut-down B


operational shut down
sit down (seat limit switch) or dead man (in master switch) or check LICCON input, sensor lines, sensor

235149 ZE 2: operation winch 2 Shut-down hoist limit switch 4 B


operational shut down
reel out winch until the end of stroke switch is no longer active - shut-down can be shunted (danger)

235150 ZE 2: operation winch 2 end of stroke switch shut-down 1 B


operational shut down
reel out winch until the end of stroke switch is no longer active - shut-down can be shunted (danger)

235151 ZE 2: operation winch 2 end of stroke switch shut-down 2 B


operational shut down
reel out winch until the end of stroke switch is no longer active - shut-down can be shunted (danger)

235152 ZE 2: operation winch 2 end of stroke switch shut-down 3 B


operational shut down
reel out winch until the end of stroke switch is no longer active - shut-down can be shunted (danger)

235181 ZE 2: operation winch 2 end of stroke switch 1 shut-down defective B


operational shut down
Check hoist limit switch - shut-down may be shunted (danger)

235182 ZE 2: operation winch 2 end of stroke switch 2 shut-down defective B


operational shut down
Check hoist limit switch - shut-down may be shunted (danger)

002389508 132
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

235183 ZE 2: operation winch 2 end of stroke switch 3 shut-down defective B


operational shut down
Check hoist limit switch - shut-down may be shunted (danger)

235189 ZE 2: operation winch 2 Shut-down hoist limit switch 4 faulty B


operational shut down
Check hoist limit switch - shut-down may be shunted (danger)

235190 ZE 2: operation winch 2 hoisting gear pressure switch shut-down B


operational shut down
check section in the LS-strut, LICCON output, line to short, pressure switch function

235706 ZE 2: operation luffing upper angle limit OGW shut-down B


operational shut down
luff main boom down until radius is within load chart again - shut-down can be shunted (danger)

235707 ZE 2: operation luffing lower angle limit UGW shut-down B


operational shut down
luff main boom up until radius is within load chart again- shut-down can be shunted (danger)

235708 ZE 2: operation luffing luffing up of main boom shut-down working area limitation ABB B
operational shut down
luff main boom down until crane is in working area again - shunting through shut-down of working area limitation

235709 ZE 2: operation luffing luffing down of main boom shut-down working area limitation ABB B
operational shut down
luff main boom up until crane in working area again - shunting through shut-down of working area limitation

235720 ZE 2: operation luffing LMB shut-down B


operational shut down
eliminate cause of the "LMB Stop" see error report LMB - shut-down can be shunted (danger)

235730 ZE 2: operation luffing master switch 1 defective/missing B


operational shut down
briefly release master switch, or error elimination see corresponding system error

235739 ZE 2: operation luffing seat contact shut-down B


operational shut down
sit down (seat limit switch) or dead man (in master switch) or check LICCON input, sensor lines, sensor

002389508 133
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

235747 ZE 2: operation luffing Warning luffing up, dropping of load with reduction of reach B

235748 ZE 2: operation luffing Shut-down luffing up, dropping of load with reduction of reach B

235749 ZE 2: operation luffing Shut-down hoist limit switch 4 B

235750 ZE 2: operation luffing end of stroke switch shut-down 1 B


operational shut down
luff main boom up until end of stroke switch is no longer activated - shut-down can be shunted(danger)

235751 ZE 2: operation luffing end of stroke switch shut-down 2 B


operational shut down
luff main boom up until end of stroke switch is no longer activated - shut-down can be shunted(danger)

235752 ZE 2: operation luffing end of stroke switch shut-down 3 B


operational shut down
luff main boom up until end of stroke switch is no longer activated - shut-down can be shunted(danger)

235760 ZE 2: operation luffing Shut-down limit switch main boom steep B

235760 ZE 2: operation luffing Shut-down limit switch main boom steep B

235781 ZE 2: operation luffing end of stroke switch 1 shut-down defective B

235782 ZE 2: operation luffing end of stroke switch 2 shut-down defective B

002389508 134
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

235783 ZE 2: operation luffing end of stroke switch 3 shut-down defective B

235789 ZE 2: operation luffing Shut-down hoist limit switch 4 faulty B

236100 ZE 2: Operation ballasting / counterweight carriage Counterweight UP selected, final position not started B 1
report of error, otherwise no reaction
Approach end position, if ok check: -supply, -input LICCON, -sensor line for short-circuit or interruption, -

236101 ZE 2: Operation ballasting / counterweight carriage Counterweight DOWN selected, final position not started B 1
report of error, otherwise no reaction
Approach end position, if ok check: -supply, -input LICCON, -sensor line for short-circuit or interruption, -

237049 ZE 2: operation instruments crane operators cab seat contact not activated, crane movements blocked B 1
output of error, shut-down through application
sit down (seat limit switch) or dead man (in master switch) or check LICCON input, sensor lines, sensor

237200 ZE 2: operation instruments armrest right master switch 1Y not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor

237201 ZE 2: operation instruments armrest right master switch 1X not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor

237312 ZE 2: operation instruments armrest left master switch 2Y not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor

239800 ZE 2: operation diagnosis system interruption, master switch defective or incorrectly deflected B 1
Carrying out of test program delayed / interrupted
Note direction of movements, carry out test program again

239801 ZE 2: operation diagnosis system interruption, master switch defective/missing B 1


Carrying out of test program delayed / interrupted
Check master switch, carry out test program again

002389508 135
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

239802 ZE 2: operation diagnosis system interruption, incorrect or no operation mode B 1


Carrying out of test program delayed / interrupted
Set correct operation type, if necessary dismantle accessory, carry out test program again

239804 ZE 2: operation diagnosis system Termination, change-over luff/telescoping incorrect switch position B
Carrying out of test program delayed / interrupted
Check valve / pump / pressure

239810 ZE 2: operation diagnosis system Termination, winch blocked B 1


Carrying out of test program delayed / interrupted
Disconnect winch, carry out test program again

239811 ZE 2: operation diagnosis system Termination, high-speed not keyed-in B 1


Carrying out of test program delayed / interrupted
Key in high gear, carry out test program again

239812 ZE 2: operation diagnosis system Termination, windable rope length too short B 1
Carrying out of test program delayed / interrupted
Check reeving wind off more rope, carry out test program again

239813 ZE 2: operation diagnosis system Termination, maximum speed < 100% (C-key) B 1
Carrying out of test program delayed / interrupted
Adjust speed C key to 100%, carry out test program again

239814 ZE 2: operation diagnosis system Alignment aid not correctly shut down B 1
Invalid operation condition, no proper crane operation possible
Apply F key, end active test program

239820 ZE 2: operation diagnosis system interruption, boom angle beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct luffing position, carry out test program again

239821 ZE 2: operation diagnosis system interruption, tele length beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct telescopic boom length length, carry out test program again

239822 ZE 2: operation diagnosis system interruption, hook load beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Note max. hook load, carry out test program again

002389508 136
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

239823 ZE 2: operation diagnosis system interruption, incorrect reeving B 1


Carrying out of test program delayed / interrupted
Note lowest amount of reevings, carry out test program again

239824 ZE 2: operation diagnosis system interruption, end of stroke switch activated/defective/missing B 1


Carrying out of test program delayed / interrupted
Check hoist limit switch, carry out test program again

239830 ZE 2: operation diagnosis system Termination, op. temperature hydraulic oil below permissible area B 1
Carrying out of test program delayed / interrupted
Operate engine and hydraulics to operating temperature, erase error, actuate Reset and start again

239831 ZE 2: operation diagnosis system Termination, op. temperature hydraulic oil above permissible area B 1
Test program is interrupted, set value not needed
Allow hydr to cool, if nec. operate tele. boom length (cool via oil change),erase err, actuate Reset and restart

261001 E/A-Modul 2: system error OS-C167 initialising error processor-register erroneous E 2


error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

261002 E/A-Modul 2: system error OS-C167 initialising error test total in EPROM/FLASH erroneous E 2
error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

261006 E/A-Modul 2: system error OS-C167 initialising error RAM erroneous E 2


error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

261013 E/A-Modul 2: system error OS-C167 test total in EPROM/FLASH erroneous E 2


error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

261016 E/A-Modul 2: system error OS-C167 system-, driver-watchdog expired E 2


error indication on display
note error report, ignition On/Off, with regular occurrence --> notify after-sales service

261068 E/A-Modul 2: system error OS-C167 impermissible interrupt E 2


error indication on display
note error report, ignition On/Off, with regular occurrence --> notify after-sales service

002389508 137
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

261080 E/A-Modul 2: system error OS-C167 fatal internal software error E 2


error indication on display
note error report, ignition On/Off, with regular occurrence --> notify after-sales service

261082 E/A-Modul 2: system error OS-C167 hardware-watchdog erroneous E 2


error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

272052 E/A-Modul 2: input/output DEA0 output open, to low load, short circuit to supply voltage X623:17 U-69.6 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

272053 E/A-Modul 2: input/output DEA0 transistor current supply insufficient or missing X623:17 U-69.6 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

272054 E/A-Modul 2: input/output DEA0 short circuit to supply voltage X623:17 U-69.6 E 1
error report on display
check output for short, if necessary replace E/A-Modul

272055 E/A-Modul 2: input/output DEA0 excessive temperature, short circuit to ground or overload X623:17 U-69.6 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

272152 E/A-Modul 2: input/output DEA1 output open, to low load, short circuit to supply voltage X623:15 U-60.2 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

272153 E/A-Modul 2: input/output DEA1 transistor current supply insufficient or missing X623:15 U-60.2 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

272154 E/A-Modul 2: input/output DEA1 short circuit to supply voltage X623:15 U-60.2 E 1
error report on display
check output for short, if necessary replace E/A-Modul

272155 E/A-Modul 2: input/output DEA1 excessive temperature, short circuit to ground or overload X623:15 U-60.2 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

002389508 138
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

272252 E/A-Modul 2: input/output DEA2 output open, to low load, short circuit to supply voltage X623:13 U-69.5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

272253 E/A-Modul 2: input/output DEA2 transistor current supply insufficient or missing X623:13 U-69.5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

272254 E/A-Modul 2: input/output DEA2 short circuit to supply voltage X623:13 U-69.5 E 1
error report on display
check output for short, if necessary replace E/A-Modul

272255 E/A-Modul 2: input/output DEA2 excessive temperature, short circuit to ground or overload X623:13 U-69.5 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

272352 E/A-Modul 2: input/output DEA3 output open, to low load, short circuit to supply voltage X623:11 U-71.2 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

272353 E/A-Modul 2: input/output DEA3 transistor current supply insufficient or missing X623:11 U-71.2 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

272354 E/A-Modul 2: input/output DEA3 short circuit to supply voltage X623:11 U-71.2 E 1
error report on display
check output for short, if necessary replace E/A-Modul

272355 E/A-Modul 2: input/output DEA3 excessive temperature, short circuit to ground or overload X623:11 U-71.2 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

272452 E/A-Modul 2: input/output DEA4 output open, to low load, short circuit to supply voltage X623:9 U-71.3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

272453 E/A-Modul 2: input/output DEA4 transistor current supply insufficient or missing X623:9 U-71.3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

002389508 139
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

272454 E/A-Modul 2: input/output DEA4 short circuit to supply voltage X623:9 U-71.3 E 1
error report on display
check output for short, if necessary replace E/A-Modul

272455 E/A-Modul 2: input/output DEA4 excessive temperature, short circuit to ground or overload X623:9 U-71.3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

272552 E/A-Modul 2: input/output DEA5 output open, to low load, short circuit to supply voltage X623:7 U-70.3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

272553 E/A-Modul 2: input/output DEA5 transistor current supply insufficient or missing X623:7 U-70.3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

272554 E/A-Modul 2: input/output DEA5 short circuit to supply voltage X623:7 U-70.3 E 1
error report on display
check output for short, if necessary replace E/A-Modul

272555 E/A-Modul 2: input/output DEA5 excessive temperature, short circuit to ground or overload X623:7 U-70.3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

272652 E/A-Modul 2: input/output DEA6 output open, to low load, short circuit to supply voltage X623:5 U-70.1 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

272653 E/A-Modul 2: input/output DEA6 transistor current supply insufficient or missing X623:5 U-70.1 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

272654 E/A-Modul 2: input/output DEA6 short circuit to supply voltage X623:5 U-70.1 E 1
error report on display
check output for short, if necessary replace E/A-Modul

272655 E/A-Modul 2: input/output DEA6 excessive temperature, short circuit to ground or overload X623:5 U-70.1 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

002389508 140
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

272752 E/A-Modul 2: input/output DEA7 output open, to low load, short circuit to supply voltage X623:3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

272753 E/A-Modul 2: input/output DEA7 transistor current supply insufficient or missing X623:3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

272754 E/A-Modul 2: input/output DEA7 short circuit to supply voltage X623:3 E 1


error report on display
check output for short, if necessary replace E/A-Modul

272755 E/A-Modul 2: input/output DEA7 excessive temperature, short circuit to ground or overload X623:3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

273481 E/A-Modul 2: voltage input E4 short circuit to supply voltage, open line X622:9 U-66.3 E 1
symbol for compressed air supply 1 is flashing on the display unit
check input signal on the E/A-Modul or sensor

273581 E/A-Modul 2: voltage input E5 short circuit to supply voltage, open line X622:7 U-66.5 E 1
symbol for compressed air supply 2 is flashing on the display unit
check input signal on the E/A-Modul or sensor

273681 E/A-Modul 2: voltage input E6 short circuit to supply voltage, open line X622:5 U-66.7 E 1
symbol for compressed air supply 3 is flashing on the display unit
check input signal on the E/A-Modul or sensor

273782 E/A-Modul 2: voltage input E7 short circuit to ground, open line, constant current 10 mA incorrect X622:4 U-53.8 E 1
no reaction
check input signal on the E/A-Modul or sensor

273783 E/A-Modul 2: voltage input E7 short circuit to supply voltage, open line, lack of voltage X622:4 U-53.8 E 1
no reaction
check input signal on the E/A-Modul or sensor

279052 E/A-Modul 2: output A0 output open, to low load, short circuit to supply voltage X623:18 U-60.1 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

002389508 141
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

279053 E/A-Modul 2: output A0 transistor current supply insufficient or missing X623:18 U-60.1 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

279054 E/A-Modul 2: output A0 short circuit to supply voltage X623:18 U-60.1 E 1


error report on display
check output for short, if necessary replace E/A-Modul

279055 E/A-Modul 2: output A0 excessive temperature, short circuit to ground or overload X623:18 U-60.1 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

279152 E/A-Modul 2: output A1 output open, to low load, short circuit to supply voltage X623:16 U-60.3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

279153 E/A-Modul 2: output A1 transistor current supply insufficient or missing X623:16 U-60.3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

279154 E/A-Modul 2: output A1 short circuit to supply voltage X623:16 U-60.3 E 1


error report on display
check output for short, if necessary replace E/A-Modul

279155 E/A-Modul 2: output A1 excessive temperature, short circuit to ground or overload X623:16 U-60.3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

279250 E/A-Modul 2: bridge output A2 short circuit to ground, junction not supplied X623:14 U-61.3 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul

279251 E/A-Modul 2: bridge output A2 short circuit to supply voltage, excessive temperature X623:14 U-61.3 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul

279252 E/A-Modul 2: bridge output A2 output open, to low load, short circuit to supply voltage X623:14 U-61.3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

002389508 142
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

279253 E/A-Modul 2: bridge output A2 transistor current supply insufficient or missing X623:14 U-61.3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

279254 E/A-Modul 2: bridge output A2 short circuit to supply voltage X623:14 U-61.3 E 1
error report on display
check output for short, if necessary replace E/A-Modul

279255 E/A-Modul 2: bridge output A2 excessive temperature, short circuit to ground or overload X623:14 U-61.3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

279350 E/A-Modul 2: bridge output A3 short circuit to ground, junction not supplied X623:12 U-61.3 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul

279351 E/A-Modul 2: bridge output A3 short circuit to supply voltage, excessive temperature X623:12 U-61.3 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul

279352 E/A-Modul 2: bridge output A3 output open, to low load, short circuit to supply voltage X623:12 U-61.3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

279353 E/A-Modul 2: bridge output A3 transistor current supply insufficient or missing X623:12 U-61.3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

279354 E/A-Modul 2: bridge output A3 short circuit to supply voltage X623:12 U-61.3 E 1
error report on display
check output for short, if necessary replace E/A-Modul

279355 E/A-Modul 2: bridge output A3 excessive temperature, short circuit to ground or overload X623:12 U-61.3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

283301 E/A-Modul 2: SPI-display unit Faulty data transfer E/A-module<>unit (time exceeded) X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

002389508 143
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

283302 E/A-Modul 2: SPI-display unit Serious system error to SPI-connection (interface) X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

283303 E/A-Modul 2: SPI-display unit break in line or short circuit to supply voltage X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary

283304 E/A-Modul 2: SPI-display unit break in line or short circuit to ground X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary

283306 E/A-Modul 2: SPI-display unit Data transfer faulty (faulty check byte) X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
suppress EMV- interference

283307 E/A-Modul 2: SPI-display unit Unit faulty/missing, incorrect unit inserted (ID) X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
check periphery and replace if necessary, check Software version, check EMV- interference

283308 E/A-Modul 2: SPI-display unit Data transfer faulty (incorrect number of data bytes received) X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

283900 E/A-Modul 2: Control operating unit (SPI) Faulty initialisation data connection E/A-module<>unit X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

283902 E/A-Modul 2: Control operating unit (SPI) Serious system error to SPI-connection (interface) X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

283905 E/A-Modul 2: Control operating unit (SPI) Initialisation error, resetting inputs/outputs faulty X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
check wiring, check periphery and replace if necessary, check E/A-Modul and replace if necessary

283907 E/A-Modul 2: Control operating unit (SPI) Unit faulty/missing, incorrect unit inserted (ID) X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
connect functional periphery unit, system then eliminates error independently

002389508 144
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

283908 E/A-Modul 2: Control operating unit (SPI) Data transfer faulty (incorrect number of data bytes received) X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

284050 E/A-Modul 2: LSB-B participant address 0 reports an incorrect sensor type X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

284051 E/A-Modul 2: LSB-B participant address 0 was not configured for the block transfer X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

284053 E/A-Modul 2: LSB-B participant address 0 no longer reports or withdrawn during running period X623:4/6 U-46.5/46.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

284054 E/A-Modul 2: LSB-B participant address 0 Features other settings (parameters) as pre-entered set values X623:4/6 U-46.5/46.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

284064 E/A-Modul 2: LSB-B participant address 0 reports tolerable error in self-test X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

284065 E/A-Modul 2: LSB-B participant address 0 reports intolerable error in self-test X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

284066 E/A-Modul 2: LSB-B participant address 0 with software version, that is no longer compatible X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

284067 E/A-Modul 2: LSB-B participant address 0 supports no download function X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

284150 E/A-Modul 2: LSB-B participant address 1 reports an incorrect sensor type X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

002389508 145
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

284151 E/A-Modul 2: LSB-B participant address 1 was not configured for the block transfer X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

284153 E/A-Modul 2: LSB-B participant address 1 no longer reports or withdrawn during running period X623:4/6 U-46.5/46.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

284154 E/A-Modul 2: LSB-B participant address 1 Features other settings (parameters) as pre-entered set values X623:4/6 U-46.5/46.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

284164 E/A-Modul 2: LSB-B participant address 1 reports tolerable error in self-test X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

284165 E/A-Modul 2: LSB-B participant address 1 reports intolerable error in self-test X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

284166 E/A-Modul 2: LSB-B participant address 1 with software version, that is no longer compatible X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

284167 E/A-Modul 2: LSB-B participant address 1 supports no download function X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

284250 E/A-Modul 2: LSB-B participant address 2 reports an incorrect sensor type X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

284251 E/A-Modul 2: LSB-B participant address 2 was not configured for the block transfer X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

284253 E/A-Modul 2: LSB-B participant address 2 no longer reports or withdrawn during running period X623:4/6 U-46.5/46.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

