APH PERFORMANCE DATA

UNIT 5
DATE 2/25/2022 Time
GENERATION 103
CALCULATION
Description Units Rated(#1-6) Rated(#7-10)
Air leakage into APH system (%)-assumed AL 9 9
Temperature of the combustion air at inlet to APH (TAI) 0
C 35 35
Temperature of the combustion air at Outlet of APH (TAO) 0
C 280 273
Temperature of the flue gas at Outlet of APH (TGO) 0
C 130 119
Temperature of the Flue gas at Inlet of APH (TIN) 0
C 319 309

Corrected Flue gas Temperature out of APH (TGONI)


0
C 139 127
Effectiveness (Gas side efficiency) % 63.41 66.46

X-Ratio % 73.50 76.52


TGONI={AL X Cpa X (TGO – TAI)/(100 X Cpg)}+T GO

PUT DATA ONLY IN GREEN FIELDS


5
6:10 PM
MW

APH A APH B
15.00 15.00
36 25
251 247
122 148
303 301
135 167
62.75 48.46
77.93 60.25
O – TAI)/(100 X Cpg)}+T GO

IN GREEN FIELDS
LPH 1,2,3 PERFORMANCE DATA
UNIT 5
DATE 2/25/2022 Time 6:10 PM
GENERATION 103
Description Units Rated(#1-6) Rated(#7-10) LPH-1 LPH-2
Steam inlet pressure LPH-1/2/3  kg/cm2 0.37/0.80/2.3 0.3 0.8

Steam inlet sat temperature(Ts) LPH-1/2/3 o


C 73.53/92.96/124.06 68.64 92.96

Condensate inlet temperature(Ti) o


C 51/69.8/88.8 52 67

Condensate outlet temperature (To) LPH-


1/2/3
o
C 69.8/88.8/119.8 67 85

Drip temperature (Td) LPH-1/2/3 o


C 57/75.8/94.4 58 83

TTD of LPH-1/2/3(Ts-To) o
C 3.73/4.16/4.26 1.64 7.96

DCA of LPH-1/2/3 (Td-Ti) o


C 6.0/6.0/5.6 6 16

Condensate temperature gain LPH-1/2/3


(TR)=(To-Ti) 0C 18.8/19/31 15 18

ADD 1KSC TO GAUGE PRESSURE TO GET ABS PRESSURE


PUT DATA ONLY IN GREEN FIELDS
RATED VALUES ARE FOR 120 MW

COMMENTS: DRIP TEMP. OF LPH-03 IS SHOWING WRONG VALUE.(WR004587_19)


6:10 PM
MW
LPH-3
2.1

121.14

85

116

100

5.14

15

31
HPH 5 &6 PERFORMANCE DATA
UNIT 5
DATE 2/25/2022 Time 6:10 PM
GENERATION 103 MW
Description Units Rated(#1-6) Rated(#7-10) HPH-5 HPH-6
Steam inlet pressure HPH-5/6  kg/cm2 12.15/30.4 13.58/35.4 12.4 29.2

Steam inlet sat temperature(Ts) HPH-5/6 o


C 187.6/233.07 192.7/242.13 188.56 231.29

Feed water inlet temperature(Ti) o


C 152.4/187.6 150/190 146 171

Feed water outlet temperature (To) HPH-


5/6
o
C 187.6/233.5 190/240 171 202

Drip temperature (Td) HPH-5/6 o


C 158.4/193.6 167/204 150 180

TTD of HPH-5/6(Ts-To) o
C 0/-0.43 2.63/2.03 17.56 29.29

DCA of HPH-5/6 (Td-Ti) o


C 6.0/6.0 17/14 4 9

FW temperature gain HPH-5/6 (TR)=(To-Ti) 0


C 35.2/45.9 40/50 25 31

ADD 1KSC TO GAUGE PRESSURE TO GET ABS PRESSURE


PUT DATA ONLY IN GREEN FIELDS
RATED VALUES ARE FOR 120 MW
CONDENSER PERFORMANCE DATA
UNIT 5
DATE 2/25/2022 Time
GENERATION 103
Description Units Rated(#1-6) Rated(#7-10)
CW inlet temperature (Ti) o
C 34 36

CW outlet temperature(To) o
C 41 42.96

Condenser vacuum  kg/cm2 0.9127 0.9127

Condenser Pressure(absolute)  kg/cm2 0.1033 0.1033

Saturation temperature Ts (from steam table) o


C 46.1 46.1

Hot well temperature(at inlet of running CEP) o


C 45.1 45.1
Thw

Ejector suction air temperature Tej o


C >41 >41

ΔT of Cooling water (To-Ti) o


C 7 6.96

Initial temperature difference (Ts-Ti) o


C 12.1 10.76

Terminal temperature difference(TTD) Ts-To o


C 5.1 3.8
Condensate sub cooling (Ts- Thw) o
C 1.0 1.0
Air offtake temperature (Ts-Tej) o
C 5.1 5.1

Condenser effectiveness (To-Ti)/(Ts-Ti) 0.58 0.64

PUT DATA ONLY IN GREEN FIELDS

RATED VALUES ARE FOR 120 MW


A
5
6:10 PM
MW
Condenser Performance
32

40

0.888

0.1280

50.32

46.6

43.6

18.32

10.32
3.72
6.72

0.44