Professional Documents
Culture Documents
Lec 002389508 Eng
Lec 002389508 Eng
LTM 1080/1
002389508
29.10.2003
000001 ZE 0: system error OS-HC11 (observe parameters) initialising error processor-register erroneous E 2
no crane operation possible
with regular occurrence --> replace ZE
000002 ZE 0: system error OS-HC11 (observe parameters) initialising error test total in EPROM/FLASH erroneous E 2
no crane operation possible
check program memory card or ZE
000006 ZE 0: system error OS-HC11 (observe parameters) initialising error RAM erroneous E 2
no crane operation possible
with regular occurrence --> replace ZE
000013 ZE 0: system error OS-HC11 (observe parameters) test total in EPROM/FLASH erroneous E 2
entry in error memory, all crane movements will be stopped
check program memory card
002389508 1
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
000017 ZE 0: system error OS-HC11 (observe parameters) total of CPU-time distribution too great E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
000018 ZE 0: system error OS-HC11 (observe parameters) arithmetic overflow (16 Bit) E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
000019 ZE 0: system error OS-HC11 (observe parameters) division through zero (16 Bit) E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
000023 ZE 0: system error OS-HC11 (observe parameters) program incapable of running (type identification) E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
002389508 2
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
000044 ZE 0: system error OS-HC11 (observe parameters) output parameter without effect, from inactive output E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
000045 ZE 0: system error OS-HC11 (observe parameters) entry parameter undefined, from inactive input E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
000047 ZE 0: system error OS-HC11 (observe parameters) realtime-control block not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
000049 ZE 0: system error OS-HC11 (observe parameters) urgent modul, ZE not available E 2
entry in error memory, no crane operation possible
check ZE
002389508 3
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
000052 ZE 0: system error OS-HC11 (observe parameters) file not open on close E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
000053 ZE 0: system error OS-HC11 (observe parameters) system mask not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
000054 ZE 0: system error OS-HC11 (observe parameters) system text not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
000057 ZE 0: system error OS-HC11 (observe parameters) default load chart missing E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
000058 ZE 0: system error OS-HC11 (observe parameters) amplifier erroneous or return power feed E 2
entry in error memory, all crane movements will be stopped
check wiring
002389508 4
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
000066 ZE 0: system error OS-HC11 (observe parameters) ADC working outside the permissible tolerance E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE
000067 ZE 0: system error OS-HC11 (observe parameters) arithmetic processor not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE
002389508 5
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
000074 ZE 0: system error OS-HC11 (observe parameters) transformation ASCII to BIN erroneous E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE
000076 ZE 0: system error OS-HC11 (observe parameters) incorrectly inserted power unit E 2
entry in error memory, all crane movements will be stopped
check memory card in power supply unit
000080 ZE 0: system error OS-HC11 (observe parameters) fatal internal software error E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE
002389508 6
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
000094 ZE 0: system error OS-HC11 (observe parameters) transmission error parallel bus E 2
entry in error memory, all crane movements will be stopped
check ZE, bus circuit board, power supply unit
002002 ZE 0: system error OS-TMS initialising error test total in EPROM/FLASH erroneous E 2
entry of error in error memory, all crane movements will be stopped
replace ZE
002389508 7
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
010073 ZE 0: output 0 open circuit or short circuit to supply voltage/ground X70:16 O-76.3 E 1
entry in error list
re-start, check lines
010173 ZE 0: output 1 open circuit or short circuit to supply voltage/ground X70:17 O-79.3 E 1
entry in error list
re-start, check lines
010260 ZE 0: output 2 safety chain error, diode defect or safety contact sticking X70:18 O-69.1 E 1
report of error, otherwise no reaction
checking of safety contact and diode
002389508 8
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
010273 ZE 0: output 2 open circuit or short circuit to supply voltage/ground X70:18 O-69.1 E 1
entry in error list
re-start, check lines
010360 ZE 0: output 3 safety chain error, diode defect or safety contact sticking X70:19 O-75.4 E 1
report of error, otherwise no reaction
checking of safety contact and diode
010373 ZE 0: output 3 open circuit or short circuit to supply voltage/ground X70:19 O-75.4 E 1
entry in error list
re-start, check lines
002389508 9
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
010560 ZE 0: output 5 safety chain error, diode defect or safety contact sticking X70:21 O-75.5 E 1
report of error, otherwise no reaction
checking of safety contact and diode
010573 ZE 0: output 5 open circuit or short circuit to supply voltage/ground X70:21 O-75.5 E 1
entry in error list
re-start, check lines
010660 ZE 0: output 6 safety chain error, diode defect or safety contact sticking X70:22 O-75.3 E 1
report of error, otherwise no reaction
checking of safety contact and diode
002389508 10
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
010673 ZE 0: output 6 open circuit or short circuit to supply voltage/ground X70:22 O-75.3 E 1
entry in error list
re-start, check lines
010760 ZE 0: output 7 safety chain error, diode defect or safety contact sticking X70:23 O-75.1 E 1
report of error, otherwise no reaction
checking of safety contact and diode
010773 ZE 0: output 7 open circuit or short circuit to supply voltage/ground X70:23 O-75.1 E 1
entry in error list
re-start, check lines
002389508 11
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
020050 ZE 0: LSB participant address 0 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
020051 ZE 0: LSB participant address 0 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
020053 ZE 0: LSB participant address 0 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
020054 ZE 0: LSB participant address 0 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
020064 ZE 0: LSB participant address 0 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
020065 ZE 0: LSB participant address 0 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
020066 ZE 0: LSB participant address 0 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
002389508 12
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
020150 ZE 0: LSB participant address 1 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
020151 ZE 0: LSB participant address 1 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
020153 ZE 0: LSB participant address 1 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
020154 ZE 0: LSB participant address 1 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
020164 ZE 0: LSB participant address 1 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
020165 ZE 0: LSB participant address 1 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
020166 ZE 0: LSB participant address 1 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
020250 ZE 0: LSB participant address 2 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
020251 ZE 0: LSB participant address 2 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
002389508 13
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
020253 ZE 0: LSB participant address 2 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
020254 ZE 0: LSB participant address 2 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
020263 ZE 0: LSB participant address 2 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
020264 ZE 0: LSB participant address 2 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
020265 ZE 0: LSB participant address 2 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
020266 ZE 0: LSB participant address 2 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
020350 ZE 0: LSB participant address 3 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
020351 ZE 0: LSB participant address 3 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
020353 ZE 0: LSB participant address 3 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
002389508 14
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
020354 ZE 0: LSB participant address 3 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
020363 ZE 0: LSB participant address 3 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
020364 ZE 0: LSB participant address 3 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
020365 ZE 0: LSB participant address 3 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
020366 ZE 0: LSB participant address 3 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
020450 ZE 0: LSB participant address 4 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
020451 ZE 0: LSB participant address 4 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
020453 ZE 0: LSB participant address 4 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
020454 ZE 0: LSB participant address 4 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
002389508 15
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
020463 ZE 0: LSB participant address 4 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
020464 ZE 0: LSB participant address 4 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
020465 ZE 0: LSB participant address 4 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
020466 ZE 0: LSB participant address 4 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
020550 ZE 0: LSB participant address 5 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
020551 ZE 0: LSB participant address 5 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
020553 ZE 0: LSB participant address 5 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
020554 ZE 0: LSB participant address 5 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
020563 ZE 0: LSB participant address 5 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
002389508 16
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
020564 ZE 0: LSB participant address 5 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
020565 ZE 0: LSB participant address 5 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
020566 ZE 0: LSB participant address 5 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
020650 ZE 0: LSB participant address 6 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
020651 ZE 0: LSB participant address 6 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
020653 ZE 0: LSB participant address 6 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
020654 ZE 0: LSB participant address 6 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
020663 ZE 0: LSB participant address 6 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
020664 ZE 0: LSB participant address 6 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
002389508 17
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
020665 ZE 0: LSB participant address 6 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
020666 ZE 0: LSB participant address 6 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
021050 ZE 0: LSB participant address 10 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
021051 ZE 0: LSB participant address 10 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
021053 ZE 0: LSB participant address 10 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
021054 ZE 0: LSB participant address 10 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
002389508 18
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
021063 ZE 0: LSB participant address 10 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
021064 ZE 0: LSB participant address 10 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
021065 ZE 0: LSB participant address 10 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
021066 ZE 0: LSB participant address 10 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
021150 ZE 0: LSB participant address 11 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
021151 ZE 0: LSB participant address 11 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
002389508 19
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
021153 ZE 0: LSB participant address 11 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
021154 ZE 0: LSB participant address 11 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
021163 ZE 0: LSB participant address 11 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
021164 ZE 0: LSB participant address 11 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
021165 ZE 0: LSB participant address 11 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
021166 ZE 0: LSB participant address 11 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
022150 ZE 0: LSB participant address 21 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
022151 ZE 0: LSB participant address 21 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
022153 ZE 0: LSB participant address 21 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
002389508 20
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
022154 ZE 0: LSB participant address 21 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
022163 ZE 0: LSB participant address 21 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
022164 ZE 0: LSB participant address 21 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
022165 ZE 0: LSB participant address 21 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
022166 ZE 0: LSB participant address 21 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
022250 ZE 0: LSB participant address 22 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
022251 ZE 0: LSB participant address 22 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
022253 ZE 0: LSB participant address 22 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
022254 ZE 0: LSB participant address 22 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
002389508 21
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
022263 ZE 0: LSB participant address 22 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
022264 ZE 0: LSB participant address 22 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
022265 ZE 0: LSB participant address 22 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
022266 ZE 0: LSB participant address 22 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
022350 ZE 0: LSB participant address 23 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
022351 ZE 0: LSB participant address 23 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
022353 ZE 0: LSB participant address 23 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
022354 ZE 0: LSB participant address 23 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
022363 ZE 0: LSB participant address 23 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
002389508 22
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
022364 ZE 0: LSB participant address 23 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
022365 ZE 0: LSB participant address 23 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
022366 ZE 0: LSB participant address 23 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
022450 ZE 0: LSB participant address 24 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
022451 ZE 0: LSB participant address 24 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
022453 ZE 0: LSB participant address 24 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
022454 ZE 0: LSB participant address 24 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
022463 ZE 0: LSB participant address 24 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
022464 ZE 0: LSB participant address 24 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
002389508 23
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
022465 ZE 0: LSB participant address 24 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
022466 ZE 0: LSB participant address 24 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
022550 ZE 0: LSB participant address 25 reports an incorrect sensor type X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
022551 ZE 0: LSB participant address 25 was not configured for the block transfer X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
022553 ZE 0: LSB participant address 25 no longer reports or withdrawn during running period X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
022554 ZE 0: LSB participant address 25 Features other settings (parameters) as pre-entered set values X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
022563 ZE 0: LSB participant address 25 not available or open line X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
022564 ZE 0: LSB participant address 25 reports tolerable error in self-test X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
022565 ZE 0: LSB participant address 25 reports intolerable error in self-test X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
002389508 24
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
022566 ZE 0: LSB participant address 25 with software version, that is no longer compatible X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
023206 ZE 0: Control data transfer LSB line connection to participant disrupted/not plugged in X635:z14/z16 O-52.4/52.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check bus connections, if connections OK despite error then check sensor and replace if necessary
023252 ZE 0: Control data transfer LSB has recognised Bus collisions, communication interrupted X635:z14/z16 O-52.4/52.4 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor
023255 ZE 0: Control data transfer LSB Bus connection faulty/defect, short circuit to supply voltage X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
023256 ZE 0: Control data transfer LSB Bus connection faulty/defect, no supply/short circuit to earth X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
023257 ZE 0: Control data transfer LSB has recognised network re-set (data transfer starts again) X635:z14/z16 O-52.4/52.4 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part
023258 ZE 0: Control data transfer LSB recognised participant with incorrect baud rate in bus X635:z14/z16 O-52.4/52.4 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors
023259 ZE 0: Control data transfer LSB recognised communication breakdown in bus X635:z14/z16 O-52.4/52.4 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network
023260 ZE 0: Control data transfer LSB driver error: no order to carry out X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software
002389508 25
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
023261 ZE 0: Control data transfer LSB driver error: undefined message appears X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination
023262 ZE 0: Control data transfer LSB driver error: initialising error X635:z14/z16 O-52.4/52.4 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination
025102 ZE 0: input 3 sensor deficiency data short circuit to supply voltage X635:d8 E 1
report of error, otherwise no reaction
check supply, LICCON input, sensor lines to short or break, sensor
025202 ZE 0: input 4 sensor deficiency data short circuit to supply voltage X635:d10 E 1
report of error, otherwise no reaction
check supply, LICCON input, sensor lines to short or break, sensor
002389508 26
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
030041 ZE 0: LMB all data for actual operation mode not available B 3
program stop
install new data memory card with corrected charts
030052 ZE 0: LMB re-fitting with load more than 0.5t and utilization larger 20% B 1
load chart cannot be entered through OK-key
put load to ground or switch crane off and on again
002389508 27
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
030064 ZE 0: LMB measured overall torque smaller than half torque without charge B 2
LMB-Stop: Load torque increasing movements cannot be affected
move boom out of danger zone or check sensor (angle-, pressure-, length),if load or radius indication incorrect
030067 ZE 0: LMB STOP, difference between length sensors 1 and 2 too great B 2
LMB-Stop: Load torque increasing movements cannot be affected
set the correct length sensors zero point
030079 ZE 0: LMB STOP, adjusted op. mode and crane configuration not identical B 2
LMB-Stop: Load torque increasing movements cannot be affected
set up crane according to selected operation mode
002389508 28
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
030122 ZE 0: LMB STOP, end of stroke switch 2 in auxiliary boom op. not connected E 2
LMB-Stop: Load torque increasing movements cannot be affected
connect end of stroke switch 2, or check limit switch or supply line
030124 ZE 0: LMB STOP, end of stroke switch 3 in auxiliary boom op. not connected E 2
LMB-Stop: Load torque increasing movements cannot be affected
connect end of stroke switch 3, or check limit switch or supply line
030130 ZE 0: LMB STOP, hoist limit switch 4 with 2 winch device not connected B
030135 ZE 0: LMB permissible deviation of data A/B tension meas. bracket 1 exceeded E 2
LMB-Stop: Load torque increasing movements cannot be affected
check connecting brackets or power supply, different stress flow into both connecting brackets possible
030136 ZE 0: LMB permissible deviation of data A/B tension meas. bracket 2 exceeded E 2
LMB-Stop: Load torque increasing movements cannot be affected
check connecting brackets or power supply, different stress flow into both connecting brackets possible
030137 ZE 0: LMB permissible deviation of data A/B tension meas. bracket 3 exceeded E 2
LMB-Stop: Load torque increasing movements cannot be affected
check connecting brackets or power supply, different stress flow into both connecting brackets possible
030147 ZE 0: LMB working radius list in load chart with incorrect value B 2
LMB-Stop: Load torque increasing movements cannot be affected
install new data memory card with corrected charts
002389508 29
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
030153 ZE 0: LMB selected attachment config. not corresponding with actual condition B 2
LMB-Stop: Load torque increasing movements cannot be affected
select load chart corresponding to actual crane configuration
030157 ZE 0: LMB selected slewing range not corresponding with actual condition B 2
LMB-Stop: Load torque increasing movements cannot be affected
enter chart that corresponds to the actual slewing range
002389508 30
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
030165 ZE 0: LMB difference between upper/lower angle sensor tele too great E 2
LMB-Stop: Load torque increasing movements cannot be affected
retrieve crane deflection through unloading, or check both angle sensors or their lines
030182 ZE 0: LMB difference between angle sensor cylinder lower/upper too great E 2
LMB-Stop: Load torque increasing movements cannot be affected
retrieve crane deflection through unloading, or check both angle sensors or their lines
030187 ZE 0: LMB actual slewing range different from set slewing range B 2
LMB-Stop: Load torque increasing movements cannot be affected
enter chart according to actual slewing angle of the boom
030190 ZE 0: LMB angle sensor error: load, reach, pulley head height indication defect E 2
LMB-Stop: Load torque increasing movements cannot be affected
check LSB-connection, angle sensor
032800 ZE 0: control slewing No swing movement recognised with selected swing gear E 1
002389508 31
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
033941 ZE 0: crane control Emergency operation switched on, Caution shut-downs ineffective B
034313 ZE 0: instruments armrest left master switch 2X both dir. contacts standing by simultaneously E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board
034315 ZE 0: instruments armrest left master switch 2X directional contact without zero contact E 1
output of error, shut-down through application
check supply, LICCON input, sensor lines for breaks , check defect sensor
034317 ZE 0: instruments armrest left master switch 2X analogue signal short to supply voltage E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board
034321 ZE 0: instruments armrest left master switch 2X analogue sig. open circuit or short to ground E 1
output of error, shut-down through application
check supply, LICCON input, sensor line for breaks , defect sensor through withdrawing of sensor
002389508 32
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
034833 ZE 0: control diagnosis system Pressure cut-off swing gear outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure hoist gear, carry out test program again
034856 ZE 0: control diagnosis system slewing gear turning with closed brakes E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
034857 ZE 0: control diagnosis system Initial current swing gear right above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
034858 ZE 0: control diagnosis system Initial current swing gear right below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
034859 ZE 0: control diagnosis system Initial current swing gear left above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
034860 ZE 0: control diagnosis system Initial current swing gear left below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
034861 ZE 0: control diagnosis system slewing speed right slewing gear too low E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
034862 ZE 0: control diagnosis system slewing speed right slewing gear too high E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
034863 ZE 0: control diagnosis system slewing speed left slewing gear too low E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
034864 ZE 0: control diagnosis system slewing speed left slewing gear too high E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
002389508 33
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
034865 ZE 0: control diagnosis system Hysteresis right-hand swing gear too great E 1
Carrying out of test program delayed / interrupted
Check proportional-flow valve
034866 ZE 0: control diagnosis system Hysteresis left-hand swing gear too great E 1
Carrying out of test program delayed / interrupted
Check proportional-flow valve
035808 ZE 0: operation slewing shut-down slewing right working area limitation ABB B
035809 ZE 0: operation slewing shut-down slewing left working area limitation ABB B
002389508 34
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
035890 ZE 0: operation slewing Slewing platform not bolted or impermissible bolting condition B 1
report of error, otherwise no reaction
Correct bolting position, check position ok: -supply, -input LICCON, -sensor line for short-circuit, -sensor
037049 ZE 0: operation instruments crane operators cab seat contact not activated, crane movements blocked B 1
output of error, shut-down through application
sit down (seat limit switch) or dead man (in master switch) or check LICCON input, sensor lines, sensor
037313 ZE 0: operation instruments armrest left master switch 2X not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor
039800 ZE 0: operation diagnosis system interruption, master switch defective or incorrectly deflected B 1
Carrying out of test program delayed / interrupted
Note direction of movements, carry out test program again
039803 ZE 0: operation diagnosis system Break, incorrect/faulty bolting condition swing gear B 1
Carrying out of test program delayed / interrupted
Unbolt slewing platform or check swing signals
039814 ZE 0: operation diagnosis system Alignment aid not correctly shut down B 1
Invalid operation condition, no proper crane operation possible
Apply F key, end active test program
039820 ZE 0: operation diagnosis system interruption, boom angle beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct luffing position, carry out test program again
002389508 35
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
039821 ZE 0: operation diagnosis system interruption, tele length beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct telescopic boom length length, carry out test program again
039822 ZE 0: operation diagnosis system interruption, hook load beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Note max. hook load, carry out test program again
100001 ZE 1: system error OS-HC11 (observe parameters) initialising error processor-register erroneous E 2
no crane operation possible
check program memory card or ZE
100002 ZE 1: system error OS-HC11 (observe parameters) initialising error test total in EPROM/FLASH erroneous E 2
no crane operation possible
100006 ZE 1: system error OS-HC11 (observe parameters) initialising error RAM erroneous E 2
no crane operation possible
with regular occurrence --> replace ZE
002389508 36
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
100013 ZE 1: system error OS-HC11 (observe parameters) test total in EPROM/FLASH erroneous E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
100017 ZE 1: system error OS-HC11 (observe parameters) total of CPU-time distribution too great E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
100018 ZE 1: system error OS-HC11 (observe parameters) arithmetic overflow (16 Bit) E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
100019 ZE 1: system error OS-HC11 (observe parameters) division through zero (16 Bit) E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
002389508 37
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
100023 ZE 1: system error OS-HC11 (observe parameters) program incapable of running (type identification) E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
100044 ZE 1: system error OS-HC11 (observe parameters) output parameter without effect, from inactive output E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
100045 ZE 1: system error OS-HC11 (observe parameters) entry parameter undefined, from inactive input E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
100047 ZE 1: system error OS-HC11 (observe parameters) realtime-control block not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
002389508 38
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
100049 ZE 1: system error OS-HC11 (observe parameters) urgent modul, ZE not available E 2
entry in error memory, no crane operation possible
with regular occurrence --> notify after-sales service
100052 ZE 1: system error OS-HC11 (observe parameters) file not open on close E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
100053 ZE 1: system error OS-HC11 (observe parameters) system mask not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
100054 ZE 1: system error OS-HC11 (observe parameters) system text not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
100057 ZE 1: system error OS-HC11 (observe parameters) default load chart missing E 2
entry in error memory, all crane movements will be stopped
check wiring
002389508 39
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
100058 ZE 1: system error OS-HC11 (observe parameters) amplifier erroneous or return power feed E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
100066 ZE 1: system error OS-HC11 (observe parameters) ADC working outside the permissible tolerance E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE
100067 ZE 1: system error OS-HC11 (observe parameters) arithmetic processor not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE
002389508 40
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
100074 ZE 1: system error OS-HC11 (observe parameters) transformation ASCII to BIN erroneous E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE
100076 ZE 1: system error OS-HC11 (observe parameters) incorrectly inserted power unit E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE
002389508 41
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
100080 ZE 1: system error OS-HC11 (observe parameters) fatal internal software error E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE
100094 ZE 1: system error OS-HC11 (observe parameters) transmission error parallel bus E 2
entry in error memory, all crane movements will be stopped
102002 ZE 1: system error OS-TMS initialising error test total in EPROM/FLASH erroneous E 2
entry of error in error memory, all crane movements will be stopped
replace ZE
002389508 42
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
110073 ZE 1: output 0 open circuit or short circuit to supply voltage/ground X71:16 O-70.3 E 1
entry in error list
re-start, check lines
002389508 43
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
110173 ZE 1: output 1 open circuit or short circuit to supply voltage/ground X71:17 O-70.4 E 1
entry in error list
re-start, check lines
110260 ZE 1: output 2 safety chain error, diode defect or safety contact sticking X71:18 O-69.6 E 1
report of error, otherwise no reaction
checking of safety contact and diode
110273 ZE 1: output 2 open circuit or short circuit to supply voltage/ground X71:18 O-69.6 E 1
entry in error list
re-start, check lines
110360 ZE 1: output 3 safety chain error, diode defect or safety contact sticking X71:19 O-69.7 E 1
report of error, otherwise no reaction
checking of safety contact and diode
002389508 44
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
110373 ZE 1: output 3 open circuit or short circuit to supply voltage/ground X71:19 O-69.7 E 1
entry in error list
re-start, check lines
110460 ZE 1: output 4 safety chain error, diode defect or safety contact sticking X71:20 O-64.5 E 1
report of error, otherwise no reaction
checking of safety contact and diode
110473 ZE 1: output 4 open circuit or short circuit to supply voltage/ground X71:20 O-64.5 E 1
entry in error list
re-start, check lines
110560 ZE 1: output 5 safety chain error, diode defect or safety contact sticking X71:21 E 1
report of error, otherwise no reaction
checking of safety contact and diode
002389508 45
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
110660 ZE 1: output 6 safety chain error, diode defect or safety contact sticking X71:22 O-69.5 E 1
report of error, otherwise no reaction
checking of safety contact and diode
110673 ZE 1: output 6 open circuit or short circuit to supply voltage/ground X71:22 O-69.5 E 1
entry in error list
re-start, check lines
110760 ZE 1: output 7 safety chain error, diode defect or safety contact sticking X71:23 O-69.3 E 1
report of error, otherwise no reaction
checking of safety contact and diode
002389508 46
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
110773 ZE 1: output 7 open circuit or short circuit to supply voltage/ground X71:23 O-69.3 E 1
entry in error list
re-start, check lines
120050 ZE 1: LSB participant address 0 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
120051 ZE 1: LSB participant address 0 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
120053 ZE 1: LSB participant address 0 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
120054 ZE 1: LSB participant address 0 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
002389508 47
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
120064 ZE 1: LSB participant address 0 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
120065 ZE 1: LSB participant address 0 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
120066 ZE 1: LSB participant address 0 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
120150 ZE 1: LSB participant address 1 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
120151 ZE 1: LSB participant address 1 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
120153 ZE 1: LSB participant address 1 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
120154 ZE 1: LSB participant address 1 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
120164 ZE 1: LSB participant address 1 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
120165 ZE 1: LSB participant address 1 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
002389508 48
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
120166 ZE 1: LSB participant address 1 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
121050 ZE 1: LSB participant address 10 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
121051 ZE 1: LSB participant address 10 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
121053 ZE 1: LSB participant address 10 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
121054 ZE 1: LSB participant address 10 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
121063 ZE 1: LSB participant address 10 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
002389508 49
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
121064 ZE 1: LSB participant address 10 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
121065 ZE 1: LSB participant address 10 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
121066 ZE 1: LSB participant address 10 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
121150 ZE 1: LSB participant address 11 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
121151 ZE 1: LSB participant address 11 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
121153 ZE 1: LSB participant address 11 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
002389508 50
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
121154 ZE 1: LSB participant address 11 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
121163 ZE 1: LSB participant address 11 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
121164 ZE 1: LSB participant address 11 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
121165 ZE 1: LSB participant address 11 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
121166 ZE 1: LSB participant address 11 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
121250 ZE 1: LSB participant address 12 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
002389508 51
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
121251 ZE 1: LSB participant address 12 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
121253 ZE 1: LSB participant address 12 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
121254 ZE 1: LSB participant address 12 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
121263 ZE 1: LSB participant address 12 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
121264 ZE 1: LSB participant address 12 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
121265 ZE 1: LSB participant address 12 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
121266 ZE 1: LSB participant address 12 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
002389508 52
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
121350 ZE 1: LSB participant address 13 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
121351 ZE 1: LSB participant address 13 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
121353 ZE 1: LSB participant address 13 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
121354 ZE 1: LSB participant address 13 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
121363 ZE 1: LSB participant address 13 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
121364 ZE 1: LSB participant address 13 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
121365 ZE 1: LSB participant address 13 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
121366 ZE 1: LSB participant address 13 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
002389508 53
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
121450 ZE 1: LSB participant address 14 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
121451 ZE 1: LSB participant address 14 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
121453 ZE 1: LSB participant address 14 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
121454 ZE 1: LSB participant address 14 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
121463 ZE 1: LSB participant address 14 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
121464 ZE 1: LSB participant address 14 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
121465 ZE 1: LSB participant address 14 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
002389508 54
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
121466 ZE 1: LSB participant address 14 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
121650 ZE 1: LSB participant address 16 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
121651 ZE 1: LSB participant address 16 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
121653 ZE 1: LSB participant address 16 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
121654 ZE 1: LSB participant address 16 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
121663 ZE 1: LSB participant address 16 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
002389508 55
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
121664 ZE 1: LSB participant address 16 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
121665 ZE 1: LSB participant address 16 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
121666 ZE 1: LSB participant address 16 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
121750 ZE 1: LSB participant address 17 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
121751 ZE 1: LSB participant address 17 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
121753 ZE 1: LSB participant address 17 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
002389508 56
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
121754 ZE 1: LSB participant address 17 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
121763 ZE 1: LSB participant address 17 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
121764 ZE 1: LSB participant address 17 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
121765 ZE 1: LSB participant address 17 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
121766 ZE 1: LSB participant address 17 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
121850 ZE 1: LSB participant address 18 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
002389508 57
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
121851 ZE 1: LSB participant address 18 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
121853 ZE 1: LSB participant address 18 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
121854 ZE 1: LSB participant address 18 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
121863 ZE 1: LSB participant address 18 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
121864 ZE 1: LSB participant address 18 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
121865 ZE 1: LSB participant address 18 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
121866 ZE 1: LSB participant address 18 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
002389508 58
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
121950 ZE 1: LSB participant address 19 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
121951 ZE 1: LSB participant address 19 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
121953 ZE 1: LSB participant address 19 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
121954 ZE 1: LSB participant address 19 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
121963 ZE 1: LSB participant address 19 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
121964 ZE 1: LSB participant address 19 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
121965 ZE 1: LSB participant address 19 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
121966 ZE 1: LSB participant address 19 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
002389508 59
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
122050 ZE 1: LSB participant address 20 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
122051 ZE 1: LSB participant address 20 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
122053 ZE 1: LSB participant address 20 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
122054 ZE 1: LSB participant address 20 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
122063 ZE 1: LSB participant address 20 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
122064 ZE 1: LSB participant address 20 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
122065 ZE 1: LSB participant address 20 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
002389508 60
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
122066 ZE 1: LSB participant address 20 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
122150 ZE 1: LSB participant address 21 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
122151 ZE 1: LSB participant address 21 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
122153 ZE 1: LSB participant address 21 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
122154 ZE 1: LSB participant address 21 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
122163 ZE 1: LSB participant address 21 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
002389508 61
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
122164 ZE 1: LSB participant address 21 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
122165 ZE 1: LSB participant address 21 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
122166 ZE 1: LSB participant address 21 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
122950 ZE 1: LSB participant address 29 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
122951 ZE 1: LSB participant address 29 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
122953 ZE 1: LSB participant address 29 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
122954 ZE 1: LSB participant address 29 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
122963 ZE 1: LSB participant address 29 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
122964 ZE 1: LSB participant address 29 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
002389508 62
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
122965 ZE 1: LSB participant address 29 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
122966 ZE 1: LSB participant address 29 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
123050 ZE 1: LSB participant address 30 reports an incorrect sensor type X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
123051 ZE 1: LSB participant address 30 was not configured for the block transfer X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
123053 ZE 1: LSB participant address 30 no longer reports or withdrawn during running period X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
123054 ZE 1: LSB participant address 30 Features other settings (parameters) as pre-entered set values X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
123063 ZE 1: LSB participant address 30 not available or open line X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
123064 ZE 1: LSB participant address 30 reports tolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
123065 ZE 1: LSB participant address 30 reports intolerable error in self-test X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
002389508 63
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
123066 ZE 1: LSB participant address 30 with software version, that is no longer compatible X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
123206 ZE 1: Control data transfer LSB line connection to participant disrupted/not plugged in X635A:z14/z16 O-53.4/53.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check bus connections, if connections OK despite error then check sensor and replace if necessary
123252 ZE 1: Control data transfer LSB has recognised Bus collisions, communication interrupted X635A:z14/z16 O-53.4/53.4 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor
123255 ZE 1: Control data transfer LSB Bus connection faulty/defect, short circuit to supply voltage X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
123256 ZE 1: Control data transfer LSB Bus connection faulty/defect, no supply/short circuit to earth X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
123257 ZE 1: Control data transfer LSB has recognised network re-set (data transfer starts again) X635A:z14/z16 O-53.4/53.4 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part
123258 ZE 1: Control data transfer LSB recognised participant with incorrect baud rate in bus X635A:z14/z16 O-53.4/53.4 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors
123259 ZE 1: Control data transfer LSB recognised communication breakdown in bus X635A:z14/z16 O-53.4/53.4 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network
123260 ZE 1: Control data transfer LSB driver error: no order to carry out X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software
002389508 64
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
123261 ZE 1: Control data transfer LSB driver error: undefined message appears X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination
123262 ZE 1: Control data transfer LSB driver error: initialising error X635A:z14/z16 O-53.4/53.4 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination
130570 ZE 1: remote control emergency operation telescoping movement selected with LICCON B 1
130611 ZE 1: Data recorder Start: Crane number faulty (not 9 figures numerically) E 1
Data recorder software stops - no documentation possible!