002389508 146
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

284254 E/A-Modul 2: LSB-B participant address 2 Features other settings (parameters) as pre-entered set values X623:4/6 U-46.5/46.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

284264 E/A-Modul 2: LSB-B participant address 2 reports tolerable error in self-test X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

284265 E/A-Modul 2: LSB-B participant address 2 reports intolerable error in self-test X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

284266 E/A-Modul 2: LSB-B participant address 2 with software version, that is no longer compatible X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

284267 E/A-Modul 2: LSB-B participant address 2 supports no download function X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

284350 E/A-Modul 2: LSB-B participant address 3 reports an incorrect sensor type X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

284351 E/A-Modul 2: LSB-B participant address 3 was not configured for the block transfer X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

284353 E/A-Modul 2: LSB-B participant address 3 no longer reports or withdrawn during running period X623:4/6 U-46.5/46.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

284354 E/A-Modul 2: LSB-B participant address 3 Features other settings (parameters) as pre-entered set values X623:4/6 U-46.5/46.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

284364 E/A-Modul 2: LSB-B participant address 3 reports tolerable error in self-test X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

002389508 147
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

284365 E/A-Modul 2: LSB-B participant address 3 reports intolerable error in self-test X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

284366 E/A-Modul 2: LSB-B participant address 3 with software version, that is no longer compatible X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

284367 E/A-Modul 2: LSB-B participant address 3 supports no download function X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

284450 E/A-Modul 2: LSB-B participant address 4 reports an incorrect sensor type X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

284451 E/A-Modul 2: LSB-B participant address 4 was not configured for the block transfer X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

284453 E/A-Modul 2: LSB-B participant address 4 no longer reports or withdrawn during running period X623:4/6 U-46.5/46.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

284454 E/A-Modul 2: LSB-B participant address 4 Features other settings (parameters) as pre-entered set values X623:4/6 U-46.5/46.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

284464 E/A-Modul 2: LSB-B participant address 4 reports tolerable error in self-test X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

284465 E/A-Modul 2: LSB-B participant address 4 reports intolerable error in self-test X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

284466 E/A-Modul 2: LSB-B participant address 4 with software version, that is no longer compatible X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

002389508 148
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

284467 E/A-Modul 2: LSB-B participant address 4 supports no download function X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

284550 E/A-Modul 2: LSB-B participant address 5 reports an incorrect sensor type X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

284551 E/A-Modul 2: LSB-B participant address 5 was not configured for the block transfer X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

284553 E/A-Modul 2: LSB-B participant address 5 no longer reports or withdrawn during running period X623:4/6 U-46.5/46.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

284554 E/A-Modul 2: LSB-B participant address 5 Features other settings (parameters) as pre-entered set values X623:4/6 U-46.5/46.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

284564 E/A-Modul 2: LSB-B participant address 5 reports tolerable error in self-test X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

284565 E/A-Modul 2: LSB-B participant address 5 reports intolerable error in self-test X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

284566 E/A-Modul 2: LSB-B participant address 5 with software version, that is no longer compatible X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

284567 E/A-Modul 2: LSB-B participant address 5 supports no download function X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

284650 E/A-Modul 2: LSB-B participant address 6 reports an incorrect sensor type X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

002389508 149
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

284651 E/A-Modul 2: LSB-B participant address 6 was not configured for the block transfer X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

284653 E/A-Modul 2: LSB-B participant address 6 no longer reports or withdrawn during running period X623:4/6 U-46.5/46.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

284654 E/A-Modul 2: LSB-B participant address 6 Features other settings (parameters) as pre-entered set values X623:4/6 U-46.5/46.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

284664 E/A-Modul 2: LSB-B participant address 6 reports tolerable error in self-test X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

284665 E/A-Modul 2: LSB-B participant address 6 reports intolerable error in self-test X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

284666 E/A-Modul 2: LSB-B participant address 6 with software version, that is no longer compatible X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

284667 E/A-Modul 2: LSB-B participant address 6 supports no download function X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

285050 E/A-Modul 2: LSB-B participant address 10 reports an incorrect sensor type X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

285051 E/A-Modul 2: LSB-B participant address 10 was not configured for the block transfer X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

285053 E/A-Modul 2: LSB-B participant address 10 no longer reports or withdrawn during running period X623:4/6 U-46.5/46.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

002389508 150
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

285054 E/A-Modul 2: LSB-B participant address 10 Features other settings (parameters) as pre-entered set values X623:4/6 U-46.5/46.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

285064 E/A-Modul 2: LSB-B participant address 10 reports tolerable error in self-test X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

285065 E/A-Modul 2: LSB-B participant address 10 reports intolerable error in self-test X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

285066 E/A-Modul 2: LSB-B participant address 10 with software version, that is no longer compatible X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

285067 E/A-Modul 2: LSB-B participant address 10 supports no download function X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

287252 E/A-Modul 2: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X623:4/6 U-46.5/46.4 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor

287255 E/A-Modul 2: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X623:4/6 U-46.5/46.4 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

287256 E/A-Modul 2: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X623:4/6 U-46.5/46.4 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

287257 E/A-Modul 2: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X623:4/6 U-46.5/46.4 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part

287258 E/A-Modul 2: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X623:4/6 U-46.5/46.4 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors

002389508 151
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

287259 E/A-Modul 2: Control data transfer LSB-B recognised communication breakdown in bus X623:4/6 U-46.5/46.4 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network

287260 E/A-Modul 2: Control data transfer LSB-B driver error: no order to carry out X623:4/6 U-46.5/46.4 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software

287261 E/A-Modul 2: Control data transfer LSB-B driver error: undefined message appears X623:4/6 U-46.5/46.4 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination

287262 E/A-Modul 2: Control data transfer LSB-B driver error: initialising error X623:4/6 U-46.5/46.4 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination

287530 E/A-Modul 2: CAN-participant engine Data transfer subscriber transfer cycle exceeded X625:5/6 U-51.4/51.4 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

287531 E/A-Modul 2: CAN-participant engine Data transfer faulty/missing, max. cycle time exceeded X625:5/6 U-51.4/51.4 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

287630 E/A-Modul 2: CAN-participant gear Data transfer subscriber transfer cycle exceeded X625:5/6 U-51.4/51.4 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

287631 E/A-Modul 2: CAN-participant gear Data transfer faulty/missing, max. cycle time exceeded X625:5/6 U-51.4/51.4 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

287730 E/A-Modul 2: CAN-participant ABV (ABS/ASR) Data transfer subscriber transfer cycle exceeded X625:5/6 U-51.4/51.4 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

287731 E/A-Modul 2: CAN-participant ABV (ABS/ASR) Data transfer faulty/missing, max. cycle time exceeded X625:5/6 U-51.4/51.4 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

002389508 152
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

288530 E/A-Modul 2: CAN-participant E/A-Modul 1 Data transfer subscriber transfer cycle exceeded X625:5/6 U-51.4/51.4 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

288531 E/A-Modul 2: CAN-participant E/A-Modul 1 Data transfer faulty/missing, max. cycle time exceeded X625:5/6 U-51.4/51.4 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

288630 E/A-Modul 2: CAN-participant E/A-Modul 2 Data transfer subscriber transfer cycle exceeded X625:5/6 U-51.4/51.4 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

288631 E/A-Modul 2: CAN-participant E/A-Modul 2 Data transfer faulty/missing, max. cycle time exceeded X625:5/6 U-51.4/51.4 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

288930 E/A-Modul 2: CAN-participant E/A-Modul 5 Data transfer subscriber transfer cycle exceeded X625:5/6 U-51.4/51.4 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

288931 E/A-Modul 2: CAN-participant E/A-Modul 5 Data transfer faulty/missing, max. cycle time exceeded X625:5/6 U-51.4/51.4 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

289900 E/A-Modul 2: Control data transfer CAN internal error: register error CAN-controller X625:5/6 U-51.4/51.4 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul

289901 E/A-Modul 2: Control data transfer CAN internal error: RAM-error CAN-controller X625:5/6 U-51.4/51.4 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul

289902 E/A-Modul 2: Control data transfer CAN configuration error CAN-software X625:5/6 U-51.4/51.4 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul, check Software (test system ZE)

289903 E/A-Modul 2: Control data transfer CAN Transfer interrupted after continuous error X625:5/6 U-51.4/51.4 E 1
CAN-Transmission will be aborted
check bus lines/neutral point, replace neutral point or E/A-Modul

002389508 153
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

289910 E/A-Modul 2: Control data transfer CAN short-term error in bus connection X625:5/6 U-51.4/51.4 E 0
re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated

289911 E/A-Modul 2: Control data transfer CAN permanent error bus connection X625:5/6 U-51.4/51.4 E 1
cyclic re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated

289920 E/A-Modul 2: Control data transfer CAN active participant not responding X625:5/6 U-51.4/51.4 E 0
parameterised substitute values for receiver signals will be used
check error report for missing participant(s), test system ZE

289921 E/A-Modul 2: Control data transfer CAN No active subscriber responding X625:5/6 U-51.4/51.4 E 1
parameterised substitute values for receiver signals will be used
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul

289950 E/A-Modul 2: Control data transfer CAN erroneous command test system X625:5/6 U-51.4/51.4 E 1
no reaction to unknown test system control command in CAN-System Software
check Software (test system)

292000 E/A-Modul 2: control engine long-term disruption E/A-Modul <-> accelerator crane op. cab E 1
until the error is reset the engine speed setting for crane operation remains in idle
check LSB-connection ZE<>E/A-Modul, crane operators cab accelerator or connection to ZE (test system)

292001 E/A-Modul 2: control engine long-term disruption E/A-Modul <-> engine control E 1
engine control and E/A-Modul at emergency speed
engine control and E/A-Modul, check CAN-bus-connections

292225 E/A-Modul 2: control ABV incorrect system identification from control device E 2
function of brake system possibly restricted, function of ABV possibly restricted or not possible
replace electronics immediately or remove

293040 E/A-Modul 2: control hydraulic/second. power outputs feedback crane hydr. pump active in crane op. missing E 1
in case the pump is mechanically engaged, crane operation is possible
check pump pneumatic engagement mechanism, crane pump position; engage pump manually (engine OFF)

293041 E/A-Modul 2: control hydraulic/second. power outputs feedback crane hydr. pump inactive in travel op. missing E 1
in case the pump is mechanically engaged, pump can be damaged in travel operation due to excessive speed
Check pneumatic engagement mechanism of pump, position of sensor crane pump; disengage manual pump (engine OFF)

002389508 154
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

293042 E/A-Modul 2: control hydraulic/second. power outputs no signal from feedback sensor pump crane hydraulics E 1
error report, no acknowledgement on condition of the pump
check LSB-bus connection, check sensor

293150 E/A-Modul 2: instruments operators cab signal "KL15OWUW" on operation mode selector switch missing E 1
no operation mode determinable, function of upper and undercarriage partly blocked
check operation mode change-switch connection<>E/A-Modul, signals to entries from E/A-Modul; replace E/A-Modul

293151 E/A-Modul 2: instruments operators cab signal "KL15OW" on operation mode selector switch missing E 1
no operation mode determinable, function of upper and undercarriage partly blocked
check operation mode change-switch connection<>E/A-Modul, signals to entries from E/A-Modul; replace E/A-Modul

293152 E/A-Modul 2: instruments operators cab signal "KL15UW" on operation mode selector switch missing E 1
no operation mode determinable, function of upper and undercarriage partly blocked
check operation mode change-switch connection<>E/A-Modul, signals to entries from E/A-Modul; replace E/A-Modul

293153 E/A-Modul 2: instruments operators cab sig. "KL15OW" or "KL15UW" on op. type selector switch missing E 1
no operation mode determinable, function of upper and undercarriage partly blocked
check operation mode change-switch connection<>E/A-Modul, signals to entries from E/A-Modul; replace E/A-Modul

293500 E/A-Modul 2: control heating/air conditioning servo-motor heating, circulated/fresh air or screen/foot erroneous E 1
servo motor relays a high signal to the diagnosis output
check water valve and air flaps of the heating or check servo motor

294190 E/A-Modul 2: LSB-bus participant ZE missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

294191 E/A-Modul 2: LSB-bus participant E/A-Modul 1 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

294193 E/A-Modul 2: LSB-bus participant E/A-Modul 3 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

294194 E/A-Modul 2: LSB-bus participant E/A-Modul 4 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

002389508 155
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

294195 E/A-Modul 2: LSB-bus participant E/A-Modul 5 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

294943 E/A-Modul 2: control optional device no signal from boom sensor in support E 1
control indicator for boom support flashing
check LSB-bus connection, check sensor

295050 E/A-Modul 2: operation engine no engine start possible as engine already recognized as ON B
no start signal on engine
check signals Kl50 ignition start switch and D+ alternator

295055 E/A-Modul 2: operation engine STOP, ignition operators cab in upper-carriage operation mode B
engine stop in upper-carriage operation mode
check switch position ignition start switch in driver's cab

295056 E/A-Modul 2: operation engine STOP, ignition operators cab in under-carriage operation mode B
engine stop in undercarriage operation mode
check switch position ignition start switch in crane cab

295059 E/A-Modul 2: operation engine no start, CAN-connection E/A-Modul <-> engine elec. malfunc B
no engine start possible from crane operators cab
eliminate error in CAN-bus system

295060 E/A-Modul 2: operation engine no start, gears not in N B


engine start not possible
switch transmission to neutral (N)

295061 E/A-Modul 2: operation engine no start, no operation mode recognised B


engine start not possible
check operation modes selection switch in driver's cab

295062 E/A-Modul 2: operation engine no start, ignition upper/under-carriage switched on B


engine start not possible
check switch position ignition start switch in crane cab and driver's cab

295063 E/A-Modul 2: operation engine no start, engine-STOP-key activated in right support unit B
engine start not possible
check key

002389508 156
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

295064 E/A-Modul 2: operation engine no start, engine-STOP-key activated in left support unit B
engine start not possible
check key

295065 E/A-Modul 2: operation engine no start, key activated in support unit B


engine start not possible
check key

295066 E/A-Modul 2: operation engine no start, operation modes-change switch on under-carriage B


engine start not possible
check switch position ignition start switch in crane cab

295067 E/A-Modul 2: operation engine no start, operation modes-change switch on upper-carriage B


engine start not possible
check switch position ignition start switch in driver's cab

295068 E/A-Modul 2: operation engine no start, signal to op. mode-change switch"Kl15OWUW" missing B
engine start not possible
check operation modes selection switch in driver's cab

295069 E/A-Modul 2: operation engine no start, signal to op. mode-change switch"Kl15OW" missing B
engine start not possible
check operation modes selection switch in driver's cab

295070 E/A-Modul 2: operation engine no start, signal to op. mode-change switch"Kl15UW" missing B
engine start not possible
check operation modes selection switch in driver's cab

295079 E/A-Modul 2: operation engine support box-operation mode prevented: gears not in neutral B
no switch-over, support unit blocked
switch transmission to neutral (N)

295080 E/A-Modul 2: operation engine travel operation not possible when key activated on support box B
switch-over results
check support unit keys

295500 E/A-Modul 2: operation axle suspension function simultaneously ON and OFF B


function is not carried out
do not simultaneously activate contrasting function keys

002389508 157
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

295511 E/A-Modul 2: operation axle suspension unauthorised switching on of function B


function is not carried out
start engine and repeat operation

295513 E/A-Modul 2: operation axle suspension unauthorised function activation B


function is not carried out
start engine and repeat operation

295900 E/A-Modul 2: operation longitudinal lock function simultaneously ON and OFF B


function is not carried out
do not simultaneously activate contrasting function keys

295911 E/A-Modul 2: operation longitudinal lock unauthorised switching on of function B


function is not carried out
start engine and repeat operation

295912 E/A-Modul 2: operation longitudinal lock unauthorised switching off of function B


function is not carried out
start engine and repeat operation

295913 E/A-Modul 2: operation longitudinal lock unauthorised function activation B


function is not carried out
start engine and repeat operation

295914 E/A-Modul 2: operation longitudinal lock activation of function without operation mode B
function is not carried out
start engine and repeat operation

296000 E/A-Modul 2: operation transversal lock function simultaneously ON and OFF B


function is not carried out
do not simultaneously activate contrasting function keys

296011 E/A-Modul 2: operation transversal lock unauthorised switching on of function B


function is not carried out
start engine and repeat operation

296012 E/A-Modul 2: operation transversal lock unauthorised switching off of function B


function is not carried out
start engine and repeat operation

002389508 158
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

296013 E/A-Modul 2: operation transversal lock unauthorised function activation B


function is not carried out
start engine and repeat operation

296014 E/A-Modul 2: operation transversal lock activation of function without operation mode B
function is not carried out
start engine and repeat operation

296300 E/A-Modul 2: operation steering front axle function simultaneously ON and OFF B
function is not carried out
do not simultaneously activate contrasting function keys

296313 E/A-Modul 2: operation steering front axle unauthorised function activation B


function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram), start engine and repeat operation

296666 E/A-Modul 2: operation hydraulics/second. power outputs hyd. crane system pump not engaged as compr. air supply too low B

296777 E/A-Modul 2: operation off-road gear off-road gear and transfer box free B
function is not carried out
do not disconnect transfer case in off-road gear ON or off-road gear not ON with disconnection of transfer gear

361001 E/A-Modul 3: system error OS-C167 initialising error processor-register erroneous E 2


error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

361002 E/A-Modul 3: system error OS-C167 initialising error test total in EPROM/FLASH erroneous E 2
error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

361006 E/A-Modul 3: system error OS-C167 initialising error RAM erroneous E 2


error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

361013 E/A-Modul 3: system error OS-C167 test total in EPROM/FLASH erroneous E 2


error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

002389508 159
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

361016 E/A-Modul 3: system error OS-C167 system-, driver-watchdog expired E 2


error indication on display
note error report, ignition On/Off, with regular occurrence --> notify after-sales service

361068 E/A-Modul 3: system error OS-C167 impermissible interrupt E 2


error indication on display
note error report, ignition On/Off, with regular occurrence --> notify after-sales service

361080 E/A-Modul 3: system error OS-C167 fatal internal software error E 2


error indication on display
note error report, ignition On/Off, with regular occurrence --> notify after-sales service

361082 E/A-Modul 3: system error OS-C167 hardware-watchdog erroneous E 2


error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

372052 E/A-Modul 3: input/output DEA0 output open, to low load, short circuit to supply voltage X633:17 U-75.2 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

372053 E/A-Modul 3: input/output DEA0 transistor current supply insufficient or missing X633:17 U-75.2 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

372054 E/A-Modul 3: input/output DEA0 short circuit to supply voltage X633:17 U-75.2 E 1
error report on display
check output for short, if necessary replace E/A-Modul

372055 E/A-Modul 3: input/output DEA0 excessive temperature, short circuit to ground or overload X633:17 U-75.2 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

372152 E/A-Modul 3: input/output DEA1 output open, to low load, short circuit to supply voltage X633:15 U-75.3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

372153 E/A-Modul 3: input/output DEA1 transistor current supply insufficient or missing X633:15 U-75.3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

002389508 160
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

372154 E/A-Modul 3: input/output DEA1 short circuit to supply voltage X633:15 U-75.3 E 1
error report on display
check output for short, if necessary replace E/A-Modul

372155 E/A-Modul 3: input/output DEA1 excessive temperature, short circuit to ground or overload X633:15 U-75.3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

372252 E/A-Modul 3: input/output DEA2 output open, to low load, short circuit to supply voltage X633:13 U-75.3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

372253 E/A-Modul 3: input/output DEA2 transistor current supply insufficient or missing X633:13 U-75.3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

372254 E/A-Modul 3: input/output DEA2 short circuit to supply voltage X633:13 U-75.3 E 1
error report on display
check output for short, if necessary replace E/A-Modul

372255 E/A-Modul 3: input/output DEA2 excessive temperature, short circuit to ground or overload X633:13 U-75.3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