Define crane number correctly (Sxxxxxxx.yyQ - KNFttt00vvrr.Q)
002389508 65
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
132650 ZE 1: control telescoping Tele recognition faulty, more than one track switch reporting active E 1
134000 ZE 1: instruments crane operators cab master switch 3Y both dir. contacts standing by simultaneously E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board
002389508 66
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
134002 ZE 1: instruments crane operators cab master switch 3Y directional contact without zero contact E 1
output of error, shut-down through application
check supply, LICCON input, sensor lines for breaks , check defect sensor
134004 ZE 1: instruments crane operators cab master switch 3Y analogue signal short to supply voltage E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board
134008 ZE 1: instruments crane operators cab master switch 3Y analogue signal open circuit or short to ground E 1
output of error, shut-down through application
check supply, LICCON input, sensor line for breaks , defect sensor through withdrawing of sensor
134201 ZE 1: instruments armrest right master switch 1X both dir. contacts standing by simultaneously E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board
134203 ZE 1: instruments armrest right master switch 1X directional contact without zero contact E 1
output of error, shut-down through application
check supply, LICCON input, sensor lines for breaks , check defect sensor
134205 ZE 1: instruments armrest right master switch 1X analogue signal short to supply voltage E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board
134209 ZE 1: instruments armrest right master switch 1X analogue sig. open circuit or short circ. to ground E 1
output of error, shut-down through application
check supply, LICCON input, sensor line for breaks , defect sensor through withdrawing of sensor
134312 ZE 1: instruments armrest left master switch 2Y both dir. contacts standing by simultaneously E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board
134314 ZE 1: instruments armrest left master switch 2Y directional contact without zero contact E 1
output of error, shut-down through application
check supply, LICCON input, sensor lines for breaks , check defect sensor
134316 ZE 1: instruments armrest left master switch 2Y analogue signal short to supply voltage E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board
002389508 67
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
134320 ZE 1: instruments armrest left master switch 2Y analogue sig. open circuit or short to ground E 1
output of error, shut-down through application
check supply, LICCON input, sensor line for breaks , defect sensor through withdrawing of sensor
134834 ZE 1: control diagnosis system Pressure cut-off cylinder out outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure cylinder Off, carry out test program again
134835 ZE 1: control diagnosis system Pressure cut-off tele out outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure telescopic boom length Off, carry out test program again
134836 ZE 1: control diagnosis system Pressure cut-off cylinder in outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure cylinder On, carry out test program again
134837 ZE 1: control diagnosis system Pressure cut-off tele in outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure telescopic boom length On, carry out test program again
134877 ZE 1: control diagnosis system Initial current telescoping in above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
134878 ZE 1: control diagnosis system Initial current telescoping in below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
002389508 68
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
134879 ZE 1: control diagnosis system Initial current telescoping out above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
134880 ZE 1: control diagnosis system Initial current telescoping out below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
134883 ZE 1: control diagnosis system Speed telescoping out below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
134884 ZE 1: control diagnosis system Speed telescoping out above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
134886 ZE 1: control diagnosis system Hysteresis telescoping out outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check proportional-flow valve
135608 ZE 1: operation telescoping shut-down tele OUT main boom working area limitation ABB B
135609 ZE 1: operation telescoping shut-down tele IN main boom working area limitation ABB B
002389508 69
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
002389508 70
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
135660 ZE 1: operation telescoping unbolting telescope not possible, cylinder is not bolted B
135663 ZE 1: operation telescoping unbolting cylinder not possible, telescope is not bolted B
135664 ZE 1: operation telescoping unbolting cylinder not possible, automatic system adjusted B
135665 ZE 1: operation telescoping unbolting telescope not possible, automatic system adjusted B
002389508 71
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
135690 ZE 1: operation telescoping cylinder bolting is neither unpinned nor in a pivot section B
137049 ZE 1: operation instruments crane operators cab seat contact not activated, crane movements blocked B 1
output of error, shut-down through application
sit down (seat limit switch) or dead man (in master switch) or check LICCON input, sensor lines, sensor
137201 ZE 1: operation instruments armrest right master switch 1X not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor
137312 ZE 1: operation instruments armrest left master switch 2Y not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor
139800 ZE 1: operation diagnosis system interruption, master switch defective or incorrectly deflected B 1
Carrying out of test program delayed / interrupted
Note direction of movements, carry out test program again
002389508 72
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
139804 ZE 1: operation diagnosis system Termination, change-over luff/telescoping incorrect switch position B 1
Carrying out of test program delayed / interrupted
Turn change-over luff./ tele. to correctly corresponding switch pos. ,erase error, actuate Reset and start again
139812 ZE 1: operation diagnosis system Termination, windable rope length too short B 1
Carrying out of test program delayed / interrupted
Check reeving wind off more rope, carry out test program again
139814 ZE 1: operation diagnosis system Alignment aid not correctly shut down B 1
Invalid operation condition, no proper crane operation possible
Apply F key, end active test program
139815 ZE 1: operation diagnosis system Switch over telescoping to operation type "Manual" B 1
Carrying out of test program delayed / interrupted
Change over to manual operation telescoping, erase error, actuate Reset and start again
139820 ZE 1: operation diagnosis system interruption, boom angle beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct luffing position, carry out test program again
139821 ZE 1: operation diagnosis system interruption, tele length beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct telescopic boom length length, carry out test program again
139822 ZE 1: operation diagnosis system interruption, hook load beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Note max. hook load, carry out test program again
002389508 73
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
139825 ZE 1: operation diagnosis system Termination, cylinder length outside of prescribed areas B 1
Carrying out of test program delayed / interrupted
Start up correct cylinder length (preferably with 100% bolted), carry out test program again
161002 E/A-Modul 1: system error OS-C167 initialising error test total in EPROM/FLASH erroneous E 2
error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul
002389508 74
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
172052 E/A-Modul 1: input/output DEA0 output open, to low load, short circuit to supply voltage X613:17 U-72.2 E 3
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
172053 E/A-Modul 1: input/output DEA0 transistor current supply insufficient or missing X613:17 U-72.2 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
172054 E/A-Modul 1: input/output DEA0 short circuit to supply voltage X613:17 U-72.2 E 1
error report on display
check output for short, if necessary replace E/A-Modul
172055 E/A-Modul 1: input/output DEA0 excessive temperature, short circuit to ground or overload X613:17 U-72.2 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
172152 E/A-Modul 1: input/output DEA1 output open, to low load, short circuit to supply voltage X613:15 U-72.3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
172153 E/A-Modul 1: input/output DEA1 transistor current supply insufficient or missing X613:15 U-72.3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
172154 E/A-Modul 1: input/output DEA1 short circuit to supply voltage X613:15 U-72.3 E 1
error report on display
check output for short, if necessary replace E/A-Modul
172155 E/A-Modul 1: input/output DEA1 excessive temperature, short circuit to ground or overload X613:15 U-72.3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
172252 E/A-Modul 1: input/output DEA2 output open, to low load, short circuit to supply voltage X613:13 U-72.4 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
172253 E/A-Modul 1: input/output DEA2 transistor current supply insufficient or missing X613:13 U-72.4 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
002389508 75
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
172254 E/A-Modul 1: input/output DEA2 short circuit to supply voltage X613:13 U-72.4 E 1
error report on display
check output for short, if necessary replace E/A-Modul
172255 E/A-Modul 1: input/output DEA2 excessive temperature, short circuit to ground or overload X613:13 U-72.4 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
172352 E/A-Modul 1: input/output DEA3 output open, to low load, short circuit to supply voltage X613:11 U-72.5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
172353 E/A-Modul 1: input/output DEA3 transistor current supply insufficient or missing X613:11 U-72.5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
172354 E/A-Modul 1: input/output DEA3 short circuit to supply voltage X613:11 U-72.5 E 1
error report on display
check output for short, if necessary replace E/A-Modul
172355 E/A-Modul 1: input/output DEA3 excessive temperature, short circuit to ground or overload X613:11 U-72.5 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
172452 E/A-Modul 1: input/output DEA4 output open, to low load, short circuit to supply voltage X613:9 U-72.6 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
172453 E/A-Modul 1: input/output DEA4 transistor current supply insufficient or missing X613:9 U-72.6 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
172454 E/A-Modul 1: input/output DEA4 short circuit to supply voltage X613:9 U-72.6 E 1
error report on display
check output for short, if necessary replace E/A-Modul
172455 E/A-Modul 1: input/output DEA4 excessive temperature, short circuit to ground or overload X613:9 U-72.6 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
002389508 76
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
172552 E/A-Modul 1: input/output DEA5 output open, to low load, short circuit to supply voltage X613:7 U-72.6 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
172553 E/A-Modul 1: input/output DEA5 transistor current supply insufficient or missing X613:7 U-72.6 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
172554 E/A-Modul 1: input/output DEA5 short circuit to supply voltage X613:7 U-72.6 E 1
error report on display
check output for short, if necessary replace E/A-Modul
172555 E/A-Modul 1: input/output DEA5 excessive temperature, short circuit to ground or overload X613:7 U-72.6 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
172652 E/A-Modul 1: input/output DEA6 output open, to low load, short circuit to supply voltage X613:5 U-72.7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
172653 E/A-Modul 1: input/output DEA6 transistor current supply insufficient or missing X613:5 U-72.7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
172654 E/A-Modul 1: input/output DEA6 short circuit to supply voltage X613:5 U-72.7 E 1
error report on display
check output for short, if necessary replace E/A-Modul
172655 E/A-Modul 1: input/output DEA6 excessive temperature, short circuit to ground or overload X613:5 U-72.7 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
172752 E/A-Modul 1: input/output DEA7 output open, to low load, short circuit to supply voltage X613:3 U-72.8 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
172753 E/A-Modul 1: input/output DEA7 transistor current supply insufficient or missing X613:3 U-72.8 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
002389508 77
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
172754 E/A-Modul 1: input/output DEA7 short circuit to supply voltage X613:3 U-72.8 E 1
error report on display
check output for short, if necessary replace E/A-Modul
172755 E/A-Modul 1: input/output DEA7 excessive temperature, short circuit to ground or overload X613:3 U-72.8 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
173481 E/A-Modul 1: voltage input E4 short circuit to supply voltage, open line X612:9 U-67.3 E 1
symbol for brake pressure 1 is flashing on the display unit
check input signal on the E/A-Modul or sensor
173581 E/A-Modul 1: voltage input E5 short circuit to supply voltage, open line X612:7 U-67.2 E 1
symbol for brake pressure 2 is flashing on the display unit
check input signal on the E/A-Modul or sensor
173782 E/A-Modul 1: voltage input E7 short circuit to ground, open line, constant current 10 mA incorrect X612:4 U-53.6 E 1
no reaction
check input signal on the E/A-Modul or sensor
173783 E/A-Modul 1: voltage input E7 short circuit to supply voltage, open line, lack of voltage X612:4 U-53.6 E 1
no reaction
check input signal on the E/A-Modul or sensor
179052 E/A-Modul 1: output A0 output open, to low load, short circuit to supply voltage X613:18 U-62.5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
179053 E/A-Modul 1: output A0 transistor current supply insufficient or missing X613:18 U-62.5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
179055 E/A-Modul 1: output A0 excessive temperature, short circuit to ground or overload X613:18 U-62.5 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
002389508 78
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
179152 E/A-Modul 1: output A1 output open, to low load, short circuit to supply voltage X613:16 U-53.5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
179153 E/A-Modul 1: output A1 transistor current supply insufficient or missing X613:16 U-53.5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
179155 E/A-Modul 1: output A1 excessive temperature, short circuit to ground or overload X613:16 U-53.5 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
179250 E/A-Modul 1: bridge output A2 short circuit to ground, junction not supplied X613:14 U-82.8 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul
179251 E/A-Modul 1: bridge output A2 short circuit to supply voltage, excessive temperature X613:14 U-82.8 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul
179252 E/A-Modul 1: bridge output A2 output open, to low load, short circuit to supply voltage X613:14 U-82.8 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
179253 E/A-Modul 1: bridge output A2 transistor current supply insufficient or missing X613:14 U-82.8 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
179254 E/A-Modul 1: bridge output A2 short circuit to supply voltage X613:14 U-82.8 E 1
error report on display
check output for short, if necessary replace E/A-Modul
179255 E/A-Modul 1: bridge output A2 excessive temperature, short circuit to ground or overload X613:14 U-82.8 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
002389508 79
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
179350 E/A-Modul 1: bridge output A3 short circuit to ground, junction not supplied X613:12 U-73.2 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul
179351 E/A-Modul 1: bridge output A3 short circuit to supply voltage, excessive temperature X613:12 U-73.2 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul
179352 E/A-Modul 1: bridge output A3 output open, to low load, short circuit to supply voltage X613:12 U-73.2 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
179353 E/A-Modul 1: bridge output A3 transistor current supply insufficient or missing X613:12 U-73.2 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
179354 E/A-Modul 1: bridge output A3 short circuit to supply voltage X613:12 U-73.2 E 1
error report on display
check output for short, if necessary replace E/A-Modul
179355 E/A-Modul 1: bridge output A3 excessive temperature, short circuit to ground or overload X613:12 U-73.2 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
183401 E/A-Modul 1: SPI-control unit Faulty data transfer E/A-module<>unit (time exceeded) X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
183402 E/A-Modul 1: SPI-control unit Serious system error to SPI-connection (interface) X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
183403 E/A-Modul 1: SPI-control unit break in line or short circuit to supply voltage X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary
183404 E/A-Modul 1: SPI-control unit break in line or short circuit to ground X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary
002389508 80
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
183406 E/A-Modul 1: SPI-control unit Data transfer faulty (faulty check byte) X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
suppress EMV- interference
183407 E/A-Modul 1: SPI-control unit Unit faulty/missing, incorrect unit inserted (ID) X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
check periphery and replace if necessary, check Software version, check EMV- interference
183408 E/A-Modul 1: SPI-control unit Data transfer faulty (incorrect number of data bytes received) X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
183900 E/A-Modul 1: Control operating unit (SPI) Faulty initialisation data connection E/A-module<>unit X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
183902 E/A-Modul 1: Control operating unit (SPI) Serious system error to SPI-connection (interface) X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
183905 E/A-Modul 1: Control operating unit (SPI) Initialisation error, resetting inputs/outputs faulty X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
check wiring, check periphery and replace if necessary, check E/A-Modul and replace if necessary
183907 E/A-Modul 1: Control operating unit (SPI) Unit faulty/missing, incorrect unit inserted (ID) X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
connect functional periphery unit, system then eliminates error independently
183908 E/A-Modul 1: Control operating unit (SPI) Data transfer faulty (incorrect number of data bytes received) X614:1/2/3/5/6/ U-47.7/47.6/47.5/47. E 1
error indication on display 7/8 4/47.4/47.3/47.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
184050 E/A-Modul 1: LSB-B participant address 0 reports an incorrect sensor type X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
184051 E/A-Modul 1: LSB-B participant address 0 was not configured for the block transfer X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
002389508 81
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
184053 E/A-Modul 1: LSB-B participant address 0 no longer reports or withdrawn during running period X613:4/6 U-46.3/46.2 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
184054 E/A-Modul 1: LSB-B participant address 0 Features other settings (parameters) as pre-entered set values X613:4/6 U-46.3/46.2 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
184064 E/A-Modul 1: LSB-B participant address 0 reports tolerable error in self-test X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
184065 E/A-Modul 1: LSB-B participant address 0 reports intolerable error in self-test X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
184066 E/A-Modul 1: LSB-B participant address 0 with software version, that is no longer compatible X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
184067 E/A-Modul 1: LSB-B participant address 0 supports no download function X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
184150 E/A-Modul 1: LSB-B participant address 1 reports an incorrect sensor type X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
184151 E/A-Modul 1: LSB-B participant address 1 was not configured for the block transfer X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
184153 E/A-Modul 1: LSB-B participant address 1 no longer reports or withdrawn during running period X613:4/6 U-46.3/46.2 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
184154 E/A-Modul 1: LSB-B participant address 1 Features other settings (parameters) as pre-entered set values X613:4/6 U-46.3/46.2 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
002389508 82
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
184164 E/A-Modul 1: LSB-B participant address 1 reports tolerable error in self-test X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
184165 E/A-Modul 1: LSB-B participant address 1 reports intolerable error in self-test X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
184166 E/A-Modul 1: LSB-B participant address 1 with software version, that is no longer compatible X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
184167 E/A-Modul 1: LSB-B participant address 1 supports no download function X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
184250 E/A-Modul 1: LSB-B participant address 2 reports an incorrect sensor type X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
184251 E/A-Modul 1: LSB-B participant address 2 was not configured for the block transfer X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
184253 E/A-Modul 1: LSB-B participant address 2 no longer reports or withdrawn during running period X613:4/6 U-46.3/46.2 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
184254 E/A-Modul 1: LSB-B participant address 2 Features other settings (parameters) as pre-entered set values X613:4/6 U-46.3/46.2 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
184264 E/A-Modul 1: LSB-B participant address 2 reports tolerable error in self-test X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
184265 E/A-Modul 1: LSB-B participant address 2 reports intolerable error in self-test X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
002389508 83
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
184266 E/A-Modul 1: LSB-B participant address 2 with software version, that is no longer compatible X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
184267 E/A-Modul 1: LSB-B participant address 2 supports no download function X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
184350 E/A-Modul 1: LSB-B participant address 3 reports an incorrect sensor type X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
184351 E/A-Modul 1: LSB-B participant address 3 was not configured for the block transfer X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
184353 E/A-Modul 1: LSB-B participant address 3 no longer reports or withdrawn during running period X613:4/6 U-46.3/46.2 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
184354 E/A-Modul 1: LSB-B participant address 3 Features other settings (parameters) as pre-entered set values X613:4/6 U-46.3/46.2 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
184364 E/A-Modul 1: LSB-B participant address 3 reports tolerable error in self-test X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
184365 E/A-Modul 1: LSB-B participant address 3 reports intolerable error in self-test X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
184366 E/A-Modul 1: LSB-B participant address 3 with software version, that is no longer compatible X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
184367 E/A-Modul 1: LSB-B participant address 3 supports no download function X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
002389508 84
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
184450 E/A-Modul 1: LSB-B participant address 4 reports an incorrect sensor type X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
184451 E/A-Modul 1: LSB-B participant address 4 was not configured for the block transfer X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
184453 E/A-Modul 1: LSB-B participant address 4 no longer reports or withdrawn during running period X613:4/6 U-46.3/46.2 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
184454 E/A-Modul 1: LSB-B participant address 4 Features other settings (parameters) as pre-entered set values X613:4/6 U-46.3/46.2 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
184464 E/A-Modul 1: LSB-B participant address 4 reports tolerable error in self-test X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
184465 E/A-Modul 1: LSB-B participant address 4 reports intolerable error in self-test X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
184466 E/A-Modul 1: LSB-B participant address 4 with software version, that is no longer compatible X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
184467 E/A-Modul 1: LSB-B participant address 4 supports no download function X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
184550 E/A-Modul 1: LSB-B participant address 5 reports an incorrect sensor type X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
184551 E/A-Modul 1: LSB-B participant address 5 was not configured for the block transfer X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
002389508 85
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
184553 E/A-Modul 1: LSB-B participant address 5 no longer reports or withdrawn during running period X613:4/6 U-46.3/46.2 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
184554 E/A-Modul 1: LSB-B participant address 5 Features other settings (parameters) as pre-entered set values X613:4/6 U-46.3/46.2 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
184564 E/A-Modul 1: LSB-B participant address 5 reports tolerable error in self-test X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
184565 E/A-Modul 1: LSB-B participant address 5 reports intolerable error in self-test X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
184566 E/A-Modul 1: LSB-B participant address 5 with software version, that is no longer compatible X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
184567 E/A-Modul 1: LSB-B participant address 5 supports no download function X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
184650 E/A-Modul 1: LSB-B participant address 6 reports an incorrect sensor type X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
184651 E/A-Modul 1: LSB-B participant address 6 was not configured for the block transfer X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
184653 E/A-Modul 1: LSB-B participant address 6 no longer reports or withdrawn during running period X613:4/6 U-46.3/46.2 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
184654 E/A-Modul 1: LSB-B participant address 6 Features other settings (parameters) as pre-entered set values X613:4/6 U-46.3/46.2 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
002389508 86
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
184664 E/A-Modul 1: LSB-B participant address 6 reports tolerable error in self-test X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
184665 E/A-Modul 1: LSB-B participant address 6 reports intolerable error in self-test X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
184666 E/A-Modul 1: LSB-B participant address 6 with software version, that is no longer compatible X613:4/6 U-46.3/46.2 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
184667 E/A-Modul 1: LSB-B participant address 6 supports no download function X613:4/6 U-46.3/46.2 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
187252 E/A-Modul 1: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X613:4/6 U-46.3/46.2 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor
187255 E/A-Modul 1: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X613:4/6 U-46.3/46.2 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
187256 E/A-Modul 1: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X613:4/6 U-46.3/46.2 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
187257 E/A-Modul 1: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X613:4/6 U-46.3/46.2 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part
187258 E/A-Modul 1: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X613:4/6 U-46.3/46.2 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors
187259 E/A-Modul 1: Control data transfer LSB-B recognised communication breakdown in bus X613:4/6 U-46.3/46.2 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network
002389508 87
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
187260 E/A-Modul 1: Control data transfer LSB-B driver error: no order to carry out X613:4/6 U-46.3/46.2 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software
187261 E/A-Modul 1: Control data transfer LSB-B driver error: undefined message appears X613:4/6 U-46.3/46.2 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination
187262 E/A-Modul 1: Control data transfer LSB-B driver error: initialising error X613:4/6 U-46.3/46.2 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination
187530 E/A-Modul 1: CAN-participant engine Data transfer subscriber transfer cycle exceeded X615:5/6 U-51.1/51.2 E 0
CAN-Information from participant has exceeded the defined cycle time
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul
187531 E/A-Modul 1: CAN-participant engine Data transfer faulty/missing, max. cycle time exceeded X615:5/6 U-51.1/51.2 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
187630 E/A-Modul 1: CAN-participant gear Data transfer subscriber transfer cycle exceeded X615:5/6 U-51.1/51.2 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
187631 E/A-Modul 1: CAN-participant gear Data transfer faulty/missing, max. cycle time exceeded X615:5/6 U-51.1/51.2 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
187730 E/A-Modul 1: CAN-participant ABV (ABS/ASR) Data transfer subscriber transfer cycle exceeded X615:5/6 U-51.1/51.2 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
187731 E/A-Modul 1: CAN-participant ABV (ABS/ASR) Data transfer faulty/missing, max. cycle time exceeded X615:5/6 U-51.1/51.2 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
188530 E/A-Modul 1: CAN-participant E/A-Modul 1 Data transfer subscriber transfer cycle exceeded X615:5/6 U-51.1/51.2 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
002389508 88
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
188531 E/A-Modul 1: CAN-participant E/A-Modul 1 Data transfer faulty/missing, max. cycle time exceeded X615:5/6 U-51.1/51.2 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
188930 E/A-Modul 1: CAN-participant E/A-Modul 5 Data transfer subscriber transfer cycle exceeded X615:5/6 U-51.1/51.2 E 1
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
188931 E/A-Modul 1: CAN-participant E/A-Modul 5 Data transfer faulty/missing, max. cycle time exceeded X615:5/6 U-51.1/51.2 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
189900 E/A-Modul 1: Control data transfer CAN internal error: register error CAN-controller X615:5/6 U-51.1/51.2 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul
189901 E/A-Modul 1: Control data transfer CAN internal error: RAM-error CAN-controller X615:5/6 U-51.1/51.2 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul
189902 E/A-Modul 1: Control data transfer CAN configuration error CAN-software X615:5/6 U-51.1/51.2 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul, check Software (test system ZE)
189903 E/A-Modul 1: Control data transfer CAN Transfer interrupted after continuous error X615:5/6 U-51.1/51.2 E 1
CAN-Transmission will be aborted
check bus lines/neutral point, replace neutral point or E/A-Modul
189910 E/A-Modul 1: Control data transfer CAN short-term error in bus connection X615:5/6 U-51.1/51.2 E 0
re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated
189911 E/A-Modul 1: Control data transfer CAN permanent error bus connection X615:5/6 U-51.1/51.2 E 1
cyclic re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated
189920 E/A-Modul 1: Control data transfer CAN active participant not responding X615:5/6 U-51.1/51.2 E 0
parameterised substitute values for receiver signals will be used
check error report for missing participant(s), test system ZE
002389508 89
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
189921 E/A-Modul 1: Control data transfer CAN No active subscriber responding X615:5/6 U-51.1/51.2 E 1
parameterised substitute values for receiver signals will be used
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul
189950 E/A-Modul 1: Control data transfer CAN erroneous command test system X615:5/6 U-51.1/51.2 E 1
no reaction to unknown test system control command in CAN-System Software
check Software (test system)
192001 E/A-Modul 1: control engine long-term disruption E/A-Modul <-> engine control E 1
engine control and E/A-Modul at emergency speed
engine control and E/A-Modul, check CAN-bus-connections
192110 E/A-Modul 1: control transmission long-term disruption shift selector operation unit <-> gears E 1
transmission control and E/A-Modul (operation unit) in emergency drive program
check transmission control and E/A-Modul, CAN-bus-connection
192111 E/A-Modul 1: control transmission long-term disruption shift selector crane op. cab<-> E/A-Modul E 1
after re-generation of the connection first "N" requirement
check LSB-connection ZE<>E/A-Modul, crane operators cab travel switch or connection to ZE (test system)
192112 E/A-Modul 1: control transmission long-term disruption connection E/A-Modul <-> operation unit E 1
transmission control and E/A-Modul (operation unit) in emergency drive program
check connection E/A-Modul<>operation unit, power supplies operation unit; replace E/A- Modul or operation unit
192113 E/A-Modul 1: control transmission error in shift selector keys operation unit: key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit
192114 E/A-Modul 1: control transmission shift selector operation unit: D key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit
192115 E/A-Modul 1: control transmission shift selector operation unit: N key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit
192116 E/A-Modul 1: control transmission shift selector operation unit: R key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit
002389508 90
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
192117 E/A-Modul 1: control transmission shift selector operation unit: gear+ key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit
192118 E/A-Modul 1: control transmission shift selector operation unit: gear- key sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit
192119 E/A-Modul 1: control transmission shift selector operation unit: travel program key 1/2 sticking E 1
control system prevents engagement of a gear, check results exclusively after shifting on ignition
in case key is activated release (error will be reset), check key or operation unit
192128 E/A-Modul 1: control transmission feedback of off-road gear simultaneously ON and OFF E 1
control system prevents disengagement of the off-road gear ON or OFF, remaining in actual position when ignition ON
check sensor for acknowledgement(s), check line connections to the E/A-Modul, replace E/A-Modul
002389508 91
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
194800 E/A-Modul 1: control diagnosis system error in diagnosis requirement CAN-participant engine E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants
194801 E/A-Modul 1: control diagnosis system error in diagnosis requirement CAN-participant gears E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants
194802 E/A-Modul 1: control diagnosis system error in diagnosis requirement CAN-participant ABS E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants
194810 E/A-Modul 1: control diagnosis system error in test system-diagnosis CAN-participant engine E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants
194811 E/A-Modul 1: control diagnosis system error in test system-diagnosis CAN-participant gears E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants
194812 E/A-Modul 1: control diagnosis system error in test system-diagnosis CAN-participant ABS E 0
ISO-Diagnosis-inquiry will be interrupted and if necessary carried out again
check CAN-network, check CAN-paticipants
195151 E/A-Modul 1: operation transmission CAN-connection shift selector <-> gear electronics malfunctioning B
195152 E/A-Modul 1: operation transmission connection shift selector <-> keyboard unit malfunctioning B
002389508 92
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
195153 E/A-Modul 1: operation transmission pre-selection not neutral/crane op. cab malfunction <-> E/A-Modul B
195154 E/A-Modul 1: operation transmission shift selector out of order: upper-carriage-operation mode B
195161 E/A-Modul 1: operation transmission shift selector out of order: key sticking B
195172 E/A-Modul 1: operation transmission selection of travel direction prevented, op. type not recognized B
195173 E/A-Modul 1: operation transmission selection of travel dir. prevented, multi-shift selector keys activ. B
195174 E/A-Modul 1: operation transmission shift selector out of order when engine OFF B
195175 E/A-Modul 1: operation transmission selection of travel dir. prevented, pre-selection in neutral only B
195176 E/A-Modul 1: operation transmission selection of travel direction prevented, operation brake not active B
195179 E/A-Modul 1: operation transmission pre-selection gear+ prevented, maximum gear attained B
195180 E/A-Modul 1: operation transmission pre-selection gear+ prevented, rear axle not locked B
002389508 93
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
195183 E/A-Modul 1: operation transmission pre-selection gear- prevented, minimum gear attained B
195190 E/A-Modul 1: operation transmission travel program change-over only possible in neutral B
195194 E/A-Modul 1: operation transmission selection of travel dir. prevented due to gear malf. "do not shift" B
195195 E/A-Modul 1: operation transmission pre-selection not neutral after gear malfunction "do not shift" B
195501 E/A-Modul 1: operation axle suspension operation of 2-hand-function without activation of 2-hand-key B
function is not carried out
activate both keys simultaneously or start test program of keyboard unit
195503 E/A-Modul 1: operation axle suspension operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)
195505 E/A-Modul 1: operation axle suspension operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode
195570 E/A-Modul 1: operation axle suspension undefined condition: neither blocked nor with suspension B
function is not carried out
check blocked limit switch and buffered limit switch
002389508 94
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
195571 E/A-Modul 1: operation axle suspension undefined condition: blocked and with suspension B
function is not carried out
check blocked limit switch and buffered limit switch
195603 E/A-Modul 1: operation level/filling/draining operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)
195605 E/A-Modul 1: operation level/filling/draining operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode
195642 E/A-Modul 1: operation level/filling/draining no individual operation when level function is active B
function is not carried out
only activate level key
195801 E/A-Modul 1: operation axle oscillitation operation of 2-hand-function without activation of 2-hand-key B
function is not carried out
activate both keys simultaneously or start test program of keyboard unit
002389508 95
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
195802 E/A-Modul 1: operation axle oscillitation operation from upper-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)
195803 E/A-Modul 1: operation axle oscillitation operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)
195804 E/A-Modul 1: operation axle oscillitation operation from upper-carriage with under-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode
195805 E/A-Modul 1: operation axle oscillitation operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode
195821 E/A-Modul 1: operation axle oscillitation function not available in upper-carriage operation mode B
function is not carried out
on customers request
195822 E/A-Modul 1: operation axle oscillitation function not available in under-carriage operation mode B
function is not carried out
on customers request
195855 E/A-Modul 1: operation axle oscillitation selection from upper-carriage with axle not blocked B
function is not carried out
block axles
195856 E/A-Modul 1: operation axle oscillitation selection from under-carriage with axle not blocked B
function is not carried out
block axles
002389508 96
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
195901 E/A-Modul 1: operation longitudinal lock operation of 2-hand-function without activation of 2-hand-key B
function is not carried out
activate both keys simultaneously or start test program of keyboard unit
195902 E/A-Modul 1: operation longitudinal lock operation from upper-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)
195903 E/A-Modul 1: operation longitudinal lock operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)
195904 E/A-Modul 1: operation longitudinal lock operation from upper-carriage with under-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode
195905 E/A-Modul 1: operation longitudinal lock operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode
195906 E/A-Modul 1: operation longitudinal lock operation from upper-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 4
195907 E/A-Modul 1: operation longitudinal lock operation from under-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 4
002389508 97
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
196001 E/A-Modul 1: operation transversal lock operation of 2-hand-function without activation of 2-hand-key B
function is not carried out
activate both keys simultaneously or start test program of keyboard unit
196002 E/A-Modul 1: operation transversal lock operation from upper-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) on E/A-Modul 4, check LSB-connection (see electric circuit diagram)
196003 E/A-Modul 1: operation transversal lock operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) on E/A-Modul 4, check LSB-connection (see electric circuit diagram)
196004 E/A-Modul 1: operation transversal lock operation from upper-carriage with under-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode
196005 E/A-Modul 1: operation transversal lock operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode
196006 E/A-Modul 1: operation transversal lock operation from upper-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 4
196007 E/A-Modul 1: operation transversal lock operation from under-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 4
002389508 98
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
196052 E/A-Modul 1: operation transversal lock selection of transversal lock ON with no longitudinal lock selected B
function is not carried out
acivate longitudinal locking
196100 E/A-Modul 1: operation unlocking rear axle function simultaneously ON and OFF B
function is not carried out
do not simultaneously activate contrasting function keys
196101 E/A-Modul 1: operation unlocking rear axle operation of 2-hand-function without activation of 2-hand-key B
function is not carried out
activate both keys simultaneously or start test program of keyboard unit
196102 E/A-Modul 1: operation unlocking rear axle operation from upper-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)
196103 E/A-Modul 1: operation unlocking rear axle operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)
196104 E/A-Modul 1: operation unlocking rear axle operation from upper-carriage with under-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode
196105 E/A-Modul 1: operation unlocking rear axle operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode
196106 E/A-Modul 1: operation unlocking rear axle operation from upper-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 4
196107 E/A-Modul 1: operation unlocking rear axle operation from under-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection to E/A-Modul 4
002389508 99
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
196108 E/A-Modul 1: operation unlocking rear axle unauthorised operation from upper-carriage B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)
196109 E/A-Modul 1: operation unlocking rear axle unauthorised operation from under-carriage B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)
196112 E/A-Modul 1: operation unlocking rear axle unauthorised switching off of function B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)
196114 E/A-Modul 1: operation unlocking rear axle activation of function without operation mode B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)
196115 E/A-Modul 1: operation unlocking rear axle gear limit forwards exceeded with under-carriage operation mode B
function is not carried out
engage lower gear
196116 E/A-Modul 1: operation unlocking rear axle gear limit backwards exceeded with under-carriage operation mode B
function is not carried out
engage lower gear
196117 E/A-Modul 1: operation unlocking rear axle gear limit forwards exceeded with upper-carriage operation mode B
function is not carried out
engage lower gear
196118 E/A-Modul 1: operation unlocking rear axle gear limit backwards exceeded with upper-carriage operation mode B
function is not carried out
engage lower gear
002389508 100
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
196119 E/A-Modul 1: operation unlocking rear axle no direction with under-carriage operation mode B
function is not carried out
check CAN-connection and LSB-connection
196120 E/A-Modul 1: operation unlocking rear axle no direction with upper-carriage operation mode B
function is not carried out
check CAN-connection and LSB-connection
196160 E/A-Modul 1: operation unlocking rear axle undefined condition: simultaneously locked and unlocked B
function is not carried out
check unlocking condition, Check locking limit switch and unlocking limit switch
196200 E/A-Modul 1: operation steering rear axle function simultaneously ON and OFF B
function is not carried out
do not simultaneously activate contrasting function keys
196202 E/A-Modul 1: operation steering rear axle operation from upper-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)
196203 E/A-Modul 1: operation steering rear axle operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)
196204 E/A-Modul 1: operation steering rear axle operation from upper-carriage with under-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode
196205 E/A-Modul 1: operation steering rear axle operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode
196208 E/A-Modul 1: operation steering rear axle unauthorised operation from upper-carriage B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)
196209 E/A-Modul 1: operation steering rear axle unauthorised operation from under-carriage B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)
002389508 101
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
196263 E/A-Modul 1: operation steering rear axle no valid lock condition in upper-carriage operation mode B
function is not carried out
check unlocking condition, Check locking limit switch and unlocking limit switch
196264 E/A-Modul 1: operation steering rear axle no valid lock condition in under-carriage operation mode B
function is not carried out
check unlocking condition, Check locking limit switch and unlocking limit switch
196265 E/A-Modul 1: operation steering rear axle unauthorised steering selection in upper-carriage B
function is not carried out
steering only with rear axle unlocked, check LSB-connection
196266 E/A-Modul 1: operation steering rear axle unauthorised steering selection in under-carriage B
function is not carried out
steering only with rear axle unlocked, check LSB-connection
196570 E/A-Modul 1: operation brakes/pneumatics system upper-carriage parking brake only opened after signal CLOSE B
196703 E/A-Modul 1: operation off-road gear operation from under-carriage without operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)
196704 E/A-Modul 1: operation off-road gear operation from upper-carriage with under-carriage operation mode B
function is not carried out
check entries (15UW, 15OW, 15UWOW) to E/A-Modul 2, check LSB-connection (see electric circuit diagram)
196705 E/A-Modul 1: operation off-road gear operation from under-carriage with upper-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode
196706 E/A-Modul 1: operation off-road gear operation from upper-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection in E/A-Modul 2
002389508 102
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
196707 E/A-Modul 1: operation off-road gear operation from under-carriage without initialisation B
function is not carried out
check voltage supply or LSB-connection in E/A-Modul 2
196775 E/A-Modul 1: operation off-road gear off-road gear and transfer box free in upper-carriage operation mode B
function is not carried out
do not disconnect transfer case in off-road gear ON or off-road gear not ON with disconnection of transfer gear
196776 E/A-Modul 1: operation off-road gear off-road gear and transfer box free in under-carriage operation mode B
function is not carried out
do not disconnect transfer case in off-road gear ON or off-road gear not ON with disconnection of transfer gear
196778 E/A-Modul 1: operation off-road gear speed too high for off-road gear B
function is not carried out
reduce speed
196779 E/A-Modul 1: operation off-road gear off-road gear ON and gears not neutral B
function is not carried out
switch transmission to neutral (N)
197030 E/A-Modul 1: operation heating/air.conditioning switching on air-conditioning only possible with engine running B
function is not carried out
start engine and repeat operation
197182 E/A-Modul 1: operation lighting indicator from upper-carriage in under-carriage operation mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to uppercarriage operation mode
197183 E/A-Modul 1: operation lighting indicator from under-carriage in upper-carriage operation mode B
function is not carried out
switch off undercarriage indicator
197185 E/A-Modul 1: operation lighting hazard lights from upper-carriage and under-carriage B
function is not carried out
switch off warning light
002389508 103
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
197186 E/A-Modul 1: operation lighting rear fog lamp only with light B
function is not carried out
switch on full beam, dipped light or fog light
199890 E/A-Modul 1: operation diagnosis system test program not executable as engine is not OFF B
function prevented
199892 E/A-Modul 1: operation diagnosis system test program not executable as not in under-carriage op. mode B
function prevented
199895 E/A-Modul 1: operation diagnosis system start not possible as gears not in neutral B
function prevented
199896 E/A-Modul 1: operation diagnosis system function prevented/interrupted as parking brake is not locked B
carrying out of AEB-function only possible with closed parking brake
close parking brake, re-start function, then ignition off/on
199922 E/A-Modul 1: operation optional device function not available in under-carriage operation mode B
function is not carried out
on customers request
199924 E/A-Modul 1: operation optional device no customized function in under-carriage operation mode B
function is not carried out
on customers request
200001 ZE 2: system error OS-HC11 (observe parameters) initialising error processor-register erroneous E 2
no crane operation possible
with regular occurrence --> replace ZE
002389508 104
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
200002 ZE 2: system error OS-HC11 (observe parameters) initialising error test total in EPROM/FLASH erroneous E 2
no crane operation possible
check program memory card or ZE
200006 ZE 2: system error OS-HC11 (observe parameters) initialising error RAM erroneous E 2
no crane operation possible
with regular occurrence --> replace ZE
200013 ZE 2: system error OS-HC11 (observe parameters) test total in EPROM/FLASH erroneous E 2
entry in error memory, all crane movements will be stopped
check program memory card
002389508 105
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
200017 ZE 2: system error OS-HC11 (observe parameters) total of CPU-time distribution too great E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
200018 ZE 2: system error OS-HC11 (observe parameters) arithmetic overflow (16 Bit) E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
200019 ZE 2: system error OS-HC11 (observe parameters) division through zero (16 Bit) E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
200023 ZE 2: system error OS-HC11 (observe parameters) program incapable of running (type identification) E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
002389508 106
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
200044 ZE 2: system error OS-HC11 (observe parameters) output parameter without effect, from inactive output E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
200045 ZE 2: system error OS-HC11 (observe parameters) entry parameter undefined, from inactive input E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
200047 ZE 2: system error OS-HC11 (observe parameters) realtime-control block not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
200049 ZE 2: system error OS-HC11 (observe parameters) urgent modul, ZE not available E 2
entry in error memory, no crane operation possible
check ZE
002389508 107
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
200052 ZE 2: system error OS-HC11 (observe parameters) file not open on close E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
200053 ZE 2: system error OS-HC11 (observe parameters) system mask not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
200054 ZE 2: system error OS-HC11 (observe parameters) system text not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
200057 ZE 2: system error OS-HC11 (observe parameters) default load chart missing E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> notify after-sales service
200058 ZE 2: system error OS-HC11 (observe parameters) amplifier erroneous or return power feed E 2
entry in error memory, all crane movements will be stopped
check wiring
002389508 108
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
200066 ZE 2: system error OS-HC11 (observe parameters) ADC working outside the permissible tolerance E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE
200067 ZE 2: system error OS-HC11 (observe parameters) arithmetic processor not available E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE
002389508 109
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
200074 ZE 2: system error OS-HC11 (observe parameters) transformation ASCII to BIN erroneous E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE
200076 ZE 2: system error OS-HC11 (observe parameters) incorrectly inserted power unit E 2
entry in error memory, all crane movements will be stopped
check memory card in power supply unit
200080 ZE 2: system error OS-HC11 (observe parameters) fatal internal software error E 2
entry in error memory, all crane movements will be stopped
with regular occurrence --> replace ZE
200094 ZE 2: system error OS-HC11 (observe parameters) transmission error parallel bus E 2
entry in error memory, all crane movements will be stopped
check ZE, bus circuit board, power supply unit
002389508 110
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
202002 ZE 2: system error OS-TMS initialising error test total in EPROM/FLASH erroneous E 2
entry of error in error memory, all crane movements will be stopped
replace ZE
210060 ZE 2: output 0 safety chain error, diode defect or safety contact sticking X72:16 O-64.2 E 1
report of error, otherwise no reaction
checking of safety contact and diode
002389508 111
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
210073 ZE 2: output 0 open circuit or short circuit to supply voltage/ground X72:16 O-64.2 E 1
entry in error list
re-start, check lines
210160 ZE 2: output 1 safety chain error, diode defect or safety contact sticking X72:17 O-64.3 E 1
report of error, otherwise no reaction
checking of safety contact and diode
210173 ZE 2: output 1 open circuit or short circuit to supply voltage/ground X72:17 O-64.3 E 1
entry in error list
re-start, check lines
210260 ZE 2: output 2 safety chain error, diode defect or safety contact sticking X72:18 E 1
report of error, otherwise no reaction
checking of safety contact and diode
002389508 112
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
210360 ZE 2: output 3 safety chain error, diode defect or safety contact sticking X72:19 E 1
report of error, otherwise no reaction
checking of safety contact and diode
210460 ZE 2: output 4 safety chain error, diode defect or safety contact sticking X72:20 O-67.2 E 1
report of error, otherwise no reaction
checking of safety contact and diode
002389508 113
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
210473 ZE 2: output 4 open circuit or short circuit to supply voltage/ground X72:20 O-67.2 E 1
entry in error list
re-start, check lines
210560 ZE 2: output 5 safety chain error, diode defect or safety contact sticking X72:21 O-67.4 E 1
report of error, otherwise no reaction
checking of safety contact and diode
210573 ZE 2: output 5 open circuit or short circuit to supply voltage/ground X72:21 O-67.4 E 1
entry in error list
re-start, check lines
002389508 114
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
210673 ZE 2: output 6 open circuit or short circuit to supply voltage/ground X72:22 O-72.3 E 1
entry in error list
re-start, check lines
210773 ZE 2: output 7 open circuit or short circuit to supply voltage/ground X72:23 O-72.5 E 1
entry in error list
re-start, check lines
002389508 115
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
220050 ZE 2: LSB participant address 0 reports an incorrect sensor type X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
220051 ZE 2: LSB participant address 0 was not configured for the block transfer X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
220053 ZE 2: LSB participant address 0 no longer reports or withdrawn during running period X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
220054 ZE 2: LSB participant address 0 Features other settings (parameters) as pre-entered set values X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
220064 ZE 2: LSB participant address 0 reports tolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
220065 ZE 2: LSB participant address 0 reports intolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
220066 ZE 2: LSB participant address 0 with software version, that is no longer compatible X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
002389508 116
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
220150 ZE 2: LSB participant address 1 reports an incorrect sensor type X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
220151 ZE 2: LSB participant address 1 was not configured for the block transfer X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
220153 ZE 2: LSB participant address 1 no longer reports or withdrawn during running period X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
220154 ZE 2: LSB participant address 1 Features other settings (parameters) as pre-entered set values X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
220164 ZE 2: LSB participant address 1 reports tolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
220165 ZE 2: LSB participant address 1 reports intolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
220166 ZE 2: LSB participant address 1 with software version, that is no longer compatible X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
222350 ZE 2: LSB participant address 23 reports an incorrect sensor type X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
222351 ZE 2: LSB participant address 23 was not configured for the block transfer X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
002389508 117
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
222353 ZE 2: LSB participant address 23 no longer reports or withdrawn during running period X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
222354 ZE 2: LSB participant address 23 Features other settings (parameters) as pre-entered set values X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
222363 ZE 2: LSB participant address 23 not available or open line X635B:z14/z16 O-54.4/54.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
222364 ZE 2: LSB participant address 23 reports tolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
222365 ZE 2: LSB participant address 23 reports intolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
222366 ZE 2: LSB participant address 23 with software version, that is no longer compatible X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
222450 ZE 2: LSB participant address 24 reports an incorrect sensor type X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
222451 ZE 2: LSB participant address 24 was not configured for the block transfer X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
222453 ZE 2: LSB participant address 24 no longer reports or withdrawn during running period X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
002389508 118
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
222454 ZE 2: LSB participant address 24 Features other settings (parameters) as pre-entered set values X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
222463 ZE 2: LSB participant address 24 not available or open line X635B:z14/z16 O-54.4/54.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
222464 ZE 2: LSB participant address 24 reports tolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
222465 ZE 2: LSB participant address 24 reports intolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
222466 ZE 2: LSB participant address 24 with software version, that is no longer compatible X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
222650 ZE 2: LSB participant address 26 reports an incorrect sensor type X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
222651 ZE 2: LSB participant address 26 was not configured for the block transfer X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
222653 ZE 2: LSB participant address 26 no longer reports or withdrawn during running period X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
222654 ZE 2: LSB participant address 26 Features other settings (parameters) as pre-entered set values X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
002389508 119
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
222663 ZE 2: LSB participant address 26 not available or open line X635B:z14/z16 O-54.4/54.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
222664 ZE 2: LSB participant address 26 reports tolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
222665 ZE 2: LSB participant address 26 reports intolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
222666 ZE 2: LSB participant address 26 with software version, that is no longer compatible X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
222750 ZE 2: LSB participant address 27 reports an incorrect sensor type X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
222751 ZE 2: LSB participant address 27 was not configured for the block transfer X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
222753 ZE 2: LSB participant address 27 no longer reports or withdrawn during running period X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
222754 ZE 2: LSB participant address 27 Features other settings (parameters) as pre-entered set values X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
222763 ZE 2: LSB participant address 27 not available or open line X635B:z14/z16 O-54.4/54.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
002389508 120
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
222764 ZE 2: LSB participant address 27 reports tolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
222765 ZE 2: LSB participant address 27 reports intolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
222766 ZE 2: LSB participant address 27 with software version, that is no longer compatible X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
222850 ZE 2: LSB participant address 28 reports an incorrect sensor type X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
222851 ZE 2: LSB participant address 28 was not configured for the block transfer X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
222853 ZE 2: LSB participant address 28 no longer reports or withdrawn during running period X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
222854 ZE 2: LSB participant address 28 Features other settings (parameters) as pre-entered set values X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
222863 ZE 2: LSB participant address 28 not available or open line X635B:z14/z16 O-54.4/54.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
222864 ZE 2: LSB participant address 28 reports tolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
002389508 121
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
222865 ZE 2: LSB participant address 28 reports intolerable error in self-test X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
222866 ZE 2: LSB participant address 28 with software version, that is no longer compatible X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
223206 ZE 2: Control data transfer LSB line connection to participant disrupted/not plugged in X635B:z14/z16 O-54.4/54.4 E 1
report of error, participant will be deactivated, data buffer to the application will be set to 0
check bus connections, if connections OK despite error then check sensor and replace if necessary
223252 ZE 2: Control data transfer LSB has recognised Bus collisions, communication interrupted X635B:z14/z16 O-54.4/54.4 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor
223255 ZE 2: Control data transfer LSB Bus connection faulty/defect, short circuit to supply voltage X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
223256 ZE 2: Control data transfer LSB Bus connection faulty/defect, no supply/short circuit to earth X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
223257 ZE 2: Control data transfer LSB has recognised network re-set (data transfer starts again) X635B:z14/z16 O-54.4/54.4 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part
223258 ZE 2: Control data transfer LSB recognised participant with incorrect baud rate in bus X635B:z14/z16 O-54.4/54.4 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors
223259 ZE 2: Control data transfer LSB recognised communication breakdown in bus X635B:z14/z16 O-54.4/54.4 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network
002389508 122
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
223260 ZE 2: Control data transfer LSB driver error: no order to carry out X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software
223261 ZE 2: Control data transfer LSB driver error: undefined message appears X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination
223262 ZE 2: Control data transfer LSB driver error: initialising error X635B:z14/z16 O-54.4/54.4 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination
226002 ZE 2: input 12 sensor deficiency data short circuit to supply voltage X635B:d26 E 1
report of error, otherwise no reaction
check supply, LICCON input, sensor lines to short or break, sensor
230500 ZE 2: remote control transmit, maximum transmission cycle radio contact exceeded E 1
radio control deactivated
check radio receiver/-transmitter (battery!)