372352 E/A-Modul 3: input/output DEA3 output open, to low load, short circuit to supply voltage X633:11 U-75.4 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

372353 E/A-Modul 3: input/output DEA3 transistor current supply insufficient or missing X633:11 U-75.4 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

372354 E/A-Modul 3: input/output DEA3 short circuit to supply voltage X633:11 U-75.4 E 1
error report on display
check output for short, if necessary replace E/A-Modul

372355 E/A-Modul 3: input/output DEA3 excessive temperature, short circuit to ground or overload X633:11 U-75.4 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

002389508 161
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

372452 E/A-Modul 3: input/output DEA4 output open, to low load, short circuit to supply voltage X633:9 U-75.5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

372453 E/A-Modul 3: input/output DEA4 transistor current supply insufficient or missing X633:9 U-75.5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

372454 E/A-Modul 3: input/output DEA4 short circuit to supply voltage X633:9 U-75.5 E 1
error report on display
check output for short, if necessary replace E/A-Modul

372455 E/A-Modul 3: input/output DEA4 excessive temperature, short circuit to ground or overload X633:9 U-75.5 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

372552 E/A-Modul 3: input/output DEA5 output open, to low load, short circuit to supply voltage X633:7 U-75.6 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

372553 E/A-Modul 3: input/output DEA5 transistor current supply insufficient or missing X633:7 U-75.6 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

372554 E/A-Modul 3: input/output DEA5 short circuit to supply voltage X633:7 U-75.6 E 1
error report on display
check output for short, if necessary replace E/A-Modul

372555 E/A-Modul 3: input/output DEA5 excessive temperature, short circuit to ground or overload X633:7 U-75.6 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

372652 E/A-Modul 3: input/output DEA6 output open, to low load, short circuit to supply voltage X633:5 U-75.7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

372653 E/A-Modul 3: input/output DEA6 transistor current supply insufficient or missing X633:5 U-75.7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

002389508 162
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

372654 E/A-Modul 3: input/output DEA6 short circuit to supply voltage X633:5 U-75.7 E 1
error report on display
check output for short, if necessary replace E/A-Modul

372655 E/A-Modul 3: input/output DEA6 excessive temperature, short circuit to ground or overload X633:5 U-75.7 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

372752 E/A-Modul 3: input/output DEA7 output open, to low load, short circuit to supply voltage X633:3 U-75.7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

372753 E/A-Modul 3: input/output DEA7 transistor current supply insufficient or missing X633:3 U-75.7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

372754 E/A-Modul 3: input/output DEA7 short circuit to supply voltage X633:3 U-75.7 E 1
error report on display
check output for short, if necessary replace E/A-Modul

372755 E/A-Modul 3: input/output DEA7 excessive temperature, short circuit to ground or overload X633:3 U-75.7 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

373017 E/A-Modul 3: current input E0 voltage below required value X632:17 U-99.3 E 1
on both support operating units "E." is flashing on the display for support force front right
check input signal on the E/A-Modul or sensor

373080 E/A-Modul 3: current input E0 short circuit to ground, open line, voltage sensor erroneous X632:17 U-99.3 E 1
on both support operating units "E." is flashing on the display for support force front right
check input signal on the E/A-Modul or sensor

373117 E/A-Modul 3: current input E1 voltage below required value X632:15 U-99.1 E 1
on both support operating units "E." is flashing on the display for support force rear right
check input signal on the E/A-Modul or sensor

373180 E/A-Modul 3: current input E1 short circuit to ground, open line, voltage sensor erroneous X632:15 U-99.1 E 1
on both support operating units "E." is flashing on the display for support force rear right
check input signal on the E/A-Modul or sensor

002389508 163
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

373217 E/A-Modul 3: current input E2 voltage below required value X632:13 U-100.6 E 1
both outer LEDs for transversal inclination on both support operating units are flashing
check input signal on the E/A-Modul or sensor

373280 E/A-Modul 3: current input E2 short circuit to ground, open line, voltage sensor erroneous X632:13 U-100.6 E 1
both outer LEDs for transversal inclination on both support operating units are flashing
check input signal on the E/A-Modul or sensor

373317 E/A-Modul 3: current input E3 voltage below required value X632:11 U-100.7 E 1
both outer LEDs for longitudinal inclination are flashing on both support units
check input signal on the E/A-Modul or sensor

373380 E/A-Modul 3: current input E3 short circuit to ground, open line, voltage sensor erroneous X632:11 U-100.7 E 1
both outer LEDs for longitudinal inclination are flashing on both support units
check input signal on the E/A-Modul or sensor

373782 E/A-Modul 3: voltage input E7 short circuit to ground, open line, constant current 10 mA incorrect X632:4 U-60.7 E 1
symbol for diesel tank is flashing on the display unit, as are 3 question marks on monitor in uppercarriage
check input signal on the E/A-Modul or sensor

373783 E/A-Modul 3: voltage input E7 short circuit to supply voltage, open line, lack of voltage X632:4 U-60.7 E 1
symbol for diesel tank is flashing on the display unit, as are 3 question marks on monitor in uppercarriage
check input signal on the E/A-Modul or sensor

379052 E/A-Modul 3: output A0 output open, to low load, short circuit to supply voltage X633:18 U-76.2 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

379053 E/A-Modul 3: output A0 transistor current supply insufficient or missing X633:18 U-76.2 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

379054 E/A-Modul 3: output A0 short circuit to supply voltage X633:18 U-76.2 E 1


error report on display
check output for short, if necessary replace E/A-Modul

379055 E/A-Modul 3: output A0 excessive temperature, short circuit to ground or overload X633:18 U-76.2 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

002389508 164
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

379152 E/A-Modul 3: output A1 output open, to low load, short circuit to supply voltage X633:16 U-76.2 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

379153 E/A-Modul 3: output A1 transistor current supply insufficient or missing X633:16 U-76.2 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

379154 E/A-Modul 3: output A1 short circuit to supply voltage X633:16 U-76.2 E 1


error report on display
check output for short, if necessary replace E/A-Modul

379155 E/A-Modul 3: output A1 excessive temperature, short circuit to ground or overload X633:16 U-76.2 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

379250 E/A-Modul 3: bridge output A2 short circuit to ground, junction not supplied X633:14 U-76.3 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul

379251 E/A-Modul 3: bridge output A2 short circuit to supply voltage, excessive temperature X633:14 U-76.3 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul

379252 E/A-Modul 3: bridge output A2 output open, to low load, short circuit to supply voltage X633:14 U-76.3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

379253 E/A-Modul 3: bridge output A2 transistor current supply insufficient or missing X633:14 U-76.3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

379254 E/A-Modul 3: bridge output A2 short circuit to supply voltage X633:14 U-76.3 E 1
error report on display
check output for short, if necessary replace E/A-Modul

379255 E/A-Modul 3: bridge output A2 excessive temperature, short circuit to ground or overload X633:14 U-76.3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

002389508 165
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

379350 E/A-Modul 3: bridge output A3 short circuit to ground, junction not supplied X633:12 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul

379351 E/A-Modul 3: bridge output A3 short circuit to supply voltage, excessive temperature X633:12 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul

379352 E/A-Modul 3: bridge output A3 output open, to low load, short circuit to supply voltage X633:12 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

379353 E/A-Modul 3: bridge output A3 transistor current supply insufficient or missing X633:12 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

379354 E/A-Modul 3: bridge output A3 short circuit to supply voltage X633:12 E 1


error report on display
check output for short, if necessary replace E/A-Modul

379355 E/A-Modul 3: bridge output A3 excessive temperature, short circuit to ground or overload X633:12 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

383501 E/A-Modul 3: SPI-support unit right Faulty data transfer E/A-module<>unit (time exceeded) X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

383502 E/A-Modul 3: SPI-support unit right Serious system error to SPI-connection (interface) X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

383503 E/A-Modul 3: SPI-support unit right break in line or short circuit to supply voltage X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary

383504 E/A-Modul 3: SPI-support unit right break in line or short circuit to ground X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary

002389508 166
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

383506 E/A-Modul 3: SPI-support unit right Data transfer faulty (faulty check byte) X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
suppress EMV- interference

383507 E/A-Modul 3: SPI-support unit right Unit faulty/missing, incorrect unit inserted (ID) X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
check periphery and replace if necessary, check Software version, check EMV- interference

383508 E/A-Modul 3: SPI-support unit right Data transfer faulty (incorrect number of data bytes received) X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

383900 E/A-Modul 3: Control operating unit (SPI) Faulty initialisation data connection E/A-module<>unit X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

383902 E/A-Modul 3: Control operating unit (SPI) Serious system error to SPI-connection (interface) X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

383905 E/A-Modul 3: Control operating unit (SPI) Initialisation error, resetting inputs/outputs faulty X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
check wiring, check periphery and replace if necessary, check E/A-Modul and replace if necessary

383907 E/A-Modul 3: Control operating unit (SPI) Unit faulty/missing, incorrect unit inserted (ID) X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
connect functional periphery unit, system then eliminates error independently

383908 E/A-Modul 3: Control operating unit (SPI) Data transfer faulty (incorrect number of data bytes received) X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

384050 E/A-Modul 3: LSB-B participant address 0 reports an incorrect sensor type X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

384051 E/A-Modul 3: LSB-B participant address 0 was not configured for the block transfer X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

002389508 167
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

384053 E/A-Modul 3: LSB-B participant address 0 no longer reports or withdrawn during running period X633:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

384054 E/A-Modul 3: LSB-B participant address 0 Features other settings (parameters) as pre-entered set values X633:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

384064 E/A-Modul 3: LSB-B participant address 0 reports tolerable error in self-test X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

384065 E/A-Modul 3: LSB-B participant address 0 reports intolerable error in self-test X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

384066 E/A-Modul 3: LSB-B participant address 0 with software version, that is no longer compatible X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

384067 E/A-Modul 3: LSB-B participant address 0 supports no download function X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

384150 E/A-Modul 3: LSB-B participant address 1 reports an incorrect sensor type X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

384151 E/A-Modul 3: LSB-B participant address 1 was not configured for the block transfer X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

384153 E/A-Modul 3: LSB-B participant address 1 no longer reports or withdrawn during running period X633:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

384154 E/A-Modul 3: LSB-B participant address 1 Features other settings (parameters) as pre-entered set values X633:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

002389508 168
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

384164 E/A-Modul 3: LSB-B participant address 1 reports tolerable error in self-test X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

384165 E/A-Modul 3: LSB-B participant address 1 reports intolerable error in self-test X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

384166 E/A-Modul 3: LSB-B participant address 1 with software version, that is no longer compatible X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

384167 E/A-Modul 3: LSB-B participant address 1 supports no download function X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

384250 E/A-Modul 3: LSB-B participant address 2 reports an incorrect sensor type X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

384251 E/A-Modul 3: LSB-B participant address 2 was not configured for the block transfer X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

384253 E/A-Modul 3: LSB-B participant address 2 no longer reports or withdrawn during running period X633:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

384254 E/A-Modul 3: LSB-B participant address 2 Features other settings (parameters) as pre-entered set values X633:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

384264 E/A-Modul 3: LSB-B participant address 2 reports tolerable error in self-test X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

384265 E/A-Modul 3: LSB-B participant address 2 reports intolerable error in self-test X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

002389508 169
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

384266 E/A-Modul 3: LSB-B participant address 2 with software version, that is no longer compatible X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

384267 E/A-Modul 3: LSB-B participant address 2 supports no download function X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

384350 E/A-Modul 3: LSB-B participant address 3 reports an incorrect sensor type X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

384351 E/A-Modul 3: LSB-B participant address 3 was not configured for the block transfer X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

384353 E/A-Modul 3: LSB-B participant address 3 no longer reports or withdrawn during running period X633:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

384354 E/A-Modul 3: LSB-B participant address 3 Features other settings (parameters) as pre-entered set values X633:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

384364 E/A-Modul 3: LSB-B participant address 3 reports tolerable error in self-test X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

384365 E/A-Modul 3: LSB-B participant address 3 reports intolerable error in self-test X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

384366 E/A-Modul 3: LSB-B participant address 3 with software version, that is no longer compatible X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

384367 E/A-Modul 3: LSB-B participant address 3 supports no download function X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

002389508 170
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

384450 E/A-Modul 3: LSB-B participant address 4 reports an incorrect sensor type X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

384451 E/A-Modul 3: LSB-B participant address 4 was not configured for the block transfer X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

384453 E/A-Modul 3: LSB-B participant address 4 no longer reports or withdrawn during running period X633:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

384454 E/A-Modul 3: LSB-B participant address 4 Features other settings (parameters) as pre-entered set values X633:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

384464 E/A-Modul 3: LSB-B participant address 4 reports tolerable error in self-test X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

384465 E/A-Modul 3: LSB-B participant address 4 reports intolerable error in self-test X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

384466 E/A-Modul 3: LSB-B participant address 4 with software version, that is no longer compatible X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

384467 E/A-Modul 3: LSB-B participant address 4 supports no download function X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

384550 E/A-Modul 3: LSB-B participant address 5 reports an incorrect sensor type X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

384551 E/A-Modul 3: LSB-B participant address 5 was not configured for the block transfer X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

002389508 171
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

384553 E/A-Modul 3: LSB-B participant address 5 no longer reports or withdrawn during running period X633:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

384554 E/A-Modul 3: LSB-B participant address 5 Features other settings (parameters) as pre-entered set values X633:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

384564 E/A-Modul 3: LSB-B participant address 5 reports tolerable error in self-test X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

384565 E/A-Modul 3: LSB-B participant address 5 reports intolerable error in self-test X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

384566 E/A-Modul 3: LSB-B participant address 5 with software version, that is no longer compatible X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

384567 E/A-Modul 3: LSB-B participant address 5 supports no download function X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

384650 E/A-Modul 3: LSB-B participant address 6 reports an incorrect sensor type X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

384651 E/A-Modul 3: LSB-B participant address 6 was not configured for the block transfer X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

384653 E/A-Modul 3: LSB-B participant address 6 no longer reports or withdrawn during running period X633:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

384654 E/A-Modul 3: LSB-B participant address 6 Features other settings (parameters) as pre-entered set values X633:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

002389508 172
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

384664 E/A-Modul 3: LSB-B participant address 6 reports tolerable error in self-test X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

384665 E/A-Modul 3: LSB-B participant address 6 reports intolerable error in self-test X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

384666 E/A-Modul 3: LSB-B participant address 6 with software version, that is no longer compatible X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

384667 E/A-Modul 3: LSB-B participant address 6 supports no download function X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

387252 E/A-Modul 3: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X633:4/6 U-46.6/46.5 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor

387255 E/A-Modul 3: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X633:4/6 U-46.6/46.5 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

387256 E/A-Modul 3: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X633:4/6 U-46.6/46.5 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

387257 E/A-Modul 3: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X633:4/6 U-46.6/46.5 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part

387258 E/A-Modul 3: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X633:4/6 U-46.6/46.5 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors

387259 E/A-Modul 3: Control data transfer LSB-B recognised communication breakdown in bus X633:4/6 U-46.6/46.5 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network

002389508 173
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

387260 E/A-Modul 3: Control data transfer LSB-B driver error: no order to carry out X633:4/6 U-46.6/46.5 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software

387261 E/A-Modul 3: Control data transfer LSB-B driver error: undefined message appears X633:4/6 U-46.6/46.5 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination

387262 E/A-Modul 3: Control data transfer LSB-B driver error: initialising error X633:4/6 U-46.6/46.5 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination

392830 E/A-Modul 3: control supports location coding for right support unit erroneous (set value = 0) E 2
support functions are blocked
check line connection to E/A-Modul, check ground connection from signal, replace E/A-Modul

392832 E/A-Modul 3: control supports right support unit key sticking or activated after switching on E 1
right support blocked
check/unplug/replace support operating unit release activated key

394190 E/A-Modul 3: LSB-bus participant ZE missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

394191 E/A-Modul 3: LSB-bus participant E/A-Modul 1 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

394192 E/A-Modul 3: LSB-bus participant E/A-Modul 2 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

394194 E/A-Modul 3: LSB-bus participant E/A-Modul 4 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

394195 E/A-Modul 3: LSB-bus participant E/A-Modul 5 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

002389508 174
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

396408 E/A-Modul 3: operation supports unauthorised operation from upper-carriage B


function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

396409 E/A-Modul 3: operation supports unauthorised operation from under-carriage B


function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

396440 E/A-Modul 3: operation supports simultaneous UP and DOWN operation of support control unit B
function is not carried out
actuate UP key or DOWN key of the respective support operating unit, start test program support service unit

396441 E/A-Modul 3: operation supports simultaneous IN and OUT operation of support control unit B
function is not carried out
actuate OFF key or ON key of the respective support operating unit, start test program support operating unit

396442 E/A-Modul 3: operation supports simultaneous UP and DOWN operation on upper-carriage monitor B
function is not carried out
actuate UP key or DOWN key of the respective support operating unit, start test program support service unit

396443 E/A-Modul 3: operation supports simultaneous IN and OUT operation on upper-carriage monitor B
function is not carried out
actuate OFF key or ON key of the respective support operating unit, start test program support operating unit

396444 E/A-Modul 3: operation supports simultaneous left and right operation of support control unit B
function is not carried out
actuate support from only one operating position, start test program support operating unit

396445 E/A-Modul 3: operation supports simultaneous operation of support control unit and upper-carriage B
function is not carried out
actuate support from only one operating position, start test program support operating unit

396446 E/A-Modul 3: operation supports simultaneous operation of support control unit and upper-carriage B
function is not carried out
actuate support from only one operating position, start test program support operating unit

396447 E/A-Modul 3: operation supports operation of support control unit with travel direction D engaged B
function is not carried out
switch transmission to neutral (N)

002389508 175
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

396448 E/A-Modul 3: operation supports operation of support control unit with travel direction R engaged B
function is not carried out
switch transmission to neutral (N)

396449 E/A-Modul 3: operation supports op. of upper-carriage monitor with travel direction D engaged B
function is not carried out
switch transmission to neutral (N)

396450 E/A-Modul 3: operation supports operation of upper-carriage-monitor R B


function is not carried out
switch transmission to neutral (N)

396451 E/A-Modul 3: operation supports unauthorised activation of right support control unit key B
right support blocked
release activated key after having authorized function through hand- key

399890 E/A-Modul 3: operation diagnosis system test program not executable as engine is not OFF B
function is not carried out
shut down engine

399892 E/A-Modul 3: operation diagnosis system test program not executable as not in under-carriage op. mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode

461001 E/A-Modul 4: system error OS-C167 initialising error processor-register erroneous E 2


error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

461002 E/A-Modul 4: system error OS-C167 initialising error test total in EPROM/FLASH erroneous E 2
error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

461006 E/A-Modul 4: system error OS-C167 initialising error RAM erroneous E 2


error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

461013 E/A-Modul 4: system error OS-C167 test total in EPROM/FLASH erroneous E 2


error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

002389508 176
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

461016 E/A-Modul 4: system error OS-C167 system-, driver-watchdog expired E 2


error indication on display
note error report, ignition On/Off, with regular occurrence --> notify after-sales service

461068 E/A-Modul 4: system error OS-C167 impermissible interrupt E 2


error indication on display
note error report, ignition On/Off, with regular occurrence --> notify after-sales service

461080 E/A-Modul 4: system error OS-C167 fatal internal software error E 2


error indication on display
note error report, ignition On/Off, with regular occurrence --> notify after-sales service

461082 E/A-Modul 4: system error OS-C167 hardware-watchdog erroneous E 2


error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

472052 E/A-Modul 4: input/output DEA0 output open, to low load, short circuit to supply voltage X643:17 U-74.2 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

472053 E/A-Modul 4: input/output DEA0 transistor current supply insufficient or missing X643:17 U-74.2 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

472054 E/A-Modul 4: input/output DEA0 short circuit to supply voltage X643:17 U-74.2 E 1
error report on display
check output for short, if necessary replace E/A-Modul