002389508 123
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
233933 ZE 2: crane control Signal press. tran. "P" lower lim value fallen short of (no press.! E 1
Diagnosis and output of error with "Control on without engine"
check supply, LICCON input, sensor lines to short or break, sensor
233934 ZE 2: crane control Signal pressure transducer "P" lower limit value exceeded (no press.!) E 1
Diagnosis and output of error with "Control on without engine"
check supply, LICCON input, sensor lines to short or break, sensor
233935 ZE 2: crane control Signal press. tran. "LS" lower lim value fallen short of (no press.!) E 1
Diagnosis and output of error with "Control on without engine"
check supply, LICCON input, sensor lines to short or break, sensor
233936 ZE 2: crane control Signal press. tran. "LS" lower limit value exceeded (no pressure!) E 1
Diagnosis and output of error with "Control on without engine"
check supply, LICCON input, sensor lines to short or break, sensor
233937 ZE 2: crane control Press. tran. "P" and "LS" outside permiss. signal diff (no press. E 1
Diagnosis and output of error with "Control on without engine"
Replace pressure transducer "P" and/or "LS"
233938 ZE 2: crane control Signal pressure transducer "P" greater "LS" (no pressure!) E 1
Diagnosis and output of error with "Control on without engine"
Swap pressure transducer "P" and "LS" with each other (mount P-sensor in LS position)
002389508 124
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
234200 ZE 2: instruments armrest right master switch 1Y both dir. contacts standing by simultaneously E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board
234201 ZE 2: instruments armrest right master switch 1X both dir. contacts standing by simultaneously E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board
234202 ZE 2: instruments armrest right master switch 1Y directional contact without zero contact E 1
output of error, shut-down through application
check supply, LICCON input, sensor lines for breaks , check defect sensor
234203 ZE 2: instruments armrest right master switch 1X directional contact without zero contact E 1
output of error, shut-down through application
check supply, LICCON input, sensor lines for breaks , check defect sensor
234204 ZE 2: instruments armrest right master switch 1Y analogue signal short to supply voltage E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board
234205 ZE 2: instruments armrest right master switch 1X analogue signal short to supply voltage E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board
234208 ZE 2: instruments armrest right master switch 1Y analogue sig. open circuit or short circ. to ground E 1
output of error, shut-down through application
check supply, LICCON input, sensor line for breaks , defect sensor through withdrawing of sensor
234209 ZE 2: instruments armrest right master switch 1X analogue sig. open circuit or short circ. to ground E 1
output of error, shut-down through application
check supply, LICCON input, sensor line for breaks , defect sensor through withdrawing of sensor
234312 ZE 2: instruments armrest left master switch 2Y both dir. contacts standing by simultaneously E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board
234314 ZE 2: instruments armrest left master switch 2Y directional contact without zero contact E 1
output of error, shut-down through application
check supply, LICCON input, sensor lines for breaks , check defect sensor
002389508 125
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
234316 ZE 2: instruments armrest left master switch 2Y analogue signal short to supply voltage E 1
output of error, shut-down through application
check sensor lines for shorts, defect sensor through unplugging of sensor, connection to circuit board
234320 ZE 2: instruments armrest left master switch 2Y analogue sig. open circuit or short to ground E 1
output of error, shut-down through application
check supply, LICCON input, sensor line for breaks , defect sensor through withdrawing of sensor
002389508 126
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
234824 ZE 2: control diagnosis system Charge press. hoist gear or press. switch'Lower freely'faulty/not pre E 1
Carrying out of test program delayed / interrupted
Check charge pressure, carry out test program again
234830 ZE 2: control diagnosis system Pressure cut-off pump outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure reduction and pressure limitation LS, carry out test program again
234831 ZE 2: control diagnosis system Pressure cut-off hoist gear lift outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure hoist gear, carry out test program again
234832 ZE 2: control diagnosis system Pressure cut-off hoist gear lower outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check pressure hoist gear, carry out test program again
234846 ZE 2: control diagnosis system Initial current winch lift above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
234847 ZE 2: control diagnosis system Initial current winch lift below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
234848 ZE 2: control diagnosis system Initial current winch lower above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
002389508 127
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
234849 ZE 2: control diagnosis system Initial current winch lower below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
234867 ZE 2: control diagnosis system Initial current luffing up above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
234868 ZE 2: control diagnosis system Initial current luffing up below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
234869 ZE 2: control diagnosis system Initial current luffing down above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
002389508 128
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
234870 ZE 2: control diagnosis system Initial current luffing down below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
234873 ZE 2: control diagnosis system luffing speed luffing down too low E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
234874 ZE 2: control diagnosis system luffing speed luffing down too high E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
234888 ZE 2: control diagnosis system Initial current pump 1 above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
234889 ZE 2: control diagnosis system Initial current pump 1 below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
234892 ZE 2: control diagnosis system Pump 1 final current or flow-rate below permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
002389508 129
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
234893 ZE 2: control diagnosis system Pump 1 final current or flow-rate above permissible area E 1
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
234898 ZE 2: control diagnosis system Readjustment of hoist gear lift outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check controller / gate valve / pressure balance / pump(s)
234899 ZE 2: control diagnosis system Readjustment hoist gear lower outside of permissible area E 1
Carrying out of test program delayed / interrupted
Check controller / gate valve / pressure balance / pump(s)
002389508 130
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
002389508 131
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
002389508 132
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
235708 ZE 2: operation luffing luffing up of main boom shut-down working area limitation ABB B
operational shut down
luff main boom down until crane is in working area again - shunting through shut-down of working area limitation
235709 ZE 2: operation luffing luffing down of main boom shut-down working area limitation ABB B
operational shut down
luff main boom up until crane in working area again - shunting through shut-down of working area limitation
002389508 133
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
235747 ZE 2: operation luffing Warning luffing up, dropping of load with reduction of reach B
235748 ZE 2: operation luffing Shut-down luffing up, dropping of load with reduction of reach B
002389508 134
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
236100 ZE 2: Operation ballasting / counterweight carriage Counterweight UP selected, final position not started B 1
report of error, otherwise no reaction
Approach end position, if ok check: -supply, -input LICCON, -sensor line for short-circuit or interruption, -
236101 ZE 2: Operation ballasting / counterweight carriage Counterweight DOWN selected, final position not started B 1
report of error, otherwise no reaction
Approach end position, if ok check: -supply, -input LICCON, -sensor line for short-circuit or interruption, -
237049 ZE 2: operation instruments crane operators cab seat contact not activated, crane movements blocked B 1
output of error, shut-down through application
sit down (seat limit switch) or dead man (in master switch) or check LICCON input, sensor lines, sensor
237200 ZE 2: operation instruments armrest right master switch 1Y not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor
237201 ZE 2: operation instruments armrest right master switch 1X not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor
237312 ZE 2: operation instruments armrest left master switch 2Y not in neutral when starting B 1
output of error, shut-down through application
release master switch briefly or check LICCON input, gear lines, sensor
239800 ZE 2: operation diagnosis system interruption, master switch defective or incorrectly deflected B 1
Carrying out of test program delayed / interrupted
Note direction of movements, carry out test program again
002389508 135
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
239804 ZE 2: operation diagnosis system Termination, change-over luff/telescoping incorrect switch position B
Carrying out of test program delayed / interrupted
Check valve / pump / pressure
239812 ZE 2: operation diagnosis system Termination, windable rope length too short B 1
Carrying out of test program delayed / interrupted
Check reeving wind off more rope, carry out test program again
239813 ZE 2: operation diagnosis system Termination, maximum speed < 100% (C-key) B 1
Carrying out of test program delayed / interrupted
Adjust speed C key to 100%, carry out test program again
239814 ZE 2: operation diagnosis system Alignment aid not correctly shut down B 1
Invalid operation condition, no proper crane operation possible
Apply F key, end active test program
239820 ZE 2: operation diagnosis system interruption, boom angle beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct luffing position, carry out test program again
239821 ZE 2: operation diagnosis system interruption, tele length beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Extend to correct telescopic boom length length, carry out test program again
239822 ZE 2: operation diagnosis system interruption, hook load beyond the prescribed range B 1
Carrying out of test program delayed / interrupted
Note max. hook load, carry out test program again
002389508 136
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
239830 ZE 2: operation diagnosis system Termination, op. temperature hydraulic oil below permissible area B 1
Carrying out of test program delayed / interrupted
Operate engine and hydraulics to operating temperature, erase error, actuate Reset and start again
239831 ZE 2: operation diagnosis system Termination, op. temperature hydraulic oil above permissible area B 1
Test program is interrupted, set value not needed
Allow hydr to cool, if nec. operate tele. boom length (cool via oil change),erase err, actuate Reset and restart
261002 E/A-Modul 2: system error OS-C167 initialising error test total in EPROM/FLASH erroneous E 2
error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul
002389508 137
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
272052 E/A-Modul 2: input/output DEA0 output open, to low load, short circuit to supply voltage X623:17 U-69.6 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
272053 E/A-Modul 2: input/output DEA0 transistor current supply insufficient or missing X623:17 U-69.6 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
272054 E/A-Modul 2: input/output DEA0 short circuit to supply voltage X623:17 U-69.6 E 1
error report on display
check output for short, if necessary replace E/A-Modul
272055 E/A-Modul 2: input/output DEA0 excessive temperature, short circuit to ground or overload X623:17 U-69.6 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
272152 E/A-Modul 2: input/output DEA1 output open, to low load, short circuit to supply voltage X623:15 U-60.2 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
272153 E/A-Modul 2: input/output DEA1 transistor current supply insufficient or missing X623:15 U-60.2 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
272154 E/A-Modul 2: input/output DEA1 short circuit to supply voltage X623:15 U-60.2 E 1
error report on display
check output for short, if necessary replace E/A-Modul
272155 E/A-Modul 2: input/output DEA1 excessive temperature, short circuit to ground or overload X623:15 U-60.2 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
002389508 138
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
272252 E/A-Modul 2: input/output DEA2 output open, to low load, short circuit to supply voltage X623:13 U-69.5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
272253 E/A-Modul 2: input/output DEA2 transistor current supply insufficient or missing X623:13 U-69.5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
272254 E/A-Modul 2: input/output DEA2 short circuit to supply voltage X623:13 U-69.5 E 1
error report on display
check output for short, if necessary replace E/A-Modul
272255 E/A-Modul 2: input/output DEA2 excessive temperature, short circuit to ground or overload X623:13 U-69.5 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
272352 E/A-Modul 2: input/output DEA3 output open, to low load, short circuit to supply voltage X623:11 U-71.2 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
272353 E/A-Modul 2: input/output DEA3 transistor current supply insufficient or missing X623:11 U-71.2 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
272354 E/A-Modul 2: input/output DEA3 short circuit to supply voltage X623:11 U-71.2 E 1
error report on display
check output for short, if necessary replace E/A-Modul
272355 E/A-Modul 2: input/output DEA3 excessive temperature, short circuit to ground or overload X623:11 U-71.2 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
272452 E/A-Modul 2: input/output DEA4 output open, to low load, short circuit to supply voltage X623:9 U-71.3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
272453 E/A-Modul 2: input/output DEA4 transistor current supply insufficient or missing X623:9 U-71.3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
002389508 139
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
272454 E/A-Modul 2: input/output DEA4 short circuit to supply voltage X623:9 U-71.3 E 1
error report on display
check output for short, if necessary replace E/A-Modul
272455 E/A-Modul 2: input/output DEA4 excessive temperature, short circuit to ground or overload X623:9 U-71.3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
272552 E/A-Modul 2: input/output DEA5 output open, to low load, short circuit to supply voltage X623:7 U-70.3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
272553 E/A-Modul 2: input/output DEA5 transistor current supply insufficient or missing X623:7 U-70.3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
272554 E/A-Modul 2: input/output DEA5 short circuit to supply voltage X623:7 U-70.3 E 1
error report on display
check output for short, if necessary replace E/A-Modul
272555 E/A-Modul 2: input/output DEA5 excessive temperature, short circuit to ground or overload X623:7 U-70.3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
272652 E/A-Modul 2: input/output DEA6 output open, to low load, short circuit to supply voltage X623:5 U-70.1 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
272653 E/A-Modul 2: input/output DEA6 transistor current supply insufficient or missing X623:5 U-70.1 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
272654 E/A-Modul 2: input/output DEA6 short circuit to supply voltage X623:5 U-70.1 E 1
error report on display
check output for short, if necessary replace E/A-Modul
272655 E/A-Modul 2: input/output DEA6 excessive temperature, short circuit to ground or overload X623:5 U-70.1 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
002389508 140
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
272752 E/A-Modul 2: input/output DEA7 output open, to low load, short circuit to supply voltage X623:3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
272753 E/A-Modul 2: input/output DEA7 transistor current supply insufficient or missing X623:3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
272755 E/A-Modul 2: input/output DEA7 excessive temperature, short circuit to ground or overload X623:3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
273481 E/A-Modul 2: voltage input E4 short circuit to supply voltage, open line X622:9 U-66.3 E 1
symbol for compressed air supply 1 is flashing on the display unit
check input signal on the E/A-Modul or sensor
273581 E/A-Modul 2: voltage input E5 short circuit to supply voltage, open line X622:7 U-66.5 E 1
symbol for compressed air supply 2 is flashing on the display unit
check input signal on the E/A-Modul or sensor
273681 E/A-Modul 2: voltage input E6 short circuit to supply voltage, open line X622:5 U-66.7 E 1
symbol for compressed air supply 3 is flashing on the display unit
check input signal on the E/A-Modul or sensor
273782 E/A-Modul 2: voltage input E7 short circuit to ground, open line, constant current 10 mA incorrect X622:4 U-53.8 E 1
no reaction
check input signal on the E/A-Modul or sensor
273783 E/A-Modul 2: voltage input E7 short circuit to supply voltage, open line, lack of voltage X622:4 U-53.8 E 1
no reaction
check input signal on the E/A-Modul or sensor
279052 E/A-Modul 2: output A0 output open, to low load, short circuit to supply voltage X623:18 U-60.1 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
002389508 141
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
279053 E/A-Modul 2: output A0 transistor current supply insufficient or missing X623:18 U-60.1 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
279055 E/A-Modul 2: output A0 excessive temperature, short circuit to ground or overload X623:18 U-60.1 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
279152 E/A-Modul 2: output A1 output open, to low load, short circuit to supply voltage X623:16 U-60.3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
279153 E/A-Modul 2: output A1 transistor current supply insufficient or missing X623:16 U-60.3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
279155 E/A-Modul 2: output A1 excessive temperature, short circuit to ground or overload X623:16 U-60.3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
279250 E/A-Modul 2: bridge output A2 short circuit to ground, junction not supplied X623:14 U-61.3 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul
279251 E/A-Modul 2: bridge output A2 short circuit to supply voltage, excessive temperature X623:14 U-61.3 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul
279252 E/A-Modul 2: bridge output A2 output open, to low load, short circuit to supply voltage X623:14 U-61.3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
002389508 142
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
279253 E/A-Modul 2: bridge output A2 transistor current supply insufficient or missing X623:14 U-61.3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
279254 E/A-Modul 2: bridge output A2 short circuit to supply voltage X623:14 U-61.3 E 1
error report on display
check output for short, if necessary replace E/A-Modul
279255 E/A-Modul 2: bridge output A2 excessive temperature, short circuit to ground or overload X623:14 U-61.3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
279350 E/A-Modul 2: bridge output A3 short circuit to ground, junction not supplied X623:12 U-61.3 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul
279351 E/A-Modul 2: bridge output A3 short circuit to supply voltage, excessive temperature X623:12 U-61.3 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul
279352 E/A-Modul 2: bridge output A3 output open, to low load, short circuit to supply voltage X623:12 U-61.3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
279353 E/A-Modul 2: bridge output A3 transistor current supply insufficient or missing X623:12 U-61.3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
279354 E/A-Modul 2: bridge output A3 short circuit to supply voltage X623:12 U-61.3 E 1
error report on display
check output for short, if necessary replace E/A-Modul
279355 E/A-Modul 2: bridge output A3 excessive temperature, short circuit to ground or overload X623:12 U-61.3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
283301 E/A-Modul 2: SPI-display unit Faulty data transfer E/A-module<>unit (time exceeded) X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
002389508 143
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
283302 E/A-Modul 2: SPI-display unit Serious system error to SPI-connection (interface) X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
283303 E/A-Modul 2: SPI-display unit break in line or short circuit to supply voltage X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary
283304 E/A-Modul 2: SPI-display unit break in line or short circuit to ground X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary
283306 E/A-Modul 2: SPI-display unit Data transfer faulty (faulty check byte) X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
suppress EMV- interference
283307 E/A-Modul 2: SPI-display unit Unit faulty/missing, incorrect unit inserted (ID) X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
check periphery and replace if necessary, check Software version, check EMV- interference
283308 E/A-Modul 2: SPI-display unit Data transfer faulty (incorrect number of data bytes received) X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
283900 E/A-Modul 2: Control operating unit (SPI) Faulty initialisation data connection E/A-module<>unit X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
283902 E/A-Modul 2: Control operating unit (SPI) Serious system error to SPI-connection (interface) X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
283905 E/A-Modul 2: Control operating unit (SPI) Initialisation error, resetting inputs/outputs faulty X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
check wiring, check periphery and replace if necessary, check E/A-Modul and replace if necessary
283907 E/A-Modul 2: Control operating unit (SPI) Unit faulty/missing, incorrect unit inserted (ID) X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
connect functional periphery unit, system then eliminates error independently
002389508 144
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
283908 E/A-Modul 2: Control operating unit (SPI) Data transfer faulty (incorrect number of data bytes received) X624:1/2/3/5/6/ U-48.7/48.6/48.5/48. E 1
error indication on display 7/8 4/48.4/48.3/48.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
284050 E/A-Modul 2: LSB-B participant address 0 reports an incorrect sensor type X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
284051 E/A-Modul 2: LSB-B participant address 0 was not configured for the block transfer X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
284053 E/A-Modul 2: LSB-B participant address 0 no longer reports or withdrawn during running period X623:4/6 U-46.5/46.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
284054 E/A-Modul 2: LSB-B participant address 0 Features other settings (parameters) as pre-entered set values X623:4/6 U-46.5/46.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
284064 E/A-Modul 2: LSB-B participant address 0 reports tolerable error in self-test X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
284065 E/A-Modul 2: LSB-B participant address 0 reports intolerable error in self-test X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
284066 E/A-Modul 2: LSB-B participant address 0 with software version, that is no longer compatible X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
284067 E/A-Modul 2: LSB-B participant address 0 supports no download function X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
284150 E/A-Modul 2: LSB-B participant address 1 reports an incorrect sensor type X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
002389508 145
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
284151 E/A-Modul 2: LSB-B participant address 1 was not configured for the block transfer X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
284153 E/A-Modul 2: LSB-B participant address 1 no longer reports or withdrawn during running period X623:4/6 U-46.5/46.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
284154 E/A-Modul 2: LSB-B participant address 1 Features other settings (parameters) as pre-entered set values X623:4/6 U-46.5/46.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
284164 E/A-Modul 2: LSB-B participant address 1 reports tolerable error in self-test X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
284165 E/A-Modul 2: LSB-B participant address 1 reports intolerable error in self-test X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
284166 E/A-Modul 2: LSB-B participant address 1 with software version, that is no longer compatible X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
284167 E/A-Modul 2: LSB-B participant address 1 supports no download function X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
284250 E/A-Modul 2: LSB-B participant address 2 reports an incorrect sensor type X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
284251 E/A-Modul 2: LSB-B participant address 2 was not configured for the block transfer X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
284253 E/A-Modul 2: LSB-B participant address 2 no longer reports or withdrawn during running period X623:4/6 U-46.5/46.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
002389508 146
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
284254 E/A-Modul 2: LSB-B participant address 2 Features other settings (parameters) as pre-entered set values X623:4/6 U-46.5/46.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
284264 E/A-Modul 2: LSB-B participant address 2 reports tolerable error in self-test X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
284265 E/A-Modul 2: LSB-B participant address 2 reports intolerable error in self-test X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
284266 E/A-Modul 2: LSB-B participant address 2 with software version, that is no longer compatible X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
284267 E/A-Modul 2: LSB-B participant address 2 supports no download function X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
284350 E/A-Modul 2: LSB-B participant address 3 reports an incorrect sensor type X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
284351 E/A-Modul 2: LSB-B participant address 3 was not configured for the block transfer X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
284353 E/A-Modul 2: LSB-B participant address 3 no longer reports or withdrawn during running period X623:4/6 U-46.5/46.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
284354 E/A-Modul 2: LSB-B participant address 3 Features other settings (parameters) as pre-entered set values X623:4/6 U-46.5/46.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
284364 E/A-Modul 2: LSB-B participant address 3 reports tolerable error in self-test X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
002389508 147
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
284365 E/A-Modul 2: LSB-B participant address 3 reports intolerable error in self-test X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
284366 E/A-Modul 2: LSB-B participant address 3 with software version, that is no longer compatible X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
284367 E/A-Modul 2: LSB-B participant address 3 supports no download function X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
284450 E/A-Modul 2: LSB-B participant address 4 reports an incorrect sensor type X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
284451 E/A-Modul 2: LSB-B participant address 4 was not configured for the block transfer X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
284453 E/A-Modul 2: LSB-B participant address 4 no longer reports or withdrawn during running period X623:4/6 U-46.5/46.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
284454 E/A-Modul 2: LSB-B participant address 4 Features other settings (parameters) as pre-entered set values X623:4/6 U-46.5/46.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
284464 E/A-Modul 2: LSB-B participant address 4 reports tolerable error in self-test X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
284465 E/A-Modul 2: LSB-B participant address 4 reports intolerable error in self-test X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
284466 E/A-Modul 2: LSB-B participant address 4 with software version, that is no longer compatible X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
002389508 148
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
284467 E/A-Modul 2: LSB-B participant address 4 supports no download function X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
284550 E/A-Modul 2: LSB-B participant address 5 reports an incorrect sensor type X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
284551 E/A-Modul 2: LSB-B participant address 5 was not configured for the block transfer X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
284553 E/A-Modul 2: LSB-B participant address 5 no longer reports or withdrawn during running period X623:4/6 U-46.5/46.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
284554 E/A-Modul 2: LSB-B participant address 5 Features other settings (parameters) as pre-entered set values X623:4/6 U-46.5/46.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
284564 E/A-Modul 2: LSB-B participant address 5 reports tolerable error in self-test X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
284565 E/A-Modul 2: LSB-B participant address 5 reports intolerable error in self-test X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
284566 E/A-Modul 2: LSB-B participant address 5 with software version, that is no longer compatible X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
284567 E/A-Modul 2: LSB-B participant address 5 supports no download function X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
284650 E/A-Modul 2: LSB-B participant address 6 reports an incorrect sensor type X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
002389508 149
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
284651 E/A-Modul 2: LSB-B participant address 6 was not configured for the block transfer X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
284653 E/A-Modul 2: LSB-B participant address 6 no longer reports or withdrawn during running period X623:4/6 U-46.5/46.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
284654 E/A-Modul 2: LSB-B participant address 6 Features other settings (parameters) as pre-entered set values X623:4/6 U-46.5/46.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
284664 E/A-Modul 2: LSB-B participant address 6 reports tolerable error in self-test X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
284665 E/A-Modul 2: LSB-B participant address 6 reports intolerable error in self-test X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
284666 E/A-Modul 2: LSB-B participant address 6 with software version, that is no longer compatible X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
284667 E/A-Modul 2: LSB-B participant address 6 supports no download function X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
285050 E/A-Modul 2: LSB-B participant address 10 reports an incorrect sensor type X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
285051 E/A-Modul 2: LSB-B participant address 10 was not configured for the block transfer X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
285053 E/A-Modul 2: LSB-B participant address 10 no longer reports or withdrawn during running period X623:4/6 U-46.5/46.4 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
002389508 150
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
285054 E/A-Modul 2: LSB-B participant address 10 Features other settings (parameters) as pre-entered set values X623:4/6 U-46.5/46.4 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
285064 E/A-Modul 2: LSB-B participant address 10 reports tolerable error in self-test X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
285065 E/A-Modul 2: LSB-B participant address 10 reports intolerable error in self-test X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
285066 E/A-Modul 2: LSB-B participant address 10 with software version, that is no longer compatible X623:4/6 U-46.5/46.4 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
285067 E/A-Modul 2: LSB-B participant address 10 supports no download function X623:4/6 U-46.5/46.4 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
287252 E/A-Modul 2: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X623:4/6 U-46.5/46.4 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor
287255 E/A-Modul 2: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X623:4/6 U-46.5/46.4 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
287256 E/A-Modul 2: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X623:4/6 U-46.5/46.4 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
287257 E/A-Modul 2: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X623:4/6 U-46.5/46.4 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part
287258 E/A-Modul 2: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X623:4/6 U-46.5/46.4 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors
002389508 151
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
287259 E/A-Modul 2: Control data transfer LSB-B recognised communication breakdown in bus X623:4/6 U-46.5/46.4 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network
287260 E/A-Modul 2: Control data transfer LSB-B driver error: no order to carry out X623:4/6 U-46.5/46.4 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software
287261 E/A-Modul 2: Control data transfer LSB-B driver error: undefined message appears X623:4/6 U-46.5/46.4 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination
287262 E/A-Modul 2: Control data transfer LSB-B driver error: initialising error X623:4/6 U-46.5/46.4 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination
287530 E/A-Modul 2: CAN-participant engine Data transfer subscriber transfer cycle exceeded X625:5/6 U-51.4/51.4 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
287531 E/A-Modul 2: CAN-participant engine Data transfer faulty/missing, max. cycle time exceeded X625:5/6 U-51.4/51.4 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
287630 E/A-Modul 2: CAN-participant gear Data transfer subscriber transfer cycle exceeded X625:5/6 U-51.4/51.4 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
287631 E/A-Modul 2: CAN-participant gear Data transfer faulty/missing, max. cycle time exceeded X625:5/6 U-51.4/51.4 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