472055 E/A-Modul 4: input/output DEA0 excessive temperature, short circuit to ground or overload X643:17 U-74.2 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

472152 E/A-Modul 4: input/output DEA1 output open, to low load, short circuit to supply voltage X643:15 U-74.3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

472153 E/A-Modul 4: input/output DEA1 transistor current supply insufficient or missing X643:15 U-74.3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

002389508 177
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

472154 E/A-Modul 4: input/output DEA1 short circuit to supply voltage X643:15 U-74.3 E 1
error report on display
check output for short, if necessary replace E/A-Modul

472155 E/A-Modul 4: input/output DEA1 excessive temperature, short circuit to ground or overload X643:15 U-74.3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

472252 E/A-Modul 4: input/output DEA2 output open, to low load, short circuit to supply voltage X643:13 U-74.3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

472253 E/A-Modul 4: input/output DEA2 transistor current supply insufficient or missing X643:13 U-74.3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

472254 E/A-Modul 4: input/output DEA2 short circuit to supply voltage X643:13 U-74.3 E 1
error report on display
check output for short, if necessary replace E/A-Modul

472255 E/A-Modul 4: input/output DEA2 excessive temperature, short circuit to ground or overload X643:13 U-74.3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

472352 E/A-Modul 4: input/output DEA3 output open, to low load, short circuit to supply voltage X643:11 U-74.4 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

472353 E/A-Modul 4: input/output DEA3 transistor current supply insufficient or missing X643:11 U-74.4 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

472354 E/A-Modul 4: input/output DEA3 short circuit to supply voltage X643:11 U-74.4 E 1
error report on display
check output for short, if necessary replace E/A-Modul

472355 E/A-Modul 4: input/output DEA3 excessive temperature, short circuit to ground or overload X643:11 U-74.4 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

002389508 178
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

472452 E/A-Modul 4: input/output DEA4 output open, to low load, short circuit to supply voltage X643:9 U-74.5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

472453 E/A-Modul 4: input/output DEA4 transistor current supply insufficient or missing X643:9 U-74.5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

472454 E/A-Modul 4: input/output DEA4 short circuit to supply voltage X643:9 U-74.5 E 1
error report on display
check output for short, if necessary replace E/A-Modul

472455 E/A-Modul 4: input/output DEA4 excessive temperature, short circuit to ground or overload X643:9 U-74.5 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

472552 E/A-Modul 4: input/output DEA5 output open, to low load, short circuit to supply voltage X643:7 U-74.6 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

472553 E/A-Modul 4: input/output DEA5 transistor current supply insufficient or missing X643:7 U-74.6 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

472554 E/A-Modul 4: input/output DEA5 short circuit to supply voltage X643:7 U-74.6 E 1
error report on display
check output for short, if necessary replace E/A-Modul

472555 E/A-Modul 4: input/output DEA5 excessive temperature, short circuit to ground or overload X643:7 U-74.6 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

472652 E/A-Modul 4: input/output DEA6 output open, to low load, short circuit to supply voltage X643:5 U-74.7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

472653 E/A-Modul 4: input/output DEA6 transistor current supply insufficient or missing X643:5 U-74.7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

002389508 179
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

472654 E/A-Modul 4: input/output DEA6 short circuit to supply voltage X643:5 U-74.7 E 1
error report on display
check output for short, if necessary replace E/A-Modul

472655 E/A-Modul 4: input/output DEA6 excessive temperature, short circuit to ground or overload X643:5 U-74.7 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

472752 E/A-Modul 4: input/output DEA7 output open, to low load, short circuit to supply voltage X643:3 U-74.7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

472753 E/A-Modul 4: input/output DEA7 transistor current supply insufficient or missing X643:3 U-74.7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

472754 E/A-Modul 4: input/output DEA7 short circuit to supply voltage X643:3 U-74.7 E 1
error report on display
check output for short, if necessary replace E/A-Modul

472755 E/A-Modul 4: input/output DEA7 excessive temperature, short circuit to ground or overload X643:3 U-74.7 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

473017 E/A-Modul 4: current input E0 voltage below required value X642:17 U-99.5 E 1
on both support operating units "E." is flashing on the display for support force front left
check input signal on the E/A-Modul or sensor

473080 E/A-Modul 4: current input E0 short circuit to ground, open line, voltage sensor erroneous X642:17 U-99.5 E 1
on both support operating units "E." is flashing on the display for support force front left
check input signal on the E/A-Modul or sensor

473117 E/A-Modul 4: current input E1 voltage below required value X642:15 U-99.7 E 1
on both support operating units "E." is flashing on the display for support force rear left
check input signal on the E/A-Modul or sensor

473180 E/A-Modul 4: current input E1 short circuit to ground, open line, voltage sensor erroneous X642:15 U-99.7 E 1
on both support operating units "E." is flashing on the display for support force rear left
check input signal on the E/A-Modul or sensor

002389508 180
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

479052 E/A-Modul 4: output A0 output open, to low load, short circuit to supply voltage X643:18 U-73.6 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

479053 E/A-Modul 4: output A0 transistor current supply insufficient or missing X643:18 U-73.6 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

479054 E/A-Modul 4: output A0 short circuit to supply voltage X643:18 U-73.6 E 1


error report on display
check output for short, if necessary replace E/A-Modul

479055 E/A-Modul 4: output A0 excessive temperature, short circuit to ground or overload X643:18 U-73.6 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

479152 E/A-Modul 4: output A1 output open, to low load, short circuit to supply voltage X643:16 U-73.5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

479153 E/A-Modul 4: output A1 transistor current supply insufficient or missing X643:16 U-73.5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

479154 E/A-Modul 4: output A1 short circuit to supply voltage X643:16 U-73.5 E 1


error report on display
check output for short, if necessary replace E/A-Modul

479155 E/A-Modul 4: output A1 excessive temperature, short circuit to ground or overload X643:16 U-73.5 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

479250 E/A-Modul 4: bridge output A2 short circuit to ground, junction not supplied X643:14 U-73.7 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul

479251 E/A-Modul 4: bridge output A2 short circuit to supply voltage, excessive temperature X643:14 U-73.7 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul

002389508 181
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

479252 E/A-Modul 4: bridge output A2 output open, to low load, short circuit to supply voltage X643:14 U-73.7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

479253 E/A-Modul 4: bridge output A2 transistor current supply insufficient or missing X643:14 U-73.7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

479254 E/A-Modul 4: bridge output A2 short circuit to supply voltage X643:14 U-73.7 E 1
error report on display
check output for short, if necessary replace E/A-Modul

479255 E/A-Modul 4: bridge output A2 excessive temperature, short circuit to ground or overload X643:14 U-73.7 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

479350 E/A-Modul 4: bridge output A3 short circuit to ground, junction not supplied X643:12 U-73.7 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul

479351 E/A-Modul 4: bridge output A3 short circuit to supply voltage, excessive temperature X643:12 U-73.7 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul

479352 E/A-Modul 4: bridge output A3 output open, to low load, short circuit to supply voltage X643:12 U-73.7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

479353 E/A-Modul 4: bridge output A3 transistor current supply insufficient or missing X643:12 U-73.7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

479354 E/A-Modul 4: bridge output A3 short circuit to supply voltage X643:12 U-73.7 E 1
error report on display
check output for short, if necessary replace E/A-Modul

479355 E/A-Modul 4: bridge output A3 excessive temperature, short circuit to ground or overload X643:12 U-73.7 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

002389508 182
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

483601 E/A-Modul 4: SPI-support unit left Faulty data transfer E/A-module<>unit (time exceeded) X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

483602 E/A-Modul 4: SPI-support unit left Serious system error to SPI-connection (interface) X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

483603 E/A-Modul 4: SPI-support unit left break in line or short circuit to supply voltage X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary

483604 E/A-Modul 4: SPI-support unit left break in line or short circuit to ground X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary

483606 E/A-Modul 4: SPI-support unit left Data transfer faulty (faulty check byte) X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
suppress EMV- interference

483607 E/A-Modul 4: SPI-support unit left Unit faulty/missing, incorrect unit inserted (ID) X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
check periphery and replace if necessary, check Software version, check EMV- interference

483608 E/A-Modul 4: SPI-support unit left Data transfer faulty (incorrect number of data bytes received) X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

483900 E/A-Modul 4: Control operating unit (SPI) Faulty initialisation data connection E/A-module<>unit X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

483902 E/A-Modul 4: Control operating unit (SPI) Serious system error to SPI-connection (interface) X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

483905 E/A-Modul 4: Control operating unit (SPI) Initialisation error, resetting inputs/outputs faulty X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
check wiring, check periphery and replace if necessary, check E/A-Modul and replace if necessary

002389508 183
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

483907 E/A-Modul 4: Control operating unit (SPI) Unit faulty/missing, incorrect unit inserted (ID) X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
connect functional periphery unit, system then eliminates error independently

483908 E/A-Modul 4: Control operating unit (SPI) Data transfer faulty (incorrect number of data bytes received) X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul

484050 E/A-Modul 4: LSB-B participant address 0 reports an incorrect sensor type X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

484051 E/A-Modul 4: LSB-B participant address 0 was not configured for the block transfer X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

484053 E/A-Modul 4: LSB-B participant address 0 no longer reports or withdrawn during running period X643:4/6 U-46.8/46.7 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

484054 E/A-Modul 4: LSB-B participant address 0 Features other settings (parameters) as pre-entered set values X643:4/6 U-46.8/46.7 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

484064 E/A-Modul 4: LSB-B participant address 0 reports tolerable error in self-test X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

484065 E/A-Modul 4: LSB-B participant address 0 reports intolerable error in self-test X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

484066 E/A-Modul 4: LSB-B participant address 0 with software version, that is no longer compatible X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

484067 E/A-Modul 4: LSB-B participant address 0 supports no download function X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

002389508 184
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

484150 E/A-Modul 4: LSB-B participant address 1 reports an incorrect sensor type X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

484151 E/A-Modul 4: LSB-B participant address 1 was not configured for the block transfer X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

484153 E/A-Modul 4: LSB-B participant address 1 no longer reports or withdrawn during running period X643:4/6 U-46.8/46.7 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

484154 E/A-Modul 4: LSB-B participant address 1 Features other settings (parameters) as pre-entered set values X643:4/6 U-46.8/46.7 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

484164 E/A-Modul 4: LSB-B participant address 1 reports tolerable error in self-test X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

484165 E/A-Modul 4: LSB-B participant address 1 reports intolerable error in self-test X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

484166 E/A-Modul 4: LSB-B participant address 1 with software version, that is no longer compatible X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

484167 E/A-Modul 4: LSB-B participant address 1 supports no download function X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

484250 E/A-Modul 4: LSB-B participant address 2 reports an incorrect sensor type X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

484251 E/A-Modul 4: LSB-B participant address 2 was not configured for the block transfer X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

002389508 185
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

484253 E/A-Modul 4: LSB-B participant address 2 no longer reports or withdrawn during running period X643:4/6 U-46.8/46.7 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

484254 E/A-Modul 4: LSB-B participant address 2 Features other settings (parameters) as pre-entered set values X643:4/6 U-46.8/46.7 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

484264 E/A-Modul 4: LSB-B participant address 2 reports tolerable error in self-test X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

484265 E/A-Modul 4: LSB-B participant address 2 reports intolerable error in self-test X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

484266 E/A-Modul 4: LSB-B participant address 2 with software version, that is no longer compatible X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

484267 E/A-Modul 4: LSB-B participant address 2 supports no download function X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

484350 E/A-Modul 4: LSB-B participant address 3 reports an incorrect sensor type X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

484351 E/A-Modul 4: LSB-B participant address 3 was not configured for the block transfer X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

484353 E/A-Modul 4: LSB-B participant address 3 no longer reports or withdrawn during running period X643:4/6 U-46.8/46.7 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

484354 E/A-Modul 4: LSB-B participant address 3 Features other settings (parameters) as pre-entered set values X643:4/6 U-46.8/46.7 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

002389508 186
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

484364 E/A-Modul 4: LSB-B participant address 3 reports tolerable error in self-test X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

484365 E/A-Modul 4: LSB-B participant address 3 reports intolerable error in self-test X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

484366 E/A-Modul 4: LSB-B participant address 3 with software version, that is no longer compatible X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

484367 E/A-Modul 4: LSB-B participant address 3 supports no download function X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

484450 E/A-Modul 4: LSB-B participant address 4 reports an incorrect sensor type X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

484451 E/A-Modul 4: LSB-B participant address 4 was not configured for the block transfer X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

484453 E/A-Modul 4: LSB-B participant address 4 no longer reports or withdrawn during running period X643:4/6 U-46.8/46.7 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

484454 E/A-Modul 4: LSB-B participant address 4 Features other settings (parameters) as pre-entered set values X643:4/6 U-46.8/46.7 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

484464 E/A-Modul 4: LSB-B participant address 4 reports tolerable error in self-test X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

484465 E/A-Modul 4: LSB-B participant address 4 reports intolerable error in self-test X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

002389508 187
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

484466 E/A-Modul 4: LSB-B participant address 4 with software version, that is no longer compatible X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

484467 E/A-Modul 4: LSB-B participant address 4 supports no download function X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

484550 E/A-Modul 4: LSB-B participant address 5 reports an incorrect sensor type X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

484551 E/A-Modul 4: LSB-B participant address 5 was not configured for the block transfer X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

484553 E/A-Modul 4: LSB-B participant address 5 no longer reports or withdrawn during running period X643:4/6 U-46.8/46.7 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

484554 E/A-Modul 4: LSB-B participant address 5 Features other settings (parameters) as pre-entered set values X643:4/6 U-46.8/46.7 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

484564 E/A-Modul 4: LSB-B participant address 5 reports tolerable error in self-test X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

484565 E/A-Modul 4: LSB-B participant address 5 reports intolerable error in self-test X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

484566 E/A-Modul 4: LSB-B participant address 5 with software version, that is no longer compatible X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

484567 E/A-Modul 4: LSB-B participant address 5 supports no download function X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

002389508 188
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

484650 E/A-Modul 4: LSB-B participant address 6 reports an incorrect sensor type X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

484651 E/A-Modul 4: LSB-B participant address 6 was not configured for the block transfer X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

484653 E/A-Modul 4: LSB-B participant address 6 no longer reports or withdrawn during running period X643:4/6 U-46.8/46.7 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

484654 E/A-Modul 4: LSB-B participant address 6 Features other settings (parameters) as pre-entered set values X643:4/6 U-46.8/46.7 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

484664 E/A-Modul 4: LSB-B participant address 6 reports tolerable error in self-test X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

484665 E/A-Modul 4: LSB-B participant address 6 reports intolerable error in self-test X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

484666 E/A-Modul 4: LSB-B participant address 6 with software version, that is no longer compatible X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

484667 E/A-Modul 4: LSB-B participant address 6 supports no download function X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

487252 E/A-Modul 4: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X643:4/6 U-46.8/46.7 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor

487255 E/A-Modul 4: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X643:4/6 U-46.8/46.7 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

002389508 189
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

487256 E/A-Modul 4: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X643:4/6 U-46.8/46.7 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

487257 E/A-Modul 4: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X643:4/6 U-46.8/46.7 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part

487258 E/A-Modul 4: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X643:4/6 U-46.8/46.7 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors

487259 E/A-Modul 4: Control data transfer LSB-B recognised communication breakdown in bus X643:4/6 U-46.8/46.7 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network

487260 E/A-Modul 4: Control data transfer LSB-B driver error: no order to carry out X643:4/6 U-46.8/46.7 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software

487261 E/A-Modul 4: Control data transfer LSB-B driver error: undefined message appears X643:4/6 U-46.8/46.7 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination

487262 E/A-Modul 4: Control data transfer LSB-B driver error: initialising error X643:4/6 U-46.8/46.7 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination

492747 E/A-Modul 4: control steering signal from steering pump flow switch erroneous E 1
control indicator for steering pump flashing
check line connections, power supply 10 mA from E/A-Modul; replace sensor or E/A-Modul

492748 E/A-Modul 4: control steering signal from auxiliary steering pump flow switch erroneous E 1
control indicator for auxiliary steering pump flashing
check line connections, power supply 10 mA from E/A-Modul; replace sensor or E/A-Modul

492831 E/A-Modul 4: control supports location coding for left support unit erroneous (set value = 1) E 2
support functions are blocked
check line connection to E/A-Modul, check power supply from signal, replace E/A-Modul

002389508 190
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

492833 E/A-Modul 4: control supports left support unit key sticking or activated after switching on E 1
left support blocked
check/unplug/replace support operating unit release activated key

494190 E/A-Modul 4: LSB-bus participant ZE missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

494191 E/A-Modul 4: LSB-bus participant E/A-Modul 1 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

494192 E/A-Modul 4: LSB-bus participant E/A-Modul 2 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

494193 E/A-Modul 4: LSB-bus participant E/A-Modul 3 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

494195 E/A-Modul 4: LSB-bus participant E/A-Modul 5 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

496100 E/A-Modul 4: operation unlocking rear axle function simultaneously ON and OFF B
function is not carried out
do not simultaneously activate contrasting function keys

496111 E/A-Modul 4: operation unlocking rear axle unauthorised switching on of function B


function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

496112 E/A-Modul 4: operation unlocking rear axle unauthorised switching off of function B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

496113 E/A-Modul 4: operation unlocking rear axle unauthorised function activation B


function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

002389508 191
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

496114 E/A-Modul 4: operation unlocking rear axle activation of function without operation mode B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

496160 E/A-Modul 4: operation unlocking rear axle undefined condition: simultaneously locked and unlocked B
function is not carried out
check unlocking condition, Check locking limit switch and unlocking limit switch

496200 E/A-Modul 4: operation steering rear axle function simultaneously ON and OFF B
function is not carried out
do not simultaneously activate contrasting function keys

496213 E/A-Modul 4: operation steering rear axle unauthorised function activation B


function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

496214 E/A-Modul 4: operation steering rear axle activation of function without operation mode B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

496408 E/A-Modul 4: operation supports unauthorised operation from upper-carriage B


function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

496409 E/A-Modul 4: operation supports unauthorised operation from under-carriage B


function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)

496440 E/A-Modul 4: operation supports simultaneous UP and DOWN operation of support control unit B
function is not carried out
actuate UP key or DOWN key of the respective support operating unit, start test program support service unit

496441 E/A-Modul 4: operation supports simultaneous IN and OUT operation of support control unit B
function is not carried out
actuate OFF key or ON key of the respective support operating unit, start test program support operating unit

496442 E/A-Modul 4: operation supports simultaneous UP and DOWN operation on upper-carriage monitor B
function is not carried out
actuate UP key or DOWN key of the respective support operating unit, start test program support service unit

002389508 192
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

496443 E/A-Modul 4: operation supports simultaneous IN and OUT operation on upper-carriage monitor B
function is not carried out
actuate OFF key or ON key of the respective support operating unit, start test program support operating unit

496444 E/A-Modul 4: operation supports simultaneous left and right operation of support control unit B
function is not carried out
activate support from only one operating position or start test program support operating unit

496445 E/A-Modul 4: operation supports simultaneous operation of support control unit and upper-carriage B
function is not carried out
activate support from only one operating position or start test program support operating unit

496446 E/A-Modul 4: operation supports simultaneous operation of support control unit and upper-carriage B
function is not carried out
activate support from only one operating position or start test program support operating unit

496447 E/A-Modul 4: operation supports operation of support control unit with travel direction D engaged B
function is not carried out
switch transmission to neutral (N)

496448 E/A-Modul 4: operation supports operation of support control unit with travel direction R engaged B
function is not carried out
switch transmission to neutral (N)

496449 E/A-Modul 4: operation supports op. of upper-carriage monitor with travel direction D engaged B
function is not carried out
switch transmission to neutral (N)

496450 E/A-Modul 4: operation supports operation of upper-carriage-monitor R B


function is not carried out
switch transmission to neutral (N)

496452 E/A-Modul 4: operation supports unauthorised activation of left support control unit key B
left support blocked
release activated key after having authorized function through hand- key

499890 E/A-Modul 4: operation diagnosis system test program not executable as engine is not OFF B
function is not carried out
shut down engine

002389508 193
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

499892 E/A-Modul 4: operation diagnosis system test program not executable as not in under-carriage op. mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode

561001 E/A-Modul 5: system error OS-C167 initialising error processor-register erroneous E 2


error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

561002 E/A-Modul 5: system error OS-C167 initialising error test total in EPROM/FLASH erroneous E 2
error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

561006 E/A-Modul 5: system error OS-C167 initialising error RAM erroneous E 2


error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

561013 E/A-Modul 5: system error OS-C167 test total in EPROM/FLASH erroneous E 2


error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

561016 E/A-Modul 5: system error OS-C167 system-, driver-watchdog expired E 2


error indication on display
note error report, ignition On/Off, with regular occurrence --> notify after-sales service

561068 E/A-Modul 5: system error OS-C167 impermissible interrupt E 2


error indication on display
note error report, ignition On/Off, with regular occurrence --> notify after-sales service

561080 E/A-Modul 5: system error OS-C167 fatal internal software error E 2


error indication on display
note error report, ignition On/Off, with regular occurrence --> notify after-sales service

561082 E/A-Modul 5: system error OS-C167 hardware-watchdog erroneous E 2


error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul

572052 E/A-Modul 5: input/output DEA0 output open, to low load, short circuit to supply voltage X653:17 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

002389508 194
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

572053 E/A-Modul 5: input/output DEA0 transistor current supply insufficient or missing X653:17 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

572054 E/A-Modul 5: input/output DEA0 short circuit to supply voltage X653:17 E 1


error report on display
check output for short, if necessary replace E/A-Modul

572055 E/A-Modul 5: input/output DEA0 excessive temperature, short circuit to ground or overload X653:17 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

572152 E/A-Modul 5: input/output DEA1 output open, to low load, short circuit to supply voltage X653:15 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

572153 E/A-Modul 5: input/output DEA1 transistor current supply insufficient or missing X653:15 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

572154 E/A-Modul 5: input/output DEA1 short circuit to supply voltage X653:15 E 1


error report on display
check output for short, if necessary replace E/A-Modul

572155 E/A-Modul 5: input/output DEA1 excessive temperature, short circuit to ground or overload X653:15 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

572252 E/A-Modul 5: input/output DEA2 output open, to low load, short circuit to supply voltage X653:13 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

572253 E/A-Modul 5: input/output DEA2 transistor current supply insufficient or missing X653:13 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

572254 E/A-Modul 5: input/output DEA2 short circuit to supply voltage X653:13 E 1


error report on display
check output for short, if necessary replace E/A-Modul

002389508 195
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

572255 E/A-Modul 5: input/output DEA2 excessive temperature, short circuit to ground or overload X653:13 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

572352 E/A-Modul 5: input/output DEA3 output open, to low load, short circuit to supply voltage X653:11 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

572353 E/A-Modul 5: input/output DEA3 transistor current supply insufficient or missing X653:11 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

572354 E/A-Modul 5: input/output DEA3 short circuit to supply voltage X653:11 E 1


error report on display
check output for short, if necessary replace E/A-Modul

572355 E/A-Modul 5: input/output DEA3 excessive temperature, short circuit to ground or overload X653:11 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

572452 E/A-Modul 5: input/output DEA4 output open, to low load, short circuit to supply voltage X653:9 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

572453 E/A-Modul 5: input/output DEA4 transistor current supply insufficient or missing X653:9 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

572454 E/A-Modul 5: input/output DEA4 short circuit to supply voltage X653:9 E 1


error report on display
check output for short, if necessary replace E/A-Modul

572455 E/A-Modul 5: input/output DEA4 excessive temperature, short circuit to ground or overload X653:9 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

572552 E/A-Modul 5: input/output DEA5 output open, to low load, short circuit to supply voltage X653:7 U-58.5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

002389508 196
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

572553 E/A-Modul 5: input/output DEA5 transistor current supply insufficient or missing X653:7 U-58.5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

572554 E/A-Modul 5: input/output DEA5 short circuit to supply voltage X653:7 U-58.5 E 1
error report on display
check output for short, if necessary replace E/A-Modul

572555 E/A-Modul 5: input/output DEA5 excessive temperature, short circuit to ground or overload X653:7 U-58.5 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

572652 E/A-Modul 5: input/output DEA6 output open, to low load, short circuit to supply voltage X653:5 U-67.7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

572653 E/A-Modul 5: input/output DEA6 transistor current supply insufficient or missing X653:5 U-67.7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

572654 E/A-Modul 5: input/output DEA6 short circuit to supply voltage X653:5 U-67.7 E 1
error report on display
check output for short, if necessary replace E/A-Modul

572655 E/A-Modul 5: input/output DEA6 excessive temperature, short circuit to ground or overload X653:5 U-67.7 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

572752 E/A-Modul 5: input/output DEA7 output open, to low load, short circuit to supply voltage X653:3 U-67.6 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

572753 E/A-Modul 5: input/output DEA7 transistor current supply insufficient or missing X653:3 U-67.6 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

572754 E/A-Modul 5: input/output DEA7 short circuit to supply voltage X653:3 U-67.6 E 1
error report on display
check output for short, if necessary replace E/A-Modul

002389508 197
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

572755 E/A-Modul 5: input/output DEA7 excessive temperature, short circuit to ground or overload X653:3 U-67.6 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

579052 E/A-Modul 5: output A0 output open, to low load, short circuit to supply voltage X653:18 U-58.2 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

579053 E/A-Modul 5: output A0 transistor current supply insufficient or missing X653:18 U-58.2 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

579054 E/A-Modul 5: output A0 short circuit to supply voltage X653:18 U-58.2 E 1


error report on display
check output for short, if necessary replace E/A-Modul

579055 E/A-Modul 5: output A0 excessive temperature, short circuit to ground or overload X653:18 U-58.2 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

579152 E/A-Modul 5: output A1 output open, to low load, short circuit to supply voltage X653:16 U-58.5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

579153 E/A-Modul 5: output A1 transistor current supply insufficient or missing X653:16 U-58.5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

579154 E/A-Modul 5: output A1 short circuit to supply voltage X653:16 U-58.5 E 1


error report on display
check output for short, if necessary replace E/A-Modul

579155 E/A-Modul 5: output A1 excessive temperature, short circuit to ground or overload X653:16 U-58.5 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

579250 E/A-Modul 5: bridge output A2 short circuit to ground, junction not supplied X653:14 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul

002389508 198
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

579251 E/A-Modul 5: bridge output A2 short circuit to supply voltage, excessive temperature X653:14 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul

579252 E/A-Modul 5: bridge output A2 output open, to low load, short circuit to supply voltage X653:14 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

579253 E/A-Modul 5: bridge output A2 transistor current supply insufficient or missing X653:14 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

579254 E/A-Modul 5: bridge output A2 short circuit to supply voltage X653:14 E 1


error report on display
check output for short, if necessary replace E/A-Modul

579255 E/A-Modul 5: bridge output A2 excessive temperature, short circuit to ground or overload X653:14 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

579350 E/A-Modul 5: bridge output A3 short circuit to ground, junction not supplied X653:12 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul

579351 E/A-Modul 5: bridge output A3 short circuit to supply voltage, excessive temperature X653:12 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul

579352 E/A-Modul 5: bridge output A3 output open, to low load, short circuit to supply voltage X653:12 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul

579353 E/A-Modul 5: bridge output A3 transistor current supply insufficient or missing X653:12 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul

579354 E/A-Modul 5: bridge output A3 short circuit to supply voltage X653:12 E 1


error report on display
check output for short, if necessary replace E/A-Modul

002389508 199
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

579355 E/A-Modul 5: bridge output A3 excessive temperature, short circuit to ground or overload X653:12 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul

584050 E/A-Modul 5: LSB-B participant address 0 reports an incorrect sensor type X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

584051 E/A-Modul 5: LSB-B participant address 0 was not configured for the block transfer X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

584053 E/A-Modul 5: LSB-B participant address 0 no longer reports or withdrawn during running period X653:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

584054 E/A-Modul 5: LSB-B participant address 0 Features other settings (parameters) as pre-entered set values X653:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

584064 E/A-Modul 5: LSB-B participant address 0 reports tolerable error in self-test X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

584065 E/A-Modul 5: LSB-B participant address 0 reports intolerable error in self-test X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

584066 E/A-Modul 5: LSB-B participant address 0 with software version, that is no longer compatible X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

584067 E/A-Modul 5: LSB-B participant address 0 supports no download function X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

584150 E/A-Modul 5: LSB-B participant address 1 reports an incorrect sensor type X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

002389508 200
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

584151 E/A-Modul 5: LSB-B participant address 1 was not configured for the block transfer X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

584153 E/A-Modul 5: LSB-B participant address 1 no longer reports or withdrawn during running period X653:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

584154 E/A-Modul 5: LSB-B participant address 1 Features other settings (parameters) as pre-entered set values X653:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

584164 E/A-Modul 5: LSB-B participant address 1 reports tolerable error in self-test X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

584165 E/A-Modul 5: LSB-B participant address 1 reports intolerable error in self-test X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

584166 E/A-Modul 5: LSB-B participant address 1 with software version, that is no longer compatible X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

584167 E/A-Modul 5: LSB-B participant address 1 supports no download function X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

584250 E/A-Modul 5: LSB-B participant address 2 reports an incorrect sensor type X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

584251 E/A-Modul 5: LSB-B participant address 2 was not configured for the block transfer X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

584253 E/A-Modul 5: LSB-B participant address 2 no longer reports or withdrawn during running period X653:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

002389508 201
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

584254 E/A-Modul 5: LSB-B participant address 2 Features other settings (parameters) as pre-entered set values X653:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

584264 E/A-Modul 5: LSB-B participant address 2 reports tolerable error in self-test X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

584265 E/A-Modul 5: LSB-B participant address 2 reports intolerable error in self-test X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

584266 E/A-Modul 5: LSB-B participant address 2 with software version, that is no longer compatible X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

584267 E/A-Modul 5: LSB-B participant address 2 supports no download function X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

584350 E/A-Modul 5: LSB-B participant address 3 reports an incorrect sensor type X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

584351 E/A-Modul 5: LSB-B participant address 3 was not configured for the block transfer X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

584353 E/A-Modul 5: LSB-B participant address 3 no longer reports or withdrawn during running period X653:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

584354 E/A-Modul 5: LSB-B participant address 3 Features other settings (parameters) as pre-entered set values X653:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

584364 E/A-Modul 5: LSB-B participant address 3 reports tolerable error in self-test X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

002389508 202
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

584365 E/A-Modul 5: LSB-B participant address 3 reports intolerable error in self-test X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

584366 E/A-Modul 5: LSB-B participant address 3 with software version, that is no longer compatible X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

584367 E/A-Modul 5: LSB-B participant address 3 supports no download function X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

584450 E/A-Modul 5: LSB-B participant address 4 reports an incorrect sensor type X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

584451 E/A-Modul 5: LSB-B participant address 4 was not configured for the block transfer X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

584453 E/A-Modul 5: LSB-B participant address 4 no longer reports or withdrawn during running period X653:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

584454 E/A-Modul 5: LSB-B participant address 4 Features other settings (parameters) as pre-entered set values X653:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

584464 E/A-Modul 5: LSB-B participant address 4 reports tolerable error in self-test X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

584465 E/A-Modul 5: LSB-B participant address 4 reports intolerable error in self-test X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

584466 E/A-Modul 5: LSB-B participant address 4 with software version, that is no longer compatible X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

002389508 203
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

584467 E/A-Modul 5: LSB-B participant address 4 supports no download function X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

584550 E/A-Modul 5: LSB-B participant address 5 reports an incorrect sensor type X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

584551 E/A-Modul 5: LSB-B participant address 5 was not configured for the block transfer X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

584553 E/A-Modul 5: LSB-B participant address 5 no longer reports or withdrawn during running period X653:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

584554 E/A-Modul 5: LSB-B participant address 5 Features other settings (parameters) as pre-entered set values X653:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

584564 E/A-Modul 5: LSB-B participant address 5 reports tolerable error in self-test X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

584565 E/A-Modul 5: LSB-B participant address 5 reports intolerable error in self-test X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

584566 E/A-Modul 5: LSB-B participant address 5 with software version, that is no longer compatible X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

584567 E/A-Modul 5: LSB-B participant address 5 supports no download function X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

584650 E/A-Modul 5: LSB-B participant address 6 reports an incorrect sensor type X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor

002389508 204
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

584651 E/A-Modul 5: LSB-B participant address 6 was not configured for the block transfer X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software

584653 E/A-Modul 5: LSB-B participant address 6 no longer reports or withdrawn during running period X653:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor

584654 E/A-Modul 5: LSB-B participant address 6 Features other settings (parameters) as pre-entered set values X653:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value

584664 E/A-Modul 5: LSB-B participant address 6 reports tolerable error in self-test X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor

584665 E/A-Modul 5: LSB-B participant address 6 reports intolerable error in self-test X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately

584666 E/A-Modul 5: LSB-B participant address 6 with software version, that is no longer compatible X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part

584667 E/A-Modul 5: LSB-B participant address 6 supports no download function X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out

587252 E/A-Modul 5: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X653:4/6 U-46.6/46.5 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor

587255 E/A-Modul 5: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X653:4/6 U-46.6/46.5 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

587256 E/A-Modul 5: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X653:4/6 U-46.6/46.5 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

002389508 205
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

587257 E/A-Modul 5: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X653:4/6 U-46.6/46.5 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part

587258 E/A-Modul 5: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X653:4/6 U-46.6/46.5 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors

587259 E/A-Modul 5: Control data transfer LSB-B recognised communication breakdown in bus X653:4/6 U-46.6/46.5 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network

587260 E/A-Modul 5: Control data transfer LSB-B driver error: no order to carry out X653:4/6 U-46.6/46.5 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software

587261 E/A-Modul 5: Control data transfer LSB-B driver error: undefined message appears X653:4/6 U-46.6/46.5 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination

587262 E/A-Modul 5: Control data transfer LSB-B driver error: initialising error X653:4/6 U-46.6/46.5 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination

587530 E/A-Modul 5: CAN-participant engine Data transfer subscriber transfer cycle exceeded X655:5/6 U-51.6/51.7 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

587531 E/A-Modul 5: CAN-participant engine Data transfer faulty/missing, max. cycle time exceeded X655:5/6 U-51.6/51.7 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

587630 E/A-Modul 5: CAN-participant gear Data transfer subscriber transfer cycle exceeded X655:5/6 U-51.6/51.7 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

587631 E/A-Modul 5: CAN-participant gear Data transfer faulty/missing, max. cycle time exceeded X655:5/6 U-51.6/51.7 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

002389508 206
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

587730 E/A-Modul 5: CAN-participant ABV (ABS/ASR) Data transfer subscriber transfer cycle exceeded X655:5/6 U-51.6/51.7 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

587731 E/A-Modul 5: CAN-participant ABV (ABS/ASR) Data transfer faulty/missing, max. cycle time exceeded X655:5/6 U-51.6/51.7 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

588530 E/A-Modul 5: CAN-participant E/A-Modul 1 Data transfer subscriber transfer cycle exceeded X655:5/6 U-51.6/51.7 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

588531 E/A-Modul 5: CAN-participant E/A-Modul 1 Data transfer faulty/missing, max. cycle time exceeded X655:5/6 U-51.6/51.7 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

588930 E/A-Modul 5: CAN-participant E/A-Modul 5 Data transfer subscriber transfer cycle exceeded X655:5/6 U-51.6/51.7 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant

588931 E/A-Modul 5: CAN-participant E/A-Modul 5 Data transfer faulty/missing, max. cycle time exceeded X655:5/6 U-51.6/51.7 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant

589900 E/A-Modul 5: Control data transfer CAN internal error: register error CAN-controller X655:5/6 U-51.6/51.7 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul

589901 E/A-Modul 5: Control data transfer CAN internal error: RAM-error CAN-controller X655:5/6 U-51.6/51.7 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul

589902 E/A-Modul 5: Control data transfer CAN configuration error CAN-software X655:5/6 U-51.6/51.7 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul, check Software (test system ZE)

589903 E/A-Modul 5: Control data transfer CAN Transfer interrupted after continuous error X655:5/6 U-51.6/51.7 E 1
CAN-Transmission will be aborted
check bus lines/neutral point, replace neutral point or E/A-Modul

002389508 207
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

589910 E/A-Modul 5: Control data transfer CAN short-term error in bus connection X655:5/6 U-51.6/51.7 E 0
re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated

589911 E/A-Modul 5: Control data transfer CAN permanent error bus connection X655:5/6 U-51.6/51.7 E 1
cyclic re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated

589920 E/A-Modul 5: Control data transfer CAN active participant not responding X655:5/6 U-51.6/51.7 E 0
parameterised substitute values for receiver signals will be used
check error report for missing participant(s), test system ZE

589921 E/A-Modul 5: Control data transfer CAN No active subscriber responding X655:5/6 U-51.6/51.7 E 1
parameterised substitute values for receiver signals will be used
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul

589950 E/A-Modul 5: Control data transfer CAN erroneous command test system X655:5/6 U-51.6/51.7 E 1
no reaction to unknown test system control command in CAN-System Software
check Software (test system)

592000 E/A-Modul 5: control engine long-term disruption E/A-Modul <-> accelerator crane op. cab E 1
engine in idle speed, after re-generation of the connection first idle speed
check LSB-connection ZE<>E/A-Modul, crane operators cab accelerator or connection to ZE (test system)

592001 E/A-Modul 5: control engine long-term disruption E/A-Modul <-> engine control E 1
engine control and E/A-Modul at emergency speed
engine control and E/A-Modul, check CAN-bus-connections

592005 E/A-Modul 5: control engine condition erroneous: CAN-signal engine ON <-> load ctrl. D+ OFF E 1
identification engine ON/OFF possibly erronous
check alternator line connection to display unit, check alternator signal

592006 E/A-Modul 5: control engine condition erroneous: CAN-signal engine OFF <-> load ctrl. D+ ON E 1
identification engine ON/OFF possibly erronous
check alternator line connection to display unit, check alternator signal

592034 E/A-Modul 5: control engine tacograph speed signal missing E 1


Tempomat/Temposet-function blocked, engine will be limited in the torque output
Tacograph connection <>E/A-Modul, check signals to inputs from E/A-Modul; replace E/A-Modul Taco

002389508 208
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

592035 E/A-Modul 5: control engine tacograph speed signal erroneous E 1


Tempomat/Temposet-function blocked, engine will be limited in the torque output
Tacograph connection <>E/A-Modul, check signals to inputs from E/A-Modul; replace E/A-Modul Taco

592036 E/A-Modul 5: control engine tacograph speed signal <-> gear output implausibel E 1
Tempomat/Temposet-function blocked, engine will be limited in the torque output
Tacograph connection <>E/A-Modul, signals to inputs from E/A-Modul, check gear speed; replace E/A-Modul Taco

592121 E/A-Modul 5: control transmission shift selector-specified gear range/travel direction erroneous E 1
travel switch signals will be switched off, emergency operation
check CAN-bus system, Check Software in E/A-Modules (test system)

592957 E/A-Modul 5: control brakes/pneumatic system brake pressure switch 0.5 bar signal "op. brakes active" missing E 1
operation brake signal activated if circle 1+2 > 1,5 bar, stronger application of the brake necessary
check connection from brake pressure switch to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593160 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 1 missing E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593161 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 2 missing E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593162 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 3 missing E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593165 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 1 short to supply voltage E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593166 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 2 short to supply voltage E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593167 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 3 short to supply voltage E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