287730 E/A-Modul 2: CAN-participant ABV (ABS/ASR) Data transfer subscriber transfer cycle exceeded X625:5/6 U-51.4/51.4 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
287731 E/A-Modul 2: CAN-participant ABV (ABS/ASR) Data transfer faulty/missing, max. cycle time exceeded X625:5/6 U-51.4/51.4 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
002389508 152
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
288530 E/A-Modul 2: CAN-participant E/A-Modul 1 Data transfer subscriber transfer cycle exceeded X625:5/6 U-51.4/51.4 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
288531 E/A-Modul 2: CAN-participant E/A-Modul 1 Data transfer faulty/missing, max. cycle time exceeded X625:5/6 U-51.4/51.4 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
288630 E/A-Modul 2: CAN-participant E/A-Modul 2 Data transfer subscriber transfer cycle exceeded X625:5/6 U-51.4/51.4 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
288631 E/A-Modul 2: CAN-participant E/A-Modul 2 Data transfer faulty/missing, max. cycle time exceeded X625:5/6 U-51.4/51.4 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
288930 E/A-Modul 2: CAN-participant E/A-Modul 5 Data transfer subscriber transfer cycle exceeded X625:5/6 U-51.4/51.4 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
288931 E/A-Modul 2: CAN-participant E/A-Modul 5 Data transfer faulty/missing, max. cycle time exceeded X625:5/6 U-51.4/51.4 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
289900 E/A-Modul 2: Control data transfer CAN internal error: register error CAN-controller X625:5/6 U-51.4/51.4 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul
289901 E/A-Modul 2: Control data transfer CAN internal error: RAM-error CAN-controller X625:5/6 U-51.4/51.4 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul
289902 E/A-Modul 2: Control data transfer CAN configuration error CAN-software X625:5/6 U-51.4/51.4 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul, check Software (test system ZE)
289903 E/A-Modul 2: Control data transfer CAN Transfer interrupted after continuous error X625:5/6 U-51.4/51.4 E 1
CAN-Transmission will be aborted
check bus lines/neutral point, replace neutral point or E/A-Modul
002389508 153
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
289910 E/A-Modul 2: Control data transfer CAN short-term error in bus connection X625:5/6 U-51.4/51.4 E 0
re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated
289911 E/A-Modul 2: Control data transfer CAN permanent error bus connection X625:5/6 U-51.4/51.4 E 1
cyclic re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated
289920 E/A-Modul 2: Control data transfer CAN active participant not responding X625:5/6 U-51.4/51.4 E 0
parameterised substitute values for receiver signals will be used
check error report for missing participant(s), test system ZE
289921 E/A-Modul 2: Control data transfer CAN No active subscriber responding X625:5/6 U-51.4/51.4 E 1
parameterised substitute values for receiver signals will be used
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul
289950 E/A-Modul 2: Control data transfer CAN erroneous command test system X625:5/6 U-51.4/51.4 E 1
no reaction to unknown test system control command in CAN-System Software
check Software (test system)
292000 E/A-Modul 2: control engine long-term disruption E/A-Modul <-> accelerator crane op. cab E 1
until the error is reset the engine speed setting for crane operation remains in idle
check LSB-connection ZE<>E/A-Modul, crane operators cab accelerator or connection to ZE (test system)
292001 E/A-Modul 2: control engine long-term disruption E/A-Modul <-> engine control E 1
engine control and E/A-Modul at emergency speed
engine control and E/A-Modul, check CAN-bus-connections
292225 E/A-Modul 2: control ABV incorrect system identification from control device E 2
function of brake system possibly restricted, function of ABV possibly restricted or not possible
replace electronics immediately or remove
293040 E/A-Modul 2: control hydraulic/second. power outputs feedback crane hydr. pump active in crane op. missing E 1
in case the pump is mechanically engaged, crane operation is possible
check pump pneumatic engagement mechanism, crane pump position; engage pump manually (engine OFF)
293041 E/A-Modul 2: control hydraulic/second. power outputs feedback crane hydr. pump inactive in travel op. missing E 1
in case the pump is mechanically engaged, pump can be damaged in travel operation due to excessive speed
Check pneumatic engagement mechanism of pump, position of sensor crane pump; disengage manual pump (engine OFF)
002389508 154
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
293042 E/A-Modul 2: control hydraulic/second. power outputs no signal from feedback sensor pump crane hydraulics E 1
error report, no acknowledgement on condition of the pump
check LSB-bus connection, check sensor
293150 E/A-Modul 2: instruments operators cab signal "KL15OWUW" on operation mode selector switch missing E 1
no operation mode determinable, function of upper and undercarriage partly blocked
check operation mode change-switch connection<>E/A-Modul, signals to entries from E/A-Modul; replace E/A-Modul
293151 E/A-Modul 2: instruments operators cab signal "KL15OW" on operation mode selector switch missing E 1
no operation mode determinable, function of upper and undercarriage partly blocked
check operation mode change-switch connection<>E/A-Modul, signals to entries from E/A-Modul; replace E/A-Modul
293152 E/A-Modul 2: instruments operators cab signal "KL15UW" on operation mode selector switch missing E 1
no operation mode determinable, function of upper and undercarriage partly blocked
check operation mode change-switch connection<>E/A-Modul, signals to entries from E/A-Modul; replace E/A-Modul
293153 E/A-Modul 2: instruments operators cab sig. "KL15OW" or "KL15UW" on op. type selector switch missing E 1
no operation mode determinable, function of upper and undercarriage partly blocked
check operation mode change-switch connection<>E/A-Modul, signals to entries from E/A-Modul; replace E/A-Modul
293500 E/A-Modul 2: control heating/air conditioning servo-motor heating, circulated/fresh air or screen/foot erroneous E 1
servo motor relays a high signal to the diagnosis output
check water valve and air flaps of the heating or check servo motor
002389508 155
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
294943 E/A-Modul 2: control optional device no signal from boom sensor in support E 1
control indicator for boom support flashing
check LSB-bus connection, check sensor
295050 E/A-Modul 2: operation engine no engine start possible as engine already recognized as ON B
no start signal on engine
check signals Kl50 ignition start switch and D+ alternator
295055 E/A-Modul 2: operation engine STOP, ignition operators cab in upper-carriage operation mode B
engine stop in upper-carriage operation mode
check switch position ignition start switch in driver's cab
295056 E/A-Modul 2: operation engine STOP, ignition operators cab in under-carriage operation mode B
engine stop in undercarriage operation mode
check switch position ignition start switch in crane cab
295059 E/A-Modul 2: operation engine no start, CAN-connection E/A-Modul <-> engine elec. malfunc B
no engine start possible from crane operators cab
eliminate error in CAN-bus system
295063 E/A-Modul 2: operation engine no start, engine-STOP-key activated in right support unit B
engine start not possible
check key
002389508 156
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
295064 E/A-Modul 2: operation engine no start, engine-STOP-key activated in left support unit B
engine start not possible
check key
295068 E/A-Modul 2: operation engine no start, signal to op. mode-change switch"Kl15OWUW" missing B
engine start not possible
check operation modes selection switch in driver's cab
295069 E/A-Modul 2: operation engine no start, signal to op. mode-change switch"Kl15OW" missing B
engine start not possible
check operation modes selection switch in driver's cab
295070 E/A-Modul 2: operation engine no start, signal to op. mode-change switch"Kl15UW" missing B
engine start not possible
check operation modes selection switch in driver's cab
295079 E/A-Modul 2: operation engine support box-operation mode prevented: gears not in neutral B
no switch-over, support unit blocked
switch transmission to neutral (N)
295080 E/A-Modul 2: operation engine travel operation not possible when key activated on support box B
switch-over results
check support unit keys
002389508 157
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
295914 E/A-Modul 2: operation longitudinal lock activation of function without operation mode B
function is not carried out
start engine and repeat operation
002389508 158
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
296014 E/A-Modul 2: operation transversal lock activation of function without operation mode B
function is not carried out
start engine and repeat operation
296300 E/A-Modul 2: operation steering front axle function simultaneously ON and OFF B
function is not carried out
do not simultaneously activate contrasting function keys
296666 E/A-Modul 2: operation hydraulics/second. power outputs hyd. crane system pump not engaged as compr. air supply too low B
296777 E/A-Modul 2: operation off-road gear off-road gear and transfer box free B
function is not carried out
do not disconnect transfer case in off-road gear ON or off-road gear not ON with disconnection of transfer gear
361002 E/A-Modul 3: system error OS-C167 initialising error test total in EPROM/FLASH erroneous E 2
error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul
002389508 159
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
372052 E/A-Modul 3: input/output DEA0 output open, to low load, short circuit to supply voltage X633:17 U-75.2 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
372053 E/A-Modul 3: input/output DEA0 transistor current supply insufficient or missing X633:17 U-75.2 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
372054 E/A-Modul 3: input/output DEA0 short circuit to supply voltage X633:17 U-75.2 E 1
error report on display
check output for short, if necessary replace E/A-Modul
372055 E/A-Modul 3: input/output DEA0 excessive temperature, short circuit to ground or overload X633:17 U-75.2 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
372152 E/A-Modul 3: input/output DEA1 output open, to low load, short circuit to supply voltage X633:15 U-75.3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
372153 E/A-Modul 3: input/output DEA1 transistor current supply insufficient or missing X633:15 U-75.3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
002389508 160
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
372154 E/A-Modul 3: input/output DEA1 short circuit to supply voltage X633:15 U-75.3 E 1
error report on display
check output for short, if necessary replace E/A-Modul
372155 E/A-Modul 3: input/output DEA1 excessive temperature, short circuit to ground or overload X633:15 U-75.3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
372252 E/A-Modul 3: input/output DEA2 output open, to low load, short circuit to supply voltage X633:13 U-75.3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
372253 E/A-Modul 3: input/output DEA2 transistor current supply insufficient or missing X633:13 U-75.3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
372254 E/A-Modul 3: input/output DEA2 short circuit to supply voltage X633:13 U-75.3 E 1
error report on display
check output for short, if necessary replace E/A-Modul
372255 E/A-Modul 3: input/output DEA2 excessive temperature, short circuit to ground or overload X633:13 U-75.3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
372352 E/A-Modul 3: input/output DEA3 output open, to low load, short circuit to supply voltage X633:11 U-75.4 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
372353 E/A-Modul 3: input/output DEA3 transistor current supply insufficient or missing X633:11 U-75.4 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
372354 E/A-Modul 3: input/output DEA3 short circuit to supply voltage X633:11 U-75.4 E 1
error report on display
check output for short, if necessary replace E/A-Modul
372355 E/A-Modul 3: input/output DEA3 excessive temperature, short circuit to ground or overload X633:11 U-75.4 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
002389508 161
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
372452 E/A-Modul 3: input/output DEA4 output open, to low load, short circuit to supply voltage X633:9 U-75.5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
372453 E/A-Modul 3: input/output DEA4 transistor current supply insufficient or missing X633:9 U-75.5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
372454 E/A-Modul 3: input/output DEA4 short circuit to supply voltage X633:9 U-75.5 E 1
error report on display
check output for short, if necessary replace E/A-Modul
372455 E/A-Modul 3: input/output DEA4 excessive temperature, short circuit to ground or overload X633:9 U-75.5 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
372552 E/A-Modul 3: input/output DEA5 output open, to low load, short circuit to supply voltage X633:7 U-75.6 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
372553 E/A-Modul 3: input/output DEA5 transistor current supply insufficient or missing X633:7 U-75.6 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
372554 E/A-Modul 3: input/output DEA5 short circuit to supply voltage X633:7 U-75.6 E 1
error report on display
check output for short, if necessary replace E/A-Modul
372555 E/A-Modul 3: input/output DEA5 excessive temperature, short circuit to ground or overload X633:7 U-75.6 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
372652 E/A-Modul 3: input/output DEA6 output open, to low load, short circuit to supply voltage X633:5 U-75.7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
372653 E/A-Modul 3: input/output DEA6 transistor current supply insufficient or missing X633:5 U-75.7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
002389508 162
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
372654 E/A-Modul 3: input/output DEA6 short circuit to supply voltage X633:5 U-75.7 E 1
error report on display
check output for short, if necessary replace E/A-Modul
372655 E/A-Modul 3: input/output DEA6 excessive temperature, short circuit to ground or overload X633:5 U-75.7 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
372752 E/A-Modul 3: input/output DEA7 output open, to low load, short circuit to supply voltage X633:3 U-75.7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
372753 E/A-Modul 3: input/output DEA7 transistor current supply insufficient or missing X633:3 U-75.7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
372754 E/A-Modul 3: input/output DEA7 short circuit to supply voltage X633:3 U-75.7 E 1
error report on display
check output for short, if necessary replace E/A-Modul
372755 E/A-Modul 3: input/output DEA7 excessive temperature, short circuit to ground or overload X633:3 U-75.7 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
373017 E/A-Modul 3: current input E0 voltage below required value X632:17 U-99.3 E 1
on both support operating units "E." is flashing on the display for support force front right
check input signal on the E/A-Modul or sensor
373080 E/A-Modul 3: current input E0 short circuit to ground, open line, voltage sensor erroneous X632:17 U-99.3 E 1
on both support operating units "E." is flashing on the display for support force front right
check input signal on the E/A-Modul or sensor
373117 E/A-Modul 3: current input E1 voltage below required value X632:15 U-99.1 E 1
on both support operating units "E." is flashing on the display for support force rear right
check input signal on the E/A-Modul or sensor
373180 E/A-Modul 3: current input E1 short circuit to ground, open line, voltage sensor erroneous X632:15 U-99.1 E 1
on both support operating units "E." is flashing on the display for support force rear right
check input signal on the E/A-Modul or sensor
002389508 163
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
373217 E/A-Modul 3: current input E2 voltage below required value X632:13 U-100.6 E 1
both outer LEDs for transversal inclination on both support operating units are flashing
check input signal on the E/A-Modul or sensor
373280 E/A-Modul 3: current input E2 short circuit to ground, open line, voltage sensor erroneous X632:13 U-100.6 E 1
both outer LEDs for transversal inclination on both support operating units are flashing
check input signal on the E/A-Modul or sensor
373317 E/A-Modul 3: current input E3 voltage below required value X632:11 U-100.7 E 1
both outer LEDs for longitudinal inclination are flashing on both support units
check input signal on the E/A-Modul or sensor
373380 E/A-Modul 3: current input E3 short circuit to ground, open line, voltage sensor erroneous X632:11 U-100.7 E 1
both outer LEDs for longitudinal inclination are flashing on both support units
check input signal on the E/A-Modul or sensor
373782 E/A-Modul 3: voltage input E7 short circuit to ground, open line, constant current 10 mA incorrect X632:4 U-60.7 E 1
symbol for diesel tank is flashing on the display unit, as are 3 question marks on monitor in uppercarriage
check input signal on the E/A-Modul or sensor
373783 E/A-Modul 3: voltage input E7 short circuit to supply voltage, open line, lack of voltage X632:4 U-60.7 E 1
symbol for diesel tank is flashing on the display unit, as are 3 question marks on monitor in uppercarriage
check input signal on the E/A-Modul or sensor
379052 E/A-Modul 3: output A0 output open, to low load, short circuit to supply voltage X633:18 U-76.2 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
379053 E/A-Modul 3: output A0 transistor current supply insufficient or missing X633:18 U-76.2 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
379055 E/A-Modul 3: output A0 excessive temperature, short circuit to ground or overload X633:18 U-76.2 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
002389508 164
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
379152 E/A-Modul 3: output A1 output open, to low load, short circuit to supply voltage X633:16 U-76.2 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
379153 E/A-Modul 3: output A1 transistor current supply insufficient or missing X633:16 U-76.2 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
379155 E/A-Modul 3: output A1 excessive temperature, short circuit to ground or overload X633:16 U-76.2 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
379250 E/A-Modul 3: bridge output A2 short circuit to ground, junction not supplied X633:14 U-76.3 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul
379251 E/A-Modul 3: bridge output A2 short circuit to supply voltage, excessive temperature X633:14 U-76.3 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul
379252 E/A-Modul 3: bridge output A2 output open, to low load, short circuit to supply voltage X633:14 U-76.3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
379253 E/A-Modul 3: bridge output A2 transistor current supply insufficient or missing X633:14 U-76.3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
379254 E/A-Modul 3: bridge output A2 short circuit to supply voltage X633:14 U-76.3 E 1
error report on display
check output for short, if necessary replace E/A-Modul
379255 E/A-Modul 3: bridge output A2 excessive temperature, short circuit to ground or overload X633:14 U-76.3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
002389508 165
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
379350 E/A-Modul 3: bridge output A3 short circuit to ground, junction not supplied X633:12 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul
379351 E/A-Modul 3: bridge output A3 short circuit to supply voltage, excessive temperature X633:12 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul
379352 E/A-Modul 3: bridge output A3 output open, to low load, short circuit to supply voltage X633:12 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
379353 E/A-Modul 3: bridge output A3 transistor current supply insufficient or missing X633:12 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
379355 E/A-Modul 3: bridge output A3 excessive temperature, short circuit to ground or overload X633:12 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
383501 E/A-Modul 3: SPI-support unit right Faulty data transfer E/A-module<>unit (time exceeded) X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
383502 E/A-Modul 3: SPI-support unit right Serious system error to SPI-connection (interface) X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
383503 E/A-Modul 3: SPI-support unit right break in line or short circuit to supply voltage X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary
383504 E/A-Modul 3: SPI-support unit right break in line or short circuit to ground X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary
002389508 166
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
383506 E/A-Modul 3: SPI-support unit right Data transfer faulty (faulty check byte) X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
suppress EMV- interference
383507 E/A-Modul 3: SPI-support unit right Unit faulty/missing, incorrect unit inserted (ID) X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
check periphery and replace if necessary, check Software version, check EMV- interference
383508 E/A-Modul 3: SPI-support unit right Data transfer faulty (incorrect number of data bytes received) X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
383900 E/A-Modul 3: Control operating unit (SPI) Faulty initialisation data connection E/A-module<>unit X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
383902 E/A-Modul 3: Control operating unit (SPI) Serious system error to SPI-connection (interface) X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
383905 E/A-Modul 3: Control operating unit (SPI) Initialisation error, resetting inputs/outputs faulty X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
check wiring, check periphery and replace if necessary, check E/A-Modul and replace if necessary
383907 E/A-Modul 3: Control operating unit (SPI) Unit faulty/missing, incorrect unit inserted (ID) X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
connect functional periphery unit, system then eliminates error independently
383908 E/A-Modul 3: Control operating unit (SPI) Data transfer faulty (incorrect number of data bytes received) X634:1/2/3/5/6/ U-49.7/49.6/49.5/49. E 1
error indication on display 7/8 5/49.4/49.3/49.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
384050 E/A-Modul 3: LSB-B participant address 0 reports an incorrect sensor type X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
384051 E/A-Modul 3: LSB-B participant address 0 was not configured for the block transfer X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
002389508 167
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
384053 E/A-Modul 3: LSB-B participant address 0 no longer reports or withdrawn during running period X633:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
384054 E/A-Modul 3: LSB-B participant address 0 Features other settings (parameters) as pre-entered set values X633:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
384064 E/A-Modul 3: LSB-B participant address 0 reports tolerable error in self-test X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
384065 E/A-Modul 3: LSB-B participant address 0 reports intolerable error in self-test X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
384066 E/A-Modul 3: LSB-B participant address 0 with software version, that is no longer compatible X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
384067 E/A-Modul 3: LSB-B participant address 0 supports no download function X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
384150 E/A-Modul 3: LSB-B participant address 1 reports an incorrect sensor type X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
384151 E/A-Modul 3: LSB-B participant address 1 was not configured for the block transfer X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
384153 E/A-Modul 3: LSB-B participant address 1 no longer reports or withdrawn during running period X633:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
384154 E/A-Modul 3: LSB-B participant address 1 Features other settings (parameters) as pre-entered set values X633:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
002389508 168
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
384164 E/A-Modul 3: LSB-B participant address 1 reports tolerable error in self-test X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
384165 E/A-Modul 3: LSB-B participant address 1 reports intolerable error in self-test X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
384166 E/A-Modul 3: LSB-B participant address 1 with software version, that is no longer compatible X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
384167 E/A-Modul 3: LSB-B participant address 1 supports no download function X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
384250 E/A-Modul 3: LSB-B participant address 2 reports an incorrect sensor type X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
384251 E/A-Modul 3: LSB-B participant address 2 was not configured for the block transfer X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
384253 E/A-Modul 3: LSB-B participant address 2 no longer reports or withdrawn during running period X633:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
384254 E/A-Modul 3: LSB-B participant address 2 Features other settings (parameters) as pre-entered set values X633:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
384264 E/A-Modul 3: LSB-B participant address 2 reports tolerable error in self-test X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
384265 E/A-Modul 3: LSB-B participant address 2 reports intolerable error in self-test X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
002389508 169
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
384266 E/A-Modul 3: LSB-B participant address 2 with software version, that is no longer compatible X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
384267 E/A-Modul 3: LSB-B participant address 2 supports no download function X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
384350 E/A-Modul 3: LSB-B participant address 3 reports an incorrect sensor type X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
384351 E/A-Modul 3: LSB-B participant address 3 was not configured for the block transfer X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
384353 E/A-Modul 3: LSB-B participant address 3 no longer reports or withdrawn during running period X633:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
384354 E/A-Modul 3: LSB-B participant address 3 Features other settings (parameters) as pre-entered set values X633:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
384364 E/A-Modul 3: LSB-B participant address 3 reports tolerable error in self-test X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
384365 E/A-Modul 3: LSB-B participant address 3 reports intolerable error in self-test X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
384366 E/A-Modul 3: LSB-B participant address 3 with software version, that is no longer compatible X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
384367 E/A-Modul 3: LSB-B participant address 3 supports no download function X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
002389508 170
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
384450 E/A-Modul 3: LSB-B participant address 4 reports an incorrect sensor type X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
384451 E/A-Modul 3: LSB-B participant address 4 was not configured for the block transfer X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
384453 E/A-Modul 3: LSB-B participant address 4 no longer reports or withdrawn during running period X633:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
384454 E/A-Modul 3: LSB-B participant address 4 Features other settings (parameters) as pre-entered set values X633:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
384464 E/A-Modul 3: LSB-B participant address 4 reports tolerable error in self-test X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
384465 E/A-Modul 3: LSB-B participant address 4 reports intolerable error in self-test X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
384466 E/A-Modul 3: LSB-B participant address 4 with software version, that is no longer compatible X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
384467 E/A-Modul 3: LSB-B participant address 4 supports no download function X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
384550 E/A-Modul 3: LSB-B participant address 5 reports an incorrect sensor type X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
384551 E/A-Modul 3: LSB-B participant address 5 was not configured for the block transfer X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
002389508 171
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
384553 E/A-Modul 3: LSB-B participant address 5 no longer reports or withdrawn during running period X633:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
384554 E/A-Modul 3: LSB-B participant address 5 Features other settings (parameters) as pre-entered set values X633:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
384564 E/A-Modul 3: LSB-B participant address 5 reports tolerable error in self-test X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
384565 E/A-Modul 3: LSB-B participant address 5 reports intolerable error in self-test X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
384566 E/A-Modul 3: LSB-B participant address 5 with software version, that is no longer compatible X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
384567 E/A-Modul 3: LSB-B participant address 5 supports no download function X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
384650 E/A-Modul 3: LSB-B participant address 6 reports an incorrect sensor type X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
384651 E/A-Modul 3: LSB-B participant address 6 was not configured for the block transfer X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
384653 E/A-Modul 3: LSB-B participant address 6 no longer reports or withdrawn during running period X633:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
384654 E/A-Modul 3: LSB-B participant address 6 Features other settings (parameters) as pre-entered set values X633:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
002389508 172
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
384664 E/A-Modul 3: LSB-B participant address 6 reports tolerable error in self-test X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
384665 E/A-Modul 3: LSB-B participant address 6 reports intolerable error in self-test X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
384666 E/A-Modul 3: LSB-B participant address 6 with software version, that is no longer compatible X633:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
384667 E/A-Modul 3: LSB-B participant address 6 supports no download function X633:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
387252 E/A-Modul 3: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X633:4/6 U-46.6/46.5 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor
387255 E/A-Modul 3: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X633:4/6 U-46.6/46.5 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
387256 E/A-Modul 3: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X633:4/6 U-46.6/46.5 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
387257 E/A-Modul 3: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X633:4/6 U-46.6/46.5 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part
387258 E/A-Modul 3: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X633:4/6 U-46.6/46.5 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors
387259 E/A-Modul 3: Control data transfer LSB-B recognised communication breakdown in bus X633:4/6 U-46.6/46.5 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network
002389508 173
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
387260 E/A-Modul 3: Control data transfer LSB-B driver error: no order to carry out X633:4/6 U-46.6/46.5 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software
387261 E/A-Modul 3: Control data transfer LSB-B driver error: undefined message appears X633:4/6 U-46.6/46.5 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination
387262 E/A-Modul 3: Control data transfer LSB-B driver error: initialising error X633:4/6 U-46.6/46.5 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination
392830 E/A-Modul 3: control supports location coding for right support unit erroneous (set value = 0) E 2
support functions are blocked
check line connection to E/A-Modul, check ground connection from signal, replace E/A-Modul
392832 E/A-Modul 3: control supports right support unit key sticking or activated after switching on E 1
right support blocked
check/unplug/replace support operating unit release activated key
002389508 174
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
396440 E/A-Modul 3: operation supports simultaneous UP and DOWN operation of support control unit B
function is not carried out
actuate UP key or DOWN key of the respective support operating unit, start test program support service unit
396441 E/A-Modul 3: operation supports simultaneous IN and OUT operation of support control unit B
function is not carried out
actuate OFF key or ON key of the respective support operating unit, start test program support operating unit
396442 E/A-Modul 3: operation supports simultaneous UP and DOWN operation on upper-carriage monitor B
function is not carried out
actuate UP key or DOWN key of the respective support operating unit, start test program support service unit
396443 E/A-Modul 3: operation supports simultaneous IN and OUT operation on upper-carriage monitor B
function is not carried out
actuate OFF key or ON key of the respective support operating unit, start test program support operating unit
396444 E/A-Modul 3: operation supports simultaneous left and right operation of support control unit B
function is not carried out
actuate support from only one operating position, start test program support operating unit
396445 E/A-Modul 3: operation supports simultaneous operation of support control unit and upper-carriage B
function is not carried out
actuate support from only one operating position, start test program support operating unit
396446 E/A-Modul 3: operation supports simultaneous operation of support control unit and upper-carriage B
function is not carried out
actuate support from only one operating position, start test program support operating unit
396447 E/A-Modul 3: operation supports operation of support control unit with travel direction D engaged B
function is not carried out
switch transmission to neutral (N)
002389508 175
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
396448 E/A-Modul 3: operation supports operation of support control unit with travel direction R engaged B
function is not carried out
switch transmission to neutral (N)
396449 E/A-Modul 3: operation supports op. of upper-carriage monitor with travel direction D engaged B
function is not carried out
switch transmission to neutral (N)
396451 E/A-Modul 3: operation supports unauthorised activation of right support control unit key B
right support blocked
release activated key after having authorized function through hand- key
399890 E/A-Modul 3: operation diagnosis system test program not executable as engine is not OFF B
function is not carried out
shut down engine
399892 E/A-Modul 3: operation diagnosis system test program not executable as not in under-carriage op. mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode
461002 E/A-Modul 4: system error OS-C167 initialising error test total in EPROM/FLASH erroneous E 2
error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul
002389508 176
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
472052 E/A-Modul 4: input/output DEA0 output open, to low load, short circuit to supply voltage X643:17 U-74.2 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
472053 E/A-Modul 4: input/output DEA0 transistor current supply insufficient or missing X643:17 U-74.2 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
472054 E/A-Modul 4: input/output DEA0 short circuit to supply voltage X643:17 U-74.2 E 1
error report on display
check output for short, if necessary replace E/A-Modul
472055 E/A-Modul 4: input/output DEA0 excessive temperature, short circuit to ground or overload X643:17 U-74.2 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
472152 E/A-Modul 4: input/output DEA1 output open, to low load, short circuit to supply voltage X643:15 U-74.3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
472153 E/A-Modul 4: input/output DEA1 transistor current supply insufficient or missing X643:15 U-74.3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
002389508 177
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
472154 E/A-Modul 4: input/output DEA1 short circuit to supply voltage X643:15 U-74.3 E 1
error report on display
check output for short, if necessary replace E/A-Modul
472155 E/A-Modul 4: input/output DEA1 excessive temperature, short circuit to ground or overload X643:15 U-74.3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
472252 E/A-Modul 4: input/output DEA2 output open, to low load, short circuit to supply voltage X643:13 U-74.3 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
472253 E/A-Modul 4: input/output DEA2 transistor current supply insufficient or missing X643:13 U-74.3 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
472254 E/A-Modul 4: input/output DEA2 short circuit to supply voltage X643:13 U-74.3 E 1
error report on display
check output for short, if necessary replace E/A-Modul
472255 E/A-Modul 4: input/output DEA2 excessive temperature, short circuit to ground or overload X643:13 U-74.3 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
472352 E/A-Modul 4: input/output DEA3 output open, to low load, short circuit to supply voltage X643:11 U-74.4 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
472353 E/A-Modul 4: input/output DEA3 transistor current supply insufficient or missing X643:11 U-74.4 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
472354 E/A-Modul 4: input/output DEA3 short circuit to supply voltage X643:11 U-74.4 E 1
error report on display
check output for short, if necessary replace E/A-Modul
472355 E/A-Modul 4: input/output DEA3 excessive temperature, short circuit to ground or overload X643:11 U-74.4 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
002389508 178
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
472452 E/A-Modul 4: input/output DEA4 output open, to low load, short circuit to supply voltage X643:9 U-74.5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
472453 E/A-Modul 4: input/output DEA4 transistor current supply insufficient or missing X643:9 U-74.5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
472454 E/A-Modul 4: input/output DEA4 short circuit to supply voltage X643:9 U-74.5 E 1
error report on display
check output for short, if necessary replace E/A-Modul
472455 E/A-Modul 4: input/output DEA4 excessive temperature, short circuit to ground or overload X643:9 U-74.5 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
472552 E/A-Modul 4: input/output DEA5 output open, to low load, short circuit to supply voltage X643:7 U-74.6 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
472553 E/A-Modul 4: input/output DEA5 transistor current supply insufficient or missing X643:7 U-74.6 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
472554 E/A-Modul 4: input/output DEA5 short circuit to supply voltage X643:7 U-74.6 E 1
error report on display
check output for short, if necessary replace E/A-Modul
472555 E/A-Modul 4: input/output DEA5 excessive temperature, short circuit to ground or overload X643:7 U-74.6 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
472652 E/A-Modul 4: input/output DEA6 output open, to low load, short circuit to supply voltage X643:5 U-74.7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
472653 E/A-Modul 4: input/output DEA6 transistor current supply insufficient or missing X643:5 U-74.7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
002389508 179
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
472654 E/A-Modul 4: input/output DEA6 short circuit to supply voltage X643:5 U-74.7 E 1
error report on display
check output for short, if necessary replace E/A-Modul
472655 E/A-Modul 4: input/output DEA6 excessive temperature, short circuit to ground or overload X643:5 U-74.7 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
472752 E/A-Modul 4: input/output DEA7 output open, to low load, short circuit to supply voltage X643:3 U-74.7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
472753 E/A-Modul 4: input/output DEA7 transistor current supply insufficient or missing X643:3 U-74.7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
472754 E/A-Modul 4: input/output DEA7 short circuit to supply voltage X643:3 U-74.7 E 1
error report on display
check output for short, if necessary replace E/A-Modul
472755 E/A-Modul 4: input/output DEA7 excessive temperature, short circuit to ground or overload X643:3 U-74.7 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
473017 E/A-Modul 4: current input E0 voltage below required value X642:17 U-99.5 E 1
on both support operating units "E." is flashing on the display for support force front left
check input signal on the E/A-Modul or sensor
473080 E/A-Modul 4: current input E0 short circuit to ground, open line, voltage sensor erroneous X642:17 U-99.5 E 1
on both support operating units "E." is flashing on the display for support force front left
check input signal on the E/A-Modul or sensor
473117 E/A-Modul 4: current input E1 voltage below required value X642:15 U-99.7 E 1
on both support operating units "E." is flashing on the display for support force rear left
check input signal on the E/A-Modul or sensor
473180 E/A-Modul 4: current input E1 short circuit to ground, open line, voltage sensor erroneous X642:15 U-99.7 E 1
on both support operating units "E." is flashing on the display for support force rear left
check input signal on the E/A-Modul or sensor
002389508 180
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
479052 E/A-Modul 4: output A0 output open, to low load, short circuit to supply voltage X643:18 U-73.6 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
479053 E/A-Modul 4: output A0 transistor current supply insufficient or missing X643:18 U-73.6 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
479055 E/A-Modul 4: output A0 excessive temperature, short circuit to ground or overload X643:18 U-73.6 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
479152 E/A-Modul 4: output A1 output open, to low load, short circuit to supply voltage X643:16 U-73.5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
479153 E/A-Modul 4: output A1 transistor current supply insufficient or missing X643:16 U-73.5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
479155 E/A-Modul 4: output A1 excessive temperature, short circuit to ground or overload X643:16 U-73.5 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
479250 E/A-Modul 4: bridge output A2 short circuit to ground, junction not supplied X643:14 U-73.7 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul
479251 E/A-Modul 4: bridge output A2 short circuit to supply voltage, excessive temperature X643:14 U-73.7 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul
002389508 181
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
479252 E/A-Modul 4: bridge output A2 output open, to low load, short circuit to supply voltage X643:14 U-73.7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
479253 E/A-Modul 4: bridge output A2 transistor current supply insufficient or missing X643:14 U-73.7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
479254 E/A-Modul 4: bridge output A2 short circuit to supply voltage X643:14 U-73.7 E 1
error report on display
check output for short, if necessary replace E/A-Modul
479255 E/A-Modul 4: bridge output A2 excessive temperature, short circuit to ground or overload X643:14 U-73.7 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
479350 E/A-Modul 4: bridge output A3 short circuit to ground, junction not supplied X643:12 U-73.7 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul
479351 E/A-Modul 4: bridge output A3 short circuit to supply voltage, excessive temperature X643:12 U-73.7 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul
479352 E/A-Modul 4: bridge output A3 output open, to low load, short circuit to supply voltage X643:12 U-73.7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
479353 E/A-Modul 4: bridge output A3 transistor current supply insufficient or missing X643:12 U-73.7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
479354 E/A-Modul 4: bridge output A3 short circuit to supply voltage X643:12 U-73.7 E 1
error report on display
check output for short, if necessary replace E/A-Modul
479355 E/A-Modul 4: bridge output A3 excessive temperature, short circuit to ground or overload X643:12 U-73.7 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
002389508 182
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
483601 E/A-Modul 4: SPI-support unit left Faulty data transfer E/A-module<>unit (time exceeded) X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
483602 E/A-Modul 4: SPI-support unit left Serious system error to SPI-connection (interface) X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
483603 E/A-Modul 4: SPI-support unit left break in line or short circuit to supply voltage X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary
483604 E/A-Modul 4: SPI-support unit left break in line or short circuit to ground X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
remedy short circuit, check periphery and replace if necessary, check E/A-Modul and replace if necessary
483606 E/A-Modul 4: SPI-support unit left Data transfer faulty (faulty check byte) X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
suppress EMV- interference
483607 E/A-Modul 4: SPI-support unit left Unit faulty/missing, incorrect unit inserted (ID) X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
check periphery and replace if necessary, check Software version, check EMV- interference
483608 E/A-Modul 4: SPI-support unit left Data transfer faulty (incorrect number of data bytes received) X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
483900 E/A-Modul 4: Control operating unit (SPI) Faulty initialisation data connection E/A-module<>unit X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
483902 E/A-Modul 4: Control operating unit (SPI) Serious system error to SPI-connection (interface) X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
483905 E/A-Modul 4: Control operating unit (SPI) Initialisation error, resetting inputs/outputs faulty X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
check wiring, check periphery and replace if necessary, check E/A-Modul and replace if necessary
002389508 183
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
483907 E/A-Modul 4: Control operating unit (SPI) Unit faulty/missing, incorrect unit inserted (ID) X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
connect functional periphery unit, system then eliminates error independently
483908 E/A-Modul 4: Control operating unit (SPI) Data transfer faulty (incorrect number of data bytes received) X644:1/2/3/5/6/ U-50.7/50.6/50.5/50. E 1
error indication on display 7/8 5/50.4/50.3/50.2
independent re-start SPI-driver and error condition elimination; with regular occurrence replace E/A-Modul
484050 E/A-Modul 4: LSB-B participant address 0 reports an incorrect sensor type X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
484051 E/A-Modul 4: LSB-B participant address 0 was not configured for the block transfer X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
484053 E/A-Modul 4: LSB-B participant address 0 no longer reports or withdrawn during running period X643:4/6 U-46.8/46.7 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
484054 E/A-Modul 4: LSB-B participant address 0 Features other settings (parameters) as pre-entered set values X643:4/6 U-46.8/46.7 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
484064 E/A-Modul 4: LSB-B participant address 0 reports tolerable error in self-test X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
484065 E/A-Modul 4: LSB-B participant address 0 reports intolerable error in self-test X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
484066 E/A-Modul 4: LSB-B participant address 0 with software version, that is no longer compatible X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
484067 E/A-Modul 4: LSB-B participant address 0 supports no download function X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
002389508 184
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
484150 E/A-Modul 4: LSB-B participant address 1 reports an incorrect sensor type X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
484151 E/A-Modul 4: LSB-B participant address 1 was not configured for the block transfer X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
484153 E/A-Modul 4: LSB-B participant address 1 no longer reports or withdrawn during running period X643:4/6 U-46.8/46.7 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
484154 E/A-Modul 4: LSB-B participant address 1 Features other settings (parameters) as pre-entered set values X643:4/6 U-46.8/46.7 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
484164 E/A-Modul 4: LSB-B participant address 1 reports tolerable error in self-test X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
484165 E/A-Modul 4: LSB-B participant address 1 reports intolerable error in self-test X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
484166 E/A-Modul 4: LSB-B participant address 1 with software version, that is no longer compatible X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
484167 E/A-Modul 4: LSB-B participant address 1 supports no download function X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
484250 E/A-Modul 4: LSB-B participant address 2 reports an incorrect sensor type X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
484251 E/A-Modul 4: LSB-B participant address 2 was not configured for the block transfer X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
002389508 185
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
484253 E/A-Modul 4: LSB-B participant address 2 no longer reports or withdrawn during running period X643:4/6 U-46.8/46.7 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
484254 E/A-Modul 4: LSB-B participant address 2 Features other settings (parameters) as pre-entered set values X643:4/6 U-46.8/46.7 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
484264 E/A-Modul 4: LSB-B participant address 2 reports tolerable error in self-test X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
484265 E/A-Modul 4: LSB-B participant address 2 reports intolerable error in self-test X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
484266 E/A-Modul 4: LSB-B participant address 2 with software version, that is no longer compatible X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
484267 E/A-Modul 4: LSB-B participant address 2 supports no download function X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
484350 E/A-Modul 4: LSB-B participant address 3 reports an incorrect sensor type X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
484351 E/A-Modul 4: LSB-B participant address 3 was not configured for the block transfer X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
484353 E/A-Modul 4: LSB-B participant address 3 no longer reports or withdrawn during running period X643:4/6 U-46.8/46.7 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
484354 E/A-Modul 4: LSB-B participant address 3 Features other settings (parameters) as pre-entered set values X643:4/6 U-46.8/46.7 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
002389508 186
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
484364 E/A-Modul 4: LSB-B participant address 3 reports tolerable error in self-test X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
484365 E/A-Modul 4: LSB-B participant address 3 reports intolerable error in self-test X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
484366 E/A-Modul 4: LSB-B participant address 3 with software version, that is no longer compatible X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
484367 E/A-Modul 4: LSB-B participant address 3 supports no download function X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
484450 E/A-Modul 4: LSB-B participant address 4 reports an incorrect sensor type X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
484451 E/A-Modul 4: LSB-B participant address 4 was not configured for the block transfer X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
484453 E/A-Modul 4: LSB-B participant address 4 no longer reports or withdrawn during running period X643:4/6 U-46.8/46.7 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
484454 E/A-Modul 4: LSB-B participant address 4 Features other settings (parameters) as pre-entered set values X643:4/6 U-46.8/46.7 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
484464 E/A-Modul 4: LSB-B participant address 4 reports tolerable error in self-test X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
484465 E/A-Modul 4: LSB-B participant address 4 reports intolerable error in self-test X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
002389508 187
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
484466 E/A-Modul 4: LSB-B participant address 4 with software version, that is no longer compatible X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
484467 E/A-Modul 4: LSB-B participant address 4 supports no download function X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
484550 E/A-Modul 4: LSB-B participant address 5 reports an incorrect sensor type X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
484551 E/A-Modul 4: LSB-B participant address 5 was not configured for the block transfer X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
484553 E/A-Modul 4: LSB-B participant address 5 no longer reports or withdrawn during running period X643:4/6 U-46.8/46.7 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
484554 E/A-Modul 4: LSB-B participant address 5 Features other settings (parameters) as pre-entered set values X643:4/6 U-46.8/46.7 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
484564 E/A-Modul 4: LSB-B participant address 5 reports tolerable error in self-test X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
484565 E/A-Modul 4: LSB-B participant address 5 reports intolerable error in self-test X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
484566 E/A-Modul 4: LSB-B participant address 5 with software version, that is no longer compatible X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
484567 E/A-Modul 4: LSB-B participant address 5 supports no download function X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
002389508 188
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
484650 E/A-Modul 4: LSB-B participant address 6 reports an incorrect sensor type X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
484651 E/A-Modul 4: LSB-B participant address 6 was not configured for the block transfer X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
484653 E/A-Modul 4: LSB-B participant address 6 no longer reports or withdrawn during running period X643:4/6 U-46.8/46.7 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
484654 E/A-Modul 4: LSB-B participant address 6 Features other settings (parameters) as pre-entered set values X643:4/6 U-46.8/46.7 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
484664 E/A-Modul 4: LSB-B participant address 6 reports tolerable error in self-test X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
484665 E/A-Modul 4: LSB-B participant address 6 reports intolerable error in self-test X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
484666 E/A-Modul 4: LSB-B participant address 6 with software version, that is no longer compatible X643:4/6 U-46.8/46.7 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
484667 E/A-Modul 4: LSB-B participant address 6 supports no download function X643:4/6 U-46.8/46.7 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
487252 E/A-Modul 4: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X643:4/6 U-46.8/46.7 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor
487255 E/A-Modul 4: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X643:4/6 U-46.8/46.7 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
002389508 189
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
487256 E/A-Modul 4: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X643:4/6 U-46.8/46.7 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
487257 E/A-Modul 4: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X643:4/6 U-46.8/46.7 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part
487258 E/A-Modul 4: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X643:4/6 U-46.8/46.7 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors
487259 E/A-Modul 4: Control data transfer LSB-B recognised communication breakdown in bus X643:4/6 U-46.8/46.7 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network
487260 E/A-Modul 4: Control data transfer LSB-B driver error: no order to carry out X643:4/6 U-46.8/46.7 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software
487261 E/A-Modul 4: Control data transfer LSB-B driver error: undefined message appears X643:4/6 U-46.8/46.7 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination
487262 E/A-Modul 4: Control data transfer LSB-B driver error: initialising error X643:4/6 U-46.8/46.7 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination
492747 E/A-Modul 4: control steering signal from steering pump flow switch erroneous E 1
control indicator for steering pump flashing
check line connections, power supply 10 mA from E/A-Modul; replace sensor or E/A-Modul
492748 E/A-Modul 4: control steering signal from auxiliary steering pump flow switch erroneous E 1
control indicator for auxiliary steering pump flashing
check line connections, power supply 10 mA from E/A-Modul; replace sensor or E/A-Modul
492831 E/A-Modul 4: control supports location coding for left support unit erroneous (set value = 1) E 2
support functions are blocked
check line connection to E/A-Modul, check power supply from signal, replace E/A-Modul
002389508 190
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
492833 E/A-Modul 4: control supports left support unit key sticking or activated after switching on E 1
left support blocked
check/unplug/replace support operating unit release activated key
496100 E/A-Modul 4: operation unlocking rear axle function simultaneously ON and OFF B
function is not carried out
do not simultaneously activate contrasting function keys
496112 E/A-Modul 4: operation unlocking rear axle unauthorised switching off of function B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)
002389508 191
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
496114 E/A-Modul 4: operation unlocking rear axle activation of function without operation mode B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)
496160 E/A-Modul 4: operation unlocking rear axle undefined condition: simultaneously locked and unlocked B
function is not carried out
check unlocking condition, Check locking limit switch and unlocking limit switch
496200 E/A-Modul 4: operation steering rear axle function simultaneously ON and OFF B
function is not carried out
do not simultaneously activate contrasting function keys
496214 E/A-Modul 4: operation steering rear axle activation of function without operation mode B
function is not carried out
check coding of E/A-Modul 3 and E/A-Modul 4 (see electric circuit diagram)
496440 E/A-Modul 4: operation supports simultaneous UP and DOWN operation of support control unit B
function is not carried out
actuate UP key or DOWN key of the respective support operating unit, start test program support service unit
496441 E/A-Modul 4: operation supports simultaneous IN and OUT operation of support control unit B
function is not carried out
actuate OFF key or ON key of the respective support operating unit, start test program support operating unit
496442 E/A-Modul 4: operation supports simultaneous UP and DOWN operation on upper-carriage monitor B
function is not carried out
actuate UP key or DOWN key of the respective support operating unit, start test program support service unit
002389508 192
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
496443 E/A-Modul 4: operation supports simultaneous IN and OUT operation on upper-carriage monitor B
function is not carried out
actuate OFF key or ON key of the respective support operating unit, start test program support operating unit
496444 E/A-Modul 4: operation supports simultaneous left and right operation of support control unit B
function is not carried out
activate support from only one operating position or start test program support operating unit
496445 E/A-Modul 4: operation supports simultaneous operation of support control unit and upper-carriage B
function is not carried out
activate support from only one operating position or start test program support operating unit
496446 E/A-Modul 4: operation supports simultaneous operation of support control unit and upper-carriage B
function is not carried out
activate support from only one operating position or start test program support operating unit
496447 E/A-Modul 4: operation supports operation of support control unit with travel direction D engaged B
function is not carried out
switch transmission to neutral (N)
496448 E/A-Modul 4: operation supports operation of support control unit with travel direction R engaged B
function is not carried out
switch transmission to neutral (N)
496449 E/A-Modul 4: operation supports op. of upper-carriage monitor with travel direction D engaged B
function is not carried out
switch transmission to neutral (N)
496452 E/A-Modul 4: operation supports unauthorised activation of left support control unit key B
left support blocked
release activated key after having authorized function through hand- key
499890 E/A-Modul 4: operation diagnosis system test program not executable as engine is not OFF B
function is not carried out
shut down engine
002389508 193
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
499892 E/A-Modul 4: operation diagnosis system test program not executable as not in under-carriage op. mode B
function is not carried out
switch over uppercarriage/undercarriage-change-switch to undercarriage operation mode
561002 E/A-Modul 5: system error OS-C167 initialising error test total in EPROM/FLASH erroneous E 2
error indication on display
ignition On/Off, with regular occurrence --> replace E/A-Modul
572052 E/A-Modul 5: input/output DEA0 output open, to low load, short circuit to supply voltage X653:17 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
002389508 194
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
572053 E/A-Modul 5: input/output DEA0 transistor current supply insufficient or missing X653:17 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
572055 E/A-Modul 5: input/output DEA0 excessive temperature, short circuit to ground or overload X653:17 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
572152 E/A-Modul 5: input/output DEA1 output open, to low load, short circuit to supply voltage X653:15 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
572153 E/A-Modul 5: input/output DEA1 transistor current supply insufficient or missing X653:15 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
572155 E/A-Modul 5: input/output DEA1 excessive temperature, short circuit to ground or overload X653:15 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
572252 E/A-Modul 5: input/output DEA2 output open, to low load, short circuit to supply voltage X653:13 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
572253 E/A-Modul 5: input/output DEA2 transistor current supply insufficient or missing X653:13 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
002389508 195
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
572255 E/A-Modul 5: input/output DEA2 excessive temperature, short circuit to ground or overload X653:13 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
572352 E/A-Modul 5: input/output DEA3 output open, to low load, short circuit to supply voltage X653:11 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
572353 E/A-Modul 5: input/output DEA3 transistor current supply insufficient or missing X653:11 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
572355 E/A-Modul 5: input/output DEA3 excessive temperature, short circuit to ground or overload X653:11 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
572452 E/A-Modul 5: input/output DEA4 output open, to low load, short circuit to supply voltage X653:9 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
572453 E/A-Modul 5: input/output DEA4 transistor current supply insufficient or missing X653:9 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
572455 E/A-Modul 5: input/output DEA4 excessive temperature, short circuit to ground or overload X653:9 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
572552 E/A-Modul 5: input/output DEA5 output open, to low load, short circuit to supply voltage X653:7 U-58.5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
002389508 196
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
572553 E/A-Modul 5: input/output DEA5 transistor current supply insufficient or missing X653:7 U-58.5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
572554 E/A-Modul 5: input/output DEA5 short circuit to supply voltage X653:7 U-58.5 E 1
error report on display
check output for short, if necessary replace E/A-Modul
572555 E/A-Modul 5: input/output DEA5 excessive temperature, short circuit to ground or overload X653:7 U-58.5 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
572652 E/A-Modul 5: input/output DEA6 output open, to low load, short circuit to supply voltage X653:5 U-67.7 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
572653 E/A-Modul 5: input/output DEA6 transistor current supply insufficient or missing X653:5 U-67.7 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
572654 E/A-Modul 5: input/output DEA6 short circuit to supply voltage X653:5 U-67.7 E 1
error report on display
check output for short, if necessary replace E/A-Modul
572655 E/A-Modul 5: input/output DEA6 excessive temperature, short circuit to ground or overload X653:5 U-67.7 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
572752 E/A-Modul 5: input/output DEA7 output open, to low load, short circuit to supply voltage X653:3 U-67.6 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
572753 E/A-Modul 5: input/output DEA7 transistor current supply insufficient or missing X653:3 U-67.6 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
572754 E/A-Modul 5: input/output DEA7 short circuit to supply voltage X653:3 U-67.6 E 1
error report on display
check output for short, if necessary replace E/A-Modul
002389508 197
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
572755 E/A-Modul 5: input/output DEA7 excessive temperature, short circuit to ground or overload X653:3 U-67.6 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
579052 E/A-Modul 5: output A0 output open, to low load, short circuit to supply voltage X653:18 U-58.2 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
579053 E/A-Modul 5: output A0 transistor current supply insufficient or missing X653:18 U-58.2 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
579055 E/A-Modul 5: output A0 excessive temperature, short circuit to ground or overload X653:18 U-58.2 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
579152 E/A-Modul 5: output A1 output open, to low load, short circuit to supply voltage X653:16 U-58.5 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
579153 E/A-Modul 5: output A1 transistor current supply insufficient or missing X653:16 U-58.5 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
579155 E/A-Modul 5: output A1 excessive temperature, short circuit to ground or overload X653:16 U-58.5 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
579250 E/A-Modul 5: bridge output A2 short circuit to ground, junction not supplied X653:14 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul
002389508 198
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
579251 E/A-Modul 5: bridge output A2 short circuit to supply voltage, excessive temperature X653:14 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul
579252 E/A-Modul 5: bridge output A2 output open, to low load, short circuit to supply voltage X653:14 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
579253 E/A-Modul 5: bridge output A2 transistor current supply insufficient or missing X653:14 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
579255 E/A-Modul 5: bridge output A2 excessive temperature, short circuit to ground or overload X653:14 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
579350 E/A-Modul 5: bridge output A3 short circuit to ground, junction not supplied X653:12 E 1
error report on display
check output for short, check current supply of load, if necessary replace E/A-Modul
579351 E/A-Modul 5: bridge output A3 short circuit to supply voltage, excessive temperature X653:12 E 1
error report on display
check output for short, check output load (measure load current), if necessary replace E/A-Modul
579352 E/A-Modul 5: bridge output A3 output open, to low load, short circuit to supply voltage X653:12 E 1
error report on display
check output for broken wire, check load on output (measure load current), if necessary replace E/A-Modul
579353 E/A-Modul 5: bridge output A3 transistor current supply insufficient or missing X653:12 E 1
error report on display
check current supply and fuse E/A-Modul, if necessary replace E/A-Modul
002389508 199
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
579355 E/A-Modul 5: bridge output A3 excessive temperature, short circuit to ground or overload X653:12 E 1
error report on display
check output for shorts, check power supply/fuse of E/A-Modul, if necessary replace E/A-Modul
584050 E/A-Modul 5: LSB-B participant address 0 reports an incorrect sensor type X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