002389508 209
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

593175 E/A-Modul 5: instruments operators cab Tempomat lever no signal or supply voltage missing E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593176 E/A-Modul 5: instruments operators cab Tempomat lever signal SET+ no signal or short to ground E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593177 E/A-Modul 5: instruments operators cab Tempomat lever signal SET- no signal or short to ground E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593178 E/A-Modul 5: instruments operators cab Tempomat lever signal OFF no signal or short to ground E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593179 E/A-Modul 5: instruments operators cab Tempomat lever signal QUIT short to supply voltage E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593180 E/A-Modul 5: instruments operators cab Tempomat lever signal TEMPOSET short to supply voltage E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593181 E/A-Modul 5: instruments operators cab Tempomat lever signal TEMPOMAT SET+ without returning (QUIT) E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593182 E/A-Modul 5: instruments operators cab Tempomat lever signal TEMPOMAT SET- without returning (QUIT) E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593183 E/A-Modul 5: instruments operators cab Tempomat lever signal OFF without returning (QUIT) E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

593184 E/A-Modul 5: instruments operators cab Tempomat lever signals SET+, SET-, OFF erroneous combination E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul

002389508 210
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

594190 E/A-Modul 5: LSB-bus participant ZE missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

594191 E/A-Modul 5: LSB-bus participant E/A-Modul 1 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

594192 E/A-Modul 5: LSB-bus participant E/A-Modul 2 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

594193 E/A-Modul 5: LSB-bus participant E/A-Modul 3 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

594194 E/A-Modul 5: LSB-bus participant E/A-Modul 4 missing E 1


communication with participant not possible, after re-starting of bus communication error will be reset
check LSB-network, check participant

595074 E/A-Modul 5: operation engine accelerator operators cab blocked in upper-carriage operation mode B

595075 E/A-Modul 5: operation engine accelerator operators cab blocked in support operation mode B

595076 E/A-Modul 5: operation engine accelerator op. cab blocked when auxiliary brake active or selected B

595077 E/A-Modul 5: operation engine accelerator upper-carr. activated on malf. of GAS <-> E/A-Modul B

596885 E/A-Modul 5: operation instruments operators cab Tempomat lever blocked in upper-carriage operation mode B

002389508 211
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

596886 E/A-Modul 5: operation instruments operators cab Tempomat lever blocked in support operation mode B

687252 E/A-Modul 6: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X663:4/6 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor

687255 E/A-Modul 6: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X663:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

687256 E/A-Modul 6: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X663:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board

687257 E/A-Modul 6: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X663:4/6 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part

687258 E/A-Modul 6: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X663:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors

687259 E/A-Modul 6: Control data transfer LSB-B recognised communication breakdown in bus X663:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network

687260 E/A-Modul 6: Control data transfer LSB-B driver error: no order to carry out X663:4/6 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software

687261 E/A-Modul 6: Control data transfer LSB-B driver error: undefined message appears X663:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination

687262 E/A-Modul 6: Control data transfer LSB-B driver error: initialising error X663:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination

002389508 212
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

810160 ABV: CAN-bus system disrupted data communication X94:1/2/3 U-93.7/93.8/93.6 E 0


ABV function not restricted
check CAN-network, check/replace ABV-control device

810162 ABV: CAN-bus system Speed signal Tachograph to CAN faulty/missing/implausible X94:1/2/3 U-93.7/93.8/93.6 E 1
ABV function not restricted
check CAN-network, ABV-control device, speed signal C3, E/A-Modul 5

810163 ABV: CAN-bus system Interruption/continuous control line(s) X94:1/2/3 U-93.7/93.8/93.6 E 0


ABV function not restricted
check CAN-network, check/replace ABV-control device

810167 ABV: CAN-bus system CAN-communication gears faulty/not present X94:1/2/3 U-93.7/93.8/93.6 E 0
ABV function not restricted
check CAN-network, check/replace ABV-control device

810168 ABV: CAN-bus system CAN-communication engine or E/A-Modul 5 faulty/not present X94:1/2/3 U-93.7/93.8/93.6 E 0
ABV function not restricted
check CAN-network, check/replace ABV-control device

810169 ABV: CAN-bus system CAN-communication E/A-Modul 2 faulty/not present X94:1/2/3 U-93.7/93.8/93.6 E 0
ABV function not restricted
check CAN-network, check/replace ABV-control device

811001 ABV: control device error or power supply Kl.15/30 excess voltage X94:7/9 U-93.3/93.2 E 1
ABS: inactive
check net supply control device

811002 ABV: control device error or power supply Kl.15/30 voltage below required value X94:7/9 U-93.3/93.2 E 1
ABS: inactive
check net supply control device

811010 ABV: control device error or power supply Kl.15/30 defect X94:7/9 U-93.3/93.2 E 1
ABS: inactive, ASR: inactive
replace control device

811012 ABV: control device error or power supply Kl.15/30 incorrect parameters X94:7/9 U-93.3/93.2 E 1
ABS: inactive, ASR: inactive
replace control device

002389508 213
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

811029 ABV: control device error or power supply Kl.15/30 monitor switch time for solenoid valve actuated X94:7/9 U-93.3/93.2 E 0
ABS: inactive, ASR: inactive
check solenoid valve, control device

811094 ABV: control device error or power supply Kl.15/30 Wheel speeds/tyre dimensions implausible, incorrect parameterisation X94:7/9 U-93.3/93.2 E 1
ABS: wheel not regulated, ASR: inactive
check tires, magnet wheels, sensors

811102 ABV: control device error or power supply Kl.15/30 voltage below required value X94:7/9 U-93.3/93.2 E 1
ABS: inactive
check net supply control device

811103 ABV: control device error or power supply Kl.15/30 interruption X94:7/9 U-93.3/93.2 E 1
ABS: inactive
check net supply control device

811202 ABV: control device error or power supply Kl.15/30 voltage below required value X94:7/9 U-93.3/93.2 E 1
ABS: inactive
check net supply control device

811203 ABV: control device error or power supply Kl.15/30 interruption X94:7/9 U-93.3/93.2 E 1
ABS: inactive
check net supply control device

811602 ABV: control device error, power supply Kl.31 voltage below required value X94:10/12 U-93.4/93.5 E 1
ABS: inactive
check net supply control device

811609 ABV: control device error, power supply Kl.31 interruption X94:10/12 U-93.4/93.5 E 1
ABS: inactive
check net supply control device

811702 ABV: control device error, power supply Kl.31 voltage below required value X94:10/12 U-93.4/93.5 E 1
ABS: inactive
check net supply control device

811709 ABV: control device error, power supply Kl.31 interruption X94:10/12 U-93.4/93.5 E 1
ABS: inactive
check net supply control device

002389508 214
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

812004 ABV: output longitudinal lock short circuit to ground E 1

check output, output is not connected!

812005 ABV: output longitudinal lock short circuit to supply voltage E 1

check output, output is not connected!

812103 ABV: output trailer shut-down interruption E 1

check output, output is not connected!

812104 ABV: output trailer shut-down short circuit to ground E 1

check output, output is not connected!

812105 ABV: output trailer shut-down short circuit to supply voltage E 1

check output, output is not connected!

812112 ABV: output trailer shut-down incorrect parameters E 0

check output, output is not connected!, replace control device

813020 ABV: ABS-solenoid valve front axle right interruption X96:7/8/9 U-94.4/94.3/94.3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813021 ABV: ABS-solenoid valve front axle right short circuit to ground X96:7/8/9 U-94.4/94.3/94.3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813022 ABV: ABS-solenoid valve front axle right short circuit to supply voltage X96:7/8/9 U-94.4/94.3/94.3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813023 ABV: ABS-solenoid valve front axle right interruption X96:7/8/9 U-94.4/94.3/94.3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

002389508 215
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

813026 ABV: ABS-solenoid valve front axle right interruption X96:7/8/9 U-94.4/94.3/94.3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813027 ABV: ABS-solenoid valve front axle right short circuit to ground X96:7/8/9 U-94.4/94.3/94.3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813028 ABV: ABS-solenoid valve front axle right short circuit to supply voltage X96:7/8/9 U-94.4/94.3/94.3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813030 ABV: ABS-solenoid valve front axle right external control X96:7/8/9 U-94.4/94.3/94.3 E 2
ABS: front/rear diagonal and differential brakes inactive
check cabling, valve (ohm resistance), control device

813120 ABV: ABS-solenoid valve front axle left interruption X95:1/2/3 U-94.2/94.1/94.1 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813121 ABV: ABS-solenoid valve front axle left short circuit to ground X95:1/2/3 U-94.2/94.1/94.1 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813122 ABV: ABS-solenoid valve front axle left short circuit to supply voltage X95:1/2/3 U-94.2/94.1/94.1 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813123 ABV: ABS-solenoid valve front axle left interruption X95:1/2/3 U-94.2/94.1/94.1 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813126 ABV: ABS-solenoid valve front axle left interruption X95:1/2/3 U-94.2/94.1/94.1 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813127 ABV: ABS-solenoid valve front axle left short circuit to ground X95:1/2/3 U-94.2/94.1/94.1 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

002389508 216
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

813128 ABV: ABS-solenoid valve front axle left short circuit to supply voltage X95:1/2/3 U-94.2/94.1/94.1 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813130 ABV: ABS-solenoid valve front axle left external control X95:1/2/3 U-94.2/94.1/94.1 E 2
ABS: front/rear diagonal and differential brakes inactive
check cabling, valve (ohm resistance), control device

813220 ABV: ABS-solenoid valve rear axle right interruption X97:10/11/12 U-94.7/94.6/94.6 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813221 ABV: ABS-solenoid valve rear axle right short circuit to ground X97:10/11/12 U-94.7/94.6/94.6 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813222 ABV: ABS-solenoid valve rear axle right short circuit to supply voltage X97:10/11/12 U-94.7/94.6/94.6 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813223 ABV: ABS-solenoid valve rear axle right interruption X97:10/11/12 U-94.7/94.6/94.6 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813226 ABV: ABS-solenoid valve rear axle right interruption X97:10/11/12 U-94.7/94.6/94.6 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813227 ABV: ABS-solenoid valve rear axle right short circuit to ground X97:10/11/12 U-94.7/94.6/94.6 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813228 ABV: ABS-solenoid valve rear axle right short circuit to supply voltage X97:10/11/12 U-94.7/94.6/94.6 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813230 ABV: ABS-solenoid valve rear axle right external control X97:10/11/12 U-94.7/94.6/94.6 E 2
ABS: front/rear diagonal and differential brakes inactive
check cabling, valve (ohm resistance), control device

002389508 217
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

813320 ABV: ABS-solenoid valve rear axle left interruption X97:1/2/3 U-94.5/94.4/94.4 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813321 ABV: ABS-solenoid valve rear axle left short circuit to ground X97:1/2/3 U-94.5/94.4/94.4 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813322 ABV: ABS-solenoid valve rear axle left short circuit to supply voltage X97:1/2/3 U-94.5/94.4/94.4 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813323 ABV: ABS-solenoid valve rear axle left interruption X97:1/2/3 U-94.5/94.4/94.4 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813326 ABV: ABS-solenoid valve rear axle left interruption X97:1/2/3 U-94.5/94.4/94.4 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813327 ABV: ABS-solenoid valve rear axle left short circuit to ground X97:1/2/3 U-94.5/94.4/94.4 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813328 ABV: ABS-solenoid valve rear axle left short circuit to supply voltage X97:1/2/3 U-94.5/94.4/94.4 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813330 ABV: ABS-solenoid valve rear axle left external control X97:1/2/3 U-94.5/94.4/94.4 E 2
ABS: front/rear diagonal and differential brakes inactive
check cabling, valve (ohm resistance), control device

813604 ABV: valve front axle right and rear axle left short circuit to ground X96/X97 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813605 ABV: valve front axle right and rear axle left short circuit to supply voltage X96/X97 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

002389508 218
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

813704 ABV: valve front axle left and rear axle right short circuit to ground X96/X98 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813705 ABV: valve front axle left and rear axle right short circuit to supply voltage X96/X98 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device

813804 ABV: ASR, DIF-valve short circuit to ground X97:4/7 U-94.8/94.8 E 1


ASR: inactive
check cabling, valve (ohm resistance), control device

813805 ABV: ASR, DIF-valve short circuit to supply voltage X97:4/7 U-94.8/94.8 E 1
ASR: inactive
check cabling, valve (ohm resistance), control device

813809 ABV: ASR, DIF-valve interruption X97:4/7 U-94.8/94.8 E 1


ASR: inactive
check cabling, valve (ohm resistance), control device

813812 ABV: ASR, DIF-valve incorrect parameters X97:4/7 U-94.8/94.8 E 0


ASR: inactive
replace control device

814040 ABV: speed sensor front axle right interruption X96:4/5 U-93.3/93.4 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814041 ABV: speed sensor front axle right short circuit to ground X96:4/5 U-93.3/93.4 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814042 ABV: speed sensor front axle right short circuit to supply voltage X96:4/5 U-93.3/93.4 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814044 ABV: speed sensor front axle right winding short X96:4/5 U-93.3/93.4 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

002389508 219
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

814045 ABV: speed sensor front axle right magnet wheel defect X96:4/5 U-93.3/93.4 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel

814046 ABV: speed sensor front axle right sensor vibration X96:4/5 U-93.3/93.4 E 0
ABS: partly inactive, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel

814047 ABV: speed sensor front axle right shimmed magnet wheel X96:4/5 U-93.3/93.4 E 0

check magnet wheel for shimmy

814048 ABV: speed sensor front axle right Air gap, clearance sensor<>magnet wheel too large X96:4/5 U-93.3/93.4 E 1
ABS: wheel not regulated, ASR: inactive
check play in wheel bearing, sensor voltage, ohm resistance of cabling; push sensor on magnet wheel

814140 ABV: speed sensor front axle left interruption X95:4/5 U-93.1/93.2 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814141 ABV: speed sensor front axle left short circuit to ground X95:4/5 U-93.1/93.2 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814142 ABV: speed sensor front axle left short circuit to supply voltage X95:4/5 U-93.1/93.2 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814144 ABV: speed sensor front axle left winding short X95:4/5 U-93.1/93.2 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814145 ABV: speed sensor front axle left magnet wheel defect X95:4/5 U-93.1/93.2 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel

814146 ABV: speed sensor front axle left sensor vibration X95:4/5 U-93.1/93.2 E 0
ABS: partly inactive, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel

002389508 220
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

814147 ABV: speed sensor front axle left shimmed magnet wheel X95:4/5 U-93.1/93.2 E 0

check magnet wheel for shimmy

814148 ABV: speed sensor front axle left Air gap, clearance sensor<>magnet wheel too large X95:4/5 U-93.1/93.2 E 1
ABS: wheel not regulated, ASR: inactive
check play in wheel bearing, sensor voltage, ohm resistance of cabling; push sensor on magnet wheel

814240 ABV: speed sensor rear axle right interruption X97:8/9 U-93.7/93.7 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814241 ABV: speed sensor rear axle right short circuit to ground X97:8/9 U-93.7/93.7 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814242 ABV: speed sensor rear axle right short circuit to supply voltage X97:8/9 U-93.7/93.7 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814244 ABV: speed sensor rear axle right winding short X97:8/9 U-93.7/93.7 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814245 ABV: speed sensor rear axle right magnet wheel defect X97:8/9 U-93.7/93.7 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel

814246 ABV: speed sensor rear axle right sensor vibration X97:8/9 U-93.7/93.7 E 0
ABS: partly inactive, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel

814247 ABV: speed sensor rear axle right shimmed magnet wheel X97:8/9 U-93.7/93.7 E 0

check magnet wheel for shimmy

814248 ABV: speed sensor rear axle right Air gap, clearance sensor<>magnet wheel too large X97:8/9 U-93.7/93.7 E 1
ABS: wheel not regulated, ASR: inactive
check play in wheel bearing, sensor voltage, ohm resistance of cabling; push sensor on magnet wheel

002389508 221
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

814340 ABV: speed sensor rear axle left interruption X97:5/6 U-93.5/93.6 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814341 ABV: speed sensor rear axle left short circuit to ground X97:5/6 U-93.5/93.6 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814342 ABV: speed sensor rear axle left short circuit to supply voltage X97:5/6 U-93.5/93.6 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814344 ABV: speed sensor rear axle left winding short X97:5/6 U-93.5/93.6 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling

814345 ABV: speed sensor rear axle left magnet wheel defect X97:5/6 U-93.5/93.6 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel

814346 ABV: speed sensor rear axle left sensor vibration X97:5/6 U-93.5/93.6 E 0
ABS: partly inactive, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel

814347 ABV: speed sensor rear axle left shimmed magnet wheel X97:5/6 U-93.5/93.6 E 0

check magnet wheel for shimmy

814348 ABV: speed sensor rear axle left Air gap, clearance sensor<>magnet wheel too large X97:5/6 U-93.5/93.6 E 1
ABS: wheel not regulated, ASR: inactive
check play in wheel bearing, sensor voltage, ohm resistance of cabling; push sensor on magnet wheel

843300 heating, air cond.: WEBASTO THERMO 90 S steering device error E 1


no reaction
check fuses, check battery terminals, replace control device

843301 heating, air cond.: WEBASTO THERMO 90 S no start E 1


error report and feedback "supplementary heating ON" flashing on display unit (5x short, 1x long)
check fuel level and fuel filter, bleed fuel system, clean burner or replace

002389508 222
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

843302 heating, air cond.: WEBASTO THERMO 90 S repeated glow interruption E 1


error report and feedback " supplementary heating ON" flashing on display unit (5x short, 2x long)
check fuel level and fuel filter, bleed fuel system, clean burner or replace

843303 heating, air cond.: WEBASTO THERMO 90 S lack of voltage/excess voltage E 1


error report and acknowledgement " supplementary heating ON" flashing on display unit (5x short, 3x long)
check battery, check electrical connections

843304 heating, air cond.: WEBASTO THERMO 90 S premature glow identification E 1


error report and feedback " supplementary heating ON" flashing on display unit (5x short, 4x long)
replace flame detector

843305 heating, air cond.: WEBASTO THERMO 90 S glow probe interruption/short circuit E 1
error report and feedback " supplementary heating ON" flashing on display unit (5x short, 5x long)
check cabling for damage, search for break and short, replace flame detector

843306 heating, air cond.: WEBASTO THERMO 90 S temperature probe interruption/short circuit E 1
error report and feedback " supplementary heating ON" flashing on display unit (5x short, 6x long)
check cabling for damage, search for break and short, replace temperature sensor

843307 heating, air cond.: WEBASTO THERMO 90 S metering pump/solenoid valve interruption/short circuit E 1
error report and feedback " supplementary heating ON" flashing on display unit (5x short, 7x long)
check coolant level, bleed coolant circuit, reset temperature limitation, examine cabling

843308 heating, air cond.: WEBASTO THERMO 90 S blower motor interruption/short circuit/erroneous speed E 1
error report and feedback " supplementary heating ON" flashing on display unit (5x short, 8x long)
check cabling for damage, search for break and short, replace combustion air ventilator

843309 heating, air cond.: WEBASTO THERMO 90 S glow pin interruption/short circuit E 1
error report and feedback " supplementary heating ON" flashing on display unit (5x short, 9x long)
check cabling for damage, search for break and short, replace heater plug

843310 heating, air cond.: WEBASTO THERMO 90 S overheating E 1


error report and feedback " supplementary heating ON" flashing on display unit (5x short, 10x long)
re-fill coolant, press temperature limitation button before switching on, replace temperature limitation

843311 heating, air cond.: WEBASTO THERMO 90 S water pump interruption/short circuit E 1
error report and feedback "supplementary heating ON" flashing on display unit (5x short, 11x long)
check cabling for damage, search for break and short, replace water pump

002389508 223
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

843312 heating, air cond.: WEBASTO THERMO 90 S set value sensor interruption/short circuit E 1
error report and acknowledgement " supplementary heating ON" flashing on display unit (5x short, 12x long)
check cabling for damage, search for break and short, replace set value transmitter

920106 engine V6: control device engine Data communication CAN faulty / interrupted X275:1/4/7 U-51.4/51.4/51.5 E 1
emergency operation
check cable/plugs for shorts