584051 E/A-Modul 5: LSB-B participant address 0 was not configured for the block transfer X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
584053 E/A-Modul 5: LSB-B participant address 0 no longer reports or withdrawn during running period X653:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
584054 E/A-Modul 5: LSB-B participant address 0 Features other settings (parameters) as pre-entered set values X653:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
584064 E/A-Modul 5: LSB-B participant address 0 reports tolerable error in self-test X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
584065 E/A-Modul 5: LSB-B participant address 0 reports intolerable error in self-test X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
584066 E/A-Modul 5: LSB-B participant address 0 with software version, that is no longer compatible X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
584067 E/A-Modul 5: LSB-B participant address 0 supports no download function X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
584150 E/A-Modul 5: LSB-B participant address 1 reports an incorrect sensor type X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
002389508 200
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
584151 E/A-Modul 5: LSB-B participant address 1 was not configured for the block transfer X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
584153 E/A-Modul 5: LSB-B participant address 1 no longer reports or withdrawn during running period X653:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
584154 E/A-Modul 5: LSB-B participant address 1 Features other settings (parameters) as pre-entered set values X653:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
584164 E/A-Modul 5: LSB-B participant address 1 reports tolerable error in self-test X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
584165 E/A-Modul 5: LSB-B participant address 1 reports intolerable error in self-test X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
584166 E/A-Modul 5: LSB-B participant address 1 with software version, that is no longer compatible X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
584167 E/A-Modul 5: LSB-B participant address 1 supports no download function X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
584250 E/A-Modul 5: LSB-B participant address 2 reports an incorrect sensor type X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
584251 E/A-Modul 5: LSB-B participant address 2 was not configured for the block transfer X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
584253 E/A-Modul 5: LSB-B participant address 2 no longer reports or withdrawn during running period X653:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
002389508 201
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
584254 E/A-Modul 5: LSB-B participant address 2 Features other settings (parameters) as pre-entered set values X653:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
584264 E/A-Modul 5: LSB-B participant address 2 reports tolerable error in self-test X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
584265 E/A-Modul 5: LSB-B participant address 2 reports intolerable error in self-test X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
584266 E/A-Modul 5: LSB-B participant address 2 with software version, that is no longer compatible X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
584267 E/A-Modul 5: LSB-B participant address 2 supports no download function X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
584350 E/A-Modul 5: LSB-B participant address 3 reports an incorrect sensor type X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
584351 E/A-Modul 5: LSB-B participant address 3 was not configured for the block transfer X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
584353 E/A-Modul 5: LSB-B participant address 3 no longer reports or withdrawn during running period X653:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
584354 E/A-Modul 5: LSB-B participant address 3 Features other settings (parameters) as pre-entered set values X653:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
584364 E/A-Modul 5: LSB-B participant address 3 reports tolerable error in self-test X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
002389508 202
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
584365 E/A-Modul 5: LSB-B participant address 3 reports intolerable error in self-test X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
584366 E/A-Modul 5: LSB-B participant address 3 with software version, that is no longer compatible X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
584367 E/A-Modul 5: LSB-B participant address 3 supports no download function X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
584450 E/A-Modul 5: LSB-B participant address 4 reports an incorrect sensor type X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
584451 E/A-Modul 5: LSB-B participant address 4 was not configured for the block transfer X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
584453 E/A-Modul 5: LSB-B participant address 4 no longer reports or withdrawn during running period X653:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
584454 E/A-Modul 5: LSB-B participant address 4 Features other settings (parameters) as pre-entered set values X653:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
584464 E/A-Modul 5: LSB-B participant address 4 reports tolerable error in self-test X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
584465 E/A-Modul 5: LSB-B participant address 4 reports intolerable error in self-test X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
584466 E/A-Modul 5: LSB-B participant address 4 with software version, that is no longer compatible X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
002389508 203
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
584467 E/A-Modul 5: LSB-B participant address 4 supports no download function X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
584550 E/A-Modul 5: LSB-B participant address 5 reports an incorrect sensor type X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
584551 E/A-Modul 5: LSB-B participant address 5 was not configured for the block transfer X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
584553 E/A-Modul 5: LSB-B participant address 5 no longer reports or withdrawn during running period X653:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
584554 E/A-Modul 5: LSB-B participant address 5 Features other settings (parameters) as pre-entered set values X653:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
584564 E/A-Modul 5: LSB-B participant address 5 reports tolerable error in self-test X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
584565 E/A-Modul 5: LSB-B participant address 5 reports intolerable error in self-test X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
584566 E/A-Modul 5: LSB-B participant address 5 with software version, that is no longer compatible X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
584567 E/A-Modul 5: LSB-B participant address 5 supports no download function X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
584650 E/A-Modul 5: LSB-B participant address 6 reports an incorrect sensor type X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the answer will be interpreted according to the set type characteristics
check address assignment over test system (LSB-screen), install correct sensor
002389508 204
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
584651 E/A-Modul 5: LSB-B participant address 6 was not configured for the block transfer X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, no block transfer will be carried out
configuration problem, load new Software
584653 E/A-Modul 5: LSB-B participant address 6 no longer reports or withdrawn during running period X653:4/6 U-46.6/46.5 E 1
entry in error memory, participant will be deactivated, data buffer to the application will be set to 0
check connection, if connection OK then replace sensor
584654 E/A-Modul 5: LSB-B participant address 6 Features other settings (parameters) as pre-entered set values X653:4/6 U-46.6/46.5 E 2
entry in error memory, or no reaction, the sensor data could be incorrect, due to incorrect sensor config
check parameter set/real value through test system (LSB-screen), set sensor to default value
584664 E/A-Modul 5: LSB-B participant address 6 reports tolerable error in self-test X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction; note only: sensor still functions correctly
check sensor, clean if necessary, with repeated occurrence replace sensor
584665 E/A-Modul 5: LSB-B participant address 6 reports intolerable error in self-test X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, the error free operation is no longer guaranteed
replace sensor immediately
584666 E/A-Modul 5: LSB-B participant address 6 with software version, that is no longer compatible X653:4/6 U-46.6/46.5 E 2
entry in error memory, otherwise no reaction, it will be tried as far as possible to work with the sensor
replace sensor through new part
584667 E/A-Modul 5: LSB-B participant address 6 supports no download function X653:4/6 U-46.6/46.5 E 1
entry in error memory, otherwise no reaction, no download can be carried out
no download to be carried out
587252 E/A-Modul 5: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X653:4/6 U-46.6/46.5 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor
587255 E/A-Modul 5: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X653:4/6 U-46.6/46.5 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
587256 E/A-Modul 5: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X653:4/6 U-46.6/46.5 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
002389508 205
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
587257 E/A-Modul 5: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X653:4/6 U-46.6/46.5 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part
587258 E/A-Modul 5: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X653:4/6 U-46.6/46.5 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors
587259 E/A-Modul 5: Control data transfer LSB-B recognised communication breakdown in bus X653:4/6 U-46.6/46.5 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network
587260 E/A-Modul 5: Control data transfer LSB-B driver error: no order to carry out X653:4/6 U-46.6/46.5 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software
587261 E/A-Modul 5: Control data transfer LSB-B driver error: undefined message appears X653:4/6 U-46.6/46.5 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination
587262 E/A-Modul 5: Control data transfer LSB-B driver error: initialising error X653:4/6 U-46.6/46.5 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination
587530 E/A-Modul 5: CAN-participant engine Data transfer subscriber transfer cycle exceeded X655:5/6 U-51.6/51.7 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
587531 E/A-Modul 5: CAN-participant engine Data transfer faulty/missing, max. cycle time exceeded X655:5/6 U-51.6/51.7 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
587630 E/A-Modul 5: CAN-participant gear Data transfer subscriber transfer cycle exceeded X655:5/6 U-51.6/51.7 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
587631 E/A-Modul 5: CAN-participant gear Data transfer faulty/missing, max. cycle time exceeded X655:5/6 U-51.6/51.7 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
002389508 206
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
587730 E/A-Modul 5: CAN-participant ABV (ABS/ASR) Data transfer subscriber transfer cycle exceeded X655:5/6 U-51.6/51.7 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
587731 E/A-Modul 5: CAN-participant ABV (ABS/ASR) Data transfer faulty/missing, max. cycle time exceeded X655:5/6 U-51.6/51.7 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
588530 E/A-Modul 5: CAN-participant E/A-Modul 1 Data transfer subscriber transfer cycle exceeded X655:5/6 U-51.6/51.7 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
588531 E/A-Modul 5: CAN-participant E/A-Modul 1 Data transfer faulty/missing, max. cycle time exceeded X655:5/6 U-51.6/51.7 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
588930 E/A-Modul 5: CAN-participant E/A-Modul 5 Data transfer subscriber transfer cycle exceeded X655:5/6 U-51.6/51.7 E 0
CAN-Information from participant has exceeded the defined cycle time
check bus lines/neutral point, check defective bus participant
588931 E/A-Modul 5: CAN-participant E/A-Modul 5 Data transfer faulty/missing, max. cycle time exceeded X655:5/6 U-51.6/51.7 E 1
parameterised substitute values for receiver signals will be used
check bus lines/neutral point, check defective bus participant
589900 E/A-Modul 5: Control data transfer CAN internal error: register error CAN-controller X655:5/6 U-51.6/51.7 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul
589901 E/A-Modul 5: Control data transfer CAN internal error: RAM-error CAN-controller X655:5/6 U-51.6/51.7 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul
589902 E/A-Modul 5: Control data transfer CAN configuration error CAN-software X655:5/6 U-51.6/51.7 E 2
internal error, CAN-transmission will be aborted
replace E/A-Modul, check Software (test system ZE)
589903 E/A-Modul 5: Control data transfer CAN Transfer interrupted after continuous error X655:5/6 U-51.6/51.7 E 1
CAN-Transmission will be aborted
check bus lines/neutral point, replace neutral point or E/A-Modul
002389508 207
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
589910 E/A-Modul 5: Control data transfer CAN short-term error in bus connection X655:5/6 U-51.6/51.7 E 0
re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated
589911 E/A-Modul 5: Control data transfer CAN permanent error bus connection X655:5/6 U-51.6/51.7 E 1
cyclic re-attachment of Modul to bus transmission
check bus lines/neutral point, unplug individual bus participant and check if error has been eliminated
589920 E/A-Modul 5: Control data transfer CAN active participant not responding X655:5/6 U-51.6/51.7 E 0
parameterised substitute values for receiver signals will be used
check error report for missing participant(s), test system ZE
589921 E/A-Modul 5: Control data transfer CAN No active subscriber responding X655:5/6 U-51.6/51.7 E 1
parameterised substitute values for receiver signals will be used
in case bus system is error free, check connection of E/A-Modul to CAN-network, replace E/A-Modul
589950 E/A-Modul 5: Control data transfer CAN erroneous command test system X655:5/6 U-51.6/51.7 E 1
no reaction to unknown test system control command in CAN-System Software
check Software (test system)
592000 E/A-Modul 5: control engine long-term disruption E/A-Modul <-> accelerator crane op. cab E 1
engine in idle speed, after re-generation of the connection first idle speed
check LSB-connection ZE<>E/A-Modul, crane operators cab accelerator or connection to ZE (test system)
592001 E/A-Modul 5: control engine long-term disruption E/A-Modul <-> engine control E 1
engine control and E/A-Modul at emergency speed
engine control and E/A-Modul, check CAN-bus-connections
592005 E/A-Modul 5: control engine condition erroneous: CAN-signal engine ON <-> load ctrl. D+ OFF E 1
identification engine ON/OFF possibly erronous
check alternator line connection to display unit, check alternator signal
592006 E/A-Modul 5: control engine condition erroneous: CAN-signal engine OFF <-> load ctrl. D+ ON E 1
identification engine ON/OFF possibly erronous
check alternator line connection to display unit, check alternator signal
002389508 208
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
592036 E/A-Modul 5: control engine tacograph speed signal <-> gear output implausibel E 1
Tempomat/Temposet-function blocked, engine will be limited in the torque output
Tacograph connection <>E/A-Modul, signals to inputs from E/A-Modul, check gear speed; replace E/A-Modul Taco
592121 E/A-Modul 5: control transmission shift selector-specified gear range/travel direction erroneous E 1
travel switch signals will be switched off, emergency operation
check CAN-bus system, Check Software in E/A-Modules (test system)
592957 E/A-Modul 5: control brakes/pneumatic system brake pressure switch 0.5 bar signal "op. brakes active" missing E 1
operation brake signal activated if circle 1+2 > 1,5 bar, stronger application of the brake necessary
check connection from brake pressure switch to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593160 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 1 missing E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593161 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 2 missing E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593162 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 3 missing E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593165 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 1 short to supply voltage E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593166 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 2 short to supply voltage E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593167 E/A-Modul 5: instruments operators cab auxiliary brakes signal level 3 short to supply voltage E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
002389508 209
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
593175 E/A-Modul 5: instruments operators cab Tempomat lever no signal or supply voltage missing E 1
auxiliary brake(s) is/are not actuated
check connection from brake lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593176 E/A-Modul 5: instruments operators cab Tempomat lever signal SET+ no signal or short to ground E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593177 E/A-Modul 5: instruments operators cab Tempomat lever signal SET- no signal or short to ground E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593178 E/A-Modul 5: instruments operators cab Tempomat lever signal OFF no signal or short to ground E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593179 E/A-Modul 5: instruments operators cab Tempomat lever signal QUIT short to supply voltage E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593180 E/A-Modul 5: instruments operators cab Tempomat lever signal TEMPOSET short to supply voltage E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593181 E/A-Modul 5: instruments operators cab Tempomat lever signal TEMPOMAT SET+ without returning (QUIT) E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593182 E/A-Modul 5: instruments operators cab Tempomat lever signal TEMPOMAT SET- without returning (QUIT) E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593183 E/A-Modul 5: instruments operators cab Tempomat lever signal OFF without returning (QUIT) E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
593184 E/A-Modul 5: instruments operators cab Tempomat lever signals SET+, SET-, OFF erroneous combination E 1
Tempomat/Temposet-functions blocked
check connection from Tempomat lever to E/A-Modul, check signals to entries from E/A-Modul, replace E/A-Modul
002389508 210
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
595074 E/A-Modul 5: operation engine accelerator operators cab blocked in upper-carriage operation mode B
595075 E/A-Modul 5: operation engine accelerator operators cab blocked in support operation mode B
595076 E/A-Modul 5: operation engine accelerator op. cab blocked when auxiliary brake active or selected B
595077 E/A-Modul 5: operation engine accelerator upper-carr. activated on malf. of GAS <-> E/A-Modul B
596885 E/A-Modul 5: operation instruments operators cab Tempomat lever blocked in upper-carriage operation mode B
002389508 211
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
596886 E/A-Modul 5: operation instruments operators cab Tempomat lever blocked in support operation mode B
687252 E/A-Modul 6: Control data transfer LSB-B has recognised Bus collisions, communication interrupted X663:4/6 E 0
entry in error memory, driver draws itself back from bus, possible release of reset and re-booting of network
with temporary malfunctions error will be eliminated from system itself, otherwise check address assignment of sensor
687255 E/A-Modul 6: Control data transfer LSB-B Bus connection faulty/defect, short circuit to supply voltage X663:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
687256 E/A-Modul 6: Control data transfer LSB-B Bus connection faulty/defect, no supply/short circuit to earth X663:4/6 E 2
entry in error memory, driver tries permanently to re-boot bus, bus boots as soon as error is eliminated
check bus line, sensor (withdraw) and bus circuit board for shorts, check bus fuse on bus circuit board
687257 E/A-Modul 6: Control data transfer LSB-B has recognised network re-set (data transfer starts again) X663:4/6 E 1
entry in error memory, driver re-starts and runs re-booting of network
check bus lines, withdraw sensors successively from bus until malfunction source recognised, replace defective part
687258 E/A-Modul 6: Control data transfer LSB-B recognised participant with incorrect baud rate in bus X663:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated from system itself, check address assignment of sensors
687259 E/A-Modul 6: Control data transfer LSB-B recognised communication breakdown in bus X663:4/6 E 0
entry in error memory, driver re-starts and runs re-booting of network
will be eliminated by driver through re-booting of network
687260 E/A-Modul 6: Control data transfer LSB-B driver error: no order to carry out X663:4/6 E 2
entry in error memory, driver runs on normally and waits for bus connection of participant
with temporary malfunctions error will be eliminated by system itself, with incorrect configuration install new software
687261 E/A-Modul 6: Control data transfer LSB-B driver error: undefined message appears X663:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
with temporary malf. error will be eliminated by system itself otherwise new Software necessary for error elimination
687262 E/A-Modul 6: Control data transfer LSB-B driver error: initialising error X663:4/6 E 2
entry in error memory, driver re-starts and runs re-booting of network
new Software is necessary for error elimination
002389508 212
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
810162 ABV: CAN-bus system Speed signal Tachograph to CAN faulty/missing/implausible X94:1/2/3 U-93.7/93.8/93.6 E 1
ABV function not restricted
check CAN-network, ABV-control device, speed signal C3, E/A-Modul 5
810167 ABV: CAN-bus system CAN-communication gears faulty/not present X94:1/2/3 U-93.7/93.8/93.6 E 0
ABV function not restricted
check CAN-network, check/replace ABV-control device
810168 ABV: CAN-bus system CAN-communication engine or E/A-Modul 5 faulty/not present X94:1/2/3 U-93.7/93.8/93.6 E 0
ABV function not restricted
check CAN-network, check/replace ABV-control device
810169 ABV: CAN-bus system CAN-communication E/A-Modul 2 faulty/not present X94:1/2/3 U-93.7/93.8/93.6 E 0
ABV function not restricted
check CAN-network, check/replace ABV-control device
811001 ABV: control device error or power supply Kl.15/30 excess voltage X94:7/9 U-93.3/93.2 E 1
ABS: inactive
check net supply control device
811002 ABV: control device error or power supply Kl.15/30 voltage below required value X94:7/9 U-93.3/93.2 E 1
ABS: inactive
check net supply control device
811010 ABV: control device error or power supply Kl.15/30 defect X94:7/9 U-93.3/93.2 E 1
ABS: inactive, ASR: inactive
replace control device
811012 ABV: control device error or power supply Kl.15/30 incorrect parameters X94:7/9 U-93.3/93.2 E 1
ABS: inactive, ASR: inactive
replace control device
002389508 213
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
811029 ABV: control device error or power supply Kl.15/30 monitor switch time for solenoid valve actuated X94:7/9 U-93.3/93.2 E 0
ABS: inactive, ASR: inactive
check solenoid valve, control device
811094 ABV: control device error or power supply Kl.15/30 Wheel speeds/tyre dimensions implausible, incorrect parameterisation X94:7/9 U-93.3/93.2 E 1
ABS: wheel not regulated, ASR: inactive
check tires, magnet wheels, sensors
811102 ABV: control device error or power supply Kl.15/30 voltage below required value X94:7/9 U-93.3/93.2 E 1
ABS: inactive
check net supply control device
811103 ABV: control device error or power supply Kl.15/30 interruption X94:7/9 U-93.3/93.2 E 1
ABS: inactive
check net supply control device
811202 ABV: control device error or power supply Kl.15/30 voltage below required value X94:7/9 U-93.3/93.2 E 1
ABS: inactive
check net supply control device
811203 ABV: control device error or power supply Kl.15/30 interruption X94:7/9 U-93.3/93.2 E 1
ABS: inactive
check net supply control device
811602 ABV: control device error, power supply Kl.31 voltage below required value X94:10/12 U-93.4/93.5 E 1
ABS: inactive
check net supply control device
811609 ABV: control device error, power supply Kl.31 interruption X94:10/12 U-93.4/93.5 E 1
ABS: inactive
check net supply control device
811702 ABV: control device error, power supply Kl.31 voltage below required value X94:10/12 U-93.4/93.5 E 1
ABS: inactive
check net supply control device
811709 ABV: control device error, power supply Kl.31 interruption X94:10/12 U-93.4/93.5 E 1
ABS: inactive
check net supply control device
002389508 214
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
813020 ABV: ABS-solenoid valve front axle right interruption X96:7/8/9 U-94.4/94.3/94.3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813021 ABV: ABS-solenoid valve front axle right short circuit to ground X96:7/8/9 U-94.4/94.3/94.3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813022 ABV: ABS-solenoid valve front axle right short circuit to supply voltage X96:7/8/9 U-94.4/94.3/94.3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813023 ABV: ABS-solenoid valve front axle right interruption X96:7/8/9 U-94.4/94.3/94.3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
002389508 215
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
813026 ABV: ABS-solenoid valve front axle right interruption X96:7/8/9 U-94.4/94.3/94.3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813027 ABV: ABS-solenoid valve front axle right short circuit to ground X96:7/8/9 U-94.4/94.3/94.3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813028 ABV: ABS-solenoid valve front axle right short circuit to supply voltage X96:7/8/9 U-94.4/94.3/94.3 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813030 ABV: ABS-solenoid valve front axle right external control X96:7/8/9 U-94.4/94.3/94.3 E 2
ABS: front/rear diagonal and differential brakes inactive
check cabling, valve (ohm resistance), control device
813120 ABV: ABS-solenoid valve front axle left interruption X95:1/2/3 U-94.2/94.1/94.1 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813121 ABV: ABS-solenoid valve front axle left short circuit to ground X95:1/2/3 U-94.2/94.1/94.1 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813122 ABV: ABS-solenoid valve front axle left short circuit to supply voltage X95:1/2/3 U-94.2/94.1/94.1 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813123 ABV: ABS-solenoid valve front axle left interruption X95:1/2/3 U-94.2/94.1/94.1 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813126 ABV: ABS-solenoid valve front axle left interruption X95:1/2/3 U-94.2/94.1/94.1 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813127 ABV: ABS-solenoid valve front axle left short circuit to ground X95:1/2/3 U-94.2/94.1/94.1 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
002389508 216
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
813128 ABV: ABS-solenoid valve front axle left short circuit to supply voltage X95:1/2/3 U-94.2/94.1/94.1 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813130 ABV: ABS-solenoid valve front axle left external control X95:1/2/3 U-94.2/94.1/94.1 E 2
ABS: front/rear diagonal and differential brakes inactive
check cabling, valve (ohm resistance), control device
813220 ABV: ABS-solenoid valve rear axle right interruption X97:10/11/12 U-94.7/94.6/94.6 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813221 ABV: ABS-solenoid valve rear axle right short circuit to ground X97:10/11/12 U-94.7/94.6/94.6 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813222 ABV: ABS-solenoid valve rear axle right short circuit to supply voltage X97:10/11/12 U-94.7/94.6/94.6 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813223 ABV: ABS-solenoid valve rear axle right interruption X97:10/11/12 U-94.7/94.6/94.6 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813226 ABV: ABS-solenoid valve rear axle right interruption X97:10/11/12 U-94.7/94.6/94.6 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813227 ABV: ABS-solenoid valve rear axle right short circuit to ground X97:10/11/12 U-94.7/94.6/94.6 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813228 ABV: ABS-solenoid valve rear axle right short circuit to supply voltage X97:10/11/12 U-94.7/94.6/94.6 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813230 ABV: ABS-solenoid valve rear axle right external control X97:10/11/12 U-94.7/94.6/94.6 E 2
ABS: front/rear diagonal and differential brakes inactive
check cabling, valve (ohm resistance), control device
002389508 217
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
813320 ABV: ABS-solenoid valve rear axle left interruption X97:1/2/3 U-94.5/94.4/94.4 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813321 ABV: ABS-solenoid valve rear axle left short circuit to ground X97:1/2/3 U-94.5/94.4/94.4 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813322 ABV: ABS-solenoid valve rear axle left short circuit to supply voltage X97:1/2/3 U-94.5/94.4/94.4 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813323 ABV: ABS-solenoid valve rear axle left interruption X97:1/2/3 U-94.5/94.4/94.4 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813326 ABV: ABS-solenoid valve rear axle left interruption X97:1/2/3 U-94.5/94.4/94.4 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813327 ABV: ABS-solenoid valve rear axle left short circuit to ground X97:1/2/3 U-94.5/94.4/94.4 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813328 ABV: ABS-solenoid valve rear axle left short circuit to supply voltage X97:1/2/3 U-94.5/94.4/94.4 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813330 ABV: ABS-solenoid valve rear axle left external control X97:1/2/3 U-94.5/94.4/94.4 E 2
ABS: front/rear diagonal and differential brakes inactive
check cabling, valve (ohm resistance), control device
813604 ABV: valve front axle right and rear axle left short circuit to ground X96/X97 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813605 ABV: valve front axle right and rear axle left short circuit to supply voltage X96/X97 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
002389508 218
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
813704 ABV: valve front axle left and rear axle right short circuit to ground X96/X98 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813705 ABV: valve front axle left and rear axle right short circuit to supply voltage X96/X98 E 1
ABS: wheel not regulated
check cabling, valve (ohm resistance), control device
813805 ABV: ASR, DIF-valve short circuit to supply voltage X97:4/7 U-94.8/94.8 E 1
ASR: inactive
check cabling, valve (ohm resistance), control device
814040 ABV: speed sensor front axle right interruption X96:4/5 U-93.3/93.4 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814041 ABV: speed sensor front axle right short circuit to ground X96:4/5 U-93.3/93.4 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814042 ABV: speed sensor front axle right short circuit to supply voltage X96:4/5 U-93.3/93.4 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814044 ABV: speed sensor front axle right winding short X96:4/5 U-93.3/93.4 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
002389508 219
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
814045 ABV: speed sensor front axle right magnet wheel defect X96:4/5 U-93.3/93.4 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel
814046 ABV: speed sensor front axle right sensor vibration X96:4/5 U-93.3/93.4 E 0
ABS: partly inactive, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel
814047 ABV: speed sensor front axle right shimmed magnet wheel X96:4/5 U-93.3/93.4 E 0
814048 ABV: speed sensor front axle right Air gap, clearance sensor<>magnet wheel too large X96:4/5 U-93.3/93.4 E 1
ABS: wheel not regulated, ASR: inactive
check play in wheel bearing, sensor voltage, ohm resistance of cabling; push sensor on magnet wheel
814140 ABV: speed sensor front axle left interruption X95:4/5 U-93.1/93.2 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814141 ABV: speed sensor front axle left short circuit to ground X95:4/5 U-93.1/93.2 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814142 ABV: speed sensor front axle left short circuit to supply voltage X95:4/5 U-93.1/93.2 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814144 ABV: speed sensor front axle left winding short X95:4/5 U-93.1/93.2 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814145 ABV: speed sensor front axle left magnet wheel defect X95:4/5 U-93.1/93.2 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel
814146 ABV: speed sensor front axle left sensor vibration X95:4/5 U-93.1/93.2 E 0
ABS: partly inactive, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel
002389508 220
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
814147 ABV: speed sensor front axle left shimmed magnet wheel X95:4/5 U-93.1/93.2 E 0
814148 ABV: speed sensor front axle left Air gap, clearance sensor<>magnet wheel too large X95:4/5 U-93.1/93.2 E 1
ABS: wheel not regulated, ASR: inactive
check play in wheel bearing, sensor voltage, ohm resistance of cabling; push sensor on magnet wheel
814240 ABV: speed sensor rear axle right interruption X97:8/9 U-93.7/93.7 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814241 ABV: speed sensor rear axle right short circuit to ground X97:8/9 U-93.7/93.7 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814242 ABV: speed sensor rear axle right short circuit to supply voltage X97:8/9 U-93.7/93.7 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814244 ABV: speed sensor rear axle right winding short X97:8/9 U-93.7/93.7 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814245 ABV: speed sensor rear axle right magnet wheel defect X97:8/9 U-93.7/93.7 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel
814246 ABV: speed sensor rear axle right sensor vibration X97:8/9 U-93.7/93.7 E 0
ABS: partly inactive, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel
814247 ABV: speed sensor rear axle right shimmed magnet wheel X97:8/9 U-93.7/93.7 E 0
814248 ABV: speed sensor rear axle right Air gap, clearance sensor<>magnet wheel too large X97:8/9 U-93.7/93.7 E 1
ABS: wheel not regulated, ASR: inactive
check play in wheel bearing, sensor voltage, ohm resistance of cabling; push sensor on magnet wheel
002389508 221
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
814340 ABV: speed sensor rear axle left interruption X97:5/6 U-93.5/93.6 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814341 ABV: speed sensor rear axle left short circuit to ground X97:5/6 U-93.5/93.6 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814342 ABV: speed sensor rear axle left short circuit to supply voltage X97:5/6 U-93.5/93.6 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814344 ABV: speed sensor rear axle left winding short X97:5/6 U-93.5/93.6 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling
814345 ABV: speed sensor rear axle left magnet wheel defect X97:5/6 U-93.5/93.6 E 1
ABS: wheel not regulated, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel
814346 ABV: speed sensor rear axle left sensor vibration X97:5/6 U-93.5/93.6 E 0
ABS: partly inactive, ASR: inactive
check sensor voltage, Ohm resistance of cabling, magnet wheel
814347 ABV: speed sensor rear axle left shimmed magnet wheel X97:5/6 U-93.5/93.6 E 0
814348 ABV: speed sensor rear axle left Air gap, clearance sensor<>magnet wheel too large X97:5/6 U-93.5/93.6 E 1
ABS: wheel not regulated, ASR: inactive
check play in wheel bearing, sensor voltage, ohm resistance of cabling; push sensor on magnet wheel
002389508 222
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
843305 heating, air cond.: WEBASTO THERMO 90 S glow probe interruption/short circuit E 1
error report and feedback " supplementary heating ON" flashing on display unit (5x short, 5x long)
check cabling for damage, search for break and short, replace flame detector
843306 heating, air cond.: WEBASTO THERMO 90 S temperature probe interruption/short circuit E 1
error report and feedback " supplementary heating ON" flashing on display unit (5x short, 6x long)
check cabling for damage, search for break and short, replace temperature sensor
843307 heating, air cond.: WEBASTO THERMO 90 S metering pump/solenoid valve interruption/short circuit E 1
error report and feedback " supplementary heating ON" flashing on display unit (5x short, 7x long)
check coolant level, bleed coolant circuit, reset temperature limitation, examine cabling
843308 heating, air cond.: WEBASTO THERMO 90 S blower motor interruption/short circuit/erroneous speed E 1
error report and feedback " supplementary heating ON" flashing on display unit (5x short, 8x long)
check cabling for damage, search for break and short, replace combustion air ventilator
843309 heating, air cond.: WEBASTO THERMO 90 S glow pin interruption/short circuit E 1
error report and feedback " supplementary heating ON" flashing on display unit (5x short, 9x long)
check cabling for damage, search for break and short, replace heater plug
843311 heating, air cond.: WEBASTO THERMO 90 S water pump interruption/short circuit E 1
error report and feedback "supplementary heating ON" flashing on display unit (5x short, 11x long)
check cabling for damage, search for break and short, replace water pump
002389508 223
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
843312 heating, air cond.: WEBASTO THERMO 90 S set value sensor interruption/short circuit E 1
error report and acknowledgement " supplementary heating ON" flashing on display unit (5x short, 12x long)
check cabling for damage, search for break and short, replace set value transmitter
920106 engine V6: control device engine Data communication CAN faulty / interrupted X275:1/4/7 U-51.4/51.4/51.5 E 1
emergency operation
check cable/plugs for shorts
920107 engine V6: control device engine Data communication CAN cancelled X275:1/4/7 U-51.4/51.4/51.5 E 1
emergency operation
check cable/plugs for UB- or shorts to ground
920208 engine V6: CAN-participant ABV (ABS/ASR) Data transfer faulty/missing, max. cycle time exceeded X275:1/4/7 U-51.4/51.4/51.5 E 1
limited function
check cable/plugs/ABS-/ASR-electronics
920308 engine V6: CAN-participant gear Data transfer faulty/missing, max. cycle time exceeded X275:1/4/7 U-51.4/51.4/51.5 E 1
limited function
check cable/plugs/gear electronics
920408 engine V6: CAN-participant E/A-Modul Data transfer faulty/missing, max. cycle time exceeded X275:1/4/7 U-51.4/51.4/51.5 E 1
emergency operation
check cable/plugs/E/A-Modul(e)
920508 engine V6: CAN signals gear Data transfer faulty/missing, max. cycle time exceeded X275:1/4/7 U-51.4/51.4/51.5 E 1
limited function
check cable/plugs/gear electronics
920608 engine V6: CAN signals travel switch Data transfer faulty/missing, max. cycle time exceeded X275:1/4/7 U-51.4/51.4/51.5 E 1
limited function
check cable/plugs/E/A-Modul(e)
002389508 224
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
920910 engine V6: speed 1/2 inadmissable signal difference/plausability control defective X273:18/19/20/2 U-55.3/55.1/55.2/55. E 1
switch-over to other speed sensor or engine-stop 1 4
check cable/plugs/sensor, distance to flywheel
921002 engine V6: accelerator 1 sensor defect high/short circ. to supply voltage X274:16/17 U-54.3/54.4 E 1
switch-over to accelerator 2,speed limitation, torque limitation or 20-23
check cable/plugs for UB-shorts
921003 engine V6: accelerator 1 sensor defect low/short circuit to ground X274:16/17 U-54.3/54.4 E 1
switch-over to accelerator 2,speed limitation, torque limitation or 20-23
check cable/plugs for breaks or short to ground
921102 engine V6: accelerator 2 sensor defect high/short circ. to supply voltage X274:14/15 U-54.1/54.2 E 1
switch-over to accelerator 1, speed limitation, torque limitation or emergency operation at error code 16-19
check cable/plugs for UB-shorts
921103 engine V6: accelerator 2 sensor defect low/short circuit to ground X274:14/15 U-54.1/54.2 E 1
switch-over to accelerator 1, speed limitation, torque limitation or emergency operation at error code 16-19
check cable/plugs for breaks or short to ground
002389508 225
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
921210 engine V6: accelerator 1/2 inadmissable signal difference/plausability control defective X274:14/15/16/1 U-54.1/54.2/54.3/54. E 1
gas withdrawal (idle) 7 4
check pedal unit, check condition of operation brake
921611 engine V6: trigger signal box EDC excess current recognition X271:7/10 U-54.5/54.5 E 1
engine-Stop
check cable/plugs, replace LH-ECU1, check EDC-actuator, if necessary replace injector pump
921701 engine V6: signal box feedback EDC unit defect X271:13/14/15 U-54.8/54.6/54.7 E 1
engine-Stop
check cable/plugs, replace LH-ECU1, check EDC-actuator, if necessary replace injector pump
921814 engine V6: alternator D+ short circuit to supply voltage X273:14 U-52.4 E 1
signal ignored
check cable/plugs for UB-shorts
921917 engine V6: supply KL30 voltage below required value X272:1 U-53.2 E 1
generate error report; Reset: automatic after error counter sequence or regulator reset
check main circuit voltage, check battery
922012 engine V6: start engine KL50 short circuit to ground X274:13 U-53.1 E 1
generate error report; Reset: automatic after error counter sequence or regulator reset
check cable/plugs for short to ground
922112 engine V6: DA, flame type heater plugs diagnosis short circuit to ground X271:9 U-57.7 E 1
error report
check cable/plugs for short to ground, replace Relaismodul
002389508 226
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
922113 engine V6: DA, flame type heater plugs diagnosis open signal circuits X271:9 U-57.7 E 1
shut off FGK and MVE
check cable/plugs for breaks, replace Relaismodul
922114 engine V6: DA, flame type heater plugs diagnosis short circuit to supply voltage X271:9 U-57.7 E 1
error report
check cable/plugs for UB-shorts, replace Relaismodul
922512 engine V6: Speed signal tachograph short circuit to ground X275:9 E 1
Signal is ignored, switch off of functions TMAT/TSET, reduction of maximum moment due to Vset
Check or replace line connection tachograph<->ECU, tachograph, ECU
922513 engine V6: Speed signal tachograph open signal circuits X275:9 E 1
Signal is ignored, switch off of functions TMAT/TSET, reduction of maximum moment due to Vset
Check or replace line connection tachograph<->ECU, tachograph, ECU
922514 engine V6: Speed signal tachograph short circuit to supply voltage X275:9 E 1
Signal is ignored, switch off of functions TMAT/TSET, reduction of maximum moment due to Vset
Check or replace line connection tachograph<->ECU, tachograph, ECU
922602 engine V6: oil pressure sensor sensor defect high/short circ. to supply voltage X273:1/2/3 U-56.1/56.2/56.3 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor
002389508 227
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
922603 engine V6: oil pressure sensor sensor defect low/short circuit to ground X273:1/2/3 U-56.1/56.2/56.3 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor
922702 engine V6: charge air pressure sensor sensor defect high/short circ. to supply voltage X273:4/5/6 U-55.6/55.7/55.8 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor
922703 engine V6: charge air pressure sensor sensor defect low/short circuit to ground X273:4/5/6 U-55.6/55.7/55.8 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor
922802 engine V6: air filter sensor sensor defect high/short circ. to supply voltage X273:7/8/9 U-57.1/57.3/57.2 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor
922803 engine V6: air filter sensor sensor defect low/short circuit to ground X273:7/8/9 U-57.1/57.3/57.2 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor
923102 engine V6: charge air temperature sensor sensor defect high/short circ. to supply voltage X273:12/15 U-55.4/55.5 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor
923103 engine V6: charge air temperature sensor sensor defect low/short circuit to ground X273:12/15 U-55.4/55.5 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor
923202 engine V6: coolant temperature sensor sensor defect high/short circ. to supply voltage X273:10/11 U-56.7/56.8 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor
923203 engine V6: coolant temperature sensor sensor defect low/short circuit to ground X273:10/11 U-56.7/56.8 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor
923313 engine V6: coolant level sensor open signal circuits X274:10/11 U-56.6/56.6 E 1
signal ignored, substitute value used
check cable/plugs for defects or breaks, replace sensor
002389508 228
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
923402 engine V6: oil temperature sensor sensor defect high/short circ. to supply voltage X273:16/17 U-56.4/56.4 E 1
signal ignored, substitute value used
check cable/plugs for shorts to ground, replace sensor
923403 engine V6: oil temperature sensor sensor defect low/short circuit to ground X273:16/17 U-56.4/56.4 E 1
signal ignored, substitute value used
check cable/plugs for UB-shorts, replace sensor
923512 engine V6: Sensor jib-movement-detector (NBF) short circuit to ground X271:1/2 E 1
Change-over to power-regulated operation
Check line connection ECU<->NBF sensor, NBV sensor; Replace NBF sensor
923513 engine V6: Sensor jib-movement-detector (NBF) open signal circuits X271:1/2 E 1
Change-over to power-regulated operation
Check line connection ECU<->NBF sensor, NBV sensor; Replace NBF sensor
923514 engine V6: Sensor jib-movement-detector (NBF) short circuit to supply voltage X271:1/2 E 1
Change-over to power-regulated operation
Check line connection ECU<->NBF sensor, NBV sensor; Replace NBF sensor
923601 engine V6: trigger flame type heater plug(s) FGK unit defect X271:4 U-57.5 E 1
shut off FGK and MVE
check cable/plugs for defects or breaks, check FGK, replace Relaismodul
923614 engine V6: trigger flame type heater plug(s) FGK short circuit to supply voltage X271:4 U-57.5 E 1
923615 engine V6: trigger flame type heater plug(s) FGK open electric circuit X271:4 U-57.5 E 1
error report
check cable/plugs for breaks, replace Relaismodul
923618 engine V6: trigger flame type heater plug(s) FGK excess temperature X271:4 U-57.5 E 1
shut off FGK and MVE
check cable/plugs for short to ground, replace Relaismodul
923714 engine V6: solenoid valve additional flow for starting short circuit to supply voltage X271:6 U-57.6 E 1
002389508 229
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
923715 engine V6: solenoid valve additional flow for starting open electric circuit X271:6 U-57.6 E 1
FSA data defective, FGK activation removed, MVE reset: automatic after error counter sequence, after regulator reset
923718 engine V6: solenoid valve additional flow for starting excess temperature X271:6 U-57.6 E 1
shut off FGK and MVE
check cable/plugs for short to ground, replace Relaismodul
923814 engine V6: engine start 50A short circuit to supply voltage X271:5 U-57.4 E 1
923815 engine V6: engine start 50A open electric circuit X271:5 U-57.4 E 1
starting procedure interrupted, shut down FGK and MVE
check cable/plugs for breaks, replace Relaismodul
923818 engine V6: engine start 50A excess temperature X271:5 U-57.4 E 1
starting procedure interrupted, shut down FGK and MVE
check cable/plugs for short to ground, replace Relaismodul
002389508 230
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
924504 engine V6: Calculation spray begin (SB) level exceeded X271 E 1
Change-over to controlled injection-start operation (SB)
924505 engine V6: Calculation spray begin (SB) below minimum level X271 E 1
Change-over to controlled injection-start operation (SB)
924526 engine V6: Calculation spray begin (SB) No synchronisation possible X271 E 1
Change-over to controlled injection-start operation (SB)
Checking of OT signal transmitter and NBF
926124 engine V6: charge air temperature pre-warning disruption limit 1 X273:12/15 U-55.4/55.5 E 1
warning, engine-protection-info, output reduction
reduce output, check air suction routing and engine
926125 engine V6: charge air temperature pre-warning disruption limit 2 X273:12/15 U-55.4/55.5 E 1
warning, engine-protection-info, output reduction
reduce output, if necessary shut off engine, check air suction routing and engine
926224 engine V6: coolant temperature pre-warning disruption limit 1 X273:10/11 U-56.7/56.8 E 1
warning, engine-protection-info, output reduction
reduce output, check coolant level and engine
926225 engine V6: coolant temperature pre-warning disruption limit 2 X273:10/11 U-56.7/56.8 E 1
warning, engine-protection-info, output reduction
reduce output, if necessary shut off engine, check coolant level and engine
926324 engine V6: coolant level pre-warning disruption limit 1 X274:11/12 U-56.6/55.6 E 1
warning
shut off engine, check coolant level and if necessary replenish, check for leaks
926424 engine V6: oil pressure pre-warning disruption limit 1 X273:1/2/3 U-56.1/56.2/56.3 E 1
warning
shut off engine, check oil level and if necessary replenish, check for leaks
002389508 231
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
926522 engine V6: air filter pressure pre-warning disruption limit 1 X273:7/8/9 U-57.1/57.3/57.2 E 1
pre-warning
replace air filter at next opportunity
926525 engine V6: air filter pressure pre-warning disruption limit 2 X273:7/8/9 U-57.1/57.3/57.2 E 1
warning
replace air filter immediately
926624 engine V6: v-belt break pre-warning disruption limit 1 X273:14 U-52.4 E 1
warning
replace V-belts, check generator and replace if necessary
926824 engine V6: charge air pressure pre-warning disruption limit 1 X273:4/5/6 U-55.6/55.7/55.8 E 1
signal ignored, substitute value will be used, error report
check air suction routing
926825 engine V6: charge air pressure pre-warning disruption limit 2 X273:4/5/6 U-55.6/55.7/55.8 E 1
signal ignored, substitute value will be used, error report
check air suction routing
926924 engine V6: oil temperature pre-warning disruption limit 1 X273:16/17 U-56.4/56.4 E 1
signal ignored, substitute value will be used, error report
check oil level/oil circulation
926925 engine V6: oil temperature pre-warning disruption limit 2 X273:16/17 U-56.4/56.4 E 1
signal ignored, substitute value will be used, error report
check oil level/oil circulation
928250 engine V6: change engine oil filter service report interval 1 attained/exceeded X27 E 1
report
check and return
002389508 232
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
928350 engine V6: change engine oil service report interval 1 attained/exceeded X27 E 1
report
change oil and return
928351 engine V6: change engine oil service report interval 2 attained/exceeded X27 E 1
report
change oil and return
928352 engine V6: change engine oil service report interval 3 attained/exceeded X27 E 1
report
change oil and return
928353 engine V6: change engine oil service report interval 4 attained/exceeded X27 E 1
report
change oil and return
928354 engine V6: change engine oil service report interval 5 attained/exceeded X27 E 1
report
change oil and return
928355 engine V6: change engine oil service report interval 6 attained/exceeded X27 E 1
report
change oil and return
928356 engine V6: change engine oil service report interval 7 attained/exceeded X27 E 1
report
change oil and return
928357 engine V6: change engine oil service report interval 8 attained/exceeded X27 E 1
report
change oil and return
928358 engine V6: change engine oil service report interval 9 attained/exceeded X27 E 1
report
change oil and return
928359 engine V6: change engine oil service report interval 10 attained/exceeded X27 E 1
report
change oil and return
002389508 233
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
928650 engine V6: check battery service report interval 1 attained/exceeded X27 E 1
report
check and return
928750 engine V6: change water filter service report interval 1 attained/exceeded X27 E 1
report
change filter and return
928850 engine V6: check antifreeze service report interval 1 attained/exceeded X27 E 1
report
check and return
928950 engine V6: fuel filter level 1 service report interval 1 attained/exceeded X27 E 1
report
change filter and return
929050 engine V6: fuel filter level 2 service report interval 1 attained/exceeded X27 E 1
report
change filter and return
929150 engine V6: valve clearance service report interval 1 attained/exceeded X27 E 1
report
check and return
929250 engine V6: fuel injection valves service report interval 1 attained/exceeded X27 E 1
report
check and return
960111 gear 6 WG 260: TCU output AIP1 gear clutch K1 excess current recognition X45:56/12/13 U-65.1/65.6/65.7 E 1
002389508 234
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
960112 gear 6 WG 260: TCU output AIP1 gear clutch K1 short circuit to ground X45:56/12/13 U-65.1/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears
960114 gear 6 WG 260: TCU output AIP1 gear clutch K1 short circuit to supply voltage X45:56/12/13 U-65.1/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears
960115 gear 6 WG 260: TCU output AIP1 gear clutch K1 open electric circuit X45:56/12/13 U-65.1/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears
960211 gear 6 WG 260: TCU output AIP2 gear clutch K2 excess current recognition X45:10/12/13 U-65.2/65.6/65.7 E 1
960212 gear 6 WG 260: TCU output AIP2 gear clutch K2 short circuit to ground X45:10/12/13 U-65.2/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears
960214 gear 6 WG 260: TCU output AIP2 gear clutch K2 short circuit to supply voltage X45:10/12/13 U-65.2/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears
960215 gear 6 WG 260: TCU output AIP2 gear clutch K2 open electric circuit X45:10/12/13 U-65.2/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears
960311 gear 6 WG 260: TCU output AIP3 gear clutch K3 excess current recognition X45:32/12/13 U-65.3/65.6/65.7 E 1
960312 gear 6 WG 260: TCU output AIP3 gear clutch K3 short circuit to ground X45:32/12/13 U-65.3/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears
960314 gear 6 WG 260: TCU output AIP3 gear clutch K3 short circuit to supply voltage X45:32/12/13 U-65.3/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears
002389508 235
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
960315 gear 6 WG 260: TCU output AIP3 gear clutch K3 open electric circuit X45:32/12/13 U-65.3/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears
960411 gear 6 WG 260: TCU output AIP4 gear clutch K4 excess current recognition X45:55/12/13 U-65.4/65.6/65.7 E 1
960412 gear 6 WG 260: TCU output AIP4 gear clutch K4 short circuit to ground X45:55/12/13 U-65.4/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears
960414 gear 6 WG 260: TCU output AIP4 gear clutch K4 short circuit to supply voltage X45:55/12/13 U-65.4/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears
960415 gear 6 WG 260: TCU output AIP4 gear clutch K4 open electric circuit X45:55/12/13 U-65.4/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears
960511 gear 6 WG 260: TCU output AIP5 gear clutch KV excess current recognition X45:9/12/13 U-65.4/65.6/65.7 E 1
960512 gear 6 WG 260: TCU output AIP5 gear clutch KV short circuit to ground X45:9/12/13 U-65.4/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears
960514 gear 6 WG 260: TCU output AIP5 gear clutch KV short circuit to supply voltage X45:9/12/13 U-65.4/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears
960515 gear 6 WG 260: TCU output AIP5 gear clutch KV open electric circuit X45:9/12/13 U-65.4/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears
960611 gear 6 WG 260: TCU output AIP6 gear clutch KR excess current recognition X45:51/12/13 U-65.5/65.6/65.7 E 1
002389508 236
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
960612 gear 6 WG 260: TCU output AIP6 gear clutch KR short circuit to ground X45:51/12/13 U-65.5/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears
960614 gear 6 WG 260: TCU output AIP6 gear clutch KR short circuit to supply voltage X45:51/12/13 U-65.5/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears
960615 gear 6 WG 260: TCU output AIP6 gear clutch KR open electric circuit X45:51/12/13 U-65.5/65.6/65.7 E 1
TCU switches to "N", emergency function, on malfunction of other couplings TCU switches to "N", TCU-shut-down
check cable TCU<>transmission, plug connections TCU, regulator resistance, internal cable set of gears
002389508 237
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
962711 gear 6 WG 260: TCU ADM7 transformer shunting clutch excess current recognition X45:34/8/53 U-64.6/64.7/64.8 E 1
962712 gear 6 WG 260: TCU ADM7 transformer shunting clutch short circuit to ground X45:34/8/53 U-64.6/64.7/64.8 E 1
no reaction; operation mode: normal
check cable TCU<>WK-magnet, connector plug WK-magnet<>TCU, resistance of WK-magnet
962714 gear 6 WG 260: TCU ADM7 transformer shunting clutch short circuit to supply voltage X45:34/8/53 U-64.6/64.7/64.8 E 1
no reaction; operation mode: normal
check cable TCU<>WK-magnet, connector plug WK-magnet<>TCU, resistance of WK-magnet
962715 gear 6 WG 260: TCU ADM7 transformer shunting clutch open electric circuit X45:34/8/53 U-64.6/64.7/64.8 E 1
transformer coupling constantly opened, retarder not available; operation mode: normal
check cable TCU<>WK-magnet, connector plug WK-magnet<>TCU, resistance of WK-magnet
963118 gear 6 WG 260: TCU input ER1 temperature sensor excess temperature X45:46/39 U-65.4/65.4 E 1
963157 gear 6 WG 260: TCU input ER1 temperature sensor open circuit or short circuit to supply voltage X45:46/39 U-65.4/65.4 E 1
no reaction, TCC uses substitute temperature; operation mode: normal
check cable from TCU<->sensor, check connector plug, check temperature sensor
963158 gear 6 WG 260: TCU input ER1 temperature sensor short circuit to ground X45:46/39 U-65.4/65.4 E 1
no reaction, TCC uses substitute temperature; operation mode: normal
check cable from TCU<->sensor, check connector plug, check temperature sensor
963218 gear 6 WG 260: TCU entry ER2 temperature sensor to converter excess temperature X45:49/46 E 1
963257 gear 6 WG 260: TCU entry ER2 temperature sensor to converter open circuit or short circuit to supply voltage X45:49/46 E 1
no reaction, TCC uses substitute temperature; operation mode: normal
check cable from TCU<->sensor, check connector plug, check temperature sensor
963258 gear 6 WG 260: TCU entry ER2 temperature sensor to converter short circuit to ground X45:49/46 E 1
no reaction, TCC uses substitute temperature; operation mode: normal
check cable from TCU<->sensor, check connector plug, check temperature sensor
002389508 238
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
963580 gear 6 WG 260: oil filter contamination sensor report filter exchange X45:17 E 1
possible transmission lubrication malfunction
check oil filter, oil circulation, check sensor
963812 gear 6 WG 260: TCU speed sensor supply VMG1 short circuit to ground X45:3 U-64.3 E 1
963814 gear 6 WG 260: TCU speed sensor supply VMG1 short circuit to supply voltage X45:3 U-64.3 E 1
963912 gear 6 WG 260: TCU speed sensor supply VMG2 short circuit to ground X45:4 U-64.5 E 1
963914 gear 6 WG 260: TCU speed sensor supply VMG2 short circuit to supply voltage X45:4 U-64.5 E 1
964012 gear 6 WG 260: TCU supply 30 VPE1 short circuit to ground X45:23 U-64.3 E 1
964112 gear 6 WG 260: TCU supply 30 VPE2 short circuit to ground X45:68 U-64.4 E 1
964212 gear 6 WG 260: TCU supply 15 VpI short circuit to ground X45:45 U-64.4 E 1
964312 gear 6 WG 260: TCU analogue sensor supply AU1/VMGA2 short circuit to ground X4546 E 1
no reaction, TCU uses substitute temperature; operation mode: normal
check cable/connector plug to sensors, which will be supplied from AU1, check power supply AU1 (about 5V)
964314 gear 6 WG 260: TCU analogue sensor supply AU1/VMGA2 short circuit to supply voltage X4546 E 1
no reaction, TCU uses substitute temperature; operation mode: normal
check cable/connector plug to sensors, which will be supplied from AU1, check power supply AU1 (about 5V)
002389508 239
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
964432 gear 6 WG 260: TCU valve coupling supply VPS1 error X45:12/13 U-65.6/65.7 E 1
switches to "N"; operation mode: TCU-shut-down
check cable from transmission to TCU, check connector plug from gears to TCU, replace TCU
964532 gear 6 WG 260: TCU valve coupling supply VPS2 error X45:8/53 U-64.7/64.8 E 1
switches to "N"; operation mode: TCU-shut-down
check cable from transmission to TCU, check connector plug from gears to TCU, replace TCU
964856 gear 6 WG 260: emergency drive switch supply open circuit or short circuit to ground X45:45 U-64.4 E 1
no emergency program with emergency drive switch possible
965412 gear 6 WG 260: TCU input 4 ED4 emergency drive switch D short circuit to ground X45:43 U-64.7 E 1
no emergency program with emergency drive switch possible
965413 gear 6 WG 260: TCU input 4 ED4 emergency drive switch D open signal circuits X45:43 U-64.7 E 1
no emergency program with emergency drive switch possible
965414 gear 6 WG 260: TCU input 4 ED4 emergency drive switch D short circuit to supply voltage X45:43 U-64.7 E 1
no emergency program with emergency drive switch possible
965512 gear 6 WG 260: TCU input 5 ED5 emergency drive switch R short circuit to ground X45:64 U-64.8 E 1
no emergency program with emergency drive switch possible
965513 gear 6 WG 260: TCU input 5 ED5 emergency drive switch R open signal circuits X45:64 U-64.8 E 1
no emergency program with emergency drive switch possible
965514 gear 6 WG 260: TCU input 5 ED5 emergency drive switch R short circuit to supply voltage X45:64 U-64.8 E 1
no emergency program with emergency drive switch possible
965612 gear 6 WG 260: TCU input 6 ED6 emergency drive switch N short circuit to ground X45:67 U-64.6 E 1
no emergency program with emergency drive switch possible
002389508 240
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
965613 gear 6 WG 260: TCU input 6 ED6 emergency drive switch N open signal circuits X45:67 U-64.6 E 1
no emergency program with emergency drive switch possible
965614 gear 6 WG 260: TCU input 6 ED6 emergency drive switch N short circuit to supply voltage X45:67 U-64.6 E 1
no emergency program with emergency drive switch possible
966712 gear 6 WG 260: TCU RS232 diagnosis SDDK short circuit to ground X45:15 U-65.7 E 1
diagnosis via test device not possible
966713 gear 6 WG 260: TCU RS232 diagnosis SDDK open signal circuits X45:15 U-65.7 E 1
diagnosis via test device not possible
966714 gear 6 WG 260: TCU RS232 diagnosis SDDK short circuit to supply voltage X45:15 U-65.7 E 1
diagnosis via test device not possible
966812 gear 6 WG 260: TCU RS232 diagnosis EUPR short circuit to ground X45:18 U-65.8 E 1
diagnosis via test device not possible
966813 gear 6 WG 260: TCU RS232 diagnosis EUPR open signal circuits X45:18 U-65.8 E 1
diagnosis via test device not possible
966814 gear 6 WG 260: TCU RS232 diagnosis EUPR short circuit to supply voltage X45:18 U-65.8 E 1
diagnosis via test device not possible
967008 gear 6 WG 260: CAN-communication transmission bus transmission exceeded X45:25/26 U-51.1/51.2 E 1
967106 gear 6 WG 260: CAN-communication LH motor permanent error bus connection X45:25/26 U-51.1/51.2 E 1
002389508 241
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
967107 gear 6 WG 260: CAN-communication LH motor maximum participant-transmission cycle exceeded X45:25/26 U-51.1/51.2 E 1
operation mode: control of emergency coupling
check engine control device, check line from CAN-bus, check cable to engine control device
967306 gear 6 WG 260: CAN-communication ABS/ASR permanent error bus connection X45:25/26 U-51.1/51.2 E 1
967307 gear 6 WG 260: CAN-communication ABS/ASR maximum participant-transmission cycle exceeded X45:25/26 U-51.1/51.2 E 1
967406 gear 6 WG 260: CAN-communication E/A-Modul 1 permanent error bus connection X45:25/26 U-51.1/51.2 E 1
967407 gear 6 WG 260: CAN-communication E/A-Modul 1 maximum participant-transmission cycle exceeded X45:25/26 U-51.1/51.2 E 1
TCU switches to "N" and uses emergency transmission switch; operation mode: normal
check E/A Modul, check lines from CAN-bus, check cable to E/A control device
967806 gear 6 WG 260: CAN-communication E/A-Modul 5 permanent error bus connection X45:25/26 U-51.1/51.2 E 1
967807 gear 6 WG 260: CAN-communication E/A-Modul 5 maximum participant-transmission cycle exceeded X45:25/26 U-51.1/51.2 E 1
TCU functions as an engine brake and exhaust flap brake is off; operation mode: normal
check engine control device, check line from CAN-bus, check cable to engine control device
967930 gear 6 WG 260: CAN-signal condition of auxiliary brakes defective/missing X45:25/26 U-51.1/51.2 E 1
no reaction; operation mode normal
check E/A Modul, check lines from CAN-bus, check cable to E/A control device
968130 gear 6 WG 260: CAN-signal of secondary output torque defective/missing X45:25/26 U-51.1/51.2 E 1
no reaction, TCU uses emergency secondary drive torque signal; operation mode normal
check E/A Modul, check lines from CAN-bus, check cable to E/A control device
002389508 242
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
968430 gear 6 WG 260: CAN-signal of engine output torque defective/missing X45:25/26 U-51.1/51.2 E 1
operation mode: control of emergency coupling
check E/A Modul, check lines from CAN-bus, check cable to E/A control device
968530 gear 6 WG 260: CAN-signal kickdown accelerator op. cab defective/missing X45:25/26 U-51.1/51.2 E 1
no reaction
check E/A Modul, check lines from CAN-bus, check cable to E/A control device
968630 gear 6 WG 260: CAN-signal engine brake exhaust flap defective/missing X45:25/26 U-51.1/51.2 E 1
TCU functions as an exhaust flap brake; operation mode: normal
check E/A Modul, check lines from CAN-bus, check cable to E/A control device
968830 gear 6 WG 260: CAN-signal shift selector E/A-Modul defective/missing X45:25/26 U-51.1/51.2 E 1
emergency program with emergency drive switch
969114 gear 6 WG 260: TCU frequency input 1 EF1 input speed short circuit to supply voltage X45:19/3 U-64.1/64.3 E 1
operation mode: control of emergency coupling
check cable TCU<->sensor, connector plug, positioning sensor, adjustment of positioning sensor
969133 gear 6 WG 260: TCU frequency input 1 EF1 input speed logic error X45:19/3 U-64.1/64.3 E 1
operation mode: control of emergency coupling
check cable TCU<->sensor, check connector plug, check speed sensor, check sensor distance
002389508 243
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
969141 gear 6 WG 260: TCU frequency input 1 EF1 input speed excessive speed X45:19/3 U-64.1/64.3 E 1
compulsory up-shifting disengaged
check engine (pick out recorded error from error memory), check speed sensor
969156 gear 6 WG 260: TCU frequency input 1 EF1 input speed open circuit or short circuit to ground X45:19/3 U-64.1/64.3 E 1
operation mode: control of emergency coupling
check cable TCU<->sensor, check connector plug, check speed sensor
969214 gear 6 WG 260: TCU frequency input 2 EF2 turbine speed short circuit to supply voltage X45:41/3 U-64.2/64.3 E 1
op.mode: control of emergency coupling, on output speed malf., TCU switches to "N", emergency travel func
check cable TCU<->sensor, check connector plug, check speed sensor
969233 gear 6 WG 260: TCU frequency input 2 EF2 turbine speed logic error X45:41/3 U-64.2/64.3 E 1
op.mode: control of emergency coupling, on output speed malf., TCU switches to "N", emergency travel func
check cable TCU<->sensor, check connector plug, check speed sensor
969256 gear 6 WG 260: TCU frequency input 2 EF2 turbine speed open circuit or short circuit to ground X45:41/3 U-64.2/64.3 E 1
op.mode: control of emergency coupling, on output speed malf., TCU switches to "N", emergency travel func
check cable TCU<->sensor, check connector plug, check speed sensor
969314 gear 6 WG 260: TCU frequency input 3 EF3 medium speed short circuit to supply voltage X45:42/3 U-64.3/64.3 E 1
operation mode: control of emergency coupling
check cable TCU<->sensor, check connector plug, check speed sensor
969333 gear 6 WG 260: TCU frequency input 3 EF3 medium speed logic error X45:42/3 U-64.3/64.3 E 1
operation mode: control of emergency coupling
check cable TCU<->sensor, check connector plug, check speed sensor
969356 gear 6 WG 260: TCU frequency input 3 EF3 medium speed open circuit or short circuit to ground X45:42/3 U-64.3/64.3 E 1
operation mode: control of emergency coupling
check cable TCU<->sensor, check connector plug, check speed sensor
969414 gear 6 WG 260: TCU frequency input 4 EF4 output speed short circuit to supply voltage X45:62/4 U-64.4/64.5 E 1
op.mode: control of emergency coupling, on turbine speed malf. TCU switches to "N", emergency drive program
check cable TCU<->sensor, check connector plug, check speed sensor
969433 gear 6 WG 260: TCU frequency input 4 EF4 output speed logic error X45:62/4 U-64.4/64.5 E 1
op.mode: control of emergency coupling, on turbine speed malf. TCU switches to "N", emergency drive program
check cable TCU<->sensor, check connector plug, check speed sensor
002389508 244
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
969456 gear 6 WG 260: TCU frequency input 4 EF4 output speed open circuit or short circuit to ground X45:62/4 U-64.4/64.5 E 1
op.mode: control of emergency coupling, on turbine speed malf. TCU switches to "N", emergency drive program
check cable TCU<->sensor, check connector plug, check speed sensor
969471 gear 6 WG 260: TCU frequency input 4 EF4 output speed speed signal implausible to other speeds X45:62/4 U-64.4/64.5 E 1
op.mode: control of emergency coupling, on turbine speed malf. TCU switches to "N", emergency drive program
check sensor signal of output speed-sensor, check cable from TCU<>sensor
969617 gear 6 WG 260: TCU internal voltage below required value X45 E 1
switches to "N"; operation mode: TCU-shut-down
check battery and alternator, check cable/connection terminals from battery to TCU
969636 gear 6 WG 260: TCU internal memory error EPROM or FLASH X45 E 1
002389508 245
Fehler-Nr. Fehlertext / Reaktion / Behebung Stecker Blatt K W
969651 gear 6 WG 260: TCU internal short circuit to supply voltage X45 E 1
969760 gear 6 WG 260: TCU logic error gear area signal X45 E 1
969761 gear 6 WG 260: TCU logic error directional selection signal X45 E 1
TCU switches transmission to "N"; operation mode: transmission shut-down
002389508 246