920107 engine V6: control device engine Data communication CAN cancelled X275:1/4/7 U-51.4/51.4/51.5 E 1
emergency operation
check cable/plugs for UB- or shorts to ground

920208 engine V6: CAN-participant ABV (ABS/ASR) Data transfer faulty/missing, max. cycle time exceeded X275:1/4/7 U-51.4/51.4/51.5 E 1
limited function
check cable/plugs/ABS-/ASR-electronics

920308 engine V6: CAN-participant gear Data transfer faulty/missing, max. cycle time exceeded X275:1/4/7 U-51.4/51.4/51.5 E 1
limited function
check cable/plugs/gear electronics

920408 engine V6: CAN-participant E/A-Modul Data transfer faulty/missing, max. cycle time exceeded X275:1/4/7 U-51.4/51.4/51.5 E 1
emergency operation
check cable/plugs/E/A-Modul(e)

920508 engine V6: CAN signals gear Data transfer faulty/missing, max. cycle time exceeded X275:1/4/7 U-51.4/51.4/51.5 E 1
limited function
check cable/plugs/gear electronics

920608 engine V6: CAN signals travel switch Data transfer faulty/missing, max. cycle time exceeded X275:1/4/7 U-51.4/51.4/51.5 E 1
limited function
check cable/plugs/E/A-Modul(e)

920709 engine V6: speed sensor 1 gradient damage X273:19/20 U-55.1/55.2 E 1


switch-over to speed 2 or engine-stop with error code 0809
check cable/plugs/sensor, distance to flywheel

920809 engine V6: speed sensor 2 gradient damage X273:18/21 U-55.3/55.4 E 1


switch-over to speed 2 or engine-stop with error code 0709
check cable/plugs/sensor, distance to flywheel

002389508 224
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

920910 engine V6: speed 1/2 inadmissable signal difference/plausability control defective X273:18/19/20/2 U-55.3/55.1/55.2/55. E 1
switch-over to other speed sensor or engine-stop 1 4
check cable/plugs/sensor, distance to flywheel

921002 engine V6: accelerator 1 sensor defect high/short circ. to supply voltage X274:16/17 U-54.3/54.4 E 1
switch-over to accelerator 2,speed limitation, torque limitation or 20-23
check cable/plugs for UB-shorts

921003 engine V6: accelerator 1 sensor defect low/short circuit to ground X274:16/17 U-54.3/54.4 E 1
switch-over to accelerator 2,speed limitation, torque limitation or 20-23
check cable/plugs for breaks or short to ground

921004 engine V6: accelerator 1 level exceeded X274:16/17 U-54.3/54.4 E 1


switch-over to accelerator 2,speed limitation, torque limitation or 20-23
check cable/plugs for UB-shorts, check pedal unit

921005 engine V6: accelerator 1 below minimum level X274:16/17 U-54.3/54.4 E 1


switch-over to accelerator 2,speed limitation, torque limitation or 20-23
check cable/plugs for break or short to ground, check pedal unit

921102 engine V6: accelerator 2 sensor defect high/short circ. to supply voltage X274:14/15 U-54.1/54.2 E 1
switch-over to accelerator 1, speed limitation, torque limitation or emergency operation at error code 16-19
check cable/plugs for UB-shorts

921103 engine V6: accelerator 2 sensor defect low/short circuit to ground X274:14/15 U-54.1/54.2 E 1
switch-over to accelerator 1, speed limitation, torque limitation or emergency operation at error code 16-19
check cable/plugs for breaks or short to ground

921104 engine V6: accelerator 2 level exceeded X274:14/15 U-54.1/54.2 E 1


switch-over to accelerator 1, speed limitation, torque limitation or emergency operation at error code 16-19
check cable/plugs for UB-shorts, check pedal unit

921105 engine V6: accelerator 2 below minimum level X274:14/15 U-54.1/54.2 E 1


switch-over to accelerator 1, speed limitation, torque limitation or emergency operation at error code 16-19
check cable/plugs for break or short to ground, check pedal unit

921201 engine V6: accelerator 1/2 unit defect X274:14/15/16/1 U-54.1/54.2/54.3/54. E 1


gas reduction or gas withdrawal (idle) 7 4
test error code 16-23, check pedal unit

002389508 225
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

921210 engine V6: accelerator 1/2 inadmissable signal difference/plausability control defective X274:14/15/16/1 U-54.1/54.2/54.3/54. E 1
gas withdrawal (idle) 7 4
check pedal unit, check condition of operation brake

921611 engine V6: trigger signal box EDC excess current recognition X271:7/10 U-54.5/54.5 E 1
engine-Stop
check cable/plugs, replace LH-ECU1, check EDC-actuator, if necessary replace injector pump

921701 engine V6: signal box feedback EDC unit defect X271:13/14/15 U-54.8/54.6/54.7 E 1
engine-Stop
check cable/plugs, replace LH-ECU1, check EDC-actuator, if necessary replace injector pump

921812 engine V6: alternator D+ short circuit to ground X273:14 U-52.4 E 1


warning
check cable/plugs for short to ground

921813 engine V6: alternator D+ open signal circuits X273:14 U-52.4 E 1


signal ignored
check cable/plugs for breaks

921814 engine V6: alternator D+ short circuit to supply voltage X273:14 U-52.4 E 1
signal ignored
check cable/plugs for UB-shorts

921916 engine V6: supply KL30 excess voltage X272:1 U-53.2 E 1


generate error report; Reset: automatic after error counter sequence or regulator reset
check main circuit voltage, check battery

921917 engine V6: supply KL30 voltage below required value X272:1 U-53.2 E 1
generate error report; Reset: automatic after error counter sequence or regulator reset
check main circuit voltage, check battery

922012 engine V6: start engine KL50 short circuit to ground X274:13 U-53.1 E 1
generate error report; Reset: automatic after error counter sequence or regulator reset
check cable/plugs for short to ground

922112 engine V6: DA, flame type heater plugs diagnosis short circuit to ground X271:9 U-57.7 E 1
error report
check cable/plugs for short to ground, replace Relaismodul

002389508 226
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

922113 engine V6: DA, flame type heater plugs diagnosis open signal circuits X271:9 U-57.7 E 1
shut off FGK and MVE
check cable/plugs for breaks, replace Relaismodul

922114 engine V6: DA, flame type heater plugs diagnosis short circuit to supply voltage X271:9 U-57.7 E 1
error report
check cable/plugs for UB-shorts, replace Relaismodul

922211 engine V6: Actuator prestroke excess current recognition X271:12/3 E 1


Engine-stop
Check or replace line connection ECU<->EDC-actuator, EDC-actuator, injection pump

922312 engine V6: Control blower short circuit to ground X274:8/9 E 1


Blower turns at full speed following wire break/short-circuit, no blower regulation possible
Line connection ECU<->fan, ECU-output, check fan valve

922315 engine V6: Control blower open electric circuit X274:8/9 E 1


Blower turns at full speed following wire break/short-circuit, no blower regulation possible
Line connection ECU<->fan, ECU-output, check fan valve

922318 engine V6: Control blower excess temperature X274:8/9 E 1


Blower turns at full speed following wire break/short-circuit, no blower regulation possible
Line connection ECU<->fan, ECU-output, check fan valve

922512 engine V6: Speed signal tachograph short circuit to ground X275:9 E 1
Signal is ignored, switch off of functions TMAT/TSET, reduction of maximum moment due to Vset
Check or replace line connection tachograph<->ECU, tachograph, ECU

922513 engine V6: Speed signal tachograph open signal circuits X275:9 E 1
Signal is ignored, switch off of functions TMAT/TSET, reduction of maximum moment due to Vset
Check or replace line connection tachograph<->ECU, tachograph, ECU

922514 engine V6: Speed signal tachograph short circuit to supply voltage X275:9 E 1
Signal is ignored, switch off of functions TMAT/TSET, reduction of maximum moment due to Vset
Check or replace line connection tachograph<->ECU, tachograph, ECU

922602 engine V6: oil pressure sensor sensor defect high/short circ. to supply voltage X273:1/2/3 U-56.1/56.2/56.3 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor

002389508 227
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

922603 engine V6: oil pressure sensor sensor defect low/short circuit to ground X273:1/2/3 U-56.1/56.2/56.3 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor

922702 engine V6: charge air pressure sensor sensor defect high/short circ. to supply voltage X273:4/5/6 U-55.6/55.7/55.8 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor

922703 engine V6: charge air pressure sensor sensor defect low/short circuit to ground X273:4/5/6 U-55.6/55.7/55.8 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor

922802 engine V6: air filter sensor sensor defect high/short circ. to supply voltage X273:7/8/9 U-57.1/57.3/57.2 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor

922803 engine V6: air filter sensor sensor defect low/short circuit to ground X273:7/8/9 U-57.1/57.3/57.2 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor

923102 engine V6: charge air temperature sensor sensor defect high/short circ. to supply voltage X273:12/15 U-55.4/55.5 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor

923103 engine V6: charge air temperature sensor sensor defect low/short circuit to ground X273:12/15 U-55.4/55.5 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor

923202 engine V6: coolant temperature sensor sensor defect high/short circ. to supply voltage X273:10/11 U-56.7/56.8 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor

923203 engine V6: coolant temperature sensor sensor defect low/short circuit to ground X273:10/11 U-56.7/56.8 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor

923313 engine V6: coolant level sensor open signal circuits X274:10/11 U-56.6/56.6 E 1
signal ignored, substitute value used
check cable/plugs for defects or breaks, replace sensor

002389508 228
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

923402 engine V6: oil temperature sensor sensor defect high/short circ. to supply voltage X273:16/17 U-56.4/56.4 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor

923403 engine V6: oil temperature sensor sensor defect low/short circuit to ground X273:16/17 U-56.4/56.4 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor

923512 engine V6: Sensor jib-movement-detector (NBF) short circuit to ground X271:1/2 E 1
Change-over to power-regulated operation
Check line connection ECU<->NBF sensor, NBV sensor; Replace NBF sensor

923513 engine V6: Sensor jib-movement-detector (NBF) open signal circuits X271:1/2 E 1
Change-over to power-regulated operation
Check line connection ECU<->NBF sensor, NBV sensor; Replace NBF sensor

923514 engine V6: Sensor jib-movement-detector (NBF) short circuit to supply voltage X271:1/2 E 1
Change-over to power-regulated operation
Check line connection ECU<->NBF sensor, NBV sensor; Replace NBF sensor

923601 engine V6: trigger flame type heater plug(s) FGK unit defect X271:4 U-57.5 E 1
shut off FGK and MVE
check cable/plugs for defects or breaks, check FGK, replace Relaismodul

923614 engine V6: trigger flame type heater plug(s) FGK short circuit to supply voltage X271:4 U-57.5 E 1

923615 engine V6: trigger flame type heater plug(s) FGK open electric circuit X271:4 U-57.5 E 1
error report
check cable/plugs for breaks, replace Relaismodul

923618 engine V6: trigger flame type heater plug(s) FGK excess temperature X271:4 U-57.5 E 1
shut off FGK and MVE
check cable/plugs for short to ground, replace Relaismodul

923714 engine V6: solenoid valve additional flow for starting short circuit to supply voltage X271:6 U-57.6 E 1

002389508 229
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

923715 engine V6: solenoid valve additional flow for starting open electric circuit X271:6 U-57.6 E 1
FSA data defective, FGK activation removed, MVE reset: automatic after error counter sequence, after regulator reset

923718 engine V6: solenoid valve additional flow for starting excess temperature X271:6 U-57.6 E 1
shut off FGK and MVE
check cable/plugs for short to ground, replace Relaismodul

923814 engine V6: engine start 50A short circuit to supply voltage X271:5 U-57.4 E 1

923815 engine V6: engine start 50A open electric circuit X271:5 U-57.4 E 1
starting procedure interrupted, shut down FGK and MVE
check cable/plugs for breaks, replace Relaismodul

923818 engine V6: engine start 50A excess temperature X271:5 U-57.4 E 1
starting procedure interrupted, shut down FGK and MVE
check cable/plugs for short to ground, replace Relaismodul

924118 engine V6: control device ECU excess temperature X271 E 1


error report
allow machine to cool, check installation location, if necessary take further cooling measures

924119 engine V6: control device ECU deviation X271 E 1


engine-Stop
regulator-reset (Kl.15), Check cable/plugs EDC-actuator, EDC-actuator; ECU, replace injector pump

924120 engine V6: control device ECU saving error X271 E 1

924221 engine V6: RAM/FLASH memory invalid data record X271 E 1


engine-Stop
insert new EEPROM with appropriate data record and carry out paging or replace LH-ECU1, regulator-reset (Kl.15)

924320 engine V6: EEPROM memory saving error X271 E 1


use of redundant memory (Flash-EPROM)
insert new EEPROM and carry out paging or replace LH-ECU1, regulator-reset (Kl.15)

002389508 230
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

924321 engine V6: EEPROM memory invalid data record X271 E 1


engine start not possible
insert correct EEPROM with appropriate data record or replace LH-ECU1, regulator-reset (Kl.15)

924504 engine V6: Calculation spray begin (SB) level exceeded X271 E 1
Change-over to controlled injection-start operation (SB)

924505 engine V6: Calculation spray begin (SB) below minimum level X271 E 1
Change-over to controlled injection-start operation (SB)

924526 engine V6: Calculation spray begin (SB) No synchronisation possible X271 E 1
Change-over to controlled injection-start operation (SB)
Checking of OT signal transmitter and NBF

926124 engine V6: charge air temperature pre-warning disruption limit 1 X273:12/15 U-55.4/55.5 E 1
warning, engine-protection-info, output reduction
reduce output, check air suction routing and engine

926125 engine V6: charge air temperature pre-warning disruption limit 2 X273:12/15 U-55.4/55.5 E 1
warning, engine-protection-info, output reduction
reduce output, if necessary shut off engine, check air suction routing and engine

926224 engine V6: coolant temperature pre-warning disruption limit 1 X273:10/11 U-56.7/56.8 E 1
warning, engine-protection-info, output reduction
reduce output, check coolant level and engine

926225 engine V6: coolant temperature pre-warning disruption limit 2 X273:10/11 U-56.7/56.8 E 1
warning, engine-protection-info, output reduction
reduce output, if necessary shut off engine, check coolant level and engine

926324 engine V6: coolant level pre-warning disruption limit 1 X274:11/12 U-56.6/55.6 E 1
warning
shut off engine, check coolant level and if necessary replenish, check for leaks

926424 engine V6: oil pressure pre-warning disruption limit 1 X273:1/2/3 U-56.1/56.2/56.3 E 1
warning
shut off engine, check oil level and if necessary replenish, check for leaks

002389508 231
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

926522 engine V6: air filter pressure pre-warning disruption limit 1 X273:7/8/9 U-57.1/57.3/57.2 E 1
pre-warning
replace air filter at next opportunity

926525 engine V6: air filter pressure pre-warning disruption limit 2 X273:7/8/9 U-57.1/57.3/57.2 E 1
warning
replace air filter immediately

926624 engine V6: v-belt break pre-warning disruption limit 1 X273:14 U-52.4 E 1
warning
replace V-belts, check generator and replace if necessary

926724 engine V6: speed pre-warning disruption limit 1 X273:18/19/20/2 U-55.3/55.1/55.2/55. E 1


warning, engine-protection-info, injector quantities 0, activation of engine brake 1 4
shut off engine, regulator-reset (Kl.15)

926824 engine V6: charge air pressure pre-warning disruption limit 1 X273:4/5/6 U-55.6/55.7/55.8 E 1
signal ignored, substitute value will be used, error report
check air suction routing

926825 engine V6: charge air pressure pre-warning disruption limit 2 X273:4/5/6 U-55.6/55.7/55.8 E 1
signal ignored, substitute value will be used, error report
check air suction routing

926924 engine V6: oil temperature pre-warning disruption limit 1 X273:16/17 U-56.4/56.4 E 1
signal ignored, substitute value will be used, error report
check oil level/oil circulation

926925 engine V6: oil temperature pre-warning disruption limit 2 X273:16/17 U-56.4/56.4 E 1
signal ignored, substitute value will be used, error report
check oil level/oil circulation

928150 engine V6: v-belt-control service report interval 1 attained/exceeded X27 E 1


report
check and return

928250 engine V6: change engine oil filter service report interval 1 attained/exceeded X27 E 1
report
check and return

002389508 232
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

928350 engine V6: change engine oil service report interval 1 attained/exceeded X27 E 1
report
change oil and return

928351 engine V6: change engine oil service report interval 2 attained/exceeded X27 E 1
report
change oil and return

928352 engine V6: change engine oil service report interval 3 attained/exceeded X27 E 1
report
change oil and return

928353 engine V6: change engine oil service report interval 4 attained/exceeded X27 E 1
report
change oil and return

928354 engine V6: change engine oil service report interval 5 attained/exceeded X27 E 1
report
change oil and return

928355 engine V6: change engine oil service report interval 6 attained/exceeded X27 E 1
report
change oil and return

928356 engine V6: change engine oil service report interval 7 attained/exceeded X27 E 1
report
change oil and return

928357 engine V6: change engine oil service report interval 8 attained/exceeded X27 E 1
report
change oil and return

928358 engine V6: change engine oil service report interval 9 attained/exceeded X27 E 1
report
change oil and return

928359 engine V6: change engine oil service report interval 10 attained/exceeded X27 E 1
report
change oil and return

002389508 233
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

928650 engine V6: check battery service report interval 1 attained/exceeded X27 E 1
report
check and return

928750 engine V6: change water filter service report interval 1 attained/exceeded X27 E 1
report
change filter and return

928850 engine V6: check antifreeze service report interval 1 attained/exceeded X27 E 1
report
check and return

928950 engine V6: fuel filter level 1 service report interval 1 attained/exceeded X27 E 1
report
change filter and return

929050 engine V6: fuel filter level 2 service report interval 1 attained/exceeded X27 E 1
report
change filter and return

929150 engine V6: valve clearance service report interval 1 attained/exceeded X27 E 1
report
check and return

929250 engine V6: fuel injection valves service report interval 1 attained/exceeded X27 E 1
report
check and return

929350 engine V6: coolant service report interval 1 attained/exceeded X27 E 1


report
check and return

960000 gear 6 WG 260: TCU internal error X45 E 1

transmission, check TCU for other errors

960111 gear 6 WG 260: TCU output AIP1 gear clutch K1 excess current recognition X45:56/12/13 U-65.1/65.6/65.7 E 1

002389508 234
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

960112 gear 6 WG 260: TCU output AIP1 gear clutch K1 short circuit to ground X45:56/12/13 U-65.1/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears

960114 gear 6 WG 260: TCU output AIP1 gear clutch K1 short circuit to supply voltage X45:56/12/13 U-65.1/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears

960115 gear 6 WG 260: TCU output AIP1 gear clutch K1 open electric circuit X45:56/12/13 U-65.1/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears

960211 gear 6 WG 260: TCU output AIP2 gear clutch K2 excess current recognition X45:10/12/13 U-65.2/65.6/65.7 E 1

960212 gear 6 WG 260: TCU output AIP2 gear clutch K2 short circuit to ground X45:10/12/13 U-65.2/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears

960214 gear 6 WG 260: TCU output AIP2 gear clutch K2 short circuit to supply voltage X45:10/12/13 U-65.2/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears

960215 gear 6 WG 260: TCU output AIP2 gear clutch K2 open electric circuit X45:10/12/13 U-65.2/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears

960311 gear 6 WG 260: TCU output AIP3 gear clutch K3 excess current recognition X45:32/12/13 U-65.3/65.6/65.7 E 1

960312 gear 6 WG 260: TCU output AIP3 gear clutch K3 short circuit to ground X45:32/12/13 U-65.3/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears

960314 gear 6 WG 260: TCU output AIP3 gear clutch K3 short circuit to supply voltage X45:32/12/13 U-65.3/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears

002389508 235
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

960315 gear 6 WG 260: TCU output AIP3 gear clutch K3 open electric circuit X45:32/12/13 U-65.3/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears

960411 gear 6 WG 260: TCU output AIP4 gear clutch K4 excess current recognition X45:55/12/13 U-65.4/65.6/65.7 E 1

960412 gear 6 WG 260: TCU output AIP4 gear clutch K4 short circuit to ground X45:55/12/13 U-65.4/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears

960414 gear 6 WG 260: TCU output AIP4 gear clutch K4 short circuit to supply voltage X45:55/12/13 U-65.4/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears

960415 gear 6 WG 260: TCU output AIP4 gear clutch K4 open electric circuit X45:55/12/13 U-65.4/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears

960511 gear 6 WG 260: TCU output AIP5 gear clutch KV excess current recognition X45:9/12/13 U-65.4/65.6/65.7 E 1

960512 gear 6 WG 260: TCU output AIP5 gear clutch KV short circuit to ground X45:9/12/13 U-65.4/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears

960514 gear 6 WG 260: TCU output AIP5 gear clutch KV short circuit to supply voltage X45:9/12/13 U-65.4/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears

960515 gear 6 WG 260: TCU output AIP5 gear clutch KV open electric circuit X45:9/12/13 U-65.4/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears

960611 gear 6 WG 260: TCU output AIP6 gear clutch KR excess current recognition X45:51/12/13 U-65.5/65.6/65.7 E 1

002389508 236
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

960612 gear 6 WG 260: TCU output AIP6 gear clutch KR short circuit to ground X45:51/12/13 U-65.5/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears

960614 gear 6 WG 260: TCU output AIP6 gear clutch KR short circuit to supply voltage X45:51/12/13 U-65.5/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears

960615 gear 6 WG 260: TCU output AIP6 gear clutch KR open electric circuit X45:51/12/13 U-65.5/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears

961142 gear 6 WG 260: clutch K1 slip X45 E 1


TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
pressure K1, main pressure system, check sensor distance/signal speed sensors; replace coupling

961242 gear 6 WG 260: clutch K2 slip X45 E 1


TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
pressure K2, main pressure system, check sensor distance/signal speed sensors; replace coupling

961342 gear 6 WG 260: clutch K3 slip X45 E 1


TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
pressure K3, main pressure system, check sensor distance/signal speed sensors; replace coupling

961442 gear 6 WG 260: clutch K4 slip X45 E 1


TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
pressure K4, main pressure system, check sensor distance/signal speed sensors; replace coupling

961542 gear 6 WG 260: clutch KV slip X45 E 1


TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
pressure KV, main pressure system, check sensor distance/signal speed sensors; replace coupling

961642 gear 6 WG 260: clutch KR slip X45 E 1


TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
pressure KR, main pressure system, check sensor distance/signal speed sensors; replace coupling

961742 gear 6 WG 260: transformer shunting clutch slip X45 E 1


error report
check WK pressure, main pressure system, sensor distance/signal of speed sensors; replace coupling

002389508 237
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

962711 gear 6 WG 260: TCU ADM7 transformer shunting clutch excess current recognition X45:34/8/53 U-64.6/64.7/64.8 E 1

962712 gear 6 WG 260: TCU ADM7 transformer shunting clutch short circuit to ground X45:34/8/53 U-64.6/64.7/64.8 E 1
no reaction; operation mode: normal
check cable TCU<>WK-magnet, connector plug WK-magnet<>TCU, resistance of WK-magnet

962714 gear 6 WG 260: TCU ADM7 transformer shunting clutch short circuit to supply voltage X45:34/8/53 U-64.6/64.7/64.8 E 1
no reaction; operation mode: normal
check cable TCU<>WK-magnet, connector plug WK-magnet<>TCU, resistance of WK-magnet

962715 gear 6 WG 260: TCU ADM7 transformer shunting clutch open electric circuit X45:34/8/53 U-64.6/64.7/64.8 E 1
transformer coupling constantly opened, retarder not available; operation mode: normal
check cable TCU<>WK-magnet, connector plug WK-magnet<>TCU, resistance of WK-magnet

963118 gear 6 WG 260: TCU input ER1 temperature sensor excess temperature X45:46/39 U-65.4/65.4 E 1

963157 gear 6 WG 260: TCU input ER1 temperature sensor open circuit or short circuit to supply voltage X45:46/39 U-65.4/65.4 E 1
no reaction, TCC uses substitute temperature; operation mode: normal
check cable from TCU<->sensor, check connector plug, check temperature sensor

963158 gear 6 WG 260: TCU input ER1 temperature sensor short circuit to ground X45:46/39 U-65.4/65.4 E 1
no reaction, TCC uses substitute temperature; operation mode: normal
check cable from TCU<->sensor, check connector plug, check temperature sensor

963218 gear 6 WG 260: TCU entry ER2 temperature sensor to converter excess temperature X45:49/46 E 1

963257 gear 6 WG 260: TCU entry ER2 temperature sensor to converter open circuit or short circuit to supply voltage X45:49/46 E 1
no reaction, TCC uses substitute temperature; operation mode: normal
check cable from TCU<->sensor, check connector plug, check temperature sensor

963258 gear 6 WG 260: TCU entry ER2 temperature sensor to converter short circuit to ground X45:49/46 E 1
no reaction, TCC uses substitute temperature; operation mode: normal
check cable from TCU<->sensor, check connector plug, check temperature sensor

002389508 238
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

963580 gear 6 WG 260: oil filter contamination sensor report filter exchange X45:17 E 1
possible transmission lubrication malfunction
check oil filter, oil circulation, check sensor

963812 gear 6 WG 260: TCU speed sensor supply VMG1 short circuit to ground X45:3 U-64.3 E 1

963814 gear 6 WG 260: TCU speed sensor supply VMG1 short circuit to supply voltage X45:3 U-64.3 E 1

963912 gear 6 WG 260: TCU speed sensor supply VMG2 short circuit to ground X45:4 U-64.5 E 1

963914 gear 6 WG 260: TCU speed sensor supply VMG2 short circuit to supply voltage X45:4 U-64.5 E 1

964012 gear 6 WG 260: TCU supply 30 VPE1 short circuit to ground X45:23 U-64.3 E 1

964112 gear 6 WG 260: TCU supply 30 VPE2 short circuit to ground X45:68 U-64.4 E 1

964212 gear 6 WG 260: TCU supply 15 VpI short circuit to ground X45:45 U-64.4 E 1

964312 gear 6 WG 260: TCU analogue sensor supply AU1/VMGA2 short circuit to ground X4546 E 1
no reaction, TCU uses substitute temperature; operation mode: normal
check cable/connector plug to sensors, which will be supplied from AU1, check power supply AU1 (about 5V)

964314 gear 6 WG 260: TCU analogue sensor supply AU1/VMGA2 short circuit to supply voltage X4546 E 1
no reaction, TCU uses substitute temperature; operation mode: normal
check cable/connector plug to sensors, which will be supplied from AU1, check power supply AU1 (about 5V)

002389508 239
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

964432 gear 6 WG 260: TCU valve coupling supply VPS1 error X45:12/13 U-65.6/65.7 E 1
switches to "N"; operation mode: TCU-shut-down
check cable from transmission to TCU, check connector plug from gears to TCU, replace TCU

964532 gear 6 WG 260: TCU valve coupling supply VPS2 error X45:8/53 U-64.7/64.8 E 1
switches to "N"; operation mode: TCU-shut-down
check cable from transmission to TCU, check connector plug from gears to TCU, replace TCU

964856 gear 6 WG 260: emergency drive switch supply open circuit or short circuit to ground X45:45 U-64.4 E 1
no emergency program with emergency drive switch possible

965412 gear 6 WG 260: TCU input 4 ED4 emergency drive switch D short circuit to ground X45:43 U-64.7 E 1
no emergency program with emergency drive switch possible

965413 gear 6 WG 260: TCU input 4 ED4 emergency drive switch D open signal circuits X45:43 U-64.7 E 1
no emergency program with emergency drive switch possible

965414 gear 6 WG 260: TCU input 4 ED4 emergency drive switch D short circuit to supply voltage X45:43 U-64.7 E 1
no emergency program with emergency drive switch possible

965512 gear 6 WG 260: TCU input 5 ED5 emergency drive switch R short circuit to ground X45:64 U-64.8 E 1
no emergency program with emergency drive switch possible

965513 gear 6 WG 260: TCU input 5 ED5 emergency drive switch R open signal circuits X45:64 U-64.8 E 1
no emergency program with emergency drive switch possible

965514 gear 6 WG 260: TCU input 5 ED5 emergency drive switch R short circuit to supply voltage X45:64 U-64.8 E 1
no emergency program with emergency drive switch possible

965612 gear 6 WG 260: TCU input 6 ED6 emergency drive switch N short circuit to ground X45:67 U-64.6 E 1
no emergency program with emergency drive switch possible

002389508 240
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

965613 gear 6 WG 260: TCU input 6 ED6 emergency drive switch N open signal circuits X45:67 U-64.6 E 1
no emergency program with emergency drive switch possible

965614 gear 6 WG 260: TCU input 6 ED6 emergency drive switch N short circuit to supply voltage X45:67 U-64.6 E 1
no emergency program with emergency drive switch possible

966712 gear 6 WG 260: TCU RS232 diagnosis SDDK short circuit to ground X45:15 U-65.7 E 1
diagnosis via test device not possible

966713 gear 6 WG 260: TCU RS232 diagnosis SDDK open signal circuits X45:15 U-65.7 E 1
diagnosis via test device not possible

966714 gear 6 WG 260: TCU RS232 diagnosis SDDK short circuit to supply voltage X45:15 U-65.7 E 1
diagnosis via test device not possible

966812 gear 6 WG 260: TCU RS232 diagnosis EUPR short circuit to ground X45:18 U-65.8 E 1
diagnosis via test device not possible

966813 gear 6 WG 260: TCU RS232 diagnosis EUPR open signal circuits X45:18 U-65.8 E 1
diagnosis via test device not possible

966814 gear 6 WG 260: TCU RS232 diagnosis EUPR short circuit to supply voltage X45:18 U-65.8 E 1
diagnosis via test device not possible

967008 gear 6 WG 260: CAN-communication transmission bus transmission exceeded X45:25/26 U-51.1/51.2 E 1

967106 gear 6 WG 260: CAN-communication LH motor permanent error bus connection X45:25/26 U-51.1/51.2 E 1

002389508 241
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

967107 gear 6 WG 260: CAN-communication LH motor maximum participant-transmission cycle exceeded X45:25/26 U-51.1/51.2 E 1
operation mode: control of emergency coupling
check engine control device, check line from CAN-bus, check cable to engine control device

967306 gear 6 WG 260: CAN-communication ABS/ASR permanent error bus connection X45:25/26 U-51.1/51.2 E 1

967307 gear 6 WG 260: CAN-communication ABS/ASR maximum participant-transmission cycle exceeded X45:25/26 U-51.1/51.2 E 1

967406 gear 6 WG 260: CAN-communication E/A-Modul 1 permanent error bus connection X45:25/26 U-51.1/51.2 E 1

967407 gear 6 WG 260: CAN-communication E/A-Modul 1 maximum participant-transmission cycle exceeded X45:25/26 U-51.1/51.2 E 1
TCU switches to "N" and uses emergency transmission switch; operation mode: normal
check E/A Modul, check lines from CAN-bus, check cable to E/A control device

967806 gear 6 WG 260: CAN-communication E/A-Modul 5 permanent error bus connection X45:25/26 U-51.1/51.2 E 1

967807 gear 6 WG 260: CAN-communication E/A-Modul 5 maximum participant-transmission cycle exceeded X45:25/26 U-51.1/51.2 E 1
TCU functions as an engine brake and exhaust flap brake is off; operation mode: normal
check engine control device, check line from CAN-bus, check cable to engine control device

967930 gear 6 WG 260: CAN-signal condition of auxiliary brakes defective/missing X45:25/26 U-51.1/51.2 E 1
no reaction; operation mode normal
check E/A Modul, check lines from CAN-bus, check cable to E/A control device

968030 gear 6 WG 260: CAN-signal retarder requirement defective/missing X45:25/26 U-51.1/51.2 E 1


no reaction; operation mode normal
check E/A Modul, check lines from CAN-bus, check cable to E/A control device

968130 gear 6 WG 260: CAN-signal of secondary output torque defective/missing X45:25/26 U-51.1/51.2 E 1
no reaction, TCU uses emergency secondary drive torque signal; operation mode normal
check E/A Modul, check lines from CAN-bus, check cable to E/A control device

002389508 242
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

968230 gear 6 WG 260: CAN-signal travel mode defective/missing X45:25/26 U-51.1/51.2 E 1


no reaction, TCU uses emergency secondary drive; operation mode normal
check E/A Modul, check lines from CAN-bus, check cable to E/A control device

968330 gear 6 WG 260: CAN-signal starting gear defective/missing X45:25/26 U-51.1/51.2 E 1


no reaction, TCU falls back to emergency start-up gear
check E/A Modul, check lines from CAN-bus, check cable to E/A control device

968430 gear 6 WG 260: CAN-signal of engine output torque defective/missing X45:25/26 U-51.1/51.2 E 1
operation mode: control of emergency coupling
check E/A Modul, check lines from CAN-bus, check cable to E/A control device

968530 gear 6 WG 260: CAN-signal kickdown accelerator op. cab defective/missing X45:25/26 U-51.1/51.2 E 1
no reaction
check E/A Modul, check lines from CAN-bus, check cable to E/A control device

968630 gear 6 WG 260: CAN-signal engine brake exhaust flap defective/missing X45:25/26 U-51.1/51.2 E 1
TCU functions as an exhaust flap brake; operation mode: normal
check E/A Modul, check lines from CAN-bus, check cable to E/A control device

968730 gear 6 WG 260: CAN-signal engine brake 2 defective/missing X45:25/26 U-51.1/51.2 E 1


TCU functions as an engine brake; operation mode: normal
check E/A Modul, check lines from CAN-bus, check cable to E/A control device

968830 gear 6 WG 260: CAN-signal shift selector E/A-Modul defective/missing X45:25/26 U-51.1/51.2 E 1
emergency program with emergency drive switch

968930 gear 6 WG 260: CAN-signal off-road gear defective/missing X45:25/26 U-51.1/51.2 E 1


no reaction, TCU uses emergency secondary drive torque signal; operation mode normal
check E/A Modul, check lines from CAN-bus, check cable to E/A control device

969114 gear 6 WG 260: TCU frequency input 1 EF1 input speed short circuit to supply voltage X45:19/3 U-64.1/64.3 E 1
operation mode: control of emergency coupling
check cable TCU<->sensor, connector plug, positioning sensor, adjustment of positioning sensor

969133 gear 6 WG 260: TCU frequency input 1 EF1 input speed logic error X45:19/3 U-64.1/64.3 E 1
operation mode: control of emergency coupling
check cable TCU<->sensor, check connector plug, check speed sensor, check sensor distance

002389508 243
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

969141 gear 6 WG 260: TCU frequency input 1 EF1 input speed excessive speed X45:19/3 U-64.1/64.3 E 1
compulsory up-shifting disengaged
check engine (pick out recorded error from error memory), check speed sensor

969156 gear 6 WG 260: TCU frequency input 1 EF1 input speed open circuit or short circuit to ground X45:19/3 U-64.1/64.3 E 1
operation mode: control of emergency coupling
check cable TCU<->sensor, check connector plug, check speed sensor

969214 gear 6 WG 260: TCU frequency input 2 EF2 turbine speed short circuit to supply voltage X45:41/3 U-64.2/64.3 E 1
op.mode: control of emergency coupling, on output speed malf., TCU switches to "N", emergency travel func
check cable TCU<->sensor, check connector plug, check speed sensor

969233 gear 6 WG 260: TCU frequency input 2 EF2 turbine speed logic error X45:41/3 U-64.2/64.3 E 1
op.mode: control of emergency coupling, on output speed malf., TCU switches to "N", emergency travel func
check cable TCU<->sensor, check connector plug, check speed sensor

969256 gear 6 WG 260: TCU frequency input 2 EF2 turbine speed open circuit or short circuit to ground X45:41/3 U-64.2/64.3 E 1
op.mode: control of emergency coupling, on output speed malf., TCU switches to "N", emergency travel func
check cable TCU<->sensor, check connector plug, check speed sensor

969314 gear 6 WG 260: TCU frequency input 3 EF3 medium speed short circuit to supply voltage X45:42/3 U-64.3/64.3 E 1
operation mode: control of emergency coupling
check cable TCU<->sensor, check connector plug, check speed sensor

969333 gear 6 WG 260: TCU frequency input 3 EF3 medium speed logic error X45:42/3 U-64.3/64.3 E 1
operation mode: control of emergency coupling
check cable TCU<->sensor, check connector plug, check speed sensor

969356 gear 6 WG 260: TCU frequency input 3 EF3 medium speed open circuit or short circuit to ground X45:42/3 U-64.3/64.3 E 1
operation mode: control of emergency coupling
check cable TCU<->sensor, check connector plug, check speed sensor

969414 gear 6 WG 260: TCU frequency input 4 EF4 output speed short circuit to supply voltage X45:62/4 U-64.4/64.5 E 1
op.mode: control of emergency coupling, on turbine speed malf. TCU switches to "N", emergency drive program
check cable TCU<->sensor, check connector plug, check speed sensor

969433 gear 6 WG 260: TCU frequency input 4 EF4 output speed logic error X45:62/4 U-64.4/64.5 E 1
op.mode: control of emergency coupling, on turbine speed malf. TCU switches to "N", emergency drive program
check cable TCU<->sensor, check connector plug, check speed sensor

002389508 244
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

969456 gear 6 WG 260: TCU frequency input 4 EF4 output speed open circuit or short circuit to ground X45:62/4 U-64.4/64.5 E 1
op.mode: control of emergency coupling, on turbine speed malf. TCU switches to "N", emergency drive program
check cable TCU<->sensor, check connector plug, check speed sensor

969471 gear 6 WG 260: TCU frequency input 4 EF4 output speed speed signal implausible to other speeds X45:62/4 U-64.4/64.5 E 1
op.mode: control of emergency coupling, on turbine speed malf. TCU switches to "N", emergency drive program
check sensor signal of output speed-sensor, check cable from TCU<>sensor

969521 gear 6 WG 260: AEB data record invalid/implausible X45 E 1


switch quality from gears unsatisfactory
AEB-function over test programs in the vehicle or diagnosis device can be carried out error free

969531 gear 6 WG 260: AEB error on execution/function interrupted X45 E 1


switch quality from gears unsatisfactory
AEB-function over test programs in the vehicle or diagnosis device can be carried out error free

969616 gear 6 WG 260: TCU internal excess voltage X45 E 1


switches to "N"; operation mode: TCU-shut-down
check battery and alternator, check cable/connection terminals from battery to TCU

969617 gear 6 WG 260: TCU internal voltage below required value X45 E 1
switches to "N"; operation mode: TCU-shut-down
check battery and alternator, check cable/connection terminals from battery to TCU

969621 gear 6 WG 260: TCU internal data record invalid/implausible X45 E 1

969634 gear 6 WG 260: TCU internal memory error RAM X45 E 1

969635 gear 6 WG 260: TCU internal memory error EEPROM X45 E 1


transmission remains in "N"; operation mode: TCU-shut-down
replace TCU

969636 gear 6 WG 260: TCU internal memory error EPROM or FLASH X45 E 1

002389508 245
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W

969637 gear 6 WG 260: TCU internal watchdog (program monitoring) X45 E 1

969639 gear 6 WG 260: TCU internal application error X45 E 1


transmission remains in "N"; operation mode: TCU-shut-down
replace TCU

969651 gear 6 WG 260: TCU internal short circuit to supply voltage X45 E 1

969760 gear 6 WG 260: TCU logic error gear area signal X45 E 1

969761 gear 6 WG 260: TCU logic error directional selection signal X45 E 1
TCU switches transmission to "N"; operation mode: transmission shut-down

969943 gear 6 WG 260: requirement emergency program X45 E 1

002389508 246